Himachal Pradesh Horticultural Produce Marketing And Processing Corporation Limited Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Himachal Pradesh Horticultural Produce Marketing And Processing Corporation Limited - HPMC Tender

Works
Civil And Construction
Coronavirus COVID 19
Eprocure
Opening Date8 Apr 2021
Closing Date15 Jun 2021
Tender Amount₹ 6,85,49,670 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Insulation PUR Sheets for floor insulation in CA Chamber + Corridor ( Ante Room ) as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 3.2 comprising • Two layers each 50 mm thick ( Total 100 mm thick) • Thermal conductivity (λ) of the insulating material is at least 0.023 W/(m·K) • Completed with 50 micron thick Aluminum sheet / 250 Micron PVC Sheet as vapour barrier and blown bitumen of 85/25 grade to be spread @ 1.5 kg/ m2 on each surface ( total 4 surfaces i.e. 6 kg/ m2 . Top layer of minimum 2.4 mm thick bituminized tar-felt.

320

-

-

... More
Insulation PUR panels (As per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 3.1 for External walls , Internal wall (partition wall) and Ceiling

-

-

-

... More
100 mm thick PUR Panel for external wall , Partition wall , ceiling of CA CS Chambers and plateform in Corridor ( Ante room )

1050

-

-

... More
Panel fixing accessories as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 3.1 & 3.1.1 comprising comprising double edge profiles floor mounting oxidation free material (plastic , SS or panel cladding sheet 0.8 mm thick, Suitable ceiling mounting oxidation free material for carrying ceiling panels and silicon sealent etc. as required

800

-

-

... More
Gastight coating and flees as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 3.3 and in accordance with ISO 6949 regulations • All corner connections (floor-wall, wall-wall, wall-ceiling) within the cells • All panel joints • Panel joints above evaporator • Connections around passages, door and hatch Parts to be treated are cleaned, degreased and primed. Two layers of coating and elastic fleece are used for corner seals and flat seals. The coating used will remain free of fungal development for a period of at least 10 years. Guarantee for period of 5 years for gastightness a maximum leakage size of 0.20 cm2 / 100 m3; testmethod described

1

-

-

... More
Wall protection a s per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 3.6 and in accordance with ISO 6949 regulations applied less than 120 mm from wall. Posts of stainless steel U-100 at a foot plate 80/150/10 mm, height 500 mm, galvanised, column spacing approx. 1.500 m, with adhesive anchors fixed in the floor. Beam in stainless steel profiling at least 180 (height)/10 mm

110

-

-

... More
CA doors of size 2500 mm (W) x 3500 mm (H) with lockable control window of size 600 mm (W) x 800 mm (H) complete in all respect as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 3.4

5

-

-

... More
Manual Horizontal Sliding Doors of sizes as per drawings complete in all respect as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 3.5 for corridor ( Ante Room )

2

-

-

... More
Anti-collision bollards of steel to reject collision loads in the reveal area of the CA and Ante room doors, consisting of an approx. 140 mm thick steel pipe, approx. 100 cm high, with foot plate doweled to the concrete floors. Material: hot-dip galvanised. ( 2 Piece / door)-a s per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement in Item no. 3.4 (o) and in accordance with ISO 6949 regulations

12

-

-

... More
REFRIGERATION PLANT as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement -4A

-

-

-

... More
Refrigeration compressor of capacity 50 KW at minus 10 deg C SST and 35 deg C DST complete with accessories as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 4.1.1 D

3

-

-

... More
VFD Drive for one compressor only - as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 4.1.1 C & D

1

-

-

... More
Oil Separator (one per compressor) - as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 4.1.1 D • Collection • Filtering • Levelling

3

-

-

... More
Air colled Condenser (capacity at 10 K, Tc 35 deg C) 170 KW including fans , valves fittings, controls and electricals etc. as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 4.1.1 E

1

-

-

... More
HP Ammonia receiver suitable refrigeration capacity as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 4.1.1 E including safety relief valves , gauge glass ,air release valves ,controls and water sprinkler etc.

1

-

-

... More
Heat exchangers/cooler units - Single sided blow through type, ceiling supported as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 4.1.1 B of following sizes/ capacities

-

-

-

... More
CapacityHeat exchangers/cooler for room storage capacity : 50MT room • Cooling capacity at -8/8K TV1 - 25 KW

5

-

-

... More
Constructive material to fix coolers to the ceiling . Fastening material (threaded ends) shall be of stainless steel -as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 4.1.1 B

1

-

-

... More
Curtain left and right next to cooler as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 4.1.1 B and shall include: • Length under cooler 1,200 mm • Strong material (f.e. PVC Bisonyl tarp) • Constructed (weighted) that suction by airflow is prevented.

5

-

-

... More
Ammonia and Propylene Glycol valves, controls, fittings, nut bolt and gasket -as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 4.1.1 A & I

1

-

-

... More
MS "C" pipes and fittings for refrigerant piping-as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 4.1.1 A & H

1

-

-

... More
GI "B" class pipes & fittings for water piping -as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 4.1.1 A & H

1

-

-

... More
Propylene Glycol PHE Chiller of capacity 100 KW -as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 4.1.1 G (b) , complete with controls & accumulator

1

-

-

... More
Propylene Glycol Storage Tank with two compartment of suitable storage/ operational capacity at 100 KW refrigeration load -as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 4.1.1 G(c)

1

-

-

... More
Propylene Glycol Primary Pumps ( 1 W +1 S)- as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 4.1.1 G (d)

2

-

-

... More
Propylene Glycol Secondary Pumps ( 1 W +1 S)-as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 4.1.1 G(d)

2

-

-

... More
VFD Drive for Primary & Secondary Glycol Pump- as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 4.1.1 G(d)

4

-

-

... More
Propylene Glycol Flow control valves including pumps for each chambers-as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 4.1.1 A (cc) , 4.1.1 G ( e)

5

-

-

... More
Refrigerating PLC control system -as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item 4.1 & 4.1.1 I ( g ), Complete with PLC and PC, LCD monitor & Windows 12 PRO including printer and internet connection ,Software licence

1

-

-

... More
Temperature Sensors PT1000 , at least 4 temperature sensors / CA chambers -as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item 4.1.1 - I (h)

5

-

-

... More
Defrost water measuring system as per detailed given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no.4.1.1 -I (j-viii)

5

-

-

... More
Electrical Panel with Automatic power factor controller Panel ( APFC Panel with adequate capacitors to maintain p.f. ≥ 0.95 ;as per detailed given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no.5.3.7

1

-

-

... More
Ammonia leak detection system- as per detailed given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no.4.1.1F

1

-

-

... More
Ammonia Safety system -as per detailed given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no.4.1.1 F

1

-

-

... More
Ammonia, lubricant and propylene glycol- as per detailed given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no.4.1.1 A(bb)

1

-

-

... More
CONTROLLED ATMOSPHERE (CA) PLANT & EQUIPMENT -as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement -4A

-

-

-

... More
Central Auto analysing & monitoring equipment O2 and CO2 paramers As per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 5.1 comprising: • Complete with PLC and PC, LCD monitor & Windows 12 PRO including printer and internet connection • Software licence • Placed in the room for CA equipment • Sampling tube per room with filter (6/8 mm) • Sampling frequency per room at least once per 90 minutes • Manual and automated calibration• The CA system is equipped with the opportunity to test rooms for gas tightness • Possibility for instand extra measurement per sampling point • Control of CO2 by fresh ait inlet (aeration) during filling and emptying CA room • Adjustable action times (N2, O2 and CO2 per 0.1% deviation from set point) • Scrubber specific settings (absorbing, regenerating times) Sampling 05 CA room, the corridor(s) scrubber lung(s), purity of N2 machine technical room and outdoor condition.

1

-

-

... More
CA registration system -as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 5.1 comprising Registration of settings, values (hourly) • Output in print and digital registration • Graphs

1

-

-

... More
Automated analysers as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 5.1 comprising • O2 analyser (0-21 % range, 0.1 % reliable) • CO2 analyser (0-5 % range, 0.1 % reliable) • Both analysers equiped with display

1

-

-

... More
Calibration gases (bottles) 20 ltr including pressure regulator per bottle. 3% O2 / 0% CO2 1% O2/ 1% CO2

2

-

-

... More
Active Carbon Scrubber as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no.5.2 at level of 3 % CO2 based on control of 250 MT "Royal Delicious Apples" at level of 1 %.

1

-

-

... More
Nitrogen machine (PSA) at 99 % purity complete TO HANDLE 250 MT Storage of royal apples and Temperature protection as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 5.2

1

-

-

... More
Aeration ventilator with recoil valve capacity to handle 50 Mt chamber • Fixation flanges will be used both sides passing insulation of CA room

5

-

-

... More
Air compressor for controlling pressure valves scrubber system and valves per CA room • Including autodrain and condensing dryer • Inclusing tubing 6/8 mm to all valves • Maximal over pressure: 7.5 Bar

1

-

-

... More
Scrubber piping in PVC • Including gastight passing in CA room • Entrance in CA room behind cooler • Fixation flanges will be used both sides passing insulation of CA room

1

-

-

... More
Piping/tubing network for N2 distribution including electrical valve per CA room . Injection Valve 1/2" and piping minimal 20 mm

1

-

-

... More
Air Buffer (lungs) complete with piping flanges -

5

-

-

... More
Over- and under pressure valves (combined with buffer lung) -

5

-

-

... More
Sampling tube/valve with connected milimeter water column pressure gauge to be used for hand analysing O2 and CO2

5

-

-

... More
Testing tube with cap- 50 mm

5

-

-

... More
Portable O2 and CO2 analyser • Range 0-25 % O2 • Range 0-10% CO2

1

-

-

... More
Penetrometer for firmness test of Apples

1

-

-

... More
Refrotometer for testing SSC% of Apples

1

-

-

... More
Core temperature measurement thermometer for apples.

1

-

-

... More
Starch test equipment including Lugol (Potassium Iodide solution)

1

-

-

... More
Electrical Panel with Automatic power factor controller Panel ( APFC Panel with adequate capacitors to maintain p.f. ≥ 0.95 ; similar in design as per details given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no.5.1.2 except that only one spare feeder of 63 Amp. and Change over switch for DG Sets.

1

-

-

... More
ELECTRICALS , PIPE SUPPORTS AND PIPE & EQUIPMENT INSULATION FOR REFRIGERATION & CA PLANT EQUIPMENT - as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement -4A

-

-

-

... More
Cables , Cable tray , earthing pits etc. for complete referigeration & CA equipment as per detailed given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no. 5.3.8 & 5.3.9

1

-

-

... More
Pipe supports including for AHU , Condenser , Refrigeration and CA piping etc.as per detailed given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no.4.1.1 A(aa). The job includes bridge type supports for piping wherever necessary including civil foundfation for supports

1

-

-

... More
Pipe line insulation with in-situ PUF including for Propylene Glycol Storage Tank & Aluminum cladding. All piping (as well glycol and NH3) carrying cold coolants, are insulated with PU scales 2 x 40 mm. Above 90 mm diameter 2 x 60 mm PU scales. At the position of brackets and suspension points, the insulation is sealed and vapour-tight. Valves, pumps and other fittings may remain uninsulated. - as per detailed given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement item no.4.1.1 A ( r&s) and 4.1.1 H (i

1

-

-

... More
WOODEN BIG BINS FOR APPLES- as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement -4A

450

-

-

... More
BATTERY OPERATED FORK LIFT including spare battery set - As per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement

1

-

-

... More
HAND OPERATED PALLET MOVER - As per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement

4

-

-

... More
50 Kg platform type weighing scale -As per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement

2

-

-

... More
MISCELLANEOUS EQUIPMENT -as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement -4A

-

-

-

... More
82.5 KVA DG Set -As per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement

1

-

-

... More
Air Curtains -As per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement

2

-

-

... More
Organic Waste Convertor 50 Kg /batch

1

-

-

... More
Odour Control System (Eco- Sorb unit)

1

-

-

... More
Schedule No. 3: Design Services

-

-

-

... More
Submitting vetted design and drawings of civil works along with Geo technical investigation and topographical survey as mentioned in the employers requirement.

1

-

-

... More
submitting vetted design and drawings/ layout of mechanical works as mentioned in the employers requirement.

1

-

-

... More
Schedule No. 4: Installation Services

-

-

-

... More
Installation , testing , commissioning & handing over of Floor insulation in CA Chasmbers and Corridor ( Ante Room ) as required with PUF Insulated sheets as per employers rerquirement

320

-

-

... More
Installation , testing , commissioning & handing over PUR panels for External walls , Internal wall (partition wall), External wall of pack-house and Ceiling of CA Chamber & Corridor (Ante Room)-Employer requirement

-

-

-

... More
100 mm thick PUR Panel for external/ partion wall , ceiling and plateform in Corridor ( Ante room )

1050

-

-

... More
Gastight coating and flees as per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement and in accordance with ISO 6949 regulations

1

-

-

... More
Wall protection a s per technical specification given in Part-2- Employers' Requirement in Section-VI - and in accordance with ISO 6949 regulations applied less than 120 mm from wall. Posts of stainless steel U-100 at a foot plate 80/150/10 mm, height 500 mm, galvanised, column spacing approx. 1.500 m, with adhesive anchors fixed in the floor. Beam in stainless steel profiling at least 180 (height)/10 mm

110

-

-

... More
CA doors of size 2500 mm (W) x 3500 mm (H) with lockable control window of size 600 mm (W) x 800 mm (H) complete in all respect as per technical specification given in Part-2- Employers' Requirement in Section-VI

5

-

-

... More
Manual Horizontal Sliding Door for Corridor ( Ante Room ) of size 2500 mm (W) x 3500 mm (H) complete in all respect as per technical specification given in Part-2- Employers' Requirement in Section-VI

5

-

-

... More
Anti-collision bollards of steel to reject collision loads in the reveal area of the CA doors, consisting of an approx. 140 mm thick steel pipe, approx. 100 cm high, with foot plate doweled to the concrete floors. Material: hot-dip galvanised. ( 2 Piece / door)-a s per technical specification given in Part-2- Employers' Requirement in Section-VI - Employers' Requirement and in accordance with ISO 6949 regulations

12

-

-

... More
Installation , testing , commissioning & handing over of Refrigeration Plant & Equipment complete in all respect including electricals, pipe supports and pipe & equipment insulation as required and as per technical specification given in Part-2- Employers' Requirement in Section-VI

1

-

-

... More
Installation , testing , commissioning & handing over of Controlled Atmosphere Plant & Equipment complete in all respect including electrical panels & all electricals required for completing installation , pipe supports and pipe & equipment insulation as required andas per technical specification given in Part-2- Employers' Requirement in Section-VI

1

-

-

... More
Installation , testing , commissioning & handing over 82.5 KVA DG Set -As per technical specification given in Part-2- Employers' Requirement in Section-VI

1

-

-

... More
Air Curtains -As per technical specification given in Part-2- Employers' Requirement in Section-VI

2

-

-

... More
Installation of Organic Waste Connvertor and odour control system

1

-

-

... More
Schedule No. 5: Civil Works and ESHS

-

-

-

... More
Clearing jungle including uprooting of rank vegetation, grass,brush wood, trees and saplings of girth upto 30 cm. measured at a height of 1 metre above ground and removal of rubbish upto a distance of 20 metres outside the periphery of the area cleared as per the direction of Engineer-in-Charge. Upto 30 cm Girth:

300

-

-

... More
Felling trees of the girth (measured at a height of 1 metre above ground level) including cuttng of trunks and branches removing the roots and stacking of serviceable material and disposal of unserviceable materials as per the direction of Engineer-in-Charge. Beyond 30 cm. girth and upto and including 60 cm. girth.

