Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date21 Feb 2025
Closing Date4 Mar 2025
Tender Amount₹ 2,42,66,187 
Notes
Download

AI Insights

Technical Capacity
... View More
The bidder is required to have experience in providing and fixing of pumping machinery, as well as experience in Construction of Water Retaining Structure. They should upload a list of such works. However, specific values like amount and percentage of similar works completed are not mentioned.

Costs

Summary

Augumentation Of Lwss Thountha Jakhal In Shillai Constituency Tehsil Kamroo District Sirmour Under Nabard

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Capacity (in LPS) : 9.62 LPS

-

-

-

... More
Dia of R/Main (in mm) 125 MM

-

-

-

... More
Length of rising main (in mtr.) 330 meters

-

-

-

... More
2*17.50 HP = 35 HP

-

-

-

... More
Providing and fixing of auto control panel with push button star delta starter( 2 Nos.) for submersible pump of L&T and reputed make fabricated with M.S. sheet and angle stand duly painted and complete with internal wiring, comprising of main switch of suitable Amp., T.P. volte meter, copper busbar, ameter, hour run metre, phase indicating lamps with GMS based, remote start/stop operation call/SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hour in a day, imbuilt protection against overload/ undervoltage, dry run, single phase preventer, inbuilt GPS tracker, phase reversal configurable volt/current limits with a facility to access the system through minimum 10 No. authenticate mobile Nos. complete in all respect, including intire carriage of materials all leads and lifts, installation and testing at site with entire saisfaction of engineer-in-incharge.(all meters to be installed shall be DIGITAL)

1

-

-

... More
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of Cast steel double flanged sluice valve having size one size higher than the nominal dia. of the pump or equal to dia. of column pipe (in case of t/well) and capable of withstanding nominal seat pressure as mentionmed in item No. 1 (a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump.class of valve shall be ASA 150.

2

-

-

... More
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make of suitable size cast steel double flanged swing check type reflux valve having bye pass arrangement & size one size larger than the nominal diameter of delivery size of pump or equal to dia. of column pipe (in case of t/well) and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a)+ surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump. class of valve shall be ASA 150.

2

-

-

... More
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ICC/EICO/National /IEC make from meter of HPSEB to circuite breaker & from circuite breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.

10

-

-

... More
Providing and laying at site PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date amendments) suitable for both the pump sets offered from circuite breaker to motor & motor to starter including all other electrical equipments such as thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.

45

-

-

... More
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.

1

-

-

... More
Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T/Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).

2

-

-

... More
PrOviding and lowering GMS (medium Grade) column pipe assembly of 125mm dia, 4.80 mm thickness Including MS flanges of Table-17 as per IS-3183-2007 with up to date amendments, rubber/asbestos gasket of maximum 3 mm thickness as per IS: 2712-19/9 and required numbers of nuts and bolts as per IS: 1364-1983. The column pipe shall be as per relevent IS: code and to with stand 1.5 times total head stipulated under item no- 1(a). The column pipe shuld be extended up to 5 mtrs. beyond the outer wall of the pumphouse in the direction of Rising main. The column pipe should be properly jointed with the Rising main including all neccessary accessaries like |increaser/reducer, flanges, tees, bends etc. including supporiing clamps (2 nos) at the top of assembly and conforming and as per the dire ction of engineer-in-charge.

1

-

-

... More
Pumping Machinery 1st Stage

-

-

-

... More
Supply, erection, testing & commissioning of horizontal spindle, horzontal split casing radial split single /multistage centrifugal pumps of standard make such as KSB/ Mather & Platt/ Jyoti/ Kiroskar /Beaconweir/ BS & BE conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to handel clear water having characteristics as mentioned below in ltem no 8(A), with impelleres,casing ring priming funnels & shaft sleeves of bronze , shaft of steel of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel/ Mild steel to BHEL/ Kirlokar/ NGEF/Crompton/Siemen /jyoti/GEC make slip ring /squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below i/c the cost of all the accessories in all leads and lifts & carriage at the site sites as per direction of Engineer-in - charge. :- (Note:- Tender to be called for per set not for per HP rate)

2

-

-

... More
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 475.50 mtr

-

-

-

... More
Capacity (in LPS) : 9.62 LPS

-

-

-

... More
Dia of R/Main (in mm) 125 MM

-

-

-

... More
Length of rising main (in mtr.) 1720 metres

-

-

-

... More
2*120 HP = 240 HP

-

-

-

... More
Supply, installation, Testing and Commissioning of Fully Autometic LT Panel for centrifugal pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opening door type switch board with copper insulated wiring suitable to operate 2 No. pump of rating 120HP automatically through variable Frenqency Drive Starter. Starter should be capable to handle all rth faults like short circuit, over current. under current, over voltage, under voltage, dry pump protection. It should get on and off command automatically from PLC and HMI. Monitoring and controlling of Pump running and trippng status should be monitored and controlled remotely through IOT enabled device. Access shoild be given to 3 users. Reputed make.

