Himachal Pradesh Agriculture Development Society Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Himachal Pradesh Agriculture Development Society Tender

Works
Civil And Construction
Irrigation Work
Eprocure
Opening Date29 Nov 2024
Closing Date9 Dec 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Boulder filling dry hand packed tightly as in wire crate apron bund(wire crate to be measured seprately) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

10.5

-

-

... More
Supplying and filling in plinth with sand under floors,including watering,ramming,consolidating and dressing complete in all respect as per entire satisfaction of engineer in charge

1.02

-

-

... More
Boulder/stone filling behind retaining walls complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

2.03

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work for :

-

-

-

... More
Foundations, footings, bases for columns, mass concrete complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

179.63

-

-

... More
Circular walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.

72.84

-

-

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.

18.56

-

-

... More
Suspended floors, roofs, landings, balconies and access platform complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

14.42

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.

2.03

-

-

... More
Edges of slabs and breaks in floors and walls complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

20.44

-

-

... More
Providing Mild steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

2195.47

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

857.99

-

-

... More
Providing and laying in position cement concrete 1:4:8 (1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of centering and shuttering complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

6.24

-

-

... More
Providing and laying in position cement concrete 1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of centering and shuttering complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

46.28

-

-

... More
Providing and laying in position cement concrete 1:2:4 (1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of centering and shuttering complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

-

-

-

... More
Foundation & plinth excluding the cost of centering, shuttering & reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

0.18

-

-

... More
Providing and laying in position reinforced cement concrete 1:1:2 ( 1cement : 1 sand : 2 graded stone aggregate 20 mm nominal size) and curing complete to the entire satisfaction of Engineer-in Charge

-

-

-

... More
In foundation,plinth, beams, suspended floors, roofs having slope landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto all level, excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

3.66

-

-

... More
In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto all level, excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

7.46

-

-

... More
Providing and laying in position reinforced cement concrete 1:1.5:3 (1cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size) and curing complete to the entire satisfaction of Engineer-in Charge

-

-

-

... More
Foundation & plinth excluding the cost of centering, shuttering & reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

25.83

-

-

... More
In beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above or below plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-charge.

2.89

-

-

... More
In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering,finishing and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-charge.

3.04

-

-

... More
Random Rubble Masonary with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12( 1 Cement:6 coarse sand:12 graded stone aggregate ,20mm nominal Size) upto plinth level complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

7.58

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in Charge

7.35

-

-

... More
Half Burnt brick with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in Charge

1.81

-

-

... More
Providing & laying Damp Proof Course 40mm thick with cement concrete 1:2:4 (1 cement:2sand:4 graded stone aggregate 10 mm nominal size) & curing complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in Charge.

2.69

-

-

... More
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in Charge

2.69

-

-

... More
Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

6.12

-

-

... More
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35 x 35 x 5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

42.12

-

-

... More
Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden/ steel frames of windows and clerestory windows (M.S. grill) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

29.84

-

-

... More
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

14

-

-

... More
Providing and fixing ISI marked oxidised M.S. sliding door bolts (250 x 16 mm) with nuts and screws etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

1

-

-

... More
Providing and fixing ISI marked oxidised M.S. tower bolt (250 x 10 mm) black finish, (Barrel type) with necessary screws etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

6

-

-

... More
Providing and fixing ISI marked oxidised M.S. handles (125 mm) conforming to IS:4992 with necessary screws etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

14

-

-

... More
6 mm cement plaster on the rough side of brick wall in cement mortar 1:3 (1 cement: 3 Coarse sand) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

13.52

-

-

... More
15 mm cement plaster on the rough side of brick wall in cement mortar 1:4 (1 cement: 4 Coarse sand) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

67.36

-

-

... More
Providing under layer for plinth protection 50mm thick of cement concrete1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand

4.52

-

-

... More
Finishing with epoxy paint (two or more coats) at all locations prepared on steel work and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

24.15

-

-

... More
White washing with lime to give an even shade New Work (three or more coats) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

43.4

-

-

... More
Finishing walls with water proofing cement paint of required shade: New Work (Two or more costs applied @ 3.84 kg/10sqm) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

