Himachal Pradesh Irrigation And Public Health Department Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender

Works
Pipes and Pipe Related Activities
Eprocure
Opening Date31 Mar 2021
Closing Date6 Apr 2021
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Lis To Horticulture Area Of Bishaldhar, Muhan, Ropa. In Ani Block, District Kullu Hp.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying cement concrete 1:5:10(1cement:5sand:10 graded stone aggregate of 40mm nominal size) with 15% plum and curing complete excluding cost of form work in retaining walls/breast walls, the size of plums shall usually be 150mm to 300mm complete in all respect within all lead and lifts as per the direction of Engineer-in-Charge.

4.22

-

-

... More
Providing and laying cement concrete 1:3:6(1 cement:3 sand:6 graded stone agg. 40mm nominal size) and curing complete excluding cosot of form work and reinforcement of RCC work in foundation and plinth with in all leads and lifts as per direction and to the entire satisfaction of the Engineer-in-charge.

39.89

-

-

... More
Providing and laying cement concrete 1:3:6(1 cement:3 sand:6 graded stone agg. 20mm nominal size) and curing complete excluding cosot of form work and reinforcement of RCC work in foundation and plinth with in all leads and lifts as per direction and to the entire satisfaction of the Engineer-in-charge.

28.55

-

-

... More
Providing and laying cement concrete 1:6:12(1cement: 6sand: 12 graded stone agg.40mm nominal size) and curing complete excluding cost of centering and shuttering including all leads and lifts. a) Foundation and plinth

31.01

-

-

... More
Providing and laying cement conc 1: 1½ :3 (1cement:1:1½ sand :3 graded stone agg. 20mm nominal size) and curing com-plete excludidng cosot of form work and reinforcement for RCC work in foundation and plinth with in all leads and lifts as per direction and to the entire satisfaction of the Engineer-in-charge in:-

-

-

-

... More
Foundation,footing basis of columns & the likeand mass concrete.

55.62

-

-

... More
Walls (any thickness) but not less that 0.10 Mtrs. hick including attached pilasters buttresses plinth and string course from top of foundation upto floor two levels.

102.46

-

-

... More
Suspended floors, roofs, landings, shelves and their supports balconies, beams girders bressumers and cantilevers upto floor two levels

1.7

-

-

... More
Lintels, beams girders bressumers and cantilevers upto floor two level :

2.04

-

-

... More
Providing and laying cement conc. 1:2:4(1 cement:2 sand:4 graded stone agg. 20mm nominal size) and curing complete excluding cosot of form work and reinforcement of RCC work in all leads and lifts as per direction and to the entire satisfaction of the Engineer-in-charge.

-

-

-

... More
Foundation footing and bases of columns & like mass concrete.

5.6

-

-

... More
Column.pillar & post upto floor two level

20

-

-

... More
In suspended floor roofs landing shalves & their support balconies,beams, girders bressumers cantilevers upto floor two level

11.26

-

-

... More
Providing wood work in frames of doors, windows, clearstory window and other frames wrought framd and fixed in position in 2nd class Deodar wood complete. as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.

1.12

-

-

... More
Providing form work with steel plate 3.15 m.m thick welded with angle iron 30x 30 x5 m.m so as to give a fair finish including centering ,shuttering, propping etc. height of propping and centering below supporting floor to ceiling upto all heights and removal of the same for in-situ reinforced conc.and plain conc.work in :-

-

-

-

... More
Flat surface such as soffits and suspended floors, roofs, landings and the like: Floors etc. up to 200mm in thickness within all leads and lifts

195.28

-

-

... More
Vertical surfaces such as walls (any thickness)portions and the like including attached pilaster buttresses plinth and string course and the like

1295.68

-

-

... More
Foundation,footing basis of columns & the like and mass concrete.

38.81

-

-

... More
Sides and Soffits of beams, beam haunchings, contiliver girders, bressumers and lintels not exceeding 1 Metre in depth in all heights from floor complete in all respect with in all leads and lifts.

