Himachal Pradesh Irrigation And Public Health Department Tender
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender
Civil And Construction
Pipe Line Project
Eprocure
Opening Date17 Feb 2024
Closing Date23 Feb 2024
Tender Amount₹ 37,04,843
Costs
EMD
₹ 63,500Document Cost
₹ 400Tender Fee
Refer Documents
Summary
Providing Fhtc By Improvement Of Lwss To Mehal Preet Nagar Under Jjm In Gp Tikkri Kathad, Tehsil Pachhad Distt. Sirmour
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HPIPH_86301_1Bid Award Id
ViewTender No
9975-10074 dated 09-02-2024Tender Authority
Himachal Pradesh Irrigation And Public Health Department ViewPurchaser Address
-Website
http://http://hpiph.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
First Stage
-
-
-
1 0-200 65mm 4.80 mm 200 Grade-A
200
-
-
2 200-1800 65mm 4.40 mm 1600 Grade-A
1600
-
-
Second Stage
-
-
-
1 0-200 65mm 4.40 mm 200 Grade-A
200
-
-
Laying, jointing, testing & commissioning at site in trenches following plain ended GMS of Heavy Grade as under confirming to BIS 1239 (Part-1) 1990 & specifications latest with upto date amendments of capable of withstanding required test pressure as prescribed in BIS code in random lengths of 5.5 to 6.50 mtr. The pipes ends shall be bevelled suitable for butt weld including the cost of jointing with butt welding conforming to IS 816-1969 or latest as applicable (leak proof) in three layers at site of work with welding rods of standard make and all allied accessories whatever required for welding at site, tail pieces, tees, bends manufactured from parent pipes etc. and cutting of pipes wherever required as per site requirement including carriage in all leads and lifts and as directed by Engineer-in-charge.
-
-
-
First Stage
-
-
-
Sr. No RD Dia Thickness Length in Rmt
-
-
-
1 1800-2260 65mm(H) 4.50mm 460
460
-
-
Second Stage
-
-
-
1 200-485 65mm (H) 4.50mm 285
285
-
-
Providing, welding and fixing M.S. plate flanges of following dia. (nominal bore) of following Flange Tables confirming to IS 6392-1971 or latest with up to date ammendments to G.I pipe after every 90 meter or as per requiement including cutting of pipes wherever required, welding in three layers (leak proof) confirming to specifications as prescribed in relvent I.S. Code i.e. IS 816-1969 or latest as applicable with up to date ammendments with nuts, bolts & washers & specials etc. confirming to IS-1963 or latest with up to date ammendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticorosive paints complete in all respect including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
-
-
-
First Stage
-
-
-
Sr. No Nominal Dia RD Length in Rmt Flange table
-
-
-
1 65mm 0-400 400 34
4
-
-
2 65mm 400-1300 900 28
10
-
-
3 65mm 1300-1800 500 17
6
-
-
4 65mm 1800-2260 460 5
5
-
-
Second Stage
-
-
-
1 65mm 0-100 100 28
1
-
-
2 65mm 100-400 300 17
3
-
-
3 65mm 400-485 85 5
1
-
-
(Centrifugal Pumping Machinery)
-
-
-
First Stage
-
-
-
Prov. fixing commissioning & testing of horizontal spindle ,horizontal/redial split casing/end section ( back full out arrangement )single/double/multistage centrifugal pump or reciprocating pumps ,in series /parallel of recommended make such as Matter Platt/KSB/Beacon weir/Joyti /WASP/ASPEE (Asea Brown Boven Ltd.)as per BIS 1520-1980with up to date amendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze ,impeller, funnels ,casing ring and shaft sleeves of bronze shaft of steel grade with cast iron casing coupled directly through a flexible coupling on a common CI/Cast steel/base plate (base plate to be from the manufacture of the pumping unit only) to be coupled with motor including carriage of pump by mechanical transport & head load i/c testing complete at site , (NOTE- Tender to be called for per set not for per HP rate.)
2
-
-
Total Head 498.5mtrs
-
-
-
Capacity 3.76 lps
-
-
-
Dia of R/Main 65 mm
-
-
-
Length of R/main 2260 mtrs
-
-
-
SITE CONDITIONS:-
-
-
-
Location of Site:- TO be filled by Engineer-in-Charge
-
-
-
The altitude of place in which the motor is intended to work in ordinary service (in metres) :- To be filled in by Engineer-Incharge
-
-
-
Humidity:- Weather remains humid during monsoon season.
-
-
-
Nature of atmosphere:- As normally encounterd in Shivalik Range
-
-
-
Detail of quality of water:- Clear cold water
-
-
-
Water free from sand or not :- Yes
-
-
-
Water corosive or not :- Not
-
-
-
Turbidity (if any):- Upto 50 PPM
-
-
-
NPSH available:- positive suction
-
-
-
Any other information or requirement:-
-
-
-
OPERATING CONDITIONS:-
-
-
-
Type of current:- AC three/single phase
-
-
-
Operating frequency:- 50 HZ
-
-
-
Rated voltage:- 400 (+/-) 10% volts
-
-
-
System of earthing if any to to be adopted.:- Double loop earthing as per BIS 3043-1987 latest with upto date ammendments.
