Himachal Pradesh Agriculture Development Society Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Himachal Pradesh Agriculture Development Society Tender

Works
Civil And Construction
Irrigation Work
Eprocure
Opening Date19 Sep 2022
Closing Date11 Oct 2022
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in position cement concrete 1:4:8 (1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of centering and shuttering complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

21.29

-

-

... More
Providing and laying in position cement concrete 1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of centering and shuttering complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

1.48

-

-

... More
Providing and laying in position cement concrete 1:2:4 (1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and curing complete in :

-

-

-

... More
Foundation & plinth excluding the cost of centering, shuttering & reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

3.58

-

-

... More
In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto all level, excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

9.83

-

-

... More
Providing and laying in position reinforced cement concrete 1:1.5:3 (1cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size) and curing complete in :

-

-

-

... More
Foundation & plinth excluding the cost of centering, shuttering & reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

2.82

-

-

... More
In beams, suspended floors, roofs having slope landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto all level, excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

2.56

-

-

... More
In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto all level, excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

17.78

-

-

... More
Providing form work with steel plates 3.15mm.thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centering and shuttering including strutting, propping etc. and removal of form work for:

-

-

-

... More
Foundations, footings, bases for columns, mass concrete complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

28.8

-

-

... More
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

340.64

-

-

... More
Suspended floors, roofs, landings, balconies and access platform complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

14.42

-

-

... More
Edges of slabs and breaks in floors and walls complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

20.44

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

0.68

-

-

... More
Filling in plinth with sand under floor including watering, ramming, consolidating and dressing complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

0.73

-

-

... More
Boulder / Stone filling under floor consolidating & dressing etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

1.46

-

-

... More
Providing Mild steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

1458.05

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

1588.46

-

-

... More
Providing & laying Damp Proof Course 40mm thick with cement concrete 1:2:4 (1 cement:2sand:4 graded stone aggregate 10 mm nominal size) & curing complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

2.69

-

-

... More
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

2.69

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in all shapes and sizes Cement mortar 1:6 (1 cement : 6 coarse sand) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

7.58

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes Cement mortar 1:6 (1 cement : 6 coarse sand) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

7.35

-

-

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

1.81

-

-

... More
6 mm cement plaster in cement mortar 1:3 ( 1 cement : 3 fine sand) in ceiling complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

13.52

-

-

... More
15 mm cement plaster on the rough side of brick wall in cement mortar 1:4 (1 cement: 4 Coarse sand) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

67.36

-

-

... More
Providing and laying cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

9.28

-

-

... More
Providing and fixing 1mm thick M.S. sheet garrage door with frame and diagonal braces or 40x40x6 mm angle iron 3.15 mm M.S. gusset plates at junctions and corner 25 mm dia pully 40x40x6 mm angle and T-iron guide at the top and bottom respectively, including applying a primer coat of red lead paint complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

6.12

-

-

... More
Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden/ steel frames of windows and clerestory windows (M.S. grill) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

21.36

-

-

... More
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge. .

14

-

-

... More
Providing and fixing ISI marked oxidised M.S. sliding door bolts (250 x 16 mm) with nuts and screws etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

1

-

-

... More
Providing and fixing ISI marked oxidised M.S. tower bolt (250 x 10 mm) black finish, (Barrel type) with necessary screws etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

6

-

-

... More
Providing and fixing ISI marked oxidised M.S. handles (125 mm) conforming to IS:4992 with necessary screws etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

67

-

-

... More
Finishing with epoxy paint (two or more coats) at all locations prepared on steel work and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

73.99

-

-

... More
White washing with lime to give an even shade New Work (three or more coats) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

43.4

-

-

... More
Finishing walls with water proofing cement paint of required shade: New Work (Two or more costs applied @ 3.84 kg/10sqm) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

37.48

-

-

... More
Providing and fixing M.S fan clamp type 1 of 16 mm dia M.S bar bent to shape with hooked ends in R.C.C slab during laying including painting the exposed portion of loop, all as per standard design complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

1

-

-

... More
Providing plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

4.52

-

-

... More
Providing and fixing on wall face C.I.rain water pipe of 110 mm dia including fitting the joints with spun yarn and cement mortar 1:2 (1 cement :2sand) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

6.3

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion single pushfit coupler complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.

