Himachal Pradesh Irrigation And Public Health Department Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender

Works
Civil And Construction
Irrigation Work
Eprocure
Opening Date25 Oct 2024
Closing Date7 Nov 2024
Tender Amount₹ 74,19,440 
Notes
Download

Costs

Summary

Improvement Of 8 Nos Irrigation Scheme That Is Tubewell No 18 At Village Kad Tubewell No 68 And 71 Jeetpur Baheri Tubewell No 34 At Nakroh Tubewell No. 22 And25 At Kuneran Tubewell No. 30 At Gondpur Banehra And Tubewell No. 3 At Badoh In Tehsil Amb

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2nd.class brick work using common burnt clay building bricks in foundation and plinth in cement mortor 1:4 (1cement :4 sand) in all lead and lifts and as per the direction of the Engineer-in-Charge.

43.91

-

-

... More
1st. class brick work using common burnt clay building bricks in foundation and plinth in cement mortor 1:6 (1 cement : 6 sand) in all lead and lifts and as per the directions of the Engineer-in-Charge.

57.54

-

-

... More
Filling in plinth with sand under floors including watering ramming consolidating and dressing complete under flooring complete in all respect including carriage of materials in all leads and lifts

11

-

-

... More
P/L RCC seismic beam in cement concrete work 1:2:4(1cement:2sand: 4 water borne aggregate 20mm nominal size & curing complete excluding the cost of form work and reinforcement for reinforced concrete work in Foundations,footings bases of columns and the like and mass concrete complete in all respect including carriage of materials in all leads and lifts

2.04

-

-

... More
Providing and laying cement concrete work 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of from work and reinforcement for reinforced concrete work in Suspended floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever upto floor two level complete in all respect including carriage of materials in all leads and lifts

18.94

-

-

... More
1st. class brick work using common burnt clay building bricks in superstructure in cement mortor 1:6 (1 cement :6 sand) in all lead and lifts and as per the direction of the Engineer-in-Charge.

38.48

-

-

... More
Half brick work using common burnt clay building bricks in superstructure above 1st floor level in cement mortar 1:4( 1Cement, 4 Sand ) of 2nd class bricks complete in all respect with in all leads and lifts.

115.96

-

-

... More
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to giv a fair finish including centring. shuttering. strutting and propping etc with wooden battens and ballies. height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs.and removal of the same for insitu-reinforced concrete and plain concrete work in Flat surfaces such as soffits of suspended floors, roofs, landings and the like floor etc.upto 200mm in thickness including carriage of materials within all leads and lifts complete as per the direction of Engineer-in-charge.

-

-

-

... More
Vertical sufaces such as walls any thickness partitions and the like including attached pillasters buttresses, plinth and string courses and the like :-

30.72

-

-

... More
Flat surfaces such as soffits of suspended floor, roofs, landings and like floors etc. upto 200 mm in thickness

95.78

-

-

... More
Sides and soffits of beams,beam haunching, lintels etc. :-

5.66

-

-

... More
Providing tor steel reinforcement for RCC work including bending, binding and placing in positon complete including carriage of material in all leads & lifts complete as per the direction of Engineer-in-charge.

1704.6

-

-

... More
15mm cement plaster in single coat in fair side of brick/stone masonery for interior plastering upto floor two level including arrises,internal,founded angles,chamfers and/or rounded angles chamfers and/or rounded angles not exceeding in girth & finished even and smooth in cement mortar 1:6(1cement:6sand) complete in all respect including carriage of materials in all leads and lifts

193.04

-

-

... More
15 mm cement plaster in single coat on fair side of brick masonry for interior plastering upto floor two level including arrises, internal rounded angle, chamfers and /or rounded angles not exceeding 80 mm in girth and finished even and smooth with cement mortor 1:3 ( 1 cement :3 sand ) in all leads and lifts as per the direction of the Enginner-in-Charge.

264.63

-

-

... More
15 mm cement plaster in single coat on rough side of brick masonry for interior plastering upto floor two level including arrises, internal rounded angle, chamfers and /or rounded angles not exceeding 80 mm in girth and finished even and smooth with cement mortor 1:3 ( 1 cement :3 sand ) in all leads and lifts as per the direction of the Enginner-in-Charge.