15.86

-

-

... More
Beams, cantilever Girders& lintals sides&soffits of beams, beams,haunching cantilever girders not exceeding 1mtr. Depth.

21.78

-

-

... More
Providing tor steel reinforcement for RCC work including bending, binding and placing in position i /c binding wire complete up to floor two level complete in all respect as per direction & to the entire satisfaction of Engineer-in- Charge upto all lead & lifts.

14615.92

-

-

... More
Steel work welded in built up sections,trusses & framed work i/c cutting, hoisting & fixing in position & applying a priming coat of red paint :-In grating, framed ,guards, bars,ladders, railing,brackets & similar works with in all leads and lifts as per the entire satisfaction & direction of the Engineer Incharge

1570.1

-

-

... More
Random rubble masonary/Polygonal rubble masonary (coursed or brought to courses with hard stones of approved quality in foundation and plinth including levelling up with cement concrete 1:6:12 in cement mortar 1:6 ( 1 cement : 6 sand)as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.

188.46

-

-

... More
Boulder filling under floor as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.

26.7

-

-

... More
Half Brick work with conventional using comman burnt clay building bricks in super structure up to floor two level 2nd class brick in cement motor 1:4 (1cement:4 sand ) with in all leads and lifts as per the entire satisfaction & direction of the Engineer in charge.

10.9

-

-

... More
Brick work using comman burnt clay building bricks in super structure above plinth level upto floor two level with C.M 1:6 ( 1 cement :6 Sand ) with in all leads and lifts as per direction & satisfaction of Engineer -in-charge. 2nd Class bricks

47.46

-

-

... More
Brick work using common burunt clay building bricks in foundation and plinth in cement mortor 1:6 ( 1 cement :6 Sand ) with in all leads and lifts as per direction & satisfaction of Engineer -in-charge. 2nd Class bricks

7.18

-

-

... More
Providing and laying brick tiles over mumty roofs grouted with cement mortar 1:3 over a 12mm layer of cement mortar 1:3 and finished needly complete with in all lead & lifts and to the entire satisfaction of the Engineer-in-Charge.

36.04

-

-

... More
Cement pointing on Brick Work with cement mortar 1:3 (1Cement : 3Sand) complete with in all lead & lifts and to the entire satisfaction of the Engineer-in-Charge.

134.5

-

-

... More
Providing and fixing pressed steel door, frames, manufactured from comercial mild steel sheet of 1.25 mm thickness including hinges jump block Jamb, beed, and if required angle threshold of mil steel angle of section 50x25mm or base ties of 1.25mm pressed mild steel welded or regidly fixed together by machanical means adjustable lugs with split and tails to each Jamb i/c steel but things 2.5mm thick with guards lock strike plate and shock as specified and applying a coat of applying steel primer after pretreatment of the surfaces directed by the Engineer-in-charge

-

-

-

... More
Profile- A

12.9

-

-

... More
Providing and fixing panelled glazed or panelled and glazed shutters for doors, windows and clerestory windows i/c bright 2nd class deodar wood 40mm thick including entire carriage of material as per satisfaction of E-in-charge.

27.22

-

-

... More
Providing and fixing wire gause shutters using galvanised MS wire gause of IS gause designation 85 G with wire diameter 0.56mm for doors, windows, clerestorey windows I/c bright finished black enamelled iron hinges with necessary secrews 30 mm thick 2nd class deodar wood with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge. 2nd class deodar wood.

28.68

-

-

... More
Providing and laying 40mm thick cement concrete flooring 1:2:4 ( 1cement:2 sand: 4 crushed graded stone aggregate 20 mm nominal size ) laid in one layarer finished with a floating coat of neat cement and curing complete as per direction & to the entire satisfaction of Engineer-in- Charge upto all lead & lifts.