37.48

-

-

... More
Providing and fixing ISI marked oxidised M.S. fan clamps 1 of 16mm dia M.S bar bent to shape with hooked ends in R.C.C slab during laying including painting the exposed portion of loop,all as per standard design complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

1

-

-

... More
Providing & Fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS 13592 Type A including jointing with seal ring confirming to IS 5382 leaving 10mm gap for thermal expansion single socketed pipes of 110 mm Dia U-PVC pipes complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

6.6

-

-

... More
Providing & Fixing on wall face unplasticised PVC moulded fitting/accessories for unplasticised Rigid PVC rain water pipes confirming to IS 13592 Type A including jointing with seal ring confirming to IS 5382 leaving 10mm gap for thermal expansion single pushfir coupler of 110 mm dia. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

3

-

-

... More
Providing & Fixing on wall face unplasticised PVC moulded fitting/accessories for unplasticised Rigid PVC rain water pipes confirming to IS 13592 Type A including jointing with seal ring confirming to IS 5382 leaving 10mm gap for thermal expansion bend 87.5° of 110 mm dia. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

2

-

-

... More
Providing & Fixing on wall face unplasticised PVC moulded fitting/accessories for unplasticised Rigid PVC rain water pipes by means of 50*50*50 mm hard wood plugs,screwed with M.S screws of required length,including cutting brick work and fixing in cement mortar 1:4 (1 Cement:4 coarse sand ) and making the good wall etc complete of 110mm Dia complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

6

-

-

... More
Providing & fixing manual chain pulley of 1 ton capacity complete with all accessories complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

1

-

-

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete in all respect to the entire satisfaction of Engineer-in-charge

9.28

-

-

... More
Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post,last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc.complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With GI barbed wire

145.35

-

-

... More
Providing & Laying, Jointing , Testing & Commisioning at site in trenches bevelled ended BIS Marked MSREW pipes 250 mm dia of various grade confirming to IS/ISO-3183-2012 L260 or X42 or equuivalent specifications latest with up to date amnendments of following dia having wall thickness and per Rmt weight as mentioned below & capable of withstanding required test pressure as per BIS code in random lengths of 6-7 mtr.The pipes end should be bevelled and suitable for butt welding including the cost of jointing with butt weld confirming to IS 816-1969 or latest as applicable with the ends with upto date amendments(leak proof) in three layers at site of work with welding rods of standard make and all allied accessories whatever required as per site requirement including carriage in all leads and lifts as directed by Engineer-in-charge.Pipe shall have Zinc coating inside & outside confirming to IS/ISO 4736-1986 or latest with upto date amendments &shall be engraved with code IS/ISO 3183-2012 or its equivalent.laying shall confirm to BIS 5822-1970 or latest with upto date amendments with provision of scour pipe after every km by providing Tee & Sluice valve etc. complete to the entire satisfaction of Engineer-in-charge.

4

-

-

... More
Providing and fixing CI Sluice valve 250 mm dia 10.2 kg/cm^2 kartar make(PN 1.0) i/c MS Flange of table as per IS 6392-1971 of 5WT of 121.50 Kg & Welding of MS Flanges in two layers in both side faces and & i/c carriage for suction pipe from sump well to pump in all respects within all lead and lift to the entire satisfaction of the Engineer-in-Charge.

1

-

-

... More
Providing and fixing CI Sluice valve 150 mm dia 10.2kg/cm^2 kartar make i/c MS Flange of table as per IS 6392-1971 of 5WT of 71.30 Kg & Welding of MS Flanges in two layers in both side faces and & i/c carriage in all respects within all lead and lift to the entire satisfaction of the Engineer-in-Charge.

2

-

-

... More
Providing and Fixing CI Non Return Valve 100 mm ø (PN-1.0) 10.2Kg/cm² Kartar make i/c MS Flange of Table-5 as per IS 6392-1971 of 5 WT of 49.00 Kg &Welding of MS Flanges in two layers on both faces and & i/c carriages in all respects within all leads & lifts to the entire satisfaction of the Engineer-in-Charge.