158.88

-

-

... More
20mm cement plaster in single coat in Rough side of interior plastering upto floor two level including arrises,internal,founded angles,chamfers and/or rounded angles chamfers and/or rounded angles not exceeding in girth & finished even and smooth in cement mortar 1:6(1cement:6sand) including carriage of material in all leads & lifts

153.42

-

-

... More
6 mm thick cement plaster in C.M.1:3 to ceiling with in all leads and lifts complete to the entire satisfaction as directed by the Engineer-in-charge.

95.78

-

-

... More
Pointing on brick work with cement mortar 1:3 ( 1 cement : 3 sand) within all leads and lifts complete to entire satisfaction as directed by the Engineer-in-charge

169.9

-

-

... More
P/ F pressed steel door frames manufactured from commercial MS sheets of 1.25mm thickness including hinges, jump lock jamp. Bead and if required angle threshold of MS angle 50 x 25 mm or base tie of 1.25mm pressed MS welded or rigidly fixed together by mechanical means, adjustable lugs with split and tails to each jamp i/c steel butt hinges 2.5mm thick with guards, lock strike plate and shock as specified and applying a coat of steel primer after pretreatment or surface as directed by Engineer-in-charge.

133.42

-

-

... More
Providing and fixing 1mm thick M.S.sheet door with frame of 40mmx40mmx6mm angle iron 3.15mm M.S. gusset plate at the junctions and corners including all necessary fittings, complete including applying a priming coat of red lead paint.using flat 30mm x6mm for diagonal braces and control cross/pieces complete in all respect including carriage of material in all leads & lifts.

23.98

-

-

... More
Providing plinth protection 50mm thick in cement concrete 1:3:6(1cement:3sand:6water borne stone aggregate 20mm nominal size)including finishing the surface of concrete smooth complete in all respect including carriage of material in all leads & lifts.

30.72

-

-

... More
50 mm thick CC 1:2:4 flooring laid in one layer & finished with a floating coat of neat cement complete in all respect including carriage of material in all leads & lifts.

57.94

-

-

... More
40 mm thick CC 1:2:4 flooring laid in one layer & finished with a floating coat of neat cement complete in all respect including carriage of material in all leads & lifts.

39

-

-

... More
Providing 40x3 mm flat iron hold fast 40 cm. Long including fixing to frame with 10 mm diameter bolts nuts and wooden plugs and embeding in cement concrete block 30x10x15cm. 1:3:6 (1 cement : 3 sand : gragded stone aggregate 20mm nominal size) complete in all respect including carriage of material in all leads & lifts.

58

-

-

... More
Providing and fixing M.S. grills of required pettern in windows frames of windows etc. with M. S. Flats Square or round bars with round headed bolts and nuts or by screws. (Plain grill) complete in all respect including carriage of material in all leads & lifts.

202.4

-

-

... More
Providing and fixing M.S.Handles with necessary screws complete in all respect ( 125 mm ) complete in all respect including carriage of material in all leads & lifts.

40

-

-

... More
Providing and fixing M.S.Tower bolts ( Barrel type ) with necessary screws complete in all respect ( 200X10 ) complete in all respect including carriage of material in all leads & lifts.

40

-

-

... More
Providing and fixing sliding door bolts,black enamelled with nuts and screws complete in all respect ( 250X16 ) complete in all respect including carriage of material in all leads & lifts.

6

-

-

... More
P/F on wall face Cast Iron rain water pipe 100mm dia i/c fitting and joints with spun yarn and cement mortar 1:2(1cement:2sand ) including clamps complete in all respect including carriage of material in all leads & lifts.

16

-

-

... More
Applying a priming coat With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works complete in all respect including carriage of material in all leads & lifts.

46.66

-

-

... More
Painting two coats With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) complete in all respect including carriage of material in all leads & lifts.

23.98

-

-

... More
White washing with lime on undecorated wall surfaces two coats to give & even shade i/c thorougly brooming the surface to remove all dirt, dust mortar & other foreign matter. complete in all respect including carriage of material in all leads & lifts.

