Himachal Pradesh Irrigation And Public Health Department Tender
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender
Eprocure
Opening Date9 Apr 2021
Closing Date19 Apr 2021
Tender AmountRefer Documents
Costs
EMD
₹ 16,100Document Cost
₹ 250Tender Fee
Refer Documents
Summary
Construction Of Storage Tank To Harizan Basti Ropari In Tehsil Jhandutta District Bilaspur
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_HPIPH_46423_1Bid Award Id
ViewTender No
JHT-BLP03-782Tender Authority
Himachal Pradesh Irrigation And Public Health Department ViewPurchaser Address
-Website
http://http://hpiph.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Ist Stage GMS pipe (Heavy Class) 50 mm dia. with wall thickness of 4.50
450
-
-
GMS pipe (Medium Class) 50 mm dia. with wall thickness of 3.60
810
-
-
Providing circumferencial Butt welded joints by electrical arc welding to GMS/MSERW pipe, welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS: 816-1969 specifications, by using welding electrodes of 2.50 mm to 6.30 mm of Advani , Oerlikon (Adore)-CITOJET/ESAB make conforming to IS:814-1991, at site of work complete in all respects, including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
-
-
-
GMS pipe 50 mm dia.
223
-
-
Providing and welding M.S. flanges at suitable points to be provided 5% of total joint and remaining 95% joints with butt welded joint, conforming to following tables as per IS 6392-1971 (Latest with upto date amendments) with plain end GMS/GMSERW pipe in requsite ( minimum three) number of layers on both faces to make the joint leak proof. The welding of flanges should confirm to IS:816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1369-1965 including cost of gasket sheet, nuts & bolts. The thickness of gasket sheet not less then 3.00 mm confirming to IS 2712-1998. The work shall be done to the entire satifaction of engineer in charge with in all leads and lifts.
-
-
-
GMS pipe (Medium Class) 50 mm dia with wall thickness of 4.50, Flange Table 28.
4
-
-
GMS pipe (Medium Class) 50 mm dia with wall thickness of 3.60, Flange Table 17.
9
-
-
Providing and fixing double flanged Cast Steel Reflux valve 50 mm dia Class ASA 150 of Leader/ Kirloskar/ KSB make for rising main and capable of with standing 21 Kg/cm2 normal seat pressure conforming to BS:1868/API-600 or latest ammendments.
1
-
-
Providing/Installation, erection, testing and commissioning of star rated energy efficient Submersible pumping set of KSB/Calama/ Johnston/ Crompton/BS/ SABAR/ Oswal/ Kirloskar make conforming to latest relevant BIS Code . The pump should be fitted with bronze impeller or suitable alloys suitable for handling Clear water having greased packed bearings and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) of required HP & 2900 RPM or as per manufacturer's specifications of reputed make confirming to BIS 9283-1979 latest with upto date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guards, erection clamps , cable clips, depth gauge NRV & Sluice valves of approved class etc. The work should be completed to the entire satisfaction of the Engineer-in – Charge. Discharge:- 1.466 LPS per set, Total dynamic head :- 106.95 metre, LWL in sump well :- 500.00 metre, Static head:- 99.00 metre , Dia of Rising Main:- 50 mm , Length of Rising Main:- 145 Rmt, Pumping Hours:- 8 hours, Coupling :- 2 sets, Turbidity :- less than 50 NTU, Temprature 20 degree to 45 degree centigrade. Limits of total head :- (-) 15% to (+) 10%.
2
-
-
Providing and Installation of suitable direct on line of MEI/Kilburn make starter confirming to BIS 8544 -1979 latest with upto date amendments for electric induction motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release with initial oil filing of suitable capacity.
2
-
-
Providing and fixing of M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal electric duly painted. The drawing of panel board shall be subject to approval of Engineer in charge
1
-
-
Providing & fixing of 125 mm Square type auto electric AC supply Ammeter of AE /L&T/ Rishab make of suitable range with selector switches confirming to BIS 1248 - 1983 latest with up to date amendments.
1
-
-
Providing and fixing of 125 mm square type auto electric A.C. supply voltmeter of AE/L&T /Rishab make of 0-500 volts range with selector switches confirming to BIS: 4064-1978 with up to date amendments.
1
-
-
Providing and fixing of ICTP switches with HRC fuses of L&T/ Crompton /Havells make for required motor of suitable capacity as per IS: 4064-1978 with up to date amendments.
