Himachal Pradesh Irrigation And Public Health Department Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date25 Jun 2024
Closing DateCancelled
Tender Amount₹ 3,42,76,789 
Notes
Download

Costs

Summary

Construction Of Lift Irrigation Scheme Dallang And Thorang In Gp Gondhla Distt L S Hp

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Foundation & plinth

3.09

-

-

... More
Columns, pillars, posts and strus

24.7

-

-

... More
Providing and laying cement concrete 1:4:8(1 Cement :4 sand: 8 graded stone aggregate 40mm nominal size) and curing complete excluding the cost of form work foundation and plinth in all leads and lifts

105.78

-

-

... More
Providing & Laying cement concrete 1:6:12 ( 1 cement : 6 sand : 12 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth within all leads and lifts as per satisfaction and direction of Engineer-in-charge.

1.66

-

-

... More
Random Rubble Masonary With Hard Stone In Foundation & Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement: 6 Coarse Sand: 12 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level With Cement Mortar 1:6 (1 Cement:6 Coarse Sand). within all leads and lifts as per satisfaction and direction of Engineer-in-charge.

202.36

-

-

... More
Providing and laying cement concrete 1:1.5:3 ( 1 Cement : 1.5 sand : 3 gareded stone aggregate 20 mm & down guage nominal size and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :

-

-

-

... More
Foundation, footing, bases of columns and the like and the mass concrete.

92.68

-

-

... More
Wall (any thickness, but not less than 0.10 mtr. thickness) attached pilasters, buttresses, plinth & string courses etc. from top of foundation level upto floor two level

99.99

-

-

... More
Suspended floor roofs landing shelves

10.17

-

-

... More
Columns, pillars, posts and strus

4.86

-

-

... More
Providing form work of steel plate 3.15mm thick planking so as to give a rough finish including shuttering centering, shuttering and propping height of propping and centering below supporting floor to ceilling not exceeding 4 mtr and removal of same for in-situ reinforced concrete and plain concrete work in lintels beams etc. including all leads and lifts

-

-

-

... More
Foundation,footing, bases of columns and the like and the mass concrete.

46.6

-

-

... More
Vertical surfaces such as walls (any thickness), partition and the like including atteched plasters, buttress, plinth and string cources and the like,( inner sides).

1483.22

-

-

... More
Flat surfaces such as soffits o and suspended flors, roofs, landing and like : floor upto 200 mm in thickness.

6.88

-

-

... More
Columns, pillars, posts and strus

71.25

-

-

... More
Beam Cantiliver

93.63

-

-

... More
Providing mild/tor steel reinforcement for RCC Work i/c, bending binding placing in possition complete up to floor two level (Tor-steel)

21474.52

-

-

... More
Laying and jointing of G.I pipe in trenches I/c earth work complete for inlet , outlet and scour pipe (LR)

-

-

-

... More
100mm dia (MC)

252

-

-

... More
Laying and jointing of G.I pipe in trenches I/c earth work complete for inlet , outlet and scour :- (LR)

-

-

-

... More
150mm dia (MC)

72

-

-

... More
Prov .and fixing C.I. Sluice valve (with hand wheel) as per IS;780 Class upto 300 mm dia (including brass spindle and as per IS:2906 class II for diameters more than 300 mm complete with bolts, nuts, rubber insertion etc,(The tail pieces if required shall be measured and paid for separately)

-

-

-

... More
100 mm diameter Class PN-1.0 for inlet, outlet and scour :

42

-

-

... More
Prov .and fixing C.I. Sluice valve (with hand wheel) as per IS;780 Class upto 300 mm dia (including brass spindle and as per IS:2906 class II for diameters more than 300 mm complete with bolts, nuts, rubber insertion etc,(The tail pieces if required shall be measured and paid for separately)

-

-

-

... More
150 mm diameter for inlet, outlet and scour :

12

-

-

... More
Providing 200mm wide cast iron rungs with chequered or ribbed non slip surface including fixing in manholes with 200x200x100mm cement concrete 1:3:6 (1 cement :3 sand :6graded stone aggregate 20mm nominal size.)

56

-

-

... More
Brick Work In Cement Mortar 1:4 (1 Cement:4 Coarse Sand) With Common Burnt Clay F.P.S (Non-Modular) Bricks Of Class Designation 7.5 In Foundation & Plinth complete in all respect as per direction of Engineer -in - Charge

55.32

-

-

... More
Providng Stone soling properly hand packed tightly as hand packed under floor within all leads and lifts as per satisfaction and direction of Engineer-in-charge.

56.92

-

-

... More
Half brick work using common burnt clay building bricks (iind class) in super structure above plinth level upto flooe two level in cement mortar1 :4 ( 1cement : 4 sand)

7.65

-

-

... More
Wire crates of GI wire filled with boulders with square cut faces against the wire. (Wire crates to be measured and paid for separately)

1312.5

-

-

... More
Wire crates made of GI Wire filled with boulders with square cut faces against the wire. (Boulder filling to be measured and paid for separately) Interlink chain 5mm thick corresponding to SWG-8. 15cmx15cm mesh.

4650

-

-

... More
Providing and fixing compound gate of size 1350x900 mtrs. on ISMC channel of 75x75mm (1.96 mtr.long over all) with hinges including gate of angle iron 40x40x2mm for horizontal and vertical incluidng fixing the gate with hold fast flat 40x40x2mm within all leads and lifts as per satisfaction and direction of Engineer-in-charge.

1

-

-

... More
Providing and fixing of fencing Panel of size 1.80 x 1.20 of jali 25x25mm mesh welded to M.S. black tube 32mm dia of 14 gauge with M.S. flat cover 20x3mm, M.S. hold fasts 4 Nos (min.) made out of M.S. flat 32x5mm as per direction on Engineer-in-charge.

84

-

-

... More
Providing wood work in frames of doors,windows, clerestory windows and other frames wrought, framed and fixed in position 2nd class deodar wood .

