Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender
Machinery and Tools
Eprocure
Opening Date29 Jan 2021
Closing Date5 Feb 2021
Tender AmountRefer Documents
Costs
EMD
₹ 35,740Document Cost
₹ 400Tender Fee
Refer Documents
Summary
Providing Functional House Hold Tap (fhtc) Connection In Golwan Batrahan Sakri, Chatter Bassa Etc. Through Lwss Golwan Batarhan Hatpang Bassa In Tehsil Fatehpur District Kangra Hp Under Jal Jeevan Mission
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_HPIPH_43844_1Bid Award Id
ViewTender No
EE-JSD-FTR-EA-I/20-13863-90Tender Authority
Himachal Pradesh Irrigation And Public Health Department ViewPurchaser Address
-Website
http://http://hpiph.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Type of current :-A.C.Three phase supply with frequency 50 cycles per second.
-
-
-
Rated Voltage :-415 Vvolts (+/-) 10%
-
-
-
Characterstics of water :-(a).Temperature = 20oC (f) PH =_____
-
-
-
(b).Turbidity =Upto 10NTU (g) Total solids____Mg/Litre
-
-
-
©. Hardness =__Mg/Litre(as CaCo3) (h). Others_____
-
-
-
(d).Alkalinity =__Mg/Litre(as CaCo3)
-
-
-
Depth of Well Assembly :- Metres.
-
-
-
L.W.L.in Tube-Well :- Metres
-
-
-
Maximum draw down :- Metres
-
-
-
Centre line level of Pump :-464.10 Metres
-
-
-
Discharge level of highest point:- 547.00 Metres
-
-
-
Nos.of Pumps required :-2 No.Pump.
-
-
-
Capacity :- 11.87L.P.S.
-
-
-
Total head in Metres :-87.87 Metres
-
-
-
Length of Rising Main :- 20 Metres
-
-
-
Dia of Rising Main :- 150 mm dia GI (MEDIUM CLASS)
-
-
-
No.of working hours per day :16.00 Hours.
-
-
-
Limits of pump operation :- ( - ) 15% ( + ) 10% of total head.
-
-
-
H.P.of Motor/Drive unit :-Required H.P.of Pump at ( + ) 10% and ( - ) 15% of total head.
-
-
-
BHP.with following margins/multiplying factor at duty point,whichever is higher.
-
-
-
a).Upto 2 H.P. =1.5 (d) 10 to 20 H.P. =1.2
-
-
-
b).2 to 5 H.P. =1.4 (e) 20 to 100 H.P. =1.15
-
-
-
c) 5 to 10 H.P. =1.3 (f) Above 100 H.P. =1.10
-
-
-
Test Run :-16 Hours continueously for 7 days.
-
-
-
Providing and fixing automatic pannel borad including auto start, auto stop and restart facility single phase preventer , 3 phase indicator ,timer ,relay, selector switch, auto and manually start stop facilty, prevention of of phase reversal imbalance and overload and fixed with compatible starter in sheet enclosure with cabling complete in all respect to deliver results.
1
-
-
Providing C.I.double flanged sluice valve of Kirloskar/Kilburn/IVC.\/Fouress/Gled/BHEL/Leader make of size dia as per offered pump and Class PN 1.0 having one size higher to delivery size of Pump and capable of withstanding nominal seat pressure of 10.20Kgs/Cm2. conforming to IS 780-1984 (P-I)
1
-
-
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make C.I. double flanged swing Check type Reflux Valve having bye pass arrangement and one size higher to delivery size of pump(size 100 mm.dia and clasas PN 1.0 and shall be suitable for withstanding nominal seat pressure of 10.20 Kgs.cm2)conforming to IS: 5312-1984
1
-
-
Supply of Kirloskar/Kilburn/IVC/Foluress/Gled/BHEL/Leader make C.I. double flanged Swing Check Type Reflux Valve having bye pass arrangement and of size equal to dia of Rising Main i.e. 150 mm.& class PN 1.0 shall be suitable for withstanding nominal seat pressure of 10.20Kgs./Cm2).