4

-

-

... More
Excavation in earth work and filling in 15 cm. layers in foundation and plinths including ramming, watering and consolidating upto all leads and lifts including carriage of material within all leads, lifts and other incidentals, as per approved specifications, drawings, design and as directed by the Engineer-in-Charge.

721.37

-

-

... More
Filling of available earth upto N.G.L. (including levelling of the slopes as per instructions of Engineer Incharge) including carriage of material within all leads, lifts and other incidentals, as per approved specifications, drawings, design and as directed by the Engineer-in-Charge.

490.83

-

-

... More
Making plinth protection with flag stone flooring 40mm thick over a bed of 15cm with rammed earth and cement pointing 1:3 (1Cement :3Sand) in proper shape complete including carriage of material within all leads, lifts and other. incidentals as per specifications, approved drawing, design and as directed by the Engineer-in-Charge.

33.03

-

-

... More
Providing and laying cement concrete 1:4:8 (1 cement:4 sand: 8graded stone aggregate 40mm nominal size) mechanically mixed and curing complete excluding cost of form work in foundation and plinth within all leads, lifts and other incidentals, as per approved specifications, drawings, design and as directed by the Engineer in Charge.

110.1

-

-

... More
Preparation of sub grade by dressing to combor (Earth work for the cutting involved for subgrade to be paid for separately depending upon the classification of soil completed as per HP.PWD specifications.

376.36

-

-

... More
Stone filling in plinth dry hand packed with hard stone of approved quality under floor including watering, ramming, consolidating and dressing complete as per specifications, approved drawings and design as per entire satisfactions and direction of Engineer-in-Charge including carriage of material within all leads, lifts and other incidentals.

102.68

-

-

... More
Construction of granular subbase by providing well graded material, spreading in uniform layers with Tractor mount grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Clause 401 For Grading I Material complete within all leads, lifts and other incidentals, as per approved specifications, drawings, design and as directed by the Engineer-in-Charge.

51.34

-

-

... More
Providing and laying cement concrete flooring (40 mm thick) with 1:2:4 (1 cement :2 sand :4 stone aggregate 20 mm nominal size) mechanically mixed and vibrated including curing finishing with a floating coat of neat cement complete within all leads, lifts and other incidentals, as per approved specifications, drawings, design and as directed by the Engineer-in-Charge.

48

-

-

... More
Providing,Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment with Chlorpyriphos/Lindane/or its equivalent E.C. 20% with 1% concentration for soil under existing floors using chemical emulsion@ one litre per hole, 300 mm apart including drilling 12 mm dia Meter holes and plugging with cement mortar 1 :2 (1 Cement: 2 Coarse sand) to match the existing floor all complete as per specification.

376.36

-

-

... More
Providing and laying cement concrete tremix flooring, using truss screed beam (7 mtr - 10 mtr span) 150mm thick with cement concrete mix M-25 (RMC without flyash and slump of concrete should be 120 mm at site) and sprinkled with floor hardner of BASF Master Top 410 @ 3.0kg per sq.m. over vaccum dried concrete,including laying of steel as per design with 10 mm steel TMT shear dowel and PVC pipe sleeve cover @600mm c/c running in all direction in costruction joint and dosage of A.R glass fibre(Glassman) @ 1.00 kg/cum, complete the job in all respects.The LDPE sheet of 250 micron thick of approved quality shall be used at the base of trimix flooring. Process shall consist of laying out of panels, placing side form channels to true and proper level on cement mortar bed, poker vibrating the concrete followed by at least two passes of screed vibrator, followed by one pass of leveling beam, all using 2 to 3 mm flat on sides to allow for shrinkage on dewatering the consolidated slab, floating the vacuumed slab with one pass of skim floater, finishing with at least two passes of trowel using skim floater to give desired finish.

342.25

-

-

... More
Providing and laying cement concrete work of grade M-25 (M-Twenty Five) design mix to obtain the minimum compressive strength of 25N/mm2 (Twenty Five Newton Per square millimeter) with cement contents not less than 320kg per cubic millimeter, mechanically mixed and vibrated including curing complete, within all leads, lifts and other incidentals, as per approved specifications, drawings, design and as directed by the Engineer-in-Charge. excluding the cost of form work and reinforcement for reinforced concrete work in Foundation and plinth, Foundation footings bases of columns and the like and mass concrete. Column, pillars, posts and struts, Lintels, beams girders bressumers and cantilevers, Stair case etc.

124.4

-

-

... More
Providing and laying Tor steel reinforcement of TATA/Sail/Tisco for reinforced cement concrete work including bending, binding, cutting, straightening and placing in position complete including cost of binding wires complete as per specifications, approved drawing, design, as per entire satsfaction of the Engineer-in-charge including carriage of material within all leads, lifts and other incidentals.

301.86

-

-

... More
Providing and laying Damp Proof Course 38mm (Thirty eight millimetres) thick with cement concrete 1:2:4 (1Cement :2Sand : 4Graded crushed stone aggregate of 12.5mm nominal size)and curing complete, as required at site including carriage of materail within all leads, lifts and other incidentals, as per approved specifications, drawings, design and as directed by the Engineer-in-Charge.

6.95

-

-

... More
Applying a coat of hot bitumen mexphalt 80/100 or equivalent using 1.70 Kgs. (one decial seven zero kilogram) per square metre on damp Proof Course after cleaning the surface with a piece of cloth lightly soaked in kerosene oil, including carriage of materail within all leads, lifts and other incidentals, as per approved specifications, drawings, design and as directed by the Engineer-in-Charge.

6.95

-

-

... More
Second class brick masonry using common burnt clay builing brick in superstructure above plinth level in cement mortar 1:6 (1Cement : 6Sand) and curing complete including carriage of material within all leads, lifts of materials and other incidentals, as per approved specifications, drawings, design and as directed by the Engineer-in-Charge.

15.3

-

-

... More
Second class brick half masonry using common burnt clay builing brick in superstructurel in cement mortar 1:4 (1Cement : 4Sand) and curing complete including carriage of material within all leads, lifts of materials and other incidentals, as per approved specifications, drawings, design and as directed by the Engineer-in-Charge.

23.15

-

-

... More
15mm cement plaster in single coat on fair side of brick/concrete/stone walls forinterior plastering upto floor two level including arrises,internal rounded angles,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth with cement mortar 1:4 (1Cement :4Sand) upto floor two level including carriage of material within all leads, lifts of materials and other incidentals, as per approved specifications, drawings, design and as directed by the Engineer-in-Charge.

461.92

-

-

... More
20mm Cement plaster in single coat on rough side of brick/stone masonry for exterior plastering upto floor two level including arrises,internal rounded angles,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth with cement mortar 1:4 (1Cement :4Sand) upto floor two level including carriage of material within all leads, lifts of materials and other incidentals, as per approved specifications, drawings, design and as directed by the Engineer-in-Charge.

66.54

-

-

... More
6mm Cement plaster to ceiling in cement mortar 1:3 (1Cement :3Sand) including carriage of material within all leads, lifts of materials and other incidentals, as per approved specifications, drawings, design and as directed by the Engineer-in-Charge.

65.24

-

-

... More
Providing and fixing anodised aluminium work for door, window, ventilators and partitions with extruded built up standard tubular and other sections of approved make conforming to IS 733 and IS 1285 anodised transparent or dyed to required shade according to IS 1868. (Minimum anodic coating of grade AC 15) fixed with rawlplugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rustfree, straight, mitred and jointed mechanically where ever required including cleast angle, aluminium, snap beading for glazinge/panelling C.P. brass/stainless steel screws. All complete as per architectural drawings and the directions of Engineer-In-Charge.

-

-

-

... More
For doors windows and ventilatiors and glazed partitions frames.

117.71

-

-

... More
For shutters of doors windows & ventilators including providing and fixing hinges/pivots and making provisions for fixing of fittings where ever required including the cost of PVC/neoprene gaskets as required (fittings and glazing/panelling shall be paid for separately)

35.05

-

-

... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board confokrming to IS: 12823 Grade I Type II, in panelling fixed in aluminium doors, windows shutters and partitions frames wirth C.P. brass/ stainless steel screws etc. complete as per archititectural ddrawings and direction of Enginner-in-Charge.

-

-

-

... More
Prelaminate particle board with decorative lamination on one side and balancing lamination on other side.

75.6

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partition etc with PVC/neoprens gasket etc. complete as per the architectural drawings and the directions of Engineer-In_charge

-

-

-

... More
Glazing with glass panes of 5.50mm thickness (weight not less than 13.75 kg/ sqm.

51.36

-

-

... More
Providing and fixing 100mm brass locks (best make of approved qulaity) for aluminium doors including necessary cutting and making good etc. complete.

5

-

-

... More
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete.

-

-

-

... More
200*10mm

23

-

-

... More
150*10mm

4

-

-

... More
Providing and fixing aluminium handles anodized transparent or dyed to required colour & shade with necessary screws etc. complete as per the direction of Enginner-in-Charge. (125mm)

24

-

-

... More
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete.

-

-

-

... More
Twin rubber stopper

7

-

-

... More
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer(having brand logo with ISI, IS:3564, embossed on the body, door weight upto 35kg and door with upto 700mm) with necessary screws etc. complete.

5

-

-

... More
Providing and fixing 75mm dia stainless Hand Rail and Balusters with 04 numbers of tublar sectionas in 304 Exterior grade stainless steel work in staircase railing of ISI approved quality of Tata/Jindal or equivalent as per approved specifications, drawings, design and as directed by the Engineer in Charge.

12

-

-

... More
Providing and laying mirror polished kota stone slab 25mm (Twenty five millimetres) thick in risers of steps, skirting, dado and pillar laid on 12 mm (Twelve millimetres) (Average) thickness cement mortar 1:3 (One cement : Three sand) and jointed with Grey cement slurry mixed with pigment to match the shade of the slabs including rubbing and polishing and moulding complete including carriage of material within all leads, lifts and other incidentals, as per specifications, approved drawing, design and as directed by the Engineer-in-charge.

31.95

-

-

... More
Applying priming coat over new steel and other metal surface with readyt mixed priming paint brushing red lead, Red-Oxide/Zinc Oxide chrome after and including preparing the surface throughly cleaning oil grease dirt and other foreign matter and scoured with wire brushes fine steel wool scrappers, sand prepers complete including carriage of material within all leads, lifts and other incidentals, as per specifications, approved drawing, design and as directed by the Engineer-in-charge.

19.6

-

-

... More
Painting two or more coats (excluding priming coat) with Nerolac/Asian paint on new steel and other metal surfaces with enamel paint brushing to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matters including carriage of material within all leads, lifts and other incidentals as per specifications, approved drawing, design and as directed by the Engineer-in-charge.

19.6

-

-

... More
Applying Birla J.K. white wall care putty over plaster surface after thoroughly brushing the surface free from mortar dropings, dust, loose material and other foreign matters, sand papered smooth to give final matt finish to the surface complete including entire carriage of material within all leads, lifts and other incidentals as per specifications, approved drawing, design and as directed by the Engineer-in-charge.

593.69

-

-

... More
Finishing wall with weather proof exterior grade emulsion of approved design (Apexultima) or its equarlied on undecorated wall surfaces (two coats) to give an even shade and final finish after throughly cleaning the surface to remove all dirt, dust and other foreign matter etc including sand paper smooth complete.

66.54

-

-

... More
Applying one coat of AcrylicWashable emulsion Spectrum quartz king or equivalent finish for interior painting with brushes plain smooth finish composed of acrylic polymere in emulsion inorganic/special pigment siliceous aggregate anti fungicides anti-rusting & foaming in two coat i/c necessary putty to give smooth even surface, sand papered smooth complete.

461.92

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.

19.6

-

-

... More
Providing and fixing ball bearing for rolling shutters.

4

-

-

... More
Providing form work with steel plates 3.15mm (Three decimal one five millimeres) thick welded with angle iron frame 30x30x5 mm (Thirty into Thirty into Five millimetres) so as to give a fair finish including centring shuttering strutting and proping etc. with wooden battens and ballies,height of proping and centring below supporing floor to ceiling not exceeding 4 mtrs.and removal of the same for in situ-reinforced concrete and plain concrete work in :

-

-

-

... More
Foundation , footing basis of columns etc. and mass concrete including carriage of material within all leads, lifts and other incidentals, as per specifications, approved drawing, design and as directed by the Engineer-in-charge.

92.58

-

-

... More
Columns, pillars, posts and struts including carriage of material within all leads, lifts and other incidentals, as per specifications, approved drawing, design and as directed by the Engineer-in-charge.

295.8

-

-

... More
Beams, cantilever, girders and lintals.Sides and soffits of beams, beam haunching,cantilevers,bressumers and lintals 1 mtrs. In depth in all height including carriage of material within all leads, lifts and other incidentals, as per specifications, approved drawing, design and as directed by the Engineer-in-charge.

945.36

-

-

... More
Stair case with sloping or stepped soffits excluding landing including carriage of material within all leads, lifts and other incidentals, as per specifications, approved drawing, design and as directed by the Engineer-in-charge.

11.55

-

-

... More
Flat surface such as soffits of the suspended floors, roofs, landings and the like floor etc. upto thickness of 200 mm thickness including carriage of material within all leads, lifts and other incidentals, as per specifications, approved drawing, design and as directed by the Engineer-in-charge.

167.23

-

-

... More
Vertical surfaces such as walls(any thickness) partitions and the like including attached pillastersbuttresses,plinth and string courses including carriage of material within all leads, lifts and other incidentals, as per specifications, approved drawing, design and as directed by the Engineer-in-charge.

72.92

-

-

... More
Providing and laying water proofing treatment in sunken portion of WCs,bathroom etc by applying cement slurry mixed with water proofing cement compound consisting of applying (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @0.253 kg/sqm.This layer is allowed to air cure for 4 hours. (b) Second layer of slurry of cement@ 0.242 kg/sqm mixed with water proofing cement compound@ 0.126kg/sqm.This layer is allowed to air cure for 4 hours with water proofing curing for 48 hours.

60.73

-

-

... More
Providing and laying Double charged vetrified tiles of 10mm (Ten millimeter) antiskid of Orient/ Somany/Rak/Nitco as per approved shade in flooring of size upto 600x600mm in flooring laid on a bed of 12mm (Twelve milimetres) thick cement mortar 1:3 (One cement : three sand) finished with flush pointing in white cement upto all floor levels complete including carriage of material within all leads, lifts and other incidentals, as per approved specifications, drawing, design and as directed by the Engineer-in-charge.

34.88

-

-

... More
Providing and fixing 300x600mm (Three hundred into six hundered millimetres) glazed tiles of 6mm (Six millimetres) Kajaria/NITCO/RAK/Asian or equivalent in skirting and dado upto all heights with 12mm (Twelve milimetres) thick cement mortar 1:3(One cement :Three sand) jointing with cement slurry complete including carriage of material within all leads, lifts and other. incidentals as per specifications, approved drawing, design and as directed by the Engineer-in-Charge.

