Himachal Pradesh Irrigation And Public Health Department Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender

Works
Civil And Construction
Irrigation Work
Eprocure
Opening Date21 Nov 2023
Closing Date2 Dec 2023
Tender Amount₹ 3,04,13,897 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Voltage Protection device to protect panel from over voltage and under voltage for the above rating of machinery.

-

-

-

... More
Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage.

-

-

-

... More
Multi-function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make MAS/L&T.

-

-

-

... More
Main incomer MCCB/MCB of suitable for 2 sets of suitable rating motor of L&T/ABB make on the feeder for pumping set confirming to BIS 2516-1985 ( Latest edition).

-

-

-

... More
Individual Starter incomer MCCB/MCB suitable for 2 sets of motor of L&T/ABB make on the feeder for pumping set confirming to BIS 2516-1985 ( Latest edition).

-

-

-

... More
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with up to date amendments.

-

-

-

... More
LED On / Off & Trip indicator and push buttons, Control and power wiring,Powercapacitor,Cooling fan 230 VAC, Control terminal, Bus Bar, i.e. Bolt, insulator, etc.

-

-

-

... More
Surge suppressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges for above rating.

-

-

-

... More
Control Transformer to provide a stable control voltage to safeguard the control circuit of all the components from the voltage surges and spikes.

-

-

-

... More
Providing and fixing of Kirloskar/leader make double flanged C.I(Class PN-1.00)sluice valve having size one dia. Higher than pump size to delivery of pump and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS 780-1984.

-

-

-

... More
Providing and fixing of Kirloskar/leader make of size one dia hiegher the delivery of pump C.I (Class PN-1.00) double flanged ( swing check type) reflux valve having bye pass arrangement and capable of withstanding nominal seat pressure of 10.20 kg/cm2 as per BIS 5312-1984.

-

-

-

... More
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments siemen/closter/ICC make form meter of HPSEB- to MCB and form MCB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer.

-

-

-

... More
Providing and fixing of Leader /Kirloskar make 300 mm dia CIClass PN 1.00 double flanged (swing check type) reflux valve having bye pass arrangement for withstanding nominal seat pressure of 10.20 Kg/Cm 2 as per BIS 5312-1984

-

-

-

... More
Providing and fixing of PVC joint less flat water proof cable as per BIS: 694-1990 latest with upto date amendments suitable for the pump sets offered from MCB to motor including all other electrical equipment/accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced by tender.

-

-

-

... More
Providing and laying double loop earthing with copper plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and copper strips of required capacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and other electrical equipment’s.

-

-

-

... More
Providing and fixing of standard make circular dial pressure gauge 0.10 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to BIS: 3624-1987 latest with upto date amendments.

-

-

-

... More
Providing and laying delivery pipe 250 mm dia. and common header 300 mm dia MSERW pipe jointed with MS flanges of table-5 as per IS: 3589-2001 (upto a length of 20 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses as per layout drawings approved by Engineer-in-Charge.

-

-

-

... More
Providing and fixing of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments Baja/L&T/Asian/cromption make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to BIS –4064-1978 or latest with HRC fuses (range to be specified by the tendrerer).

-

-

-

... More
CENTRIFUGAL (1st phase) Providing installation of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) single/double/ multistage centrifugal pump or combination of pump in series of recommended make such as Mather and Platt/KSB/Kirloskar as per relevant code with up to date amendments, read with or latest edition suitable for lifting Raw water for under mentioned characteristics with suitable alloy impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a MS/Cast steel base plate ( base plate to be procurred from the manufacturers of the pumping unit only) to squirrel cage drip proof induction motor of standard make such as Kirloskar/Crompton/NGEF and suitable for operation on 400 (+)/-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be at least 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 15% of the duty point head. The motor should be as per IS: 325-1978 with up to date amendments Please refere SOQ uploaded in PDF format for specification, quantity and unit of below items:-

360

-

-

... More
Supply, Installation, Testing and Commissioning of premium Star Delta Starter panel for Centrifugal pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 3 Nos. pumps each of the rating through Star Delta Starter mechanism. Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators.

-

-

-

... More
Star, Delta and Mains Power Contactors of required ratings as per type-2 co-ordination for suitable rating starter

-

-

-

... More
Voltage Protection device to protect panel from over voltage and under voltage for the above rating of machinery.

