Himachal Pradesh Irrigation And Public Health Department Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender

Works
Metals
Eprocure
Opening Date10 Dec 2020
Closing Date23 Dec 2020
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Augmentation Of Wss Pandli Chunani Kuklah In Gp Kashoud From Khudagi Khad In Tehsil Balichowki District Mandi

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying cement concrete 1:3:6 ( 1cement:3sand: 6 graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts.

91.05

-

-

... More
Providing and laying cement concrete 1:11/2 :3 ( 1cement: 1 1/2 sand: 3graded stone aggregate 20 mm nominal size )and curing complete excluding the cost of form work and reinforcement with in all leads and lifts and entire satisfaction of Engineer incharge in:-

-

-

-

... More
Foundation, footings bases of columns and the like and mass concrete.

74.1

-

-

... More
Walls any thickness but not less than 0.1 mtr. thickness attached pillasters, buttresses plinth and string courses etc. from top of foundation level upto floor two level

108.29

-

-

... More
Suspended floors, roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilivers up to floor two level.

1.2

-

-

... More
Suspended floors, roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilivers up to floor two level. ( Dome Slab)

18.83

-

-

... More
Lintels, beams, girders, bressumers and cantilevers up to floor two level.

3.23

-

-

... More
Providing form work with steel plates 3.15mm thick welded with angle iron 30x30x5mm so as to give a fair finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4mtrs. and removal of the same for in-situ reinforced concrete and plain concrete work in all leads and lifts.

-

-

-

... More
Vertical surface such as walls(any thickness) partitions and the like including attached pillasters buttresses, plinth and string courses and the like (Plain wall)

1290.58

-

-

... More
Flat surface such as soffits of suspended floors, roofs, landing and the like floor etc. upto 200mm in thickness as per direction and to the entire satisfaction of the Engineer-in-charge.

207.07

-

-

... More
Beams,cantilivers,girders and lintels sides and soffits of beams,beam haunchings, cantilivers , girders, bressumers and lintels not exceeding 1 metre in depth.

65.48

-

-

... More
Sloping battering surfaces including folded plates: where inclination to horizontal does not exceed 30 Degree requiring shuttering only to the under side with in all leads and lifts.

122.7

-

-

... More
Edges of slabs and breaks in floor and wall under 20 cm wide in all leads and lifts.

124

-

-

... More
Providing form work of ordinary timber plankings so as to give a rough finish including centering ,shuttering, propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plaiin concrete work in:-

-

-

-

... More
Arches, domes, up to all span in all leads and lifts.

198.28

-

-

... More
Providing and laying tor steel reinforcement for RCC work including bending, binding and placing in position complete including cost of binding wire upto floor two level in all leads and lifts.

19362.4

-

-

... More
Providing and laying cement concrete 1:2:4(1Cement :2 sand:4 graded crushed stone aggregate 20mm nominal size and curing completre excluding the cost of form work and reinforcement for reinforced concrete work in all leads and lifts in :-

-

-

-

... More
Suspended floors, roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilivers up to floor two level.

45.49

-

-

... More
Fixing of GI pipe for inlet, outlet, over flow and scour pipes in all leads and lifts complete in all respect including cutting and welding of pipe: -

-

-

-

... More
50mm dia

6

-

-

... More
65 mm dia

110

-

-

... More
Providing and fixing Gum Metal wheel valve with Wheel in all leads and lifts : -

-

-

-

... More
50mm dia nominal bore.

1

-

-

... More
65mm dia nominal bore.

15

-

-

... More
1.80 metre high fencing with 2.50 metre angle iron post 50x50x6mm 2.50 metre centre to centre with nine horizontal lines and two diagonals of galvanised steel bar bed wire (IS:278-1962 type-I) weighing 9.38 kg/per 100 metre (minimum) strained and fixed to posts with G.I. staples, including coal tarring of ballies complete in all leads and lifts.

848.81

-

-

... More
Steel work welded in built up sections, trusses and framed work including cutting,hoisting, fixing in position and applying a priming coat of red lead paint :- in gratting, framed guard bar, ladders, railing brackets and similar works in all leads and lifts.

525

-

-

... More
Providing and fixing 3.15mm thick MS sheet man hole cover fixed with 50x50x6mm angle iron frame 500x500mm with welding including hold fast 25x6mm 150mm long, handles 150mm long 8mm dia bar and locking arrangement complete in all leads and lifts.