92.4

-

-

... More
Design, fabrication, supplying and erection/ installation of Pre- Engineered Steel Structure Building ( PEB) for CA STORE of size mentioned in drawings complete with detailed scope of work specified in technical specificcations and drawings including carriage of material within all leads, lifts and other incidentals, as per approved specifications, drawing, design and as directed by the Engineer-in-charge.

1

-

-

... More
Supplying and fixing MS Gate at Entrance using Steel angles, Flats etc., as per approved design including providing RCC Pillars with necessary foundation complete including carriage of material within all leads, lifts and other incidentals, as per approved specifications, drawing, design and as directed by the Engineer-in-charge.

700

-

-

... More
Providing and fixing 3.0 mtr high G.I chain link fabric fencing with 'Y' shaped angle iron posts placed at 3 mtrs c/c and strutted at every 15 th post/last but one post/corner post of overall height 3.8 with Y arms of 450 mm length and effective height 300 mm, in mesh size 25x25 mm made of G.I wire of dia 3 mm including strenthening with 2 mm dia wire or nuts, bolts and washers as required complete including providing 6 rows ( 3 rows on each arm) of GI barbed wire 9.38 kg per 100m above 2mtr chainlink fabric complete with supply of all materials, labour, T&P including angle posts as per the instructions of Engineer I/C With G.I. Chain link fabric (Payment to be made for per metre of complete fencing)

180

-

-

... More
Supplying and fixing at site 65x65x6 mm Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. Etc. complete including a priming coat and two coats of enamel paint, earth excavation, providing PCC 1:3:6 (450X450X600 mm), shuttering if required, curing, surplus earth disposal, etc complete in all respects.

1192.5

-

-

... More
Steel work welded in built up sections,trusses and framed work in any section angle/channel or tubler including cutting ,hoisting , fixing in position complete and applying a priming coat of red lead paint in trusses and trussed purlins in building and simillar works complete as per the specifications and as directed by the Engineer-in-Charge, including entire carriage of material within all leads, lifts and other incidentals.

11

-

-

... More
Providing and fixing 0.60mm (Zero decimal Six zero millimetre) thick prepainted steel sheet of TATA Durashine/Sail/Jinda ISI marked-2-1201 in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 (Twenty) microns over 5 (Five) microns primer coating to back coat of polyster of 10 (Ten) microns over 5 (Five) microns primer coating including fixing with prepainted iron J or L hooks, bolts and nuts 6mm (Six millimetres) diametre with prepainted limpet and rubber washers complete including carriage of material wihin all leads, lifts and other incidentals as per specifications, approved drawings, design as directed the the Engineer-in-charge.

60

-

-

... More
Providing and fixing ridges or hips laying proper shape 60cm (Sixty centimetres) overall with 0.60mm (Zero decimal Six Zero millimetres) thick prepainted steel sheets in roofing with hot dipped metalic zinc coated sheets with top coat of regular modified polyster organic coating of 20 (Twenty) microns over 5 (Five) microns primer coating + back coat of polyster of 5 (Five) microns over 5 (Five) microns primer coating including fixing with prepainted iron J or L hooks, bolts & nuts 6mm (Six millimetres) dia & prepainted G.I. limpet and bitumen washers complete including carriage of material wihin all leads, lifts and other incidentals as per specifications, approved drawings, design as directed the the Engineer-in-charge.

20

-

-

... More
Providing and fixing 15 cm. (Fifteen centimetres) wide 45 cm. (Fourty Five centimetres) overall semicircular 0.63 mm (Zero decimal Six Three) thick of TATA plain G.I. sheet gutter with iron brackets 40x3mm size bolts and nuts and washers etc. and making necessary connections with rain water pipe compete including carriage of material wihin all leads, lifts and other incidentals as per specifications, approved drawings, design as directed the the Engineer-in-charge.

20

-

-

... More
Providing and fixing 150mm (One hundred fifty millmetres) dia pipes on wall face/column face P.V.C (D-Plast) rain water pipes of 6 Kgs ( Six kilogram) ISI make of Finolex/Relpipe/Victous of working pressure not less than 4.5 kg/sqm (Four point five kilograms per sqaure millimetres) high density pipe (HDP) including filling the joints with approved adhesive complete as per specifications and as directed by the Engineer-In-charge, including entire carriage of material within all leads, lifts and other incidentals.

15

-

-

... More
Providing and fixing on wall face/column face P.V.C. (D-plast) acessories for rain water pipes 6 kgs/sqm (Six kilograms per square millimetres) as per IS mark of Phenolex Relpipe (Reliance) victus working pressure class-B un plastisized PVC D-Plast high denesity pipe confiming to ISI Code 4545:2004 for rain water pipe fixed with approved adhesive including filling the joints complete including carriage of material within all leads, lifts and other. incidentals and further as per specifications, approved drawing, design and as directed by the Engineer-in-charge.

-

-

-

... More
150mm (One Hundred Fifty millimetre) diametres PVC Plain bend

10

-

-

... More
150mm (One Hundred Fifty millimetre) diametres PVC Plain shoe

5

-

-

... More
Providing and fixing M.S. holder bat clamps of approved design to H.D.P. rain water pipe embedded in and including cement concrete blocks 10x10x20cm of 1:2:4(One cement: Two sand: Four graded crushed stone aggregate 20mm (Twenty milimetres) nominal size and cost of cutting holes and making good the walls etcetera; complete as per specifications and as directed by the Engineer-In-charge, including entire carriage of material within all leads, lifts and other incidentals.

15

-

-

... More
Providing and fixing 12 mm thk. Gypsum board false ceiling with 24 gauge G. I. frame at 2’ 0” c/c bothways, suspended to the main ceiling with brass screws, suspenders, including proper boxing / cutouts with extra framework for fixing lighting pelmet, fixtures, A. C. grills, spotlights, Gypsum board joint should be covered with approved tape etc. Complete including primer work and painting in 3 coats of Acrylic Emulsion paint or equivalent as directed by Engineer In-charge.

52.5

-

-

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

-

-

-

... More
For horizontal surface one coat @1.10 kg per sqm.

21.78

-

-

... More
For vertical surface two coats @ 0.70 kg per sqm

19.8

-

-

... More
Rectangular shape 500x500 mm precast R.C.C. manhole cover with frame - M.D. - 10

1

-

-

... More
Steel work welded in built up sections,trusses and framed work,including cutting ,hoisting ,fixing in position and applying a priming coat of red lead paint in gratings framed guard bars, ladders, railing, bracketes and simillar works complete as per the specifications and as directed by the Engineer-in-Charge, including entire carriage of material within all leads, lifts and other incidentals.

20

-

-

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

-

-

-

... More
For horizontal surface one coat @1.10 kg per sqm.

16.82

-

-

... More
For vertical surface two coats @ 0.70 kg per sqm

17.98

-

-

... More
Rectangular shape 500x500 mm precast R.C.C. manhole cover with frame - M.D. - 10

1

-

-

... More
Steel work welded in built up sections,trusses and framed work,including cutting ,hoisting ,fixing in position and applying a priming coat of red lead paint in gratings framed guard bars, ladders, railing, bracketes and simillar works complete as per the specifications and as directed by the Engineer-in-Charge, including entire carriage of material within all leads, lifts and other incidentals.

20

-

-

... More
Earth work in excavation of foundation for structure i.e. retaining wall as per drawing and technical specification including setting out,construction of shoring and bracing removal of stums and other deletarious materials, dressing of sides and bottom, backfilling of the excavated earth to the extent required upto all lead and lifts as per the direction of Engineer-in-Charge.

293.01

-

-

... More
Providing and Laying cement concrete 1:4:8 (1Cement :4Sand :8graded aggregate of specified size) mechanically mixed in structure of retaining wall complete as per drawings and HP.PWD technical specifications with complete curing including the cost of formwork, carriage of material within all leads, lifts and other incidentals, as per specifications, approved drawing, design and as directed by the Engineer-in-charge.

95.82

-

-

... More
Providing weepholes in brick masonry/stone masonry/plain reinforced conrete abutment,wing wall, return wall with 100 mm dia. PVC pipe extending through the full width of the structures with slope of 1(v) : 20 (H) towards drawing face complete as per drawing and technical specification clauses 614,709,1204.3.7 including carriage of material within all leads, lifts and other incidentals, as per specifications, approved drawing, design and as directed by the Engineer-in-charge.

220

-

-

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 including carriage of material within all leads, lifts and other incidentals, as per specifications, approved drawing, design and as directed by the Engineer-in-charge.

132

-

-

... More
Back filling behind retaining wall/breast wall complete upto NGL level with grannular material including carriage of material within all leads, lifts and other incidentals, as per specifications, approved drawing, design and as directed by the Engineer-in-charge

247.5

-

-

... More
Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth upto all distances as per Technical Specification Clause 1603.1 including all leads, lifts and other incidentals, as per approved specifications, drawings, design and as directed by the Engineer in Charge.

54.47

-

-

... More
Providing and laying heavy duty precast cement concrete 80mm (Eighty millimetres) thick precast paver blocks ISI marked of NTC or equivalent IS No 15658 with vibro compacted upto M-50 (M-Fifteen) grade including border or kerb block grey or coloured laid over sub-base of concrete with 25mm (Twenty five millimetres) thick average thickness of cement mortar 1:4 (One cement : Four sand) and jointed with neat cement slurry mixed with pigment to match the shade of blocks including curing rubbing & polishing complete including carriage of material within all leads, lifts and other. incidentals as per specifications, approved drawing, design and as directed by the Engineer-in-Charge.

292.23

-

-

... More
Sign Boards

-

-

-

... More
PCC M-15 Providing and laying cement concrete 1:2:4 (1 cement:2 Sand:4 graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work

0.27

-

-

... More
Steel work welded in built up sections,trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of red lead paint. In beams joists channels, angles, tee, flats with connection plates or angle cleats as in main and cross beems, hip and jack rafters, purlins connected to common rafters and the like

0.42

-

-

... More
Galvanized structural steel plate 200mm wide 6 mm thick 24m long

61.6

-

-

... More
Painting Lettering with paints of approved brand and manufacture with readymixed paint (other than white) letters/figures of 15 cm height

100

-

-

... More
Painting two coats (excluding priming cost on new steel and other metal surfaces eith enamel paint brushin to give an even shade including cleaning the surface of all dirt, dust and other foreign matters: Enamel white paint

1.31

-

-

... More
HAND APPLIANCES

-

-

-

... More
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body,squeeze lever discharge valve fitted with internal discharge tube, 30cms long ISI marked high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5kg. I.S.I. Marked.

2

-

-

... More
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body,squeeze lever discharge valve fitted with internal discharge tube, 30cms long ISI marked high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 9.0 Kg ISI Marked.

2

-

-

... More
Providing and fixing carbon-di-oxide fire extingushers trolley mounted with all accessories internal discharge tube, high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.: Capacity 22.5 kg

1

-

-

... More
Providing and fixing carbon-di-oxide fire extingushers trolley mounted with all accessories internal discharge tube, high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.: Capacity 22.5 kg

1

-

-

... More
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter "FIRE" in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer with stand.

2

-

-

... More
Safety siren/ alarm (at admin building)

1

-

-

... More
Providing and installing Pre fabricated mobile toilet with 02 seater capacity along with proper waste disposal system including normal specifications

1

-

-

... More
Rental temporary accomodation of 30 to 40 Nos. of migrant workers including Rooms, Creche, Dispensary and Toilets & kitchen etc complete with normal Specification and average life of building is within 30 to 35 years (rental for 18 months). Minimum area 180 sq mtr

18

-

-

... More
INTERNAL/ EXTERNAL LIGHTING WORKS

-

-

-

... More
PVC INSULATED HEAT RESISTANT FLAME RETARDANT AND LOW SMOKE (HRFRLS) COPPER CONDUCTOR WIRING IN PVC CONDUIT Wiring for light point / fan point / exhaust fan / call bell point with 1.5sqmm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required: Group C

60

-

-

... More
Wiring for twin control light point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sqmm FRLSPVC insulated copper conductor single core cable etc as required.

10

-

-

... More
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1No. 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.

150

-

-

... More
Wiring for power plug with 2x4 Sq. mm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC Conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.

150

-

-

... More
Wiring for power plug with 4x4 Sq. mm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC Conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.

100

-

-

... More
Wiring for circuit/sub-main with following size pve insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface / reccessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same Size for earthing as

-

-

-

... More
2x1.5 Sq mm (For Light CKTs / Secondary Light Point)

500

-

-

... More
2x2.5 Sq mm (For Chamber Light)

350

-

-

... More
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke sirgle core (flexible) copper conductor cable in surface / recessed PVC conduit along with 2 No.10 Sq.mm. (4x10 + 2x10) HRFRLS/PVC insulated single core copper

80

-

-

... More
Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke sirgle core (flexible) copper conductor cable in surface / recessed PVC conduit along with 2 No.16 Sq.mm. (4x16 + 2x16) HRFRLS/PVC insulated single core copper

80

-

-

... More
SUPPLYING AND FIXING PVC CONDUITS: Supplying and fixing of 50 mm dia PVC conduit along with the accessories in surface / recess including cutting the wall and main good the same in case of recessed conduit as required :

180

-

-

... More
SUPPLYING AND FIXING METAL BOXES: S/F Metal boxes following sizes (nominal size) on surface or recessed suitable for fixing phenolic laminated sheet cover in front including painting etc. as as required:

-

-

-

... More
200mm x 150mm x 75mm deep

6

-

-

... More
250mm x 300mm x 100mm deep

4

-

-

... More
ERECTION OR FITINGS AND ACCESSORIES: Supplying and fixing GI Modular box of (100mmx75mmx50mm) size with modular plate and cover in recess including providing and fixing pin 5/6 amps modular socket, outlet and 5/6 amps modular switch connections etc. as required.

25

-

-

... More
Supplying and fixing G.I. Modular box of (100mmx75mmx50mm) size with modular plate and cover In recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch connections etc. as required.

8

-

-

... More
Supplying and fixing ceiling rose on the existing junction box / wooden block including connections etc. as required.

1

-

-

... More
Supplying and fixing bakelite batten/angle holder including connections etc as required:

1

-

-

... More
Supplying and fixing GI Modular box of (75mmx75mmx50mm) size with modular plate and cover in recess including providing and fixing pin 5/6 amps modular switch, connections etc. as required.

30

-

-

... More
Supplying and fixing GI Modular box of (100mmx75mmx50mm) size with modular plate and cover in recess including providing and fixing pin 5/6 amps modular 2way switch, connections etc. as required.