1.74

-

-

... More
Providing and fixing panelled glazed or panelled and glazed shutters for doors, windows and clerestory windows. including bright finished / black enamelled iron but hings with necessary screws 45mm thick in 2nd class deodar wood.

32.31

-

-

... More
Providing and fixing wire gauge shutters using galvanised M.S.wire gauge of I.S gauge designation 85 G with wire of dia 0.56mm for doors windows and clerestory windowsincluding bright finished black enamelled iron hinges with necessary screws 40mm thick Ist class deodar wood.

22.32

-

-

... More
15 mm cement plaster in single coat on rough side of brick/stone masonry for interior plastering upto floor two level including arises, internal rounded angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:3

314.37

-

-

... More
6mm thick cement plaster in 1 : 3 (1cement 3 sand) . Finished with a floating coat of neet cement and thick coat lime brush on top of wall when dry for bearing of RCC slab and beams.

64.67

-

-

... More
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surfare even and smooth complete

379.04

-

-

... More
Distempering (two coats) with oil bound washable distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and including a priming coat with distemper primer of approved brand and manufacture after thoroughly brushing the surface free from mortar droppings and other foreign matter and also including preparing the surface even and sand papered smooth Priming coat with distemper primer.

379.04

-

-

... More
APPLYING PRIMING COAT WITH READY MIXED PINK OR GREY PRIMER OF APPROVED BRAND & MANUFACTURE ON WOOD (HARD & SOFT WOOD) COMPLETE IN ALL RESPECT WITHIN ALL LEADS & LIFTS AS PER THE DIRECTION & TO THE ENTIRE SATISFACTION OF THE ENGINEER-IN-CHARGE.

100.17

-

-

... More
PAINTING WITH OIL TYPE WOOD PRESERVATIVE OF APPROVED BRAND & MANUFACTURE IN NEW WORK (TWO OR MORE COATS) COMPLETE IN ALL RESPECT WITHIN ALL LEADS & LIFTS AS PER THE DIRECTION & TO THE ENTIRE SATISFACTION OF THE ENGINEER-IN-CHARGE.

100.17

-

-

... More
PROVIDING & FIXING 125 x 65 x 2.12 MM ISI MARKED MS PRESSED BUTT HINGES BRIGHT FINISHED WITH NECESSARY SCREWS ETC. COMPLETE IN ALL RESPECT WITHIN ALL LEADS & LIFTS AS PER THE DIRECTION & TO THE ENTIRE SATISFACTION OF THE ENGINEER-IN-CHARGE.

30

-

-

... More
PROVIDING & FIXING 75 x 47 x 1.70 MM ISI MARKED MS PRESSED BUTT HINGES BRIGHT FINISHED WITH NECESSARY SCREWS ETC. COMPLETE IN ALL RESPECT WITHIN ALL LEADS & LIFTS AS PER THE DIRECTION & TO THE ENTIRE SATISFACTION OF THE ENGINEER-IN-CHARGE.

30

-

-

... More
PROVIDING & FIXING 150 x 10 MM ISI MARKED OXIDIZED MS TOWER BOLT BLACK FINISH (BARREL TYPE) WITH NECESSARY SCREWS ETC. COMPLETE IN ALL RESPECT WITHIN ALL LEADS & LIFTS AS PER THE DIRECTION & TO THE ENTIRE SATISFACTION OF THE ENGINEER-IN-CHARGE.

102

-

-

... More
PROVIDING & FIXING ISI MARKED 125 MM OXIDIZED MS HANDLES CONFORMING TO IS:4992 WITH NECESSARY SCREWS ETC. COMPLETE IN ALL RESPECT WITHIN ALL LEADS & LIFTS AS PER THE DIRECTION & TO THE ENTIRE SATISFACTION OF THE ENGINEER-IN-CHARGE.

74

-

-

... More
PROVIDING & FIXING 250 x 16 MM ISI MARKED OXIDIZED MS SLIDING DOOR BOLTS WITH NUTS & SCREWS ETC. COMPLETE IN ALL RESPECT WITHIN ALL LEADS & LIFTS AS PER THE DIRECTION & TO THE ENTIRE SATISFACTION OF THE ENGINEER-IN-CHARGE.

5

-

-

... More
40 MM THICK CEMENT CONCRETE FLOORING 1:2:4 (1 CEMENT: 2 COARSE SAND: 4 GRADED STONE AGGREGATE 20 MM NOMINAL SIZE) FINISHED WITH A FLOATING COAT OF NEAT CEMENT, INCLUDING CEMENT SLURRY, BUT EXCLUDING THE COST OF NOISING OF STEPS ETC. COMPLETE IN ALL RESPECT WITHIN ALL LEADS & LIFTS AS PER THE DIRECTION & TO THE ENTIRE SATISFACTION OF THE ENGINEER-IN-CHARGE.

62.36

-

-

... More
MAKING PLINTH PROTECTION 50 MM THICK OF CEMENT CONCRETE 1:3:6 (1 CEMENT:3 COARSE SAND:6 GRADED STONE AGGREGATE 20 MM NOMINAL SIZE) OVER 75 MM THICK BED OF DRY BALLAST 40 MM NOMINAL SIZE, WELL RAMMED & CONSOLIDATED & GROUTED WITH FINE SAND, INCLUDING NECESSARY EXCAVATION, LEVELLING & DRESSING & FINISHING TOP SMOOTH COMPLETE AS DIRECTED BY THE ENGINEER-IN-CHARGE.

25.61

-

-

... More
PROVIDING 40 x 3 MM FLAT IRON HOLD FAST 40 MM LONG INCLUDING FIXING TO FRAME WITH 10 MM DIAMETER BOLTS NUTS & WOODEN PLUGS & EMBEDING IN CEMENT CONCRETE BLOCK 30 x 10 x 15 CM. 1:3:6 (1 CEMENT: 3 SAND: 6 GRADED STONE AGGREGATE 20 MM NOMINAL SIZE) COMPLETE IN ALL RESPECT WITHIN ALL LEADS & LIFTS AS PER THE DIRECTION & TO THE ENTIRE SATISFACTION OF THE ENGINEER-IN-CHARGE.