5

-

-

... More
Providing and fixing cast iron spun spigot and socket soil ventilating pipe lead cauled joints to be measured and paid for separately 100mm dia

6

-

-

... More
Providing and fixing CI Cowl 100mmdia complete in all respect

6

-

-

... More
Providing and placing in horizontal layers filtering media duly graded screened washed and cleaned as specified by the Engineer-in-charge including all leads and lifts.

-

-

-

... More
Top layer:- Fine sand screened, cleaned, washed and graded effective size 0.20 to 0.40 with uniformity co-efficient 2 to 3).

116.71

-

-

... More
2nd layer:- Coursed sand screened, washed and graded from 3mm to 6mm

15.56

-

-

... More
3rd layer :- Bajari screened, washed and graded from 6mm to 20mm

15.56

-

-

... More
4th layer :- Bajari screened, washed and graded from 20mm to 25mm

15.56

-

-

... More
Bottom layer :- Broken stone screened washed and graded from 50mm to 75mm

23.34

-

-

... More
Providing and placing 1st class standard bricks in filter bed in to leayer so as to make cross drains as per direction of the Engineer in Charge.

13188

-

-

... More
Randum rubble masonary polygonal rubble masonary (uncoursed brought to courses with hard stone of approved quality in foundation and plinth including leveling up with cement concrete 1:6:12 (1cement: 6 sand: 12 graded stone aggregate 20mm nominal size) in cement mortar 1:6 (1cement: 6 sand) including all leads and lifts.

64.86

-

-

... More
Boulder filling behind retaining wall under floor with in all leads and lifts complete in all respect.

15.38

-

-

... More
Brick work using common burnt clay building bricks masonary in super structure above plinth in cement mortor 1:4(1cement :4sand) complete in all respect in all leads and lifts (i) 2nd class bricks

73.04

-

-

... More
Provding wood work in frames of doors,windows,and other frames wrought,framed and fixed in position in all leads and lifts :- 1st class Deodar wood

1

-

-

... More
Providing 40x3mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts & nuts and wooden plugs and embeding in cement concrete block 30x10x15cm 1:3:6 ( 1cement: 3 sand :6 graded stone aggregate 20mm nominal size complete in all respect in all leads and lifts.

96

-

-

... More
Providing and fixing panneled glazed or panelled and glazed shutters for doors, windows and clerestory windows,including black enamelled iron butt hinges with necessary screws. 45 mm thick. 2nd class deodar wood.

35.1

-

-

... More
Providing and fixing MS grills of required pattern in wooden frames of windows etc. with MS flats, square or round bar with round headed bolts and nuts or by screws (Plain grills)

208

-

-

... More
Cement concrete flooring 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) laid in one layer finished with a floating coat of neat cement with in all leads and lifts : - 40 mm thick.

105.11

-

-

... More
6mm cement plaster to ceiling in cement mortar 1:3 (1cement :3sand) inall leads and lifts.

154.26

-

-

... More
20mm cement plaster in single coat on rough side of brick/ concrete/ stone walls for interior plastering upto floor two levels including arrises internal rounded angles chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:6 (1cement:6sand) in all leads and lifts.

278.86

-

-

... More
15mm cement plaster in single coat on rough side of brick /concrete stone walls for interior plaster up to floor two elvel including arrises, internal rounded angles, chamfers ad/or rounded angles not exceediong 80mm in girth and finished even and smooth in C.M 1:4 (1Cement :4 Sand)

23.04

-

-

... More
White washing with lime on undecorated wall surfaces two coats give an even shade including thoroughly brooming the surface to remove all dirt dust and other foregin matter in walls in all leads and lifts.

1266.73

-

-

... More
Distempering with dry distemper of approved brand and manufacture (two coats) and of required shade on undecorated wall surfaces to give an even shade sand papered smooth complete in all respect in all leads and lifts.

278.86

-

-

... More
Applying priming coat on new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil,greese,dirt and other foreign matters,sand papering and knotting.Ready mixed paint brushing wood primer pink.