2

-

-

... More
Providing and Fixing CI Sluice Valve 100 for suction pipe from sump well to pump house mm ø (PN-1.0) 10.2Kg/cm² Kartar make i/c MS Flange of Table-5 as per IS 6392-1971 of 5 WT of 44.30 Kg &Welding of MS Flanges in two layers on both faces and & i/c carriages in all respects within all leads & lifts.

1

-

-

... More
Providing and Fixing CI Sluice Valve 80 mm ø (PN-1.0) 10.2 Kg/cm² Leader / Kartar / Kirloskar make i/c MS Flange of Table-5 as per IS 6392-1971 WT of 31.30 Kg & Welding of MS Flanges in two layers on both faces and & i/c carriages in all respects within all leads & lifts.complete to the entire satisfaction of Engineer-in-Charge

2

-

-

... More
Providing and Fixing CI Sluice Valve 65 mm ø (PN-1.0) 10.2 Kg/cm² Leader / Kartar / Kirloskar make i/c MS Flange of Table-5 as per IS 6392-1971 WT of 23.30 Kg & Welding of MS Flanges in two layers on both faces and & i/c carriages in all respects within all leads & lifts.complete to the entire satisfaction of Engineer-in-Charge

2

-

-

... More
Providing and fixing HDPE Air Release Valve of 25 mm dia with G.I Socket of 25 mm Dia. Tee & GI Nipple of 25 mm Dia. in Distribution System including Jointing & fitting complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

2

-

-

... More
Providing, laying, joiniting and testing in trenches (to level or grade) GMS tube(IS : 1239-2004) of 100 mm dia & medium class confirming to IS specification capale to withstand the required Hydraullic test pressure as per IS code inrandom length of 6m for scour pipe and overflow pipe complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in Charge. (EARTH WORK IN TRENCHES TO BE MEASURED PAID FOR SEPARATELY)

226

-

-

... More
Providing, laying, jointing, commissioning and testing in trenches (to level or grade) GMS tubes for scour pipe and overflow pipe confirming to IS : 1239 : 2004 of 150 mm dia, medium class with all necessary fittings conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. including flushing , cleaning and hydraulic testing of pipe complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.

20

-

-

... More
Providing circumferencial Butt welded joints by electrical arc welding to GMS tubes confirming to IS : 1239 : 2004 of 100 mm dia, welded in requisite numbers of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani Oerlikon (Adore) - Citojet / ESAB make conforming to IS 814-1991, at site of work complete in all respect including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.

34

-

-

... More
Providing, welding and fixing of M.S. flanges at suitable locations, conforming to table 5, 100 mm dia as per IS:6392-1971 (latest with upto date amendments) and welding of MS Flanges with G.I. Pipes/ MSERW pipes in two layers on both faces to make the joint leak proof (the cost of providing and laying of G.I.Pipes/MSERW Pipes to be measured and paid for separately). The welding of flanges should conform to IS 816-1969 with electrode as per IS : 814-1991 and required number of nuts & bolts conforming to IS: 1364. The thickness of gasket not less than 3.00mm conforming to IS : 2712-1998. The work shall be done as per entire satisfaction of Engineer-in-Charge within all leads and lifts.

3

-

-

... More
Printing new letters and figures of any shade with synthetic enamel black or any other approved colour to give even shade as per drawing and technical specification clause 1701 in eglish and roman,hypen,commas and like not toi be measured and paid for complete with all leteers and to the entire satisfaction of Engineer-in-charge

2076

-

-

... More
Supply, Erection, Comissioning & testing of Open Well Horizontal Submersible pumping set of KSB /BS/Johnstion/oswal/Crompton/Kirloskar/Calama make comprising to latest relevant BIS Code. The pump should be fitted with bronze impeller of suitable alloys as per IS 8034-1979 latest suitable for Clear water having greased packed bearings and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) of required HP, RPM 2900 of reputed make conforming to BIS 9238-1979 latest with upto date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The rate of pump set should include all items containing sr. no. 54.01 to 54.80, water level guards, erection clamps , cable clips and depth gauge etc. and suitable for operation on data given below complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge:-

1

-

-

... More
SITE CONDITIONS:-

-

-

-

... More
Location of site:-Trauntra

-

-

-

... More
The altitude of place in which the motor is intended to work in ordinary service

-

-

-

... More
Humidity:- Humid during rainy season

-

-

-

... More
Nature of atmosphere:-Normal

-

-

-

... More
Detail of quality of water:- Clear water

-

-

-

... More
Water free from sand or not:-Free from sand

-

-

-

... More
Water corrosive or not:-Not corrosive

-

-

-

... More
Turbidity:-Less than 50 ppm

-

-

-

... More
Any other information if required.