1
-
-
Providing and laying suitable size copper PVC.insulated armoured power 3.5 core cable conforming to BIS-1554-Part-I -1988 or latest with uptodate ammendments Siemen/Gloster/ICC make from Meter of HPSEB. to MCB/OCB & from OCB to Busbar Switch & Starter(One cable carrying all three phases) including all other elecrc equipments/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc.laid in pipers or trenches size and make will be subject to approval of HPSEB.authorities. In case of non-acceptance by HPSEB auithority shall have to be replaced by the tenderer free of cost. (Note;- Size of cable specified by the tenderer)
10
-
-
Providing and laying PVC.jointless flat water proof cable 10 mm square as per BIS-694-1990(Latest with uptodate ammendments) suitable for the pump set offered from OCB to Motor, Motor to Starter including all other electric equipment such as;thimbles,flexible pipe,solder,nuts & bolts,cable glands etc.laid in pipes or trenches under floor. The type & make will be subject to approval of HPSEB.authorities. In case of non-acceptance byHPSEB.authoirity,it shall have to be replaced by the tenderer free of cost.(Note;- Size of cable specified by the tenderer)
130
-
-
Providing and laying doub le loop earthing with copper plate 600x600x3mm.thick electrode complete with material such as;char coal,common salt,G.I.Pipes,thimbles,nuts & bolts,digging of pits,G.I.wiring and 25x5mm.copper stripsw of required capacity conforming to BIS-3043-1987 latest with uptodate ammendments for above motors and other electrical equipments.
1
-
-
Supply of standard make circular dial pressure gauge of suitable range of Fiebeg/Bourden/Precision make with all accessories such as;stop cock,copper tubing etc.conforming to BIS-3624-1987 latest with uptodate ammendments
1
-
-
Lowering of Column Assembly of 100 mm.dia and common header 100 mm.dia G.I.Pipe Confirmng to IS-1239 or MSERW pipe 4.80 mm.thick conforming BIS-1978-82 considering site requirement duly flanged at every 3 Metre length with flanges conforming to BIS-6392-1971(Table-17) including tapers,flanges,rubber gaskets 3mm.thick as as per BIS-2712-1978,nuts & bolts as per 1364-1983 and specials upto collection tank as per directions of Engineer-in-Charge /as per layout approved by the Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total pressure indicated in item No.1(xii).
NOTE:- Actual laying tobe done as per final drawings to be approved by the Engineer-in-Charge.
65
-
-
Erection of all equipments from S.No. 1 to 3 and 5 to 6 including cost of tees, bends,tapers and any other fittings required as per conditions and as per directions of the Engineer-in-Charge.
1
-
-
Providing horizontal spindle, horizontal/redial split casing/and suction (backfull out arrangement) single/ double/ multistage centrifugal pump or combination of pumps, in series/parallel of recommended make such as Mather and Platt/KSB /Beaconweir/Kirloskar /BE/Jyoti as per BIS-1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterstics with bronze, impellers/priming funnels, casing ring and shaft sleaves of bronze, shaft of steel grade with cast iron casing coupled directly through a flexible coupling on a common CI/cast steel base plate(base plate to be from the manufacturer of the pumping set) to slipring/squirrel cage screen protected drip proof induction motor of Kirloskar/ BHEL/Crompton /NGEF/GEC/ Siwemen/ Jyoti/BHEL/ GEC/ABB/Sabar confirming to BIS-325-1978 read wih BIS:900-1978 (latest with upto date ammendments) It should be include the cost of bearing, nuts & bolts painting etc and shall be suitable for operation as per data given below :-
2
-
-
The pumping machinery shall be installed on properdised baseplate , which is to befrom the principal manufacturer of pumping set. The foundation of the machinery should be designedandanchored properly.
-
-
-
Location of site :-The site is located at a distance of 25 Kms.from Nurpur Road Railway Station.