2.88

-

-

... More
6 mm cement plaster to ceiling in CM 1:3 ( 1Cement :3 Sand) as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.

188.67

-

-

... More
15 mm thick cement plaster on rough sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cement mortar 1:6 (1cement:6sand) with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge.

219.54

-

-

... More
20 mm thick cement plaster on rough sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cement mortar 1:6(1cement:6sand) with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge.

30.66

-

-

... More
White washing with lime on undecorated wall surfaces(two coats) to give an even shade I/c thoroughly brooming the surface to remove all dust dirt & other foreign matter as per direction & to the entire satisfaction of Engineer-in- Charge upto all lead & lifts.

240.16

-

-

... More
Distempering (two coats) with oil bound washable distemper of approved brand and manufacture and of required shade on undecorated wall surfaces to give an even shade over and including a priming coat with distemper primer of approved brand and manufacture after thoroughly brushing the surface free from mortar droppings and other foreign matter and also including preparing the surface even and sand papered smooth. Priming coat with distemper primeras per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.

168.06

-

-

... More
Finishing wall with water proofing cement paint of approved brand and manufacture and of rerquired shade on undecorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials.

30.66

-

-

... More
Applying priming coat on new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil,greese,dirt and other foreign matters,sand papering and knotting.Ready mixed paint brushing wood primer pink. as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.

54.44

-

-

... More
Painting two coats(excluding coat) on new wood and wood based surface with enamel paint to give an even shade including cleaning the surface of dirt,dust and other foreign matter,sand papering & stoping with animal paint other then white and as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.

54.44

-

-

... More
Precast terrazo tiles 20m thick (with marble chips of specified shadeand of specified laid in floor treads of steps and landingon bed on10mm thick cement plaster 1:6 (1cement: 6sand ) jointed withneat cement slurry mixed with pigment to match the shade of tiles. selvary grey complete with in all lead & lifts and to the entire satisfaction of the Engineer-in-Charge.

99.26

-

-

... More
Providing & fixing M.S. grills of required pattern in wooden frame of window etc.with M.S. flats, square or round barswith round headedbolts and nuts by screws plain grills. as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.

143

-

-

... More
Providing and fixing MS sliding door bolts with bolts and nuts screws etc. complete and as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts. 250x16 mm.

2

-

-

... More
300x16 mm.

4

-

-

... More
Providing and fixing MS tower bolts ( barrel type) with screws etc. complete and as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts

-

-

-

... More
200x10 mm

60

-

-

... More
250x10 mm

6

-

-

... More
Providing ad fixing MS handles with necessary screws etc. complete as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.

-

-

-

... More
125mm

46

-

-

... More
Providing 40x3 mm flat iron hold fast 40cm. Long including fixing to frame with 10mm dia metres bolts, nuts and wooden plug and embedding in cement concrete block 30x10x15cm. 1:3:6( 1cement:3sand:6 graded stone att. 20mm nominal size) within all leads and lifts and as directed by the Engineer-in-charge.

60

-

-

... More
Providing plinth protection 50mm thick in cement concrete 1:3:6(1cement: 3sand: 6graded stone agg. 20mm nominal size) i/c finishing the top surface of concrete smooth within all leads and lifts and as directed by the Engineer-in-charge.

27.82

-

-

... More
ProvidingProviding under layer for plinth protection of 75mm thick (unconsolidated) bed dry brick/stone aggregated 40mm nominal size with rammed and consolidated and grouted with fine sand including preparation of ground. within all leads and lifts and as directed by the Engineer-in-charge.

27.82

-

-

... More
Providing and placing ( at all hights) polyethylene water storage tank ISI-12701 Marked indicating the BIS license no. with cover & suitable locking arrengement & making necessary holes for inlet, outlet & over flow pipes includingall fittings & float balve excluding the base support for tank ( Sintex, Electroplast, Star, Lotus or euqivalent having valied ISI license). 300 lts. capacity.