78.92

-

-

... More
Painting two coats (excluding priming coat) on new wood and wood based surfaces,with enamel paint to give an even shade including cleaningthe surface of dirt ,dust and other foreign matters sand papering and stopping with enamel paint other than white

78.92

-

-

... More
Providing and fixing anodised MS sliding door bolts with bolts and nuts screws etc. complete.: - 250*16 mm

6

-

-

... More
Providing and fixing anodised MS tower bolts ( barrel type) with screws etc. complete.

-

-

-

... More
250 * 10 mm

8

-

-

... More
200 * 10 mm

64

-

-

... More
Providing ad fixing anodised MS handles with necessary screws etc. complete.: - 125 mm

48

-

-

... More
Providing ad fixing anodised MS hooks and eyes with necessary screws etc. complete.: -250 mm

36

-

-

... More
Providing plinth protection 50 mm thick in cement concrete 1:3:6 ( 1 cement, 3 sand,6 graded stone aggregate 20 mm nominal size ) with in all leads and lifts complete in all respect.

58.68

-

-

... More
Proving under layer for plinth protection of 75 mm thick(unconsolidated) bed dry brick/stoneAggregated 40 mm nominal size will rammed with rammed and consolidated and grouted with fine sand including preparation of ground.

47.28

-

-

... More
Half bricks masonary in common burnt clay building bricks in 1:4 (1cement :4 sand) in super structure above plinth level upto all floor level in all leads and lifts (2nd class )

34.76

-

-

... More
Providing and fixing vitreous china wash down water closet (Indian Type, W.C pan) with integral P or S trap including jointing the trap with soil pipe in cement mortar 1 : 1 ( 1 cement 1 sand) ( Seat and cover to be measured and paid for separately) (White colour)

2

-

-

... More
Providing and fixing 32 mm CP brass waste pipe for wash basin in all leads and lifts.

2

-

-

... More
Providing and fixing 10/12.5/15 litres vitreous china low level flushing cistern with a pair of CI or mild steel brackets complete with fittings such as lead valve less syphon 15mm nominal size brass ball valve with polythene float CP brass handle unions and couplings for connection with inlet , out let and over flow pipes 40mm dia CP flush bend including cutting holes in walls and making good the same and connecting the flush bend with cistern and closet (overflow) pipe to be measured and paid for separately.

2

-

-

... More
Providing & fixing viterious china wash basin with single hole for pillar tap with CI or MS bracket painted white including cutting hole including good the same excluding fitting Cera sanitary work (cornet) white 550x400 white

2

-

-

... More
Providing and fixing floor trap for wash basin and sink in all leads and lifts.

2

-

-

... More
Providing and fixing 600mmx450mm beveled edge mirror of superior glass mounted on 6mm thick A.C. sheet or ply wood sheet and fixed to wooden plugs with C.P. brass screws and washers in all leads and lifts.

2

-

-

... More
Providing and fixing PVC pipe ISI marked 100mm dia in all leads and lifts.

30

-

-

... More
Providing and fixing GI union 15mm dia ISI marked in all leads and lifts.

8

-

-

... More
Providing and fixing GI Elbow 15mm dia ISI marked in all leads and lifts.

16

-

-

... More
Providing and fixing G.I. Tee15mm equal ISI marked in all leads and lifts.

10

-

-

... More
Providing and fixing G.I. Socket 15mm dia ISI marked in all leads and lifts.

12

-

-

... More
Providing and fixing to wall ceiling and floor galvanised mild steel tubes (Medium grade) tube fittings and clamp including making good the wall ceiling and floor in all leads and lifts.) 15 mm nominal bore

60

-

-

... More
Providing and fixing G.I. Nipple 15mm dia ISI marked in all leads and lifts.

8

-

-

... More
Providing and Fixing of water storage tank sintex having of capacity 500 liters with necessary fittings including over flow pipes, scour pipes etc. inlet and outlet and inside paint of required size for inlet or outlet and inside paint of approved quality complete including hoisting complete in all respects.

2

-

-

... More
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required (Group A)

20

-

-

... More
Wiring for power plug with 2x4sq.mm PVC insulated 9head resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit alongwith 1 to 4 Sq.mm HRFRLS/PVC insulated single core copper conductor cable for earthing as required.

36

-

-

... More
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. : - 2x1.50 Sq. mm.

80

-

-

... More
Supplying and fixing of following way single pole and neutral steel sheet MCB distribution board 240 volts on surface/ recess complete with tinned copper busher wire set neutral link earth bar din bar detachable gland plate blanking plate cable identification levels interconnection phosphaized and power painted including earting etc., as required.