442.24

-

-

... More
Finishing wall with water proofing cement paint of approved brand & manufacture & of required shade on undecorated wall surfaces ( Two coats) to give an even shade after thoroughly brushing the surface to remove all dirt & remains of loose powdered materials complete in all respect including carriage of material in all leads & lifts.

675.24

-

-

... More
Providing and fixing M.S fan clmp type 1 of 16 mm dia M.S bar bent to shape with hooked ends in R.C.C slab during laying including painting the exposed portion of loop, all as per standard design complete in all respect including carriage of material in all leads & lifts.

6

-

-

... More
Steel work welded in built up sections,trusses & framed work including cutting, hoisting & fixing in position & applying a priming coat of red lead paint In grating, framed, guards, bars, ladders, railing, brackets & similar works within all leads and lifts as per direction of Engineer-in-charge.

208.2

-

-

... More
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant(HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required including carriage of all material within all leads and lifts. Group "C"

30

-

-

... More
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC Conduct along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required including carriage of materials within all leads and lifts.

70

-

-

... More
Wiring for light plug with 2X1.5 Sq. mm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductof cable in PVC casing & capping along with 1 No. 1.5 Sq. mm HRFRLS/PVC insulated single core copper conductor cable for earthing as required including carrige of material with in all leads and lifts.

150

-

-

... More
wiring for sub main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke songle core (flexible) copper conductor cable in PVC casing & capping along with 1 No. 1.5 Sq mm HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required including carriage of material upto all leads an lift 2X2.65 Sq mm.

30

-

-

... More
Supplying & fixing metal box of 180mm.x100mm.x60mm. deep sizes (nominal size) on surface or in recess with suitable for fixing phenolic laminated sheet covered in the front including Providing and fixing 5 pin 5/6 amps socket , outlet and 5/6 amps plano type switch connections painting etc. as required carriage of materials within all leads and lifts.:-

6

-

-

... More
Supplying and fixing bakelite batten/angle holder including connections as required.

8

-

-

... More
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible,cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:-Ceiling Fan 1200 mm sweep, Category-A.

6

-

-

... More
Providing and fixing ultra slim decorative extruded box fixture with domestic electronic ballast, snao-on mstallers suitable for 28 watt FTL (T5), complete with all accessories (excluding one No.T-5 Tube), connections, testing and commissioning etc. as required. 1 x28 watt-FTL(T58) (Category-A)

8

-

-

... More
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, "C" curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required. Double pole CAT-A

6

-

-

... More
Supplying and fixing of following way single pole and neutral sheet steel MCB distribution board 240 volts on surface/recess completed with tinned, copper bus-bar, wire set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification levels interconnections,phosphatized and power painted, including earthing etc. as required Double door 8 way.

6

-

-

... More
Supplying and erection 6 Amps to 32 Amps rating 10 KA Breaking capacity 240 volts C Curves miniature cicuite breaker of following poles in the existing MCB, DB complete with connections testing and commissioning etc. as required Category "A", single pole.

6

-

-

... More
Providing installation testing and commissioning of prewired flourscent tube fitting 1x40 watt box type Cat A i.e Bajaj make complete with balast starter and capacitor but excluding flourscent tube rod suitable to operate on 240 volt single phase AC supply directly on surface with copper wiring as required complete as per direction of the Engineer-in-charge.

8

-

-

... More
Earthing with G.I. earth pipe 4.5 mtrs long, 40mm dia including accessories and providing masonry enclousres with cover plate having locking arrangement and watering pipe etc.( but without charcal coke and salt) complete as required including carriage of materials within all leads and lifts.

2

-

-

... More
Extra for using salt and charcoal for pipe earth electrode complete as required, including carriage of materials within all leads and lifts.

2

-

-

... More
Supplying and laying 6 SWG G.I.wire at 0.50 mtr below ground level for earth electrode including soldering etc. as required including carriage of materials within all leads and lifts.

80

-

-

... More
Providing, fixing & testing Street Light Fixture with CFL of 36 watt, copper ballast, G.I. Pipe bracket, complete in all respects.