2

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Bend 87.5° complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.

2

-

-

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. 110 mm dia complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.

6

-

-

... More
Providing, laying, jointing, commissioning and testing in trenches (to level or grade) GMS tubes confirming to IS : 1239 : 2004 of 150 mm dia, medium class with all necessary fittings conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. including flushing , cleaning and hydraulic testing of pipe complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.

30

-

-

... More
Providing, laying, jointing, commissioning and testing in trenches (to level or grade) GMS tubes confirming to IS : 1239 : 2004 of 125 mm dia, medium class with all necessary fittings conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. including flushing , cleaning and hydraulic testing of pipe complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.

498

-

-

... More
Providing, laying, jointing, commissioning and testing in trenches (to level or grade) GMS tubes confirming to IS : 1239 : 2004 of 100 mm dia, medium class with all necessary fittings conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. including flushing , cleaning and hydraulic testing of pipe complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.

6

-

-

... More
Providing, laying, jointing, commissioning and testing in trenches (to level or grade) GMS tubes confirming to IS : 1239 : 2004 of 80 mm dia, medium class with all necessary fittings conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. including flushing , cleaning and hydraulic testing of pipe complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.

12

-

-

... More
Providing circumferencial Butt welded joints by electrical arc welding to GMS tubes confirming to IS : 1239 : 2004 of 125 mm dia, welded in requisite numbers of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani Oerlikon (Adore) - Citojet / ESAB make conforming to IS 814-1991, at site of work complete in all respect including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.

82

-

-

... More
Providing, welding and fixing of M.S. flanges @ 1% of joints at suitable reaches, conforming to table 5, 125 mm dia as per IS:6392-1971 (latest with upto date amendments) and welding of MS Flanges with G.I. Pipes/ MSERW pipes in two layers on both faces to make the joint leak proof (the cost of providing and laying of G.I.Pipes/MSERW Pipes to be measured and paid for separately). The welding of flanges should conform to IS 816-1969 with electrode as per IS : 814-1991 and required number of nuts & bolts conforming to IS: 1364. The thickness of gasket not less than 3.00mm conforming to IS : 2712-1998. The work shall be done as per entire satisfaction of Engineer-in-Charge within all leads and lifts.

3

-

-

... More
Providing and fixing CI Sluice Valve of following dai & class of Leader / Kartar / Kirloskar make with MS Flange of Table 5 as per IS 6392-1971 & welding of MS Flanges in two layers on both faces complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

-

-

-

... More
150 mm dia, PN-1.0 (10.2 Kg/cm²)

3

-

-

... More
125 mm dia, PN-1.0 (10.2 Kg/cm²)

2

-

-

... More
100 mm dia, PN-1.0 (10.2 Kg/cm²)

5

-

-

... More
80 mm dia, PN-1.0 (10.2 Kg/cm²)

8

-

-

... More
Providing and fixing CI Non Return Valve 125 mm dia, PN-1.0 (10.2 Kg/cm²) of Leader / Kartar / Kirloskar make with MS Flange of Table 5 as per IS 6392-1971 & welding of MS Flanges in two layers on both faces complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

2

-

-

... More
Providing, laying, jointing, commissioning & testing in trenches HDPE pipes of following diameters & classes as per IS 4984 (1995) and jointing the pipes with push type compression joints by hydraulically operated machines, butt fussion welding & electro fusion welding machines i/c necessary fittings, bends, tees, unions, flanges, collars & reducers etc. confirming to IS 8360 & IS 8008 with latest ammendments & shall be provided as per site conditions. Flanging of the pipes shall be made as & where required. Jointing shall be confirming to IS code 8008 & IS 7634, stub ends will be welded on pipes & MS flange shall be provided with slip on covered by epoxy coating/plastic powder. The flange should be confirm to ANSI B 16.5 with necessary nuts & bolts. All manufacturing maerial used shall be in accordance to IS 4427-2007 (latest revision) with 100 % virigin pre-compounded or natural PE resin. Jointing shall be complete in all respects i/c testing at site upto entire satisfaction of the Engineer-in-Charge.

