Himachal Pradesh Irrigation And Public Health Department Tender
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender
Civil And Construction
Eprocure
Opening Date19 Sep 2023
Closing Date27 Sep 2023
Tender Amount₹ 3,66,86,481
Costs
EMD
₹ 3,99,365Document Cost
₹ 2,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_HPIPH_79029_1Bid Award Id
ViewTender No
EE-JSV-HMR-CB-tenders-2022-23Tender Authority
Himachal Pradesh Irrigation And Public Health Department ViewPurchaser Address
-Website
http://http://hpiph.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
1. 0.5 kg. per hour capacity:
1
-
-
2. 2 kgs. per hour capacity:
1
-
-
Providing, fixing, testing & commissioning of new chlorine gas filled cylinders (100 kgs. capacity) as per IS 3224 -1979 duly certified by Petroleum & Explosive Safety Organisation. Govt. of India.
6
-
-
Providing, fixing, testing & commissioning of ABB / Hussaini / Siemens make Chlorine gas Leak detector with hooter & alarm, complete in all respects.
1
-
-
Providing, fixing, testing & commissioning of Arka / Swan / Jumo make Real Time Water Quality Monitoring System Parameters: Turbidity, Chlorine, PH & TDS.
- Display screen: 7 inch LCD Touch screen
- Complete digital automated sensors
- With inbuilt By-pass assembly setup
- With solenoid valve and timer for user selectable test interval
- Material: reinforced ABS/ MS box powder coated
- Protection grade IP65
- With Over Voltage, Current and surge protection
- Optional IOT device and cloud server provision (SIM/ WIFI based)
- Auto calibration function using touch screen display
- Cooling exhaust fan for electronics
- Communication: RS485 modbus RTU
- Power Supply: AC100-240V
• Turbidity Digital Sensor
Measuring Range : 0 to 400 NTU 0.1~60℃
Light Source: 660nm laser light source
Display Accuracy: 0.001~40NTU is ±2% of reading.
Operating Environment: 0~50℃
Flow Rate: 100ml/min≤x≤500ml/min
Discharge port: 1/2NPT
Main Material : Body: ABS+Nylon
• Digital chlorine Sensor
Measuring range: 0-20.00ppm
Resolution: 0.01
pH-dependence
pH range: 6-8
1
-
-
Response time: T90 30s
drinking water
Not resistant to surfactants
• PH digital Sensor
PH: 0-14pH
Working temperature: 0.0~50.0℃
Resolution: 0.01pH/0.1℃
Accuracy: ±0.02pH
Working pressure: 0~2Bar
Material: PPS
• TDS digital sensor
Measuring Range(EC)
Automatic switch:
0~200.0μS/cm
0~2000μS/cm
0.00~10.00mS/cm
Operating Environment: 0~50℃
Resolution: 0.01 μS/cm 0.1℃
Local Cloud Server
IOT based: GSM and WIFI module Online software with GUI interface
Cloud storage With online and historical data view and monitoring With SMS alerts.
-
-
-
Providing, fixing, testing & commissioning of Siemens / Danfoss / ABB make 40 HP VFD (Variable Frequency Drive) Panels which includes MCCB incomer, semiconductor fuses, Control transformer, isolation Contactor with Aluminum Bus Bar. VFD Should have Quick setup Personal menu with Sleep function open loop, broken belt function, flow compensation, initial ramp (2 Step ramp), low flow monitoring, check valve ramp, run permissive, motor preheat, hand-auto function, pump cascade controller, dry pump detection, real time clock function, energy meter and logging, preventive maintenance function, payback indication, language changer, smart logic controller, electronic by pass function Aqua Drive complete in all respect including Earthing as per the satisfaction of Engineer-in-charge.
4
-
-
Providing, fixing, testing & commissioning of Prefabricated PUF insulated structure of Size: 12’ x 8’ x 9’ single side slope which includes:
• 50 mm wall PUF panel with PPGI sheet on both sides.
• 30 / 60mm roof PUF panel with PPGI sheet on both sides.
• PPGI Flashing (Edge cover, U channel & corners).
• PUF panel door (2x1m) & window (1x1)
• Hardware & accessories etc.
1
-
-
LWSS Noughi Bhumpal (1.80 MLD capacity)
-
-
-
Designing, providing, fixing, testing and commissioning of Hanovia / Trojan / Alfa /equivalent make UV plants for 40m3/hr. capacity. The UV plant shall have reactor, cabinet housing, cabinet cooling, treatment chamber, electrical panel, temperature safety control, lamp out alert, UV radiometer along with UV monitoring system and UV monitoring readout panel. UV system for disinfection shall utilize high purity quartz sleeves and high output Amalgam UV lamps. UV Reactor MOC will be SS316L. The electrical control system should utilize high frequency electronic ballasts and provide efficiency of more than 90%. The reactor vessel shall utilize internal baffles to ensure turbulent and plug flow. The UV intensity monitoring system shall be designed in accordance with the DVGW W294 standard. The sensor shall be of dry type and removable without system shutdown. The quartz cleaning mechanism shall include an Auto wiper system with approved Viton and rotary seals. All safety equipments required for UV system shall be provided by contractor. Civil / electrical works, i.e. 10 meters MS pipe DN100mm, 4 Nos. DI Sluice Valves DN100mm (PN16), 2 Nos. DI Sluice Valve DN150mm (PN16), 2 Nos. CI Y type Strainers DN150mm, 10 Nos. DI D/F Bends (DN100mm), 12 Nos. MS Flanges with rubber Gaskets (DN100mm), 150 kgs. MS Nuts & Bolts, 50 meters 3 core insulated copper wire / cable (2.5mm), cable tray, welding for construction of base for installation of UV Plants using steel fixtures & fittings (MS Angle, Plate cutting, etc.), 1 No. Servo 5 KVA air cooled Stabilizer, 50 Hz frequency, including repair & maintenance of UV plants for a period of 12 months complete in all respects & as per satisfaction of Engineer-in-charge.
2
-
-
Design parameters of UV plants :-
-
-
-
Basic Flow Rate 40 m3/hr UV Dose 40,000 uW-sec/cm2 UV Transmission 90%
Electrical Voltage 220 - 240V / 50 - 60Hz Maximum Power Consumption 1234 W Number of Lamps 3
Control Panel Rating IP54 (indoor use only) MOC M.S. Max. Lamp Cable Length 4.5 meters.
Reactor MOC Stainless Steel 316L End Connections (ASA 150 RF Flanges) 4” Max. Operating Pressure 120 psi Max. Operating Temperature 45 degrees C Max. Sanitization Temperature 85 degrees C (lamps turned off) Quartz Jacket MOC High Purity Quartz (UVT 95%)
Controller Features UV Intensity Meter with Intelli Dose Yes UV Intensity Sensor (with Isolated Design) Yes 4 - 20mA Output Signal Yes RS485 / MODBUS Interface Yes Built In Data Logging (3,000 records) Yes Remote Lamp / On-Off (hardwire or MODBUS) Yes Control Panel Temperature Control Yes (with automatic over temperature shutoff) Reactor Temperature Control Yes (with automatic over temperature shutoff) (with automatic over temperature shutoff) Automatic wiping on low UV Yes Lamp Replacement Reminder with pre-alert. Yes Control Panel Safety Interlock Switch
Standard Features Lamp Replacement Reminder Yes Lamp Failure Indication (with Alarm) Yes UV intensity meter with IntelliDose Yes Sanitary TC End Connections Available. Automatic Wiper System Yes
-
-
-
Providing, fixing, testing and commissioning of Jesco / Enchlor / DeNora make gaseous type full vacuum Chlorination system consisting of Vacuum regulator, Safety valve, Measuring glass, Non return valve, Ejector, PE tubing, Spanner & Cylinder opening keys. The Gas chlorination plant should confirm to Indian Explosive Rules 1983 & Latest / amended rules by issued by Petroleum & Explosive Safety Organisation. (Govt. of India).Pipes, fittings & fixtures, i.e. ISI marked CPVC pipes & fittings (1”), ball valves, washers, clamps, conduit pipes, etc. required for installation of gas chlorination plant as per site condition, complete in all respects.
-
-
-
0.5 kgs. per hour capacity:
1
-
-
2 kgs. per hour capacity:
1
-
-
Providing, fixing, testing & commissioning of new chlorine gas filled cylinders (100 kgs. capacity) as per IS 3224 -1979 duly certified by Petroleum & Explosive Safety Organisation. Govt. of India.
6
-
-
Providing, fixing, testing & commissioning of ABB / Hussaini / Siemens make Chlorine gas Leak detector with hooter & alarm, complete in all respects.
1
-
-
Providing, fixing, testing & commissioning of Prefabricated PUF insulated structure of Size: 12’ x 10’ x 10’ single side slope which includes:
• 50 mm wall PUF panel with PPGI sheet on both sides.
• 30 / 60mm roof PUF panel with PPGI sheet on both sides.
• PPGI Flashing (Edge cover, U channel & corners).
• PUF panel door (2x1m) & window (1x1)
• Hardware & accessories etc.
1
-
-
LWSS Rail (1.20 MLD capacity)
-
-
-
Designing, providing, fixing, testing and commissioning of Hanovia / Trojan / Alfa/equivalent make UV plants for 47m3/hr. capacity. The UV plant shall have reactor, cabinet housing, cabinet cooling, treatment chamber, electrical panel, temperature safety control, lamp out alert, UV radiometer along with UV monitoring system and UV monitoring readout panel. UV system for disinfection shall utilize high purity quartz sleeves and high output Amalgam UV lamps. UV Reactor MOC will be SS316L. The electrical control system should utilize high frequency electronic ballasts and provide efficiency of more than 90%. The reactor vessel shall utilize internal baffles to ensure turbulent and plug flow. The UV intensity monitoring system shall be designed in accordance with the DVGW W294 standard. The sensor shall be of dry type and removable without system shutdown. The quartz cleaning mechanism shall include an Auto wiper system with approved Viton and rotary seals. All safety equipments required for UV system shall be provided by contractor. Civil / electrical works, i.e. 5 meters MS pipe DN150mm, 3 Nos. DI Sluice Valves DN150mm (PN16), 1 No. CI Y type Strainers DN150mm, 4 Nos. DI D/F Bends (DN150mm), 4 Nos. MS Flanges with rubber Gaskets (DN150mm), 90 kgs. MS Nuts & Bolts, 50 meters 3 core insulated copper wire / cable (2.5mm), cable tray, welding for construction of base for installation of UV Plants using steel fixtures & fittings (MS Angle, Plate cutting, etc.), 1 No. Servo 5 KVA air cooled Stabilizer, 50 Hz frequency, including repair & maintenance of UV plants for a period of 12 months complete in all respects & as per satisfaction of Engineer-in-charge.
1
-
-
Design parameters of UV plants :-
-
-
-
Basic Flow Rate 47 m3/hr UV Dose 40,000 uW-sec/cm2 UV Transmission 90%
Electrical Voltage 220 - 240V / 50 - 60Hz Maximum Power Consumption 1595 W Number of Lamps 4
Control Panel Rating IP54 (indoor use only) MOC M.S. Max. Lamp Cable Length 4.5 meters.
Reactor MOC Stainless Steel 316L End Connections (ASA 150 RF Flanges) 6” Max. Operating Pressure 120 psi Max. Operating Temperature 45 degrees C Max. Sanitization Temperature 85 degrees C (lamps turned off) Quartz Jacket MOC High Purity Quartz (UVT 95%)
Controller Features
UV Intensity Meter with Intelli Dose Yes UV Intensity Sensor (with Isolated Design) Yes 4 - 20mA Output Signal Yes RS485 / MODBUS Interface Yes Built In Data Logging (3,000 records) Yes Remote Lamp / On-Off (hardwire or MODBUS) Yes Control Panel Temperature Control Yes (with automatic over temperature shutoff) Reactor Temperature Control Yes (with automatic over temperature shutoff) (with automatic over temperature shutoff) Automatic wiping on low UV Yes Lamp Replacement Reminder with pre-alert. Yes Control Panel Safety Interlock Switch Yes
Standard Features Lamp Replacement Reminder Yes Lamp Failure Indication (with Alarm) Yes UV intensity meter with IntelliDose Yes Sanitary TC End Connections Available. Automatic Wiper System Yes
-
-
-
Providing, fixing, testing and commissioning of Jesco / Enchlor / DeNora make gaseous type full vacuum Chlorination system consisting of Vacuum regulator, Safety valve, Measuring glass, Non return valve, Ejector, PE tubing, Spanner & Cylinder opening keys. The Gas chlorination plant should confirm to Indian Explosive Rules 1983 & Latest / amended rules by issued by Petroleum & Explosive Safety Organisation. (Govt. of India).Pipes, fittings & fixtures, i.e. ISI marked CPVC pipes & fittings (1”), ball valves, washers, clamps, conduit pipes, etc. required for installation of gas chlorination plant as per site condition, complete in all respects.
-
-
-
1. 2 kgs. per hour capacity:
1
-
-
Providing, fixing, testing & commissioning of new chlorine gas filled cylinders (100 kgs. capacity) as per IS 3224 -1979 duly certified by Petroleum & Explosive Safety Organisation. Govt. of India.
6
-
-
Providing, fixing, testing & commissioning of ABB / Hussaini / Siemens make Chlorine gas Leak detector with hooter & alarm, complete in all respects.
1
-
-
Providing, fixing, testing & commissioning of Prefabricated PUF insulated structure of Size: 10’ x 6’ x 10’ single side slope which includes:
• 50 mm wall PUF panel with PPGI sheet on both sides.
• 30 / 60mm roof PUF panel with PPGI sheet on both sides.
• PPGI Flashing (Edge cover, U channel & corners).
• PUF panel door (2x1m) & window (1x1)
• Hardware & accessories etc.
1
-
-
LWSS Amblehar Bhabrian (3.50 MLD capcity)
-
-
-
Designing, providing, fixing, testing and commissioning of Hanovia / Trojan / Alfa/equivalent make UV plants for 67m3/hr. capacity. The UV plant shall have reactor, cabinet housing, cabinet cooling, treatment chamber, electrical panel, temperature safety control, lamp out alert, UV radiometer along with UV monitoring system and UV monitoring readout panel. UV system for disinfection shall utilize high purity quartz sleeves and high output Amalgam UV lamps. UV Reactor MOC will be SS316L. The electrical control system should utilize high frequency electronic ballasts and provide efficiency of more than 90%. The reactor vessel shall utilize internal baffles to ensure turbulent and plug flow. The UV intensity monitoring system shall be designed in accordance with the DVGW W294 standard. The sensor shall be of dry type and removable without system shutdown. The quartz cleaning mechanism shall include an Auto wiper system with approved Viton and rotary seals. All safety equipments required for UV system shall be provided by contractor. Civil / electrical works, i.e. 8 meters MS pipe DN150mm, 3 Nos. DI Sluice Valves DN150mm (PN16), 1 No. CI Y type Strainers DN150mm, 4 Nos. DI D/F Bends (DN150mm), 4 Nos. MS Flanges with rubber Gaskets (DN150mm), 90 kgs. MS Nuts & Bolts, 50 meters 3 core insulated copper wire / cable (2.5mm), cable tray, welding for construction of base for installation of UV Plants using steel fixtures & fittings (MS Angle, Plate cutting, etc.), 1 No. Servo 5 KVA air cooled Stabilizer, 50 Hz frequency, including repair & maintenance of UV plants for a period of 12 months complete in all respects & as per satisfaction of Engineer-in-charge.
1
-
-
Design parameters of UV plants :-
-
-
-
Basic Flow Rate 67 m3/hr UV Dose 40,000 uW-sec/cm2 UV Transmission 90%
Electrical Voltage 220 - 240V / 50 - 60Hz Maximum Power Consumption 1956 W Number of Lamps 5
Control Panel Rating IP54 (indoor use only) MOC M.S. Max. Lamp Cable Length 4.5 meters.
Reactor MOC Stainless Steel 316L End Connections (ASA 150 RF Flanges) 6” Max. Operating Pressure 120 psi Max. Operating Temperature 45 degrees C Max. Sanitization Temperature 85 degrees C (lamps turned off) Quartz Jacket MOC High Purity Quartz (UVT 95%)
Controller Features
UV Intensity Meter with Intelli Dose Yes UV Intensity Sensor (with Isolated Design) Yes 4 - 20mA Output Signal Yes RS485 / MODBUS Interface Yes Built In Data Logging (3,000 records) Yes Remote Lamp / On-Off (hardwire or MODBUS) Yes Control Panel Temperature Control Yes (with automatic over temperature shutoff) Reactor Temperature Control Yes (with automatic over temperature shutoff) (with automatic over temperature shutoff) Automatic wiping on low UV Yes Lamp Replacement Reminder with pre-alert. Yes Control Panel Safety Interlock Switch Yes
Standard Features Lamp Replacement Reminder Yes Lamp Failure Indication (with Alarm) Yes UV intensity meter with IntelliDose Yes Sanitary TC End Connections Available. Automatic Wiper System Yes
-
-
-
Designing, providing, fixing, testing and commissioning of Hanovia / Trojan / Alfa make UV plants for 110m3/hr. capacity. The UV plant shall have reactor, cabinet housing, cabinet cooling, treatment chamber, electrical panel, temperature safety control, lamp out alert, UV radiometer along with UV monitoring system and UV monitoring readout panel. UV system for disinfection shall utilize high purity quartz sleeves and high output Amalgam UV lamps. UV Reactor MOC will be SS316L. The electrical control system should utilize high frequency electronic ballasts and provide efficiency of more than 90%. The reactor vessel shall utilize internal baffles to ensure turbulent and plug flow. The UV intensity monitoring system shall be designed in accordance with the DVGW W294 standard. The sensor shall be of dry type and removable without system shutdown. The quartz cleaning mechanism shall include an Auto wiper system with approved Viton and rotary seals. All safety equipments required for UV system shall be provided by contractor. Civil / electrical works, i.e. 6 meters MS pipe DN150mm, 3 Nos. DI Sluice Valves DN150mm (PN16), 1 No. CI Y type Strainers DN150mm, 4 Nos. DI D/F Bends (DN150mm), 4 Nos. MS Flanges with rubber Gaskets (DN150mm), 90 kgs. MS Nuts & Bolts, 50 meters 3 core insulated copper wire / cable (2.5mm), cable tray, welding for construction of base for installation of UV Plants using steel fixtures & fittings (MS Angle, Plate cutting, etc.), 1 No. Servo 10 KVA air cooled Stabilizer, 50 Hz frequency, including repair & maintenance of UV plants for a period of 12 months complete in all respects & as per satisfaction of Engineer-in-charge.
1
-
-
Design parameters of UV plants :-
-
-
-
Basic Flow Rate 110 m3/hr UV Dose 40,000 uW-sec/cm2 UV Transmission 90%
Electrical Voltage 220 - 240V / 50 - 60Hz Maximum Power Consumption 3039 W Number of Lamps 8
Control Panel Rating IP54 (indoor use only) MOC M.S. Max. Lamp Cable Length 4.5 meters.
Reactor MOC Stainless Steel 316L End Connections (ASA 150 RF Flanges) 6” Max. Operating Pressure 120 psi Max. Operating Temperature 45 degrees C Max. Sanitization Temperature 85 degrees C (lamps turned off) Quartz Jacket MOC High Purity Quartz (UVT 95%)
Controller Features UV Intensity Meter with Intelli Dose Yes UV Intensity Sensor (with Isolated Design) Yes 4 - 20mA Output Signal Yes RS485 / MODBUS Interface Yes Built In Data Logging (3,000 records) Yes Remote Lamp / On-Off (hardwire or MODBUS) Yes Control Panel Temperature Control Yes (with automatic over temperature shutoff) Reactor Temperature Control Yes (with automatic over temperature shutoff) (with automatic over temperature shutoff) Automatic wiping on low UV Yes Lamp Replacement Reminder with pre-alert. Yes Control Panel Safety Interlock Switch Yes
Standard Features Lamp Replacement Reminder Yes Lamp Failure Indication (with Alarm) Yes UV intensity meter with IntelliDose Yes Sanitary TC End Connections Available. Automatic Wiper System Yes
-
-
-
Providing, fixing, testing and commissioning of Jesco / Enchlor / DeNora make gaseous type full vacuum Chlorination system consisting of Vacuum regulator, Safety valve, Measuring glass, Non return valve, Ejector, PE tubing, Spanner & Cylinder opening keys. The Gas chlorination plant should confirm to Indian Explosive Rules 1983 & Latest / amended rules by issued by Petroleum & Explosive Safety Organisation. (Govt. of India).Pipes, fittings & fixtures, i.e. ISI marked CPVC pipes & fittings (1”), ball valves, washers, clamps, conduit pipes, etc. required for installation of gas chlorination plant as per site condition, complete in all respects.
-
-
-
2 kgs. per hour capacity:
2
-
-
Providing, fixing, testing & commissioning of new chlorine gas filled cylinders (100 kgs. capacity) as per IS 3224 -1979 duly certified by Petroleum & Explosive Safety Organisation. Govt. of India.
12
-
-
Providing, fixing, testing & commissioning of ABB / Hussaini / Siemens make Chlorine gas Leak detector with hooter & alarm, complete in all respects.
1
-
-
Providing, fixing, testing & commissioning of Prefabricated PUF insulated structure of Size: 12’ x 10’ x 10’ single side slope which includes:
• 50 mm wall PUF panel with PPGI sheet on both sides.
• 30 / 60mm roof PUF panel with PPGI sheet on both sides.
• PPGI Flashing (Edge cover, U channel & corners).
• PUF panel door (2x1m) & window (1x1)
• Hardware & accessories etc.
1
-
-
LWSS Kohla Kaloor (1.60MLD)
-
-
-
Designing, providing, fixing, testing and commissioning of Hanovia / Trojan / Alfa/equivalent make UV plants for 65m3/hr. capacity. The UV plant shall have reactor, cabinet housing, cabinet cooling, treatment chamber, electrical panel, temperature safety control, lamp out alert, UV radiometer along with UV monitoring system and UV monitoring readout panel. UV system for disinfection shall utilize high purity quartz sleeves and high output Amalgam UV lamps. UV Reactor MOC will be SS316L. The electrical control system should utilize high frequency electronic ballasts and provide efficiency of more than 90%. The reactor vessel shall utilize internal baffles to ensure turbulent and plug flow. The UV intensity monitoring system shall be designed in accordance with the DVGW W294 standard. The sensor shall be of dry type and removable without system shutdown. The quartz cleaning mechanism shall include an Auto wiper system with approved Viton and rotary seals. All safety equipments required for UV system shall be provided by contractor. Civil / electrical works, i.e. 6 meters MS pipe DN150mm, 3 Nos. DI Sluice Valves DN150mm (PN16), 1 No. CI Y type Strainers DN150mm, 4 Nos. DI D/F Bends (DN150mm), 4 Nos. MS Flanges with rubber Gaskets (DN150mm), 90 kgs. MS Nuts & Bolts, 50 meters 3 core insulated copper wire / cable (2.5mm), cable tray, welding for construction of base for installation of UV Plants using steel fixtures & fittings (MS Angle, Plate cutting, etc.), 1 No. Servo 5 KVA air cooled Stabilizer, 50 Hz frequency, including repair & maintenance of UV plants for a period of 12 months complete in all respects & as per satisfaction of Engineer-in-charge.
1
-
-
Design parameters of UV plants :-
-
-
-
Basic Flow Rate 65 m3/hr UV Dose 40,000 uW-sec/cm2 UV Transmission 90%
Electrical Voltage 220 - 240V / 50 - 60Hz Maximum Power Consumption 1956 W Number of Lamps 5
Control Panel Rating IP54 (indoor use only) MOC M.S. Max. Lamp Cable Length 4.5 meters.
Reactor MOC Stainless Steel 316L End Connections (ASA 150 RF Flanges) 6” Max. Operating Pressure 120 psi Max. Operating Temperature 45 degrees C Max. Sanitization Temperature 85 degrees C (lamps turned off) Quartz Jacket MOC High Purity Quartz (UVT 95%)
Controller Features UV Intensity Meter with Intelli Dose Yes UV Intensity Sensor (with Isolated Design) Yes 4 - 20mA Output Signal Yes RS485 / MODBUS Interface Yes Built In Data Logging (3,000 records)Yes Remote Lamp / On-Off (hardwire or MODBUS) Yes Control Panel Temperature Control Yes (with automatic over temperature shutoff) Reactor Temperature Control Yes (with automatic over temperature shutoff) (with automatic over temperature shutoff) Automatic wiping on low UV Yes Lamp Replacement Reminder with pre-alert. Yes Control Panel Safety Interlock Switch Yes
Standard Features Lamp Replacement Reminder Yes Lamp Failure Indication (with Alarm) Yes UV intensity meter with IntelliDose Yes Sanitary TC End Connections Available. Automatic Wiper System Yes
-
-
-
Providing, fixing, testing and commissioning of Jesco / Enchlor / DeNora make gaseous type full vacuum Chlorination system consisting of Vacuum regulator, Safety valve, Measuring glass, Non return valve, Ejector, PE tubing, Spanner & Cylinder opening keys. The Gas chlorination plant should confirm to Indian Explosive Rules 1983 & Latest / amended rules by issued by Petroleum & Explosive Safety Organisation. (Govt. of India).Pipes, fittings & fixtures, i.e. ISI marked CPVC pipes & fittings (1”), ball valves, washers, clamps, conduit pipes, etc. required for installation of gas chlorination plant as per site condition, complete in all respects.
-
-
-
1. 2 kgs. per hour capacity:
1
-
-
Providing, fixing, testing & commissioning of new chlorine gas filled cylinders (100 kgs. capacity) as per IS 3224 -1979 duly certified by Petroleum & Explosive Safety Organisation. Govt. of India.
6
-
-
Providing, fixing, testing & commissioning of ABB / Hussaini / Siemens make Chlorine gas Leak detector with hooter & alarm, complete in all respects.
1
-
-
Providing, fixing, testing & commissioning of Prefabricated PUF insulated structure of Size: 10’ x 6’ x 10’ single side slope which includes:
• 50 mm wall PUF panel with PPGI sheet on both sides.
• 30 / 60mm roof PUF panel with PPGI sheet on both sides.
• PPGI Flashing (Edge cover, U channel & corners).
• PUF panel door (2x1m) & window (1x1)
• Hardware & accessories etc.
1
-
-