4

-

-

... More
Providing & Laying, jointing and testing in trenches following dia and grade having suitable pressure Kg.F/ cm2 working pressure polythene pipes high density conforming to IS: 4984-1995 complete but ends preparead for Heat/Electric joints including testing of Joints complete( Earth work in trenches to be measured and paid for separately) within all leads and lifts and as per direction of Engineer-in-charge.180 mm dia HDPE pipe class PE-80, grade PN 4.00

4705

-

-

... More
Providing. and fixing Cast Iron Alfa valves of reputed & approved make like Kirloskar/Leaderetc. on distribution system of confirming to IS: with latest ammendments of appropriate class & following dia metre and capable to with stand the requisite nominal seat pressure 10Kg/ Sqmt including testing and upto entire satisfaction of Engineer -in-Charge 200 mm dia

39

-

-

... More
,Laying, jointing and testing in trenches Galvanized mild steel flanged/butt welded pipes below mentioned dia and grade conforming to IS:1239-2004 (with latest amendments)The MS Flanges are to be provided for 5% of total joints as per table below conforming to IS:6392-1971 (latest upto date amendments) and welding of MS flanges with pipe as per IS: 816-1969 with electrodes as per IS:814-1991 including required number and size of MS nuts and bolts as per IS 1369-1967 and compressed asbestos fibre jointing gaskets sheet not less than 3.00mm in thickness as per IS:27121-1965. The welding of flanges to be done on both faces in three layers in each face to make the joints leak proof including all kind of specials such as bends of all degrees to be made from parent tube, short pieces, tail pieces all made from parent tube and to the entire satisfaction of the Engineer-in-Charge. The pipes end should be bevelled suitable for butt welding. the circumferencial butt welded joints (95% of the total joints) by electrical arc welding to following dia & class pipes, welding of pipes to be done in three layers to make joints leak proof and to achieve the minimum effective throat thickness of welded conforming to IS 816-1969 specifications, by using welding electrode of 2.5mm to 6.3 mm of Advani oerlikon (Adore)-CITOJET/ESAB make conforming to IS 814-1991, at site of work complete in all respect and including DPT test for joints & manual/mechanical handling of pipes.The laying of Pipes conform to IS 5822 (with latest ammendentments upto date) including all kind of specials such as bends of all degrees to made from parent tube, short pieces, tail pieces all amde from parent tube within all leads and lifts (Earth work in trenches, MS flanges and butt welded joints to be measured and paid for seperately) ) (RD 0to 560.)=560 Rmtrs. GMS pipe 150 mm dia ( Medium grade) 4.80 mm thick

560

-

-

... More
Providing, welding and fixing of MS flanges @ 5% of total joints conforming to table as specified below of BIS-6392-1971 ( Latest with upto date ammendments) welding of M.S. flanges on ( Two layers on inner face and one layer on outer face of each flange) with GMS pipes and bends on both ends. ( The GMS pipe to be measured and paid for separately. ) The welding of flanges should conforming to IS 816-1998 with electrodes as per IS 814-1997, Prov.& fixed with nuts, bolts of required size conforming to IS 1364, including providing & fixing 3 mm (Minimum) thick compressed asbestos fibre / synthetic rubber gasket conforming relevant BIS Code IS 2712-1965( The earth work in trenches to be measured and paid for seperately) complete in all respect and including entire carriage of materials in all leads and lifts as per the direct1on of the Engineer-in-Charge MS Flanges 150 mm dia Table- 5

5

-

-

... More
Providing circumferential butt welded joints @ 95% by electrical are welding to GMS ERW pipe welded in rerqusite number of weld runs so as to achiev the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welging electrodeds of 2.5 mm to 6.3 mm of Advani Oeriliken ( adore)-CITOJET/ES/ESAB make conforming to IS 814-1991 include Die pentration test at site of work complete in all respects, including manual/ mechanical handling of pipe in all leads asnd lifts to the entire satisfaction of Engineer-in- charge.150mm dia. GMS pipe 150 mm dia 4.80 mm thick

