Himachal Pradesh Irrigation And Public Health Department Tender
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender
Civil And Construction
Irrigation Work
Eprocure
Opening Date19 Jan 2022
Closing Date27 Jan 2022
Tender AmountRefer Documents
Costs
EMD
₹ 1,43,300Document Cost
₹ 2,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_HPIPH_55890_1Bid Award Id
ViewTender No
JHT-BLP03-782Tender Authority
Himachal Pradesh Irrigation And Public Health Department ViewPurchaser Address
-Website
http://http://hpiph.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Booster Stage Phase 1st:-Booster stage Phase 1st:- GMS Pipe 150 mm dia ( medium class) of wall thickness 4.80 mm flange table 5 from RD 0/0 to 30
30
-
-
Ist Stage Phase 1st to old Bhallu: GMS Pipe 150 mm dia ( medium class) of wall thickness 4.80 mm flange table 5 from RD 0 to 275
275
-
-
1st Stage Phase 2nd to village Riyana: GMS Pipe 150 mm dia ( medium class) of wall thickness 4.80 mm flange table 17 from RD 0 to 90
90
-
-
GMS Pipe 150 mm dia ( medium class) of wall thickness 4.80 mm flange table 5 from RD 90 to 450
360
-
-
Providing, laying, jointing and testing in trenches of galvanised MSERW flanged pipe excluding cost of flanged bends of all degrees conforming to IS/:3183-2012 of followings grade as per dimensions, weight and test pressure mentioned there in code in random lengths of 4 to 6 mtrs the MS flanges are to be provided 5% of joints as per table given below confirming to IS 6392-1971 (latest upto date amendements) and remaining joints shall be butt welded joints by considering minimum three layers and welding of pipes will be as per IS:816-1969 with electrodes as per IS:814-1991 of make Adwani /Orelon (Adore) /ESAB. The welding of flnages to be done on both faces in two layers on outer face & one layer on inner face to make the joints leak proof and to the entire satisfaction of the Engineer-in-charge. The laying of pipe shall confirm to IS: 5822-1994 and as per CPHEEO manual. The laying will include all operations such as cutting welding and jointing including flushing cleaning and hydraulic testing complete in all respect to the entire satisfaction of the Engineer-in-charge including entire carriage of materials (earth work in trenches, flanged joint and butt welded joints except in bends to be measured and paid for separately) The pipes and specials shall have zinc coated ( out side & inside) as per BIS-4736, the galvanization shall be done by the manufacturing firm itself complete in all respect.
-
-
-
Booster Stage Phase 2nd & 3rd: 300 mm dia GMSERW pipe IS:3183-2012 grade L210 or A having wall thicthness 4.80 mm (RD 0/0 to 30 ) flange Table 5.
30
-
-
Ist Stage Phase 3rd to village Sangaswin & Kharotta: 250 mm dia GMSERW pipe IS:3183-2012 grade L210 or A having wall thicthness 5.20 mm (RD 0/0 to 90) flange Table 17.
90
-
-
250mm dia GMSERW pipe IS:3183-2012 grade L210 or A having wall thicthness 4.80 mm (RD 90 to 720) Flange Table 17.
630
-
-
250mm dia GMSERW pipe IS:3183-2012 grade L210 or A having wall thicthness 4.80 mm (RD 720 to 1725) Flange Table 5.
1005
-
-
Providing circumferencial Butt welded joints by electrical arc welding to various dias GI pipe medium / heavy class, welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS: 816-1969 specifications, by using welding electrodes of 2.50 mm to 6.30 mm of Advani , Oerlikon (Adore)-CITOJET/ESAB make conforming to IS:814-1991, at site of work complete in all respects, including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
-
-
-
150 mm dia
119
-
-
Providing circumferencial Butt welded joints by electrical arc welding to following diameter GMSERW pipe, welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS: 816-1969 specifications, by using welding electrodes of 2.50 mm to 6.30 mm of Advani , Oerlikon (Adore)-CITOJET/ESAB make conforming to IS:814-1991, at site of work complete in all respects, including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
-
-
-
250 mm dia
273
-
-
300 mm dia
4
-
-
Providing and welding M.S. flanges at suitable points to be provided 5% of total joint and remaining 95% joints with butt welded joint, conforming to following tables as per IS 6392-1971 (Latest with upto date amendments) with plain end GMS/GMSERW pipe in requsite ( minimum three) number of layers on both faces to make the joint leak proof. The welding of flanges should confirm to IS:816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1369-1967 including cost of gasket sheet, nuts & bolts. The thickness of gasket sheet not less then 3.00 mm confirming to IS 2712-1998. The work shall be done to the entire satifaction of engineer in charge with in all leads and lifts.