-

-

-

... More
OPERATING CONDITIONS

-

-

-

... More
Type of current:AC. Three phase

-

-

-

... More
Operating frequency:50 Hz.

-

-

-

... More
Rated voltage-400(+/-) 10% volts.

-

-

-

... More
System of earthing if any to be adopted-Double loop earthing

-

-

-

... More
Speed of revolution-To be quoted by tenderer .

-

-

-

... More
Direction of rotation-To be quoted by tenderer .

-

-

-

... More
No. of working hours per day:-20.00 hours

-

-

-

... More
The maximum temperature of cooling air and water in the place in which the pump set is intended to work in ordinary service:-Temperature of place to be specified 20°C to 42°C.

-

-

-

... More
MOTOR-

-

-

-

... More
Ref. to BIS code:-BIS 9283-1979 with upto date amendments

-

-

-

... More
Type of enclosure of motor.-As per BIS-4691-1985 (Latest)

-

-

-

... More
Type of duty :-Continuous

-

-

-

... More
Mechanical output in KW-Suitable for driving submersible pumps required for duties specified against pumps. To avoid overloading of motor a margin of about 15-20% may be kept in the rated output to prime Mover.

-

-

-

... More
Class of insulation -Class –B

-

-

-

... More
Max. Permissible temp. Rise of motor reqd. if different from that given in 8 (viii) above.--To be specified by the tenderer.

-

-

-

... More
Particulars of test reqd. & where they are to be conducted.-AS per terms and conditions attached.

-

-

-

... More
Particulars as to whether voltage limiting device will be employed :Oil immersed star delta starter to be installed between bus bar and motor. Shunt capacitor is also proposed to be installed for improving the power factor at site..-Note:- Star delta starter upto 37.5 Kw.

-

-

-

... More
Type of motor:As per BIS 9283-1979 or latest.

-

-

-

... More
Details of shaft extension required

-

-

-

... More
Break way torque in terms of rated load torque and the corresponding break-way starting current which may be taken from the supply with the starting apparatus in circuit.-To work the pump offered :Break way torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.

-

-

-

... More
Nature of load and any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelerated and No. of starts during a specified period. -To work the pump offered

-

-

-

... More
Where possible fault capacity of the system to which the motor is connected:-The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations.

-

-

-

-

-

-

... More
Nos. of pumps required.- 1 No.

-

-

-

... More
Spare parts required.-For two years normal maintenance as recommended by manufacturer.

-

-

-

... More
Type of drive:Electric induction motor.

-

-

-

... More
Optional fittings required

-

-

-

... More
Pump Operating conditions

-

-

-

... More
Capacity :-6.68 lps for one pump

-

-

-

... More
Total head in meters:-33.11 mtrs

-

-

-

... More
Static head :-29.40 mtrs

-

-

-

... More
Minimum depth of water (mtrs)

-

-

-

... More
Variation in water level (mtrs)

-

-

-

... More
Ground level to Max. water level (H.F.L) (mtrs)

-

-

-

... More
Ground level to delivery point (mtrs)

-

-

-

... More
Pressure in the suction tank. (mtrs)

-

-

-

... More
Pressure in the delivery tank Rising main-1 (mtrs)

-

-

-

... More
Length of rising main:-60.00 Rmt

-

-

-

... More
Dia of rising main :-100 mm

-

-

-

... More
Turbidity of water 50ppm

-

-

-

... More
Drive type (Electric Driven)

-

-

-

... More
Limits of total head in which the pump is required to operate (-)15% to (10%) of total head

-

-

-

... More
Suction/Delivery size of pump To be specified by the tenderer.

-

-

-

... More
Efficiency of pump at

-

-

-

... More
a)     Duty head

-

-

-

... More
b)     (+) 10% head.