-

-

-

... More
90 mm dia HDPE pipe (PN 4.0, PE 80)

1193

-

-

... More
110 mm dia HDPE pipe (PN 4.0, PE 80)

1522

-

-

... More
125 mm dia HDPE pipe (PN 4.0, PE 80)

404

-

-

... More
Providing and fixing of 75 mm hydrant with main or submain line including HDPE Riser 75 mm double threaded PN-6.0, 75 mm PP ball valve, bend, male female coupler threaded PN-6.0, service saddle PN-6.0 and elbow bend with steel clamp complete in all respect and jointing by butt fusion process (as per requirement of main & sub main line) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

41

-

-

... More
Providing and fixing of Air Release Valve of 25 mm dia. with service saddle & GI Nipple in distribution system including jointing & fitting complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

7

-

-

... More
Writing new letters and figures of any shade with synthetic enamel black or any other approved colour to give an even shade as per drawings and technical specifications clause 1701 in English and roman, hyphen, commas and the like not to be measured and paid complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

2017.5

-

-

... More
Supply, installation, testing & commissioning of Open Well submersible pumping set of KSB /Calama /SU/ Johnstion make comprising to latest relevant BIS Code. The pump should be fitted with bronze impeller of suitable alloys as per IS 8034-1976 latest suitable for clear water having greased packed bearings and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) of required HP, RPM 2900 of reputed make conforming to IS 9283-1979 latest with upto date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. It should include flow meter, cost of bearing nuts, bolts and pointing etc. and should meet the following requirements. The pumping set should include water level guards i/c cable, erection clamps , cable clips and depth gauge etc. and any other item/ fittings required as per site conditionsThe pumping set should include water level guards i/c cable, erection clamps, cable clips and depth gauge etc. and any other item suitable for operation of pumping machinery. (Note: The bidder is required to fill & upload/submit the bid evaluation sheet for pumping machinery mentioned in the bidding document with the technical proposal)

2

-

-

... More
SITE CONDITIONS:-

-

-

-

... More
Location of site:- Dohgi

-

-

-

... More
The altitude of place in which the motor is intended to work in ordinary service.- 528.10 mtrs.

-

-

-

... More
Humidity:- Humid during rainy season

-

-

-

... More
Nature of atmosphere:- Normal

-

-

-

... More
Detail of quality of water:- Clear water

-

-

-

... More
Water free from sand or not:- Free from sand

-

-

-

... More
Water corrosive or not:- Not corrosive

-

-

-

... More
Turbidity:- Less than 50 ppm

-

-

-

... More
Any other information if required.

-

-

-

... More
OPERATING CONDITIONS

-

-

-

... More
Type of current:- AC. Three phase

-

-

-

... More
Operating frequency:- 50 Hz.

-

-

-

... More
Rated voltage :- 400(+/-) 15% volts.

-

-

-

... More
System of earthing to be adopted :- Double loop earthing as per BIS: 3843-1987 latest with upto date amendments .

-

-

-

... More
Speed of revolution :- To be quoted by tenderer

-

-

-

... More
Direction of rotation:- To be quoted by tenderer

-

-

-

... More
No. of working hours per day:- 20 Hours

-

-

-

... More
The maximum temperature of cooling air and water in the place in which the pump set is intended to work in ordinary service :- Temperature of place to be specified 20°C to 42°C. 