1

-

-

... More
Energy saving variable freqency drive starter of suitable HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It should be cable to control the frequecy of pumps through out the opration and also should be cabable to maintain the power factor of the system within acceptable limits. It should be able to withstand ambient temprature 50 Degree ceicius without derating and have conformal coating class 3C2. so that it can work in any harsh enviroment like moisture etc. make:-L&T/conserve/schmeder/Aarmation 1 No. 3 ii) Main incomer MCCB of suitable capacity of L&T/schmeder/ABB/ Siemens make on the coming feeder for pumping set confirming to BIS-2516-1985 (Latest edition) 1 No 3 (iii) LED Three phase indicating lamps complete with logged switch for indivisual motore confrming to BIS 3452 (Part I & II) latest with up to date amendments 1 No. 3(iv) LED On/Off Lincommer MCCB with proper short circuit capablility for both the starter make L&T/schmeder/ABB (1 No) 3(v) On/Off & Trip indicator and push button, control and power wiring Power capacitor, cooling fan 230 VAC control terminal, Buss Bar i.e. Bolt insulator etc. (1 No ), 3(vi) selector switch for Auto and Manual oparation 1 No. 3(vii) Input Choke of required HP for Energy saving variable frequency starter which should be installed at the input of Energy saving variable frequency starter, so that there whould be proper protection in case of any voltage surge and distortons 2 No. 3(viii) ControlTransformer Make Surge supressor device with isolating MCCB to circunate the power surges due to lightening and system surges 1 No. 3(ix) Power and control Wiring and Busbar 1 No. 3(x) Installation, commissining and Software Development 1 No. 3(xi) Surge supressor device with isolating MCCB toeleminate the power surge due to lightening and system surge 1 No. 3(xii) Insdependent Control Panel with stiwth Fuse Unit and Fuses to Suitable Amperage to eliminate the Kit Kat fuses of HPSEB Make: Aarmaton/Siemens/Schnieder/L&T 1 No Automation System for Unmannede Operation with SCADA features, PLC, HMI and Level Sensor:- (i) PLC (Programmable logic controller) with appropriate digital and analog and inputs and output to give automatic command to Star Delta Starter Panel/ Energy Saving Variable Frequency Starter Panel Make Aarmation Electric bechoff automation/Rockwell Automation 1 No. (ii) Electronic relay card & channel 1 No. (iii) SMPS 4.5 Amps to energise PLC system, (iv) HMI (Human Machine Interface) 7" display for Monitoring and Controlling of Centrifugal pumps Make Aarmation electric/Bechoff Automation/Rockwell 1 No. (v) Control MCB for Automation system 1 No (vi) Level Sensor to indicate the water level of tank remotely 1 No (vii) Shielded Data Cable for Communication of level Sensor with PLC 1 No. (viii) Supply of Mobile App (Android IOS) with User ID and Password to monitor and control the pumping opeartion from Mobile for 3 users Make Aarmation electric/Bechoff Automation/Rockwell Automation(ix) Could Gate way for Data Clouding to server 1 No (x) SCADA soft ware to be installed in Laptop/PC on remotely monitor and control the operation of pumps and also to anysis the pump start and stop history logging fuilt starter, fault history, Power quality Parameters like PE urrent Votage KWH THD etc. Make Aarmation electric/Rockwell automation Rockwell 1 No (xi) Cloud space for data storage at cloud/server 1 No (xii) Installation Commissining and Software Development.

1

-

-

... More
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of Cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 8 (a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump.class of valve shall be ASA 600.

2

-

-

... More
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make of suitable size cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size larger than the nominal diameter of delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 8(a)+ surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump .class of valve shall be ASA 600.

2

-

-

... More
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make of suitable size Cast steel double flanged swing check type reflux valve confirming to API standard with up to date ammendments for R/main as mentioned in item No. 8 (c) for withstanding nominal seat pressure as per item No. 8(a) + surge pressure.The size of reflux valve shall be equal to size of Rising main and the provided with suitable bye pass arrangements. class of valve shall be ASA 600 and shall be of 125mm diameter.

1

-

-

... More
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make Cast iron double flanged sluice valve (in case suction is +ve) for suction pipe having size one or two size of pump such that velocity of flow in suction pipe is not more than 3.00 mtr/sec and confirming to BIS standatds with up to date ammendments.class of valve shall be PN 1.60

2

-

-

... More
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ICC/EICO/National /IEC make from meter of HPSEB to circuite breaker & from circuite breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.

10

-

-

... More
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.

30

-

-

... More
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.