-

-

-

... More
c)      (-) 15% head. To be specified by the tenderer (manufacturers certificate to be appended)

-

-

-

... More
Material of construction to be specified by tenderer

-

-

-

... More
Providing Direct on line of MEI/Kilburn/make confriming to BIS 8544-1979 latest with all upto date amendments for Squirrel Cage/ Slipping Motor mounted on Pannel with Magnetic type overload release and Dashpot, Time lag, Under Voltage release of suitable capacity, with or without initial oil filling of suitable capacity. 1 No.

-

-

-

... More
Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel board shall be subject to approval of Engineer-in-Charge. 1 No.

-

-

-

... More
Providing & Fixing Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of suitable capacity for above motor with selector switches conforming to BIS-1248-1983 latest with upto date amendments. 1 No.

-

-

-

... More
Providing & Fixing Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of 0-500 Volts range for above motor with selector switches conforming to BIS-1248-1983 latest with upto date amendments. 1 No.

-

-

-

... More
ICTP switches with HRC fuses of Havells/L&T/standard /cromption make for required motor of suitable capacity and conforming to BIS: 4064-1978 latest with upto date amendments. 1 No.

-

-

-

... More
Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutral conforming to BIS: 8084 –1976 and 11353-1985 read with 5578-1985 all latest with upto date amendmentsof suitable rating. 1 Set

-

-

-

... More
MCB of suitable capacity of Havells/standard/MDS/Jyoti/Kilburn make to feed motors offered by the tenderer conforming to BIS: 2516-1985 latest with upto date amendments with neutral linked under voltage release. 1 no.

-

-

-

... More
3 phase indicator lamps complete with toggle switches for individual motors conforming ti BIS 3452 part I & II latest with up to date amendments of 15 watts. 1 No.

-

-

-

... More
50 mm dial Hour run meter of CEE/NEE make of suitable range as per relevant BIS specifications. 1 No.

-

-

-

... More
Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments Baja/L&T/Asian/cromption make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to BIS –4064-1978 or latest with HRC fuses (range to be specified by the tendrerer). 1 No.

-

-

-

... More
Providing and Fixing CI Sluice Valve PN-1.0 10.2Kg/cm² Kirloskar/Leader make i/c double flanged Sluice Valve Having Size one dia. Higher than Pump & capable of withstanding nominal seat pressure of 10.20 Kg/cm2 as per IS Code 14846:2000. 1 No.

-

-

-

... More
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments siemen/IEC/ GICO/ Finolex/ closter/ICC make form meter of HPSEB- to MCB and form MCB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. 60 Rmt.

-

-

-

... More
Supply Side: Suitable Size

-

-

-

... More
Motor Side: Suitable Size

-

-

-

... More
Providing and Fixing Kirloskar/Leader make i/c double flanged (Swing Check Type) Reflux Valve Having Bypass Arrangement and Having Size one dia. Higher than Pump to delivery of Pump & capable of withstanding nominal seat pressure of 10.20 Kg/cm2 as per IS Code 5312-1984 (P-I) 1 No.

-

-

-

... More
Supply of PVC joint less flat water proof cable as per BIS: 694-1990 latest with upto date amendments suitable for the pump sets offered from MCB to motor including all other electrical equipment/accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced by tender. 60 Rmt.

-

-

-

... More
Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of required capacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and other electrical equipment’s. 1 Nos.

-

-

-

... More
Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to BIS: 3624-1987 latest with upto date amendments. 1 No.

-

-

-

... More
Providing and laying delivery pipe 80 mm dia. GMS Tubes (Medium Class) (IS:1239 - 2004) jointed with MS flanges of table-5 as per IS: 6392-1971 (upto a length of 20 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses as per layout drawings approved by Engineer-in-Charge.(From Pump to Common header) 1 Rmt.