-

-

-

... More
MOTOR

-

-

-

... More
Ref. to BIS code:- BIS 9283-1979 with upto date amendments

-

-

-

... More
Type of enclosure of motor:- As per BIS-4691-1985 (Latest)

-

-

-

... More
Type of duty :- Continuous

-

-

-

... More
Mechanical output in KW:- Suitable for driving submersible pumps required for duties specified against pumps. To avoid overloading of motor a margin of about 15-20% may be kept in the rated output to prime Mover.

-

-

-

... More
Class of insulation:- Class –B

-

-

-

... More
Max. Permissible temp. Rise of motor reqd. if different from that given above:- To be specified by the tenderer.

-

-

-

... More
Particulars of test reqd. & where they are to be conducted:- AS per terms and conditions attached.

-

-

-

... More
Particulars as to whether voltage limiting device will be employed:- Oil immersed star delta starter to be installed between bus bar and motor. Shunt capacitor is also proposed to be installed for improving the power factor at site. Note:- Star delta starter upto 37.5 Kw.

-

-

-

... More
Type of motor:- As per BIS 9283-1979 or latest

-

-

-

... More
Details of shaft extension required

-

-

-

... More
Break way torque in terms of rated load torque and the corresponding break-way starting current which may be taken from the supply with the starting apparatus in circuit:- Break way torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.

-

-

-

... More
Nature of load and any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelerated and No. of starts during a specified period:-To work the pump offered.

-

-

-

... More
Where possible fault capacity of the system to which the motor is connected:- The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations.

-

-

-

... More
PUMPS

-

-

-

... More
Nos. of pumps required:- 2 No.

-

-

-

... More
Spare parts required:- For two years normal maintenance as recommended by manufacturer.

-

-

-

... More
Type of drive:- Electric induction motor.

-

-

-

... More
Optional fittings required

-

-

-

... More
Pump Operating conditions

-

-

-

... More
Discharge: - Total: 10.97 LPS & 5.49 LPS for each set

-

-

-

... More
Total head in meters:- 32.65 meter

-

-

-

... More
Static head :- 27.90 meter

-

-

-

... More
Minimum depth of water in meters

-

-

-

... More
Variation in water level in meters

-

-

-

... More
Ground level to Max. water level (H.F.L) in meters

-

-

-

... More
Ground level to delivery point in meters

-

-

-

... More
Pressure in the suction tank. in meters

-

-

-

... More
Pressure in the delivery tank in meters

-

-

-

... More
Length of rising main:- 150 meter

-

-

-

... More
Dia of rising main:- 125 mm

-

-

-

... More
Turbidity of water than 50 PPM

-

-

-

... More
Drive type :- Electric driven

-

-

-

... More
Operating range :- (-) 15% to (+) 10% of total head at duty point.

-

-

-

... More
Suction/Delivery size of pump:- To be specified by the tenderer.

-

-

-

... More
Efficiency of pump at:- To be specified by the tenderer.

-

-

-

... More
Duty head

-

-

-

... More
(+) 10% head.

-

-

-

... More
(-) 15% head.

-

-

-

... More
Material of construction:- To be specified by the tenderer (manufacturers certificate to be appended)

-

-

-

... More
Provding & fixing of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel board shall be subject to approval of Engineer-in-Charge.

2

-

-

... More
Provding & fixing of Capacitor/ shunt capacitor of Crompton / L&T / Asian make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. of motor offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments .

2

-

-

... More
Provding & fixing of suitable DOL/ Star Delta Starter of L&T /Siemens/ Crompton make as per IS: 8544 (Part-I)-1967 with upto date amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS : 1248 ( P-V ) 1983 with up to date amendments.

2

-

-

... More
Providing ICTP Main Switch with HRC fuses / side handled operated Change over switch of L&T / Crompton / Standard / Havells make for required motor and having capacity 30% extra of the operational rating of motor as per IS: 4064 (Part-II) -1978 latest with up to date amendments.

2

-

-

... More
Provding & fixing of MCB of suitable capacity of Havells/Standard/MDS/Jyoti/Kilburn make on incoming feeder motors with or without initial oil filling as the case may be offered by the tenderer conforming to IS: 2516 (Part-II)-1985 latest with upto date amendments with neutral linked under voltage release.