-
-
-
The altitude of place in which :-Altitude of place is 460 Metres above Mean Sea Level. The motor is intended to work:-
-
-
-
Type of current :-A.C.Three phase supply with frequency 50 cycles per second.
-
-
-
Rated Voltage :-415 Vvolts (+/-) 10%
-
-
-
Characterstics of water :-(a).Temperature = 20oC (f) PH =_____
-
-
-
(b).Turbidity =Upto 10NTU (g) Total solids____Mg/Litre
-
-
-
©. Hardness =__Mg/Litre(as CaCo3) (h). Others_____
-
-
-
(d).Alkalinity =__Mg/Litre(as CaCo3)
-
-
-
Depth of Well Assembly : Metres.
-
-
-
L.W.L.in Collection Tank :- Metres
-
-
-
Maximum draw down :- Metres
-
-
-
Centre line level of Pump :- 543 Metres
-
-
-
Discharge level of highest point:-589 Metres
-
-
-
Nos.of Pumps required :-2 No.Pump.
-
-
-
Capacity :- 9.89 L.P.S.
-
-
-
Total head in Metres :- 58.30 Metres
-
-
-
Length of Rising Main :- 1920 Metres ( 1300 mtrs.existing and 620 mtrs.proposed.)
-
-
-
Dia of Rising Main :-125mm.dia G.I..pIpe,
-
-
-
No.of working hours per day :-16.00 Hours.
-
-
-
Limits of pump operation :- ( - ) 15% ( + ) 10% of total head.
-
-
-
H.P.of Motor/Drive unit :-Required H.P.of Pump at ( + ) 10% and ( - ) 15% of total head.
-
-
-
BHP.with following margins/multiplying factor at duty point,whichever is higher.
-
-
-
a).Upto 2 H.P. =1.5 (d) 10 to 20 H.P. =1.2
-
-
-
b).2 to 5 H.P. =1.4 (e) 20 to 100 H.P. =1.15
-
-
-
c) 5 to 10 H.P. =1.3 (f) Above 100 H.P. =1.10
-
-
-
Test Run :-16 Hours continueously for 7 days.
-
-
-
Providing and fixing automatic pannel borad including auto start, auto stop and restart facility single phasepreventer , 3 phase indicator ,timer ,relay, selector switch, auto and manually start stop facilty, prevention of of phase reversal imbalance and overload and fixed with compatible starter in sheet enclosure with cabling complete in all respect to deliver results.
2
-
-
Providing C.I.double flanged sluice valve of Kirloskar/Kilburn/IVC.\/Fouress/Gled/BHEL/Leader make of size dia as per offered pump and Class PN 1.0 having one size higher to delivery size of Pump and capable of withstanding nominal seat pressure of 10.20Kgs/Cm2. conforming to IS 780-1984 (P-I)
2
-
-
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make C.I. double flanged swing Check type Reflux Valve having bye pass arrangement and one size higher to delivery size of pump(size 125 mm.dia and clasas PN 1.0 and shall be suitable for withstanding nominal seat pressure of 10.20 Kgs.cm2)conforming to IS: 5312-1984
2
-
-
Supply of Kirloskar/Kilburn/IVC/Foluress/Gled/BHEL/Leader make C.I. double flanged Swing Check Type Reflux Valve having bye pass arrangement and of size equal to dia of Rising Main i.e. 125 mm.& class PN 1.0 shall be suitable for withstanding nominal seat pressure of 10.20Kgs./Cm2).