120

-

-

... More
STRUCTURAL STEEL RIVETED, BOLTED OR WELDED IN BUILT UP SECTIONS, TRUSSES & FRAMED WORK INCLUDING CUTTING, HOISTING, FIXING IN POSITION & APPLYING A PRIMING COAT OF APPROVED STEEL PRIMER COMPLETE IN ALL RESPECT WITHIN ALL LEADS & LIFTS AS PER THE DIRECTION & TO THE ENTIRE SATISFACTION OF THE ENGINEER-IN-CHARGE. & as per detailed designs.

2981.33

-

-

... More
Providing and fixing 0.60mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5 microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia metre with prepainted limpet and rubber washers complete with all accesoriees as required as per the direction of Engineer-in-charge.

296.88

-

-

... More
Supplying and fixing rolling shutters of approved make made of 80 mm X 1.25mm M.S laths interlocked together through their entire length and joined together at the end by end locks mounted on ITEM CODE DESCRIPTION UNIT QTY. RATE COST REMARKS Steel Work specially designed pipe shaft,with brackets side guides and arrangements for inside and outside locking with push pull operation complete but excluding the of the top cover and spring.

7.5

-

-

... More
PROVIDING & FIXING WHITE VITREOUS CHINA PEDESTAL TYPE WATER CLOSET (EUROPEAN TYPE W.C PAN) WITH ISI MARKED BLACK SOLID PLASTIC SEAT & LID, 10 LITRE LOW LEVEL WHITE P.V.C FLUSHING CISTERN, INCLUDING FLUSH PIPE, WITH MANUALLY CONTROLLED DEVICE (HANDLE LEVER) CONFORMING TO IS:7231, WITH ALL FITTINGS & FIXTURES COMPLETE, INCLUDING CUTTING & MAKING GOOD THE WALLS & FLOORS WHEREVER REQUIRED COMPLETE IN ALL RESPECT AS SPECIFIED & DIRECTED BY ENGINEER-IN-CHARGE.

1

-

-

... More
PROVIDING & FIXING WHITE VITREOUS CHINA ORISSA PATTERN WATER CLOSET SQUATTING PAN (INDIAN TYPE W.C PAN) OF SIZE 580 x 440 MM WITH INTEGRAL TYPE FOOT RESTS WITH 100 MM SAND CAST IRON P OR S TRAP, 10 LITRE LOW LEVEL WHITE P.V.C FLUSHING CISTERN, INCLUDING FLUSH PIPE, WITH MANUALLY CONTROLLED DEVICE (HANDLE LEVER) CONFORMING TO IS:7231, WITH ALL FITTINGS & FIXTURES COMPLETE, INCLUDING CUTTING & MAKING GOOD THE WALLS & FLOORS WHEREVER REQUIRED COMPLETE IN ALL RESPECT AS SPECIFIED & DIRECTED BY ENGINEER-IN-CHARGE.

1

-

-

... More
Provoding & Fixing flat back wall urinals of standard make i.e Cera/Hindware i/c required accessories complete in all respect with in all leads and lifts and to the entire satisfaction of Engineer -in- charge

1

-

-

... More
PROVIDING & FIXING WHITE VIREOUS CHINA WASH BASIN WITH C.I BRACKETS OF SIZE 515 x 410 MM WITH A PAIR OF 15 MM C.P BRASS PILLAR TAPS, 32 MM C.P BRASS WASTE OF STANDARD PATTERN, INCLUDING PAINTING OF FITTINGS & BRACKETS, CUTTING & MAKING GOOD THE WALLS WHEREVER REQUIRED COMPLETE IN ALL RESPECT AS SPECIFIED & DIRECTED BY ENGINEER-IN-CHARGE.

1

-

-

... More
PROVIDING & FIXING STAINLESS STEEL A ISI 304 (18/8) KITCHEN SINK single bowl SIZE 455x405 MM BOWL DEPTH 203 MM AS PER IS:13983 WITH C.I BRACKETS & STAINLESS STEEL PLUG 40 MM, INCLUDING PAINTING OF FITTINGS & BRACKETS, CUTTING & MAKING GOOD THE WALLS WHEREVER REQUIRED COMPLETE IN ALL RESPECT AS SPECIFIED & DIRECTED BY ENGINEER-IN-CHARGE.

1

-

-

... More
Providing and fixing PVC waste pipe 32mm nominal dia for wash basin and sink ISI mark of reputed make within all leads and lifts and to entire satisfaction of Engineer-in-charge.

2

-

-

... More
Providing and fixing M.I. Union for wash basin or sink with in all leads and lifts as per direction of Engineer-in- Charge

2

-

-

... More
Providing and fixing 450x600mm bevelled edge mirror of reputed make mounted on AC sheet and fixed with brass screws with in all leads and lifts.as per direction of Engineer-in- Charge

2

-

-

... More
Providing chromium plated brass soap dish with brass bracket of reputed make within all leads and lifts and to entire satisfaction of Engineer-in-charge.

4

-

-

... More
PROVIDING & FIXING 15 MM NOMINAL BORE C.P BRASS ANGLE VALVE FOR BASIN MIXER & GEYSER POINTS OF APPROVED QUALITY CONFORMING TO IS:8931 ALL COMPLETE AS SPECIFIED & DIRECTED BY THE ENGINEER-IN-CHARGE.

6

-

-

... More
Providing and fixing PVC connection 15mm of superior quality within all leads and lifts and to entire satisfaction of Engineer-in-charge.

2

-

-

... More
Providing and fixing PVC floor trap of self cleaning design including fixing with approved adhesive cost of cutting and making good the wall and floors etc. complete.