1

-

-

... More
Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).

2

-

-

... More
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc.conforming to BIS 3624-1987 or latest with up to date ammendments.

2

-

-

... More
P/F double flanged suction, delivery pipe & common header of MSERW pipe Grade-B considering site requirements, NPSH reauired & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 9 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump Thickness of MSERW pipe shall be 6.60 mm with flanged joint of FT- 34.

1

-

-

... More
Pumping Machinery 2nd Stage

-

-

-

... More
Supply, erection, testing & commissioning of horizontal spindle, horzontal split casing radial split single /multistage centrifugal pumps of standard make such as KSB/ Mather & Platt/ Jyoti/ Kiroskar /Beaconweir/ BS & BE conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to handel clear water having characteristics as mentioned below in ltem no 15(A), with impelleres,casing ring priming funnels & shaft sleeves of bronze , shaft of steel of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel/ Mild steel to BHEL/ Kirlokar/ NGEF/Crompton/Siemen /jyoti/GEC make slip ring /squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below i/c the cost of all the accessories in all leads and lifts & carriage at the site sites as per direction of Engineer-in - charge. :- (Note:- Tender to be called for per set not for per HP rate)

2

-

-

... More
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 271.50 mtr

-

-

-

... More
Capacity (in LPS) : 6.64 LPS

-

-

-

... More
Dia of R/Main (in mm) 100 MM

-

-

-

... More
Length of rising main (in mtr.) 975 metres

-

-

-

... More
2*50 HP = 100 HP

-

-

-

... More
Supply, installation, Testing and Commissioning of Fully Autometic LT Panel for centrifugal pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opening door type switch board with copper insulated wiring suitable to operate 2 No. pump of rating 50 HP automatically through variable Frenqency Drive Starter. Starter should be capable to handle all rth faults like short circuit, over current. under current, over voltage, under voltage, dry pump protection. It should get on and off command automatically from PLC and HMI. Monitoring and controlling of Pump running and trippng status should be monitored and controlled remotely through IOT enabled device. Access shoild be given to 3 users. Reputed make.

1

-

-

... More
Energy saving variable freqency drive starter of suitable HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It should be cable to control the frequecy of pumps through out the opration and also should be cabable to maintain the power factor of the system within acceptable limits. It should be able to withstand ambient temprature 50 Degree ceicius without derating and have conformal coating class 3C2. so that it can work in any harsh enviroment like moisture etc. make:-L&T/conserve/schmeder/Aarmation 1 No. 3 ii) Main incomer MCCB of suitable capacity of L&T/schmeder/ABB/ Siemens make on the coming feeder for pumping set confirming to BIS-2516-1985 (Latest edition) 1 No 3 (iii) LED Three phase indicating lamps complete with logged switch for indivisual motore confrming to BIS 3452 (Part I & II) latest with up to date amendments 1 No. 3(iv) LED On/Off Lincommer MCCB with proper short circuit capablility for both the starter make L&T/schmeder/ABB (1 No) 3(v) On/Off & Trip indicator and push button, control and power wiring Power capacitor, cooling fan 230 VAC control terminal, Buss Bar i.e. Bolt insulator etc. (1 No ), 3(vi) selector switch for Auto and Manual oparation 1 No. 3(vii) Input Choke of required HP for Energy saving variable frequency starter which should be installed at the input of Energy saving variable frequency starter, so that there whould be proper protection in case of any voltage surge and distortons 2 No. 3(viii) ControlTransformer Make Surge supressor device with isolating MCCB to circunate the power surges due to lightening and system surges 1 No. 3(ix) Power and control Wiring and Busbar 1 No. 3(x) Installation, commissining and Software Development 1 No. 3(xi) Surge supressor device with isolating MCCB toeleminate the power surge due to lightening and system surge 1 No. 3(xii) Insdependent Control Panel with stiwth Fuse Unit and Fuses to Suitable Amperage to eliminate the Kit Kat fuses of HPSEB Make: Aarmaton/Siemens/Schnieder/L&T 1 No Automation System for Unmannede Operation with SCADA features, PLC, HMI and Level Sensor:- (i) PLC (Programmable logic controller) with appropriate digital and analog and inputs and output to give automatic command to Star Delta Starter Panel/ Energy Saving Variable Frequency Starter Panel Make Aarmation Electric bechoff automation/Rockwell Automation 1 No. (ii) Electronic relay card & channel 1 No. (iii) SMPS 4.5 Amps to energise PLC system, (iv) HMI (Human Machine Interface) 7" display for Monitoring and Controlling of Centrifugal pumps Make Aarmation electric/Bechoff Automation/Rockwell 1 No. (v) Control MCB for Automation system 1 No (vi) Level Sensor to indicate the water level of tank remotely 1 No (vii) Shielded Data Cable for Communication of level Sensor with PLC 1 No. (viii) Supply of Mobile App (Android IOS) with User ID and Password to monitor and control the pumping opeartion from Mobile for 3 users Make Aarmation electric/Bechoff Automation/Rockwell Automation(ix) Could Gate way for Data Clouding to server 1 No (x) SCADA soft ware to be installed in Laptop/PC on remotely monitor and control the operation of pumps and also to anysis the pump start and stop history logging fuilt starter, fault history, Power quality Parameters like PE urrent Votage KWH THD etc. Make Aarmation electric/Rockwell automation Rockwell 1 No (xi) Cloud space for data storage at cloud/server 1 No (xii) Installation Commissining and Software Development.

