Himachal Pradesh Irrigation And Public Health Department Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date7 Mar 2022
Closing Date21 Mar 2022
Tender Amount₹ 1,95,56,736 
Notes
Download

Costs

Summary

Improvement Of Distribution System Of Lis Dobber Patta And Lis Rail In Tehsil Nadaun Distt. Hamirpur

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying cement concrete 1:3:6(1cement:3sand:6 graded stone aggregate 40mm nominal size and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts.

64.26

-

-

... More
Providing and laying cement concrete 1:4:8(1cement:4sand:8 graded stone aggregate 40mm nominal size and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts.

11.31

-

-

... More
Providing form work or ordinary timber plankings , so as to give a fair finish including centring,shuttering,strutting and propping etc. with wooden battens and ballies height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for insitu-reinforced concrete and plain.

-

-

-

... More
Foundation footings, basis of column etc mass concrete .

93.6

-

-

... More
Beams, cantilevers, girders and lintels such as soffits of beams, beams haunching, cantileers girder, bressumers and lintels of all height/thickness.

432

-

-

... More
Flat surfaces such as soffits of suspended floors, roofs, landings and the like floors etc 200mm.

69.58

-

-

... More
Providing and laying cement concrete 1:1.5:3(1cement:1.5sand:3 graded stone aggregate 20mm nominal size)and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in:-

-

-

-

... More
In foundation, footings, basis of columns and the like and mass concrete in all leads and lifts as per direction and to the entire satisfaction of the Engineer-in-charge.

65.12

-

-

... More
Walls (any thickness) but not less than 0.10cm thickness including attached pilasters, buttresses, plinth and string courses from top of foundation upto all floor level as per direction and to the entire satisfaction of the Engineer-in-charge.

101.72

-

-

... More
Columns, Pillars, posts and struts floor two level.

44.42

-

-

... More
Beams, cantilevers, girders & lintels, sides &soffits of beams, haunching, cantilevers, bressumers 1.00 mtrs ind epth in all heights fromfloor.

0.53

-

-

... More
Suspended floors, roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilevers upto all floor level as per direction and to the entire satisfaction of the Engineer-in-charge.

42.79

-

-

... More
Providing and laying cement concrete 1:2:4(1cement:2sand:4 graded stone aggregate 20mm nominal size)and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts.

59.08

-

-

... More
Providing, Laying mild or tor steel reinforcement for RCC. Work including bending binding and placing in position complete upto floor two level Tor steel in all leads and lifts.

24746.7

-

-

... More
Brick work using common burnt clay building bricks in super structures in cement mortar 1:6(1cement:6sand)(2nd class)

63.65

-

-

... More
15mm cement plaster in single coat of rough sides of bricks/concrete stone walls for interior plastering upto floor two level including arrises internal rounded angles chamfer and rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:4 (1cement:4sand) in all leads and lifts.

127.1

-

-

... More
Providing and fixing pressed steel doors frames manufactured from commercial mild steel sheet of 1.25mm thickness including hinges jumb lock jamb,beed and if reuired angle threshold of mild steel angle of section 50X25 mm or base ties of 1.25 mm pressed mild steel welded or regidly fixed together by mechanical means,adjustable lugs with split and tails to each jamb including steel butt hinges 2.5 mm thick with guards,lock strike plate and shock absorber as specified and applying a coat of approved steel primer after pretretment of the surface as directed by Engineer-in-Charge.

-

-

-

... More
Profile - A

16.44

-

-

... More
Providing and fixing of 1mm thick M.S. sheet door with frame of 40mmx40mmx6mm angle iron 3.15mm M.S. gusset plate at the junction and corners including all necessary fiting complete including appplying a priming coat ofred lead paint using flat 30mmx6mm for diagonal braces and control cross/pieces complete in all respect.

5.34

-

-

... More
Beam ISMB 450 for hoisting chain pully including chain pulley arrangement complete in all respect.

13.11

-

-

... More
Providing and fixing 500mm diameter C.I. manhole cover withf rame of medium duty 116 kg weight

4

-

-

... More
Providing and fixing of steel bar cage for fastening of pump with piers of 300mm dia of mesh size 50mmx 50mm, 16mm square steel bars complete in all respect.