4

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
25 mm

180

-

-

... More
32 mm

40

-

-

... More
40 mm

40

-

-

... More
METAL BOARDS FOR SWITCH GEAR MOUNTINGS: Supplying and erection of following depth, sheet metal cubical pedestal of suitable' dimensions 'with plus-minus 5 cm variation, made from 1.6 mm thick. MS sheet duly fabricated in a segregated manner for housing of switch fuse units, by welding each compartment on five sides & front side hinged, complete with locking arrangement with sufficient. No vertical and horizontal intermediate switchgear housing compartments. The cubical pedestal shall have cable entry box at one or two sides with epoxy powder coated approved paint and bonding to the existing earth etc. The same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15cm high from ground level and 45cm thick. The cubical pedestal shall be 15cm from the top of cement concerete platform: 300 mm deep (nominal)

2.2

-

-

... More
1300 SUPPLYING AND FIXING OF BUS BARS IN THE EXISTING CHAMBER / CUBICAL Copper Busbar - Supplying and fixing copper strip bus-bars suitable for 200A 415V capacity 4No. Each of cross-sectional area (25.4mm x 4.75mm), in each existing enclosure or cubical with all accessories including

2.2

-

-

... More
MOULDED CASE CIRCUIT BREAKERS AND AIR CIRCUIT BREAKERS: Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubical panel making connections, etc. as required

-

-

-

... More
63A / 40A - 16KA

6

-

-

... More
160A - 16KA

1

-

-

... More
MINIATURE CIRCUIT BREAKES / RESIDUAL CURRENT CIRCUIT BREAKERS: Supplying and erection of 6 amps to 32 amps rating, 10KA breaking capacity, 240V, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections

-

-

-

... More
Single Pole Cat-A

30

-

-

... More
Double Pole Cat-A (63A)

6

-

-

... More
Triple Pole Cat-A (32A)

1

-

-

... More
Supplying and fixing 20 amps, 240 volts, SPN moulded type, socket outlet, with 2 pole and earth, enclosed plug top along with 20 amps "C" curve, SP, MCB, in moulded enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

-

-

... More
Supplying and erection of 40/50/63 amps rating, 10KA breaking capacity, 240V, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections: Triple Pole & Neutral Cat-A (63A)

8

-

-

... More
Supply and fixing 30A 415V TPN industrial socket outlet, 4-pole and earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 30A TPN-MCB on surface or in reecss, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required.

3

-

-

... More
MCB DISTRIBUTION BOARDS: Supplying and fixing of following way single pole and neutral sheet steel MCB dislribution board 240V on surface / recess complete with tinned copper bus. bar. wire-set, neutral link. earth bar, din-bar, detachable gland plate, cable. identification labels interconnections phosphatized and powder painted including earthing as required - Double Door-6 Way

1

-

-

... More
Supplying and fixing of following way triple pole and neutral. sheet steel MCB dislribution board. 415V on surface / recess. with provision for 4 pole MCB/lsolator/RCCG/RCBO as incomer and sr MCBs as outgoing, complete with tinned copper bus. bar. wire-set, neutral link. earth bar, din-bar, detachable gland plate, cable. identification labels interconnections phosphatized and powder - Double Door-4 Way (8+12) horizontal

3

-

-

... More
EARTHING AND LOOP EARTHING

-

-

-

... More
GI Electrode Earthing with 80 mm dia and 3 meter length, The electrode should be hot-dip galvanized with 120-150 micron. The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 50 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-friendly and having RoHs certification .GI Electrode Earthing should be maintenance free and dose not required regular manual addition of water. GI Electrode Shall be tested from CPRI.The earting pit should be cover with FRP cover, of 300 x 300 mm.

10

-

-

... More
Supplying and fixing 25mm x 5mm copper strip on surface or in recess for earthing connection etc. as required

30

-

-

... More
Supplying and fixing 25mm x 5mm GI strip on surface or in recess for earthing connection etc. as required

180

-

-

... More
LIGHTENING CONDUCTOR: Providing and fixing of Lightning conductor finial, made of 25mm dia 300mm long GI tube, having single prong at top, with 85mm dia 6mm thick GI base plate including hole etc. complete as required.

6

-

-

... More
Riveting, sweating and soldering of copper / GI tape with another copper / GI tape base of the finial or any other metallic object as required.

10

-

-

... More
Supply and fixing GI tap 20mmx3mm thick on parapet or surface of wall for lightening conductor as required (for vertical run)

60

-

-

... More
Supply and fixing GI tap 20mmx3mm thick on parapet or surface of wall for lightening conductor as required (for horizontal run)

180

-

-

... More
Supplying and laying of GI tape 32mmx6mm thick from earth electrode to directly in ground as required.

25

-

-

... More
UNCLASSIFIED ITEMS: Providing and fixinng MV danger notice plate of 200mm x 150mm made of mild steel at least 2mm thick and vitreous enameled white on both sides and with inscription in signal red color on front side as required

4

-

-

... More
ALUMINIUM CONDUCTOR PVC INSULATED ELECTRIC ARMOURED CABLES: Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured / XLPE power cable, working voltage 1100V grade on surface and ground of the required size.

-

-

-

... More
Armoured Cable 6sqmm (twin core)

21

-

-

... More
Armoured Cable 70sqmm (3.5 core)

20

-

-

... More
Cu cable Armoured Cable 35 sqmm (3.5 core)

100

-

-

... More
PROVIDING AND INSTALLATION OF CEILING / EXHAUST FANS: Providing and installation of exhaust fan of following sizes in the existing opening, including' making the hole to suit the size of the above fan. making good the damages. connections. Testing and commisslonina etc as reauired: Exhaust fan, heavy duty 380mm sweep including suitable Louver

4

-

-

... More
SUPPLYING AND FIXING OF WALL BRACKETS / CEILING FITTINGS: Supplying and fixing of bulk head fitting of all sizes and shapes, containing one No. thread type CFL lamp holder(s), complete with all accessories but excluding CFL lamp including making connections. testing etc as required - Bulk Head Fitting, CFL type (Category - A)

4

-

-

... More
2800 Supply and erection of Poles: Supplying and erection of street light bracket made of GI pipe 'A' class of suitable length and dia, the pipe bended to give an angle of 100 to 110 degree fitted with bolt and nuts at the top of existing pole or wall including painting the pipe with two coats of approved paint over prming coat complete in all respects as required: 40mm dia GI pipe heavy class

4

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of up to 150 sqmm size in the existing RCC/ HUME/ METAL pipe as required. (Laying of MV Cables)

120

-

-

... More
CABLE TRAY AND RACE WAY: Supply, laying & fixing 14 SWG single compartment GI race way of following sizes along-with necessary cable support system as directed including fixing accessories like dash fasteners cable ties and junction box etc. complete in all respects including earthing of trunking with 4sqmm. PVC insulated wires including cutting chasing of floor and making of good (cutting of floor by machine).GI Race ways shall be minimum 20mm below floor finish as required as per approved drawings and directions of Project Manager

-

-

-

... More
40x 300 x 40mm deep

50

-

-

... More
50 x 225 x 50mm deep.

20

-

-

... More
Supplying & installing following size of perforated pre-painted M.S cable trays with perforation not more than 17.5%, in convinient sections,joined with connectors, suspended from the ceiling with M.S suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
600 mm width x 62.5 mm depth x 2.0 mm thickness

80

-

-

... More
450 mm width x 62.5 mm depth x 2.0 mm thickness

20

-

-

... More
DISTRIBUTION BOARD & 3 PHASE METER & SUB MAIN DISTRIBUTION BOARD (SMDB): Supplying and fixing 12 Way TPN DB Double Door (Vertical) surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board double door of sheet steel, dust protected, duly powder painted, inclusive of 80 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s, with provision of 40A / 63A TP 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars ( with 6 MCB’s/ MCCB) as required.

2

-

-

... More
S/I/T/C sheet steel inclosure for 32-63Amp TPN/DP/SPN MCB complete with all accessrories as required.

2

-

-

... More
MULTIFUNCTION METER: S/I/T/C 3 Phase Multifunction Meter, L&T, 4410 LED, Class 0.5 with RS 485 along with 3 Nos. CTs of 100/5A Class-I and 3 phase indicator lamps, internal wiring with copper flexible wire, all connections, testing, commissioning and other petty material required to complete the job including labour charges or erection in existing cubical panels with cost of cutting the panel sheet and din bars etc.

2

-

-

... More
LIGHTING FIXTURES: Supply, Carriage, erection, testing and commissioning of LED fitting. The lumen output of LED should be minimum 100 lumens per watt and should be type tested from NABL I UL accredited laboratory for LM79 & LM80 test reports and copy of same has to be submitted to the client department. The Fixture supplied with Electronic high efficiecy driver having Power factor 0.9, THD 10%. The sample of fitting shall be got tested in the presence of representative from NABL I UL accredited laboratory and the testing fee shall be borne by the contractor / supplier.

-

-

-

... More
S/E of 40W LED Liner fitting surface mounted. made of extruded aluminium heat sink body provided for efficient heat dissipation & integrated electronic driver suitable for single phase A.C. 230V, 50 HZ supply, high efficent fixtures complete in all. The job includes cost of cutting the false ceiling to fix the fitting including giving support of chain from ceiling or frame and making connection to the nearest point with copper wires.

20

-

-

... More
S/E of 40W LED Liner fitting surface mounted. made of extruded aluminium heat sink body provided for efficient heat dissipation & integrated electronic driver suitable for single phase A.C. 230V, 50 HZ supply, high efficent fixtures IP65 complete in all. The job includes cost of cutting the false ceiling to fix the fitting including giving support of chain from ceiling or frame and making connection to the nearest point with copper wires.

40

-

-

... More
S/E of Surface Mounted LED 40 W Fitting Panel of size 4' foot long complete with driver. The fitting is to be fixed on ceiling with anchor fasteners.

100

-

-

... More
12W LED round fitting recess mounted. The job includes cost of cutting the false ceiling to fix the fitting including making connection to the nearest point with copper wires.

15

-

-

... More
S/I/T/C of LED street light light fitting of 70W / 72W rating with minimum 110 lumens per watt. The fitting is to be fixed on existing bracket mounted on Pole. The job includes cost of fitting, wiring connection etc. required to complete the job.

3

-

-

... More
Supply ,Fixing, testing and commissioning of internal road light poles including the cost of providing top 70mm and bottom 130mm dia 3 mm thick 200x200x12mm MS base plate welded to the base of the pipe , Arm Length 1000mm and including digging and including the cost of masonry base pedestal built with 1:3:6 concrete (1 cement, 3 coarse sand and 6 graded stone aggregate 40 mm nominal size) provided with a 200 mm x 150 mm x 100 mm deep looping cable GI box recessed in the base pedestal / surface mounted fabricated from 14 SWG GI sheets with hinged gas kitted lockable door, terminal block for incoming and outgoing PVCA cables, 10 amps SP MCB, 2 Nos. suitable length 25mm dia GI pipe for incoming and outgoing cables and including the cost of painting, wiring, in pole from terminal block up to the light fittings with 2 x 2.5 sq.mm copper conductor 1100 volt grade PVC insulated wires along with loop earthling with 1 no. 8 SWG GI wire, earth stud etc. complete as required and as below. IS2713-PART II 6 mtr Long Swaged Pole. Planting depth shall be 600 mm. Height above ground shall be 5.4 metres including MCB & M.S. box etc. as required.

3

-

-

... More
S/I/T/C of LED street light light fitting of 25W rating with minimum 110 lumens per watt. The fitting is to be fixed on existing bracket mounted on wall. The job includes cost of fitting, wiring connection etc. required to complete the job.

4

-

-

... More
S/E of Self contained with 8W fluorescent tube for non maintained emergency lighting for 3 hours duration Complete as required.

5

-

-

... More
S/E of 230/48Volts 440AH ,Battery charger with rectifier, DC Ammeter, DC Voltmeter and common DC bus for DC supply to battery.

2

-

-

... More
ADDRESSABLE FIRE DETECTION & FIRE ALARM SYSTEM WITH PA: Supply, installation, testing and commissioning of Microprocessor based intelligent analogue addressable, modular, expandable networkable, following loop (each loop consist of Minimum 99 detector & 99 devices) fire alarm control panel with minimum 6 inch LCD display, multiple access levels, event history file in non-volatile memory (EEPROM). The panel shall have a built-in integrated voice command center with suitable rating amplifier for 25 Nos. of speakers. The panel shall support programmable relay for controlling lifts, staircase pressurizations fans, lift shaft & lift lobby pressurization fans, toilets exhaust fans, ventilation fans, monitoring of fire sprinkler and fire hydrant pump controlled by powerful Boolean logic equation. The panel shall have minimum five independent hazard release circuit built-in the panel. The panel shall have 240 volts AC power supply, automatic battery charger, 24 volts, sealed lead acid maintenance free batteries sufficient for 24 hours normal working and then be capable of operating the system for 4 hours during emergency condition i /c interfacing connectivity (BAC Net/modbus gateway) in Fire Panel for integrating with building management system complete as per Technical specification of tender . The panel shall be UL/FM listed. (UL 9th Edition Approved) (The panel shall be complete with suitable power supply to operate the as per detectors and devices in case of Emergency but not less than 10 Amp.)

1

-

-

... More
Supplying, installing, testing and commissioning Automatic Floating Sensitivity type Analog addressable Accilimate Multisensor (Photo thermal) smoke cum heat detector with mounting based LED, address switch to programme the detectors complete as required.( It shall be UL/FM listed.)

40

-

-

... More
Providing, installing, testing and commissioning of Repeater Panel for Fire Alarm System with piezo sounder, LCD alpha numeric character display with accept/reset buttons for alarm address of any sensor/field device. The Repeater Panel shall only provide field device address. Analogue output is not required. The Panel shall be connected to the Fire Alarm Panel

1

-

-

... More
Supply, installation, testing and commissioning of Addressable type fault isolator for isolating shorted, dewired and loose circuits between two successive fault isolators with automatic resetting arrangement (base model)

3

-

-

... More
Supply, installation, testing and commissioning of Addressable control relay modules for AHU & stairs Pressurization Fan.Hooter and manual call point etc.

3

-

-

... More
Supply, installation, testing and commissioning of Hooter/Strobe Lights with 110 cd. The strobes shall be synchronized for better evacuation.

4

-

-

... More
Supply and laying of 2 Core, 1.5 Sq. mm twisted pair copper conductor cable, low smoke zero halogen, high performance silicon rubber insulated, overall shielded, sheathed fire survival (HPSR) armored cable on surface/ recess/ existing couduit/ existing cable tray complete in all respect as per BS 6387 CWZ, EN50200, LPCB approved for the same size.

300

-

-

... More
Supplying, installing, testing and commissioning of Analog Addressable air duct smoke detector with an efficient housing design and sampling tubes mounting based LED, Address Switch to programme the detectors, complete as required. (FOR AHU's).(It shall be UL/FM Listed)..

1

-

-

... More
Supplying, installing, testing and commissioning of Response Indicator.

1

-

-

... More
Supplying, installing, testing and commissioning Fire panel supervised 70db-84db Wall Mounted multi tap 12 Watt Speaker as specified & same make as of panel.

4

-

-

... More
Supplying, installing, testing and commissioning 2 way communication Fire Fighter's Handset

2

-

-

... More
Supplying, installing, testing and commissioning 2 way communication Fire Fighter's Telephone Jack as per specifications complete as required.

2

-

-

... More
Supplying, installing, testing and commissioning Addressable Manual Pull Station complete as required.( It shall be UL/FM listed.)

5

-

-

... More
NETWORKING AND VOICE SYSTEM: DATA PASSIVE COMPONENT

-

-

-

... More
Supply, installation, testing and commissioning of 4 pair Category 6 UTP LSZH cable in existing conduit/ surface/recess/cabletray. Consisting of 24 AWG solid copper conductors complete with flexible jacket and ripcord for easy stripability etc complete as required as per specifications.

300

-

-

... More
Supply, installation, testing and commissioning of category 6(E) flush mounted information outlets wired according to T568B standard with a faceplate.

4

-

-

... More
Supply, Installation & Testing of Cat.6 E UTP 24-port Non-Shutter Patch Panel, Un-loaded with Layer II Managed Gigabit Ethernet switch: 8 port RJ45 10/100/1000 T (POE). INCLUDING SINGLE MODE SFP with transreceiver all network accessories like patch code , connectors etc for successful operations etc complete as required .