1
-
-
Providing and laying suitable size copper PVC.insulated armoured power 3.5 core cable conforming to BIS-1554-Part-I -1988 or latest with uptodate ammendments Siemen/Gloster/ICC make from Meter of HPSEB. to MCB/OCB & from OCB to Busbar Switch & Starter(One cable carrying all three phases) including all other elecrc equipments/ accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc.laid in pipers or trenches size and make will be subject to approval of HPSEB.authorities. In case of non-acceptance by HPSEB.auithority shall have to be replaced by the tenderer free of cost. (Note;- Size of cable specified by the tenderer)
10
-
-
Providing and laying PVC.jointless flat water proof cable as per BIS-694-1990(Latest with uptodate ammendments) suitable for the pump set offered from OCB to Motor, Motor to Starter including all other electric equipment such as;thimbles,flexible pipe,solder,nuts & bolts,cable glands etc.laid in pipes or trenches under floor. The type & make will be subject to approval of HPSEB.authorities. In case of non-acceptance by HPSEB.authoirity,it shall have to be replaced by the tenderer free of cost. (Note;- Size of cable specified by the tenderer)
30
-
-
Providing and laying doub le loop earthing with copper plate 600x600x3mm.thick electrode complete with material such as;char coal,common salt,G.I.Pipes,thimbles,nuts & bolts,digging of pits,G.I.wiring and 25x5mm.copper stripsw of required capacity conforming to BIS-3043-1987 latest with uptodate ammendments for above motors and other electrical equipments.
1
-
-
Supply of standard make circular dial pressure gauge of suitable range of Fiebeg/Bourden/Precision make with all accessories such as;stop cock,copper tubing etc.conforming to BIS-3624-1987 latest with uptodate ammendments.
1
-
-
Laying ,jointing if Delivery /sunction pipe of -- mm.dia and common header ---- mm.dia G.I.Pipe 4mm.thick conforming BIS-1978-82 considering site requirement duly flanged at every 3 Metre length with flanges conforming to BIS-6392-1971(Table-5) including tapers,flanges,rubber gaskets 3mm.thick as as per BIS-2712-1978,nuts & bolts as per 1364-1983 and specials upto collection tank as per directions of Engineer-in-Charge /as per layout approved by the Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total pressure indicated in item No.1(xii).
-
-
-
Suction pipe --mm dia GI medium duly flanged T-17 ( Dia of GI Pipe specified by the tenderer)
12
-
-
Delivery pipe ---mm dia duly flanged T-17( Dia of GI Pipe specified by the tenderer)
5
-
-
Common header 100 mm dia GI medium thick T-17
5
-
-
Erection of all equipments from S.No. 8 to 10 and 11 to 13 including cost of tees, bends,tapers and any other fittings required as per conditions and as per directions of the Engineer-in-Charge.
1
-
-
Providing horizontal spindle, horizontal/redial split casing/and suction (backfull out arrangement) single/ double/ multistage centrifugal pump or combination of pumps, in series/parallel of recommended make such as Mather and Platt/KSB /Beaconweir/Kirloskar /BE/Jyoti as per BIS-1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterstics with bronze, impellers/priming funnels, casing ring and shaft sleaves of bronze, shaft of steel grade with cast iron casing coupled directly through a flexible coupling on a common CI/cast steel base plate(base plate to be from the manufacturer of the pumping set) to slipring/squirrel cage screen protected drip proof induction motor of Kirloskar/ BHEL/Crompton /NGEF/GEC/ Siwemen/ Jyoti/BHEL/ GEC/ABB/Sabar confirming to BIS-325-1978 read wih BIS:900-1978 (latest with upto date ammendments) It should be include the cost of bearing, nuts & bolts painting etc and shall be suitable for operation as per data given below :-
2
-
-
The pumping machinery shall be installed on properdised baseplate , which is to befrom the principal manufacturer of pumping set. The foundation of the machinery should be designedandanchored properly.
-
-
-
Location of site :-The site is located at a distance of 25 Kms.from Nurpur Road Railway Station.
-
-
-
The altitude of place in which :-Altitude of place is 460 Metres above Mean Sea Level. The motor is intended to work:-
-
-
-
Type of current :-A.C.Three phase supply with frequency 50 cycles per second.
