Department Of Tourism And Civil Aviation Tender

... More
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Department Of Tourism And Civil Aviation Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date13 Jan 2025
Closing DateCancelled
Tender Amount₹ 7,07,45,327 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Filling available excavated earth in all kind of soils ,in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, including carriage of material in all leads and lifts as per the direction of Engineer-in- Charge.

698.08

-

-

... More
Excavating,spplying,stacking and filling of local earth ( including royalty)by meachanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20cm in foundation trenches,plinth,sides of foundation etc.complete for all lift. including carriage of material in all leads and lifts as per the direction of Engineer-in- Charge.

6472

-

-

... More
Preparation and consolidation of sub grado wilh power road roller of 8 to 12 tonne capacity after excavating earth to an average ol 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and ra-rolling tho sub grade and disposal of surplus earth with lead upto 50 metres.including carriage of material in all leads and lifts as per the direction of Engineer-in- Charge.

2930

-

-

... More
Extra for compaction of earth work in embankment under optimum moislure conditions to give at least 957o of the maximum dry density (proctor density).including carriage of material in all leads and lifts as per the direction of Engineer-in- Charge.

440

-

-

... More
Supplying and filling in plinth with river sand under floors, including watering, ramming, consolidating and dressing complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

73

-

-

... More
Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

7

-

-

... More
Diluting and injecting chemical emulsion for post construction anti termite treatment Treatment of soil under floors and apron using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the Plinth level :With Chlorpyriphos/Lindane E.C. 20% with 1% concentration including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

409

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth level. 1:4:8 ( 1 cement : 4 coarse sand zone II derived from natural sources,8 graded stone aggregate 40mm nominal size derived from natural sources including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

145

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:3:6 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

313

-

-

... More
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

4.28

-

-

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

111

-

-

... More
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III):4 graded stone aggregate 12.5mm nominal size) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

74

-

-

... More
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification work in doses by weight of cement as per manufacturer's specification.including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

288

-

-

... More
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7Per Kilogramme per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

74

-

-

... More
Extra tor addition of synthetic Polyester triangular fibte of length 12mm. Bffectivo diameter '10-40 microns and specific gravity of 1.34 to 1.40 in cement oncrele/RCC /Flooring/water retaining structures by using 125gms of synthetic Polyester triangular fibre for 50 Per Kilogramme cemont used including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

184.2

-

-

... More
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 Per Kilogramme/Per cubic Metre. Excess/less cement used as per design mix is payable/recoverable separately) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

-

-

-

... More
All works upto Plinth level concrete of M25 grade with minimum cement content of 330 Per Kilogramme/Per cubic Metre

365.53

-

-

... More
All works above plinth level upto floor V level concrete of M25 grade with minimum cement content of 330 Per Kilogramme/Per cubic Metre

265.45

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete .Thermo-Mechanically Treated bars of grade Fe-500D or more..(TATA/Sail/Jindal Make or equivalent ) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

86807.2

-

-

... More
Providing from work with steel plates 3.15 mm (three decimal fifteen millimeter ) thick welded with angle iron in frame 30X30X5 mm (thirty into thirty into five millimeters )so as to give a fair finish including centering , shuttering ,strutting and propping etc. with wooden battens and ballies for all heights of propping and centering below supporting floor to ceiling & removal of same for in-situ reinforced concrete and plain concrete work including carriage of material in all leads and lifts of materials as per direction of Engineer -in -charge.

-

-

-

... More
Foundation, footing, bases of columns etc. for mass concrete

1336

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

949

-

-

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

333.7

-

-

... More
Suspended floors,roof,landing,balconies and access platform

65.29

-

-

... More
Walls (any thickness) including attached pilasters,butteresses,plinth and string courses etc.

1271

-

-

... More
Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like

8

-

-

... More
Weather shade, Chajjas, corbels etc., including edges

32

-

-

... More
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) including carriage of material in all leads and lifts of materials as per direction of Engineer -in -charge.

2.29

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. (2nd class)

131

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to all floor level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. (2nd class)

90

-

-

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to all floor level. Cement mortar 1:4 (1 cement :4 coarse sand) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. (2nd class)

353

-

-

... More
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

353

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Granite of any colour and shade

-

-

-

... More
Area of slab upto 0.50 Per Square Metre

90

-

-

... More
Area of slab over 0.50 sum.

32

-

-

... More
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

-

-

-

... More
300x10 mm

2

-

-

... More
Providing and fixing aluminium handle ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

-

-

-

... More
125 mm

6

-

-

... More
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete: including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

-

-

-

... More
a) Twin rubber stopper

2

-

-

... More
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

2

-

-

... More
Providing and fixing 25mm wooden planking,tongued and grooved in flooring,including fixing with iron screws complete with second class teak wood including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

8

-

-

... More
Providing & fixing stone slab with table rubbed,edges rounded and polished of size 75x50 cm deep and 1.8cm thick fixed on parapet top by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size ) as per direction of Engineer in charge and finished smooth.including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

-

-

-

... More
Granite stone of approved make.