1

-

-

... More
RJ 45 Connectors UTP with all accessories

4

-

-

... More
Supply, Installation & Testing of 1U Cable Management Panel.

1

-

-

... More
Supply, Installation & Testing of Cat6 Patch Cord UTP 2M CM, Blue for Field Side.

4

-

-

... More
Supply, Installation & Testing of Cat6 Patch Cord UTP 4ft CM, Blue for Rack Side.

4

-

-

... More
Supply, Installation & Testing of Cat6 Patch Cord UTP 7 ft , Blue for User Side.

2

-

-

... More
Wi-Fi Access Point for Guest Floor and Admin

3

-

-

... More
WAP Controller for above Aps

1

-

-

... More
12 Port Ethernet Edge Switch 10/100 for Wi-Fi

1

-

-

... More
Core Switch 10/100/1000 cum router for above Wireless Network

1

-

-

... More
CLOSED RACK 12U: Rack 19'' 12 U 600W/800D( with front VNTD Glass Lockable Doors,Back Fully perforated Door, lockable and removable side panels, with 10 pin Vertical PDU

1

-

-

... More
Castor ,Tyreman,FT brake & Back STD

1

-

-

... More
Vertical Cable Manager

2

-

-

... More
Fan HSG,90 CFM,4 FAN

1

-

-

... More
Fan 230 VAC,90 CFM

1

-

-

... More
NETWORKING AND VOICE SYSTEM:VOICE PASSIVE COMPONENT

-

-

-

... More
Supply ,Installation &Testing of Cat.5 8-port Non-Shutter Patch Panel, Un-loaded Field.

1

-

-

... More
Supply ,Installation &Testing of 1U Cable Management Panel.

1

-

-

... More
Supply ,Installation &Testing of Cat.5, 8-port Non-Shutter Patch Panel, un-loaded Resource.

1

-

-

... More
Supply ,Installation &Testing of Cat5 Patch Cord UTP 7 ft , Yellow for Rack Side.

4

-

-

... More
Supply ,Installation &Testing of 20 Pair MDF Module Frame with lockable facility.

1

-

-

... More
Supply ,Installation &Testing of 10 Pair disconnection Module for 100 pair MDF.

1

-

-

... More
10 pair Telephone Riser Cable .

1

-

-

... More
Supply & drawing of Cat.5 A 4Pair UTP Cable 305m Blue, CM for Back Bone.

2

-

-

... More
Supply & Fixing of SOCKET RJ45 CAT5 Non-SHUTTERED KSTONE Grey for Back-Bone.

4

-

-

... More
supply installation and testing of Rack 19'' 12 U 500W/300D lockable and removable side panels, with PDU.

1

-

-

... More
CCTV SYSTEM:

-

-

-

... More
Supply Installation testing commissioing of 540 TVL Day/Night Dome cameras with sensitivity of minimum 1.6 lux (Color) and 0.01 lux(B&W). The cameras shall use the1/3-inch interline transfer CCD sensor and shall have a 2.8 to 12mm varifocal lens. The Cameras shall be EN/UL Listed asper the specifications -(in P&G Area , Lift Lobby and admin office)

4

-

-

... More
Supply Installation testing commissioing of 540 TVL CCD Camera with minimum lux level of 0.01 lux. The cameras shall use 2.9 to 8mm varifocal lens. Electronic Shutter range of 1/50 - 1 / 100,000 sec. The Cameras shall be EN/UL Listed asper the specification-(in Plant room and passage)

4

-

-

... More
Supply Installation testing commissioing of 540 TVL CCD True Day/Night Camera with minimum lux level of 0.001 lux. The cameras shall use 2.7-13.5 mm varifocal lens. Electronic Shutter range of 1/50 - 1 / 100,000 sec. The Cameras shall be EN/UL Listed asper the specification.(External Perhaperi)

1

-

-

... More
Outdoor Aluminium housing Small, Sleek, Contemporary Design High Reliability Die-Cast Construction Tamper-Proof Hardware, with Heater/Blower, Sun Shroud, Meets IP66 and NEMA Standards. UL,CE, FCC certified with Inbuilt power adapter for cameras asper the specification.

1

-

-

... More
Supply, installation, testing & commissioning of UL listed DVR 16ch with 6Slots for HDD and DVD writer,Compression H.264,Outputs CVBS (BNC),HDMI, VGA ,4 audio input,Control RS 485 and RS 232,16 Alarm Input ,Video Output Loop Through,ESata connector for backup device,One front and one rear USB connector for mouse or USB memory device,Support Joystick Mode Manual, motion detection, scheduled, alarm,Alarm handling Motion detection Supports NAS

1

-

-

... More
Supply, installation, testing and commissioning RG11 Cable in existing Conduit/raceway/cable tray with clamp/sadles/tie as per technical specification etc complete ar required .

150

-

-

... More
Supplying and fixing of 25 mm steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.

100

-

-

... More
SITC of 42" LED 1920 x 1080 HD Display System

1

-

-

... More
SANITARY FIXTURES : Note: All porcelain sanitary ware, CP fittings and accessories as specified below shall be supplied by the contractor with complete accessories as per the approval of the Architect/Client at site. Contarctor will include providing and fixing of all other accessories, like silicon, extension pieces etc. fixing devices in the respective item rates for the same in his tender. No extra payment on this account will be admissible under any circumstances.

-

-

-

... More
Providing , fixing, testing and commissioning of of white vitreous china European type water closet floor/ wall mounted with concealed P trap and low volume concealed type flushing cistern with internal fittings made of high grade plastic and non-corrosive metal, matching polypropelene seat and cover, CP brass hinges rubber buffers, with accessories, CI/MS concealed brackets painted with two or three coats of enamel paint of approved shade over a coat of primer. CP brass screws and wooden cleats, including cutting and making good the wall and floors wherever required.

2

-

-

... More
Providing , fixing, testing and commissioning of C.P. hand spray (health faucet) with push button control and flexible hose connection with C.P. holder for hand spray complete in all respects.

2

-

-

... More
Providing , fixing, testing and commissioning of CP brass Toilet Paper Holder fixed to PVC raw plug with SS screws, making holes in walls & making good.

2

-

-

... More
Providing , fixing, testing and commissioning of Under/Over counter wash basin with C.I. brackets, 32 mm C.P brass/ PP waste fitting and C.P brass/ PP waterless Bottle trap - of standard pattern, including supply of CI Bracket fitting, flexible pipe with Supply of painting of fitting, cutting and making good the walls wherever required.

5

-

-

... More
Providing , fixing, testing and commissioning of single lever pillar tap for wash basin.

5

-

-

... More
Providing , fixing, testing and commissioning of senor pillar tap for wash basin.

1

-

-

... More
Providing , fixing, testing and commissioning of white vitreous china Urinal basin of standard size C.P brass flush pipe, spreaders with unions and clamps (all in C.P brass) with waste fitting & waterless PP bottle trap (if required), with outlet grating, Infra-Red based electronic flushing system operated on 6V DC (4AA) battery for urinals comprising of solenoid valve, concealed built in strainer & flow mechanism piping, flush mounted sensors with all accessories & fittings complete in all respect in fully operational condition and other couplings in C.P brass including painting of fitting and cutting and making good the walls and floors wherever required.

1

-

-

... More
Providing , fixing, testing and commissioning of of glass urinal partition as per interior drawing including providing & fixing concealed CI bracket, cutting and making good, complete in all respect.

1

-

-

... More
Providing , fixing, testing and commissioning of Stainless steel AISI 304 (18/8) Pantry sink with CI/MS (Painted) bracket and stainless steel plug 40 mm including drain connection with PP 40/50 mm Dia pipe, painting of fittings and brackets, cutting and making good the walls wherever required:

1

-

-

... More
Providing , fixing, testing and commissioning of of 15 mm CP brass wall mounting single hole mixing fitting for sink with swinging and swivel spout complete including cutting and making good the walls wherever required.

1

-

-

... More
Providing , fixing, testing and commissioning of C.P brass Angular stop cock with wall flange (Angle Valve) for basin mixer,health faucet, Shower & WC etc. of approved quality complete in all respect.

10

-

-

... More
Providing , fixing, testing and commissioning of SS finished Robe hook fixed to wall / door with wooden cleats and SS screws including cutting and making good the wall wherever required.

4

-

-

... More
Providing , fixing, testing and commissioning of of SS liquid soap Dispenser with Metallic Bottle complete including cutting and making good the wall wherever required.

4

-

-

... More
Providing , fixing, testing and commissioning of fully automatic "No tough" recessed SS brushed finish hand drier with paper dispencer and waste bin suitable to operate on 230 volts, single phase, 50 Hz AC power supply complete with brackets or required fixing arrangeements for fixing including cutting and making good the walls wherever required and connection.

2

-

-

... More
Providing , fixing, testing and commissioning of adjustable support arm (Toilet safety rails) with non slip rubber base of Aluminium work for physically challanged persons complete accessories complete as required including cutting and making good the wall and floor as required.

2

-

-

... More
Providing , fixing, testing and commissioning of Stainless steel AISI 304 Handrail for fix mounting as per the requirements of ADA for physically challanged persons complete accessories complete as required including cutting and making good the wall and floor as required.

1

-

-

... More
INTERNAL DRAINAGE

-

-

-

... More
Providing, fixing, and testing of uPVC SWR type B pipes and fittings, Push fit type, as per IS 13592 and fittings as per IS 14735 with factory fitted lip ring and complete as per specification and as required Vertical Soil, Waste, Vent/ASP Pipe fixing at wall / ceiling level supported by Painted M.S angle and G.I clamp with rubber line brackets & hangers etc. duly epoxy coated. cutting, chases / holes in floors / walls / slab.

-

-

-

... More
75 mm dia

8

-

-

... More
110mm Pipe dia

30

-

-

... More
Providing, laying, jointing and testing uPVC pipes conforming to IS 4985 (6 kg/cm2) including injection moulded fittings with bosses e.g. tees, bends, couplings, adapters etc. and jointing with solvent weld joint, chasing, making wall good with cement and concrete complete as per specification and as required indirect waste Pipe.

-

-

-

... More
40 mm dia.

30

-

-

... More
50 mm dia.

10

-

-

... More
Providing, fixing and testing of uPVC P or S trap having 50mm water seal, including jointing, making good the walls, floors etc., complete of nominal size - 110x110mm outlet

14

-

-

... More
Providing, fixing, testing & commissioning of uPVC inlet fitting with maximum 3 inlets 40, 50 OD size, fixed to uPVC traps including solvent weld joint/rubber ring joint complete with all civil work.

14

-

-

... More
Providing ,fixing, testing and commissioning of combination of 110 x 110 mm elbow and 110 x 50 mm eccentric reducer uPVC waste (as Floor Drain) with extension piece, elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to floor trap

2

-

-

... More
Providing ,fixing, testing and commissioning of heavy duty SS grating of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for floor drain and floor trap: Size 100 mm x 100 mm

10

-

-

... More
Providing and fixing in position square stainless steel cockroch trap consisting of 0.45 mm thick inner and outer cup and 1.0 mm thick top grating (Jali) with ring to be fixed inside ‘P’ traps with cement concrete. (for Floor Trap) - As per approved sample: Size 125 mm x 125 mm

10

-

-

... More
Providing & fixing clean out plug with suitable openable fittings, male threaded joint with threaded socket fixed to pipe, joints as required complete in all respects : 110 mm dia

2

-

-

... More
Supplying, fabrication and fixing of MS grating fabricated from 16mm square rod/ 20x4 mm MS flat having 20mm clear spacing, one piece upto 1000mm long, fixing angle iron frame 25x25x4 mm angle with hold fast at 1m c/c in cement concrete and hinged grating madeout of 35x5 mm flats in 1m length inclusiveof welding, griding etc. & including redprimer & two coats of enamel paint and setin cement mortar 1 : 3 (1 cement : 3 coarse sand) complete in all respect 350 mm wide.

5

-

-

... More
Supply, installation, testing & commissioning of G.I. Pipes Class 'C' (Heavy grade) conforming to I.S. 1239 with G.I. Fittings conforming to IS : 1879 such as tees, crosses, plug, socket, elbows, reducers, flange, check nut, flanges & clamps, hanger, structural steel supports as required / directed at Site including cutting, making good the walls and painting with two or more coats of synthetic enamel paint of approved quality and shade over a coat of approved priming coat as directed by the Project Manager etc. (For Sump riser) 80 mm dia GI Pipe for Sump pump

30

-

-

... More
Providing, laying, jointing and testing uPVC pipes conforming to IS 4985 (6 kg/cm2) including injection moulded fittings with bosses e.g. tees, bends, couplings, adapters etc. and jointing with solvent weld joint, C.I gratings over pipes of bell mouth construction with epoxy painting for terrace, fixing at wall / ceiling / floor level supported by clamp & hangers etc. inside duct / suspended from floor under false ceiling.The Pipes will be supported by either rubber lined G.I. U strap clamps on 50 x 50 x 5 mm MS slotted angle duly painted (for a group of pipes) or G.I. rubber lined split clamp (for independent pipes). The cost will include all support arrangements with any minor chasing / chopping / civil masonry work. commissioning of all pipes lines as per drawings and specifications and as directed by Project Manager at site.

-

-

-

... More
75 mm dia

6

-

-

... More
110 mm dia

6

-

-

... More
160 mm dia

60

-

-

... More
WATER SUPPLY (INTERNAL)

-

-

-

... More
Providing, fixing, testing and commissioning of PP-r (Polypropylene Random) glass fibre compound 3 / 5 layer food grade pipe of PN – 16 in accordance with DIN EN 21003 for Domestic, Flushing & Hot water application with corresponding hot fusion welded, PR-r fittings like Tees, elbows, sockets, Reducers, Unions, brass wall adaptors (both male and female) etc. Cutting and making good the walls, floors, RCC work etc. cutting chase and filling the same with cement concrete 1:3:6 (1 Cement :3 Coarse sand : 6 graded stone aggregate 20 mm nominal size ) or cement Mortar (1 Cement : 4 Coarse sand) as required. . (Concealed Piping)

-

-

-

... More
15 mm dia

60

-

-

... More
20 mm dia

25

-

-

... More
25 mm dia

15

-

-

... More
Providing, fixing, testing and commissioning of PP-r (Polypropylene Random) glass fibre compound 3 / 5 layer food grade pipe of PN – 16 in accordance with DIN EN 21003 for Domestic, Flushing & Hot water application with corresponding hot fusion welded, PR-r fittings like Tees, elbows, sockets, Reducers, Unions, brass wall adaptors (both male and female) etc. supported by clamp & hangers etc. inside duct / suspended from floor under false ceiling.The Pipes will be supported by either rubber lined G.I. U strap clamps on 50 x 50 x 5 mm MS slotted angle duly painted (for a group of pipes) or G.I. rubber lined split clamp (for independent pipes). The cost will include all support arrangements with any minor chasing / chopping / civil masonry work. commissioning of all pipes lines as per drawings and specifications and as directed by Project Manager at site.. (For Shaft and Terrace)

-

-

-

... More
25 mm dia

20

-

-

... More
32 mm dia

60

-

-

... More
50 mm dia

45

-

-

... More
Providing, fixing, testing and commissioning of forged brass ball valve (PN 10) with hard chrome plated ball inside PTFE (Teflon) seat & ring with chrome plated centre handle withfemale BSP threads complete in all respects.

