Himachal Pradesh Irrigation And Public Health Department Tender
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date13 Mar 2024
Closing Date22 Mar 2024
Tender Amount₹ 33,15,922
Costs
EMD
₹ 66,350Document Cost
₹ 400Tender Fee
Refer Documents
Summary
C/o Lis Gadda Bhuddi And 2 Nos Medium Height Multipurpose Check Dam On Markanda River Tehsil Nahan Distt Sirmour Hp
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HPIPH_88388_1Bid Award Id
ViewTender No
NHN-SMROO-722- 17501-560 dt 12-03-24Tender Authority
Himachal Pradesh Irrigation And Public Health Department ViewPurchaser Address
-Website
http://http://hpiph.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Squared rubble masonary coursed with hard stone of approved quality in foundation and plinth including racking out joints in cement mortar 1:6(1cement:6app.sand)including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
26.36
-
-
Providing and laying reinforced cement concrete work 1:2:4(1cement:2app.sand:4app.graded stone aggregate 20 mm nominal size) nominal size and curing complete excluding cost of form work and reinforcement for RCC work in suspended floors roofs, landings shelves and their supports balconies beams,girders bressumers and cantilevers upto floor two level in all height and depth, including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
2.3
-
-
Providing and laying cement concrete 1:2:4 (1cement:2 sand:4app.graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work in walls including attached buttresses, pilaster of their caps & bases and their caps and bases and string courses etc upto floor two level in all height and depth. including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
36.69
-
-
Providing and fixing M.S Plate for V-Notch 90 Degree complete in all respect including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge..
2
-
-
Fabrication,Providing and fixing of MS Screen for supply of clean water in distribution complete in all respect including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge..
2
-
-
Providing and laying cement concrete 1:1.5:3 (1cement:1.50 sand:3app.graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work in walls including attached buttresses, pilaster of their caps & bases and their caps and bases and string courses etc upto floor two level in all height and depth. including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
20.41
-
-
Providing Tor Steel reinforcement for RCC work including banding, binding and placing in polsition complete upto floor two lelvel including all leads, and carriage ofmaterial at site and as directed by the Engineer Incharge.including cost of binding including all leads ,lifts and carrige of material at site and as directed the Engineer Incharge.
34.04
-
-
Providing and laying cement concrete 1:5:10 (1cement:5pp.sand:10app.graded stone aggregate 40mm nominal size) with and curing complete excluding cost of form work in retaining walls/breast walls, the size of plums shall usually be 150mm. To 300mm. As per H.P.P.W.D. specification. including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
37.17
-
-
Providing form work with steel plates 3.15 mm thick with angle iron in frame 30*30* 5 mm so as give a rough finished including centring ,shuttring , strutting and proping etc. height or proping etc. height or proping and centring below supporting floor to celling not exceeding 4 mtrs and removal of the same for insitu reinforced concrete and plain concrete work in ,including all leads ,lifts and carrige of material at site and as directed the Engineer Incharge.
-
-
-
vertical surface such as walls (any thickness) partition and the like I/c attached pillasters, buttresses, plinth and string sourses and the lick
298.66
-
-
Providing weep hole in brick/ stone masonary plain/ reinforced concrete abatment wing wall returns wall both 100mm dia PVC pipe extended htrough the full width of the structure with slop of vertical and horizontal towards drawing and complete in all leads, lifts and material.