-
-
-
GMS Pipe 150 mm dia flange table 5 .
6
-
-
GMS Pipe 150 mm dia flange table 17 .
1
-
-
GMSERW Pipe 250 mm dia flange table 5.
8
-
-
GMSERW Pipe 250 mm dia flange table 17.
6
-
-
GMSERW Pipe 300 mm dia flange table 5.
1
-
-
Pumping MachineryBOOSTER STAGE Phase 1st to Village Bhallu Providing/Installation, erection, testing and commissioning of star rated energy efficient Mono Submersible pumping set of KSB/Calama/ Johnstion/ Crompton/BS/ SABAR/ Oswal/ Kirloskar make conforming to latest relevant BIS Code . The pump should be fitted with bronze impeller or suitable alloys suitable for handling Clear water having greased packed bearings and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) of required HP & 2900 RPM or as per manufacturer's specifications of reputed make confirming to BIS 9283-1979 latest with upto date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guards, erection clamps , cable clips, depth gauge NRV & Sluice valves of approved class etc. The work should be completed to the entire satisfaction of the Engineer-in – Charge. Discharge:- 10.39 LPS per set, Total dynamic head :- 32.32 metre, Residual head:- metres, Static head:- 30.00 metre, Dia of Rising Main:- 150 mm , Length of Rising Main:- 30 Rmt, Pumping Hours:- 20 hours, Coupling and base plate :- 2 sets, Turbidity :- less than 50 NTU, Temprature 20 degree to 45 degree centigrade.Limits of total head :- (-) 15% to (+) 10%
2
-
-
Providing and Installation of suitable star delta starter of MEI/Kilburn make starter confirming to BIS 8544 -1979 latest with upto date amendments for electric induction motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release with initial oil filing of suitable capacity.
1
-
-
Providing and fixing of M.S. sheet 16 SWG, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal electric duly painted. The drawing of panel board shall be subject to approval of Engineer in charge
1
-
-
Providing & fixing of 125 mm Square type auto electric AC supply Ammeter of AE /L&T/ Rishab make of suitable range with selector switches confirming to BIS 1248 - 1983 latest with up to date amendments.
1
-
-
Providing and fixing of 125 mm square type auto electric A.C. supply voltmeter of AE/L&T /Rishab make of 0-500 volts range with selector switches confirming to BIS: 4064-1978 with up to date amendments.
1
-
-
Providing fixing ICTP Main Switch with HRC fuses / side handled operated change over switch of L&T / crompton/ stanadards/ Havells make of suitable capacity operational rating as per IS 4064(part II) 1978 with up to date amendments)
1
-
-
Providing and fixing of Bus bar chamber having 3 core copper bars of suitable rating for full length of three phase and one bar of half the rating of full length for neutral confirming to BIS 8064-1976 and 11353-1985 read with 5578-1985- latest with up to date ammendments .
1
-
-
Providing and fixing of MCB of havells/MDS/ Kilburn/ Jyoti make of suitable capacity on incoming feeder with initial oil filling as per IS: 2516-1985 latest with up to date amendments with neutral linked under voltage release.
1
-
-
Providing and fixing Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I&II) with up to date amendments of 15 watts.
1
-
-
Providing and fixing 50 mm dial hour run metre of CEE/NEE make of suitable range as per relevant BIS specifications.
1
-
-
Providing and fixing double flanged Cast iron sluice valve of Leader/Kirloskar make class PN 1.0 of 100 mm dia capable of withstanding the normal seat pressure of 10.20 Kg/cm2 as per IS: 780-1984 with up to date amendments complete in all respects.