72

-

-

... More
Providing and fixing M.S handles with necessary screws etc. complete

-

-

-

... More
125mm

52

-

-

... More
100mm

8

-

-

... More
Providing and fixing M.S tower bolts (Barrel type) with necessary screw etc. complete in all leads and lifts.

-

-

-

... More
200x10mm

20

-

-

... More
150x10mm

44

-

-

... More
100x10mm

8

-

-

... More
Providing and fixing anodized alminium sliding door bolts anodized transparent for type required and bright shade with necessary screw etc. complete. 250x16mm

6

-

-

... More
White washing with lime on undecorated walls surface (two coats)to give an even shade including throughly brooming the surface dirt dust mortar dirt and other foreign matter in all leads and lifts.

451.78

-

-

... More
Providing and fixing M.S.fan clamp (Type-I)of 16mm dia M.S. including bend upto shape with broken end in RCC. Slab door painting the exposed position of trap all as per standard design complete in all leads and lifts.

4

-

-

... More
Miscellaneous expenses for 50 m approach channel, ISMB 450, M.S. railing, RS joist, Chain pulley and stairs or like items requied during the execution as per site condition, mathematical model studies, protection of civil & mechanical units from flood & silt providing rough filter media etc.

1

-

-

... More
Providing form work with steel plated 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring,shuttering,strutting and propping etc. with wooden battens and ballies height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for insitu-reinforced concrete and plain.

-

-

-

... More
Vertical surfaces such as walls(any thickness) partitions and the like including attached pilasters, buttresses, plinth and string courses and the like complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.

353.84

-

-

... More
Flat surfaces such as soffits of suspended floors, roofs, landings and the like floors etc. upto 200mm in thickness as per direction and to the entire satisfaction of the Engineer-in-charge.

78.47

-

-

... More
Beams, cantilevers, girders and lintels such as soffits of beams, beam haunching, cantilevers girder, bressumers and lintels not exceeding one metre in depth.

58.64

-

-

... More
Edges of slab and breaks in floors and walls under 20 cm wide in all leads and lifts.

41.2

-

-

... More
Sloping portion where inclination is more than 30o complete in all leads and lifts.

673.99

-

-

... More
Providing in RCC work smooth finishing of the exposed surface with cement mortar 1:3 (1cement:3sand) in all leads and lifts.

996.56

-

-

... More
Steel work welded in built up sections, trusses, and framed work including cutting ,hoisting, fixing in position and applying a priming coat of red lead paint in grating, framed guards bars, Ladders, railings, brackets and similar works as per direction and to the entire satisfaction of the Engineer-in-charge.

823.15

-

-

... More
Providing and laying cement concrete 1:5:10(1cement:5sand:10 graded stone aggregate 40mm nominal size and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts.

59.09

-

-

... More
Providing and fixing angle iron door, window, clerestory window frame manufactured from M.S. angle iron section of 50x50x6mm thickness including hinges Jamb, lock jamb, beed and if required angle thrashold of mild steel angle 50x25mm welded or rigidly fixed by mechanical means, Lugs with split end tails to each jamb including steel but hinges 2.5mm thick with provision for locking arrangement and shock observer as specified and applying a coat of approved steel primer after pretreatment of the surface as directed by Engineer-in-charge.

84.6

-

-

... More
Providing and fixing of 1mm thick M.S. sheet garrage door with frame of 40mmx40mmx6mm angle iron 3.15mm M.S. gusset plate at the junction and corners including all necessary fiting complete including appplying a priming coat ofred lead paint using M.S. agnle 30mmx6mm for diagonal braces complete in all respect.

21.7

-

-

... More
Providing and Fixing wire gauge shutters using GMS wire guage of IS gauge designation 85 G with wire of dia 0.56 mm for doors, windows & clerestory windows including bright finished black enamelled iron hinges with necessary screws.2nd class deodar wood.

16.7

-

-

... More
Cement concrete flooring 1:2:4(1cement:2sand:4graded stone aggregate 20mm nominal size )laid in one layer finished with a floating coat of neat cement in 40mm thick in all leads and lifts.

50.94

-

-

... More
20mm cement plaster in single coat of rough sides of bricks/concrete stone walls for interior plastering upto floor two level including arrises internal rounded angles chamfer and rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:6 (1cement:6sand) in all leads and lifts.