2

-

-

... More
Provding & fixing of ELCB of Havells/ Standard make as per IS: 2516 (Part-II)-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault.

2

-

-

... More
Provding & fixing of Ammeter AC supply, 125 mm square type auto electric of AE/ L&T Rishab make of suitable capacity for above motor with selector switches conforming to IS-1248 (Part-II) -1983 latest with upto date amendments.

2

-

-

... More
Provding & fixing of Voltmeter AC supply, 125 mm square type auto electric AE/ L&T Rishab make of 0-500 Volts range for above motor with selector switches conforming to IS-1248 (Part-II) -1983 latest with upto date amendments.

2

-

-

... More
Provding & fixing of Voltage Monitor Relay 3 phase of AE/ L&T Rishab make with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference conforming to IS-1248 (Part-II) -1983 latest with upto date amendments.

2

-

-

... More
Provding & fixing of Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutral conforming to BIS: 8084 –1976 and 11353-1985 read with BIS 5578-1985 all latest with upto date amendmentsof suitable rating.

2

-

-

... More
Provding & fixing of 3 phase indicator lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date amendments.

2

-

-

... More
Provding & fixing of 50 mm dial Hour run meter of CEE/NEE/ reputed make of four digit capacity confirming to BIS 722 (latest edition) / recommendations.

2

-

-

... More
Provding & fixing of 100 mm dia circular dial Pressure Gauge of Feibig/ Bourden make 0-16 kg/cm2 range of feibig make with all accessories such as stop cock, copper tubing etc, conforming to BIS: 3624-1987 latest with upto date amendments.

1

-

-

... More
Provding & fixing double flanged cast iron/ cast steel non return valve of Leader /Kirloskar/Kartar make of required dia as per the size of delivery line withstanding nominal seat pressure of PN-1.0 (10.2 Kg/cm²) as per IS 5312-1984 with MS Flange of Table 5 as per IS 6392-1971 & welding of MS Flanges in two layers on both faces complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

2

-

-

... More
Provding & fixing double flanged cast iron/ cast steel sluice valve of Leader /Kirloskar/Kartar of required dia as per the size of delivery line withstanding nominal seat pressure of PN-1.0 (10.2 Kg/cm²) as per IS 780-1964 (Part-I ) with MS Flange of Table 5 as per IS 6392-1971 & welding of MS Flanges in two layers on both faces complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

2

-

-

... More
Providing and laying of copper PVC insulated armoured power cable of suitable size and capacity to motors and all other electrical equipments conforming to BIS 1554 (part-I) –1988 or latest with upto date amendments siemen/closter/ICC make form meter of HPSEB- to MCB and form MCB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply Side - Sutaible Size Motor Side - Sutaible Size

50

-

-

... More
Providing and laying of PVC jointless flat water proof cable as per BIS: 694-1990 latest with upto date amendments suitable for the pump sets offered from MCB to motor including all other electrical equipment/accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced by tender.

50

-

-

... More
Providing and fixing double loop earthing and G.I. plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx6mm G.I. strips & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.

2

-

-

... More
Providing and laying suction/ delivery pipe GMS Tubes (Medium Class) (IS:1239 - 2004) of suitable dia & length jointed with MS flanges of table-5 as per IS: 6392-1971 including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses as per layout drawings approved by Engineer-in-Charge.