1
-
-
Providing and fixing double flanged Cast Iron (Swing check type) reflux valve Leader/Kirloskar make 125 mm dia class PN 1.0 capable of withstanding the normal seat pressure 10.20 kg/cm2 as per BS: 5312-1984 with up to date amendments .
1
-
-
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable ( one cable carrying all the three phases) of size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. Motor side: Suitable size. Supply side: Suitable size
1
-
-
Providing and fixing of PVC joint less flat water proof cable as per BIS 694-1990 latest with up to date amendments suitable for the pump sets offered from MCB to motor including all other electrical equipments/ accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities same shall be replaced by the bidder.
1
-
-
Providing and fixing double loop earthing with copper strips & copper plate 600 x600x3 mm thick complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx3mm copper strips, digging of pits & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
1
-
-
Providing and fixing circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0- 16 Kg/cm2
2
-
-
Providing and laying delivery pipe 150mm dia. and common header 150mm dia GMS Tubes (Medium Class) (IS:1239 - 1979) jointed with MS flanges of table-17 as per IS: 6392-1971 (upto a length of 20 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses as per layout drawings approved by Engineer-in-Charge.
1
-
-
Providing of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments Bajaj/L&T/Asian/cromption make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to BIS –4064-1978 or latest with HRC fuses (range to be specified by the tendrerer).
2
-
-
1st STAGE Phase 1st to village old Bhallu
-
-
-
Providing & Installation of horiontal spindle horizontal split casing / end suctions (back pull out arrangement ) single /double/multistage centrifugal pump or combination of pump in series of Mather and Platt / KSB/Kirloskar / Crompton / BS make as per BIS 1520-1980 with up to date amendments, read with IS:9137-1978 or latest edition suitable for lifting clear water . The pump should be fitted with bronze impellers of suitable alloys, priming funnels , casing rings, shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on MS/ Cast steel base plate ( base plate to be provided from the manufacturer,s of the pumping unit only) to slippering type drip proof induction motor of standard make such as Kirloskar/Crompton/ BHEL confirming to BIS 9238-1979 latest with up to date amendments and suitable for operation on 400 (+/-) 10% volts, 50 cycles / second, three phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of + 10% and - 15% of the duty point head. The motor should be as per IS 325-1978 with up to date amendments.The pump set should suitable for operation on data given below:- Discharge:- 10.39 LPS per set, Total dynamic head :-51.71 metre, LWL in sump well :- 490.30 metre, Shaft level:- 490.80 metre , Level at discharge point :- 533 metre , Residual head:- 3 metres, Static head:- 42.70 metre , Dia of Rising Main:- 150 mm , Length of Rising Main:- 275 Rmt, Pumping Hours:- 20 hours, Coupling and base plate :- 2 sets, Turbidity :- less than 50 NTU, Temprature 20 degree to 45 degree centigrade.
2
-
-
Providing, fixing testing and successfully comissioning of floor mounted soft starter suitable for the pumping machinery of Crompoton Greaves / Siemens / L& T / ABB/ Allen Bradley duly certified by CE/UL/CSA suitable for motor operating in 200-480 VAC 3 phase Ambient temperature 25 degree to 60 degree cel. Ramp up time 0-20 second . inbuilt by pass system duly certified by CE/UL/CSA fully programmable including panel board with accessories and MCCB of reputed make with Ammeter,Voltmeter meter push button and single phase preventor complete. All digital display connected with motor etc. and all other connections needed to make the motor pump run successfully all as per the direction of Engineer in charge complete in all respects. The equipment supplied should be compatible / upgradable for use in future automization of the scheme with below mentioned technical specifications of soft panel / soft starter providing and fixing in position at site these accessories complete in all respect in all leads and lifts and carriage of material.
2
-
-
Providing fixing ICTP Main Switch with HRC fuses / side handled operated change over switch of L&T / crompton/ stanadards/ Havells make of suitable capacity operational rating as per IS 4064(part II) 1978 with up to date amendments)
2
-
-
Providing and fixing double flanged Cast iron sluice valve of Leader/Kirloskar make class PN 1.00 of 250 mm dia for the suction pipe capable of withstanding the normal seat pressure of 10.20 Kg/cm2 as per IS: 780-1984 with up to date amendments complete in all respects.