240.75

-

-

... More
Pointing on brick work with cement mortar 1:3 (1cement 3 sand) Raised and cut pointing.

202.84

-

-

... More
6mm cement plaster in ceiling in CM 1:3 (1cement:3sand) in all leads and lifts.

83.93

-

-

... More
Providing plinth protection 50mm thick in cement concrete 1:3:6(1cement:3sand:6graded stone aggregate 20mm nominal size) including finishing of the top surface of concrete smooth in all leads and lifts.

28.65

-

-

... More
Providing under layers for plinth protection of 75mm thick (un consolidated) bed dry brick/stone agg. 40mm nominal size will rammed, consolidated & grouted with fine sand including preparation of ground.

28.65

-

-

... More
Applying priming coat over new steel after and including cleaning the surface by thoroughly brooming oil, dust dirt grease and other foreign matter land papering and knotting ready mixed paint finishing hard primer pink)

51.59

-

-

... More
Painting two coats(excluding priming coat) on new steel and other metal surface with enamel paint, brushing to give an even shade including cleaning of all dirt, dust and other foreign matter sand papering and stopping ready mixed paint other than white.

51.59

-

-

... More
Providing and fixing of M.S. grill of required pattern in wooden frames of windows etc. with M.S. Flat square or round wire with round heads bolts and nuts or by screw plain grill as per direction and to the entire satisfaction of Engineer-in-charge.

63.24

-

-

... More
Half brick masonary in common burnt clay buildign bricks in cement mortar 1:4(1cement:4sand) using second class bricks in super sturcture.

23.69

-

-

... More
Boulder filling under floor in all leads and lifts.

16.71

-

-

... More
Finishing wall with water proofing cement paint of approved brand and manufacture & of required shade on decorated wall urfces (two coats) to given an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powered materials.

202.84

-

-

... More
Laying,jointing and trenches GMS tube lightclass of following dia including tube fitting complete (earth work to be measured and paid for separately including testing of joints, within all leads and lifts as per the entire satisfaction of the Engineer-in-charge (Labour rate)

-

-

-

... More
250mm dia

10

-

-

... More
Providing and fixing C.I. Sluice valves Leader/Kirloskar/Sachdeva/LP/Kartar or any other approved make of following diameter with hand wheel as per IS:14846-2000 (Class PN-1.0) (including brass spindle as per 2906-1984 complete with bolts nuts, rubber insertion etc. and as per direction and to the entire satisfaction of the Engineer-in-charge.

-

-

-

... More
50mm dia

1

-

-

... More
200mm dia

2

-

-

... More
Providing and fixing C.I. Sluice valves Leader/Kirloskar/Sachdeva/LP/Kartar or any other approved make of following diameter with hand wheel as per IS:14846-2000 (Class PN-1.0) (including brass spindle as per 2906-1984 complete with bolts nuts, rubber insertion etc. and as per direction and to the entire satisfaction of the Engineer-in-charge.

-

-

-

... More
80mm dia

47

-

-

... More
150mm dia

2

-

-

... More
200mm dia

4

-

-

... More
250mm dia

3

-

-

... More
Construction of chamber for sluice valve, with C I surface box 100 mm top dia. ,160 mm bottom dia &180mm deep (inside) with chained lid RCC top 1:2:4 mix (1cement:2sand:4 graded stone aggregate 20mm nominal size ) 100mm thick foundation concrete 1:5:10 (1cement:5sand:10 graded stone aggregate 40mm nominal size) & inside plastering with cement mortor 1:3 (1cement:3 sand) finished with a floating coat of neat cement i/c curing complete 600x600x750mm inside size With 150mm thick walls of RCC 1:2:4 (1cement:2sand:4 graded stone aggregate 20mm nominal size ) complete with form work &reinforcement with 6mm bar not exceeding 150mm centre to centre both ways

2

-

-

... More
Rising main

-

-

-

... More
Providing laying and jointing and testing in trenches of GMSERW 95% butt welding and 5% MS flange of below mentioned diametre including cost of bends of all degrees conforming to IS 3183-2007 of following steel grade as per dimension rates and test pressure mentioned below in random lenth 5 to 7 Mtrs by considering minimum three layer to make the joints leak proof and to the enitire satisfaction of the Engineer-in-charge. The laying of pipe should be confirmed to IS 5822-1994 (earth work in trenches and butt welding to be measured and paid for separtely) The pipe shall be zinc coated on innter to outer face as per IS:4736-1986 with upto date ammendments.