88

-

-

... More
Tubewell 34 NAKROH.Supply and errection of submersible pumping set of reputed make such as KSB/ Calama / BS/ Worthigton / Groundfos/ LUBI /Hindustan/ Sabar/Seerex/Johnston / Amrut, conforming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ;5659-1978 with upto date amendments, suitable for raw /clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications The pump shall be directly coupled to submersible squirrel cage electric induction motor of same make conforming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed,lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear and tear.It should also be fitted with a device to make up expa-of water with heating of motor The pumpset should include water level guard i/c cable ,errection clamps, cable clips and suitable for opertion on data given below. Specifications offered a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation

1

-

-

... More
Discharge, (Q) 15.36 LPS

-

-

-

... More
Total Head ( H ) 59.66 Mts.

-

-

-

... More
SWL in Tubewell 33.85 mtr. bgl.

-

-

-

... More
R.L. point of discharge 100.75 mtr

-

-

-

... More
R.L. of Pump House = 100.01 mtr.

-

-

-

... More
Seasonal fluctuation + draught condition + bowl assembly.9.00 mtrs.

-

-

-

... More
Drawdown in Tubewell 10.67 mtrs.

-

-

-

... More
StaticHead = 54.20 mtrs.

-

-

-

... More
Static column lift 46.47 mtrs.

-

-

-

... More
Rising main Column pipe

-

-

-

... More
Length 20 mtrs Length 63.52 mtr

-

-

-

... More
Dia 150 mm (M) Dia 125mm (M)

-

-

-

... More
Class GMS (M)

-

-

-

... More
iv) Pumping hours 4637.92 hours

-

-

-

... More
v) Alititude of installations above M.S.L 100mtr

-

-

-

... More
vi) Characteristic of water

-

-

-

... More
(vii) Temperature : 20.00 Deg. C

-

-

-

... More
(viii) Ambient temperature 42.00 Deg. C

-

-

-

... More
(ix) Turbidity than 50.00 NTU

-

-

-

... More
(x) Alkalinity Mg/Ca Co3

-

-

-

... More
(xi) Size of the solids mm

-

-

-

... More
xii) others

-

-

-

... More
xiii) Depth of T/well 150 mtr

-

-

-

... More
ix) Dia of T/well assembly 300/200 mm

-

-

-

... More
Length of assembly pipe

-

-

-

... More
Dia of housing pipe

-

-

-

... More
Length of housing pipe

-

-

-

... More
OPERATING CONDITIONS

-

-

-

... More
i) Type of current A.C Three phases.

-

-

-

... More
ii) Frequency 50 Cycles/ Sec.

-

-

-

... More
iii) Rated Voltage 415+/-10% Volts

-

-

-

... More
iv) System of earthing Double Loop earthing as per BIS 3843-1987 latest

-

-

-

... More
v) Speed of Revolution __________________ RPM 2900

-

-

-

-

-

-

... More
i) Ref to BIS code BIS 9283-1979 with upto date amendments

-

-

-

... More
ii) Type of enclousre of motr As per BIS :4691-1985 (latest)

-

-

-

... More
iii) Mechnical out put in HP

-

-

-

... More
iv) Class of insulation : Class B The motor should be able to withstand intial current of 2.50 times the rated current for two minutes without suffering damages of permanet deformations

-

-

-

-

-

-

... More
i) Ref to BIS code BIS 5659-1978 with upto date amendments

-

-

-

... More
ii) Driver Type Electric drivern

-

-

-

... More
iii) Operating Range -25%to +10% of Total head at duty point

-

-

-

... More
iv) Deliver size of Pump ;---------- (to be quoted by tenderer)

-

-

-

... More
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 13947- P I & II with upto date amendments. i) Make : ii) Type : iii) Capacity : 63 amp.