2
-
-
Providing and fixing double flanged Cast Iron sluice valve Leader/Kirloskar make one dia higher than pump for the delivery line of the pump of class PN 1.0 capable of withstanding the normal seat pressure 10. 20 kg/cm2 as per IS: 780-1984 with up to date amendments complete in all respects.
2
-
-
Providing and fixing double (swing type) flanged Cast Iron reflux valve of Leader/Kirloskar make one dia higher than pump having bye pass arrangement on the delivery line of the pump of class PN 1.0 and capable of withstanding the normal seat pressure of 10.20 Kg/cm2 as per IS: 780-1984 with up to date amendments complete in all respects.
2
-
-
Providing and fixing double flanged Cast Iron Non Return valve of Leader/Kirloskar make of class PN 1.0 one dia higher than pump having bye pass arrangment on the delivery line of pump and capable of withstanding the normal seat pressure of 10.20 Kg/cm2 as per IS: 780-1984 with up to date amendments complete in all respects.
1
-
-
Providing and fixing 125 mm dia circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0- 52 Kg/cm2
2
-
-
Providing and fixing double flanged GMS piping network for suction and delivery pipes suitable to pumps offered and common header as per the rising main respectively complete with all specials such as rappers, flanges, rubber gaskets minimum 3 mm in thickness as per IS 2712-1979, nuts and bolts as per IS:1364-1983, bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as per drawing up to 5 metre away from the outer wall of pump houses. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated.The size of various components are as under:- Suction pipe 100 mm dia Minimum length= 5 metre Delivery pipe 100 mm dia Minimum length= 10 metre Common header 100 mm dia Minimum length = 10 metre
1
-
-
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. Motor side: Suitable size min length = 20 mtrs. Supply side: Suitable size min length = 10 mtrs.
1
-
-
Providing and fixing double loop earthing with copper strips & copper plate 600 x600x3 mm thick complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx3mm copper strips, digging of pits & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
1
-
-
BOOSTER STAGE PHASE II & III Providing/Installation, erection, testing and commissioning of star rated energy efficient Mono Submersible pumping set of KSB/Calama/ Johnstion/ Crompton/BS/ SABAR/ Oswal/ Kirloskar make conforming to latest relevant BIS Code . The pump should be fitted with bronze impeller or suitable alloys suitable for handling Clear water having greased packed bearings and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) of required HP & 2900 RPM or as per manufacturer's specifications of reputed make confirming to BIS 9283-1979 latest with upto date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guards, erection clamps , cable clips, depth gauge NRV & Sluice valves of approved class etc. The work should be completed to the entire satisfaction of the Engineer-in – Charge.
2
-
-
Discharge:- 31.85 LPS per set, Total dynamic head :- 33.48 metre, Residual head:- 3metres, Static head:- 30.00 metre, Dia of Rising Main:- 300 mm , Length of Rising Main:- 30 Rmt, Pumping Hours:- 16 hours, Coupling and base plate :- 2 sets, Turbidity :- less than 50 NTU, Temprature 20 degree to 45 degree centigrade.Limits of total head :- (-) 15% to (+) 10%
-
-
-
Providing and Installation of suitable star delta starter of MEI/Kilburn make starter confirming to BIS 8544 -1979 latest with upto date amendments for electric induction motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release with initial oil filing of suitable capacity.
1
-
-
Providing and fixing of M.S. sheet 16 SWG, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal electric duly painted. The drawing of panel board shall be subject to approval of Engineer in charge
1
-
-
Providing & fixing of 125 mm Square type auto electric AC supply Ammeter of AE /L&T/ Rishab make of suitable range with selector switches confirming to BIS 1248 - 1983 latest with up to date amendments.
1
-
-
Providing and fixing of 125 mm square type auto electric A.C. supply voltmeter of AE/L&T /Rishab make of 0-500 volts range with selector switches confirming to BIS: 4064-1978 with up to date amendments.