15

-

-

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Granite work

24

-

-

... More
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

24

-

-

... More
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

12

-

-

... More
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

-

-

-

... More
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

73

-

-

... More
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete.including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

-

-

-

... More
300x16 mm

2

-

-

... More
Providing and fixing Kota stone slab flooring over 20mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab cement mortor 1:4 ( 1 cement : 4 coarse sand ) 25mm thick including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

44.31

-

-

... More
Providing and fixing kota stone slabs 20mm thick in risers of steps,skirting,dado and pillars laid on 12mm (average ) thick cement mortor 1:3 ( 1 cement 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs,including rubbing and polishing complete. for skirting including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

2

-

-

... More
Providing and fixing Ist quality ceramic glazed wall tiles size 300x300 conforming to IS: 15622 , of approved make NITCO/KAJARIA or equivalent , in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3Per Kilogramme per Per Square Metre, including pointing in white cement mixed with pigment of matching shade complete.including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

363.54

-

-

... More
Providing and laying vitrified floor tiles Size 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make NITCO/KAJARIA or equivalent , in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3Per Kilogramme/Per Square Metre including grouting the joints with white cement and matching pigments etc., complete. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

236

-

-

... More
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make NITCO/KAJARIA or equivalent, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3Per Kilogramme/ Per Square Metre including grouting the joints with white cement and matching pigments etc., complete. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

44

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacture in all colours and shede in skirting,riser of steps,laid with cement based high polymer modified quick set tile adhesive ( water based )confirming to IS 15477 in average 6mm thickness including grouting of joints ( payment for grouting of joints to be made separately). Size of Tile 600x600 mm

31

-

-

... More
Providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manifacture ) of 1st quality confirming to IS : 15622 of approved make NITCO/KAJARIA or equivalent in colours such as white,Ivory,Grey,Fume Red Brown,laid on 20mm thick cement mortor 1:4 ( 1 cement : 4 coarse sand )jointing with grey cement slurry @ 3.3 Per Kilogramme/Per Square Metre including pointing the joints with white cement and matching pigment etc.complete. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

26

-

-

... More
62mm thick cement concrete flooring with concrete hardner topping,under layer 50mm thick cement concrete 1:2:4 ( 1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size ) and top layer 12mm thick cement hardner consisting of mix 1:2 ( 1 cement hardner mix : 2 graded stone aggregate.6mm nominal size ) by volume,hardening compound mixed @ 2 lit per 50 Per Kilogramme of cement or as per manufacture's specification.This includes cost of cement slurry,but excluding the cost of nosing of steps etc.complete. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

151

-

-

... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ Per Square Metre, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

-

-

-

... More
GI Metal ceiling Lay in perforated Tegular edge global white color tiles of sie 595x595mm

403

-

-

... More
Providing & laying Gypsum panel partition 100mm thick with water proof gypsum panels of size 666x500x100mm made of calcite phosphor gypsum fixed with tongue and groove edges and jointed with bonding plaster as per manufacturer" specification in superstructure above plinth level upto floor V panel.Gypsum blocks will have a minimum compressive strength of 9.3 Per Kilogramme/cm2 Gypsum panel partitions including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

10

-

-

... More
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board confirming to IS ; 12823 Grade I Type II,in panelling fixed in aluminium doors,windows shutters etc.complete Prelaminated particle board with decorative lamination on both sides including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

4

-

-

... More
Providing and laying APP 3mm thick(Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/Per Square Metre by the same membrane manufacture of density at 25°C, 0.87-0.89 Per Kilogramme/litre and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

21

-

-

... More
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to thewoven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

8

-

-

... More
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

28

-

-

... More
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

2

-

-

... More
Providing and fixing precoated galvanised iron profile sheets {size,shape and pitch of corrugation as approved by Engineer-in- Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per Per Square Metre as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontaV vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make TATA/Jindal or equivalent.

580

-

-

... More
Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per Per Square Metre as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make TATA/Jindal or equivalent.

-

-

-

... More
Ridge plain (500 -600 mm)

72

-

-

... More
Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per Per Square Metre as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make TATA/Jindal or equivalent.

-

-

-

... More
Gutter (600 mm over all girth)

140

-

-

... More
Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per Per Square Metre as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make TATA/Jindal or equivalent.

-

-

-

... More
Flashings/ Aprons.( Upto 600 mm)

160

-

-

... More
12 mm cement plaster in single coat on fair /rough side of brick/concrete/stone walls for External and internal plastering upto all heights and above including arises, internal rounded angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:6 ( 1 cement : 6 sand) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

1962.63

-

-

... More
18 mm cement plaster in single coat on fair /rough side of brick/concrete/stone walls for External and internal plastering upto all heights and above including arises, internal rounded angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:6 ( 1 cement : 6 sand) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

1207.54

-

-

... More
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make ASIAN/Nerolac or equivalent

1215

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make ASIAN/Nerolac or equivalent

1106.93

-

-

... More
Wall painting with acrylic emulsion paint two coats , having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make ASIAN/Nerolac or equivalent