-

-

-

... More
Installation charges on all equipment including cost of tees, Flow meter, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge. 1 Job

-

-

-

... More
Providing & Fixing, Erection of electricity system in Pump House (One Fan, One C.F.L outside & Inside , One 5 Amp Socket Inner side & Outer Side of Pump House, One 16 Amp Socket inner Side of Pump house. 1 Job

-

-

-

... More
Providing and fixing M-POWER MODULE, L&T make for mobile controller Vide Cat no.GSM 03010000 of reputed make confirming to standard with upto date with supply 160-500 v . AC- 50 hz .single phase /three Phase wire including cabling computed to delivery resultscomplete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

2

-

-

... More
Providing and fixing capacitor -15 kvr with mobile set including sims with message pack complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

2

-

-

... More
Providing and fixing automatic pannel board MU-G40 of L&T make for 35HP Submersible Motors make manufactured by parental company comprising MNX contacts and MN relays, overload and single facing protection confirming to IS-13947-4 IEC -60947-4 alongwith testing certificate including pushing button autostart , auto stop and restart facility, ICTP switches and all other electrical accessories which required for the job single phase preventor, 3- phase indicator, time ,relay selector Cabiling to delivery results complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.

1

-

-

... More
Supply,installation,testing & commissioning of Centrifugal horizontal spindle,horizontal split casing/end suctions(back full out arrangement) single/multistage centrifugal pump or combination of pump in series of recommended make such as Mather and Platt/KSB/Kirloskar/B&S/Becon as per IS-1520-1980 (latest with up to date amendements) read with IS:9137-1978 or latest edition suitable for lifting clear water for under mentioned charcteristics with bronze impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a MS/Cast steel base plate (base plate to be from the manufacturers of the pumping unit only) to ring/squirrel cage screen protected drip proof induction motors of standard make such as Kirloskar/Crompton/NGEF suitalbe for operation on 400(+/-) 10% volts,50 cycles/second,3 phase AC electric supply.The power required by the pump in the operation range of (+)10% and(-) 15% of the duty point head.The motor should be as per IS:325-1978 with up to date amendments read with IS:900-1972.It should include flow meter,cost of bearing nuts,bolts and pointing etc. and should meet the following requirement.The pumping set should include water level guards i/c cable,erection clamps,cable clips and depth gauge etc.and any other item/fitting required as per site conditions and suitable for operation of pumping machinery on data mentioned below from The pump set should include all items containing item no 58.01 to 59.33 complete to the entire satisfaction of engineer-in-charge:-

1

-

-

... More
Specification

-

-

-

... More
Pumps:

-

-

-

-

-

-

-

-

-

... More
Nos. Of stages

-

-

-

... More
Material manufacturers certificate to be appended performances

-

-

-

... More
Head(H)

-

-

-

... More
Discharge (Q)

-

-

-

... More
BHP absorbed

-

-

-

... More
Efficiency(n)

-

-

-

... More
NPSH(K)

-

-

-

... More
MOTOR (Specification)-1 Nos.

-

-

-

-

-

-

-

-

-

... More
Motor rating(Kw)

-

-

-

... More
Speed

-

-

-

... More
Insulation

-

-

-

... More
Coupling-1 Nos.

-

-

-

... More
Base plate-1 Nos.

-

-

-

... More
Discharge (Q)-6.07 LPS

-

-

-

... More
Total dynamic head-47.67 mtrs.

-

-

-

... More
LWL (h)-623.79 mtrs

-

-

-

... More
Shaft level-623.60 mtrs

-

-

-

... More
Level at discharge point-666.6 mtrs.

-

-

-

... More
Suction lift: -0.19 mtrs

-

-

-

... More
Residual head: 1 mtrs

-

-

-

... More
Static head:43.00 mtrs.

-

-

-

... More
Rising main

-

-

-

... More
Length: 160 mtr.

-

-

-

... More
Dia:100 mm

-

-

-

... More
Pumping Hours: 20 hours

-

-

-

... More
Providing ICTP main switch with HRC fuses/side handled operated change over switch of L&T/Crompton/Standard/Havells make for required motor and having capacity 30% extra of the operational rating of motors as per IS:4064 (Part-II)-1978 latest with upto date amendments.-1 no.

-

-

-

... More
ICTP Switches:-

-

-

-

-

-

-

-

-

-

... More
Capacity:Suitable Capacity

-

-

-

... More
Providing & fixing of M.S. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah) switch board comparising and capable of mounting the following accessories and with all internal electric connections,duly painted.The drawing of panel board shall be subject to approval of engineer in charge. 1 No.