-

-

-

... More
GMSERW Pipe 300 mm dia of Grade L-210 or AWith W.T. 4.80 mm (RD 0-30) =30 Rmt (Booster stage)

30

-

-

... More
GMSERW Pipe 300 mm dia of Grade L-210 or AWith W.T. 4.80 mm (RD 0-300) =300 Rmt (1st stage)

300

-

-

... More
Providing welding and fixing of MS flanges @ 5% of joints and Butt weld @ 95% conforming to following tables as per IS 6392-1971 (Latest with upto date amendments) and welding of MS flanges with GMSERW pipes in three layers on both faces i.e two layer on outer faces and one layer on inner face to make the joint leak proof (The cost of laying of GMS pipes to be measured and paid for separately). The welding of flanges should conform to IS 816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364. the thickness of gasket not less than 3.00 mm conforming to IS 2712-1998. The work shall be done as per entire satisfaction of engineer in charge within all leads and lifts.

-

-

-

... More
M.S. Flange 300mm dia RD 0-30 Rmt Table-5 (Booster stage)

1

-

-

... More
M.S. Flange 300mm dia RD 0-300 Rmt Table-5 (1st stage)

10

-

-

... More
Providing Circumferencial Butt welded joints by electrical arc welding to below mentioned dia and wall thickness GI pipe welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani Oerlikon (Adore)-CITOJET/ESAB make, conforming to IS 814-1991 including Die pentration test, at site of work complete in all respects, including manual/machanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer in charge.

-

-

-

... More
GMSERW Pipe 300 mm dia of Grade L-210 or AWith W.T. 4.80 mm (RD 0-30) =30 Rmt (Booster stage)

4

-

-

... More
GMSERW Pipe 300 mm dia of Grade L-210 or AWith W.T. 4.80 mm (RD 0-300) =300 Rmt (1st stage)

40

-

-

... More
Providing and fixing of double flanged Cast steel Non return valves of 300mm dia Leader/Kirloskar/RG/Kartar or any otehr approved make for rising main withs tanding the normal seat pressure as per BS:1868/API-600 with upto date ammendments including total head nuts and bolts as per direction and to the entire satisfaction of the Engineer-in-charge.

3

-

-

... More
Fabrication, Providing and fixing of MS screen for supply of cleanwater in distribution of 200mm dia.

2

-

-

... More
Booster Stage-I :Pumping Machinery

-

-

-

... More
Supply of submersible pumping set of KSB/Calama/Kirloskar/Hindustan/Johnstone/ Lubi make comprising to latest relevant BIS Code. The pump should be fitted with C.I impeller of suitable alloys as per IS 8034-1976 latest suitable for Raw water having greased packed bearings and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) of required HP, RPM 2900 of conforming to BIS 9238-1979 latest with upto date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guards, erection clamps , cable clips and depth gauge etc. and suitable for operation on data given below:-

2

-

-

... More
SITE CONDITIONS:-

-

-

-

... More
Location of site:-

-

-

-

... More
The altitude of place in which the motor is intended to work in ordinary service.- 450 mtrs.

-

-

-

... More
Humidity:- Humid during rainy season

-

-

-

... More
Nature of atmosphere:- Normal

-

-

-

... More
Detail of quality of water:- Raw Water

-

-

-

... More
Water free from sand or not:- Free from sand

-

-

-

... More
Water corrosive or not:- Not corrosive

-

-

-

... More
Turbidity:- 100 ppm

-

-

-

... More
Type of well:- Sump well

-

-

-

... More
Inside dia of well:- meter dia.

-

-

-

... More
Depth of water during HFL in the well:-

-

-

-

... More
Maximum draw down:- mtrs.

-

-

-

... More
Depth of well :- 10.00 mtrs.

-

-

-

... More
Any other information if required.

-

-

-

... More
OPERATING CONDITIONS

-

-

-

... More
Type of current:- AC. Three phase

-

-

-

... More
Operating frequency 50 Hz.

-

-

-

... More
Rated voltage 400(+/-) 10% volts.

-

-

-

... More
System of earthing if any to be adopted Double loop earthing as per BIS: 3243-1987 latest with upto date amendments .