1106.93

-

-

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 Per Square Metre) over and including priming coat of exterior primer applied @ 2.20Per Kilogramme/10 Per Square Metre including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make ASIAN/Nerolac or equivalent

734.54

-

-

... More
Finishing walls with water proofing cement paint of required shade.New work ( two or more coats appiied @ 3.84 Per Kilogramme/10 Per Square Metre )including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make ASIAN/Nerolac or equivalent

429

-

-

... More
Applying priming coats with ready mixed zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make ASIAN/Nerolac or equivalent

607.88

-

-

... More
Painting with black anti corrosive bitumastic paint of approved brand and manufature ti give an even shade Two or more coats on new work including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

22

-

-

... More
Paiting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade. Two or more coats on new work over an unde coat of suitable shade with ordinary paint including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make ASIAN/Nerolac or equivalent

668

-

-

... More
Painting with aluminium paint of approved brand and manufacture to give an even surface Two or more coats on new work including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

10

-

-

... More
Finishing with Epoxy paint ( two or more coats ) on steel at all locations prepared and applied as per manufacture's specification including appropriate priming coat,preparation of surface etc.complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make ASIAN/Nerolac or equivalent

394

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. MAke Jindal or equivalent.

-

-

-

... More
For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)

492

-

-

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)

1870

-

-

... More
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

251.6

-

-

... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 Per Kilogramme, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

-

-

-

... More
With brass cover plate minimum 1.25 mm thickness

38

-

-

... More
With brass cover plate minimum 2.25 mm thickness

1

-

-

... More
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

321

-

-

... More
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

-

-

-

... More
Anodized (AC 15 ) aluminium tubular handle bar pain

77

-

-

... More
Anodized (AC 15 ) aluminium tubular handle bar designed

1

-

-

... More
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

35

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

24

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

-

-

-

... More
With float glass panes of 8 mm thickness

56

-

-

... More
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

313

-

-

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- Per cubic Metre-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:

-

-

-

... More
b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.

-

-

-

... More
c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.

-

-

-

... More
d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.

-

-

-

... More
e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, roviding suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid,installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and unctional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and rotection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance haracteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin-Charge.

-

-

-

... More
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in Per Square Metre. up to two decimal places.

-

-

-

... More
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Per Square Metre from the certified laboratories ccreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable eparately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331- 09 testing method for a range up to 2000 ml.” Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml” Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME- 330-10 testing method for a range upto 50 mm” Seismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml” Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml

71

-

-

... More
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part- III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved anufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi- metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

123

-

-

... More
Supplying and stacking of hard stone ( for stone ptching ) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. 22.5cm thick

210.92

-

-

... More
Dry stone pitching 22.5cm thick laid in courses and required proile with hammer dressed stone having no side less than 15 cm with minimum depth of 20cm including preparing the bedding surface etc.all complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

706.15

-

-

... More
Supplying and fixing rolling shutters of approved make ,made of required size M.S.Laths,interlocked together through their entire length and jjointed together at the end by end locks,mounted on specially designed pipe shaft with brackets,side guides and arrangement for inside and outside locking with push and pull operation complete,including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adeuate strength confirming to IS.4454 PART 1 and m.s.top cover of required thickness for rolling shutters including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

-

-

-

... More
80x1.25mm m.s.laths with 1.25mm thick top cover

15

-

-

... More
Providing & fixing ball bearing for rolling shutters

2

-

-

... More
Structural steel work riveted,bolted or welded in built up sections,trusses and framed work,including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer all complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

27402.25

-

-

... More
Steel work welded in built up sections / framed work including cutting,hoisting,fixing in position and applyinga priming coat of approved steel primer using structural steel etc.as required including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make TATA/Sail/Jindal or equivalent.

-

-

-

... More
In grating,frames,guard bar,ladder,railing,brackets,gates and similar works.

6634.75

-

-

... More
Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10cm length and drilled holes upto 10mm dia. etc.complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make TATA/Sail/Jindal or equivalent.

3586

-

-

... More
Chequerred precast cement concrete tiles 22 mm thick in foot path on 20 mm thick bed of cement mortar (1:4). Dark shade using ordinary cement including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make TATA/Sail/Jindal or equivalent.

4

-

-

... More
Providing and fixing G.I.chain link fabric fencing of required width in mesh size 50x50mm including strengthening with2mm dia.wire or nuts,bolts and washers as required complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

-

-

-

... More
made of G.I.wire of dia.4 mm PVC coated to achieve uter dia not less than 5mm in required colour and shade.