1
-
-
Providing and fixing of Bus bar chamber having 3 core copper bars of suitable rating for full length of three phase and one bar of half the rating of full length for neutral confirming to BIS 8064-1976 and 11353-1985 read with 5578-1985- latest with up to date ammendments .
1
-
-
Providing and fixing of MCB of Havell/MDS/ Kilburn Jyoti make of suitable capacity on incoming feeder with initial oil filling as per IS: 2516-1985 latest with up to date amendments with neutral linked under voltage release.
1
-
-
Providing and fixing Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I&II) with up to date amendments of 15 watts.
1
-
-
Providing and fixing 50 mm dial hour run metre of CEE/NEE make of suitable range as per relevant BIS specifications.
1
-
-
Providing and fixing double flanged Cast iron sluice valve of Leader/Kirloskar/Kartar make class PN 1.60 of one dia higher than pump size to delievery of pump and capable of withstanding the normal seat pressure of 16.32 Kg/cm2 as per IS: 780-1984 with up to date amendments. Head including water hammer effect = 148.82 metre.
1
-
-
Providing and fixing double flanged Cast iron swing check type reflux valve one dia higher than pump delivery of Leader/Kirloskar/Kartar make class PN 1.6 and capable of withstanding the normal seat pressure of 16.32 Kg/cm2 as per BIS: 5312-1984 Part I with up to date amendments.
1
-
-
Providing and laying copper PVC insulated armoured power 3.5 core cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. Motor side: suitable capacity Min length = 20 mtrs. Supply side: suitable capacity Min. length =10 mtrs.
1
-
-
Providing and fixing of PVC joint less flat water proof cable as per BIS 694-1990 latest with up to date amendments suitable for the pump sets offered from MCB to motor including all other electrical equipments/ accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities same shall be replaced by the bidder.
1
-
-
Providing and Laying double loop earthing with copper plate complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx3mm copper strips, digging of pits & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
1
-
-
Providing and fixing 100 mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0-16 Kg/cm2
1
-
-
Providing and laying delivery pipe 50 mm dia and common header 50 mm dia GMS tubes Medium class as per IS 1239-1979 jointed with MS flanges of table 17 as per IS 6392-1971 up to a length of 20 metres including rappers, flanges, rubber gaskets, nuts and bolts bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications up to 5 metre away from the outer wall of pump houses. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
1
-
-
Providing and fixing of floor/ wall mounted power factor shunk capacitor of L&T/Bajaj/Assian/Crompton make as per IS:2834-1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVAR rating according to HP offered including cables as per relevant ISI code of Siemens/Gloster/IEC make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064-1978 with upto date amendments .
2
-
-
1ST STAGE Providing & Installation of horiontal spindle horizontal split casing / end suctions (back pull out arrangement ) single /double/multistage centrifugal pump or combination of pump in series of Mather and Platt / KSB/Kirloskar / Crompton / BS make as per BIS 1520-1980 with up to date amendments, read with IS:9137-1978 or latest edition suitable for lifting clear water . The pump should be fitted with bronze impellers of suitable alloys, priming funnels , casing rings, shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on MS/ Cast steel base plate ( base plate to be provided from the manufacturer,s of the pumping unit only) to slippering type drip proof induction motor of standard make such as Kirloskar/Crompton/ BHEL confirming to BIS 9238-1979 latest with up to date amendments and suitable for operation on 400 (+/-) 10% volts, 50 cycles / second, three phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of + 10% and - 15% of the duty point head. The motor should be as per IS 325-1978 with up to date amendments.The pump set should suitable for operation on data given below:- Discharge:- 1.46 LPS per set, Total dynamic head :- 222.56 metre, LWL in sump well :- 737.60 metre, Shaft level:- 737.60 metre , Level at discharge point :- 923 metre , Residual head:- 3 metres, Static head:- 185.40 metre , Dia of Rising Main:- 50 mm , Length of Rising Main:- 1260 Rmt, Pumping Hours:- 8 hours, Coupling and base plate :- 2 sets, Turbidity :- less than 50 NTU, Temprature 20 degree to 45 degree centigrade.
2
-
-
Providing / fixing ICTP Main Switch with HRC fuses / side handled operated change over switch of L&T / crompton/ stanadards/ Havells make of suitable capacity operational rating as per IS 4064(part II) 1978 with up to date amendments)
2
-
-
Providing and fixing of M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal electric duly painted. The drawing of panel board shall be subject to approval of Engineer in charge
2
-
-
Providing / fixing OCB of Havells/ MDS/ standared make of suitable capacity on incoming feeder with or without initial oil filling as per IS 2516-1985 with up to date amendments.