2

-

-

... More
Fixing to wall ceiling and floor galvanised mild steel tubes (Medium grade) tube fittings and clamp including making good the wall ceiling and floor in all leads and lifts.) 15 mm nominal bore

24

-

-

... More
Providing and fixing vitreous china wash down water closet (Anglo Indian, W.C pan) with integral P or S trap including jointing the trap with soil pipe in cement mortar 1 : 1 ( 1 cement 1 sand) ( Seat and cover to be measured and paid for separately) (White colour)

2

-

-

... More
Providing and fixing plastic seat (Solid/Hollow type) and cover for wash down water closet with C.P. brass hinges and rubber buffers :- solid type white plastic seat and cover in all leads and lifts.

2

-

-

... More
Providing and Fixing PVC low level flushing cistern with manually controlled device ( handle lever) coforming to IS: 7231, with all fitting & fixtures complete10 ltrs capacity- White.

2

-

-

... More
Providing and Fixing PVC/ GI inlet connection for flush pipe connecting with WC pan ISI marked complete including fixing with approved etc.

2

-

-

... More
Providing and fixing brass stop cock ( Concealed) of standard design & of approved make coforming to IS: 8931. 15mm nominal bore. complete in all leads and lifts.

2

-

-

... More
Providing and fixing CP brass angle balve of standard design & of approved make. 15mm nominal bore. complete in all leads and lifts.

4

-

-

... More
Providing and fixing CP water jet including connection pipe with check nut complete in all leads and lifts.

2

-

-

... More
Providing & fixing PVC pipe of 10.00 Kg. F/Cm Sqm. Working pressure including fittings as per requirement at site. 110 mm OD.

20

-

-

... More
Laying jointing of G.I pipes (L.G) ,tube fitting in trenches i/c earth work complete for inlet and scour pipe including all leads and lifts. 80mm (L.R)

152

-

-

... More
65 mm

102

-

-

... More
50 mm

102

-

-

... More
Providing & fixing CI Sluice valve (with hand wheel) as per IS : 780-1984 class-I upto 300mm dia.(i/c brass spindle & as per 2906-1984class-II for dia. 300 mm) complete with bolts nuts,rubber insertion etc.,(the tail piece if req-uired shall be measured & paid for separatly including all leads and lifts:

-

-

-

... More
80mm

18

-

-

... More
50 mm

17

-

-

... More
Providing and Fixing of 1.80 metre high fencing with 2.50 metre angle iron post 50 x 50 x6 mm , 2.50 metre centre to centre with nine horizontal lines and two diagonals of galvanised steel bar bed wire (IS:278-1962 type-I) weighing 9.38 kg/per 100 metre (minimum) strained and fixed to posts with GI staples, including providing red oxide paint to post . The item includes cost of post, barbed wire and fixing etc. complete.

572.36

-

-

... More
Laying, jointing and testing in trenches galvanized mild steel screwed and socketed /flanged pipes of following diameter and class i/c cost of tube fittings like Tee, Union & short pieces etc.in trenches i/c carriage of pipes from Divisional Store to site of work,(Earth work in trenches to be measured and paid for separately) complete in all respect and to the entire satisfaction of the Engineer-in-charge:(LR)

-

-

-

... More
40 MM.

5650

-

-

... More
50 MM.

5550

-

-

... More
65 MM.

7280

-

-

... More
100 MM.

300

-

-

... More
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. complete with in all lead & lifts and to the entire satisfaction of the Engineer-in-Charge. (Group C)

44

-

-

... More
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. complete with in all lead & lifts and to the entire satisfaction of the Engineer-in-Charge.

-

-

-

... More
2x1.5 Sq.mm

100

-

-

... More
2x4.0 Sq.mm

50

-

-

... More
Supplying and Fixing 3 way 5/6 amps. . Socket outlet on the exist switch box/ covers inculding connection etc. as required .