772.2

-

-

... More
Providing and applying tack coat using bitumen emulsion conforming to lS: 8887, using emulsion pressure distributer including preparing tho surface & cleaning with mechanical broom. With medium setting bitumen emulsion On W.B.M / W.M.M. @ 0.4k9/Per Square Metre including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

746.72

-

-

... More
Providing and applying tack coat using bitumenEmulsion conforming to lS: 8887, using emulsion pressure distributer including preparing the surfaca & cleaning with mechanical broom. With medium setting bilumen emulsion On biluminous surface @ 0.25Per Kilogramme /Per Square Metre including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

746.72

-

-

... More
Providing and laying Dense Graded Bituminous Macadam Using Crushed Stone aggregates of specified grading. Premixed with bituminous binder and filler, transporting the hot mix to work site by tippers,laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled vibratory and tandem rollers as per specifications to achive the desired compaction and density.Complete as per specifications and directions of Engineer -In -Chrage. 50-100mm averge compact thickness with bitumen of grade VG-30 @ 5.5 % (percentage by weight of total mix) and lime filler @3% (Percentage by weight by agreegate) prepared in Batch Type hot mix plant of 100-120TPH capacity including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

38

-

-

... More
Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler transporting the hot mix fo. wark site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and densily as per specification, complete and as per directions of Engineer-in-Charge.40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

30

-

-

... More
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts,laying in uniform layers with mechanical paver] finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 ta 10) tonne capacity to achievethe desired density, complete as per specifications including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

130

-

-

... More
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road! marking paint of superior make as approved by the Engineer-incharge, ic cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and| lining out complete.New work (Two or mare oats) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

60

-

-

... More
Painting road surface marking with adequate nos of] coals to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete.New Wark (Two or more coats) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

41

-

-

... More
Providing and laying NTC make 80 mm thick factiory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick” compacted bed of coarse sand, filing the joints with line sand etc. all complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

989

-

-

... More
Granular Sub-Base with Coarse Graded Material (Table:- 400-1 & 400-2) Construction of granular subbase by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface to required gradient, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve at least 98% of maximum dry density (determined using Modified Prcctor Test), to achieve at least 30% of CBR Value, complete as per Clause 401 of MORTH 5th Revision. For Grading (iii) Material

890

-

-

... More
Dry Lean Cement Concrete Sub-base:- Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 1S:383, aggregate gradation after blending to be as per Table 600-1 of MORTH 5th Revision, with minimum cement content of 150 Per Kilogramme/Per cubic Metre or as per mix design (whichever is more), Concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-12 tonnes vibratory roller, finishing and curing. Complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

150

-

-

... More
Providing and laying design mix cement concrete of M-30 grade in road/taxi tracks/runways,using cement concrete as per design mix,using coarse sand and graded stone aggregate of 40mm nominal size in approprite propoertions as per approved & specified design criteria,providing dowel bars with sleevel/tie bars wherever required,laying at site,spreading and compacting mechanically by using needle and surface vibrators,levelling to required slope/camber,finishing with required texture,including steel form with sturdy M.S.Channel sections,curing,making provision for traction/expansion,construction & longitudinal joints ( 10mm wide x 50mm deep ) by groove cutting machine,providing and filling joints with approved joint filler and sealants,complete all as per direction of Engineer in charge ( Item of joint fillers,dowel bars with sleeve/tie bars to be paid separately ) cement concrete prepared with batch mixing machine including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

239

-

-

... More
Extra for providing and laying in position site batched design mix of cement concrete of M40 grade with minimum cement content of 390 Per Kilogramme/Per cubic Metre.Note : 1) Rate diffeerence of CPWD DSR 2023 Item no. 5.33.1,2 (M30 grade design mix concrete) and Item No.5.33.1.4 (M40 grade design mix concrete) considered. 2) Note : Extra cement upto 10 % of the minimum specified cement content in design mix is more than 1.10 timess of the sepcified minimum cement content,the conttractor shall have sicretion to either re-design the mix or bear the cost of extra cement.

239

-

-

... More
Providing and fixing pre moulded joint filler in expansion joints of RCC /CC pavements after making the joints dust free with high pressure air jet cleaners,all complete as per direction of the Engineer in charge.( Pre moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having ompresnation more than 35% confirming to IS 1838 for fibre board and IS 1834 for hot sealing bitumen compound grade A ) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

20000

-

-

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC sructures like retaining walls of the basement,wter tanks,roof slabs, podiums, reservoir,sewage & water treatment plant, tunnels/subway and bridge deck etc. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

-

-

-

... More
For vertical surface two coats

96

-

-

... More
For horizontal surface one coats

40

-

-

... More
Grading roof for water proofing treatment with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

9

-

-

... More
Providing and placing in position suitablr PVC water stops confirming to IS : 12200 for construction expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc.complete.Dumb bell central bulb ( 180mm wide 8mm thick ) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

10

-

-

... More
Supplying and fixing of Padler flanges of 100mm dia. As per approved design including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

4

-

-

... More
SANITARY INSTALLATIONS Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make Jaquar or equivalent

12

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make Jaquar or equivalent

-

-

-

... More
White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

12

-

-

... More
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.Make Jaquar or equivalent

5

-

-

... More
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. Make Jaquar or equivalent

-

-

-

... More
15 mm nominal bore

2

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.Make Jaquar or equivalent

-

-

-

... More
15 mm nominal bore

12

-

-

... More
Providing and fixing toilet paper holder : including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.Make Jaquar or equivalent

-

-

-

... More
C.P. brass

12

-

-

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.Make Jaquar or equivalent

12

-

-

... More
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.Make Jaquar or equivalent

12

-

-

... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.Make Jaquar or equivalent

-

-

-

... More
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.