-

-

-

... More
110x75mm

4

-

-

... More
PROVIDING & FIXING 15 MM NOMINAL BORE C.P BRASS BIB COCK OF STANDARD DESIGN & OF APPROVED MAKE CONFORMING TO IS:8931 ALL COMPLETE AS SPECIFIED & DIRECTED BY THE ENGINEER-IN-CHARGE..

5

-

-

... More
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R lain & brass threaded polypropylene andom fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in- Charge

-

-

-

... More
Poly propylene- Random- Co- Polymer (PPR) pipes PN- 16(SDR 7.4) - 20 mm Outer Dia

60

-

-

... More
Poly propylene- Random- Co- Polymer (PPR) pipes PN- 16(SDR 7.4) - 25 mm Outer Dia

90

-

-

... More
PROVIDING & FIXING 110 MM OUTER DIA PVC PIPES OF 6 KG/CM2 WORKING PRESSURE INCLUDING FITTINGS ALL COMPLETE AS SPECIFIED & DIRECTED BY THE ENGINEER-IN-CHARGE.

-

-

-

... More
110 mm dia

30

-

-

... More
75 mm dia

60

-

-

... More
Providing and fixing PVC door bend ISI mark of reputed make within all leads and lifts and to entire satisfaction of Engineer-in-charge.

-

-

-

... More
a) Door bend 110 mm dia

2

-

-

... More
b) Door bend 75 mm dia

4

-

-

... More
Providing and fixing PVC Plain bend ISI mark of reputed make within all leads and lifts and to entire satisfaction of Engineer-in-charge.

-

-

-

... More
a) Plain bend 110 mm dia

4

-

-

... More
a) Plain bend 75 mm dia

4

-

-

... More
PROVIDING & PLACING ON TERRACE (AT ALL FLOOR LEVELS) POLYETHYLENE WATER STORAGE TANK, IS:12701 MARKED, WITH COVER & SUITABLE LOCKING ARRANGEMENT & MAKING NECESSARY HOLES FOR INLET, OUTLET & OVERFLOW PIPES BUT WITHOUT FITTINGS & THE BASE SUPPORT FOR TANK ALL COMPLETE AS SPECIFIED & DIRECTED BY THE ENGINEER-IN-CHARGE.

1000

-

-

... More
wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface/recessed PVC conduit with modular switch, modular plates suitable GI box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required (i) Group C

30

-

-

... More
Supplying and drawing 2x 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface/recessed PVC conduit alongh with 1 no 4 sqmm 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required

300

-

-

... More
Supplying and drawing 2x 2.50 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface/recessed PVC conduit alongh with 1 no 2.50 sqmm 2.50 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required

210

-

-

... More
Supplying and drawing 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.

36

-

-

... More
Supplying & fixing following size modular base and cover plate on the existing modular metal boxes as required:-

-

-

-

... More
Modular base and cover plate, 12 module (200mmx150mm)

12

-

-

... More
Modular base and cover plate, 8 modules (125mmx125mm)

12

-

-

... More
Modular base and cover plate, 6 module (200mmx75mm)

4

-

-

... More
Supplying and fixing following rating modular switch/ socket in the existing switch box/ cover plate including connections etc. as required

-

-

-

... More
(i) S.P. 5/6 Amps one way Modular switch

40

-

-

... More
(iv) S.P. 15/16 Amps one way Modular switch

12

-

-

... More
(iv) 3 pin 5/6 Amps Modular socket outlet

20

-

-

... More
(v) 6 pin 15/16 Amps Modular socket outlet

10

-

-

... More
Supplying and fixing ceiling rose on the existing junction box/ wooden block including connections etc as required

6

-

-

... More
Supplying and fixing bakelite batten/ angle holder including connections etc. as required

6

-

-

... More
Supplying and eraction of 6 amps to 32 amps rating , 10KA breaking capacity 240 volts C curves, miniture circuit breaker of following poles in existing MCB DB complete with connections etc. as required

20

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator

1

-

-

... More
Providing installation of exhaust fan of following sizes in existing opening. including making the hole to suit the size of the above fan , making good the damages , connections , testing and commissioning etc. as required (i) Exhaust fan light duty ( Domestic) 300mm sweep

3

-

-

... More
Supplying eraction testing and commissioning of LED 18w retrofit tube made of extruded aluminium fitted with diffuser SYSKAA CAT No SSK-RA1801

15

-

-

... More
Supplying and fixing following rationg, double pole ( single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a senstivity current up to 300 miliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required (i) 63 Amp Cat-A

1

-

-

... More
Supplying errection, testing and commissioning of LED Bulb 12w of standard make i.e MAYFAIR BAJAJ/ HAVELL'S / SYSKA/ etc.

18

-

-

... More
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:-

5

-

-

... More
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. ( but without charcoal or coke and salt ) complete as required.

1

-

-

... More
Supplying and laying 8 SWG Copper wire at 0.50 mtr. below ground level for earth electrode conductor, including soldering etc. as required.

25

-

-

... More
Laying jointing and testing of Galvanised mild steel tubes ( GI pipe) of following diameter confirming to IS:1239-1990( latest with up to date ammendments) wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, provinding and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube during welding or otherwise shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately). (LR) 5% flanged.