6

-

-

... More
Supplying and Fixing 2 way 5/6 amps. . Tumbler / piano type switch on the existing switch box on the switch box/ covers inculding connection etc. as required .

6

-

-

... More
Supplying and Fixing 3 way 15/16 amps. . Socket outlet on the exist switch box/ covers inculding connection etc. as required .

6

-

-

... More
Supplying and Fixing 2 way 15/16 amps. . Tumbler / piano type switch on the existing switch box on the switch box/ covers inculding connection etc. as required .

6

-

-

... More
Supplying and Fixing Wooden box of following size ( norminal) on surface or recess with suitable size of phenolic laminated sheet cover of in front as required

-

-

-

... More
229mmx102mmx60mm

6

-

-

... More
203mm x152mm x60mm

6

-

-

... More
supplying and fixing ceiling rose on existing junction Box / wooden block including connections etc. as required

18

-

-

... More
Supplying and Fixing plain pandent with 16/20 mm twin twisted , flexible PVC insulated cooper cable and backelite pendent holder including connections , etc. as required.

6

-

-

... More
Supplying and fixing 5 Amps to 32 Amps rating , 240Volts , L series miniature circuit breaker of following poles in the existing MCBDB complete with connections testing and commissioning etc. as required cat A ( Single Pole )

12

-

-

... More
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-

-

-

-

... More
Single door-8 way

2

-

-

... More
Supplying and fixing following rate , double pole , 240 volts isolator in the existing MCB DB complete with connections testing and commissioning etc as per required ( 63amp CAT -A)

2

-

-

... More
Providing , installing , testing and commissioning of ceiling Fan and regulator i/c wiring the down rod of standard length ( upto 30cm with 1.5 Sqmm PVC insulated copper conductor single core cable . As required ceiling fan 1400 mm sweep category A

2

-

-

... More
Prroviding and Fixing ultra silm Decorative extruded box fixture with domestic electronic ballast , snap -on installers suitable for 28 watt FTL ( T5 ), complete with all accessories ( including one No T-5 tube ), connections testing and commissioning etc. as required.)

8

-

-

... More
providing and Fixing LED Flood light watt mentiord below ( OREVA make ) ccomplete in all respact in all leads and lifts.)

6

-

-

... More
Providing and Fixing two core service wire 6 sqm thick in all leads and lifts .

90

-

-

... More
Providing , laying, fixing, jointing and testing in trenches MSERW pipe L-210 of following dia meters confirming to confirming to BIS 3183-2007, of following grade and having wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, providing and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).

-

-

-

... More
1st Stage RD From To Length in mtrs Pipe (MM) Wall Thickness Flange table 0 300 300 150 4.8 34 Flanged Length @5% of total length 15

15

-

-

... More
2nd Stage RD From To Length in mtrs Pipe (MM) Wall Thickness Flange table 0 500 500 100 4.8 34 Flanged Length @5% of total length 25

25

-

-

... More
Providing , laying,jointing ( by way of circumfrential butt welded joints by electrical arc welding ) and testing of MSERW pipe L-210 of following dia meters confirming to BIS 3183-2007, steel grade specified below (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).

-

-

-

... More
1st Stage RD From To Length in mtrs Pipe (MM) Wall Thickness 0 300 300 150 4.8 Length of butt welding @95% of total length 285

285

-

-

... More
2nd Stage RD From To Length in mtrs Pipe (MM) Wall Thickness 0 500 500 100 4.8 Length of butt welding @95% of total length 475

475

-

-

... More
Laying,jointing ( by way of circumfrential butt welded joints by electrical arc welding ) and testing of Galvanised mild steel tubes (GI Pipes) of following dia meters confirming to BIS 1239-2001 (latest with upto date amendments) having wall thickness as per code with bevelled / plain ends in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, bends etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The damaged portion of the pipes and specials made form the parent tube during welding or otherwise shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).( LR)

-

-

-

... More
1st Stage RD From To Length in mtrs Pipe (MM) Class MC Wall Thickness 300 945 645 150 4.8 Length of butt welding @95% 613