-

-

-

... More
15 mm dia

1

-

-

... More
20 mm dia

2

-

-

... More
25 mm dia

2

-

-

... More
32 mm dia

1

-

-

... More
Providing, fixing, testing and commissioning of cast iron wafer type butterfly valves (PN 16) as per IS:13095, with SS disc, shaft, seating rings, internal fastening, nitrile rubber lining, nuts, bolts including transporting to worksite, 3 mm thick rubber gaskets etc. including testing, Complete as per drawings & directions of the Project Manager.: 50 mm dia

2

-

-

... More
Providing, fixing, testing and commissioning of C.I. double acting air release valve of approved quality with bolts, nuts, rubber insertion, tail pieces, tapers, with ball valve etc. as required complete.: 25 mm dia

3

-

-

... More
Providing ,fixing, testing and commissioning of IP 67 (Weather Proof /Aluminum casing with positioner to indicate the valve position with key type manual overdrive) Motorized Butterfly valve / Ball valve of following dia with limit switch arrangement for filling of over head water tank complete with high and low level float type sensors to control the valve .The sensors shall be installed in over head tanks. The sensors will close the valve when water level is high in over head tank and open the valve when over head water tank level is low. The system should be complete in all respects with control panel indicating the position of valve i.e. open /closed with pressure switches at pump discharge, accessories like wiring / conduting / flanges, nut bolts etc. All the control switchgears, connections, wiring, integration etc. should be included in the quote. No additional payment shall be charge for any work against this item.: 25 mm dia

1

-

-

... More
Providing ,fixing, testing and commissioning of PVC / HDPE three layer UV protected Circualr tank of 2000 Ltrs capacity with all required inlet, internconection outlet, drain provision as per requirement and direction of engineer incharge.

1

-

-

... More
Providing ,fixing, testing and commissioning of PVC / HDPE three layer UV protected Circualr tank of 5000 Ltrs capacity with all required inlet, internconection outlet, drain provision as per requirement and direction of engineer incharge.

1

-

-

... More
WATER SUPPLY EXTERNAL

-

-

-

... More
Providing,laying and jointing in position PE-80 HDPE pipe confirming to IS: 4984 and suitable working prssure of 12.5 bar and tested at 20 bar pressure with all fitting and accessories e.g - coupling, Tee, bends, reducer, flanged tail pieces etc jointing as per manufacturer specification/instruction. Cost shall inclusive of excavation upto required depth, filling sand alround, consolidation each deposited layer by ramming, watering etc, backfilling and disposing of surplus excavated soil as directed by Project Manager complete in all respect. (External Water Supply).

-

-

-

... More
25 mm Dia

70

-

-

... More
50 mm Dia

80

-

-

... More
65 mm Dia

30

-

-

... More
Providing and fixing truck fill point consisting of 65mm dia. Water filling point with butterfly valve and NRV having 65mm dia brass plug including suitable locable housing of approved design.

1

-

-

... More
Supplying, fixing, jointing and testing in position the following heavy class (Class C) GI pipes conforming to IS:1239 cut to required lengths including all necessary fittings (All fittings shall confirm to IS:1879 - part 1 to 10) and specials such as bends, tees, unions, reducers, flanges & plugs etc including testing of pipes at twice of working pressure. Cost shall be inclusive of providing two coats of synthetic enamel paint of approved shade on exposed pipes, over a coat of red oxide , primer. Cost shall also inclusive of excavation upto required depth, filling sand alround, consolidation each deposited layer by ramming, watering etc, backfilling and disposing of surplus excavated soil as directed by Project Manager complete in all respect. ( For Garden Hydrant)

-

-

-

... More
25 mm dia

30

-

-

... More
50 mm dia

150

-

-

... More
Providing and fixing ball valve (PN 10) with hard chrome plated ball inside PTFE (Teflon) seat & ring with chrome plated centre handle withfemale BSP threads complete:in all respects: 25mm dia nominal bore

7

-

-

... More
Providing and fixing 20 mm brass QRQC hydrant valve with PVC lid complete in all respects.

7

-

-

... More
Providing and fixing 20 mm brass keys for hydrant valve complete in all respects.

7

-

-

... More
Providing, fixing, testing and commissioning of cast iron double waffer type flanged butterfly valves (PN 16) as per IS:13095, with SS disc, shaft, seating rings, internal fastening, nitrile rubber lining, nuts, bolts including transporting to worksite, 3 mm thick rubber gaskets etc. including testing, Complete as per drawings & directions of the Project Manager.

-

-

-

... More
50 mm dia

2

-

-

... More
65 mm dia

1

-

-

... More
Constructing masonry chamber with 75 class designation bricks in cement mortar 1:5 (1 cement : 5 coarse sand) for ball valve with CI surface box 100 mm top dia 160 mm bottom dia and 180 mm deep (inside) with chained lid and RCC top slab 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1 : 5 : 10 mix (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 : 3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement and outside plaster finished rough complete as per standard design, including fixing of SFRC heavy duty Manhole cover and frame in 150 mm thick cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) including centering, shuttering, excavation, refilling and disposal of surplus earth as directed complete in all respects. (Include the cost of Manhole cover and frame): Inside size 450 x 450 mm & 600 mm deep

2

-

-

... More
Providing & fixing digital type water meter with direct reading dial in KL with all internal parts in gunmetal or brass, butterfly valve, strainer, flanged distance piece for easy removal in future, Bourden type pressure guage and isolation cock including necessary test certificate for the meter from local authorities.

-

-

-

... More
50 mm dia for Domestic Water Supply Riser

1

-

-

... More
50 mm dia for Municipal/Panchayat Inlet & Irrigation Water Supply

2

-

-

... More
Providing, fixing, testing and commissioning of multistage, horizontal/vertical, centrifugal, 2 pole, 50 HZ, AC pumps incorporating C.I. casing and frame, stainless steel shaft, bronze / SS impeller, TEFC induction motor directly coupled to the pump, IP44 protection, class B insulated, C.I. body, hydraulically and dynamically balanced to give vibration free operation, with mechanical seal arrangement, fixed on a base plate with suitable vibration eliminator pads complete with level controller, electrical control panel / starter panel, necessary wiring / Cabling, pressure gauge, valves, vibration eliminators on the delivery side and strainer on suction side, including non-return valve and isolating valves on suction and delivering sides as required, including suction, delivery headers and interconnecting piping (G.I. Heavy Class) complete in all respects. -

-

-

-

... More
Domestic Trasfer Pumps For Overhead Tank Filling; Flow rate (each) = 2.0 M3 /hr; Pumping Head = 35 m; 1 Set (2 Nos Pumps. 1 Working + 1 Standby); Location : Plumbing Plant Room

1

-

-

... More
Making connection of Municipa/Panchayat water line with existing Muncipal/Panchayat line including excavation, construction of valve chamber & making good the walls, floors, road etc. Proper water proofing to ensure no. ground water seepage in the manhole: For upto 100mm dia pipe

1

-

-

... More
EXTERNAL SEWAGE & DRAINAGE WORKS

-

-

-

... More
Excavating trenches in all kind of soil of required width for pipes, cables etc including excavation for socket and dressing of sides ramming of bottoms depth upto 1.50 m including timbering, shuttering, centering etc. as required getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil within the site premises as specified by Project Manager: Pipes cables etc exceeding 80 mm dia but not exceeding 300 mm dia.

180

-

-

... More
Extra for excavating trenches for pipes, cables etc. in all soils for depth exceeding 1.50 m (Rate is extra over corresponding basis item for depth upto 1.5 m)

100

-

-

... More
Providing and laying non pressure NP2 class RCC pipes S & S jointed with stiff mixture of cement motrar in the proportion of 1 : 2 (1 cement : 2 fine sand) including testing of joints etc. complete

-

-

-

... More
150 mm dia

50

-

-

... More
200 mm dia

100

-

-

... More
250 mm dia

50

-

-

... More
Providing and laying cement concrete 1:5:10 (stone agg. 40 mm nominal size) in bedding & haunches of RCC pipes.

-

-

-

... More
150 mm diameter RCC Pipe

45

-

-

... More
200 mm diameter RCC Pipe

100

-

-

... More
250 mm diameter RCC Pipe

50

-

-

... More
Providing & fixing square-mouth uPVC gully trap complete with grating, brick masonry chamber with bricks of class designation 75 in cement mortar 1:5 (1 cement : 5 coarse sand) inside plaster above trap 12mm thick m cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement outside plaster 12mm thick in cement mortar 1 :3 ( 1 cement : 3 coarse sand) 10cm thick foundation concrete 1 : 5 : 10 mix (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) space between chamber, and trap filled with cement concrete 1:2:4 (1 cement : 2 coarses and : 4 graded stone aggregate 20 mm nominal size) and water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg asper standard design. 300 x 300 mm gully trap chamber with 150 x 100 mm 'P' trap with water tight C.I. cover with frame 300 x 300 mm size (inside) the weight of cover to be not less than 4.5 kg and frame to be not less than 2.7 kg as per standard design.

3

-

-

... More
Constructing brick masonry road gully chamber 450 x 450 x 600 mm wtth bricks of class designation 75 in cement mortar 1:5 (1cement : 5 coarse sand), inside cement plastering 12mm thick with cement mortar1 : 3 (1 cement: 3 coarse-sand) finished witha floating coat of neat cement, outside plaster 12 mm thick in cement mortar 1 : 3 (1 cement : 3 coarse sand) 10 cm thick foundation concrete 1 : 5 : 10 mix (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) including 500x450 mm RCC horizontal grating wilh frame fixed in15cm thick cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 grade stone aggregate 20 mm nominal size) including excavation, refilling and disposal of surplus earth as directed by PMC complete as per standard design.

9

-

-

... More
Extra depth for road gully chambers 450 x 450 rnm.

9

-

-

... More
Constructing brick masonry rectangular type manhole with sewer bricks conforming to IS 4885 in cement mortar 1 : 5 (1 cement : 5 coarse sand) inside cement plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, outside plastering with cement mortar 1 : 3 (1 cement : 3 coarse sand) foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size). RCC top slab with 1 : 2 : 4 mix and making necessary channels in cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), inside finished with a floating coat ot neat cement including excavation, refilling and disposal of surplus earth as directed by Project Manager complete as per standard design. 900x800mm upto 1500mm deep with ISI marked steel fiber reinforced concrete (SFRC) manhole cover and frame having hold fasts (Heavy Duty HD-20) 560 mm internal diameter. Extra depth for Rectanguler type manhole as per above item

3

-

-

... More
RAIN WATER HARVESTING SYSTEM Construction of rain water harvesting size 3m dia x 3.5m effective depth for the re-charging of storm water run off including the civil work with following specification [Construction of Chamber].DE-SILTING CHAMBER: Providing and constructing mansonary de-silting chamber 2000mm x 1500mm with 1.0 m effective depth inside with 75 class designated brick work in cement mortar 1:6 (1cement : 6 fine sand) with C.I double seal heavy duty 560mm dia manhole cover (2 Nos.). top slab 1:2:4 mix (1cement : 2coarse sand : 4 graded stone aggregate 20mm nominal size) with minimum 1.5% reinforcement, foundation concrete 1:5:10 (1cement : 5 fine sand:10 grade stone aggregate 20mm nominal size including baffle wall, necessary excavation, back filling and disposal of surface earth. Complete with inlet, outlet and overflow arrangement. Foot rest @400mm c/c, grating of required size with 16mm sq.bars and frame @20mm clear spacing fixed at month of pipe as per site conditions and direction of Project Manager ; DRILLING: Drilling percolation borehole 200mm dia with reverse rotary method in all types of soil upto 40mm depty including cost for mobilization of rig and making good the area upon completion of work. Contractor shall arrange for all necessary tools, water and consumable and laying for drilling; Providing and laying pea gravel all around the casing pipe; 160 mm dia slotted UPVC pipe of 6 Kg/cm2 - 35 m -40m or as per site sub-strata or set as per direction of Project Manager; 160 mm dia UPVC blind pipe of 6 Kg/cm2; RAIN WATER HARVESTING WELL FILTRATION CHAMBER: Providing and constructing rain water harvesting well/filtration chamber of size 3m dia x 3.5m eff. depth inside with 75 class designated brick work in cement motor 1:6 (1cement : 6 fine sand) with 560mm dia C.I double seal medium duty manhole cover with top slab 1:2:4 mix (1cement : 2 course sand :4 graded stone aggregate 20mm nominal size) with minimum 1.5% reinforcement , foundation concrete 1:5:10 (1cement : 5 fine sand and 10 graded stone) aggregate 20mm nominal size including 300mm duty. Boulder 10-20mm, 300mm duty, gravel 5-10mm size, 300mm depth coarse sand 1.5-2.0mm including necessary excavation, back filling and disposal of surface earth complete with inlet, outlet, overflow arrangement pvc coated Foot Rest, 100mm dia deep holes @500mm c/c to be provided 1200 c/c above the bottom of wall, 100mm C.I vent pipe -2m height with cowls. Rate shall include excavation, back filling and all other operations necessary for completing the job.

1

-

-

... More
Providing and constructing Soak pit (2.0 Mtrs. Dia) with septik tank of size 3.0 m x 2.0m and eff. depth 2.0 m inside with 75 class designated brick work in cement motor 1:6 (1cement : 6 fine sand) with 3 Nos. 560mm dia C.I double seal medium duty manhole cover with top slab 1:2:4 mix (1cement : 2 course sand :4 graded stone aggregate 20mm nominal size) with minimum 1.5% reinforcement , foundation concrete 1:5:10 (1cement : 5 fine sand and 10 graded stone) aggregate 20mm nominal size including necessary excavation, back filling and disposal of surface earth complete with inlet, outlet, overflow arrangement pvc coated Foot Rest, 100mm C.I vent pipe -2m height with cowls.

1

-

-

... More
FIRE FIGHTING WORKS

-

-

-

... More
FIRE PUMPS, EQUIPMENT, PIPING, VALVES & ACCESSORIES : Electric Motor Driven Hydrant Pump (Location - Fire/Plumbing Plant Room) : Supplying, installing, testing and commissioning of Fire authority approved, factory assembled and tested Electrical driven fire pump suitable for automatic/ manual operation consisting of the following: Horizontal end suction, high pressure single/ multistage centrifugal type fire pump capable of delivering 1620 LPM (27 LPS) against a total head of 60 M while running at 2900 RPM complete with mechanical seal, proper connection to suction and delivery line, and including 100 mm bypass arrangement for testing of pumps, having a name plate indicating suction, delivery, head, discharge, stages, RPM and direction of rotation; Pump shall be capable of furnishing not less than 150% of rated capacity at a head not less than 65 % of rated head. The shut off head shall not exceed 120% of rated head; Squirrel cage, induction motor, TEFC type, efficiency class. eff-1, suitable for 415 + 10%V, 3 phase, 50 Hz, AC supply, of suitable HP rating for the above pump with a synchronous speed of 2900 RPM conforming to IP 55 protection & class 'F' insulation. The motor shall conform to IS 12615 : 2004 and IS 325 : 1978 (up to date) with flexible coupling and coupling guard; Common base plate for mounting pump and motor fabricated of mild steel channel as per manufacturer's recommendation with heavy duty Anti Vibration pads (6 Nos., heavy duty); Flexible Coupling and coupling guard for direct coupling of pump and motor; Drain Pipe with Valve (50 mm dia) (For independent testing respective pump); Main Fire Pump; Discharge : 1620 LPM (27 LPS) ; Pumping Head : 60 M; Motor KW (Approx) : 35 KW/As per manufacturer recommendation. Rate should include interconnection fire survival cables and foundation bolts, grouting of Foundation bolts and other accessories required.

