Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date23 Sep 2023
Closing Date3 Oct 2023
Tender Amount₹ 85,87,993
Costs
EMD
₹ 1,18,400Document Cost
₹ 800Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_HPIPH_79271_1Bid Award Id
ViewTender No
JHT-BLP003-782 NIT No. 10653-752 dt 23-09-2023Tender Authority
Himachal Pradesh Irrigation And Public Health Department ViewPurchaser Address
-Website
http://http://hpiph.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Excavation infoundation and trenches etc.(including pipes and pits upto all depths) in all kinds of soil such as pick work, jumper work, blasting and chiselling soft or hard rock where blasting is prohibited in all leads and lifts including trimming and dressing of sides, levelling of bed to correct grade stacking the excavated soil clear from the edge of excavation and returning the excavated soil after laying, jointing and testing of pipes in trenches in 15cm layers including consolidating each deposited layers by ramming and watering and then disposing of all surplus excavated soil as directed in all leads and lifts and soring strutting and trimming and dressing where ever required including cost of diversion for traffic night signals fixing caution board, crossing over trenches for access to houses and fencing etc. complete in all respect.
-
-
-
Pick /jumper work 50% each
188.34
-
-
Laying jointing in trenches and testing ( to be leveled to grade) GMS pipe confirming to IS 1239-2001 jointed with 5% of total joints flanged conformimg to IS: 6392-1971 (latest upto date amendements) and remaining joints provided with circumferential butt welded joints by considering minimum three layers and welding of flanges with pipes as per IS: 816-1969 with electrod as per IS: 814-1991 including required number and size of nuts and bolts as per 1369-1967 and compressed asbestos fiber jointing gaskets not less than 3mm in thickness as per IS: 2712-1998. The welding of flnages to be done on both faces in two layers on outer face & one layer on inner face to make the joints leak proof and to the entire satisfaction of the Engineer-in-charge. The laying of pipe shall confirm to IS: 5822-1994 and as per CPHEEO manual. The laying will include all operations such as cutting welding and jointing including flushing cleaning and hydraulic testing complete in all respect to the entire satisfaction of the Engineer-in-charge including entire carriage of materials. Pipe will be measured for straight length only. (Earth work in trenches & Jointing MS flanges and butt welding joints) will be measured and paid for Separately.
-
-
-
Booster stage :- GMS Pipe 100 mm dia ( Medium Class) of wall thickness 4.50 mm flange table 5 from RD 0/0 to 305.
305
-
-
Providing circumferencial Butt welded joints by electrical arc welding to various dias GI pipe medium / heavy class, welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS: 816-1969 specifications, by using welding electrodes of 2.50 mm to 6.30 mm of Advani , Oerlikon (Adore)-CITOJET/ESAB make conforming to IS:814-1991, at site of work complete in all respects, including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
-
-
-
GI pipe 100 mm dia
48
-
-
Providing and welding M.S. flanges at suitable points conforming to following tables as per IS 6392-1971 (Latest with upto date amendments) with plain end GMS/GMSERW pipe in requsite ( minimum three) number of layers on both faces (Two outer and one inner ) to make the joint leak proof. The welding of flanges should confirm to IS:816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1369-1967 including cost of gasket sheet, nuts & bolts. The thickness of gasket sheet not less then 3.00 mm confirming to IS 2712-1998. The work shall be done to the entire satisfaction of engineer in charge with in all leads and lifts.
-
-
-
100 mm dia flange table 17 from RD 0/0 to 305
3
-
-
Providing/Installation, erection, testing and commissioning of star rated energy efficient Mono Submersible pumping set of KSB/Calama/ Johnsion/ Crompton/SABAR/ Oswal/ Kirloskar make conforming to latest relevant BIS Code . The pump should be fitted with impeller of suitable alloys suitable for handling Raw water (Turbidity-150 PPM) having greased packed bearings and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) of required HP & 2900 RPM or as per manufacturer's specifications of reputed make confirming to BIS 9283-1979 latest with upto date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guards, erection clamps , cable clips, depth gauge NRV & Sluice valves of approved class etc. The work should be completed to the entire satisfaction of the Engineer-in – Charge. (2 No. Pumping set submersible type complete including allied accessories)
2
-
-
Discharge:- 8.72 LPS per set, Total dynamic head :- 32.85 metre, Static head:- 21.00 metre, Dia of Rising Main:- 100 mm , Length of Rising Main:- 305 Rmt, Pumping Hours:-16 hours, Coupling and base plate :- 2 sets, Turbidity :- upto 150 PPM, Temprature 20 degree to 45 degree centigrade.Limits of total head :- (-) 15% to (+) 10%
-
-
-
Providing and Installation of suitable direct on line of MEI/Kilburn make starter confirming to BIS 8544 -1979 latest with upto date amendments for electric motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release with initial oil filing of suitable capacity.
2
-
-
Providing ICTP Main Switch with HRC fuses / side handled operated change over switch of L&T / crompton/ standards/ Havells make of suitable capacity operational rating as per IS 4064(part II) 1978 with up to date amendments)
1
-
-
Providing and fixing double flanged Cast iron sluice valve of Leader/Kirloskar/ KSB make class PN 1.60 of 100 mm dia capable of withstanding the normal seat pressure of 16.32 Kg/cm2 as per IS: 780-1984 with up to date amendments complete in all respects.
1
-
-
Providing and fixing double flanged Cast Iron reflux valve Leader/Kirloskar/ KSB make 100 mm dia class PN 1.60 capable of withstanding the normal seat pressure 16.32 kg/cm2 as per BS: 5312-1984 with up to date amendments .
1
-
-
Providing and laying suitable size copper PVC insulated armoured power 3.0 core cable ( one cable carrying all the three phases) of size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
1
-
-
Motor side: Suitable capacity.
-
-
-
Supply side: Suitable capacity.
-
-
-
Providing and fixing of PVC joint less flat water proof cable as per BIS 694-1990 latest with up to date amendments suitable for the pump sets offered from MCB to motor including all other electrical equipments/ accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities same shall be replaced by the bidder.
1
-
-
Providing and fixing double loop earthing with copper strips & copper plate 600 x600x3 mm thick complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx3mm copper strips, digging of pits & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
1
-
-
Providing and fixing circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0- 11 Kg/cm2
2
-
-
Providing and fixing double flanged GMS piping network for suction and delivery pipes suitable to pumps offered and common header as per the rising main respectively complete with all specials such as rappers, flanges, rubber gaskets minimum 3 mm in thickness as per IS 2712-1979, nuts and bolts as per IS:1364-1983, bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as per drawing up to 5 metre away from the outer wall of pump houses. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated.The size of various components are as under:-
1
-
-
Suction pipe 100 mm dia M.C or as per pump Minimum length= 5 metre.
-
-
-
Delivery pipe 80 mm dia H.C Minimum length= 10 metre
-
-
-
Common header 100 mm dia H.C Minimum length = 10 metre
-
-
-
The GMS tube confirming to IS :- 1239-2004 part-I Medium class flanged with MS flanges of table 17 in suction pipe and heavy class flanged with MS flanges of table 17 in delivery side and common header.
-
-
-