2

-

-

... More
Supplying and erection of 6 Amps. to 32 Amps. Rating 10 KA breaking capacity, 240 volts, C curves, miniature circuit beaker of following poles in the existing MCB DB complete with connections etc. as required Single pole Cat. A

8

-

-

... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (63 amp. CAT - A)

2

-

-

... More
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps Cat A

2

-

-

... More
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:- Ceiling Fan 1200 mm sweep, Category-A

4

-

-

... More
Supplying and fixing plain pendent with 16/0.20 mm twin twisted, flexible, PVC insulated, cotton braided, copper cable and brass pendent holder including connections etc. as required:-

8

-

-

... More
Providing and fixing shock proof slim decorative extruded fixture with domestic electronic ballast, suitable for 36 watt FTL (T8), complete with all accessories (excluding the T-8 Tube), connections, testing and commissioning etc. as required :- 1 x36 watt-FTL(T8) (Category-A)

4

-

-

... More
Providing and fixing following type of CFL rod lighting Luminaires Epoxy black powder coated sheet steel housing with epoxy white powder coated XRCA sheet steel geartray clear a crylic cover aluminium reflector (but excluding the cost of CFL) complete with all accessories connection, testing & commissioning etc. as required : - 1x85 watt CFL fixture.

4

-

-

... More
Providing and fixing 85 watt CFL in existing fixture in all leads and lifts.

4

-

-

... More
Providing, welding, laying, testing and comissioning at site in trenches bevelled ended BIS marked API pipe as per ISO 3183-2007 latest with upto date amendments of following dia with steel grade 5L (std)x42, having wall thickness as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in a random lenghts of 5.0 to 7.0 mtr. The pipe ends shall be bevelled suitably for butt welding, including the cost of joining with butt welding confirming IS: 816-1969 or latest as applilcable with upto date amendments in three layers (leakproof) at site of work k with welding rods of standard make i.e. of Advani Overlikon/Over cords/s make conforming to IS 814-1991 including die penetration test at site of work & all allied accessories whatever required for welding at site including tail pieces, tees, bends of all degrees & other specials manufactured from parent pipes as applicable to the particular reach & of approved specification and cutting of pipes wherever required as per site requirement i/c carriage in all leads & lifts and as directed b y Engineer-in-charge. The pipe shall have zinc coating inside & outside confirming to IS: 4736-1986 or latest with upto date amendments & shall be engraved with L290 or X42. The laying shall confirm to BIS: 5822-1970 or latest with upto date amendments DP test shall be performed to the entire satisfaction of the Engineer-in-charge (cost of MS flanges/Nut and bolts. gasket to be measured & paid for separately under item No. 138) including all leads and lifts and as per entire satisfaction of the Engineer-in-charge.

-

-

-

... More
125 mm dia, API 5L (Std)x42 , T-7.90 mm (RD 0.0 to 200) 1st stage

200

-

-

... More
125mm dia, API 5L (Std)x42 , T-6.60 mm (RD 200 to 500) 1st stage

300

-

-

... More
125mm dia, API 5L (Std)x42 , T-5.60 mm (RD 500 to 1000) 1st stage

500

-

-

... More
80mm dia, API 5L (Std)x42 , T-4.00 mm (RD 0 to 200) 2nd stage

200

-

-

... More
Providing and fixing M.S. flanges of various dia (nominal bore) of following Flange Tables confirming to IS 6392-1971 or latest with up to date ammendments to API/ MSERW after every 100 mtr. pipe or as per site requirement including cutting of of pipes wherever required, welding in three layers (leak proof) confirming to specifications as prescribed in relvent I.S. Code i.e. IS 816-1969 or latest as applicable with up to date ammendments with nuts, bolts & washers & specials etc. confirming to IS-1963 or latest with up to date ammendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticorosive paints complete in all respect including all leads and lifts and as per entire satisfaction of Engineer - in - charge

-

-

-

... More
125 mm dia, API 5L (Std)x42 , T-7.90 mm, FT-38 (RD 0.0 to 200) 1st stage

2

-

-

... More
125mm dia, API 5L (Std)x42 , T-6.60 mm, FT-38 (RD 200 to 500) 1st stage

3

-

-

... More
125mm dia, API 5L (Std)x42 , T-5.60 mm, FT- 34 (RD 500 to 1000) 1st stage