1

-

-

... More
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of Cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 15 (a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump.class of valve shall be ASA 300.

2

-

-

... More
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make of suitable size cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size larger than the nominal diameter of delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 15(a)+ surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump .class of valve shall be ASA 300.

2

-

-

... More
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make of suitable size Cast steel double flanged swing check type reflux valve confirming to API standard with up to date ammendments for R/main as mentioned in item No. 15 (c) for withstanding nominal seat pressure as per item No. 15(a) + surge pressure.The size of reflux valve shall be equal to size of Rising main and the same shall be provided with suitable bye pass arrangements. .class of valve shall be ASA 300. and shall be of 100 mm dia.

1

-

-

... More
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make Cast iron double flanged sluice valve (in case suction is +ve) for suction pipe having size one or two size of pump such that velocity of flow in suction pipe is not more than 3.00 mtr/sec and confirming to BIS standatds with up to date ammendments. .class of valve shall be PN 1.60.

2

-

-

... More
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ICC/EICO/National /IEC make from meter of HPSEB to circuite breaker & from circuite breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.

10

-

-

... More
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.

30

-

-

... More
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.

1

-

-

... More
Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).

2

-

-

... More
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc.conforming to BIS 3624-1987 or latest with up to date ammendments.

2

-

-

... More
P/F double flanged suction, delivery pipe & common header conforming to MSERW Grade A of IS/ISO3183-2007 specificationor latest with upto date ammendments considering site requirement, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house,sumpwell and jointing of delivery pipe with rising main as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 15e(ii). or total dynamic pressure + surge pressure whichever is higher. The size of suction pipe shall be one or two size larger than nominal suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec.& delivery pipe shall be of size one size larger than nominal delivery size of pump. Thickness of MSERW pipe shall be 4.80 mm jounted with flanged joint of FT -28. ( Actual laying to be done as per final drawing to be approved by the Engineer incharge).

1

-

-

... More
Rising Main & Distribution System

-

-

-

... More
Excavation in drain and channels etc. in earth work for pipes up to all depths in all classification of earthwork such as pick work, jumper work, saturated soil including bailing or pumping out water, blasting soft/hard rock or chiseling soft/hard rock where blasting is prohbited in all lifts including jungle clearance required, trimming & dressing of sides, leveling of beds to ciorrect grade including shoring/struting, planking, timbering & dewatering where required stacking the useable/unuseasble material/soil seperately & after laying, jointing & testing of pipes, returning the useable soil in trenches in 15 cm with in all leads & lifts including restoration of un-metalled surfaces to its original condition& including with in all leads & lifts as per direction of the Engineer-in-Charge.

2766.38

-

-

... More
Rising Main

-

-

-

... More
Providing, laying, testing & commissioning at site in trenches bevelled ended MSERW pipe of various Grades conforming to IS/ ISO 3183-2017 latest with upto date amendements having wall thickness as specified below & capable of withstanding required test pressure as prescribed in IS/ISO code, in random lenghts of 5.5 to 6.5 mtr. The pipes ends shall be bevelled suitable for butt welding including the cost of jointing with butt welding conforming to IS 816-1969 or latest as applicable ends with upto date amendments (leak proof) in three layers at site of work with welding rods of Advani/oeriliken make /IST marked (welded rods 3mm to 4mm) and all allied accessories whatever required for welding at site, tail pieces, tees, bends and other specials manufactured from parent pipes as applicable to the particular each & of approved specification as per site conditions and cutting of pipes wherever required as per site requirement including carriage in all leads and lifts and as directed by Engineer-in-charge. The pipe shall haves zinc coating inside & out side conforming to IS-4736-1986 or latest with upto date amendment & shall be engaged with MSERW pipe Grade-B/Grade A. The laying shall conform to BIS 5822-1970 or latest with upto date amendments to the entire satisfaction of Engineer-in-charge (Earth work & cost of MS Flanges after 90 meter lengh shall be measured & paid for separately) including all leads, lifts and carriage of material at site as per direction and to the entire satisfaction of the Engineer-in charge.