-

-

-

... More
Speed of revolutionTo be quoted by tenderer

-

-

-

... More
Direction of rotation To be quoted by tenderer .

-

-

-

... More
No. of working hours per day. 20 hours

-

-

-

... More
The maximum temperature of cooling air and water in the place in which the pump set is intended to work in ordinary service Temperature of place to be specified 20oC to 42oC.

-

-

-

... More
MOTOR

-

-

-

... More
Ref. to BIS code BIS 9283-1979 with upto date amendments

-

-

-

... More
Type of enclosure of motor. As per BIS-4691-1985 (Latest)

-

-

-

... More
Type of duty : Continuous

-

-

-

... More
Mechanical output in KW Suitable for driving submersible pumps required for duties specified against pumps. To avoid over loading of motor a margin of about 15-20% may be kept in the rated output to prime Mover.

-

-

-

... More
Class of insulation Class –B

-

-

-

... More
Max. Permissible temp. Rise of motor reqd. if different from that given in 8 (viii) above.To be specified by the tenderer.

-

-

-

... More
Particulars of test reqd. & where they are to be conducted. AS per terms and conditions attached.

-

-

-

... More
Particulars as to whether voltage limiting device will be employed. Shunt capacitor is also proposed to be installed for improving the power factor at site.

-

-

-

... More
Type of motor Star Delta strater up to 37.5 KW As per BIS 9283-1979 or latest.

-

-

-

... More
Details of shaft extension required

-

-

-

... More
Break way torque in terms of rated load torque and the corresponding break-way starting current which may be taken from the supply with the starting apparatus in circuit should not exceed 2.5 times of the full load current .

-

-

-

... More
Nature of load and any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelerated and No. of starts during a specified period.

-

-

-

... More
Where possible fault capacity of the system to which the motor is connected.The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations.

-

-

-

... More
PUMPS

-

-

-

... More
Nos. of pumps required. 2 No. pumps (Both will run simultaneously)

-

-

-

... More
Spare parts required. For two years normal maintenance as recommended by manufacturer.

-

-

-

... More
Type of drive. Electric induction motor.

-

-

-

... More
Optional fittings required

-

-

-

... More
Pump Operating conditions

-

-

-

... More
Capacity 32.48 LPS for each Pump

-

-

-

... More
Total head in meters 14.84 meter

-

-

-

... More
Static head meters

-

-

-

... More
Minimum depth of water Meters

-

-

-

... More
Variation in water level meter

-

-

-

... More
Ground level to Max. water level meter

-

-

-

... More
Ground level to delivery point Meter

-

-

-

... More
Pressure in the suction tank.

-

-

-

... More
Pressure in the delivery tank

-

-

-

... More
Length of rising main 30 meters

-

-

-

... More
Dia of rising main 300 mm dia

-

-

-

... More
Turbidity of water 100 PPM

-

-

-

... More
Drive type Electric driven

-

-

-

... More
Limits of total head in which the pump is required to operate. (-) 15% to (+) 10% of total head

-

-

-

... More
Suction/Delivery size of pump

-

-

-

... More
Efficiency of pump at

-

-

-

... More
a)     Duty head

-

-

-

... More
b)     (+) 10% head.

-

-

-

... More
c)      (-) 15% head.

-

-

-

... More
Material of construction. To be specified by the tenderer (manufacturers certificate to be appended)

-

-

-

... More
Supply of suitable starter of conforming to BIS 8544-1987 (P-II)latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filing of suitable capaity.

2

-

-

... More
Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of pannel board shall be subject to approval of Engineer-in-Charge

1

-

-

... More
Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of suitable capacity for above motor with selector switches conforming to BIS-1248-1983 latest with upto date amendments.

2

-

-

... More
Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of 0-500 Volts range for above motor with selector switches conforming to BIS-1248-1983 latest with upto date amendments.

1

-

-

... More
ICTP switches with HRC fuses of Havells/L&T/standard /cromption make for required motor of suitable capacity and conforming to BIS: 4064-1978 latest with upto date amendments.

2

-

-

... More
Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutral conforming to BIS: 8084 –1976 and 11353-1985 read with 5578-1985 all latest with upto date amendmentsof suitable rating.

1

-

-

... More
MCB of suitable capacity of Havells/standard/MDS/Jyoti/Kilburn make to feed motors offered by the tenderer conforming to BIS: 2516-1985 latest with upto date amendments with neutral linked under voltage release.