-

-

-

... More
Raw Water Stage LIS Dallang :- GMS tube IS: 1239:2012 (MC) 125mm dia 4.8mm thickness Flange Table 17 (Rising main)

9

-

-

... More
Raw Water Stage LIS Thorang :- GMS tube IS: 1239:2012 (MC) 125mm dia 4.8mm thickness Flange Table 17 (Rising main)

8

-

-

... More
Main stage LIS Dallang:- GMS tube IS: 1239: 2012 125mm dia 4.8mm thickness Flange Table 28 (Rising main)

53

-

-

... More
Main stage LIS Thorang:- GMS tube IS 1239: 2012 (MC) 125 mm dia 4.8 mm thickness flange tabke 28 (rising main)

60

-

-

... More
Laying jointing (by way of circumferntial butt welding joints by electric arc welding ) and testing of Galvanised mild steel tubes ( GI pipe) of following diameter confirming to IS:1239-1990( latest with up to date ammendments) having minimum wall thickness as per IS code with bevelled/ plain ends in a random lengtth of 4 to 7 meters , including manufacturing reducers/ tapers, all short pices bends etc and class of pipes specified below, provided and jointe as per site requirement made from parent tubes. including lowering and laying in excavated trenches to ensure required level including flushing , cleaning and hydraulic testing complete in all respect to the satisfaction of engineer in charge . the fabricated bends shall have three or four cuts having its radius not less then five times the dia of pipe . the damaged portion of the pipes and specials made from the parant tube during welding or otherwise shall be provided anticorrosive treatment by applying two coats of anticorrosive bitumenous paint over a primming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately). (LR) 95% Butt welding

-

-

-

... More
Raw Water Stage LIS Dallang :- GMS tube IS: 1239:2012 (MC) 125mm dia 4.8mm thickness (Rising main)

171

-

-

... More
Raw Water Stage LIS Thorang:- GMS tube IS: 1239:2012 (MC) 125mm dia 4.8mm thickness (Rising main)

142

-

-

... More
Main stage LIS Dallang:- GMS tube IS: 1239:2012 (MC) 125mm dia 4.8mm thickness Flange 0 (Rising main)

997

-

-

... More
Main stage LIS Thorang:- GMS tube IS: 1239:2012 (MC) 125mm dia 4.8mm thickness Flange 0 (Rising main)

1140

-

-

... More
Providing Butt welding, laying and testing to levelled grades, IS marked Galvanised MSERW Pipes beveled ended of following dia mtr. / specifications confirming ISO:3183 ( with upto date amendments ) of steel grades L-290,X-42 jointing the pipes with butt welding at both end according to relevant BIS standards / approved specifications including manufacturing reducers/ tapers all short pieces , and bends as per site requirements and made from parent tubes ( to be measured and paid along with pipes ). Bends shall be manufactured in such a way that not more than 11-1/4 degree deflection is caused by a single cut and internal dia is not reduced including hydraulic testing to the entire satisfaction of Engineer-in -charge. The pipes and specials shall have in factory galvanized coating as per IS :4739 ( with latest amendments ) . The damaged portion of galvanization due to welding shall be provided with anticorrosive treatment by applying two coats of bituminous paint over priming coat as per AWWA specification C-203-1978 ( Earth work to be measured & paid for separately) 95% Butt welding.

-

-

-

... More
Main Stage LIS Thorang:- MSERW Pipe L-290, X- 42 125 mm dia 4.8 mm thickness (Rising main)

570

-

-

... More
Providing , laying, fixing, jointing and testing in trenches MSERW pipe (ISO:3183) of following dia meters confirming to steel grades L-290,X-42 (latest with upto date amendments) steel grade- A having wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, provinding and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately). 5% flanged.

-

-

-

... More
Main Stage LIS Thorang:- MSERW Pipe L-290, X- 42 125 mm dia 4.8 mm thickness Flange Table 28 (Rising main)

30

-

-

... More
Providing , laying , jointing and testing of HDPE pipes in trenches to required grades as per IS: 4984-2016 latest with up to date amendments of following dia and working pressure rating pipes, material grade and class of pipes. The jointing of pipes should be done by way of butt fusion welding as per relevant IS Code and specifications including all fittings and accessories e.g. coupling, TEE's, bends, reducers, screwed adopters, flanged tail pieces etc. complete in all respect as per direction of Engineer- in-charge.

-

-

-

... More
HDPE Pipe 140 mm (OD)PE-80, PN-4 as per (IS : 4984-2016)

3100

-

-

... More
Schedule -A1 Raw water stage LIS Dallang :- Providing suitable submersible pumpset of ( KSB/Kalama/Kirlosker/Johnston/Cromption?BS) or any other approved make confirming to IS latest suitable for lifting raw water (Latest with up to date ammendments) fitted with bronze impellers/ suitable alloy directly coupled to squirrel cage electrical induction motor of same make as (manufecturer standar) confirming to IS (Latest with up to date ammendments and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand verticals loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard, errection clamps, cable clips & depth Gauge et. . The power of electric motor should be atleast 10% in excess of the maximum power required by the pump inth operation range of(+) 10% and (-15%) of duty point head. the motor /motors confirming to minimum IE2 norms IS-12615/2011 with up to date ammendments. it should include cost of bearing nuts, bolts and pointings etc. The pump set should be capable to perform the following duties:- Discharge (Q) 7.34 LPS for each pump. Total Dynamic head:- 26.26 meter a) LWL in sump well (h) 2918 meter b) Shaft level 2916 meter c) Level at discharge point 2938 meter d) Suction lift -ve 2 meter e) Dynamic head 26.26 meter f) Static head 22.000 meter Rising main a) Length 180 meter b) Dia 125mm Pumping hours 20 hours Altitude of installation above MS 2916 meter Characterstics of water Clear water with turbidity up to 50PPM. a) Temperature 18 degree centigrade.