-
-
-
Rated Voltage :-415 Vvolts (+/-) 10%
-
-
-
Characterstics of water :-(a).Temperature = 20oC (f) PH =_____
-
-
-
(b).Turbidity =Upto 10NTU (g) Total solids____Mg/Litre
-
-
-
©. Hardness =__Mg/Litre(as CaCo3) (h). Others_____
-
-
-
(d).Alkalinity =__Mg/Litre(as CaCo3)
-
-
-
Depth of Well Assembly :130 Metres.
-
-
-
L.W.L.in Collection Tank :- Metres
-
-
-
Maximum draw down :- Metres
-
-
-
Centre line level of Pump :- 543 Metres
-
-
-
Discharge level of highest point:-578 Metres
-
-
-
Nos.of Pumps required :-2 No.Pump.
-
-
-
Capacity :- 1.98 L.P.S.
-
-
-
Total head in Metres :- 49.75 Metres
-
-
-
Length of Rising Main :- 2280 Metres
-
-
-
Dia of Rising Main :-80 mm.dia G.I..pIpe,
-
-
-
No.of working hours per day :-16.00 Hours.
-
-
-
Limits of pump operation :- ( - ) 15% ( + ) 10% of total head.
-
-
-
H.P.of Motor/Drive unit :-Required H.P.of Pump at ( + ) 10% and ( - ) 15% of total head.
-
-
-
BHP.with following margins/multiplying factor at duty point,whichever is higher.
-
-
-
a).Upto 2 H.P. =1.5 (d) 10 to 20 H.P. =1.2
-
-
-
b).2 to 5 H.P. =1.4 (e) 20 to 100 H.P. =1.15
-
-
-
c) 5 to 10 H.P. =1.3 (f) Above 100 H.P. =1.10
-
-
-
Test Run :-16 Hours continueously for 7 days.
-
-
-
Providing and fixing automatic pannel borad including auto start, auto stop and restart facility single phasepreventer , 3 phase indicator ,timer ,relay, selector switch, auto and manually start stop facilty, prevention of of phase reversal imbalance and overload and fixed with compatible starter in sheet enclosure with cabling complete in all respect to deliver results.
2
-
-
Providing C.I.double flanged sluice valve of Kirloskar/Kilburn/IVC.\/Fouress/Gled/BHEL/Leader make of size dia as per offered pump and Class PN 1.0 having one size higher to delivery size of Pump and capable of withstanding nominal seat pressure of 10.20Kgs/Cm2. conforming to IS 780-1984 (P-I)
2
-
-
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make C.I. double flanged swing Check type Reflux Valve having bye pass arrangement and one size higher to delivery size of pump(size 80 mm.dia and clasas PN 1.0 and shall be suitable for withstanding nominal seat pressure of 10.20 Kgs.cm2)conforming to IS: 5312-1984
2
-
-
Supply of Kirloskar/Kilburn/IVC/Foluress/Gled/BHEL/Leader make C.I. double flanged Swing Check Type Reflux Valve having bye pass arrangement and of size equal to dia of Rising Main i.e. 80 mm.& class PN 1.0 shall be suitable for withstanding nominal seat pressure of 10.20Kgs./Cm2).
1
-
-
Providing and laying suitable size copper PVC.insulated armoured power 3.5 core cable conforming to BIS-1554-Part-I -1988 or latest with uptodate ammendments Siemen/Gloster/ICC make from Meter of HPSEB. to MCB/OCB & from OCB to Busbar Switch & Starter(One cable carrying all three phases) including all other elecrc equipments/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc.laid in pipers or trenches size and make will be subject to approval of HPSEB.authorities. In case ofn on-acceptance byn HPSEB.auithority shall have to be replaced by the tenderer free of cost.(Note;- Size of cable specified by the tenderer)
10
-
-
Providing and laying PVC.jointless flat water proof cable as per BIS-694-1990(Latest with uptodate ammendments) suitable for the pump set offered from OCB to Motor, Motor to Starter including all other electric equipment such as;thimbles,flexible pipe,solder,nuts & bolts,cable glands etc.laid in pipes or trenches under floor. The type & make will be subject to approval of HPSEB.authorities. In case of non-acceptance by HPSEB.authoirity,it shall have to be replaced by the tenderer free of cost. .(Note;- Size of cable specified by the tenderer)
15
-
-
Providing and laying doub le loop earthing with copper plate 600x600x3mm.thick electrode complete with material such as;char coal,common salt,G.I.Pipes,thimbles,nuts & bolts,digging of pits,G.I.wiring and 25x5mm.copper stripsw of required capacity conforming to BIS-3043-1987 latest with uptodate ammendments for above motors and other electrical equipments.