-

-

-

... More
1st Stage

-

-

-

... More
Dia Grade RD to RD wall thickness

-

-

-

... More
125mm Grade -B 0 540 6.60

540

-

-

... More
125mm Grade -B 540 720 5.60

180

-

-

... More
125mm Grade -A 720 990 5.60

270

-

-

... More
2nd Stage

-

-

-

... More
100mm Grade -A 0 180 4.80

180

-

-

... More
Laying, jointing, testing & commissioning at site in trenches following plain ended GMS pipes of heavy/medium grade as under conforming to IS/ ISO 1239 (part -I) 1990 or latest with upto date amendements capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipes ends shall be bevelled suitable for butt welding including the cost of jointing with butt welding conforming to IS 816-1969 or latest as applicable (leak proof) in three layers at site of work with welding rods of standard make and all allied accessories whatever required for welding at site, tail pieces, tees, bends manufactured from parent pipes as applicable to the particular reach & of approved specification as per site conditions and cutting of pipes etc. and cutting of pipes whatever required as per site requirement including carriage all lifts as directed by the Engineer incharge (Earth work shall be measured and paid for separately).

-

-

-

... More
Booster Stage

-

-

-

... More
Dia RD to RD wall thickness Grade

-

-

-

... More
125mm 0 330 4.80 GI (M)

330

-

-

... More
1st Stage

-

-

-

... More
125mm 990 1440 5.40 GI (H)

450

-

-

... More
125mm 1440 1720 4.80 GI (M)

280

-

-

... More
2nd Stage

-

-

-

... More
100mm 180 600 5.40 GI (H)

420

-

-

... More
100mm 600 975 4.50 GI (M)

375

-

-

... More
Providing welding and fixing M.S plate flanges of following dia (nominal bore) of following flanges Table conforming to IS 6392-1971 or latest with upto date amendments to MSERW/G.I. pipe after every 90 metres or as per site requirement including cutting of pipes wherever required welding in three layers (leak proof) conforming to specifications as prescribed in relevent IS code i.e IS 816-1969 or latest as applicable with upto date amendments with nuts, bolts & washers and specials etc. fonforming to IS 1963 or latest with upto date amendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticrossive paints complete in all respect in all leads lifts and carriage of material at site and as directed by the Engineer-in-charge.

-

-

-

... More
Booster Stage

-

-

-

... More
Dia RD to RD Length F.T.

-

-

-

... More
125mm 0 60 60 17

1

-

-

... More
125mm 60 330 270 5

3

-

-

... More
1st Stage

-

-

-

... More
125mm 0 540 540 34

6

-

-

... More
125mm 540 1170 630 28

7

-

-

... More
125mm 1170 1530 360 17

4

-

-

... More
125mm 1530 1720 190 5

2

-

-

... More
2nd Stage

-

-

-

... More
100mm 0 300 300 28

3

-

-

... More
100mm 300 720 420 17

5

-

-

... More
100mm 720 975 255 5

3

-

-

... More
Laying, jointing, testing and commissioning in trenches galvanised mild steel tube of following dia including providing and fixing tube fittings such as reducer increasers, sockets, union,tees,bends etc. where ever required (earth work in trenches to be measured and paid for separately) and as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts.

-

-

-

... More
DISTRIBUTION SYSTEM

-

-

-

... More
25 mm dia.(Light)

1150

-

-

... More
32 mm dia.(Light)

2000

-

-

... More
50 mm dia.(Light)

7200

-

-

... More
65 mm dia.(Light)

3700

-

-

... More
80 mm dia.(Light)

1500

-

-

... More
100 mm dia.(Light)

10500

-

-

... More
Cutting in earth work and disposal of excavated earth with in all leads and lifts of all kinds of soil and as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts as per the direction of Engineer-in-Charge.

535.29

-

-

... More
Excavation in foundation and trenches in all type of soil such as pickwork jumper work Kankar, moorum, shingles including decomposed soft and hard rock etcupto all heights stacking the excavated earth not more than 3mtrs clear from the edge of excavation and then returning the stacked soil in 15cm layers when required into plinths sides of foundations etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus excavated earth in all leads and lifts as per the direction of Engineer in-charge.

234.11

-

-

... More
Providing and laying cement concrete 1:4:8(1cement:4approved sand:8app.graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth and as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts.

45.32

-

-

... More
Providing and laying cement concrete 1:3:6(1cement:3approved sand:6app.graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth and as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts.

2.81

-

-

... More
Providing and laying cement concrete work 1:1:2 (1cement:1: sand: 2gradeds stone agg. 20mm nominal size & curing complete) excluding cost of form work and reinforcement for RCC work including all leads lifts complete and carriage of material etc. as per directions of Engineer incharge. in charge.