1
-
-
Providing fixing ICTP Main Switch with HRC fuses / side handled operated change over switch of L&T / crompton/ stanadards/ Havells make of suitable capacity operational rating as per IS 4064(part II) 1978 with up to date amendments)
1
-
-
Providing and fixing of Bus bar chamber having 3 core copper bars of suitable rating for full length of three phase and one bar of half the rating of full length for neutral confirming to BIS 8064-1976 and 11353-1985 read with 5578-1985- latest with up to date ammendments .
1
-
-
Providing and fixing of MCB of havells/MDS/ Kilburn/ Jyoti make of suitable capacity on incoming feeder with initial oil filling as per IS: 2516-1985 latest with up to date amendments with neutral linked under voltage release.
1
-
-
Providing and fixing Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I&II) with up to date amendments of 15 watts.
1
-
-
Providing and fixing 50 mm dial hour run metre of CEE/NEE make of suitable range as per relevant BIS specifications.
1
-
-
Providing and fixing double flanged Cast iron sluice valve of Leader/Kirloskar make class PN 1.0 of 300 mm dia capable of withstanding the normal seat pressure of 10.20 Kg/cm2 as per IS: 780-1984 with up to date amendments complete in all respects.
1
-
-
Providing and fixing double flanged Cast Iron reflux valve Leader/Kirloskar make 300 mm dia class PN 1.0 capable of withstanding the normal seat pressure 10.20 kg/cm2 as per BS: 5312-1984 with up to date amendments .
1
-
-
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable ( one cable carrying all the three phases) of size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. Motor side: Suitable size. Supply side: Suitable size
1
-
-
Providing and fixing of PVC joint less flat water proof cable as per BIS 694-1990 latest with up to date amendments suitable for the pump sets offered from MCB to motor including all other electrical equipments/ accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities same shall be replaced by the bidder.
1
-
-
Providing and fixing double loop earthing with copper strips & copper plate 600 x600x3 mm thick complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx3mm copper strips, digging of pits & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
1
-
-
Providing and fixing circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0- 16 Kg/cm2
2
-
-
Providing and laying delivery pipe 250mm dia. and common header 250 mm dia GMSERW pipe (Medium Class) (IS:3183-2012 ) jointed with MS flanges of table-17 as per IS: 6392-1971 (upto a length of 20 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses as per layout drawings approved by Engineer-in-Charge.
1
-
-
Providing of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments Bajaj/L&T/Asian/cromption make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to BIS –4064-1978 or latest with HRC fuses (range to be specified by the tendrerer).
2
-
-
1st STAGE Phase 1st to Village Riyana Providing & Installation of horiontal spindle horizontal split casing / end suctions (back pull out arrangement ) single /double/multistage centrifugal pump or combination of pump in series of Mather and Platt / KSB/Kirloskar / Crompton / BS make as per BIS 1520-1980 with up to date amendments, read with IS:9137-1978 or latest edition suitable for lifting clear water . The pump should be fitted with bronze impellers of suitable alloys, priming funnels , casing rings, shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on MS/ Cast steel base plate ( base plate to be provided from the manufacturer,s of the pumping unit only) to slippering type drip proof induction motor of standard make such as Kirloskar/Crompton/ BHEL confirming to BIS 9238-1979 latest with up to date amendments and suitable for operation on 400 (+/-) 10% volts, 50 cycles / second, three phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of + 10% and - 15% of the duty point head. The motor should be as per IS 325-1978 with up to date amendments.The pump set should suitable for operation on data given below:-
2
-
-
Discharge:- 10.00 LPS per set, Total dynamic head :-81.76 metre, LWL in sump well :- 490.30 metre, Shaft level:- 490.80 metre , Level at discharge point :- 560.50 metre , Residual head:- 3 metres, Static head:- 70.20 metre , Dia of Rising Main:- 150 mm , Length of Rising Main:- 450 Rmt, Pumping Hours:- 20 hours, Coupling and base plate :- 2 sets, Turbidity :- less than 50 NTU, Temprature 20 degree to 42 degree centigrade.