-

-

-

... More
Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage.

-

-

-

... More
Multi-function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make MAS/L&T.

-

-

-

... More
Main incomer MCCB/MCB of suitable motor rating of L&T/ABB make on the feeder for pumping set confirming to BIS 2516-1985 ( Latest edition).

-

-

-

... More
Individual Starter incomer MCCB/MCB of suitable for motor of L&T/ABB make on the feeder for pumping set confirming to BIS 2516-1985 ( Latest edition).

-

-

-

... More
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with up to date amendments.

-

-

-

... More
LED On / Off & Trip indicator and push buttons, Control and power wiring,Powercapacitor,Cooling fan 230 VAC, Control terminal, Bus Bar, i.e. Bolt, insulator, etc.

-

-

-

... More
Surge suppressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges for above rating.

-

-

-

... More
Control Transformer to provide a stable control voltage to safeguard the control circuit of all the components from the voltage surges and spikes.

-

-

-

... More
Capacitor of L&T/Bajaj/Assian/Crompton make as per IS:2834-1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVAR rating according to HP offered including cables as per relevant ISI code ( of Siemens/Glocter/IEC make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064-1978 with upto date amendments 25 KVAR

-

-

-

... More
Providing Hour run meter of recommended make of suitable capacity as per IS: 722 (Latest edition)

-

-

-

... More
Providing and fixing.C.I sluice valve on suction side 200mm dia.

-

-

-

... More
Providing and fixing of double flanged Cast Steel sluice valve of Leader/Kirloskar/KSB make of one dia higher the delivery of pump for the delivery pipe and capable of class ASA-300 withstanding the 52kg/cm2 seat pressure as per BS: 1414/API600 with up to date amendments.

-

-

-

... More
Providing and fixing of double flanged Cast steel sluice valve of Leader/Kirloskar/ KSB make on delivery line and size one dia higher the delivery of pump capable of with standing the 52kg/cm2 seat pressure and as per IS –1414 API-600class-ASA-300) with up to date amendments.

-

-

-

... More
Providing and fixing of double flanged (Swing type) Cast steel reflux valve of Leader/Kirloskar/ KSB make 300mm Dia on rising main line of pump capable of with standing normal seat pressure as per BS –1868/ API-600(class, ASA-300 with up to date amendments

-

-

-

... More
Providing and fixing of 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0-52 Kg/cm2

-

-

-

... More
Providing and fixing double flanged G.M.S/ MSERW piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.

-

-

-

... More
The size of the various components to be as under:-

-

-

-

... More
Suction pipe: 200mm dia

-

-

-

... More
Delivery pipe: 250mm dia

-

-

-

... More
Common Header: 300mm dia

-

-

-

... More
And will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.

-

-

-

... More
Prov. & Fixing Havels/Fanalex/Gloster/National make three core Copper conductor cable sutable for AC supply up to 1100 Volt conforming to IS 694 or IS 1554

-

-

-

... More
Providing and fixing double loop earthing and copper plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx6mm copper & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.

-

-

-

... More
CENTRIFUGAL (2nd phase) Providing installation of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) single/double/ multistage centrifugal pump or combination of pump in series of recommended make such as Mather and Platt/KSB/Kirloskar as per relevant code with up to date amendments, read with or latest edition suitable for lifting Raw water for under mentioned characteristics with suitable alloy impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a MS/Cast steel base plate ( base plate to be procurred from the manufacturers of the pumping unit only) to squrrel cage drip proof induction motor of standard make such as Kirloskar/Crompton/NGEF and suitable for operation on 400 (+)/-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be at least 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 15% of the duty point head. The motor should be as per IS: 325-1978 with up to date amendments pump in complete operating range with mounting stand/ duck foot bend, steel guide wire with mounting hook, lowering chain and standarad accessories as supplied the manufacture complete and suitable for fullfilling the following requirements :- Please refere SOQ uploaded in PDF format for specification, quantity and unit of below items:-

80

-

-

... More
Supply, Installation, Testing and Commissioning of premium Star Delta Starter panel for Centrifugal pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 3 Nos. pumps each of the rating through Star Delta Starter mechanism. Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators.