-

-

-

... More
in foundation, footings, base of columns and the like and mass concrete includiing all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.

5.62

-

-

... More
Wall (any thickness but not less than 0.1m thickness) attached pillasters,buttresses plinth and string courses etc. from top to foundation level upto floor two level and as per the direction of Engineer-in-charge.including entire carriage ofmaterial upto all leads and lifts.

19.48

-

-

... More
Providing and laying cement concrete 1:1.5:3(1cement:1.5approved sand:3approved graded stone aggregate 20mm nominal size)and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:-

-

-

-

... More
Foundation and plinth including entire carriage of material upto all leads and lifts.

46.85

-

-

... More
Wall (any thickness but not less than 0.1m thickness) attached pillasters,buttresses plinth and string courses etc. from top to foundation level upto floor two level and as per the direction of Engineer-in-charge.including entire carriage ofmaterial upto all leads and lifts.

160.91

-

-

... More
Providing and laying cement concrete 1:6:12 ( 1 cement : 6 sand :12 graded stone aggregate 40 mm nominal size ) and curring complete excluding cost of form work in foundation and plinth in all heights and depths including all leads lifts and carrige of material at site and as directed by the Engineer Incharge.

18.38

-

-

... More
Boulder filling under flooer hand packed tightly including all leads , lifts and carriage of material at site and as directed by the Enginner Incharge.

8.88

-

-

... More
Providing and laying reinforced cement concrete work 1:2:4 ( 1 cement :2 sand :4 graded stone aggregate 20 mm nominal size ) excluding cost of form work and reinforcement for reinforced concrete work:-

-

-

-

... More
in suspended floors, roofs, landings, shelves and their supports balconies beams, girders bressumers and cantilevers upto floor two level in all heights and depths includiing all leads lifts and carriage of material at site and as directed by the Engineer Incharge.

31.32

-

-

... More
In lintel, beams, girders, bressumeres and cantilever up to floor two level including all leads , lifts and carriage of material and as directed by the Engineer Incharge.

11.2

-

-

... More
Arch upto floor two level

12.94

-

-

... More
Providing & laying CC 1:2:4 1cement:2 sand 4 graded aggregates 20mm nominal size curing complete excluding cost of form work in foundation & plinth.

11.97

-

-

... More
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish. Including centring,shuttering strutting and propping etc. with wooden battens and ballies height of propping and centring below supporting floor to ceiling not exceeding 4mtrs and removal of the same for insitu reinforced concrete and plain concrete work in:-

-

-

-

... More
Vertical surface such as wall of (any thickness) partition and the like including attached pillaster buttresses plinth and string courses and like and as per the direction of Engineer-in-charge .including entire carriage of material upto all leads and lifts.

1837.06

-

-

... More
In lintel, beams, girders, bressumeres and cantilever up to floor two level including all leads , lifts and carriage of material and as directed by the Engineer Incharge.

45.74

-

-

... More
Flat surfaces such as soffits of suspended floors, roofs, landings and the like, floors etc., up to 200mm in thickness.

162.87

-

-

... More
Edge of slab and break in floor 20 cm wide

76.74

-

-

... More
Providing form work of ordinary timber planking so as to give a rough finish Including centring,shuttering strutting and propping etc. with wooden battens and ballies height of propping and centring below supporting floor to ceiling not exceeding 4mtrs and removal of the same for insitu reinforced concrete and plain concrete work:-

-

-

-

... More
in Arches beyond 6 mtr span including entire carriage of material upto all leads and lifts as per direction of Engineer-in-charge.

129.48

-

-

... More
Providing in RCC work smooth finishing of the exposed surface with cement mortar 1:3 ( 1 cement :3 sand ) .

952.94

-

-

... More
Providing tor steel reinforcement for RCC work including bending,binding and placing in position complete upto floor two level.as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts.

22084.81

-

-

... More
Providing and placing in horizontal layer filtering media duly graded, screened, washed and cleanned as specified by the Engineer incharge including all leads lifts and carriage of material at site and as directed by the Engineer incharge.

-

-

-

... More
Top layer :- fine sand ( Eff. Size of 0.20mmto 0.40 and uniformily coefficient 2.00 to 3.00)

19.37

-

-

... More
Second layer :- Course sand 3mm to 6mm

3.87

-

-

... More
Third layer :- Bajri 6mm to 20mm

1.29

-

-

... More
Forth layer :- Bajri 20mm to 25 mm

2.58

-

-

... More
Bottem layer Broken stone 50mm to 75mm

3.87

-

-

... More
Random rubble masonry/ polygonal rubble masonry ( uncoursed/ brought to courses) with hard of approved quality in foundation and plinth including levelling up with CC 1:6:12 (1cement:6sand:12 graded stone aggregate 20mm nominal size) at plinth level in:-cement mortar 1:6 (1 cement : 6 sand) including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.