12

-

-

... More
Providing and fixing of CP brass Health faucet with 8mm dia 1Per running Metre. Long PVC tube and wall hook fixed to wall with rawl plug and CP brass screws complete.including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge (Make: Jaquar Cat. No.(ALD-CHR-573) or equivalent make as approved by Engineer-in-Charge)

12

-

-

... More
Prividing and Fixing 1.5 feet long connecting hose with nuts at both ends complete. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge (Make: Jaquar Cat.No.(ALD- CHR-805B) or equivalent make as approved by Engineer- in-Charge) for health faucet

12

-

-

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge :Kitchen sink with drain board 510x1040 mm bowl depth 250 mm

2

-

-

... More
Providing and fixing J shaped Sink Cock including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge (Make: Jaquar Cat.No.(5347N) or equivalent make as approved by Engineer-in-Charge)

2

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge Concealed work, including cutting chases and making good the walls etc.

-

-

-

... More
20 mm nominal dia Pipes

73.76

-

-

... More
25 mm nominal dia Pipes

1.81

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge Internal work - Exposed on wall

-

-

-

... More
25 mm nominal dia Pipes

45

-

-

... More
32 mm nominal dia Pipes

18.07

-

-

... More
40 mm nominal dia Pipes

56.58

-

-

... More
50 mm nominal dia Pipes

3.66

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

-

-

-

... More
25 mm nominal bore

10

-

-

... More
32 mm nominal bore.

2

-

-

... More
40 mm nominal bore

2

-

-

... More
50 mm nominal bore

2

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

-

-

-

... More
20 mm nominal bore

10

-

-

... More
25 mm nominal bore

1

-

-

... More
Providing and fixing rectangular high density polyethylene water storage loft tank with cover,conforming to ISI:12701,colour of opaque white or as approved by engineer-in-charge.the rate includes making necessary holes for inlet,outlet & over flow pipes.the base support including fittings & fixtures for tank shall be paid separately. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

20000

-

-

... More
Providing and fixing in position uPVC SWR floor trap conforming to IS:13592 including providing necessary steel support and as per Specification. Making proper connection cutting chase / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position complete as required. The hopper and trap shall be set in cement concrete mix 1:2:4 complete as required. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge (P/S trap) Make: Astral/Ashirvad/Prince or equivalent as approved by engineer-in-charge. (110X110mm)

27

-

-

... More
Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For Rain water pipes). Nothing extra will be paid for supports.(Inside Toilets, Kitchen).Make: Make: Astral/Ashirvad/Prince or equivalent as approved by engineer-in-charge.including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge 160 mm outer dia

32.28

-

-

... More
Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid for supports.(Inside Toilets, Kitchen).Make: Make: Astral/Ashirvad/Prince or equivalent including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge 110 mm outer dia

105.37

-

-

... More
Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid for supports.(Inside Toilets, Kitchen) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge .Make: Astral, Ashirvad & Prince 75 mm outer dia

132.03

-

-

... More
Providing, laying and fixing P.V.C. pipe of dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Inside Toilets) including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge .Make: Astral, Ashirvad & Prince 40 mm outer dia

57

-

-

... More
Providing and Fixing in position UPVC ultra violet stabilized 110mm outer diameter cowl dome confirming to I.S.4985 including making joints with solvent cement etc.complete. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge Make: Astral, Ashirvad & Prince

11

-

-

... More
Providing and Fixing in position UPVC ultra violet stabilized 75mm outer diameter cowl dome confirming to I.S.4985 including making joints with solvent cement etc.complete. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge Make: Astral, Ashirvad & Prince

13

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

-

-

-

... More
150 mm dia. R.C.C. pipe

47.32

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

-

-

-

... More
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 Per Kilogramme (weight of cover 23 Per Kilogramme and weight of frame 15 Per Kilogramme) :With Sewer bricks conforming to IS : 4885

10

-

-

... More
Extra for depth for manholes :Size 90x80 cm With Sewer bricks conforming to IS : 4885

2.43

-

-

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 Per Kilogramme and frame to be not less than 2.70 Per Kilogramme as per standard design: including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

-

-

-

... More
150 x 100 mm size P type 19.4.2.2 With sewer bricks conforming to IS : 4885

12

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge . External work

-

-

-

... More
40 mm nominal dia Pipes

120.05

-

-

... More
50 mm nominal dia Pipes

376.7

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

-

-

-

... More
40 mm nominal bore

2

-

-

... More
50 mm nominal bore

3

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

-

-

-

... More
150 mm dia. R.C.C. pipe

202.32

-

-

... More
250 mm dia. R.C.C. pipe

74.65

-

-

... More
450 mm dia. R.C.C. pipe

20

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

-

-

-

... More
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 Per Kilogramme (weight of cover 23 Per Kilogramme and weight of frame 15 Per Kilogramme) :With Sewer bricks conforming to IS : 4885

17

-

-

... More
Extra for depth for manholes :Size 90x80 cm With Sewer bricks conforming to IS : 4885

6.88

-

-

... More
Extra for depth for manholes Size 120x90 cm With Sewer bricks conforming to IS : 4885

10.34

-

-

... More
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 Per Kilogramme (weight of cover 108 Per Kilogramme and weight of frame 100 Per Kilogramme) :With Sewer bricks conforming to IS : 4885

15

-

-

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge upto 90 metre depth below ground level.