-
-
-
No. of working hours per day:- 8 hours
-
-
-
Speed of revolution in RPM:- To be quoted by tenderer
-
-
-
Direction of rotation:- To be quoted by tenderer
-
-
-
The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service. 35 Degree Centigrade
-
-
-
MOTOR:- BIS 325-1978 read with BIS 900-1992 (latest)with upto date ammendments.
-
-
-
Ref. to BIS code:-
-
-
-
Type of enclosure of motor:- SPDP(as per BIS 4691-1985 (latest)
-
-
-
Type of duty:- Continuous as per IS-12824-1989 or latest with up to date ammendments.
-
-
-
Mechanical out put in KW:- Suitable for driving centrifugal pumps required for duties specified against pumps.To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover.
-
-
-
Class of insulation:- Class ~B~
-
-
-
Particulars of test reqd. & where they are to be conducted:- As per terms & conditions
-
-
-
Particulars as to whether voltage limiting device will be employed:- ATS/star delta starter,oil immersed,fully automatic to be installed between bus bar & motor Shunt capacitor is also proposed to be installed for improving the power factor at site.
-
-
-
(NOTE:- Star delta starter upto 37.5 KW, ATS between 37.5 KW to 50 KW & Stator rotor starter with slip ring motor beyond 50 KW)
-
-
-
Motor whether squirrel cage or slipring:- Squirrel cage/slip-ring
-
-
-
(Note:- Squirrel cage upto 40HP and slipring above 40HP)
-
-
-
Details of shaft extension reqd.:- Just sufficient to provide direct drive by flexible coupling to pump.
-
-
-
Type of slip-ring gear whether continouly rated or for starting purposes only & whether to be fitted with brush lifting or short circuit arrangements or both if interlocks are rquired:- Continouslly rated for Squirrel cage/ Slipring motor
-
-
-
Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit.:- Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.
-
-
-
Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelerated & No.of starts during a specified period.:- Sufficient to work the pump offered.
-
-
-
Where possible fault capacity of the system to which the motor is connected.:- The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations.
-
-
-
PUMP : BIS 1520-1980 read with BIS 9137-1978 both with up to date ammendments.
-
-
-
Nos of pumps reqd.:- 2 nos. pumps one pump will run and one will acts as standby
-
-
-
Spare parts required:- For two years normal maintenance as recommended by manufacturer.
-
-
-
Optional fittings reqd.:- Air cock for exahausting air from each stage.
-
-
-
PUMP OPERATING CONDITIONS:-
-
-
-
Capacity (in LPS) 3.76 LPS
-
-
-
Total head (in Mts).:- 498.5 Mtrs
-
-
-
If total head is not known then
-
-
-
following details be provided:-
-
-
-
i) Static head ( in mtrs) 389.00 Mtrs
-
-
-
ii) Minimum depth of water( in mtrs)
-
-
-
iii) Variation in water level ( in mtrs)
-
-
-
iv) Ground level to max. water level ( in mtrs)
-
-
-
v) Ground level to delivery point ( in mtrs)
-
-
-
vi) Pressure in the suction tank (in Kg/cm^2 )
-
-
-
vii) Pressure in the delivery tank (in Kg/cm^2 )
-
-
-
Length of R/Main (in metres):- 2260 Mtrs
-
-
-
Dia of R/Main (in mm):- 65 mm dia
-
-
-
Drive arrangement:- Direct through flexible coupling on a common base plate.
-
-
-
Drive type:- Electric driven
-
-
-
NPSH reqd.:- To be quoted by the tenderer
-
-
-
Limits of total head in which the pump is reqd. to operate.:- (-) 15% to (+) 10% of total head.