2

-

-

... More
Providing control panel as per KSB specifications and having protection of motor on occurance of faults { Triping on occurance of fault(s) i.e. Moisture, high motor temperature, dry running, reverse rotation, Single phasing, voltage imbalance, overload and short circuit } and indiation thereof by glowing fault lamp ; for motors above 30 KW another protection of Mechanical seal failure shall also be provided in addition to above protections; fitted with following components:- (83.01) Powder coated steel sheet fabricate enclosure of suitable size to accommodate the following accessories:- (83.02) Shnider /L&T/Havells/Standard make MCCB in MAINS on incomer side (83.03) Shnider/ Siemens make phase indicating lamps (83.04) Logestic or similar superior make 300VA transformer (83.05) Conzerv make digital VAF meter having direct digital display of Ampere, Voltage and frequency with selector switch and CTs where ever required (all perameters displaying in one meter only ) (83.06) AUTO/MANUAL switch Salzer/L&T/kaycee make (83.07) 3 Nos CONTACTORS of Spercher+ Schuh /L&T/Schnider /BCH/Siemens make, for star delta starting (83.08) Over load relay (83.09) STAR-DELTA TIMER ( for pumpset above 7.5HP) (83.10) SINGLE PHASING PREVENTOR (83.11) ON/TRIP INDICATING LIGHTS Schnider/ Siemens /L&T make (83.12) CONTROL MCB Schnider/ Havells/Standard/Siemens/ Legrand make (83.13) PUSH BT. Schnider/Siemens/L&T make (83.14) TERMINALS Phonix make (83.15) RCCB of Legrand/Siemens/Havells / L&T/ Standard make (83.16) Hour run meter of CE/Kaycee make

2

-

-

... More
Providing Double flanged Leader / Pelican /Kirloskar make Cast iron Sluice Valve in delivery side conf. to Class IS 780 PN 1.0; one size higher than delivery outlet size of pump

2

-

-

... More
Providing Double flanged Leader / Pelican /Kirloskar make Cast iron Swing check type Reflux Valve in delivery side conf. to Class IS 780 PN 1.0; one size higher than delivery outlet size of pump .

2

-

-

... More
Prov. and laying PVC Insulated armoured copper conductor cable Havells/Gloster/Khaitan make of suitable size and suitable for motor offered under item No I complete with flexible pipe and couplers from HPSEB meter to Panel, switch, starter complete job, The type and size shall be subject to approval of Electrical authorities and in case of its non acceptance the same shall be replaced free of cost by the tenderer

-

-

-

... More
Supply side : …………..mm^2

1

-

-

... More
Prov. and laying PVC Insulated round copper conductor cable of suitable size suitable for motor offered under item No 50 complete having suitable cores to fulfill requirement of star delta starter and protection/ controls from panel to motor 10 mtr cable per set shall be supplied free of cost ( cost inclusive in cost of pumpset) additional length shall be measured and to paid separately . Cost be quated for additional length over and above free cable of 10 Mtr/pumpset.

-

-

-

... More
Motor side : …………………. mm^2

1

-

-

... More
Providing Double flanged Leader / Pelican /Kirloskar make Cast iron Swing check type Reflux Valve in delivery side conf. to Class IS 5312 PN 1.0; equal to dia of rising main i.e. 125mm dia

1

-

-

... More
Providing 100 mm dial pressure guage of Fiebig/Bourden make having range 0-7 Kg/cm^2 with copper tubing, stop cock and allied access.as per IS 3624 - 1987 latest with up to date amendments

2

-

-

... More
Providing and fixing GMS/ MSERW pipe of suitable size as detailed here under for delivery and common header complete in all respects with all specials like bends, tees, reducers, increasers, companion flanges including rubber/ asbestos gaskets of minimum 3 mm thickness as per IS 1364-1983. The pipes shall be as per relevant IS Code, the flanges shall be of compatible with Pumps, valves etc and suitable for withstanding 1.5 times the working pressure likely to be induced as stipulated against item No I above

-

-

-

... More
Delivery side 125 mm Dia. GMS (MC)

10

-

-

... More
L&T/Havells make shunt capacitor of suitable rating conf. to IS 2834-1986 latest with up to date amendments to raise power factor at site from 0.85 to 0.95, complete with required cable for direct connection to control panel and fittings.

2

-

-

... More
Supply of cable for water level guard

1

-

-

... More
Supply of supporting clamps

1

-

-

... More
Supply of cable clips of required size

1

-

-

... More
Erection of all equipments from Sr No 1 to 12 including cost of tee's bends, tappers and any other required fitting as per site condition and directions of engineer In charge.

1

-

-

... More
Schedule-A2 :- Raw Water Stage LIS Thorang :- Providing suitable submersible pumpset of ( KSB/Kalama/Kirlosker/Johnston/Cromption?BS) or any other approved make confirming to IS latest suitable for lifting raw water (Latest with up to date ammendments) fitted with bronze impellers/ suitable alloy directly coupled to squirrel cage electrical induction motor of same make as (manufecturer standar) confirming to IS (Latest with up to date ammendments and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand verticals loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard, errection clamps, cable clips & depth Gauge et. . The power of electric motor should be atleast 10% in excess of the maximum power required by the pump inth operation range of(+) 10% and (-15%) of duty point head. the motor /motors confirming to minimum IE2 norms IS-12615/2011 with up to date ammendments. it should include cost of bearing nuts, bolts and pointings etc. The pump set should be capable to perform the following duties:- Discharge (Q) 7.34 LPS for each pump. Total Dynamic head:- 21.38 meter a) LWL in sump well (h) 2921 meter b) Shaft level 2918 meter c) Level at discharge point 2938 meter d) Suction lift -ve 3 meter e) Dynamic head 21.38 meter f) Static head 20.000 meter Rising main a) Length 150 meter b) Dia 125mm Pumping hours 20 hours Altitude of installation above MS 2918 meter Characterstics of water Clear water with turbidity up to 50PPM. a) Temperature 18 degree centigrade.