-

-

-

... More
All types of soil 300 mm dia

30

-

-

... More
Rocky strata including Boulders 300 mm dia

30

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge

-

-

-

... More
150 mm nominal size dia

60

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

0.56

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

0.56

-

-

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

0.56

-

-

... More
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M- 25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

1

-

-

... More
Providing and fixing in position precast RCC manhole cover and frame Rectangular shape 600x450 mm internal dimension including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

425

-

-

... More
Making soak pit 2.5m dia.3.0m deep with 45x45 cm dry brick honey comb shaft with bricks and S.W.drain pipe 100mm dia.,1.8m long complete as per standard designwith common burnt clay F.P.S.( non modular ) bricks of class designation 7.5 including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

2

-

-

... More
Providing and fixing in position pre cast R.C.C.manhole cover and frame of required shape and approved quality Circular shape 560mm internal dia. including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

4

-

-

... More
Providing and laying non pressure NP 2 class ( light duty ) R.C.C.pipes with collars jointed with stiff mixture of cement mortor in the proportion of 1:2 ( 1 cement : 2 fine sand ) including tecting of joints etc.complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

-

-

-

... More
150mm dia.R..C.C.pipe

103

-

-

... More
Fire Fighting Supplying, installing, testing and commissioning of intelligent analog adressable photothermal detector complete with mounting base complete as required including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

48

-

-

... More
Supplying & laying of 2x1.5 spmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

1700

-

-

... More
Supplying, installing, testing and commissioning of adressable manual call point complete as required including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

3

-

-

... More
Supplying, installing, testing and commissioning of adressable horn Per cubic Metre strobe complete as required including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

3

-

-

... More
Supply installation testing commisioning of 6Zone, voice alarm controller with USB, MP3 Player with seamless integration facility with main fire alarm panel for voice evacuation complete as required including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

2

-

-

... More
Supplying, erecting, testing and commissioning sound column 6Watt complete as required including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

6

-

-

... More
Supplying & installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the foloowing loop modules and capable of supportingnot less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230+-5%V, 50hz), 48hrs back-up with 24 volt seales maintenance fress batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel shall be compactible for IBMS system with all accessories. The panel shall becompactible for IBMS sytem with open protocol BACnet/ Modbus over IP complete as per specifications including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge. One Loop Panel

2

-

-

... More
Supplying & erecting Water Carbon Dioxide (CO2) fire extinguisher of 9Ltr capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

6

-

-

... More
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 Per Kilogramme. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

8

-

-

... More
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 Per Kilogramme capacity with necessary clamp for erection on wall including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

8

-

-

... More
Supplying and erecting FM 200 (Clean Agent Type) type fire extinguisher as per IS : 13849 /15683 of 4 Per Kilogramme capacity with necessary clamp for erection on wall including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

2

-

-

... More
Electrical Installation Wiring for Light Point / Fan Point / Exhaust Fan Point / Call Bell Point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable GI Box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge. )

-

-

-

... More
Group C

155

-

-

... More
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

-

-

-

... More
2 x 1.5 sq.mm + 1 x 1 sq.mm earth wire

465

-

-

... More
2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire

1096

-

-

... More
2 x 4 sq.mm + 1 x 4 sq.mm earth wire

250

-

-

... More
Supplying and Fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

-

-

-

... More
25 mm

8963.22

-

-

... More
32 mm

1480

-

-

... More
Supply and Fixing two module step type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

17

-

-

... More
Supplying and fixing suitable size GI Box with modular plate & cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

45

-

-

... More
Supplying and fixing suitable size GI Box with modular plate & cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 modular socket outlet and 5/6 A modular switch, connections etc. as required.including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

38

-

-

... More
Supply and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface / recess steel / PVC conduit as required including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge. 1 run of cable

3097

-

-

... More
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

-

-

-

... More
Telephone socket outlet

22

-

-

... More
Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as required.including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

-

-

-

... More
1 or 2 module (75mm x 75mm)

11

-

-

... More
3 module (100mm x 75mm)

16

-

-

... More
4 module (125mm x 75mm)

19

-

-

... More
6 module (200mm x 75mm)

26

-

-

... More
8 module (125mm x 125mm)

10

-

-

... More
Supplying and fixing following Modular base & Cover Plate on existing modular metal boxes etc.as required.including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