1

-

-

... More
Diesel Engine Driven Fire Pump [Stand by pump] (Location -Fire/Plumbing Plant Room) : Supplying, installing, testing & commissioning of fire authority approved, factory assembled and tested Diesel Engine driven fire pump suitable for automatic/manual operations consisting of the following : Horizontal end suction, high pressure single centrifugal type fire pump capable of delivering 1620 LPM (27 LPS) against a total head of 60 M while running at 1500 RPM complete with mechanical seal, proper connection to suction and delivery line, and including 100 mm bypass arrangement for testing of pumps, having a name plate indicating suction a delivery head, discharge, stages, RPM and direction of rotation; Heat Exchanger cooled diesel engine of required BHP or as per manufacturer recommendation at 1500 RPM for the above pump complete with standard accessories & suitable cooling system as described in specifications; Common base plate for mounting pump & engine of required strength manufactured out of M.S. channels as per manufacture's recommendation with heavy duty Anti Vibration pads. (Cushy foot) (8 nos., heavy duty); Flexible Coupling & coupling guard for direct coupling of engine & pump; 1 No. minimum 8 hours capacity day oil storage tank fabricated from 3 mm thick M.S. plates. Tank shall be provided with inlet, outlet, overflow, air vent, drain connections, filling connection & magnetic level indicator. Tank shall be mounted on a suitable steel structure (Painted with 2 coats of red oxide paint). Tank shall be provided with epoxy coat from inside & two or more coats of synthetic enamel paint outside over two coats of red oxide primer. Diesel storage tank shall be double skin; 12 volts 180 AH lead acid battery (12 volts - 1 Nos) with boost/Trickle charger for starting the engine automatically complete as required; Diesel Engine driven pump of: Discharge : 1620 LPM (27 LPS) ; Pumping Head : 60 M; Engine HP (Approx) : 40 HP/ As per manufacturer recommendation; Jockey Pump :- Rate should include inter connecting fire survival cables & foundation bolts, grouting of Foundation bolts and other accessories required. (Common for Hydrant & Sprinkler System)

1

-

-

... More
Electrical Motor Driven Jockey Pump (Location - Fire/Plumbing Plant Room) : Supplying, installing, testing & commissioning of fire authority approved, factory assembled and tested electrically driven Jockey pump suitable for automatic/manual operation consisting of the following: Vertical multistage jockey pump having SS body S.S. impeller, stainless steel shaft with mechanical seal capable of delivering 180 LPM against total head of 60 M while running at 2900 RPM complete. The system shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side including bypass arrangement (with 50 mm GM stop valve and up to 5 meter G.I. class 'C' pipe) for testing of working of the pumping set as required. The pump should meet the recommended requirement and must be approved by the local fire authority; Squirrel cage induction motor suitable for 415 + 10%V, 3 phase, 50 Hz, AC supply of suitable HP rating for the above pump with asynchronous speed of 2900 RPM T.E.F.C type having effliciency class eff-1 as per IS 12615 : 2004, connected to pump with flexible coupling and coupling guard ; Common base plate for mounting pump and motor fabricated of mild steel channel as per manufacturer's recommendation with heavy duty 4 Nos. Anti Vibration pads.(Cushy foot); Drain pipe with valve (25 mm dia); Discharge : 180 LPM (3 LPS); Pumping Head : 60 M; App. HP/KW : 5.0 KW/ as per manufacturer recommendation. Rate shall include inter connecting fire survival cables, grouting of Foundation bolts and other accessories required.

1

-

-

... More
Providing, fixing, testing and commissioning of precharged air vessel (size 450 mm dia & 1500 mm height) fabricated shell from 8 mm thick & dished end 10 mm thick M.S. Plate for pressurization of hydrant/ sprinkler system complete with adequate pressure switches (as per design / requirement) with valve to operate as per operating sequences including 25 mm dia drain valve, air release valve with ball cock on top, 80 mm dia flanged inlet with isolating valve duly painted from inside and out side complete as required.

1

-

-

... More
Supply, installation, testing and commissioning of M.S Class 'C' (Heavy Duty) pipes conforming IS:1239/3589, with all necessary fittings like tees, coupling, mechanical tees, strap tees, elbows flanges, reducers, gaskets, nuts, and bolts etc. with welding joints as required including fixing the pipe with necessary structural supports including painting of two coats of synthetic enamel paint over two coats of red oxide primer including all civil breakage and making good the coats of red oxide primer including all civil breakages and making good the same. (Location: Fire Plant Room)

-

-

-

... More
150 mm dia G.I. Pipe

35

-

-

... More
200 mm dia (6 mm thick) with necessary supports etc. as required.

20

-

-

... More
Providing, fixing, testing & commissioning of flanged end Y-strainer made from C.I body having SS filter mesh- 200 mm dia

1

-

-

... More
Providing, fixing, testing & commissioning of C.I Butterfly valve conforming to IS : 13095 with flanges fittings, nuts, bolts and washers complete for following sizes :- [PN 10 rating (10 kg/cm2 pressure rating)].

-

-

-

... More
200 mm dia

2

-

-

... More
150 mm dia

7

-

-

... More
100 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
50 mm dia

2

-

-

... More
Providing, fixing, testing & commissioning of C.I dual plate non-return valve [PN 10Rating (10 kg/cm2 pressure rating)] complete with 2 nos. matching flanges, rubber insertion, with nuts, bolts and washers etc of following sizes .

-

-

-

... More
150 mm dia

2

-

-

... More
80 mm dia

1

-

-

... More
50 mm dia

1

-

-

... More
Providing & fixing dial type (100 mm dia) SS body pressure gauge with isolation ball valve suitable for working pressure of 150 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required. having calibration of 0-10 Kg/cm2.

6

-

-

... More
Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45oC temperature, working pressure 10 Kg/cm2 and test pressure 15 Kg/cm2 for :-

-

-

-

... More
150 mm dia

4

-

-

... More
100 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
Providing, fixing, testing & commissioning of M.S. class 'C' diesel pump exhaust pipe (80mm) including all fittings like bends, tee, clamps/structural steel support of suitable dia for the engine . The insulation of the exhaust pipe shall be carried out with rock wool with specific gravity of 100kg/cm2 and cladded with 22 gauge aluminium sheet.

20

-

-

... More
ELECTRICAL WORKS (Fire Fighting)

-

-

-

... More
Fire Fightimg Control Panel: SITC of following fire fighting panel suitable for 415 V, +/- 10% Volts, 3 phase, 4 wires, 50 Hz power distribution system. The panel shall be free standing floor mounting sheet metal enclosed dust and vermin proof conforming to IP-52, compartmentalized design, fabricated out of 14 SWG sheet steel, painting, earthing numbering, danger plate as per specifications and drawings , flush front with Aluminium busbars, separate earth bus bars of 40 x 5 mm (Aluminium) to be provided throughout the length of the panel. The incoming and outgoing feeder breakers, fuses, indicating lamps etc shall be accommodated in a modular multitier arrangement. The painting shall be done as per relevant IS codes/as specified in the specifications. Adequate size cable alley shall be provided all round the panel and in the back for each cable bending and termination. The panel shall be fabricated by TAC/Fire authority approved vendor. The outgoing feeders inside the panel shall be connected through solid bus bars. Flexible cable links are not acceptable; Bus bars shall be provided with heat shrinkable sleeves and shall be colour coded. The panels shall be suitable for cable entry from top. The panels shall be fabricated after the approval of fabrication drawings; All wires shall be PVC insulated and cables used will be XLPE insulated. 2 Nos. earthing terminals shall be provided for 3 phase, 415 V, 50 HZ supply system. M Lifting hooks shall also be provided in case of large panels. Cadmium plated hardware shall be used in fabrication of Panels; Fire Fighting Panel: Incoming : One (1) No. 200A TPN MCCB (25 KA); One (1) No. Multifunction Meter for measurement of voltages, current and frequency (ELF-3254 of conzerv or approved Equivalent) with suitable ratio CTs and back up SP MCB/Fuses; 1 Set (3 Nos.) of phase indication lamps LED Type with backup SP MCB; Three (3) Nos. of indication lamps for ON/OFF & Trip with backup SP MCB- Busbar :- 250A, 25KA,TPN Aluminium busbar insulated with PVC Colour coded heat shrinkable sleeve; Separate earth busbar of 50X6mm Aluminium shall be provided. Outgoing: One (1) Nos. 160 A TP+N MCCB (35kA); One (1) Nos. 63A 4P MPCB; One (1) No. DOL Starters complete with over load relay with separate single phasing protection feature, ON/OFF & TRIP, indication lamp, AC3 duty contactors, Auto/Manual selector switch and sufficient nos. of potential free spare contacts, etc. suitable for 40 HP motor as per approved SLD; One (1) No. DOL Starters complete with over load relay with separate single phasing protection feature, ON/OFF & TRIP, indication lamp, AC3 duty contactors, Auto/Manual selector switch and sufficient nos. of potential free spare contacts, etc. suitable for 5.0 HP motor as per approved SLD; Wiring from pressure switch to starter - Lot.; Set of control system to make the system automatic as per functional requirements which is activated with pressure switches as per specifications and complete with all accessories as required.; Interlocking shall be provided so that only one pump starts at a time; The diesel engine driven fire pump shall start automatically in the event of pressure drop beyond preset limit on mains failure or failure of electrical driven pumps to start. AMF logic for starting the diesel engine fire pump with trickle / boost battery charger, DC ammeter Voltmeter, Hooter indication etc to meet the system requirement; One (1) no. pressure switch; Wiring from pressure switch to Diesel engine control panel. Following provisions to be made in the fire panel: Audio visual alarm & indications having disconnect/reset facility with a range of 1/2 km. Annunciator to be provided in the Fire panel with hooter and acknowledge, test and reset PBs. The indication shall come on when electrical driven pump set fails to start on pressure drop or when there is power failure during pressure drop; Facility for mode selection ie auto or manual test & local/remote; Protection features & control cabling; Panel shall be interlocked in such a way when fire pump starts on pressure drop in the header, supply to working chiller and A/c panel is disconnected; Remote indication of ON/OFF/ TRIP shall be provided through potential free contact; Provision of remote starting/ stopping (manual) of the engine shall be made; Sufficient No. of potential free contacts and terminals shall be provided for connecting it to BMS); Note: Contractor shall include in his rate for providing level controller, pressure switches, wiring, cabling from level controller/pressure switch to panel etc. complete as required to operate the system automatic/manual. Pump shall be protected against running dry. The Control panel should meet the requirement of Local Fire Authority norms and shall be manufactured as per approved technical data sheet of pumps. Fire Fighing Panel described as above and as per SLD.

1

-

-

... More
Supply, installation, testing & commissioning of following sizes of 1100 V grade XLPE insulated PVC inner & outer sheathed, Aluminium, fire survival armoured cables, as per site conditions.

-

-

-

... More
3.5C x 120 Sq.mm

40

-

-

... More
4C x 50 Sqmm

1

-

-

... More
3C x 16 Sqmm

40

-

-

... More
3C x 10 Sqmm

1

-

-

... More
4C x 16 Sqmm

1

-

-

... More
Copper Conductor Armoured fire survival Control Cables :

-

-

-

... More
4C x 2.5 Sq.mm

50

-

-

... More
5C x 2.5 Sq.mm

1

-

-

... More
Cable Termination: Supply & making end termination with brass double compression glands for the following XLPE insulated, PVC sheathed & armoured 1100 V grade Aluminium cable including cost of crimping lugs/ferrules, compression glands, solder, cable sockets, insulation tape etc complete as required.

-

-

-

... More
3.5C x 120 Sqmm

4

-

-

... More
4C x 50 Sqmm

1

-

-

... More
3C x 16 Sqmm

2

-

-

... More
3C x 10 Sqmm

1

-

-

... More
4C x 16 Sqmm

1

-

-

... More
Cable Termination : Suitable for Copper Conductor Armoured Control Cables :

-

-

-

... More
4C x 2.5 Sq.mm

8

-

-

... More
5C x 2.5 Sq.mm

1

-

-

... More
Supply and installation of GI ladder type/perforated type cable trays of the following sizes fabricated out of perforated hot dip galvanised MS sheets of minimum 2mm thick with 75mm flange to be installed horizontally or vertically: Ladder Type Cable Tray

-

-

-

... More
300mm wide

35

-

-

... More
150mm wide

25

-

-

... More
Perforated Type Cable Tray

-

-

-

... More
300mm wide x 50mm x 2mm

10

-

-

... More
150mm wide x 40mm x 2mm

10

-

-

... More
Earthing: Supply, Installation, Testing & Commissioning of the following size of GI strip/wire clamped to wall, cable trays complete as required including interconnection between lengths at joints, all fixing accessories saddles, calmps etc. and other fixing hardware.

-

-

-

... More
50 x 6 mm strip

1

-

-

... More
25 x 6 mm strip

25

-

-

... More
25 x 3 mm strip

1

-

-

... More
8 SWG GI wire

20

-

-

... More
FIRE HYDRANT SYSTEM (INTERNAL) : SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF: 'C' class heavy duty M.S. pipe conforming to IS 1239 including welding/threading, jointing with all fittings like elbows, tees,bends,flanges, tappers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamps & structural steel support including cutting holes and chases in brick work and RCC work and painting with two coats of red oxide primer and two coats of synthetic enamel paint of required shade complete as required. Notes: Pipes upto and 50 mm dia shall be threaded joints, above 50 mm shall be done with Welded joints. Notes: Pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the wall/ floors/sealing, the sleeves with glass wool in between minimum 2 Hrs rated firestop sealant compound at either end, age tested to dafStb guidelines complete as per project manager's requirement or manufacturers reccomendation.

-

-

-

... More
80 mm dia

12

-

-

... More
100 mm dia

20

-

-

... More
150 mm dia

50

-

-

... More
Providing, fixing, testing & commissioning of ISI marked S.S. metal single headed fire hydrant landing valve with Inbuilt pressure reducing valve with flanged inlet, SS spindle controlled 63 mm dia female instantaneous outlet type. CI wheel, SS coupling, blank cap, chain, twist release type lug & all accessories. Conforming to IS:5290. (type A) Including fixing with anchor fastner and flanged tapping from wet riser and providing pressure gauge with gun metal ball valve complete as required.

4

-

-

... More
Providing, fixing testing and commissioning of UL listed 63 mm dia 15 m long non-percolating flexible hose (RRL- type A) as per IS : 636. Type "A" with Stainless steel male & female instantaneous type coupling (IS 903) bound and riveted to hose pipe with copper rivets and 1.5 mm copper wire (For internal).

8

-

-

... More
Providing, fixing testing and commissioning of Stainless steel branch pipe with nozzle of 20 mm nominal bore outlet as per IS:903 suitable to fit with standard instantaneous type 63mm dia coupling ISI marked (IS:903) complete.

4

-

-

... More
Standard Fireman's Axe with heavy insulated handle.