2

-

-

... More
Providing control panel as per KSB specifications and having protection of motor on occurance of faults { Triping on occurance of fault(s) i.e. Moisture, high motor temperature, dry running, reverse rotation, Single phasing, voltage imbalance, overload and short circuit } and indiation thereof by glowing fault lamp ; for motors above 30 KW another protection of Mechanical seal failure shall also be provided in addition to above protections; fitted with following components:- (97.01) Powder coated steel sheet fabricate enclosure of suitable size to accommodate the following accessories:- (97.02) Shnider /L&T/Havells/Standard make MCCB in MAINS on incomer side (97.03) Shnider/ Siemens make phase indicating lamps (97.04) Logestic or similar superior make 300VA transformer (97.05) Conzerv make digital VAF meter having direct digital display of Ampere, Voltage and frequency with selector switch and CTs where ever required (all perameters displaying in one meter only ) (97.06) AUTO/MANUAL switch Salzer/L&T/kaycee make (97.07) 3 Nos CONTACTORS of Spercher+ Schuh /L&T/Schnider /BCH/Siemens make, for star delta starting (97.08) Over load relay (97.09) STAR-DELTA TIMER ( for pumpset above 7.5HP) (97.10) SINGLE PHASING PREVENTOR (97.11) ON/TRIP INDICATING LIGHTS Schnider/ Siemens /L&T make (97.12) CONTROL MCB Schnider/ Havells/Standard/Siemens/ Legrand make (97.13) PUSH BT. Schnider/Siemens/L&T make (97.14) TERMINALS Phonix make (97.15) RCCB of Legrand/Siemens/Havells / L&T/ Standard make (97.16) Hour run meter of CE/Kaycee make

2

-

-

... More
Providing Double flanged Leader / Pelican /Kirloskar make Cast iron Sluice Valve in delivery side conf. to Class IS 780 PN 1.0; one size higher than delivery outlet size of pump

2

-

-

... More
Providing Double flanged Leader / Pelican /Kirloskar make Cast iron Swing check type Reflux Valve in delivery side conf. to Class IS 780 PN 1.0; one size higher than delivery outlet size of pump

2

-

-

... More
Prov. and laying PVC Insulated armoured copper conductor cable Havells/Gloster/Khaitan make of suitable size and suitable for motor offered under item No I complete with flexible pipe and couplers from HPSEB meter to Panel, switch, starter complete job, The type and size shall be subject to approval of Electrical authorities and in case of its non acceptance the same shall be replaced free of cost by the tenderer

-

-

-

... More
Supply side : …………..mm^2

1

-

-

... More
Prov. and laying PVC Insulated round copper conductor cable of suitable size suitable for motor offered under item No 50 complete having suitable cores to fulfill requirement of star delta starter and protection/ controls from panel to motor 10 mtr cable per set shall be supplied free of cost ( cost inclusive in cost of pumpset) additional length shall be measured and to paid separately . Cost be quated for additional length over and above free cable of 10 Mtr/pumpset.

-

-

-

... More
Motor side : …………………. mm^2

70

-

-

... More
Providing Double flanged Leader / Pelican /Kirloskar make Cast iron Swing check type Reflux Valve in delivery side conf. to Class IS 5312 PN 1.0; equal to dia of rising main i.e. 125mm dia

1

-

-

... More
Providing 100 mm dial pressure guage of Fiebig/Bourden make having range 0-7 Kg/cm^2 with copper tubing, stop cock and allied access.as per IS 3624 - 1987 latest with up to date amendments

2

-

-

... More
Providing and fixing GMS/ MSERW pipe of suitable size as detailed here under for delivery and common header complete in all respects with all specials like bends, tees, reducers, increasers, companion flanges including rubber/ asbestos gaskets of minimum 3 mm thickness as per IS 1364-1983. The pipes shall be as per relevant IS Code, the flanges shall be of compatible with Pumps, valves etc and suitable for withstanding 1.5 times the working pressure likely to be induced as stipulated against item No I above

-

-

-

... More
Delivery side 125 mm Dia. (GMS) MC)

10

-

-

... More
L&T/Havells make shunt capacitor of suitable rating conf. to IS 2834-1986 latest with up to date amendments to raise power factor at site from 0.85 to 0.95, complete with required cable for direct connection to control panel and fittings.

2

-

-

... More
Supply of cable for water level guard

1

-

-

... More
Supply of supporting clamps

1

-

-

... More
Supply of cable clips of required size

1

-

-

... More
Erection of all equipments from Sr No 1 to 12 including cost of tee's bends, tappers and any other required fitting as per site condition and directions of engineer In charge.

1

-

-

... More
Schedule-A3 MAIN STAGE LIS DALLANG :- Supply , eraction, testing & commissioning of horizontal spindle , horozontal split casing , radial split Single /Multistagee centrifugal pumps or combination of pumps , in series/ parallel of recommonded make such as Mather and Platt/ KSb/ Becon weir/Kirlosker/BE /Jyoti or any other make approved from JSV Department as per BIS 1520-1980 with up to date ammendments read with BIS 9137- 1978 or latest edition to suitable fro lifting clear warer for uns=der mentioned characteristics with bronze impelles/ priming funnels casing ring and shaft sleaves or bronze shaft of steel grade with cast iron casing coupled directly through a flexible coupling on a common C.I/ Cast Iron base plate ( Base plate to be from the manufecturer of the pumping machinery unit only) to slip ring/ squirrel cage screen protected drip proof induction motor existing of standard make such as Kirlosker/Cromption/Bhel?NGEF?GEC/Siemen/Jyoti/ABB or any other make approved from JSV Department suitable for operation on 410 (+)/(-) 10% volts, 50 cycles/second , 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in operation range of (+) 10 % and (-) 15 % of the duty point head. The motor /motors confirming to minimum IE2 norms IS-12615/2011 with up to date ammendments . It Should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:- Discharge (Q) 7.34 LPS for each pump Total Dynamic head:- 206.30 meter a) LWL in sump well (h) 2938 meter b) Shaft level 2935 meter c) Level at discharge point 3120 meter d) Suction lift -ve 3 meter e) Discharge head 206.300 meter f) Static head 185 meter Rising main a) Length 1050 meter b) Dia 125mm Pumping hours 20 hours Altitude of installation above MS 2935 mtr. Characterstics of water Clear water with turbidity up to 50PPM. a) Temperature 10 digree centigrade.

2

-

-

... More
Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL.

1

-

-

... More
Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities

1

-

-

... More
a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments

1

-

-

... More
b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.