1

-

-

... More
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. Panel/ Switch Board i) Drawing. ii) Layout Plan

1

-

-

... More
MCB of kilburn / L&T/ Havells make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. i) Make : ii) Type : iii) Range 63 amp. iv) Capacity

1

-

-

... More
ELCB of recommended make L&T /Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELCB i) Make : ii) Type : iii) Range 63 Amp. iv) Capacity

1

-

-

... More
The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage, reverse phasing, overloading and phase voltage difference as per IS; 3842 ( Latest Edition )i) Make : ii) Type : iii) Range 0-500

1

-

-

... More
A.C. supply, voltmeter of recommended make A.E./ L&T /Havells of suitable range with selector switches as per IS ;1248-1983 with latest amendments. Voltmeter i) Make : ii) Type : iii) Range 0-500.

1

-

-

... More
AC supply ammeter of A.E / L&T/ Havells make of suitable range with selector switches and CIS operated as per IS :1248 ( P-I&II ) -1983 with upto date amendments. Ammeter i) Make : ii) Type : iii) Capacity 60 Amp.

1

-

-

... More
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ; 8084-1976 and IS : 11353-1985 read with BIS ; 5578 -1985 with upto date amendments including.Three phase indicator lamps complete with toggle switches for individual motors as per IS 3452 (P- I&II ) with upto date amendments. 3 Phase indicators 3 phase indicators i) Make : ii) Type : iii) Rating

1

-

-

... More
Capacitor of BHEL / L&T make as per IS ; 2834-1968 with upto date amendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/ IEC make) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments .Rate of capacitor will be approved by HPSEB. i) Make : ii) Type : iii) Range. 6 KVAR

1

-

-

... More
Providing suitable Star delta starter of L&T/Havell's /MEI/BHEL/Kilburn make as per IS: 13947-II with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. Single Phase Preventor i) Make : ii) Type : iii) Range.

1

-

-

... More
Single Phase Preventor i) Make : ii) Type : iii) Range.

1

-

-

... More
Providing and fixing double flanged Cast iron Sluice valve of Leader / Kartar/ Kirloskar /LP/RG Brand make for the delivery line of pump and capable of withstanding the normal seat pressure and as per IS :- 780-1992 with latest ammendments i) Make : ii) Type : iii) Make :- Cast Iron Class PN-1.00 for Column Pipe 125 mm dia

1

-

-

... More
Providing and fixing double flanged swing type cast Iron Reflux valve of Leader/ Kirloskar/Kartar / LP/RG Brand make having Bye pass arrangement on the delivery line of the Pump and capable of 'withstanding normal Seat Pressure as per IS: 5312 Part-1 with latest ammendments i) Make : ii) Material : Cast Iron iii) Class PN-1.00 For for R/main 150 mm dia.

1

-

-

... More
Providing and fixing pressure gauge of Prega / Precision make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements. i) Make :

1

-

-

... More
Supply of PVC Jointless , Flat water proof cables as per BIS 694-1998 Latest with upto date amendments , Suaitable for the pump set offered from MCB to Motor Including all other electrical equipments / accessories such as thimble , flexible pipe solder , nuts and bolts , cable glands etc . laid in pipes or trenches under floor .The tpye size and make shall be subject to approved of HPSEB authorities . i) Make : Finolex/ Havells ii) Size 3 x 6 mm2 copper iii). type- IV capacity V Core-).

127.04

-

-

... More
Lowering of GMS Column pipefor assembly 100 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber/asbestos gasket of min. 3mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 . The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No. 70 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main . The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. (The pipe shall be supplied by the Department free of cost from Divisional Store Badoh(Gagret). Column Pipe 100 mm dia GMS pipe (M)

63.52

-

-

... More
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.

1

-

-

... More
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 (P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay /Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts, cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply Side From meter of HPSEB to Bus Bar and Switch)Armoured Power Cable (A) Motor side (From Switch to Starter & Starter to motor) i) Size 6.00 mm2 ii) Make iii)Type iv) Capacity v) Core 3

1

-

-

... More
(B) Supply Side (From meter of HPSEB to Bus Bar & Switch) i) Size 3x16.00 mm2 ii) Make iii) Type iv) Capacity v) Core 3

1

-

-

... More
Providing and fixing double loop earthing with Cooper Plateand Suitable thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt, as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge. i) i) Copper Wire 8.SWG upto 30 HP .