-
-
-
Suction/delivery size of pump:- To be specified by the tenderer
-
-
-
Efficiency of pump at:- To be specified by the tenderer
-
-
-
a) duty head
-
-
-
b) (+)10 % head
-
-
-
c) (-) 15 % head
-
-
-
Material of construction:- To be specified by the tenderer (manufacturer's certficate to be appended)
-
-
-
Providing and fixing of auto control panel with push button 2 No star delta starter centrifugal pumps of L&T and reputed make fabricated with M.S. sheet and angle stand duly painted and complete with internal wiring, comprising of main switch of suitable Amp., T.P. volte meter, copor busbar, ammeter, hour run metre, phase indicating lamps with GMS based, remote start/stop operation call/SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hour in a day, imbuilt protection against overload/ undervoltage, dry run, single phase preventer, inbuilt GPS tracker, phase reversal configurable volt/current limits with a facility to access the systemthrough minimum 10 No. authenticate mobile Nos. complete in all respect, including intire carriage of materials all leads and lifts, installation and testing at site with entire saisfaction of engineer-in-incharge. (All meters to be installed shall be digital)
-
-
-
Supply and fixing at site of Kirloskar/Kilbum/IVC/Foress/Gled/BHEL/Leader/KSB make of Cast steel doubled flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 5(a)+surge pressure & confirming to API-standdards with up to date ammendments for delivery line of pump. Class of valve shall be ASA-600
-
-
-
Supply and fixing at site of Kirloskar/Kilbum/IVC/Foress/Gled/BHEL/Leader/KSB make of Cast steel doubled flanged swing check type reflux valve delivery line of pump having bye pass arrangement & size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 5(a)+surge pressure. The size of of refluxe & confirming to API-standdards with up to date ammendments for delivery line of pump. Class of valve shall be ASA-600
-
-
-
Supply and fixing at site of Kirloskar/Kilbum/IVC/Foress/Gled/BHEL/Leader/KSB make of Cast steel doubled flanged swing check type reflux valve confirming to API standard with up to date ammendments for R/Main as mentioned in item No. 5 (c) for withstanding nominal seat pressure as mentionmed in item No. 5(a)+surge pressure The size of refluxe valve shall be equal to size of Rising Main and the same shall be provided with suitable confirming to API-standdards with up to date ammendments for delivery line of pump. Class of valve shall be ASA-600
-
-
-
Supply and fixing at site leader/KSB/Kirlosker/ make cast iron double flanged sluice valve (In case suction +ve) for suction pipe having size one or two size larger than suction size of pump such that velocity of flow in suction pipe is not more than 3.00 mtr/sec. and conforming to BIS standards with up to date arrangement. class of valve shall be PN 1.60.
-
-
-
P/L & fixing suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC known as GEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authoritie. In case of non acceptance by HPSEB authorities shall have to be replaced by the tenderer free of cost.
-
-
-
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
-
-
-
P/L double loop earthing with G.I. pipes, strips and G.I. plates 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
-
-
-
Supply and fixing errection of floor/wall mounted power factor shunt capacitor confirming to BIS 2834-1986 or latest with upto date ammedments of BHEL/GEC/Machneil/Mager/Bajaj/L&T make to raise the prevailling power factor at site to 0.95 for direct connection to iinduction motor individual of requirement KVAR according to HP of motor offered including cable Siemens/gloster/ICC make from busbar chamber to capcitor & also including L&T/Kirlburn/Standard/Seimen/Havells make ICTP switches confirming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tendrer)
-
-
-
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc.conforming to BIS 3624-1987 or latest with up to date ammendments.
-
-
-
P/F double flanged suction, delivery pipe & common header of MSERW pipe grade -A considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 5 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump. The thickness of MSERW pipe 65 mm dia and shall be 4.80 mm with flanged joints of Flange table FT-34.
-
-
-
2nd stage:-
-
-
-
Supply, erection, testing & commissioning of submersible pumping set of reputed make such as KSB/BS/ Johnston/Kirloshker/Worthington/Oswal/Sabar Brand conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having characterstics as mentioned in item 5(A) greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton/Havels make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guard, errection clamps, tubelar pipe fitted with outlet of tank with suitable arrangement welding/ connecting to GI pipe (GI pipe /tubelar pipe for pump will be issued by the department free of cost), cable clips. & depth gauge etc. & suitable for operation of data given below:-
1
-
-
Total dynamic head 176.5 mtr.
-
-
-
Discharge (Q) 3.7649 LPS
-
-
-
Length of rising main (in metres)485mtr.
-
-
-
Dia. of rising main = 65 mm
-
-
-
Stand by only supplied no installation(including testing),submersible pumping set of reputed make such as KSB/BS/ Johnston/Kirloshker/Worthington/Oswal/Sabar Brand conforming to latest relevent BIS code.
1
-
-
Providing and fixing of auto control panel with push button star delta starter for submersible pump of L&T and reputed make fabricated with M.S. sheet and angle stand duly painted and complete with internal wiring, comprising of main switch of suitable Amp with suitable cable core., T.P. volte meter, ameter, hour run metre, phase indicating lamps with GMS based, remote start/stop operation call/SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hour in a day, imbuilt protection against overload/ undervoltage, dry run, single phase preventer, inbuilt GPS tracker, phase reversal configurable volt/current limits with a facility to access the systemthrough minimum 10 No. authenticate mobile Nos. complete in all respect, including intire carriage of materials all leads and lifts, installation and testing at site with entire saisfaction of engineer-in-incharge. (NOTE:- All mettars to be installed shall be Digital)
-
-
-
Providing and fixing double flanged Cast steel Reflux valve of reputed make ISI marked ASA 40mm dia. of withstanding normal seat pressure and as per IS 5312-1884 P-I with upto date amendments class ASA-300 for rising main including the cost of nuts, bolts , champion sheet complete in all respect and as per direction of Engineer-in-Charge with mating flange, Nut Bolts, Gaskets etc. complete in all respect.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements