Himachal Pradesh Irrigation And Public Health Department Tender

... More
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender

Works
Civil And Construction
Pipe Line Project
Eprocure
Opening Date21 Feb 2025
Closing Date4 Mar 2025
Tender Amount₹ 1,58,01,408 
Notes
Download

Costs

Summary

Providing Lwss Bag Habra And Adjoining Village Of Gp Bhajon And Gp Kathwar In Tehsil Kamroo Distt Sirmour Hp Under Nabard

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and lowering of IS Marked riser pipes, medium class screwed and socketed and welded as per IS 1239- (Part-1) with up to date amendments, electric resistance welded inculuding cost of all cutting ,Threading and welding, wherever required in random length of 3 mtr inclusive of transportion charges to the site complete in all respect as per direction of engineer in charge thick fincut MSERWW casing plain and casing MSERW pipes as per IS: 4270-2001 with upto date ammendments in a length of 3.00 meters including cutting, welding, transportation charges complete in all respect.

-

-

-

... More
65 mm dia GMS pipe

30

-

-

... More
Providing and fixing suítable casing shoe and bit tube as per requirement of ODEX attachment complete in all respects as per directions of Engineer-in-Charge

1

-

-

... More
Development of borewell and yield testing with air-compressor through V notch and disinfection etc. complete in all respecS as per IS 2800 : 1979 and as per directioe Engineer-in-Charge

1

-

-

... More
Pumping Machinery Booster Stage

-

-

-

... More
Supply, erection, testing & commissioning of submersible pumping set of reputed make such as KSB/BS/ Johnston/ Worthington/Oswal/Sabar Brand or any other reputed make conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having characterstics as mentioned in item 7(A) greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guard, errection clamps, cable clips. & depth gauge etc. & suitable for operation of data given below:- (Note:- Tender to be called for per set not for per HP rate)

2

-

-

... More
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 50.50 mtr

-

-

-

... More
Capacity (in LPS) 6.08 LPS

-

-

-

... More
Dia of R/Main (in mm) 100 MM

-

-

-

... More
Length of rising main (in mtr.) 30 metres

-

-

-

... More
2X7.50 HP = 15 HP

-

-

-

... More
Providing and fixing of auto control panel with push button star delta starter( 2 Nos.) for submersible pump of L&T and reputed make fabricated with M.S. sheet and angle stand duly painted and complete with internal wiring, comprising of main switch of suitable Amp., T.P. volte meter, copper busbar, ameter, hour run metre, phase indicating lamps with GMS based, remote start/stop operation call/SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hour in a day, imbuilt protection against overload/ undervoltage, dry run, single phase preventer, inbuilt GPS tracker, phase reversal configurable volt/current limits with a facility to access the system through minimum 10 No. authenticate mobile Nos. complete in all respect, including intire carriage of materials all leads and lifts, installation and testing at site with entire saisfaction of engineer-in-incharge.(all meters to be installed shall be DIGITAL)

1

-

-

... More
Supply & fitting of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make of suitable size cast iron double flanged sluice valve having size one size larger than the nominal diameter of delivery of the pump or equal to dia. of column pipe (in case of t/well) and capable of withstanding nominal seat pressure as mentionmed in item No. 7(a)+ surge pressure conforming to API-standards with up to date ammendments for delivery line of pump. class of valve shall be PN 1.60.

2

-

-

... More
Supply & fitting at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make of suitable size cast iron double flanged swing check type reflux valve having bye pass arrangement & size one size larger than the nominal diameter of delivery of the pump or equal to dia. of column pipe (in case of t/well) and capable of withstanding nominal seat pressure as mentionmed in item No. 7(a)+ surge pressure conforming to API-standards with up to date ammendments for delivery line of pump. class of valve shall be PN 1.60.

2

-

-

... More
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ICC/EICO/National /IEC make from meter of HPSEB to circuite breaker & from circuite breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.

10

-

-

... More
Providing and laying at site jointless flat water proof cable as per BIS 694-1990 (latest with up to date amendments) suitable for both the pump sets offered from circuite breaker to motor & motor to starter including all other electrical equipments such as thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.

45

-

-

... More
P/L double loop earthing of booster and first stage with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.

1

-

-

... More
Providing and lowering MSERW column pipe assembly GMS (M Grade) and 100 mm dia. Including MS flanges as per IS-3183-2007 with up to date amendments, rubber/asbestos gasket of maximum 3 mm thickness as per IS: 2712-19/9 and required numbers of nuts and bolts as per IS: 1364-1983. The column pipe shall be as per relevent IS: code and to with stand 1.5 times total head stipulated under item no- 7(a). The column pipe shuld be extended up to 5 mtrs. beyond the outer wall of the pumphouse in the direction of Rising main. The column pipe should be properly jointed with the Rising main including all neccessary accessaries like increaser/reducer, flanges, tees, bends etc. including supporiing clamps (2 nos) at the top of assembly and conforming and as per the direction of engineer-in-charge.

22

-

-

... More
Pumping Machinery 1st Stage

-

-

-

... More
Supply, erection, testing & commissioning of horizontal spindle, horzontal split casing radial split single /multistage centrifugal pumps of standard make such as KSB/ Mather & Platt/ Jyoti/ Kiroskar /Beaconweir/ BS & BE or any other reputed make conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to handel clear water having characteristics as mentioned below in ltem no 12(A), with impelleres,casing ring priming funnels & shaft sleeves of bronze , shaft of steel of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel/ Mild steel to BHEL/ Kirlokar/ NGEF/Crompton/Siemen /jyoti/GEC make slip ring /squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below i/c the cost of all the accessories in all leads and lifts & carriage at the site sites as per direction of Engineer-in - charge. :-(Note:- Tender to be called for per set not for per HP rate)

2

-

-

... More
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 594 mtr

-

-

-

... More
Capacity (in LPS) 6.08 LPS

-

-

-

... More
Dia of R/Main (in mm) 100 MM

-

-

-

... More
Length of rising main (in mtr.) 1800 metres

-

-

-

... More
2X100 HP = 200 HP

-

-

-

... More
Supply, installation, Testing and Commissioning of Fully Autometic LT Panel for centrifugal pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opening door type switch board with copper insulated wiring suitable to operate 2 No. pump of rating suitable HP automatically through variable Frenqency Drive Starter. Starter should be capable to handle all rth faults like short circuit, over current. under current, over voltage, under voltage, dry pump protection. It should get on and off command automatically from PLC and HMI. Monitoring and controlling of Pump running and trippng status should be monitored and controlled remotely through IOT enabled device. Access shoild be given to 3 users. Reputed make. i) Energy saving variable freqency drive starter of suitable HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It should be cable to control the frequecy of pumps through out the opration and also should be cabable to maintain the power factor of the system within acceptable limits. It should be able to withstand ambient temprature 50 Degree ceicius without derating and have conformal coating class 3C2. so that it can work in any harsh enviroment like moisture etc. make:-L&T/conserve/schmeder/Aarmation 1 No. 3 ii) Main incomer MCCB of suitable capacity of L&T/schmeder/ABB/ Siemens make on the coming feeder for pumping set confirming to BIS-2516-1985 (Latest edition) 1 No 3 (iii) LED Three phase indicating lamps complete with logged switch for indivisual motore confrming to BIS 3452 (Part I & II) latest with up to date amendments 1 No. 3(iv) LED On/Off Lincommer MCCB with proper short circuit capablility for both the starter make L&T/schmeder/ABB (1 No) 3(v) On/Off & Trip indicator and push button, control and power wiring Power capacitor, cooling fan 230 VAC control terminal, Buss Bar i.e. Bolt insulator etc. (1 No ) selector switch for Auto and Manual oparation 1 No. 3(vi) Input Choke of required HP for Energy saving variable frequency starter which should be installed at the input of Energy saving variable frequency starter, so that there whould be proper protection in case of any voltage surge and distortons 2 No. 3(vii) ControlTransformer Make Surge supressor device with isolating MCCB to circunate the power surges due to lightening and system surges 1 No. 3(viii) Power and control Wiring and Busbar 1 No. 3(ix) Installation, commissining and Software Development 1 No. 3(x) Surge supressor device with isolating MCCB toeleminate the power surge due to lightening and system surge 1 No. 3 (xi) power quality monitoring & controling relay with control contactor to safeguard electronic & electric elements 1 No. 3 (xii) Insdependent Control Panel with stiwth Fuse Unit and Fuses to Suitable Amperage to eliminate the Kit Kat fuses of HPSEB Make: Aarmaton/Siemens/Schnieder/L&T 1 No

1

-

-

... More
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make of cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 12(a)+ surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump class of valve shall be ASA 600.

2

-

-

... More
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make of suitable size Cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangements and size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 12(a)+ surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump class of valve shall be ASA 600.

2

-

-

... More
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make of suitable size Cast steel double flanged swing check type reflux valve confirming to API standard with up to date ammendments for R/main as mentioned in item No. 12 (c) for withstanding nominal seat pressure as per item No. 12(a) + surge pressure.The size of reflux valve shall be equal to size of Rising main and the same shall be provided with suitable bye pass arrangements.class of valve shall be ASA 600 and shall be of 100 mm dia meter.

1

-

-

... More
Supply & fixing at site of Leader / KSB/ Kirloskar make cast iron double flanged sluice valve ( in case suction is +ve) for suction pipehaving size one or two size larger than suction size of pump such that velocity of flow in suction pipe is not more than 3.00 mtr/sec and conforming to BIS standards with up to date ammendments. class of valve shall be PN 1.60.

2

-

-

... More
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ICC/EICO/National /IEC make from meter of HPSEB to circuite breaker & from circuite breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.

10

-

-

... More
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.

30

-

-

... More
Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).

2

-

-

... More
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc.conforming to BIS 3624-1987 or latest with up to date ammendments.

2

-

-

... More
P/F double flanged suction, delivery pipe & common header of MSERW pipe Grade- X42 considering site requirements, NPSH reauired & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 12 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump Thickness of MSERW pipe 100 mm dia. shall be 5.60 mm with flanged joint of FT- 34.

1

-

-

... More
Pumping Machinery 2nd Stage

-

-

-

... More
Supply, erection, testing & commissioning of horizontal spindle, horzontal split casing radial split single /multistage centrifugal pumps of standard make such as KSB/ Mather & Platt/ Jyoti/ Kiroskar /Beaconweir/ BS & BE or any other reputed make conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to handel clear water having characteristics as mentioned below in ltem no 18(A), with impelleres,casing ring priming funnels & shaft sleeves of bronze , shaft of steel of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel/ Mild steel to BHEL/ Kirlokar/ NGEF/Crompton/Siemen /jyoti/GEC make slip ring /squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below i/c the cost of all the accessories in all leads and lifts & carriage at the site sites as per direction of Engineer-in - charge. :- (Note:- Tender to be called for per set not for per HP rate)

2

-

-

... More
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 745 mtr

-

-

-

... More
Capacity (in LPS) 3.32 LPS

-

-

-

... More
Dia of R/Main (in mm) 80 MM

-

-

-

... More
Length of rising main (in mtr.) 1600 metres

-

-

-

... More
2X60 HP = 120 HP

-

-

-

... More
Supply, installation, Testing and Commissioning of Fully Autometic LT Panel for centrifugal pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opening door type switch board with copper insulated wiring suitable to operate 2 No. pump of rating suitable HP automatically through variable Frenqency Drive Starter. Starter should be capable to handle all rth faults like short circuit, over current. under current, over voltage, under voltage, dry pump protection. It should get on and off command automatically from PLC and HMI. Monitoring and controlling of Pump running and trippng status should be monitored and controlled remotely through IOT enabled device. Access shoild be given to 3 users. Reputed make. i) Energy saving variable freqency drive starter of suitable HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It should be cable to control the frequecy of pumps through out the opration and also should be cabable to maintain the power factor of the system within acceptable limits. It should be able to withstand ambient temprature 50 Degree ceicius without derating and have conformal coating class 3C2. so that it can work in any harsh enviroment like moisture etc. make:-L&T/conserve/schmeder/Aarmation 1 No. 3 ii) Main incomer MCCB of suitable capacity of L&T/schmeder/ABB/ Siemens make on the coming feeder for pumping set confirming to BIS-2516-1985 (Latest edition) 1 No 3 (iii) LED Three phase indicating lamps complete with logged switch for indivisual motore confrming to BIS 3452 (Part I & II) latest with up to date amendments 1 No. 3(iv) LED On/Off Lincommer MCCB with proper short circuit capablility for both the starter make L&T/schmeder/ABB (1 No) 3(v) On/Off & Trip indicator and push button, control and power wiring Power capacitor, cooling fan 230 VAC control terminal, Buss Bar i.e. Bolt insulator etc. (1 No ) selector switch for Auto and Manual oparation 1 No. 3(vi) Input Choke of required HP for Energy saving variable frequency starter which should be installed at the input of Energy saving variable frequency starter, so that there whould be proper protection in case of any voltage surge and distortons 2 No. 3(vii) Control Transformer Make Surge supressor device with isolating MCCB to circunate the power surges due to lightening and system surges 1 No. 3(viii) Power and control Wiring and Busbar 1 No. 3(ix) Installation, commissining and Software Development 1 No. 3(x) Surge supressor device with isolating MCCB toeleminate the power surge due to lightening and system surge 1 No. 3 (xi) power quality monitoring & controling relay with control contactor to safeguard electronic & electric elements 1 No. 3 (xii) Insdependent Control Panel with stiwth Fuse Unit and Fuses to Suitable Amperage to eliminate the Kit Kat fuses of HPSEB Make: Aarmaton/Siemens/Schnieder/L&T 1 No

1

-

-

... More
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make of cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 18(a)+ surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump class of valve shall be ASA 600.

2

-

-

... More
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make of suitable size Cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangements and size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 18(a)+ surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump class of valve shall be ASA 600.

2

-

-

... More
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / KSB make of suitable size Cast steel double flanged swing check type reflux valve confirming to API standard with up to date ammendments for R/main as mentioned in item No. 18 (c) for withstanding nominal seat pressure as per item No. 18(a) + surge pressure.The size of reflux valve shall be equal to size of Rising main and the same shall be provided with suitable bye pass arrangements.class of valve shall be ASA 600 and shall be of 80 mm dia meter.

1

-

-

... More
Supply & fixing at site of Leader / KSB/ Kirloskar make cast iron double flanged sluice valve ( in case suction is +ve) for suction pipehaving size one or two size larger than suction size of pump such that velocity of flow in suction pipe is not more than 3.00 mtr/sec and conforming to BIS standards with up to date ammendments. class of valve shall be PN 1.60.

2

-

-

... More
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ICC/EICO/National /IEC make from meter of HPSEB to circuite breaker & from circuite breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.

10

-

-

... More
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.

30

-

-

... More
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.

1

-

-

... More
Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ ager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).

2

-

-

... More
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc.conforming to BIS 3624-1987 or latest with up to date ammendments.

2

-

-

... More
P/F double flanged suction, delivery pipe & common header of MSERW pipe Grade- X42 considering site requirements, NPSH reauired & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 18 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump Thickness of MSERW pipe 80mm dia. shall be 5.50 mm with flanged joint of FT- 38.

1

-

-

... More
Rising Main & Distribution System

-

-

-

... More
Excavation in drain and channels etc. in earth work for pipes up to all depths in all classification of earthwork such as pick work, jumper work, saturated soil including bailing or pumping out water, blasting soft/hard rock or chiseling soft/hard rock where blasting is prohbited in all lifts including jungle clearance required, trimming & dressing of sides, leveling of beds to ciorrect grade including shoring/struting, planking, timbering & dewatering where required stacking the useable/unuseasble material/soil seperately & after laying, jointing & testing of pipes, returning the useable soil in trenches in 15 cm with in all leads & lifts including restoration of un-metalled surfaces to its original condition& including with in all leads & lifts as per direction of the Engineer-in-Charge.

2027.06

-

-

... More
Providing, laying, testing & commissioning at site in trenches bevelled ended MSERW pipe of Grade X-42 and Grade B or its equivalent Grades conforming to IS/ ISO 3183-2017 latest with upto date amendements having wall thickness as specified below & capable of withstanding required test pressure as prescribed in IS/ISO code, in random lenghts of 5.5 to 6.5 mtr. The pipes ends shall be bevelled suitable for butt welding including the cost of jointing with butt welding conforming to IS 816-1969 or latest as applicable ends with upto date amendments (leak proof) in three layers at site of work with welding rods of Advani/oeriliken make /IST marked (welded rods 3mm to 4mm) and all allied accessories whatever required for welding at site, tail pieces, tees, bends and other specials manufactured from parent pipes as applicable to the particular each & of approved specification as per site conditions and cutting of pipes wherever required as per site requirement including carriage in all leads and lifts and as directed by Engineer-in-charge. The pipe shall haves zinc coating inside & out side conforming to IS-4736-1986 or latest with upto date amendment & shall be engaged with MSERW pipe grade X-42/Grade A. The laying shall conform to BIS 5822-1970 or latest with upto date amendments to the entire satisfaction of Engineer-in-charge (Earth work & cost of MS Flanges after 90 meter lengh shall be measured & paid for separately) including all leads, lifts and carriage of material at site as per direction and to the entire satisfaction of the Engineer-in charge.

-

-

-

... More
1st Stage

-

-

-

... More
Dia Grade RD to RD wall thickness

-

-

-

... More
100mm X-42 0 180 5.60

180

-

-

... More
100mm X-42 180 450 5.20

270

-

-

... More
100mm X-42 450 810 4.40

360

-

-

... More
100mm B 810 1260 4.40

450

-

-

... More
2nd Stage

-

-

-

... More
80mm X-42 0 450 5.50

450

-

-

... More
80mm X-42 450 720 4.80

270

-

-

... More
80mm X-42 720 1260 4.40

540

-

-

... More
Laying, jointing, testing & commissioning at site in trenches following plain ended GMS pipes of heavy/medium grade as under conforming to IS/ ISO 1239 (part -I) 1990 or latest with upto date amendements capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipes ends shall be bevelled suitable for butt welding including the cost of jointing with butt welding conforming to IS 816-1969 or latest as applicable (leak proof) in three layers at site of work with welding rods of standard make and all allied accessories whatever required for welding at site, tail pieces, tees, bends manufactured from parent pipes as applicable to the particular reach & of approved specification as per site conditions and cutting of pipes etc. and cutting of pipes whatever required as per site requirement including carriage all lifts as directed by the Engineer incharge (Earth work shall be measured and paid for separately).

-

-

-

... More
Booster Stage

-

-

-

... More
Dia RD to RD wall thickness Grade

-

-

-

... More
100mm 0 30 4.50 GI (M)

30

-

-

... More
1st Stage

-

-

-

... More
100mm 1260 1530 5.40 GI (H)

270

-

-

... More
100mm 1530 1800 4.50 GI (M)

270

-

-

... More
2nd Stage

-

-

-

... More
80mm 1260 1440 4.80 GI (H)

180

-

-

... More
80mm 1440 1600 4.00 GI (M)

160

-

-

... More
Providing welding and fixing M.S plate flanges of following dia (nominal bore) of following flanges Table conforming to IS 6392-1971 or latest with upto date amendments to MSERW/G.I. pipe after every 90 metres or as per site requirement including cutting of pipes wherever required welding in three layers (leak proof) conforming to specifications as prescribed in relevent IS code i.e IS 816-1969 or latest as applicable with upto date amendments with nuts, bolts & washers and specials etc. fonforming to IS 1963 or latest with upto date amendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticrossive paints complete in all respect in all leads lifts and carriage of material at site and as directed by the Engineer-in-charge.

-

-

-

... More
Booster Stage

-

-

-

... More
Dia RD to RD Length F.T.

-

-

-

... More
100mm 0 30 30 5

1

-

-

... More
1st Stage

-

-

-

... More
100mm 0 450 450 34

5

-

-

... More
100mm 450 1350 900 28

10

-

-

... More
100mm 1350 1710 360 17

4

-

-

... More
100mm 1710 1800 90 5

1

-

-

... More
2nd Stage

-

-

-

... More
80mm 0 360 360 38

4

-

-

... More
80mm 360 990 630 34

7

-

-

... More
80mm 990 1350 360 28

4

-

-

... More
80mm 1350 1530 180 17

2

-

-

... More
80mm 1530 1600 90 5

1

-

-

... More
DISTRIBUTION SYSTEM

-

-

-

... More
Laying, jointing, testing and commissioning in trenches galvanised mild steel tube of following dia including providing and fixing tube fittings such as reducer increasers, sockets, union,tees,bends etc. where ever required (earth work in trenches to be measured and paid for separately) and as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts.

-

-

-

... More
32 mm dia.(Light)

700

-

-

... More
40 mm dia.(Light)

2300

-

-

... More
50 mm dia.(Light)

1150

-

-

... More
80 mm dia.(Light)

2700

-

-

... More
Providing and fixing full way gun metal gate valve as per IS :780-1984 class-1 with hand wheel of following dia. including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.

-

-

-

... More
32mm dia.

3

-

-

... More
40mm dia.

4

-

-

... More
50mm dia.

5

-

-

... More
80mm dia.

3

-

-

... More
Excavation in foundation and trenches in all type of soil such as pickwork jumper work Kankar, moorum, shingles including decomposed soft and hard rock etcupto all heights stacking the excavated earth not more than 3mtrs clear from the edge of excavation and then returning the stacked soil in 15cm layers when required into plinths sides of foundations etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus excavated earth in all leads and lifts as per the direction of Engineer in-charge.

353.83

-

-

... More
Providing and laying cement concrete 1:4:8(1cement:4approved sand:8app.graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth and as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts.

12.02

-

-

... More
Providing and laying cement concrete 1:3:6(1cement:3approved sand:6app.graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth and as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts.

5.96

-

-

... More
Providing and laying cement concrete 1:1.5:3(1cement:1.5approved sand:3approved graded stone aggregate 20mm nominal size)and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:-

-

-

-

... More
Foundation and plinth including entire carriage of material upto all leads and lifts.

27.37

-

-

... More
Wall (any thickness but not less than 0.1m thickness) attached pillasters,buttresses plinth and string courses etc. from top to foundation level upto floor two level and as per the direction of Engineer-in-charge.including entire carriage ofmaterial upto all leads and lifts.

61.92

-

-

... More
in suspended floors, roofs, landings, shelves and their supports balconies beams, girders bressumers and cantilevers upto floor two level in all heights and depths includiing all leads lifts and carriage of material at site and as directed by the Engineer Incharge.

7.24

-

-

... More
Arch upto floor two level

14.44

-

-

... More
Providing and laying cement concrete 1:6:12 ( 1 cement : 6 sand :12 graded stone aggregate 40 mm nominal size ) and curring complete excluding cost of form work in foundation and plinth in all heights and depths including all leads lifts and carrige of material at site and as directed by the Engineer Incharge.

25.06

-

-

... More
Filling in plinth with sand under floor including watering, ramming, consolidating and dressing complete as per the direction of Engineer-in-charge .including entire carriage of material upto all leads and lifts.

12.28

-

-

... More
Providing and laying reinforced cement concrete work 1:2:4 ( 1 cement :2 sand :4 graded stone aggregate 20 mm nominal size ) excluding cost of form work and reinforcement for reinforced concrete work:-

-

-

-

... More
in suspended floors, roofs, landings, shelves and their supports balconies beams, girders bressumers and cantilevers upto floor two level in all heights and depths includiing all leads lifts and carriage of material at site and as directed by the Engineer Incharge.

20.36

-

-

... More
In lintel, beams, girders, bressumeres and cantilever up to floor two level including all leads , lifts and carriage of material and as directed by the Engineer Incharge.

2.12

-

-

... More
In foundation, footing, base of column and like & mass concrete including all leads , lifts and carriage of material and as directed by the Engineer Incharge.

4.26

-

-

... More
Providing & laying CC 1:2:4 1cement:2 sand 4 graded aggregates 20mm nominal size curing complete excluding cost of form work in foundation & plinth.

4

-

-

... More
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish. Including centring,shuttering strutting and propping etc. with wooden battens and ballies height of propping and centring below supporting floor to ceiling not exceeding 4mtrs and removal of the same for insitu reinforced concrete and plain concrete work in:-

-

-

-

... More
Vertical surface such as wall of (any thickness) partition and the like including attached pillaster buttresses plinth and string courses and like and as per the direction of Engineer-in-charge .including entire carriage of material upto all leads and lifts.

657.52

-

-

... More
Flat surfaces such as soffits of suspended floors, roofs, landings and the like, floors etc., up to 200mm in thickness.

104.14

-

-

... More
Sides & soffits of beams,beam haunchings, catilevers, bressumers & lintels not exceeding 1.00 mtr.depth in all ht.from floor.

5.66

-

-

... More
Providing form work of ordinary timber planking so as to give a rough finish Including centring,shuttering strutting and propping etc. with wooden battens and ballies height of propping and centring below supporting floor to ceiling not exceeding 4mtrs and removal of the same for insitu reinforced concrete and plain concrete work:-

-

-

-

... More
in Arches beyond 6 mtr span including entire carriage of material upto all leads and lifts as per direction of Engineer-in-charge.

144.43

-

-

... More
Providing in RCC work smooth finishing of the exposed surface with cement mortar 1:3 ( 1 cement :3 sand ) .

589.66

-

-

... More
Providing tor steel reinforcement for RCC work including bending,binding and placing in position complete upto floor two level.as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts.

11742.07

-

-

... More
Laying and jointing in trenches galvanised mild steel steel tubes(light grade ) tube fittings( earth work in trenches to be measured and paid for separately) for scoure, inlet, outlet and over flow pipe with all leads and lifts.

-

-

-

... More
100mm dia

42

-

-

... More
125mm dia

36

-

-

... More
Providing and fixing double flanged cast iron sluice valve of following dia. of leader/Kirlosker/Bir/Kartar make as per IS 780 class PN-1.6 and capable of with standing the normal seat pressure as per IS 5312-1884 P-1 and as per direction of the Engineer- in-charge upto all lead and lifts.

-

-

-

... More
100mm dia

6

-

-

... More
125mm dia

4

-

-

... More
Prov. & fixing SFRC Man hole cover with frame having frames size of 500 mm internal dia.should not be less than 58 kg including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.

4

-

-

... More
Prov. & fixing SFRC Man hole cover with frame having frames size of 560 mm internal dia.should not be less than 100 kg including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.

4

-

-

... More
Constructing chamber for sluice valve, with CI surface box 100 mm top dia.,160 mm bottom dia. & 180 mm deep(inside) with chained lid RCC top 1:2:4 mix (1 cement :2 sand :4 graded stone aggregate 20 mm nominal size) 100mm thick foundation concrete 1:5:10 mix (1cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) & inside plastering with cement mortor 1 :3 (1 cement : 3 sand) finished with a floating coat of neat cement i/c curing complete. 600 x 600 x 750 mm inside size With 150 mm thick walls of RCC 1:2 :4 (1 cement :2 sand :4 graded stone aggregate 20mm nominal size) complete with form work & reinforcement with 6 mm bars at not exceeding 150 mm centres both ways.

8

-

-

... More
Brick work using common burnt clay building bricks in super structure in all height and depth in Cement mortar 1:6 (1 cement : 6 sand) with in all leads , lifts and carriage of material at site and as directed by the Engineer Incharge.1st class bricks.

40.76

-

-

... More
Brick work using common burnt clay building bricks in foundation & plinth in Cement mortar 1:6 (1 cement : 6 sand) with in all leads , lifts and carriage of material at site and as directed by the Engineer Incharge. 2nd class brick

32.6

-

-

... More
Brick work using common burnt clay building bricks in foundation & plinth in Cement mortar 1:6 (1 cement : 6 sand) with in all leads , lifts and carriage of material at site and as directed by the Engineer Incharge. 1st class bricks.

27.04

-

-

... More
Half brick work using common burnt clay building bricks in super structure in Cement mortar 1:4 (1 cement : 4sand) with in all leads , lifts and carriage of material at site and as directed by the Engineer Incharge. 2nd class bricks.

116.42

-

-

... More
Providing and fixing pressed steel door frames manufacuted from commercial M.S Seats of 1.25mm thickness including hinges jump lock jamb lead and it required angle threashald of MS angle 50x25mm or less tie of 1.25mm pressed MS welded or rigidly fixed together by mechanical means adjustable longs with split and tails to each jamb including steel butt hinges 2.5mm thick with guards, lock strick plate and shock as specified and applying a coat of steel primer after pretreatment of surface as directed by Engineer-in-Charge.

133.42

-

-

... More
Providing and fixing 1mm thick M.S.sheet garrage shutters with frame of 40mmx40mmx6mm angle iron 3.15mm M.S.gusset plates at junctions and corners all necessary fittings complete including applying a priming coat of red lead paint : Using M.S. angles 40mmx40mmx6mm for diagonal braces including entire carriage of material upto all leads and lifts.

23.98

-

-

... More
15 mm cement plaster in single coat on fair side of brick/stone masonry wall for interior plastering upto floor two level including arrieses internal rounded angles chambers and rounded angles not exceeding 80 mm in grith and finished even and smooth in cement mortar 1:6 (1 cement : 6 sand) including all leads , lifts and carriage of material at site and as directed by the Enginner Incharge.

361.82

-

-

... More
Pointing on brick work with cement mortar 1:3 ( 1 cement : 3 sand)including carriage of material in all leads & lifts

312.04

-

-

... More
6mm thick cement plaster to ceiling in cement mortar 1:3 ( 1 cement : 3 sand) including all leads , lifts and carriage of material at site and as directed by the Enginner Incharge.

104.14

-

-

... More
White washing with lime on undecorated wall surfaces (Two coats) to give an even shade including throughly brooming the surface to remove all dirt dust and other foreign matter including all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.

449.22

-

-

... More
Finishing Wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surfaces (two coat ) to give an even shade including throughly brushing the surface to remove all dirt and remains of loosepowderd material.

673.86

-

-

... More
Cement concrete flooring 1:2:4 ( 1cement : sand : 4 graded stone aggregate 20mm nominal size) and laid in one layer finished with a floating coat of neat cement, 50mm thick including all leads lifts and carriage of material at site as as per the direction of the Engineer incharge.

36.94

-

-

... More
Applying a priming coat with ready mixed red oxide zinc chlorate primer of approved brand and manufacture on steel galvanised iron/steel works complete in all respect including all leads, lifts and carriage of material and as directed by the Engineer Incharge.

46.66

-

-

... More
Painting two coat (excluding priming coat) on new steel and steel based surfaces with ready mixed red oxide zinc chromate primer of approved brand to give an even shade including clearing of all dirt, dust and other foreign matter sand paper and stopping:- with ready mixed paint other than white, including all leads, lifts and carriage of materials and as directed by the Engineer Incharge.

23.98

-

-

... More
Providing and fixing MS grills of required pattern in wooden frames of windows etc with M.S flasts squar or rounded bars with rounded handed bolts and nuts or by screws plain grills. including all leads, lifts and carriage of material and as directed by the Engineer Incharge.

202.4

-

-

... More
Providing and fixing MS sliding door bolts with nuts and serews complete as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts..:-250x16mm

6

-

-

... More
Providing and fixing MS tower bolts (barrel type) with nuts and serews complete as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts:-

-

-

-

... More
200mmX10mm

40

-

-

... More
Providing and fixing anodized MS handles with necessary screws complete as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts..:-

-

-

-

... More
125mm dia

40

-

-

... More
Providing and fixing M.S.fan clamp(Type-I) of 16mm dial M.S. Bar bent to shape with hooked ends in RCC. Slab during laying including painting the exposed portion of loop all as per standard design complete.

4

-

-

... More
Providing and fixing 40x3mm flat iron hold fast 40cm long including fixing to frames 10cm diameter bolts and nuts and wooden plug and embedded in cement concrete block 30x30x15cm in C.C. 1:3:6 ( 1 cement : 3 sand : 6 graded stone aggragate 20mm niminal size) including all leads, lifts and carriage of material and as directed by the Engineer Incharge.

58

-

-

... More
Providing plinth protection 50mm thick in cement concrete 1:3:6 (1cement;3 sand:6 graded stone stone 20mm size) including all leads lifts and carriage of material at site and as directed by the Engineer Incharge.

33.54

-

-

... More
Steel work welded in built up sections, trusses, framed work, including cutting, hoisting, fixing in position and applying a priming coat of red lead paint in gratings, framed guard bars, ladders railling, brackets and similar works with all leads and lifts.