-

-

-

... More
Panel/Switch Board:

-

-

-

... More
Drawing

-

-

-

... More
Layout plan

-

-

-

... More
Providing & fixing of MCB of suitable capacity of Havells/Standard/MDS/Jyoti/Kilburn make on incoming feeder motors with or without initial oil filling as the case may be offered by the tenderer conforming to IS:2516 (Part-II)-1985 latest with upto date amendments with neutral linked under voltages release .1Nos.

-

-

-

... More
M.C.B.

-

-

-

-

-

-

-

-

-

... More
Range:Suitable Capacity

-

-

-

... More
Providing & fixing ELCB of havells/standard make as per IS:2516 (Part-II)-1985 with up to date ammendments and of suitable range which should have control box,operating handle & trip/reset bush button on/off of indicators,reindicating off spring condition of the circuit breaker for over current protection.The circuit should be equiped with magnet thermal release with metallic tape CTS.It should also be fitted with earth fault for tripping of breaker on occurance of earth fault.-1 No.

-

-

-

... More
E.L.C.B.

-

-

-

-

-

-

-

-

-

... More
Range:Suitable Capacity

-

-

-

... More
Providing & fixing Voltage monitor relay 3 phase of AE/L&T/Rishab make with all protection and usual indicator and electric siren against single phasing ,low voltage,high voltage,reverse phasing,overloading and phase voltage difference conforming to IS-1248 (Part-II)-1983 latest with upto date amendments.1 No.

-

-

-

... More
Voltage relay monitor

-

-

-

-

-

-

-

-

-

... More
Range:380-440 Volts

-

-

-

... More
Providing & fixing Voltmeter AC supply,125 mm square type auto electric AE/L&T Rishab make of 0-500 Volts range for above motor with selector switches confirming to IS-1248(Part-II)-1983 latest with upto date amendments.1 No.

-

-

-

... More
Voltmeter

-

-

-

-

-

-

-

-

-

... More
Range:0-500 V

-

-

-

... More
Providing & fixing Power Factor Meter of AE/L&T Rishab make as per IS:1248 (Part-V)-1983 with upto date amendments and of suitable rating. 1 No.

-

-

-

... More
Power factor meter

-

-

-

-

-

-

-

-

-

... More
Providing & fixing Frequency Meter of AE/L&T Rishab make as per IS:1248 (Part-V)-1983 with upto date amendments and of suitable rating..1 No.

-

-

-

... More
Frequency meter

-

-

-

-

-

-

-

-

-

... More
Range:Suitable rating

-

-

-

... More
Providing & fixing bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with BIS 5578-1985 all latest with upto date amendments of suitable rating..1 Set

-

-

-

... More
Bus Bar Chamber

-

-

-

-

-

-

-

-

-

... More
Range:Suitable rating

-

-

-

... More
Providing & fixing 3 phase indicator lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II with up to date amendments.1 Set

-

-

-

... More
Three phase indicator

-

-

-

-

-

-

-

-

-

... More
Range:Suitable rating

-

-

-

... More
Providing & fixing of Ammeter AC supply,125 mm square type auto electric of AE/L&T Rishab make of suitable capacity for above motor with selector switches confirming to IS-1248 (Part-II)-1983 latest with upto date amendments.1 No.

-

-

-

... More
Ammeter

-

-

-

-

-

-

-

-

-

... More
Range:Suitable rating

-

-

-

... More
Providing & fixing of Capacitor/shunt capacitor of Crompton/L&T/Asian make as per IS:2834-1968 with upto date amendments,to raise the power factor at site to .95 for direct connections to induction motor individually of required KVA Rating according to H.P of motor offered including cables as per relevant ISI Code(of Siemens/Gloctor/IEC make) from bus bar chamber to capacitor as per IS:4064-1978 with upto date amendments 1 No.

-

-

-

... More
Capacitor

-

-

-

-

-

-

-

-

-

... More
Suitable range

-

-

-

... More
Providing & Fixing of Suitable DOL/Star Delta Starter of L&T/Siemens/Crompton make as per IS 8544 (Part-I)-1967 with upto date amendments for Squirrel cage/Slipring motor mounted on panel board with magnetic type over load release and dashpot ,time lag,under voltage release,with or without intial oil filing as the case may be with single phase preventor as per IS:1248(P-V)1983 with upto date amendments 1 No.