1
-
-
Supply of standard make circular dial pressure gauge of suitable range of Fiebeg/Bourden/Precision make with all accessories such as;stop cock,copper tubing etc.conforming to BIS-3624-1987 latest with uptodate ammendments.
1
-
-
Laying ,jointing if Delivery /sunction pipe of -- mm.dia and common header ---- mm.dia G.I.Pipe 4mm.thick conforming BIS-1978-82 considering site requirement duly flanged at every 3 Metre length with flanges conforming to BIS-6392-1971(Table-5) including tapers,flanges,rubber gaskets 3mm.thick as as per BIS-2712-1978,nuts & bolts as per 1364-1983 and specials upto collection tank as per directions of Engineer-in-Charge /as per layout approved by the Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total pressure indicated in item No.1(xii).
-
-
-
Suction pipe --mm dia GI medium duly flanged T-17 ( Dia of GI Pipe specified by the tenderer)
12
-
-
Delivery pipe ---mm dia duly flanged T-17( Dia of GI Pipe specified by the tenderer)
5
-
-
Common header 80 mm dia GI medium thick T-17
5
-
-
Erection of all equipments from S.No. 15 to 16 and 17 to 20 including cost of tees, bends,tapers and any other fittings required as per conditions and as per directions of the Engineer-in-Charge.
1
-
-
Excavation in foundation treanches(Pipe & Pits) up to all depths in all classification of earth work such as pick work,jumper work,saturated soil including bailing or pumping out water,blasting soft /hard rock where blasting is prohibited in all lifts including trimming & dressing of sides leveling of beds to correct grade i/c shoring/strutting planking,timbering & dewatering wherever required stacking the usable & unusable material/soil separately & after laying,jointing & testing of pipes,returning the useable soil in trenches in 15cm layers including consolidating of such deposited layer by raming & watering & then disposing of all surplus excavated soil/unusable material as directed with in all leads & lifts including restoration of unmetalled surface to its original condition & including cost of diversion for traffic,night signals,fixing caution boards,crossing over trenches for access to houses,fencing etc.completein all respects with in all leads & lifts as per directions of Engineer-in-Charge.
860.76
-
-
Laying and jointing in trenches to be levelled to grade, BIS marked GI flanged pipes confirming to BIS:1239 (latest with upto date ammendments) of 125,100 & 80 mm dia (Medium class) duly flanged to be welded after 30 mtr. ,interval of pipe with intermediate butt welded joints including the cost of flanges, bends/short pieces made from parent tubes of diferent degrees cutting welding and jointing with flanges conforming to tables as specified below of BIS: 6392 (latest with upto date ammendments) welded at both ends as per BIS:816 (latest with upto date ammendments) with electrodes confirming to BIS 814 (latest with upto date ammendments) & provided with nuts and bolts BIS: 1369 (latest with upto date ammendments) of required sizes 4 mm thick champion make compressed asbestos fiber gasket or synthetic rubber gasket confirming to BIS:2712 (latest with upto date ammendments) & approved specifications as per site conditions including flushing, cleaning & hydraulic testing complete to the best satisfaction of Engineer-in-charge.
-
-
-
Stage -I
RD- 00 to RD-20 150 mm Table-17
20
-
-
Phase-I (Stage-II)
RD- 00 to RD-620 125 mm Table-5
620
-
-
Phase-II (Stage-II)
RD- 00 to RD-12280 80 mm Table-5
2280
-
-