1

-

-

... More
Tubewell 30 GONDPUR BANEHRA.Supply and errection of submersible pumping set of reputed make such as KSB/ Calama / BS/ Worthigton / Groundfos/ LUBI /Hindustan/ Sabar/Seerex/Johnston / Amrut, conforming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ;5659-1978 with upto date amendments, suitable for raw /clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications The pump shall be directly coupled to submersible squirrel cage electric induction motor of same make conforming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed,lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear and tear.It should also be fitted with a device to make up expa-of water with heating of motor The pumpset should include water level guard i/c cable ,errection clamps, cable clips and suitable for opertion on data given below. Specifications offered a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation

1

-

-

... More
Discharge, (Q) 20.98 LPS

-

-

-

... More
Total Head ( H ) 76.93 Mts.

-

-

-

... More
SWL in Tubewell 21.35 mtr. bgl.

-

-

-

... More
R.L. point of discharge 110.65 mtr

-

-

-

... More
R.L. of Pump House = 99.20 mtr.

-

-

-

... More
Seasonal fluctuation + draught condition + bowl assembly.9.00 mtrs.

-

-

-

... More
Drawdown in Tubewell 18.30 mtrs.

-

-

-

... More
StaticHead = 60.10 mtrs.

-

-

-

... More
Static column lift 50.55 mtrs.

-

-

-

... More
Rising main Column pipe

-

-

-

... More
Length 540 mtrs Length 58.65 mtr

-

-

-

... More
Dia 150 mm (M) Dia 125mm (M)

-

-

-

... More
Class GMS (M)

-

-

-

... More
iv) Pumping hours 4637.92 hours

-

-

-

... More
v) Alititude of installations above M.S.L 100mtr

-

-

-

... More
vi) Characteristic of water

-

-

-

... More
(vii) Temperature : 20.00 Deg. C

-

-

-

... More
(viii) Ambient temperature 42.00 Deg. C

-

-

-

... More
(ix) Turbidity than 50.00 NTU

-

-

-

... More
(x) Alkalinity Mg/Ca Co3

-

-

-

... More
(xi) Size of the solids mm

-

-

-

... More
xii) others

-

-

-

... More
xiii) Depth of T/well 150 mtr

-

-

-

... More
ix) Dia of T/well assembly 300/200 mm

-

-

-

... More
Length of assembly pipe

-

-

-

... More
Dia of housing pipe

-

-

-

... More
Length of housing pipe

-

-

-

... More
OPERATING CONDITIONS

-

-

-

... More
i) Type of current A.C Three phases.

-

-

-

... More
ii) Frequency 50 Cycles/ Sec.

-

-

-

... More
iii) Rated Voltage 415+/-10% Volts

-

-

-

... More
iv) System of earthing Double Loop earthing as per BIS 3843-1987 latest

-

-

-

... More
v) Speed of Revolution __________________ RPM 2900

-

-

-

-

-

-

... More
i) Ref to BIS code BIS 9283-1979 with upto date amendments

-

-

-

... More
ii) Type of enclousre of motr As per BIS :4691-1985 (latest)

-

-

-

... More
iii) Mechnical out put in HP

-

-

-

... More
iv) Class of insulation : Class B The motor should be able to withstand intial current of 2.50 times the rated current for two minutes without suffering damages of permanet deformations

-

-

-

-

-

-

... More
i) Ref to BIS code BIS 5659-1978 with upto date amendments

-

-

-

... More
ii) Driver Type Electric drivern

-

-

-

... More
iii) Operating Range -25%to +10% of Total head at duty point

-

-

-

... More
iv) Deliver size of Pump ;---------- (to be quoted by tenderer)

-

-

-

... More
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 13947- P I & II with upto date amendments. i) Make : ii) Type : iii) Capacity : 100 amp.