36.86

-

-

... More
Laying and jointing in trenches galvanised mild steel steel tubes(light grade ) tube fittings( earth work in trenches to be measured and paid for separately) for scoure, inlet, outlet and over flow pipe with all leads and lifts.

-

-

-

... More
40mm dia

62.5

-

-

... More
50mm dia

25

-

-

... More
80mm dia

24

-

-

... More
Providing and fixing full way gun metal valve as per IS :780-1984 class-1 with hand wheel of following dia. including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.

-

-

-

... More
50mm dia.

4

-

-

... More
40mm dia.

11

-

-

... More
Providing and fixing double flanged cast iron sluice valve of following dia. of leader/Kirlosker/Bir/Kartar make as per IS 780 class PN-1.6 and capable of with standing the normal seat pressure as per IS 5312-1884 P-1 and as per direction of the Engineer- in-charge upto all lead and lifts.

-

-

-

... More
80mm dia

6

-

-

... More
Prov. & fixing SFRC Man hole cover with frame having frames size of 560 mm internal dia.should not be less than 58 kg including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.

3

-

-

... More
Prov. & fixing SFRC Man hole cover with frame having frames size of 600 mm internal dia.should not be less than 45 kg including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.

5

-

-

... More
Brick work using common burnt clay building bricks in super structure in Cement mortar 1:6 (1 cement : 6 sand) with in all leads , lifts and carriage of material at site and as directed by the Engineer Incharge. 2nd class bricks.

37.42

-

-

... More
Half brick work using common burnt clay building bricks in super structure in Cement mortar 1:4 (1 cement : 4sand) with in all leads , lifts and carriage of material at site and as directed by the Engineer Incharge. 2nd class bricks.

28.68

-

-

... More
Providing and fixing pressed steel door frames manufacuted from commercial M.S Seats of 1.25mm thickness including hinges jump lock jamb lead and it required angle threashald of MS angle 50x25mm or less tie of 1.25mm pressed MS welded or rigidly fixed together by mechanical means adjustable longs with split and tails to each jamb including steel butt hinges 2.5mm thick with guards, lock strick plate and shock as specified and applying a coat of steel primer after pretreatment of surface as directed by Engineer-in-Charge.

119.5

-

-

... More
Providing and fixing 1mm thick M.S.sheet garrage shutters with frame of 40mmx40mmx6mm angle iron 3.15mm M.S.gusset plates at junctions and corners all necessary fittings complete including applying a priming coat of red lead paint : Using M.S. angles 40mmx40mmx6mm for diagonal braces including entire carriage of material upto all leads and lifts.

24.76

-

-

... More
15 mm cement plaster in single coat on rough side of brick/concrete/ stone masonry wall for interior plastering upto floor two level including arrieses internal rounded angles chambers and rounded angles not exceeding 80 mm in grith and finished even and smooth in cement mortar 1:4 (1 cement : 4 sand) including all leads , lifts and carriage of material at site and as directed by the Enginner Incharge.

221.7

-

-

... More
20 mm cement plaster in single coat on rough side of brick/concrete/ stone masonry wall for interior plastering upto floor two level including arrieses internal rounded angles chambers and rounded angles not exceeding 80 mm in grith and finished even and smooth in cement mortar 1:6 (1 cement : 6 sand) including all leads , lifts and carriage of material at site and as directed by the Enginner Incharge.

264.9

-

-

... More
6mm thick cement plaster to ceiling in cement mortar 1:3 ( 1 cement : 3 sand) including all leads , lifts and carriage of material at site and as directed by the Enginner Incharge.

131.56

-

-

... More
White washing with lime on undecorated wall surfaces (Two coats) to give an even shade including throughly brooming the surface to remove all dirt dust and other foreign matter including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.

131.56

-

-

... More
Finishing Wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surfaces (two coat ) to give an even shade including throughly brushing the surface to remove all dirt and remains of loosepowderd material.

621.14

-

-

... More
Cement concrete flooring 1:2:4 ( 1cement : sand : 4 graded stone aggregate 20mm nominal size) and laid in one layer finished with a floating coat of neat cement, 40mm thick including all leads lifts and carriage of material at site as as per the direction of the Engineer incharge.

66

-

-

... More
Applying two coat of wood preservative on new wood based surface after and including preparing the surface by thoroughly cleaning dirt dust and other foreign matter.

10.66

-

-

... More
Applying a priming coat over new steel and steel based surface after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering and knotting, ready mixed paint brushing red lead , red oxide/ zink oxide chrome including all leads, lifts and carriage of material and as directed by the Engineer Incharge.