-

-

-

... More
Star, Delta and Mains Power Contactors of required ratings as per type-2 co-ordination for starter

-

-

-

... More
Voltage Protection device to protect panel from over voltage and under voltage for the above rating of machinery.

-

-

-

... More
Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage.

-

-

-

... More
Multi-function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make MAS/L&T.

-

-

-

... More
Main incomer MCCB/MCB of suitable for motor of L&T/ABB make on the feeder for pumping set confirming to BIS 2516-1985 ( Latest edition).

-

-

-

... More
Individual Starter incomer MCCB/MCB of suitable for motor of L&T/ABB make on the feeder for pumping set confirming to BIS 2516-1985 ( Latest edition).

-

-

-

... More
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with up to date amendments.

-

-

-

... More
LED On / Off & Trip indicator and push buttons, Control and power wiring,Powercapacitor,Cooling fan 230 VAC, Control terminal, Bus Bar, i.e. Bolt, insulator, etc.

-

-

-

... More
Surge suppressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges for above rating.

-

-

-

... More
Control Transformer to provide a stable control voltage to safeguard the control circuit of all the components from the voltage surges and spikes.

-

-

-

... More
Capacitor of L&T/Bajaj/Assian/Crompton make as per IS:2834-1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of required 9.00KVAR rating according to HP offered including cables as per relevant ISI code ( of Siemens/Glocter/IEC make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064-1978 with upto date amendments

-

-

-

... More
Providing Hour run meter of recommended make of suitable capacity as per IS: 722 (Latest edition)

-

-

-

... More
Providing and fixing of double flanged Cast Iron sluice valve of Leader/Kirloskar make of 125 mm dia for the suction pipe and capable of withstanding the 10.20kg/cm2 seat pressure as per IS: 780 -1984 with up to date amendments. Class-PN-1

-

-

-

... More
Providing double flanged Cast steel sluice valve of Leader/Kirloskar make and size one dia higher the delivery of pump and capable of with standing the 52kg/cm2 seat pressure and as per BS 1414 API (class-ASA-300) with up to date amendments.

-

-

-

... More
Providing and fixing of double flanged (Swing type) Cast steel reflux valve of Leader/Kirloskar/KSB make of size one dia heigher the pump delivery having bye pass arrangement on the delivery line of pump and capable of with standing 52kg/cm2 seat pressure as per BS –1868/ API-600(class, ASA-300 with up to date amendments

-

-

-

... More
Providing and fixing of double flanged (Swing type) Cast steel reflux valve having bye pass arrangement on the delivery line of pump and capable of with standing 52kg.cm2 seat pressure as per BS –1868/ API-600(class, ASA-300 with up to date amendments

-

-

-

... More
Providing and fixing of 100 mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0-52 Kg/cm2

-

-

-

... More
Providing and fixing double flanged G.M.S/ MSERW piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.

-

-

-

... More
The size of the various components to be as under:-

-

-

-

... More
(i) Suction pipe 125mm dia Min. length = 15 mtr.

-

-

-

... More
(ii) Delivery pipe 125 mm dia -do- = 5 mtr.

-

-

-

... More
(iii) Common Header 150 mm dia -do- = 10 mtr.

-

-

-

... More
And will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.

-

-

-

... More
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/GICO/Grandly/National make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.

-

-

-

... More
Motor side: Suitable size cable of required length

-

-

-

... More
Supply side:Suitale size cable: of required length

-

-

-

... More
Providing and fixing double loop earthing and copper plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx3mm copper strips & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.

-

-

-

... More
RISING MAIN Excavation in foundation and trenches etc.(in pipes and pits) in all kinds of soils such as pick work, jumper work, blasting in soft / hard rock, chiselling/wedging out of rock/where blasting prohibited) saturated soil stacking the excavated earth within all leads and lifts clear from the edge of excavation and then returning the stacked soil in 15cm layers when required into plinth sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed by the Engineer –in-charge.