-
-
-
Providing, fixing testing and successfully comissioning of floor mounted soft starter suitable for the pumping machinery of Crompoton Greaves / Siemens / L& T / ABB/ Allen Bradley duly certified by CE/UL/CSA suitable for motor operating in 200-480 VAC 3 phase Ambient temperature 25 degree to 60 degree cel. Ramp up time 0-20 second . inbuilt by pass system duly certified by CE/UL/CSA fully programmable including panel board with accessories and MCCB of reputed make with Ammeter,Voltmeter meter push button and single phase preventor complete. All digital display connected with motor etc. and all other connections needed to make the motor pump run successfully all as per the direction of Engineer in charge complete in all respects. The equipment supplied should be compatible / upgradable for use in future automization of the scheme with below mentioned technical specifications of soft panel / soft starter providing and fixing in position at site these accessories complete in all respect in all leads and lifts and carriage of material.
2
-
-
Providing fixing ICTP Main Switch with HRC fuses / side handled operated change over switch of L&T / crompton/ stanadards/ Havells make of suitable capacity operational rating as per IS 4064(part II) 1978 with up to date amendments)
2
-
-
Providing and fixing double flanged Cast iron sluice valve of Leader/Kirloskar make class PN 1.0 of 250 mm dia for the suction pipe capable of withstanding the normal seat pressure of 10.20Kg/cm2 as per IS: 780-1984 with up to date amendments complete in all respects.
2
-
-
Providing and fixing double flanged Cast Iron sluice valve Leader/Kirloskar make and one dia higher than pump having bye pass arragment on the delivery line of pump, Class PN 1.0 capable of withstanding the normal seat pressure of 10.20Kg/cm2 as per IS: 780-1984 with up to date amendments complete in all respects.
2
-
-
Providing and fixing double flanged Cast Iron Non Return valve of Leader/Kirloskar make of class PN 1.6 one dia higher than pump having bye pass arrangment on the delivery line of pump and capable of withstanding the normal seat pressure 16.32 Kg/cm2 as per BIS-5312-1984 with up to date amendments complete in all respects.
2
-
-
Providing and fixing double flanged Cast Iron reflux valve of Leader/Kirloskar make 200 mm dia having bye pass arrangement on the delivery line of the pump of class PN 1.0 and capable of withstanding the normal seat pressure 10.20 Kg/cm2 as per BIS-5312-1984 with up to date amendments complete in all respects.
1
-
-
Providing and fixing 125 mm dia circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0- 52 Kg/cm2
2
-
-
Providing and fixing double flanged GMS piping network for suction and delivery pipes suitable to pumps offered and common header as per the rising main respectively complete with all specials such as rappers, flanges, rubber gaskets minimum 3 mm in thickness as per IS 2712-1979, nuts and bolts as per IS:1364-1983, bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as per drawing up to 5 metre away from the outer wall of pump houses. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated.The size of various components are as under:- Suction pipe 100 mm dia Minimum length= 5 metre Delivery pipe 100 mm dia Minimum length= 10 metre Common header 100 mm dia Minimum length = 10 metre and will extend up to 5 meters from the outer wall of the pump house in the directed to be jointed.
1
-
-
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. Motor side: Suitable size min length = 20 mtrs. Supply side: Suitable size min length = 10 mtrs.
1
-
-
Providing and fixing double loop earthing with copper strips & copper plate 600 x600x3 mm thick complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx3mm copper strips, digging of pits & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
1
-
-
1st STAGE Phase 3rd to Village Sangaswin & Kharotta Providing & Installation of horiontal spindle horizontal split casing / end suctions (back pull out arrangement ) single /double/multistage centrifugal pump or combination of pump in series of Mather and Platt / KSB/Kirloskar / Crompton / BS make as per BIS 1520-1980 with up to date amendments, read with IS:9137-1978 or latest edition suitable for lifting clear water . The pump should be fitted with bronze impellers of suitable alloys, priming funnels , casing rings, shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on MS/ Cast steel base plate ( base plate to be provided from the manufacturer,s of the pumping unit only) to slippering type drip proof induction motor of standard make such as Kirloskar/Crompton/ BHEL confirming to BIS 9238-1979 latest with up to date amendments and suitable for operation on 400 (+/-) 10% volts, 50 cycles / second, three phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of + 10% and - 15% of the duty point head. The motor should be as per IS 325-1978 with up to date amendments.The pump set should suitable for operation on data given below:-
2
-
-
Discharge:- 21.86LPS per set, Total dynamic head :-148.29 metre, LWL in sump well :- 490.30 metre, Shaft level:- 490.80 metre , Level at discharge point :- 624.90 metre , Residual head:- 3 metres, Static head:- 134.60 metre , Dia of Rising Main:- 250 mm , Length of Rising Main:- 1725 Rmt, Pumping Hours:- 20 hours, Coupling and base plate :- 2 sets, Turbidity :- less than 50 NTU, Temprature 20 degree to 42 degree centigrade.