5

-

-

... More
80mm dia, API 5L (Std)x42 , T-4.00 mm, FT-34 (RD 0 to 200) 2nd stage

2

-

-

... More
Laying, jointing and testing in trenches to be leveled to grades, IS marked GI pipes of following diameters confirming to IS: 1239-1990 ( Part-II) (latest with upto date amendments ) having minimum wall thickness as per class of pipe specified below jointed with butt welding to done on both ends according to relevant BIS standards and detailed specifications including al kinds of short pieces, bends, tees and other special etc. made from parent tubes and jointing with butt welding in three layers as applicable for the particular reach and of technical specification as per site conditions including flushing, cleaning and hydraulic testing as per the direction of the Engineer-in-charge.

-

-

-

... More
125mm dia, (H) (RD 1000 to 1500) 1st stage

500

-

-

... More
125mm dia, (M) (RD 1500 to 1950) 1st stage

450

-

-

... More
80mm dia, (H) (RD 200 to 500) 2nd stage

300

-

-

... More
80mm dia, (M) (RD 500 to 1600) 2nd stage

1100

-

-

... More
Providing and fixing M.S. flanges of various dia (nominal bore) of following flange Tables confirming to IS: 6392-1971 or latest with upto date ammendments to G.I. pipe after every 100 mtr. Pipe or as per site requirement including cutting of pipes wherever required, welding in three layers (leak proof) confirming to specifications as perescribed in relevant IS code i.e. IS: 816-1969 or latest as applicable with upto date ammendments with nuts, bolts, washers & specials etc. confirming to IS: 1963 or latest with upto date ammendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticorrosive paints complete in all respect including all leads and lifts and as per entire satisfaction of the Engineer-in-charge

-

-

-

... More
125mm dia, (H) Ft-28 (RD 1000 to 1500) 1st stage

5

-

-

... More
125mm dia, (M) Ft-28 (RD 1500 to 1950) 1st stage

4

-

-

... More
80mm dia, (H), FT-28, (RD 200 to 500) 2nd stage

3

-

-

... More
80mm dia, (H), FT-28 (RD 500 to 1000) 2nd stage

5

-

-

... More
80mm dia, (M), FT-17 (RD 1000 to 1600) 2nd stage

5

-

-

... More
1st STAGE. Supply, errection, testing & commissioning of horizontal spindle,horizontal split casing,radial split Single,/Multistages centrifugal pumps of standarad make such as KSB/ Mather & Platt/ Jyoti /Kirloskar/ Beaconweir /BS & BE conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to handle clear water having turbidity up to 50 ppm. with impelleres,casing ring, priming funnels & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel /Mild steel to BHEL /Kirlokar/ NGEF/ Crompton / Siemen/Jyoti /GEC make slip ring /squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below, including all leads and lifts and as per entire satisfaction of Engineer - in - charge 4 Sets (2 Working and 2 Standby) Total Head :- 763.03 mtrs. Capacity :- 5.66 lps of each pump set. ( 2 Nos. pump set will be run at a time and 2 Nos. will act as standby).Dia of R/Main:- 125 mm.

4

-

-

... More
SITE CONDITIONS:- Location of Site:-The altitude of place in which the motor is intended to work in ordinary service (in 955 metres) :- T Turbidity (if any):- 1.5 NTU.o be filled by the Engineer Incharge.Humidity:- Weather generally remains humid during monsoon season. Nature of atmosphere:- Detail of quality of water:- Clear cold water Water free from sand or not :- Yes Water corosive or not :- Not NPSH available:- Positive suction. Any other information or requirement:-

-

-

-

... More
OPERATING CONDITIONS:- Type of current:- AC three/single phase Operating frequency:- 50 HZ Rated voltage:- 400 (+/-) 10% volts System of earthing if any to to be adopted.:- Double loop earthing as per BIS 3043-1987 latest with upto date ammendments No. of working hours per day:- 8 hours Speed of revolution in RPM:- To be quoted by tenderer Direction of rotation:- To be quoted by tenderer The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service.:- 35 Degree Centigrade