18
-
-
Bolder filling dry hand packed tightely as in wire crate apron bounds (wire crate to be measured and paid separtely) including all leads and lifts and carriage of material
59.4
-
-
Wire crate made of GI Wire filled with boulders with square cut faces against the wire ( wire is to be measured & paid for separately)
29.63
-
-
Wire crate made of GI Wire filled with boulders with square cut faces against the wire ( Boulder filling is to be measured & paid for separately) GI Wire 4.00 mm thick SWG 6.00 15x15 cms.mesh
145.83
-
-
Brick work using common burnt clay building bricks (2nd class) including racking out joints in cement mortar 1:6(1cement :6sand)foundation and plinth including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
12.84
-
-
Applying coat of hot bitumen(mexphlat 80/100 or equipment using 1.70Kg per square metre on damp proof, course after cleaning the surface with a cloth lightly socked in Kerosine oil, including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
2.58
-
-
Brick work using common burnt clay building bricks (2nd class) including racking out joints in cement mortar 1:6 (1cement :6sand)extra for super structure above plinth level and upto floor two level including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
16.64
-
-
20mm cement plaster in single coat on rough side of brick /stone masonary for interior plastering upto floor two level including arrises, internal rounded angles,chamfers and/or rounded angles not exceeding 80-mm in girth and finished even and smooth in cement mortar 1:6 (1cement:6sand) including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
31.92
-
-
15mm cement plaster in single coat on rough side of brick /stone masonary for interior plastering upto floor two level including arrises, internal rounded angles,chamfers and/or rounded angles not exceeding 80-mm in girth and finished even and smooth in cement mortar 1:6 (1cement:6sand) including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
97.14
-
-
15mm cement plaster in single coat on Fair side of brick /stone masonary for interior plastering upto floor two level including arrises, internal rounded angles,chamfers and/or rounded angles not exceeding 80-mm in girth and finished even and smooth in cement mortar 1:6 (1cement:6sand) including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
78.6
-
-
40 mm thick Cement concrete flooring1:2:4(1cement: 2app .sand:4app.graded stone aggregate 20 mm nominal size) laid in one layer finished with floating coat of neat cement thick including all lead, lifts and arriage of material at site and as the Engineer Incharge.
23.55
-
-
Supplying and fixing cast iron cover with frames for man holes of size 500mm intenal dia metre C.I. Cover (Medium) duty the weight of cover to be not less than 116Kg I/c all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
2
-
-
Supplying and fixing Channel ISMC 200 for hosting Chain Pulley i.e Chain Pully arrangement all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
9.41
-
-
Providing and fixing pressed steel door frames confirming to manufacturing from commercial mild steel of 1.25mm thickness , including hings, jamb, lock jamb, bead and 50x25 mm, or base ties of 1.25 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with moetar guards, lock strike plate and shock absorbes as specified and applying a cost of approved steel primer after pre-treatment of th esurface as directed by the Engineer Incharge.Profile-A
7
-
-
Providing and fixing 1mm thick M.S. sheet garrage door with frame of (40x40x6mm) angle iron 3.15 mm M.S. gussest plates at the junctions and corner all necessary fittings complete including applying a priming coat of red lead paint, including all leads, lifts and carriag of material at site and as directed by the Engineer Incharge. (using FLAT 30MM X 6MM for diagonal braces and control cross/pieces).
11.54
-
-
Providing and fixing Steel Ladder of 40mm diameter pipes complete.I/c all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
140.74
-
-
Providing form work of ordinary timber so as give a rough finish including centring, shuttering , strutting and propping etc. ht of propping and centring below supporting floor to celing not exceeding 4 mtrs and removal of the same for insitu-reinforced concrete and plain concrete work in Arches upto 6 mtr span, including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
-
-
-
vertical surface such as walls (any thickness) partition and the like I/c attached pillasters, buttresses, plinth and string sourses and the lick
54
-
-
B) Flat surfaces such as soffits of suspended floors, roofs and landing etc. floors upto 200 mm in thickness.
43.48
-
-
Providing plinth protection 50mm in cement concrete 1:3:6 (1cement:3app. sand: 6app. graded stone aggregate 20mm nominal size) including finishing the top surface of concrete smooth including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
8.81
-
-
Providing and fixing M.S handles with necessary screw etc.(125mm) complete including all lead lifts and cariirage of material at site and as directed by the Engineer Incharge
14
-
-
Providing and fixing M.S Tower Bolt (Barrel type)with necessary screw etc.(200x10mm) complete including all lead lifts and cariirage of material at site and as directed by the Engineer Incharge
11
-
-
Providing and fixing sliding door Bolt ,with necessary screw etc.(250x16mm) complete including all lead lifts and cariirage of material at site and as directed by the Engineer Incharge
3
-
-
P/F on wall face cast iron water pipe 100mm dia including fitting and joints with spun year and cement mortar 1:2 (1cemernt : 2sand ) , including all leads, lifts and carriag of material at site and as directed by the Engineer Incharge.