-
-
-
Providing, fixing testing and successfully comissioning of floor mounted soft starter suitable for the pumping machinery of Crompoton Greaves / Siemens / L& T / ABB/ Allen Bradley duly certified by CE/UL/CSA suitable for motor operating in 200-480 VAC 3 phase Ambient temperature 25 degree to 60 degree cel. Ramp up time 0-20 second . inbuilt by pass system duly certified by CE/UL/CSA fully programmable including panel board with accessories and MCCB of reputed make with Ammeter,Voltmeter meter push button and single phase preventor complete. All digital display connected with motor etc. and all other connections needed to make the motor pump run successfully all as per the direction of Engineer in charge complete in all respects. The equipment supplied should be compatible / upgradable for use in future automization of the scheme with below mentioned technical specifications of soft panel / soft starter providing and fixing in position at site these accessories complete in all respect in all leads and lifts and carriage of material.
2
-
-
Providing fixing ICTP Main Switch with HRC fuses / side handled operated change over switch of L&T / crompton/ stanadards/ Havells make of suitable capacity operational rating as per IS 4064(part II) 1978 with up to date amendments)
2
-
-
Providing and fixing double flanged Cast Steel sluice valve of Leader/Kirloskar make class ASA-150 of 250 mm dia for the suction pipe capable of withstanding the normal seat pressure 26 kg/cm2 as per BS: 1414/ API 600 with up to date amendments .
2
-
-
Providing and fixing double flanged Cast Steel sluice valve Leader/Kirloskar/KSB make one dia higher than pump for the delivery line of the pump of class ASA-150 capable of withstanding the normal seat pressure 26 kg/cm2 as per BS: 1414/ API 600 with up to date amendments .
2
-
-
Providing and fixing double flanged Cast Steel Non Return valve of Leader/Kirloskar/KSB make of class ASA-150 of one dia higher than pump having bye pass arrangment on the delivery line of pump and capable of withstanding the normal seat pressure 26 Kg/cm2 as per BS:1868/ API 600 with up to date amendments complete in all respects. ( Total head i/c water hammer effect= metre).
2
-
-
Providing and fixing double flanged Cast Steel reflux valve of Leader/Kirloskar/KSB make 200 mm dia having bye pass arrangement for rising main of class ASA-150 and capable of withstanding the normal seat pressure 26 kg/cm2 as per BS: 1868/API 600 with up to date amendments.( Total head i/c water hammer effect= metre).
1
-
-
Providing and fixing 125 mm dia circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0- 52 Kg/cm2
2
-
-
Providing and fixing double flanged GMS piping network for suction and delivery pipes suitable to pumps offered and common header as per the rising main respectively complete with all specials such as rappers, flanges, rubber gaskets minimum 3 mm in thickness as per IS 2712-1979, nuts and bolts as per IS:1364-1983, bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as per drawing up to 5 metre away from the outer wall of pump houses. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated.The size of various components are as under:- Suction pipe 200 mm dia Minimum length= 5 metre Delivery pipe 150 mm dia Minimum length= 10 metre Common header 150 mm dia Minimum length = 10 metre
1
-
-
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. Motor side: Suitable size min length = 20 mtrs. Supply side: Suitable size min length = 10 mtrs.
1
-
-
Providing and fixing double loop earthing with copper strips & copper plate 600 x600x3 mm thick complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx3mm copper strips, digging of pits & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
1
-
-
Evaluation Notes How It Works ?
Potential Partner