-

-

-

... More
MOTOR:- Ref. to BIS code:- BIS 325-1978 read with BIS 900-1992 (latest)with upto date ammendments Type of enclosure of motor:- SPDP(as per BIS 4691-1985 (latest) Type of duty:- Continuous as per IS-12824-1989 or latest with up to date ammendments Mechanical out put in KW:- Suitable for driving centrifugal pumps required for duties specified against pumps.To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. Class of insulation:- Class ~B~ Max.permissible temp.rise of motor reqd. if different from given in B(viii) above:- 16.5O Particulars of test reqd. & where they are to be conducted:- As per terms & conditions Motor :-slip-ring Details of shaft extension reqd.:- Just sufficient to provide direct drive by flexible coupling to pump. Type of slip-ring gear whether continouly rated or for starting purposes only & whether to be fitted with brush lifting or short circuit arrangements or both if interlocks are rquired.:- Continously rated for Squirrel cage/ Slipring motor Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit.:- Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current. Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelrated & No.of starts during a specified period.:- Sufficient to work the pump offered Where possible fault capacity of the system to which the motor is connected.:- The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations.

-

-

-

... More
PUMP :- BIS 1520-1980 read with BIS 9137-1978 both with up to date ammendments Nos of pumps reqd.:- 2Nos pump 1 to work at a time independently and 1 will be act as stand bye. Spare parts required:- For 5 years normal maintenance as recommended by manufacturer. Optional fittings reqd.:- Air cock for exahausting air from each stage.

-

-

-

... More
PUMP OPERATING CONDITIONS:- Capacity (in LPS) 5.66 LPS by each pump set Total head (in Mts).:- 763.03 mtrs. If total head is not known then following details be provided:- i) Static head 734 mtrs) ii) Minimum depth of water( in mtrs) iii) Variation in water level ( in mtrs) iv) Ground level to max. water level ( in mtrs) v) Ground level to delivery point ( in mtrs) vi) Pressure in the suction tank (in Kg/cm^2 ) vii) Pressure in the delivery tank (in Kg/cm^2 ) Length of R/Main (in metres):-1950 mtrs Dia of R/Main (in mm):- 125 mm. Drive arrangement:- Direct through flexible coupling on a common base plate Drive type:- Electric driven NPSH reqd.:- To be quoted by the tenderer Limits of total head in which the pump is reqd. to operate.:- (-) 15% to (+) 10% of total head. Suction/delivery size of pump:- To be specified by the tenderer Efficiency of pump at:- To be specified by the tenderer a) duty head b) (+)10 % head c) (-) 15 % head Material of construction:- To be specified by the tenderer (manufacturer~s certficate to be appended)

-

-

-

... More
Ammeter for AC supply of appropriate capacity suitable for the above specified motor in Annexure, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

4

-

-

... More
Frequency Meter for AC supply of appropriate capacity suitable for the above specified motor , including all leads and lifts and as per entire satisfaction of Engineer - in - charge

4

-

-

... More
Voltmeter AC supply of appropriate capacfity suitable for the above specified motor , including all leads and lifts and as per entire satisfaction of Engineer - in - charge

4

-

-

... More
MCCB of appropriate capacity suitable for the above specified motor for mains ON/Off to the panel, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

4

-

-

... More
Indicator for mains ON-OFF, System Standby- Overload - Run, Sump Empty - Full, RYB Phase, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

4

-

-

... More
Motor Protection Circuit Breaker for 3 phase/3 wire under voltage/over voltage protection, short circuit protection, overload protection, phase loss, phase reversal protection and motor disconnect function, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

4

-

-

... More
Rust free powder coated Control panel suitable for housing all the above listed electrical and electronics components, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

4

-

-

... More
Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

4

-

-

... More
Supply of Kirloskar/Leader/KSB/fouress make of cast steel double flanged ASA 600 sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure. & conforming to BIS/API-standards with up to date ammendments for delivery line of pump (including one No for common header). (NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class ASA 600 (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600) compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

4

-

-

... More
Supply of Kirloskar/Leader/KSB/pelicon/Fouress make of suitable size cast steel double flanged ASA 600 swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 31(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class ASA 600 (seat pressure 52 Kg/cm^2) as per BS-1414 (API 600) compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

4

-

-

... More
Supply of Kirloskar/Leader/KSB/Pelocon/Fouress make of suitable size Cast Steel double flanged ASA 600 swing check type reflux valve having bye pass arrangement & size equal to dia of R/main for withstanding nominal seat pressure for Rising main. NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class ASA 600 (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600) compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