-

-

-

... More
1 or 2 module

11

-

-

... More
3 module

16

-

-

... More
4 module

19

-

-

... More
6 module

26

-

-

... More
8 module

10

-

-

... More
Supply and Fixing following way horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bars ,neutral bus bar,earth bar, din bar,interconnection powder coated,as required(with out MCB/RCCB/MCCB)including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

-

-

-

... More
6WAY (4+18), Double Door

12

-

-

... More
Supplying and Fixing 5A to 32A rating, 240/415V, 10kA, 'C' curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required.including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

-

-

-

... More
Single Pole

235

-

-

... More
Supplying and Fixing rating, double pole, 240V. Isolator in the existing MCB DB complete with connections, testing and commissioning etc.as required.including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

-

-

-

5

-

-

... More
Supplying and Fixing rating, Four pole, 415V. Isolator in the existing MCB DB complete with connections, testing and commissioning etc.as required.including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

-

-

-

9

-

-

7

-

-

1

-

-

... More
Earthing with GI earth pipe 4.5 metre long, 40mm diameter including accessories, and providing masonry enclosure with cover plate having locking arrangemet and watering pipe etc. with charcoal, coke and salt as required.including carriage of material upto all leads and lifts and as per direction of Engineer incharge.

8

-

-

... More
Providing and laying earth connection with earth electrode with 6 SWG dia GI wire in 15mm dia GI pipe from earth electrode including connection with GI thimble excavation and re-filling as required. including carriage of material upto all leads and lifts and as per direction of Engineer incharge.

85

-

-

... More
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface / recess conduit / submai wiring / cable as required. including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

85

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and re-filling the trench etc. as required.including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

-

-

-

... More
up to 35 sq.mm

170

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC / HUME / METAL Pipe as required.including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

-

-

-

... More
up to 35 sq.mm

140

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

-

-

-

... More
up to 35 sq.mm

140

-

-

... More
Supply, laying connecting and testing of multi-core telephone armoured /unarmoured cable of conductor size 0.6mm dia annealed copper conductor PVC insulated PVC sheathed jelly fitted (as per DOT specification )cable as required including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

-

-

-

... More
20 pair telephone armoured cable

180

-

-

... More
Supply and fixing connecting and testing of under noted size of solderless telephone tag block krone make in surface in wall required size of M.S. box with hinged lockable cover duly slove enamel painted. including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

-

-

-

... More
20 pair tag block

160

-

-

... More
Supplying and fixing M.S. box with modular type (RJ-45) outlet for LAN complete as required.including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

18

-

-

... More
Supply, installation, testing and commissioning of pure server based IP-PBX with 24 analog extension with CLI facilities System complete as required.including carriage of material upto all leads and lifts and as per direction of Engineer incharge. Polycab,havells make or as approved by Engineer incharge.

3

-

-

... More
Supply, installation testing and commissioning of Brodband Lan connection complete as requird with 10MBPS Speed.including carriage of material upto all leads and lifts and as per direction of Engineer incharge. make or as approved by Engineer incharge.

3

-

-

... More
Supply installation testing and commissioning of 24 port L2 Managed switch having port density 24 Nos of 10M/100M/1G RJ45 Port POE /POE + ports, 2 Nos of GbE RJ45/SFP Combo port, 1X console, available POE power 370W, 52 Gbps switching bandwidth, 8K MAC address support, support L2 feature STP, RSTP, MSTP, Support 802, 1Q VLAN, port based VLAN, 4K VLAN entries, MAC based VLAN, IP subnet based VLAN, Support IEEE 802.3ad LACP, L3 features - static routing, DHCP feature, Device Management system - topology view, floor view, map view, dashboard, traffic monitoring, cable diagnostics, CE, FCC certified.including carriage of material upto all leads and lifts and as per direction of Engineer incharge (Approved Make - Cisco/Juniper/Axis/Impulse/Mobotix/Avigilon)

3

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of 2mm thick MS sheet steel fabricated cubicle type Panel dust and vermin proof complete with hinged and locable doors. The Sheet Steel shall under go minimum eight tank treatment followed by finishing treatment of power coating with 70 micron minimum thickness. All the panels shall be floor mounted and dead front construction complete with interconnections.Note:-The Panel shall be FRONT operated with the cable entry from the top bottom. Earth bus shall be part of the panel. ( All MCB to be "C" Curve) The following provision shall be required to be made in the Distribution Panel as detailed below