44.8

-

-

... More
Painting two coat (excluding priming coat) on new steel and steel based surfaces with ready mixed paint brushing to give an even shade including clearing of all dirt, dust and other foreign matter sand paper and stopping:- with ready mixed paint other than white, including all leads, lifts and carriage of materials and as directed by the Engineer Incharge.

44.8

-

-

... More
Providing and fixing MS grills of required pattern in wooden frames of windows etc with M.S flasts squar or rounded bars with rounded handed bolts and nuts or by screws plain grills. including all leads, lifts and carriage of material and as directed by the Engineer Incharge.

186.36

-

-

... More
Providing and fixing anodized aluminium sliding door bolts with nuts and serews complete as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts..:-250x16mm

4

-

-

... More
Providing and fixing anodized aluminium tower bolts (barrel type) with nuts and serews complete as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts:-

-

-

-

... More
200mmX10mm

8

-

-

... More
100mmx10mm

80

-

-

... More
Providing and fixing anodized aluminium handles with necessary screws complete as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts..:-

-

-

-

... More
125mm dia

12

-

-

... More
100mm dia

46

-

-

... More
Providing and fixing M.S.fan clamp(Type-I) of 16mm dial M.S. Bar bent to shape with hooked ends in RCC. Slab during laying including painting the exposed portion of loop all as per standard design complete.

4

-

-

... More
Providing and fixing 40x3mm flat iron hold fast 40cm long including fixing to frames 10cm diameter bolts and nuts and wooden plug and embedded in cement concrete block 30x30x15cm in C.C. 1:3:6 ( 1 cement : 3 sand : 6 graded stone aggragate 20mm niminal size) including all leads, lifts and carriage of material and as directed by the Engineer Incharge.

52

-

-

... More
Providing plinth protection 50mm thick in cement concrete 1:3:6 (1cement;3 sand:6 graded stone stone 20mm size) including all leads lifts and carriage of material at site and as directed by the Engineer Incharge.

42.46

-

-

... More
Providing under layer for plinth protection of 75mm thick uncolidated bed dry bricks/stone aggregate 40mm nomonal size with rammed consolidated and grouted with fine sand including preparing of ground in all leads and lifts and as directed by the Engineer Incharge.

42.46

-

-

... More
Steel work welded in built up sections, trusses, framed work, including cutting, hoisting, fixing in position and applying a priming coat of red lead paint in gratings, framed guard bars, ladders railling, brackets and similar works with all leads and lifts.

5.56

-

-

... More
Providing and Fixing Modular GI Box Paint Coated in Verious Size Including Complete in all respects.

-

-

-

... More
6 Module

20

-

-

... More
4 Module

10

-

-

... More
2 Module

10

-

-

... More
Providing and Fixing White Combination Modular Plates (Make Havells) Including Complete in all respects.

-

-

-

... More
6 Module

20

-

-

... More
4 Module

10

-

-

... More
2 Module

10

-

-

... More
Providing & fixing Light point, Fan point, Bulb point & Bell point in Modular Accessories including complete in all respects.

24

-

-

... More
Providing & fixing 6 amp set in Modular Accessories (Make Havells) including complete in all respects.

8

-

-

... More
Providing & fixing 16 amp set including Heavy duty 3 pin Socket in Modular Accessories (Make Havells) including complete in all respects.

8

-

-

... More
Providing & fixing Fan Regulator (1 M) in Modular Accessories (Make Havells) including complete in all respects.

6

-

-

... More
Providing & fixing Dummy Plate in Modular Accessories (Make Havells) including complete in all respects.

16

-

-

... More
Providing & fixing 32 amp DP switch with indicator in Modular Accessories (Make Havells) including complete in all respects.

10

-

-

... More
Providing & fixing 12 way Double Door Distribution Board (Make Havells) including complete in all respects.

4

-

-

... More
Providing & fixing 8 way Double Door Distribution Board (Make Havells) including complete in all respects.

4

-

-

... More
Providing & fixing MCB 10 amp to 32 amp (Make Havells) including complete in all respects.

24

-

-

... More
Providing & fixing MCB DP 40 amp to 63 amp (Make Havells) including complete in all respects.

8

-

-

... More
Providing & fixing Jambo Holder including complete in all respects.

12

-

-

... More
Providing & fixing LED Surface Square Panel Light 24 watt (make osram & Siska) including complete in all respects.

6

-

-

... More
Providing & fixing Pvc copper Single core cable wire 1.5mm (make Havells) including complete in all respects.

250

-

-

... More
Providing & fixing Pvc copper Single core cable wire 4mm (make Havells) including complete in all respects.

120

-

-

... More
Providing & fixing Pvc copper Single core cable wire 1Omm (make Havells) including complete in all respects.

60

-

-

... More
Providing & fixing 1200 mm Sweep Selling Fan (make Havells) including complete in all respects.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.