4

-

-

... More
Providing, fixing testing and commissioning of Wall mounting swinging type first aid fire hose reel with drum, hanging bracket, 30.0 Mtr. length x 20 mm dia thermoplast hose reel tubing as per IS:12585 with Stainless steel (SS) shut off nozzle having 6.5 mm dia orifice. The hose reel shall be conforming to IS : 884-1985. Rate shall include 25 mm dia M.S. pipe (heavy class) connection from Riser to hose reel, sockets, nipples, elbows and ball valve (25 mm dia). Drum shall be fixed on adjoining wall by means of 120 mm x 100 mm long fasteners, bolts and nuts including painting. (For internal hydrant system).

4

-

-

... More
Providing & fixing fire authority approved M.S. hose door (size 900 (L) x 2100 (H)) made out of 16 SWG powder coated M.S. sheet Angle frame capable of accommodating fire hose reel, fire hydrant, hose pipe, fittings & accessories. The box shall have a single or double glazed front glass door (with 4 mm thick glass) with lock & key arrangement & shall be painted with Fire red as per IS:5, shade no. 536. (Location : For Internal Hydrant)

4

-

-

... More
Providing, fixing, testing & commissioning of C.I Butterfly valve conforming to IS : 13095 with flanges/grooved fittings, nuts, bolts and washers complete for following sizes :- [PN 10 rating (10 kg/cm2 pressure rating)].

-

-

-

... More
150 mm dia

1

-

-

... More
100 mm dia

2

-

-

... More
80 mm dia

4

-

-

... More
Providing & fixing cast iron air release valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement.

1

-

-

... More
Bourden type Stainless Steel dial type pressure gauge with brass isolation valve and pipe. (For each internal Fire hose cabinet) of dial diameter : 150 mm & Caliberation : 0-15 Kg/cm2

4

-

-

... More
Providing and fixing M.S. structural work fabricated from standard sections, (MS rounds, angles, channels etc.) including cutting to size, drilling, welding, including cost of fasteners, clamps in RCC structural members as directed, including two or more coats of synthetic paint over one coat of primer after surface preparation including cutting and making good walls.

400

-

-

... More
Air cushion tank (air-vessel) 250 mm dia. x 1.0 m high with dished top, made of minimum 6 mm thick MS pipe/plate complete with 25 mm dia. brass air valve (ball valve, pressure gauge type), 25 mm dia brass stop cock, nipple, tees, B46 elbow, pipe and all accessories as required incl. fixing brackets.

1

-

-

... More
FIRE HYDRANT SYSTEM (EXTERNAL): Supply, laying, testing & commissioning of 'C' class heavy duty M.S. pipe conforming to IS 1239 including grooved/threaded jointing with all fittings like elbows, tees,bends,flanges, tappers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamps & structural steel support including cutting holes and chases in brick work and RCC work and painting with two coats of red oxide primer and two coats of synthetic enamel paint of required shade complete as required. Notes: Pipes upto and 50 mm dia shall be threaded joints, above 50 mm shall be done with welded joints. Steel structural supports are included in this items. Pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the wall/ floors/sealing, the sleeves with glass wool in between minimum 2 Hrs rated firestop sealant compound at either end, age tested to dafStb guidelines complete as per project manager's requirement or manufacturers reccomendation.

-

-

-

... More
80 mm dia

15

-

-

... More
100 mm dia

20

-

-

... More
150 mm dia

240

-

-

... More
Providing and applying one coat of 4 mm thick anti rust pipe protection including approved primer as per manufactures specifications and lap of 25 mm to make an impermeable layer on M.S. Pipes in trenches or structural /masonary members complete including surface preparation.

-

-

-

... More
80 mm dia

10

-

-

... More
100 mm dia

25

-

-

... More
150 mm dia

55

-

-

... More
Providing, fixing, testing & commissioning of ISI marked S.S. metal single headed fire hydrant landing valve with Inbuilt pressure reducing valve with flanged inlet, SS spindle controlled 63 mm dia female instantaneous outlet type. CI wheel, SS coupling, blank cap, chain, twist release type lug & all accessories. Conforming to IS:5290. (type A) Including fixing with anchor fastner and flanged tapping from wet riser and providing pressure gauge with gun metal ball valve complete as required.

5

-

-

... More
Providing, fixing testing and commissioning of UL listed 63 mm dia 15 m long non-percolating flexible hose (RRL- type A) as per IS : 636. Type "A" with Stainless steel male & female instantaneous type coupling (IS 903) bound and riveted to hose pipe with copper rivets and 1.5 mm copper wire.

10

-

-

... More
Providing, fixing testing and commissioning of Standard Stainless steel branch pipe with nozzle of 20 mm nominal bore outlet as per IS:903 suitable to fit with standard instantaneous type 63mm dia coupling ISI marked (IS:903) complete.

5

-

-

... More
Providing and plaacing of Stainless steel Standard Fireman's Axe with heavy insulated handle. Tested to 11 KV ISI marked.

1

-

-

... More
Providing, fixing testing and commissioning of Weather proof standard fire hose cabinet (750 mm x 600 mm x 250 mm deep) for yard hydrants made of 16 SWG powder coated M.S. sheet having single or double opening glazed (4.0 mm thick glass) shutter including necessary locking arrangement by allan key, stove enamelled Fire red finish (as per IS : 5, shade no. 536) with " Fire Hose" marked on front, suitable for housing 2 nos. Hose pipe, 1 No. branch pipe & nozzle spanner. Cost shall inclusive of break glass box containing key for the cabinet along with axe hammer.

5

-

-

... More
Providing, fixing, testing & commissioning of C.I Butterfly valve conforming to IS : 13095 with flanges/grooved fittings, nuts, bolts and washers complete for following sizes :- [PN 10 rating (10 kg/cm2 pressure rating)].

-

-

-

... More
150 mm dia

3

-

-

... More
100 mm dia

1

-

-

... More
80 mm dia

6

-

-

... More
Supply, installation, testing and commissioning of S.S four way fire brigade inlet to external hydrant ring /internal hydrant & sprinkler riser/Header with 63 mm dia instantaneous type inlet and 150 mm dia flanges outlet conforming to IS:904 with blank cap and chain including 150 mm dia C.I butterfly valve (PN 10 rating) and wafter type non-return valve complete with nuts, bolts, flanges and complete in all respect. Cost shall include a wall mounted box of M.S. construction (16 SWG) with glass door (4.0 mm thick) to house the above mentioned component.

1

-

-

... More
S.S Metal Two way fire brigade suction hose coupling of (gunmetal draw out connection) with 100 mm dia M.S. 'C’ Class suction pipe with 100 mm dia C.I. foot valve (2 No.). (Pipe max. 10 m long). Cost shall include a wall mounted box of M.S. construction (16 SWG) with glass door (4.0 mm thick) to house the above mentioned component to be connected to static water tank.

1

-

-

... More
S.S Metal fire brigade suction hose coupling of (gunmetal draw in connection) with 100 mm dia M.S. 'C’ Class pipe (Pipe max. 10 m long). Cost shall include a wall mounted box of M.S. construction (16 SWG) with glass door (4.0 mm thick) to house the above mentioned component to be connected at main fire header pipe in fire plant room and external ring main.)

1

-

-

... More
Providing and laying light duty non pressure NP-3 Class RCC pipe S/S jointed with stiff mixture in the proportion 1:2, 300 mm dia R.C.C. Hume pipe for underground hydrant pipe at road crossings including collar pieces and filling inside of pipe with sand complete as required including necessary excavations and back filling and bed concrete. (For road crossing)

30

-

-

... More
Bourden type Stainless Steel dial type pressure gauge with brass isolation valve and pipe. (For each External Fire hose cabinet + tarrace ); Dial Diameter : 150 mm; Caliberation : 0-25 Kg/cm2

6

-

-

... More
Constructing brick masonry chamber with 75 class designation brick work in cement mortar 1:5 (1 cement :5 fine sand) for Butterfly valve/Sluice valve, with FRP medium duty manhole cover fixed in concrete slab 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size), necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand :10 graded stone aggregate 40 mm nominal size) and 12 mm thick inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement complete as per standard design - 1200 x 1200 x 1500 mm internal dimensions

1

-

-

... More
Providing and fixing M.S. structural work fabricated from standard sections, (MS rounds, angles, channels etc.) including cutting to size, drilling, welding, including cost of fasteners, clamps in RCC structural members as directed, including two or more coats of synthetic paint over one coat of primer after surface preparation including cutting and making good walls (For structural work other than pipe supports).

500

-

-

... More
SPRINKLER SYSTEM: Supply, laying, testing & commissioning of 'C' class heavy duty M.S. pipe conforming to IS 1239 including grooved/threading, jointing with all fittings like elbows, tees,bends,flanges, tappers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamps & structural steel support including cutting holes and chases in brick work and RCC work and painting with two coats of red oxide primer and two coats of synthetic enamel paint of required shade complete as required. Notes: For M.S. pipes upto and 50 dia shall be used forged fittings with threaded joint, above 50 mm shall be done with welded joint. Steel structural supports are included in this items. Pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the wall/ floors/sealing, the sleeves with glass wool in between and minimum 2 Hrs rated firestop sealant compound at either end, age tested to dafStb guidelines complete as per project manager's requirement or manufacturers reccomendation.

-

-

-

... More
150 mm dia

1

-

-

... More
100 mm dia

5

-

-

... More
80mm dia

5

-

-

... More
65mm dia

125

-

-

... More
50mmdia

70

-

-

... More
40mmdia

20

-

-

... More
32mm dia

25

-

-

... More
25mm dia

145

-

-

... More
Providing, fixing, testing and commissioning of 100 mm dia Cast Iron/Ductile installation control valve assembly (test pressure should not be less than 10.0 Kg/Sq.cm) with flanges, nut, bolts & gasket complete with pad locking arrangement, vertical wet alarm valve with hydraulic alarm motor & gong, 2 nos. pressure gauges as per manufacturer recommendation with ball valves, 15 mm dia test valves, 50 mm dia drain valve with all necessary accessories.

1

-

-

... More
Providing, fixing, testing and commissioning of 150 mm dia Bourden type, Stainless Steel dial type pressure gauges for sprinkler system including ball valve and pipe having caliberation of 0-10Kg/cm2.

2

-

-

... More
Providing, fixing, testing and commissioning of Quick Response 15 mm dia quartzoid bulb type Stainless steel sprinkler head All sprinklers shall be chrome finish / powder coated except for conceled. The conceled sprinkler shall be brass finish. The cover plate of concealed sprinkler shall be factory painted at manufacturers work and the shade be conformed prior to application on the cover plate. The sprinkler shall be either pendent or upright type/side wall and shall not be universal style. Contractor shall ensure provision of sprinkler guard at no additional cost. All pendent sprinkler will be provided with rossette plate

-

-

-

... More
Concealed Sprinkler 680C (K=80)

1

-

-

... More
Upright / Pendent Sprinkler 680C (K=80)

45

-

-

... More
Side wall Sprinkler 680C (K=80)

1

-

-

... More
Supply, installation, testing & commissioning of UL listed/FM approved Sprinkler SS braided Flexible Joint of 25mm diameter, consisting of - Flexible Tube (SS 304), S.S. Slip nut, Isolated Ring & O Ring - for Sprinklers Drop, which shall include necessary supports with a maximum working pressure of 14kgf/cm2 and temperature rating of 225oF. The length of Flexible Sprinklers Pipe shall be:

-

-

-

... More
1000mm

5

-

-

... More
1200mm

5

-

-

... More
1500mm

5

-

-

... More
Providing, fixing, testing & commissioning of C.I Butterfly valve conforming to IS : 13095 with flanges/grooved fittings, nuts, bolts and washers complete for following sizes :- [PN 10 rating kg/cm2 pressure rating)] of 80 mm dia

2

-

-

... More
Providing & fixing cast iron single acting air valve with screwed inlet 25 mm dia including Ball valve and all fitting & accessories.

1

-

-

... More
Providing & fixing water flow detectors / switches (Vane type) for sprinkler system, shall have sensitivity in the range of 4 to 10 US gallon per minute and static pressure rating of 450 PSI including accessories, junction box, suitable for indoor / outdoor mounting. The detector shall respond to water flow in the specified direction after a preset time delay that is field adjustable, complete as required suitable for fixing on fire pipe including connection for wiring. - on 65 to 100 mm dia line

2

-

-

... More
Providing ,fixing , inspecting ,testing of 50 mm drain Size & 15 mm (5.6 K) Testing orifice drain assembly for installation on sprinkler system, in brass body consisting of steel singler lever ball valve for multiple test and drain functions, inculding inlet connection of specified size , sight glass , connections to the main header and line drain complete as per requirement . Product shall suitable for min.10 Kg/cm2 working pressure.

2

-

-

... More
Providing and fixing M.S. structural work fabricated from standard sections, (MS rounds, angles, channels etc.) including cutting to size, drilling, welding, including cost of fasteners, clamps in RCC structural members as directed, including two or more coats of synthetic paint over one coat of primer after surface preparation including cutting and making good walls (Structural other than pipe support).

200

-

-

... More
HAND APPLIANCES

-

-

-

... More
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body,squeeze lever discharge valve fitted with internal discharge tube, 30cms long ISI marked high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge.

-

-

-

... More
Capacity 4.5kg. I.S.I. Marked.

4

-

-

... More
Capacity 9.0 Kg ISI Marked.

5

-

-

... More
Providing and fixing ABC stored pressure dry chemical powder (monoammonium phosphate) Fire Extinguisher IS : 13849 latest revision manufacturer and of CRCA sheet in welded construction, finish with epoxy polyster powder coated complete with brass forged ball valve, gun metal cap and nozzel, including initial filled and wall suspension bracket (suitable for fighting in class 'A', B & 'C' that is wood, textile, flammable liquid, electric and gases - Capacity 6 kg

8

-

-

... More
Providing and fixing mechanical foam type (ISI marked) fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cm long high pressure discharge hose, discharge nozzle suspension bracket ISI marked as per IS 933 finished externally with red enamel paint and fixed to wall with brackets complete with internal charger.50 litres capacity (trolly mounted) (IS : 13386)

1

-

-

... More
Providing and fixing carbon-di-oxide fire extingushers trolley mounted with all accessories internal discharge tube, high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.: Capacity 22.5 kg.

1

-

-

... More
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter "FIRE" in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets).

1

-

-

... More
Supply, installation, testing and commissioning of fire exit signage of photo luminescent on aluminium sheet of 1.0 mm (± 10%) containing lumigen-III as base chemical, covered with U/V stabilized coating size 450 x 200.

-

-

-

... More
Escape signs

323

-

-

... More
Fire signs

323

-

-

... More
General signs

323

-

-

... More
Supply and installation of 48 mm thick steel door shutter of 60 min fire rated confirming to BS-476, Part-22 and IS:3614part-II; abricated with 2 Nos. of 1mm thick galvanisedsteel sheet Size 1200 X 2380 MM S/L Sq. mtrs 8.568 with 202 grade SS ball bearing hinges (100x75x3 mm ) Assa Abloy, Fire rated door closer (standard arm) Assa Abloy, 60 min fire rated cleared wired glass (150X750X/7.3 MM), 202 grade SS back to backdoor handle (250 mm) Assa Abloy, Dead lock with 70 mm cylender Assa abloy complete in all respect to the satisfaction of Engiineer In-charge.sandwitching honeycombmaterial in between. Door frame are manufactured with 1.25 mm thick galvanised steel sheet pressed to formdouble rivet profileof size 143x60 mm. The frame and shutterare finished with powder coated.

5.5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.