1

-

-

... More
3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS-3452 part-I & II latest with upto date ammendments. 15 Watt.

1

-

-

... More
50 mm dial Hour run meter of CEE/NEE make of suitable range as per relevant BIS specifications.

1

-

-

... More
Supply of Leader/Kirloskar/Sachdeva/LP/Kartar or any other approved make . cast iron (class PN. 1.0 ) double flanged sluice valve having size one dia higher than delivery of pump and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :780-1984 (Part I)

2

-

-

... More
Supply of Leader/Kirloskar/Sachdeva/LP/Kartar or any other approved make cast iron (class PN. 1.0 ) double flanged ( swing check type) reflux valve having bye pass arrangement and having one dia higher than delivery of pump and capable of withstanding nominal seat pressure of 10.20 kg/cm2 as per BIS-5312-1984.(Part-I).

2

-

-

... More
Supply of Leader/Kirloskar/Sachdeva/LP/Kartar or any other approved make 300 mm dia. cast iron class PN. 10 double flanged (swing check type) reflux valve having bye pass arrangement and size equal to dia of rising i.e. 300 mm for withstanding nominal seat pressure of 10.20 Kg/Cm 2 as per BIS 5312-1984 (Part-I )

1

-

-

... More
Supply of PVC joint less flat water proof cable as per BIS: 694-1990 latest with upto date amendments suitable for the pump sets offered from MCB to motor including all other electrical equipment/accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced by tender.

1

-

-

... More
Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of required capacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and other electrical equipment’s.

1

-

-

... More
Supply of standard make circular dial pressure gauge 0-11 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to BIS: 3624-1987 latest with upto date amendments.

2

-

-

... More
Providing and laying delivery pipe 150 mm dia. and common header 300 mm dia GMSERW pipes (IS:3183-2007) jointed with MS flanges of table-5 as per IS: 6392-1971 (upto a length of 20 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses as per layout drawings approved by Engineer-in-Charge.

1

-

-

... More
Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments Baja/L&T/Asian/cromption make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to BIS –4064-1978 or latest with HRC fuses (range to be specified by the tendrerer).

2

-

-

... More
Supply of suitable cable for water level guard

1

-

-

... More
Supply of supporting clamps.

1

-

-

... More
Supply of cable clips of required size.

1

-

-

... More
Erection of all equipment including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.

1

-

-

... More
1st stage

-

-

-

... More
Providing horizontal spindle horizontal split casing/end suctions (back full out arrangement) single/double/ multistage centrifugal pump or combination of pump in series of recommended make such as Mather & Platt/KSB/Kirloskar as per BIS-1520-1980 with up to date amendments, read with IS: 9137-1978 or latest edition suitable for lifting clear water for under mentioned characteristics with CI impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a MS/Cast steel base plate ( base plate to be from the manufacturers of the pumping unit only) to Squirrel Cage drip proof induction motor required HP with 2900 RPM such as Kirloskar and suitable for operation on 400 (+)/-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be at least 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 15% of the duty point head. The motor should be as per IS: 325-1978 with up to date amendments. read with IS: 900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:-

2

-

-

... More
Discahrge (Q) : -Total 32.48 LPS (Each Pump)

-

-

-

... More
Or Cum/Hour

-

-

-

... More
Total dynamic head : 39.57 Mtr

-

-

-

... More
(a) LWL in sump well (h) : 511.73 mtr

-

-

-

... More
(b) Shaft level : 510.23 Mtr

-

-

-

... More
(c ) Level at discahrge point : 544.30 mtr

-

-

-

... More
(d) Suction lift :- 0.00 mtrs

-

-

-

... More
(e) Residual head : 0.00 Mtr

-

-

-

... More
(f) Static head : 34.07 mtrs

-

-

-

... More
(i) Rising Main :

-

-

-

... More
(a) Length 300 Mtr

-

-

-

... More
(b) Dia. : 300 mm

-

-

-

... More
(iv) Pumping Hours : 20 Hours

-

-

-

... More
(v) Altitude of installation above MSL :

-

-

-

... More
(vi) Characteristics of water :

-

-

-

... More
(a) Temperature : 20.00 0 C

-

-

-

... More
(b) Ambient temperature 42.00 0 C

-

-

-

... More
(c ) Turbidity 50.00 NTU

-

-

-

... More
(d) Alkalinity than Mg/Ca Co3

-

-

-

... More
(e) Size of the solids mm

-

-

-

... More
(f) Other

-

-

-

... More
Providing ICTP Main Switch with HRC fuses/Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064-1978 with up to date amendments immediately after the power meter of HPSEB

1

-

-

... More
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-

1

-

-

... More
O.C.B. Havell/MDS/Standard of make of suitbale capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516-1985 with up to date amendments with.