1

-

-

... More
Supply, installation, testing & commissioning horizontal spindle, horizontal split casing/end suctions (back full out arrangement) single/ multistage centrifugal pump or combination of pump in series of recommended make such as Mather and Platt/KSB/Kirloskar as per IS-1520-1980 (latest with up to date amendments) read with IS: 9137-1978 or latest edition suitable for lifting clear water for under mentioned characteristics with bronze impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a MS/Cast steel base plate (base plate to be from the manufacturers of the pumping unit only) to ring/ squirrel cage screen protected drip proof induction motor of standard make such as Kirloskar/Crompton/NGEF suitable for operation on 400 (+/-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be at least 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 15% of the duty point head. The motor should be as per IS: 325-1978 with up to date amendments read with IS: 900-1972. It should include flow meter, cost of bearing nuts, bolts and pointing etc. and should meet the following requirements. The pumping set should include water level guards i/c cable, erection clamps , cable clips and depth gauge etc. and any other item/ fittings required as per site conditions and suitable for operation of pumping machinery on data given below:- (Note: The rate quoted by the bidder should be inclusive of all the items as listed below and the bidder is required to fill & upload/submit the bid evaluation sheet for pumping machinery mentioned in the bidding document with the technical proposal)

1

-

-

... More
Specification

-

-

-

... More
(a)Pumps:

-

-

-

... More
(i) Make

-

-

-

... More
(ii) Model

-

-

-

... More
(iii) No's of Stages

-

-

-

... More
(iv) Material manufacures certificate to be appended Performances

-

-

-

... More
(a) Head (H)

-

-

-

... More
(b) Discharge (Q)

-

-

-

... More
(c) BHP absorbed

-

-

-

... More
(d) Efficiency (n)

-

-

-

... More
(e) NPSH (K)

-

-

-

... More
(b) Motors: (Specification)

-

-

-

... More
(i) Make.

-

-

-

... More
(ii) Model

-

-

-

... More
(iii) Motor rating (KW)

-

-

-

... More
(iv) Speed

-

-

-

... More
(v) Insulation

-

-

-

... More
(c) Coupling:

-

-

-

... More
(d) Base plate.

-

-

-

... More
Discharge (Q) : - 9.97 LPS

-

-

-

... More
Total dynamic head : 30.05 Mtr.

-

-

-

... More
(a) LWL (h) : 553.39 Mtr.

-

-

-

... More
(b) Shaft level : 553.25 Mtr.

-

-

-

... More
(c ) Level at discharge point : 576.90 Mtr.

-

-

-

... More
(d) Suction lift : - 0.14 Mtr.

-

-

-

... More
(e) Residual head : 1.00 Mtr.

-

-

-

... More
(f) Static head : 23.65 Mtr.

-

-

-

... More
(g) Rising Main :

-

-

-

... More
(i) Length 342.00 Mtr.

-

-

-

... More
(ii) Dia. : 125 mm

-

-

-

... More
(iii) Pumping Hours : 20 Hours

-

-

-

... More
Provding & fixing of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel board shall be subject to approval of Engineer-in-Charge.

1

-

-

... More
Provding & fixing of Capacitor/ shunt capacitor of Crompton / L&T / Asian make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. of motor offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments .

1

-

-

... More
Provding & fixing of suitable DOL/ Star Delta Starter of L&T /Siemens/ Crompton make as per IS: 8544 (Part-I)-1967 with upto date amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS : 1248 ( P-V ) 1983 with up to date amendments.

1

-

-

... More
Providing ICTP Main Switch with HRC fuses / side handled operated Change over switch of L&T / Crompton / Standard / Havells make for required motor and having capacity 30% extra of the operational rating of motor as per IS: 4064 (Part-II) -1978 latest with up to date amendments.

1

-

-

... More
Provding & fixing of MCB of suitable capacity of Havells/Standard/MDS/Jyoti/Kilburn make on incoming feeder motors with or without initial oil filling as the case may be offered by the tenderer conforming to IS: 2516 (Part-II)-1985 latest with upto date amendments with neutral linked under voltage release.

1

-

-

... More
Provding & fixing of ELCB of Havells/ Standard make as per IS: 2516 (Part-II)-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault.

1

-

-

... More
Provding & fixing of Ammeter AC supply, 125 mm square type auto electric of AE/ L&T Rishab make of suitable capacity for above motor with selector switches conforming to IS-1248 (Part-II) -1983 latest with upto date amendments.