613

-

-

... More
2ndStage RD From To Length in mtrs Pipe (MM) Class MC Wall Thickness 500 1090 590 100 4.5 Length of butt welding @95% 561

561

-

-

... More
Providing, laying, jointing and testing in trenches to be levelled to grades, GI flanged pipes of following diameter confirming to IS:1239-1990( Part-II) having minimum wall thickness as per IS code and class of pipes specified below, provided and jointed with flanges conforming to tables as specified below of BIS 6392-1971 welded at both ends according to relevant BIS standards and detailed specifications and provided with nut & bolts of required sizes, 3mm thick compressed asbestos fiber jointing gasket / synthetic rubber gasket confirming to relevant BIS codes including all kinds of flanged short pieces, bends, tees & other specials etc made from parent tubes & welded with flanges of tables as applicable for the particular reach as per site conditions including flushing, cleaning & hydraulic testing as per directions of Engineer-in-charge. (LR)

-

-

-

... More
1st Stage RD From To Length in mtrs Pipe (MM) Wall Thickness Flange Table 300 945 645 150 4.8 28 Flanged Length @5% 32

32

-

-

... More
2nd Stage RD From To Length in mtrs Pipe (MM) Wall Thickness Flange Table 500 1090 590 100 4.5 28 Flanged Length @5% 29

29

-

-

... More
1st Stage Pumping Machinery Providing horizontal spindle,horizontal/redial split casing/end suction(Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements: .

2

-

-

... More
Discharge (Q) 7.71 LPS for each pump

-

-

-

... More
Total Dynamic head:- 412.68 meter

-

-

-

... More
a) LWL in sump well (h) 1800.30 Meter

-

-

-

... More
b) Shaft level 1800 meter

-

-

-

... More
c) Level at discharge point 2200 meter

-

-

-

... More
d) Suction lift +ve

-

-

-

... More
f) Static head 400 meter

-

-

-

... More
Rising main

-

-

-

... More
a) Length 945 mete

-

-

-

... More
b) Dia 150 mm

-

-

-

... More
Pumping hours 20 Hours

-

-

-

... More
Altitude of installation above MS 1800 meters

-

-

-

... More
Characterstics of water : Clear water with turbidity up to 50 PPM.

-

-

-

... More
a) Temperature 20 degree centigrade.

-

-

-

... More
Note: Two pump sets will run parllel to lift the total discharge of 15.42 LPS .

-

-

-

... More
Providing ICTP main switch with HRC fuses of Kilburn/ L&T/ Siemens /Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL.

1

-

-

... More
Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities

1

-

-

... More
a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments

1

-

-

... More
b) Earth leakage circuit breaker of recommended make (Kilburn/L&T /MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurance of earth fault on off breaker load side end.

1

-

-

... More
c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)

1

-

-

... More
d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments

1

-

-

... More
e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments

1

-

-

... More
f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments

1

-

-

... More
g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments

1

-

-

... More
h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/ Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments

2

-

-

... More
i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments

2

-

-

... More
j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/ MP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments

2

-

-

... More
k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments

2

-

-

... More
l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments

2

-

-

... More
m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)

2

-

-

... More
n) Providing antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971.

2

-

-

... More
Providing double flanged CI sluice valve PN1 of Leader/BHEL/Kirlosker/ GLEd /Kilburn Fourses / Kartar make and equal to dia of suction pipe and cpable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments

2

-

-

... More
Providng double flanged cast steel sluice valves ASA-300 of leader/BHEL Kirlosker/Kilburn GLED/fourses make and one step higher then delivery line of pump and capable of withstanding the normal seat pressure and as per BIS standards with upto date ammdnements

2

-

-

... More
Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)

2

-

-

... More
Providing double flanged cast steel reflux valves class ASA-300 of Leader/ BHEL/KILROSKER/Kartar/KILBURN/GLED/FOURSES make and of 150 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments.