1

-

-

... More
E.L.R. of Havell/MDS/INDETEC make as per IS: 2516-1977 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.

1

-

-

... More
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 3842 ( Latest edition).

1

-

-

... More
100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064-1978 with up to date amendments.

1

-

-

... More
Power factor meter of AE/L&T Rishab make as per relevant IS codes with up to date amendments of suitable rating.

1

-

-

... More
Frequency meter of AE/ L&T Rishab make as per relevant IS: Codes with up to date amendments of suitable rating.

1

-

-

... More
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11353-1985 read with BIS 5578-1985 with up to date amendments 63 Amp.

1

-

-

... More
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064-1978 with up to date amendments.

2

-

-

... More
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I&II) with up to date amendments.

1

-

-

... More
100mm Square type AC supply Ammeter of AE /L&T Rishab make of suitable range with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments.

2

-

-

... More
Capacitor of L&T/Bajaj/Assian/Crompton make as per IS:2834-1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of required rating according to HP offered including cables as per relevant ISI code ( of Siemens/Glocter/IEC make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064-1978 with upto date amendments

2

-

-

... More
Supply of fully automatic air breaker Star delta starter of MEI make suitable for required HP motor as per IS: 8544 (Part-II)1989 including all accessories.

2

-

-

... More
Providing Hour run meter of recommended make of suitable capacity as per IS: 722 (Latest edition)

1

-

-

... More
Providing double flanged Cast iron sluice valve of Leader/Kirloskar/LP/Kartar or any other approved make of 200mm dia for the suction pipe and capable of withstanding the normal seat pressure 10.20 Kg/cm2 as per IS: 780-1984 Class 1.0 with up to date amendments.

2

-

-

... More
Providing double flanged Cast iron sluice valve of Leader/Kirloskar/LP/Kartar or any other approved make of one dia higher than pump for the delivery pipe and capable of withstanding the normal seat pressure 10.20 Kg/cm2 as per IS: 780-1984 Class PN 1.0 with up to date amendments.

2

-

-

... More
Providing double flanged (Swing type) Cast Iron reflux valve of Leader/Kirloskar/LP/Kartar or any other approved make and one dia higher than pump having bye pass arrangement on the delivery line of pump and capable of with standing normal seat pressure 10.20 Kg/cm2 as per IS: 5310-1984 Class 1.0 with up to date amendments.

2

-

-

... More
Providing double flanged Cast Iron non return valve of Leader/Kirloskar/LP/Kartar or any other approved make and of 200 mm dia having bye pass arrangement for rising main and capable of with standing normal withstanding the normal seat pressure 10.20 Kg/cm2 as per IS: 5312-1984 Class PN1.0 with up to date amendments.

1

-

-

... More
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0-11 Kg/cm2

2

-

-

... More
Installation of all the items operating at S.No.63 to 70 as per the systematic drawing

1

-

-

... More
Providing and fixing double flanged GMSERW piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.G.M.S.TUBE Conforming to IS: 1239 – 1979 ( part – I) (Heavy class) flanged with M.S. flanges of in delivery side & common header.(Pipe would be given by department free of cost)

1

-

-

... More
The size of the various components to be as under:-

-

-

-

... More
(i) Suction pipe 200 mm dia flanged with Table-5 = 10 Rmt

-

-

-

... More
(ii) Delivery pipe 150 mm dia flanged with Table-5 = 5 Rmt

-

-

-

... More
(iii) Common Header 300 mm dia flanged with Table-5 = 10 Rmt

-

-

-

... More
And will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.

-

-

-

... More
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/GICO/Grandly /National make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.

1

-

-

... More
Motor side: suitable size

-

-

-

... More
Supply side: suitable size

-

-

-

... More
Providing and fixing double loop earthing and G.I. plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx6mm G.I. strips & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.