2
-
-
Providing / fixing ELCB of Havells/ MDS/ INDETEC make of suitable capacity as per ISD 2516-1977 with up to date amendments which should have conterol box operating handle and trip / reset push button on/ off indicators with up to date amendments.
2
-
-
Providing / fixing voltage monitor relay of L&T/ AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage , reverse phasing, over loading and phase voltage difference as per IS 3842 Latest edition.
2
-
-
Providing & fixing of 125 mm Square type auto electric AC supply Ammeter of AE /L&T/ Rishab make of suitable range with selector switches confirming to BIS 1248 - 1983 latest with up to date amendments.
2
-
-
Providing and fixing of 125 mm square type auto electric A.C. supply voltmeter of AE/L&T /Rishab make of 0-500 volts range with selector switches confirming to BIS: 4064-1978 with up to date amendments.
2
-
-
Providing / Fixing power factor meter of AE /L&T /Rishab make as per relevant IS code with up to date amendments of suitable rating.
2
-
-
Providing / Fixing frequency meter of AE /L&T /Rishab make as per relevant IS code with up to date amendments of suitable rating.
2
-
-
Providing and fixing of Bus bar chamber having 3 core copper bars of suitable rating for full length of three phase and one bar of half the rating of full length for neutral confirming to BIS 8064-1976 and 11353-1985 read with 5578-1985- latest with up to date ammendments .
1
-
-
Providing and fixing of ICTP switches with HRC fuses of L&T/ Crompton /Havells make for required motor of suitable capacity as per IS: 4064-1978 with up to date amendments.
2
-
-
Providing and fixing Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I&II) with up to date amendments of 15 watts.
2
-
-
Providing and fixing of floor/ wall mounted power factor shunk capacitor of L&T/Bajaj/Assian/Crompton make as per IS:2834-1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVAR rating according to HP offered including cables as per relevant ISI code of Siemens/Gloster/IEC make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064-1978 with upto date amendments .
2
-
-
Providing and Installation of suitable star delta starter of MEI/Kilburn make starter confirming to BIS 8544 -1979 latest with upto date amendments for squarrel cage motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release with initial oil filing as per IS 1248 PV-1983 with up to date amendments.
2
-
-
Providing and fixing 50 mm dial hour run metre of CEE/NEE make of suitable range as per relevant BIS specifications.
2
-
-
Providing and fixing double flanged Cast iron sluice valve of Leader/Kirloskar/ Kartar make class PN 1.00 of 50 mm dia capable of withstanding the normal seat pressure of 10.20 Kg/cm2 as per IS: 780-1984 with up to date amendments complete in all respects.
2
-
-
Providing and fixing double flanged Cast Steel sluice valve Leader/Kirloskar/KSB make one dia higher than pump delivery of pump class ASA 300 capable of withstanding the normal seat pressure 52 kg/cm2 as per IS: 1414/ API 600 with up to date amendments.
2
-
-
Providing and fixing double flanged Cast Steel reflux valve Leader/Kirloskar/KSB make one dia higher than pump delivery of pump class ASA 300 capable of withstanding the normal seat pressure 52 kg/cm2 as per BS: 1868/ API 600 with up to date amendments.
2
-
-
Providing and fixing double flanged Cast steel non return valve Leader/Kirloskar/KSB make 50 mm dia withstanding the normal seat pressure 52 kg/cm2 as per BS 1868 API 600 class ASA 300 with up to date amendments .
1
-
-
Providing and fixing 125 mm circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0- 52 Kg/cm2
2
-
-
Providing and fixing double flanged GMS piping network for suction and delivery pipes suitable to pumps offered and common header as per the rising main respectively complete with all specials such as rappers, flanges, rubber gaskets minimum 3 mm in thickness as per IS 2712-1979, nuts and bolts as per IS:1364-1983, bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as per drawing up to 5 metre away from the outer wall of pump houses. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated.The size of various components are as under:- Suction pipe 65 mm dia M.C Minimum length= 5 metre, Delivery pipe 40 mm dia M.C Minimum length= 10 metre, Common header 50 mm dia M.C Minimum length = 10 metre , The GMS tube confirming to IS :- 1239-1979 part-I Medium class flanged with MS flanges of table 28 in suction pipe and heavy class flanged with MS flanges of table 28 in delivery side and common header.
1
-
-
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
1
-
-
Providing and fixing double loop earthing with copper strips & copper plate 600 x600x3 mm thick complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx3mm copper strips, digging of pits & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
1
-
-
Evaluation Notes How It Works ?
Potential Partner