11.65

-

-

... More
Providing and fixing water level indicator (Manual) of supeerior quality complete in all respect as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts..

2

-

-

... More
Providing and fixing on wall face cast iron rain water pipe 100 mm dia.including fitting and joint with spun yarn and cement mortar 1:2 (1 cement : 2 sand) including clams complete as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts..

16

-

-

... More
Providing & fixing galvanized Barbed wire (IS 278-1982 type-1) weighing 9.38 kg per 100 mt. as per the direction of Engineer-in-charge .including entire carriage of material upto all leads and lifts.

120

-

-

... More
Wiring for light point / Fan point / Exhaust fan point / call bell point with 1.5 Sq.mm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVc conduit and earthing the light point with 1.5sq.mm HRFRLS/PVC insulated single core copper conductor cable complete in all respect. "Group-C".

30

-

-

... More
Wiring for 3pin 5/6 amp socket outlet point on switch board in (surface /recessed PVC wiring system) and 5/6 amp tumbler piono type switch earthing the 3 pin painting etc as required with in all leads & lifts complete.

6

-

-

... More
Wiring of power plug with (2x4 Sq.mm.) PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. 4 Sq.mm HRFRLS/PVC insulated single core copper conductor cable for earthing as required including carriage of material with in all leads & lifts complete.

70

-

-

... More
Wiring the light plug with (2x1.5 Sq.mm.) PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. 1.5Sq.mm HRFRLS/PVC insulated single core copper conductor cable for earthing as required including carriage of material with in all leads & lifts complete.

150

-

-

... More
Wiring for Circuit /sub main with 2x10 Sq.mm. size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required including carriage of material with in all leads & lifts complete.

30

-

-

... More
Supplying and fixing metal box of 180 x 100 x 60mm deep (Nominal size) on surface/ recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 3 pim 15/16 amps socketoutlet and 15/16 amp piano type switch connections painting etc. as required.

6

-

-

... More
Supplying and erection of floor mounted fixed type metal frame work/boards of welded construction for switch gear mounting fabricated with MS angle iron (50mm x 50mm x6mm thick) of suitable dimensions with supporting members grouted 23 cm underground and frame work covered with 3mm thick MS sheet from top to a given height , with MS angle iron/50mmx50mmx6mm thick welded on the back and grouted into the back wall complete with painting and bonding to the existing earth as required with in all leads & lifts complete.

0.96

-

-

... More
Supplying and fixing of following way single pole and netural sheet steel MCB distribution board 240 volts on surface/recessed completed with tinned, copper bus bar, wireset, netural link, earth bar, din bar detachable gland plate , blanking plate, cable, identification labels inter - connections, phosphatized and powder painted including earthing etc. as required with in all leads & lifts complete. Double door-8 way.

6

-

-

... More
Supplying and fixing 63 Amp rating, double pole, 240 volts, isolater in the exisitng MCB DB complete with connections , testing and commissioning etc. as required with in all leads & lifts complete. Cat. A

6

-

-

... More
Supplying and fixing 63 amp rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB) having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required with in all leads & lifts complete. Cat. A

4

-

-

... More
Supplying and fixing 5 Amps to 32 Amps rating 240 Volts "L" series miniature circuit breaker of single poles in the exixting MCB DB complete with connections, testing and commissioning etc. as required within all leads and lifts.

6

-

-

... More
Providing, installing, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required with in all leads & lifts complete. Ceiling fan 1200 mm sweep, Category-A.

6

-

-

... More
Providing, installing, testing and commissioning of prewired flourscent tube fitting 1x40 watt box type Cat A i.e. Bajaj make complete with ballast starter and capactors but excluding flourscent tube rod, suitable to operate on 240 volts single phase A.C. supply directly on surface with copper wiring as required complete as per direction of the Engineer-in-charge.

8

-

-

... More
Earthing with G.I. pipe earth, pipe 4.5 length, 40 mm dia including accessories and providing masonry enclousres with cover plate having locking arrangement and watering pipe etc. ( but without charcal coke and salt) complete as required including carriage of materials within all leads and lifts.

4

-

-

... More
Extra using salt and charcoal for pipe earth electrode as required.

4

-

-

... More
Supplying and laying 6 SWG G.I. wire on surface /recess for loop earthing as required complete as per direction of the Engineer-in-charge.

80

-

-

... More
Providing, fixing & testing Street Light Fixture 40watts 4 feet long complete with choke starter i/c connections complete as required complete as per direction of the Engineer-in-charge.

8

-

-

... More
Providing, Fixing, testing & commissioning of Gaseous type chlorination system of 500 grams per hour capacity complete in all respects.as per the direction of Engineer-in-charge .including entire carriage of material upto all leads and lifts.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.