1

-

-

... More
Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.

2

-

-

... More
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments

1

-

-

... More
Installation of all the items apparing at serial No.1 to 10 as per the systematic drawing

1

-

-

... More
Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:

-

-

-

... More
Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe

10

-

-

... More
Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe

10

-

-

... More
Common header : One dia higher then delivery of pump x 150 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed

5

-

-

... More
Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor

-

-

-

... More
(a) Motor side (From switch to starter and starter to motor)

10

-

-

... More
(b) Supply side (From Meter of HPSEB to bus bar and switch)

10

-

-

... More
Providing and fixing double loop earth with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect.

1

-

-

... More
2nd Stage Pumping Machinery Providing horizontal spindle,horizontal/redial split casing/end suction(Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements: .

2

-

-

... More
Discharge (Q) 6.38LPS for each pump

-

-

-

... More
Total Dynamic head:- 461.15 meter

-

-

-

... More
a) LWL in sump well (h) 2198.5 meter

-

-

-

... More
b) Shaft level 2197.2 meter

-

-

-

... More
c) Level at discharge point 2600 meter

-

-

-

... More
d) Suction lift +ve

-

-

-

... More
f) Static head 402.80 meter

-

-

-

... More
Rising main

-

-

-

... More
a) Length 1090 meter

-

-

-

... More
b) Dia 100mm

-

-

-

... More
Pumping hours 20mm

-

-

-

... More
Altitude of installation above MS 2200 meter

-

-

-

... More
Characterstics of water : Clear water with turbidity up to 50 PPM.

-

-

-

... More
a) Temperature 20 degree centigrade.

-

-

-

... More
Note: Two pump sets will run parllel to lift the total discharge of 12.76 LPS .

-

-

-

... More
Providing ICTP main switch with HRC fuses of Kilburn/ L&T/ Siemens /Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL.

1

-

-

... More
Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities

1

-

-

... More
a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments

1

-

-

... More
b) Earth leakage circuit breaker of recommended make (Kilburn/L&T /MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurance of earth fault on off breaker load side end.

1

-

-

... More
c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)

1

-

-

... More
d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments

1

-

-

... More
e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments

1

-

-

... More
f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments

1

-

-

... More
g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments

1

-

-

... More
h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/ Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments

2

-

-

... More
i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments

2

-

-

... More
j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/ MP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments

2

-

-

... More
k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments

2

-

-

... More
l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544: 1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments

2

-

-

... More
m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)

2

-

-

... More
n) Providing antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971.

2

-

-

... More
Providing double flanged CI sluice valve PN1 of Leader/BHEL/Kirlosker/ GLEd /Kilburn Fourses / Kartar make and equal to dia of suction pipe and cpable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments

2

-

-

... More
Providng double flanged cast steel sluice valves ASA-300 of leader/BHEL Kirlosker/Kilburn GLED/fourses make and one step higher then delivery line of pump and capable of withstanding the normal seat pressure and as per BIS standards with upto date ammdnements

2

-

-

... More
Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)

2

-

-

... More
Providing double flanged cast steel reflux valves class ASA-300 of Leader/ BHEL/KILROSKER/Kartar/KILBURN/GLED/FOURSES make and of 150 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments.

1

-

-

... More
Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.

2

-

-

... More
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments

1

-

-

... More
Installation of all the items apparing at serial No.1 to 10 as per the systematic drawing

1

-

-

... More
Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:

-

-

-

... More
Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe

10

-

-

... More
Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe

10

-

-

... More
Common header : One dia higher then delivery of pump x 150 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed

5

-

-

... More
Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor

-

-

-

... More
(a) Motor side (From switch to starter and starter to motor)

10

-

-

... More
(b) Supply side (From Meter of HPSEB to bus bar and switch)

10

-

-

... More
Providing and fixing double loop earth with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.