2292.78

-

-

... More
Providing, laying, jointing and testing in trenches of galvanized MSERW flanged pipes conforming to IS/ISO 3183-2007 Grade L210 or A as per dimensions weight and test pressure mentioned below in a random length of 4m - 6m, The M.S. flanges are to be provided 5% of total joints as per table below conforming to IS: 6392-1971 (latest upto date amendments) and welding of flanges with pipes as per IS: 816-1965 with a electrode as per IS: 814-1967 including required Nos. and size of M.S. nut and bolts as per IS: 1369-1967 and compressed asbestos fiber jointing gaskets sheet not less than 3mm thick sas per IS: 2712-1965 & 95% butt welded joints by considering minimum three layers. The welding of flanges to be done on both faces in two layers on outer face + one layer on inner face to make the joints leak proof and to the entire satisfaction of the Engineer-in-charge. The laying of pipes should be conformed to IS: 5822-1994 (earth work in trenches, MS flanges and butt welded joint to be measured and paid for seprately) . The pipe shall have zinc coating innside and out side as per IS:4736 in factory latest with upto date ammendements.

-

-

-

... More
MSERW pipe300 mm dia. with Wall thickness of 4.80 mm with O.D.323.90 mm having 37.77 kg/mtr.

910

-

-

... More
MSERW pipe300 mm dia. with Wall thickness of 5.20 mm with O.D.323.90 mm having 40.87 kg/mtr.

1350

-

-

... More
MSERW pipe300 mm dia. with Wall thickness of 5.60 mm with O.D.323.90 mm having 43.96 kg/mtr.

240

-

-

... More
Laying,jointing and testing intrenches GMS plain ended flanged pipes of 150 mm diametre Heavy class grade and flanged table confirming to IS:1239-2001 (latest up to date amendments) suitable to with stand required hydraulic test pressure in a random length of 4 to 6 meters and jointed with MS Flanges 5% and (remaining buttwelded joints) 5 % joints to be flanged including required Number & size of nuts and bolts as per IS 1364-2002 and compressed asbestos fibre jointing gasket sheet not less than 3mm thickness as per IS 2712-1978 . The welding of flanges to be done on both faces( inone layer in side and two layers out side) to make the joints leak proof after four Circumfprential butt welded joints, electrical, arc welding in requisite number of weld so as to achive the minimum effective throate thickness of weld conforming to IS as per IS 816-1957 by using welding electrodes as per IS 814-2004.The laying of pipe should conform to IS 5822-1994 and as per CPHEEO manual and will include all operations such as cutting, welding, jointing,flushing, cleaning,hydroulic testing,cost of flanges all kinds of flanged bends of diffrent degrees made from parrent pipe with three cut weld,cost of butt welding,dye penetration test and charges of materials up to all leads and lifts complete in all respect to the entire satisfaction of Engineer-in-charge. (Earth work in trenches but welded joints and flanged joints to be measured and paid for searately).

1490

-

-

... More
Providing and welding M.S. flanges at suitable point, with butt welded joint,conforming to following tables as per IS 6392-1971 (Latest with upto date amendments) with plain end MSERW pipe in requsite number of layers on both faces to make the joint leak proof . The welding of flanges should conform to IS:816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364. including cost of gasket sheet nuts & bolts. The thickness of gasket sheet not less then 3.00mm conforming to IS 2712-1998. The work shall be done to the entire satifaction of engineer in charge with in all leads and lifts.tion of Engineer-in-Charge. Booster & 1st Phase 300 mm dia

-

-

-

... More
MSERW Pipes as per IS/ISO:3183-2007 of Grade L 210 or A T-5

29

-

-

... More
MSERW Pipes as per IS/ISO:3183-2007 of Grade L 210 or A T-17

5

-

-

... More
MSERW Pipes as per IS/ISO:3183-2007 of Grade L 210 or A T-28

14

-

-

... More
GMS Tube 150 mm dia (M.C.) Flange T- 28

8

-

-

... More
GMS Tube 150 mm dia (M.C.) Flange T- 17

3

-

-

... More
GMS Tube 150 mm dia (M.C.) Flange T- 5

1

-

-

... More
Providing circumferencial Butt welded joints by electrical arc welding to GMS/MSERW pipe, welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS: 816-1969 specifications, by using welding electrodes of Advani/Orelin make conforming to IS:814-1991, at site of work complete in all respects, including manual / mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.

-

-

-

... More
300 mm dia. 1St Phase :-

-

-

-

... More
MSERW Pipes as per IS/ISO:3183-2007 of Grade L 210 or A (W.T.4.80,5.20,5.60 mm)

371

-

-

... More
150 mm dia. 2nd Phase :-

-

-

-

... More
GMS Tube 150 mm dia (H.C)

236

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.