23
-
-
White washing with lime on undecorated wall surfaces(two coats) to give an even shade including thoroughly brooming the surface to remove all dirt, dust mortar dirt and other foreign matter.including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
156.06
-
-
Steel work welded in built up sections , trusses and framed work including cutting, hoisting, fixing in position and applying and priming coat of red lead paint in gratings, framed guard bars, ladders, railings , brackets and similar work. including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
58.28
-
-
Applying priming coat over new metal and metal based surfaces after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter sand papering and knotting: ready mixed paint brushing wood primer pink,including all leads, leads, and carriage of material at site and as directed by the Engineer Incharge.
58.32
-
-
Painting one coat (excluding priming coat) on new steel and steel based surfaces with ready mixed paint brushing to give an even shade including cleaning of all dirt and dust and other foreign matter sand papering and knotting ready mixed paint other than white.
69.86
-
-
Manufacturing and Supplying of fencing panel of size 1.20mx1.80m of Jali 25X25mm welded to M.S.black tube of 32mm dia of 3mm thick with M.S Flats 20X3mm, including cutting welding, painting with red oxide paint complete in all respects the jali of 25x25mm should be fixed in 1.20x1.20m. the work should be executed as per the entire satisfaction of the Engineer In charge . It include all leads, lifts and carriage of material as per the direction of the Engineer Incharge.
27
-
-
Providing and fixing MS fan clamp type-I of 16 mm diaM.S Bar bent to shape with hooked ends in RCC during laying including printing the exposed portion of loop,all as per standard design complete etc. inclduing all leads, lifts and carriage of material at site
and as directed by the Engineer incharge.
2
-
-
Providing and fixing MS grills of required pattern in wooden frames/pressed ,steel frame with MS flat square/round bars 12mm dia with round headed bolts and nuts or by screws. Plain Grill, including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
35.77
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box
and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..
24
-
-
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as
required.
30
-
-
Wiring for circuit wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2X 1.5 sq. mm + 1 X 6 sq. mm earth wire
40
-
-
Wiring for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2X 1.5 sq. mm + 1 X 6 sq. mm earth wire
12
-
-
Supplying and fixing metal box of 180x100x60mm sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
2
-
-
Supplying and fixing PVC batten/ angle holder including connection etc. As required.
6
-
-
Providing Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
2
-
-
Providing and fixing LED tube set 36 watt (Osram make) complete in all respect including of all leads, lifts and carriage of material at site and as directed by the Engineer-Incharge.
2
-
-
S/F 40Amp to 63 Amp rating 240 volt. L-.series monitor circuit breaker of following pole MCB/DB comp.with connections testing and commissioning etc. as required Category -B 63 amper double pole (Anchor and Havells make) complete in all respect including of all leads, lifts and carriage of material at site and as directed by the Engineer-Incharge.
2
-
-
Supply and fixing of Two way single pole and natural sheet steel MCB distribution board 240 volts on surface/recessed complete with tinned copper bus bar natiral link earth bear dinber detachable gland plate inter connection including paining earthing etc. as required .Bus bar 10 way complete in all respect including of all leads, lifts and carriage of material at site and as directed by the Engineer-Incharge.
2
-
-
S/F 5 Amp to 32 Amp rating 240 volt. L-.series monitor circuit breaker of following pole MCB/DB comp.with connections testing and commissioning etc. as required Category -B single pole (Anchor and Havells make) complete in all respect including of all leads, lifts and carriage of material at site and as directed by the Engineer-Incharge.
4
-
-
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
4
-
-
Extra Using salt and charcoal for pipe earth electrode Earthing with including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
-
-
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
24
-
-
P/L testing & commissioning of prewinded LED street light 70 watt , complete with rod & other accessoried suitable to operate on 125 volts phase AC supply directly on surface with copper wiring as required with G.I Pipe bracket complete in all & as directed by the Engineer Incharge. ( Orient make)
2
-
-
Evaluation Notes How It Works ?