4

-

-

... More
Supply of Kirloskar/Leader/KSB/Pelocon/Fouress make cast iron flanged Sluice valve for suction pipe having size one larger than suction size of pump such that velocity of flow is not more than 3.00 mtr/sec. with strainer of dia equal three to four times of dia of suction pipe conforming to BIS/API-standards or latest with up to date ammendments. NOTE:- The C.I sluice valve PN 1.6 as per IS 2906-1998).compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

4

-

-

... More
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost, including all leads and lifts and as per entire satisfaction of Engineer - in - charge ( For 4 No pump sets).

1

-

-

... More
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost, including all leads and lifts and as per entire satisfaction of Engineer - in - charge ( For 4 No pump sets).

1

-

-

... More
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,copper wiring & 32x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

1

-

-

... More
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer), including all leads and lifts and as per entire satisfaction of Engineer - in - charge

4

-

-

... More
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/ PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

4

-

-

... More
P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 31 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that velocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump, including all leads and lifts and as per entire satisfaction of Engineer - in - charge NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge.

1

-

-

... More
Supply of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.

4

-

-

... More
2nd stage Supply, errection, testing & commissioning of horizontal spindle,horizontal split casing,radial split Single,/Multistages centrifugal pumps of standarad make such as KSB/ Mather & Platt/ Jyoti /Kirloskar/ Beaconweir /BS & BE conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to handle clear water having turbidity up to 50 ppm. with impelleres,casing ring, priming funnels & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel /Mild steel to BHEL /Kirlokar/ NGEF/ Crompton / Siemen/Jyoti /GEC make slip ring /squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below, including all leads and lifts and as per entire satisfaction of Engineer - in - charge 2 Sets (1 Working and 1 Standby) Total Head :- 516.97 mtrs. Capacity :- 4.72 lps of each pump set. ( 1 No. pump set will be run at a time and 1 No. will act as standby). Dia of R/Main:-80 mm.

2

-

-

... More
SITE CONDITIONS:- Location of Site:- The altitude of place in which the motor is intended to work in ordinary service (in 955 metres) :- To be filled by the Engineer Incharge. Nature of atmosphere:-Detail of quality of water:- Clear cold waterWater free from sand or not :- Yes Water corosive or not :- Not Turbidity (if any):- 1.5 NTU. NPSH available:- Positive suction. Any other information or requirement:-

-

-

-

... More
OPERATING CONDITIONS:- Type of current:- AC three/single phase Operating frequency:- 50 HZ Rated voltage:- 400 (+/-) 10% volts System of earthing if any to to be adopted.:- Double loop earthing as per BIS 3043-1987 latest with upto date ammendments No. of working hours per day:- 8 hours Speed of revolution in RPM:- To be quoted by tenderer Direction of rotation:- To be quoted by tenderer The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service.:- 35 Degree Centigrade

-

-

-

... More
MOTOR:- Ref. to BIS code:- BIS 325-1978 read with BIS 900-1992 (latest)with upto date ammendments Type of enclosure of motor:- SPDP(as per BIS 4691-1985 (latest) Type of duty:- Continuous as per IS-12824-1989 or latest with up to date ammendments Mechanical out put in KW:- Suitable for driving centrifugal pumps required for duties specified against pumps.To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. Class of insulation:- Class ~B~ Max.permissible temp.rise of motor reqd. if different from given in B(viii) above:- 16.5O Particulars of test reqd. & where they are to be conducted:- As per terms & conditions Motor :-slip-ring Details of shaft extension reqd.:- Just sufficient to provide direct drive by flexible coupling to pump. Type of slip-ring gear whether continouly rated or for starting purposes only & whether to be fitted with brush lifting or short circuit arrangements or both if interlocks are rquired.:- Continously rated for Squirrel cage/ Slipring motor Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit.:- Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current. Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelrated & No.of starts during a specified period.:- Sufficient to work the pump offered Where possible fault capacity of the system to which the motor is connected.:- The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations.

-

-

-

... More
PUMP :- BIS 1520-1980 read with BIS 9137-1978 both with up to date ammendments Nos of pumps reqd.:- 2Nos pump 1 to work at a time independently and 1 will be act as stand bye. Spare parts required:- For 5 years normal maintenance as recommended by manufacturer. Optional fittings reqd.:- Air cock for exahausting air from each stage.