1

-

-

... More
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. Panel/ Switch Board i) Drawing. ii) Layout Plan

1

-

-

... More
MCB of kilburn / L&T/ Havells make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. i) Make : ii) Type : iii) Range 100 amp. iv) Capacity

1

-

-

... More
ELR of recommended make L&T /Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELR i) Make : ii) Type : iii) Range 100 Amp. iv) Capacity

1

-

-

... More
The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage, reverse phasing, overloading and phase voltage difference as per IS; 3842 ( Latest Edition )i) Make : ii) Type : iii) Range 0-500

1

-

-

... More
A.C. supply, voltmeter of recommended make A.E./ L&T /Havells of suitable range with selector switches as per IS ;1248-1983 with latest amendments. Voltmeter i) Make : ii) Type : iii) Range 0-500.

1

-

-

... More
AC supply ammeter of A.E / L&T/ Havells make of suitable range with selector switches and CIS operated as per IS :1248 ( P-I&II ) -1983 with upto date amendments. Ammeter i) Make : ii) Type : iii) Capacity 100 Amp.

1

-

-

... More
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ; 8084-1976 and IS : 11353-1985 read with BIS ; 5578 -1985 with upto date amendments including.Three phase indicator lamps complete with toggle switches for individual motors as per IS 3452 (P- I&II ) with upto date amendments. 3 Phase indicators 3 phase indicators i) Make : ii) Type : iii) Rating

1

-

-

... More
Capacitor of BHEL / L&T make as per IS ; 2834-1968 with upto date amendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/ IEC make) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments .Rate of capacitor will be approved by HPSEB. i) Make : ii) Type : iii) Range. 9 KVAR

1

-

-

... More
Providing suitable starter of L&T/Havell's /MEI/BHEL/Kilburn make as per IS: 13947-II with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. Single Phase Preventor i) Make : ii) Type : iii) Range.

1

-

-

... More
Single Phase Preventor i) Make : ii) Type : iii) Range.

1

-

-

... More
Providing and fixing double flanged Cast iron Sluice valve of Leader / Kartar/ Kirloskar /LP/RG Brand make for the delivery line of pump and capable of withstanding the normal seat pressure and as per IS :- 780-1992 with latest ammendments i) Make : ii) Type : iii) Make :- Cast Iron Class PN-1.00 for Column Pipe 125 mm dia

1

-

-

... More
Providing and fixing double flanged swing type cast Iron Reflux valve of Leader/ Kirloskar/Kartar / LP/RG Brand make having Bye pass arrangement on the delivery line of the Pump and capable of 'withstanding normal Seat Pressure as per IS: 5312 Part-1 with latest ammendments i) Make : ii) Material : Cast Iron iii) Class PN-1.00 For for R/main 150 mm dia.

1

-

-

... More
Providing and fixing pressure gauge of Prega / Precision make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements. i) Make :

1

-

-

... More
Supply of PVC Jointless , Flat water proof cables as per BIS 694-1998 Latest with upto date amendments , Suaitable for the pump set offered from MCB to Motor Including all other electrical equipments / accessories such as thimble , flexible pipe solder , nuts and bolts , cable glands etc . laid in pipes or trenches under floor .The tpye size and make shall be subject to approved of HPSEB authorities . i) Make : Finolex/ Havells ii) Size 3 x 16 mm2 copper iii). type- IV capacity V Core-).

117.3

-

-

... More
Lowering of GMS Column pipefor assembly 100 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber/asbestos gasket of min. 3mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 . The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No. 70 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main . The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. (The pipe shall be supplied by the Department free of cost from Divisional Store Badoh(Gagret). Column Pipe 125 mm dia GMS pipe (M)

56.65

-

-

... More
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.

1

-

-

... More
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 (P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay /Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts, cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply Side From meter of HPSEB to Bus Bar and Switch)Armoured Power Cable (A) Motor side (From Switch to Starter & Starter to motor) i) Size 6 mm2 ii) Make iii)Type iv) Capacity v) Core 3

1

-

-

... More
(B) Supply Side (From meter of HPSEB to Bus Bar & Switch) i) Size 3x 25.00 mm2 ii) Make iii) Type iv) Capacity v) Core 3

1

-

-

... More
Providing and fixing double loop earthing with Cooper Plateand Suitable thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt, as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge. i) i) Copper Wire 14.SWG beyond 35 HP or 50HP.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.