1

-

-

... More
c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)

1

-

-

... More
d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments

1

-

-

... More
e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments

1

-

-

... More
f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments

1

-

-

... More
g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments

1

-

-

... More
h) ICTP change over switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments

2

-

-

... More
i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments

2

-

-

... More
j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments

2

-

-

... More
k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments

2

-

-

... More
l) Providing suitable oil immersed star delta starter/direct on line starter/auto transformer starter/stater rotor starter / Soft Starter of MEI/.Kilburn/Jyoti /L&T/Siemens/ABB make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments

2

-

-

... More
m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)

2

-

-

... More
n) Providing antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971.

2

-

-

... More
Providing double flanged CI sluice valve PN1 of Leader/BHEL/Kirlosker/GLEd/Kilburn Fourses / Kartar make and equal to dia of suction pipe and cpable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments

2

-

-

... More
Providng double flanged cast steel sluice valves ASA-150 of leader/BHEL Kirlosker/Kilburn GLED/fourses make and one step higher then delivery line of pump and capable of withstanding the normal seat pressure and as per BIS standards with upto date ammdnements

2

-

-

... More
Providing double flanged swing type cast steel valve, ASA-150 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)

2

-

-

... More
Providing double flanged cast steel reflux valves class ASA-150 of Leader/BHEL/KILROSKER/Kartar/KILBURN/GLED/FOURSES make and of 125 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments.

1

-

-

... More
Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.

1

-

-

... More
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments

1

-

-

... More
Installation of all the items apparing at serial No.110 to 118 as per the systematic drawing

1

-

-

... More
Providing and fixing double flanged GMS/MSERW piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:

-

-

-

... More
Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe

12

-

-

... More
Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe

12

-

-

... More
Common header : One dia higher then delivery of pump x 125 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed

6

-

-

... More
Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor

-

-

-

... More
(a) Motor side (From switch to starter and starter to motor)

35

-

-

... More
(b) Supply side (From Meter of HPSEB to bus bar and switch)

90

-

-

... More
Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect.(For both phases).

1

-

-

... More
Schedule-A4 MAIN STAGE LIS THORANG :- Supply , eraction, testing & commissioning of horizontal spindle , horozontal split casing , radial split Single /Multistagee centrifugal pumps or combination of pumps , in series/ parallel of recommonded make such as Mather and Platt/ KSb/ Becon weir/Kirlosker/BE /Jyoti or any other make approved from JSV Department as per BIS 1520-1980 with up to date ammendments read with BIS 9137- 1978 or latest edition to suitable fro lifting clear warer for uns=der mentioned characteristics with bronze impelles/ priming funnels casing ring and shaft sleaves or bronze shaft of steel grade with cast iron casing coupled directly through a flexible coupling on a common C.I/ Cast Iron base plate ( Base plate to be from the manufecturer of the pumping machinery unit only) to slip ring/ squirrel cage screen protected drip proof induction motor existing of standard make such as Kirlosker/Cromption/Bhel?NGEF?GEC/Siemen/Jyoti/ABB or any other make approved from JSV Department suitable for operation on 410 (+)/(-) 10% volts, 50 cycles/second , 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in operation range of (+) 10 % and (-) 15 % of the duty point head. The motor /motors confirming to minimum IE2 norms IS-12615/2011 with up to date ammendments . It Should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:- Discharge (Q) 7.14 LPS for each pump Total Dynamic head:- 331.39 meter a) LWL in sump well (h) 2938 meter b) Shaft level 2935 meter c) Level at discharge point 3230 meter d) Suction lift -ve 3 meter e) Discharge head 331.390 meter f) Static head 295 meter Rising main a) Length 1800 meter b) Dia 125mm Pumping hours 20 hours Altitude of installation above MS 2935 mtr. Characterstics of water Clear water with turbidity up to 50PPM. a) Temperature 10 digree centigrade.

2

-

-

... More
Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL.

1

-

-

... More
Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities

1

-

-

... More
a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments

1

-

-

... More
b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.

1

-

-

... More
c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)

1

-

-

... More
d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments

1

-

-

... More
e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments

1

-

-

... More
f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments

1

-

-

... More
g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments

1

-

-

... More
h) ICTP change over switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments

2

-

-

... More
i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments

2

-

-

... More
j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments

2

-

-

... More
k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments

2

-

-

... More
l) Providing suitable oil immersed star delta starter/direct on line starter/auto transformer starter/stater rotor starter / Soft Starter of MEI/.Kilburn/Jyoti /L&T/Siemens/ABB make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments

2

-

-

... More
m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)

2

-

-

... More
n) Providing antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971.

2

-

-

... More
Providing double flanged CI sluice valve PN1 of Leader/BHEL/Kirlosker/GLEd/Kilburn Fourses / Kartar make and equal to dia of suction pipe and cpable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments

2

-

-

... More
Providng double flanged cast steel sluice valves ASA-300 of leader/BHEL Kirlosker/Kilburn GLED/fourses make and one step higher then delivery line of pump and capable of withstanding the normal seat pressure and as per BIS standards with upto date ammdnements

2

-

-

... More
Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)

2

-

-

... More
Providing double flanged cast steel reflux valves class ASA-300 of Leader/BHEL/KILROSKER/Kartar/KILBURN/GLED/FOURSES make and of 125 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments.

1

-

-

... More
Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.

1

-

-

... More
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments

1

-

-

... More
Installation of all the items apparing at serial No.123 to 131 as per the systematic drawing

1

-

-

... More
Providing and fixing double flanged GMS/MSERW piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:

-

-

-

... More
Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe

12

-

-

... More
Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe

12

-

-

... More
Common header : One dia higher then delivery of pump x 125 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed

6

-

-

... More
Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor

-

-

-

... More
(a) Motor side (From switch to starter and starter to motor)

35

-

-

... More
(b) Supply side (From Meter of HPSEB to bus bar and switch)

90

-

-

... More
Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all rerspect . ( For both phase).

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.