1

-

-

... More
Provding & fixing of Voltmeter AC supply, 125 mm square type auto electric AE/ L&T Rishab make of 0-500 Volts range for above motor with selector switches conforming to IS-1248 (Part-II) -1983 latest with upto date amendments.

1

-

-

... More
Provding & fixing of Voltage Monitor Relay 3 phase of AE/ L&T Rishab make with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference conforming to IS-1248 (Part-II) -1983 latest with upto date amendments.

1

-

-

... More
Provding & fixing of Power Factor Meter of AE/ L&T Rishab make as per IS: 1248 (Part-V) -1983 with upto date amendments and of suitable rating.

1

-

-

... More
Provding & fixing of Frequency Meter of AE/ L&T Rishab make as per IS: 1248 (Part-IV) -1983 with upto date amendments and of suitable rating.

1

-

-

... More
Provding & fixing of Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutral conforming to BIS: 8084 –1976 and 11353-1985 read with BIS 5578-1985 all latest with upto date amendmentsof suitable rating.

1

-

-

... More
Provding & fixing of 3 phase indicator lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date amendments.

1

-

-

... More
Provding & fixing of 50 mm dial Hour run meter of CEE/NEE/ reputed make of four digit capacity confirming to BIS 722 (latest edition) / recommendations.

1

-

-

... More
Provding & fixing of 100 mm dia circular dial Pressure Gauge of Feibig/ Bourden make 0-16 kg/cm2 range of feibig make with all accessories such as stop cock, copper tubing etc, conforming to BIS: 3624-1987 latest with upto date amendments.

1

-

-

... More
Provding & flaying of anti vibration pads confirming to BIS 6337-1971 or latest with upto date ammendments of suitable size of above machinery.

1

-

-

... More
Providing and laying of copper PVC insulated armoured power cable of suitable size and capacity to motors and all other electrical equipments conforming to BIS 1554 (part-I) –1988 or latest with upto date amendments siemen/closter/ICC make form meter of HPSEB- to MCB and form MCB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply Side - Sutaible Size Motor Side - Sutaible Size

15

-

-

... More
Providing and fixing double loop earthing and G.I. plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx6mm G.I. strips & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.

1

-

-

... More
Provding & fixing double flanged cast iron/ cast steel sluice valve of Leader /Kirloskar/Kartar of required dia as per the size of delivery line withstanding nominal seat pressure of PN-1.0 (10.2 Kg/cm²) as per IS 780-1964 (Part-I ) with MS Flange of Table 5 as per IS 6392-1971 & welding of MS Flanges in two layers on both faces complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

1

-

-

... More
Provding & fixing double flanged cast iron/ cast steel non return valve of Leader /Kirloskar/Kartar make of required dia as per the size of delivery line withstanding nominal seat pressure of PN-1.0 (10.2 Kg/cm²) as per IS 5312-1984 with MS Flange of Table 5 as per IS 6392-1971 & welding of MS Flanges in two layers on both faces complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

1

-

-

... More
Providing double flanged Cast iron foot valve of Leader /Kirloskar/Kartar make of required dia as per the size of suction pipe withstanding nominal seat pressure of PN-1.0 (10.2 Kg/cm²) as per IS 4038-1986 & IS –1414/ API-600(class, ASA-150) with MS Flange of Table 5 as per IS 6392-1971 & welding of MS Flanges in two layers on both faces complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

1

-

-

... More
Providing and fixing double flanged G.M.S. piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983, tees, bends, tapers & any other fitting required as per site conditions. The pipes shall be as per relevant IS Code 1239: 2004 and to withstand 1.5 times total head stipulated under item No. Ist. G.M.S.TUBE Conforming to IS: 1239 – 1990 (part – I) (Medium class) flanged with M.S. flanges of Table-5.

-

-

-

... More
Suction pipe

6

-

-

... More
Delivery pipe

6

-

-

... More
And will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.

-

-

-

... More
Providing & erection of electricity system in the pump house with one fan, two CFL (1 inside & 1 outside), one 5amp socket, one 16 Amp. socket inner side of pump house complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.