-

-

-

... More
Starter

-

-

-

-

-

-

-

-

-

... More
Single Phase Preventor

-

-

-

-

-

-

-

-

-

... More
Providing & fixing of 50mm dial hour run meter of CEE/NEE/reputed make of four digit capacity confirming to BIS 722(latest Edition) 1 No.

-

-

-

... More
Hour Run Meter

-

-

-

-

-

-

-

-

-

... More
Range:-Suitable rating

-

-

-

... More
Providing and laying suitable size copper PVC insulated armoured power cable of suitable size and capacity to motors and other electrical equipments conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments siemen/IEC/ GICO/ Finolex/ closter/ICC make form meter of HPSEB- to MCB and form MCB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. 12 Rmt.

-

-

-

... More
Supply Side: Suitable Size

-

-

-

... More
Motor Side: Suitable Size

-

-

-

... More
Providing & fixing double lopp earthing and G.I plate 600mm*600mm*3mm thick electrode complete with material such as thimbles nuts and bolts,charcoal and common salt,25mm*6mm G.I strips &G.I wire as per IS 3043:1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect 1 Job

-

-

-

... More
Providing & Fixing of antivibration pads confirming to BIS 6337-1971 or latest with up to date amendments. 1 Job

-

-

-

... More
Providing & Fixing Double flanged cast iron/ cast steel sluice valve of Leader/Kirloskar/kartar of required dia as per the size of delivery line withstanding nominal seat pressure of P.N-1.0(10.2 Kg/Cm^2) as per IS 780-1964(Part-I) with MS Flange of Table 5 as per IS 6392-1971 & Welding of MS Flanges in two layers on both faces complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-charge 2 Nos.

-

-

-

... More
Sluice valve(80 mm Dia)

-

-

-

-

-

-

... More
Class PN 1.0

-

-

-

... More
Seat Pressure 10.20 Kg/cm^2

-

-

-

... More
Material C.I

-

-

-

... More
Providing & Fixing double flanged cast iron/cast iron steel Non Return valve of Leader/Kirloskar/Kartar makeo f required dia as per the siaze of delivery line withstanding nominal seat pressure of P.N-1.0 (10.2 Kg/cm^2) as per IS 5312-1984 with M.S flange of table 5 as per IS:6392-1971 & Welding of MS Flanges in two layers on both faces complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge 1 No.

-

-

-

... More
Non Return Valve(80 mm Dia)

-

-

-

-

-

-

... More
Class PN 1.0

-

-

-

... More
Seat Pressure 10.20 Kg/cm^2

-

-

-

... More
Material C.I

-

-

-

... More
Providing & fixing of 100mm dia circular dial Pressure gauge of Feibig/Bourden make 0-16 kg/cm^2) range of feibig make all accessories such as stop cock,copper tubing etc,confirming to BIS 3624-1987 latest with upto date amendments 1 No.

-

-

-

... More
Pressure gauge

-

-

-

-

-

-

... More
Range:-0-52 kg/cm^2

-

-

-

... More
Installation charges on all equipment including cost of tees, Flow meter(2 Nos. at pump house and MDT), bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge. 1 Job.

-

-

-

... More
Providing & Fixing double flanges G.M.S piuping work layout to be approved by the Engineer-in-charge for suction and delivery pipes suitable to pumps offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/increases with companion flanges matching with the relevant specifications of the accssories indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3 mm thickness as per IS 2712-1979 and required no of nuts and bolts as per IS 1364-1983,tees,bends,tapers & any other fitting requires as per site conditions .The pipes shall be as per relevant IS Code 1239:2004 and to withstand 1.5 times total head stipulated under item No.Ist G.M.S Tube Confirming to IS 1239-1990(Part-I) (Medium Class) flanges with M.S Flanges of Table-5

-

-

-

... More
Suction Pipe

-

-

-

-

-

-

-

-

-

... More
Thickness

-

-

-

... More
Pressure rating

-

-

-

... More
The of varoius component under:-

-

-

-

... More
Suction Pipe 100 mm dia

6

-

-

... More
Delivery pipe 80 mm dia

6

-

-

... More
125 mm.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.