1

-

-

... More
Distribution system

-

-

-

... More
Laying and jointing of HDPE pipes of various dia meter in trenches confirming to IS: 4984-1972 (PN 4 PE-80 grade) complete with all type fittings and accessories i.e. coupling, Tees, Bends, reducers, Screwed adapters, flanged tail pieces etc (earth work to be measured and paid for separatey) within all leads and lifts. (Labour Rate)

-

-

-

... More
110mm dia

286

-

-

... More
140mm dia

440

-

-

... More
160mm dia

1920

-

-

... More
180mm dia

418

-

-

... More
200mm dia

1056

-

-

... More
225mm dia

1865

-

-

... More
250mm dia

1034

-

-

... More
280mm dia

1056

-

-

... More
Providing and fixing of Tees and reducers with flanges of PN 4.0 PE 80 in all leads and lifts.

47

-

-

... More
Fitting and accessories)

-

-

-

... More
Laying and jointing of HDPE pipes of 90mm dia meter in trenches confirming to IS: 4984-1972 (PN 4.00 PE-80 grade) complete with all type fittings and accessories i.e. coupling, Tees, Bends, reducers, Screwed adapters, flanged tail pieces etc (earth work to be measured and paid for separatey) within all leads and lifts. (Labour Rate)

117.5

-

-

... More
Providing and fixing of 90mm dia HDPE PN-6 end in all leads and lifts

94

-

-

... More
Providing and fixing of 90mm dia HDPE PN-6 bend all degree in all leads and lifts

94

-

-

... More
Providing and fixing of 90mm dia HDPE pipe PN-6 OC Pump connector in all leads and lifts

47

-

-

... More
Providing,laying and jointing 350mm dia RCC pipe NP2 of 0.65m length with 1 hole in all leads and lifts.

30.55

-

-

... More
Providing,laying and jointing 900mm dia RCC pipe NP2 of 1.25m length with 1 hole in all leads and lifts.

58.75

-

-

... More
Providing and fixing of M.S. sheet locking arrangement for potecting the outlets complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.

188

-

-

... More
Providing & Installation of Automation system at pumping station consisting fully wired panel as per installed equipments with PLC System having board Ethernet connectivity of ALLEN Bradly/ SBEM and George fisher make compatible to SCADA and comprised with GPRS modem for wireless internet connectivity ,HMI system, CPU (Core i7 processer, 500 GB Hard Disk & 4GB RAM ) with TFT 21" monitor and other accessories such as connecting cables, cable tray, switches etc. required as per site condition.

-

-

-

... More
Providing & Installation of Automation system at pumping station consisting fully wired panel as per installed equipments with Micro PLC/ RTU System having board Ethernet connectivity of ALLEN Bradly/ SBEM and George fisher make compatible to SCADA and comprised with GPRS modem for wireless internet connectivity and other accessories such as connecting cables, cable tray, switches etc. required as per site condition.

-

-

-

... More
Providing Automation system complete for Intake Booster Stage Pump House

-

-

-

... More
Providing installation of SCADA software system having minimum 75 tags and scalable to unlimited tags with inbuilt Historian/ SQL Data base for various parameter of Allen Bradly/ SBEM/ George Fisher/Dynemics or standard approved brand for main controlling stations complete in all repect to the entrie satisfaction of Engineer- in- charge.

-

-

-

... More
Providing and installation of SCADA Software system at Booster stage pump house Dobber complete in all respect.

1

-

-

... More
Providing and installation of SCADA Software system at 1st stage pump house Rail complete in all respect.

1

-

-

... More
Providing and fixing high low level switches/level transmeter of standard approved brand such as ABB etc. for P/ Well(1 no.) & sumpwells(4 No.)

5

-

-

... More
Providing and fixing of pressure transmetre (PT) range 0-500 mtr.. Head along with display compatible to SCADA system of standard approved make for rising mains

-

-

-

... More
Near LIS Rail Ist Stage Pump House

1

-

-

... More
Providing and fixing of clear water electrinic/ Magnectic flow metre compatible to SCADA system and head upto 500 mtr. along with display and other required accessories of size complete in all respect.

-

-

-

... More
P/F of electromagnetic flow metre 300mm dia. complete in all respect

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.