-

-

-

... More
PUMP OPERATING CONDITIONS:- Capacity (in LPS) 4.72 LPS by each pump set Total head (in Mts).:- 516.973 mtrs. If total head is not known then following details be provided:- i) Static head 476 mtrs) ii) Minimum depth of water( in mtrs) iii) Variation in water level ( in mtrs) iv) Ground level to max. water level ( in mtrs) v) Ground level to delivery point ( in mtrs) vi) Pressure in the suction tank (in Kg/cm^2 ) vii) Pressure in the delivery tank (in Kg/cm^2 ) Length of R/Main (in metres):-1600 mtrs Dia of R/Main (in mm):- 80 mm. Drive arrangement:- Direct through flexible coupling on a common base plate Drive type:- Electric driven NPSH reqd.:- To be quoted by the tenderer Limits of total head in which the pump is reqd. to operate.:- (-) 15% to (+) 10% of total head. Suction/delivery size of pump:- To be specified by the tenderer Efficiency of pump at:- To be specified by the tenderer a) duty head b) (+)10 % head c) (-) 15 % head Material of construction:- To be specified by the tenderer (manufacturer~s certficate to be appended)

-

-

-

... More
Ammeter for AC supply of appropriate capacity suitable for the above specified motor in Annexure, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

2

-

-

... More
Frequency Meter for AC supply of appropriate capacity suitable for the above specified motor , including all leads and lifts and as per entire satisfaction of Engineer - in - charge

2

-

-

... More
Voltmeter AC supply of appropriate capacfity suitable for the above specified motor , including all leads and lifts and as per entire satisfaction of Engineer - in - charge

2

-

-

... More
MCCB of appropriate capacity suitable for the above specified motor for mains ON/Off to the panel, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

2

-

-

... More
Indicator for mains ON-OFF, System Standby- Overload - Run, Sump Empty - Full, RYB Phase, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

2

-

-

... More
Motor Protection Circuit Breaker for 3 phase/3 wire under voltage/over voltage protection, short circuit protection, overload protection, phase loss, phase reversal protection and motor disconnect function, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

2

-

-

... More
Rust free powder coated Control panel suitable for housing all the above listed electrical and electronics components, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

2

-

-

... More
Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

2

-

-

... More
Supply of Kirloskar/Leader/KSB/fouress make of cast steel double flanged ASA 600 sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure. & conforming to BIS/API-standards with up to date ammendments for delivery line of pump (including one No for common header). (NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class ASA 600 (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600) compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

2

-

-

... More
Supply of Kirloskar/Leader/KSB/Fouress make of suitable size cast steel double flanged ASA 600 swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 31(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class ASA 600 (seat pressure 52 Kg/cm^2) as per BS-1414 (API 600) compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

2

-

-

... More
Supply of Kirloskar/Leader/KSB/Fouress make of suitable size Cast Steel double flanged ASA 600 swing check type reflux valve having bye pass arrangement & size equal to dia of R/main for withstanding nominal seat pressure for Rising main. NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class ASA 600 (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600) compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

1

-

-

... More
Supply of Kirloskar/Leader/KSB/Fouress make cast iron flanged Sluice valve for suction pipe having size one larger than suction size of pump such that velocity of flow is not more than 3.00 mtr/sec. with strainer of dia equal three to four times of dia of suction pipe conforming to BIS/API-standards or latest with up to date ammendments. NOTE:- The C.I sluice valve PN 1.6 as per IS 2906-1998).compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

2

-

-

... More
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost, including all leads and lifts and as per entire satisfaction of Engineer - in - charge ( For 2 No pump sets).

1

-

-

... More
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost, including all leads and lifts and as per entire satisfaction of Engineer - in - charge ( For 2 No pump sets).

1

-

-

... More
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,copper wiring & 32x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

1

-

-

... More
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer), including all leads and lifts and as per entire satisfaction of Engineer - in - charge

2

-

-

... More
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/ PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments, including all leads and lifts and as per entire satisfaction of Engineer - in - charge

2

-

-

... More
P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 31 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that velocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump, including all leads and lifts and as per entire satisfaction of Engineer - in - charge NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge.

1

-

-

... More
Supply of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.