-

-

-

... More
All the accessible parts shall be shrouded with 1mm thick polycarbonate /3mm thick ERP sheet and all the equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves according to the colour code. SMC shrouds and busbar support shall be used. All MCCB door handle shall be interlocked and lockable OFF position. Galvanised hardware with zinc passivation shall be used in fabrication of switchboard. Suitable Aluminium earth to be provided throughout the lenghth of switchboard. All indications lamps/ illuminated push buttons shall be LED type. Cost of all motor starter shall be fed form 440 V / 230 V Control Trasnformer. All MCCB shall be variable plug setting type with the thermal magentic Ics=100% Icu & rotary handle.All controls power wiring shall be broughtout upto cable alley in the terminal blocks. An approval shall be taken for each panel before manafacturing. Provision of one 6/16 amp socket & compartment lighting for each vertical section of main panel. All breaking capacity for MCCB to be Ics=100%Icu. All MCB to be C Curve. Incoming 1 no. of 200 Amp FP MCCB of 35 KA breaking capacity & Trip setting as required. Metering for incoming Digital Multification meter (MFM-4) with RS-485 communication port for measurment of PF, V, A & Hz, equivalent to EM6459, with CT as required Phase indicating lamps RYB with 2Amps SP MCB back up. BUSBAR Electrolytic high conductivity aluminium three phase and neutral busbar rated at 400 amps, 15KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.2 sq.mm / amp. OUTGOINGS 6 nos 63Amp 10kA 440 volt, FP MCB 1 nos 100Amp 16kA 440 volt, FP MCCB along with 100 FP Contractor 2 nos 160Amp 16kA 440 volt, FP MCCB along with 100 FP Contractor

1

-

-

... More
Providing and fixing 63 Amp FP MCCB of 16 KA breaking capacity & Trip setting as required.( MAIN LIGHT PANEL)( MAIN RAWPOER PANEL) ( MAIN EMERGENCY PANEL) including carriage of material upto all leads and lifts and as per direction of Engineer incharge

4

-

-

... More
Providing and fixing 140 Amp FP MCCB of 16 KA breaking capacity & Trip setting as required.( MAIN AC PANEL)(PUMP PANEL) including carriage of material upto all leads and lifts and as per direction of Engineer incharge

2

-

-

... More
Supplying, Fixing, testing and commissioning of recessed mounted luminaire of 34W LED 600x600 of 5700K suitable for operation on 230 volt 50 Hz, Single phase AC supply with all accessories complete for ceiling, Havells Cat No: LHEWEBP6IN1W034 or equivalent make. including carriage of material upto all leads and lifts and as per direction of Engineer incharge Make Havells,wipro,philips or as approved by Engineer incharge.

26

-

-

... More
Supplying, Fixing, testing and commissioning of recessed mounted circular 12W LED downlighter with CRCA / pressure diecast aluminium heat sink & white finish polycarbonate diffuser, complete with electronic LED driver, efficacy better than 90 lumens / watt with CRI 80 including making suitable arrangement for fixing on false ceiling & connection complete as required.. including carriage of material upto all leads and lifts and as per direction of Engineer incharge Make Havells,wipro,philips or as approved by Engineer incharge.

108

-

-

... More
Supplying, Fixing, testing and commissioning of Flood Light 70W LED light suitable for operation on 230 volt 50 Hz, Single Phase AC supply with all accessories complete as required . including carriage of material upto all leads and lifts and as per direction of Engineer incharge Make Havells,wipro,philips or as approved by Engineer incharge.

10

-

-

... More
Supplying, Fixing, testing and commissioning of 8W LED Mirror light complete as required . including carriage of material upto all leads and lifts and as per direction of Engineer incharge Make Havells,wipro,philips or as approved by Engineer incharge.

10

-

-

... More
Supply and Fixing of 6x6 Exhaust Fan for opertaion of 230V olt 50Hz ,Sinlge phase AC Supply with all accessories complete as required. . including carriage of material upto all leads and lifts and as per direction of Engineer incharge Make Havells,wipro,philips or as approved by Engineer incharge.

11

-

-

... More
Supplying, Erection, Connecting, testing and commissioning of 1200mm sweep ceiling fan with GI Fa box, blades, down rod, shackle insulator, canopy etc. including providing of electronic step regulator with faceplate matching the existing modular swithces as required including carriage of material upto all leads and lifts and as per direction of Engineer incharge Make Havells,wipro,philips or as approved by Engineer incharge.

17

-

-

... More
Supply, unloading, installation at Ground Floor, testing & commissioning of micro processor / DSP controlled 5 KVA UPS, IGBT based rectifier to achieve THDI 5% and input power factor of greater than 0.95 at 50% loading. True Online Double Conversion (VFI as per IEC 62040-3). UPS using PWM IGBT technology, 1 phase input and 1 phase 230 V output UPS system, and each comprising of the following: including carriage of material upto all leads and lifts and as per direction of Engineer incharge Make Havells,wipro,philips or as approved by Engineer incharge.

-

-

-

... More
125% rated Rectifier Per cubic Metre charger unit + 100% rated invertor, Integrated in UPS module 100% rated inbuilt static switch at the invertor output + 2 Nos 100% rated inbuilt static switches at the static bypass line 100% rated inbuilt maintenance bypass 100% rated moulded case battery circuit breaker having thermal, magnetic and Automatic U/V trip mechanics Web-enabled Monitoring and Management through SNMP protocols for multi-OS environments. 100% rated External Galvanic isolation transformers of K-13 Delta/Zigzag type for isolation of input neytral with output neutral, to be installed after UPS as shown in drawing enclosed

3

-

-

... More
Supply, unloading, installation at Basement, testing & commissioning of Lead Acid Sealed maintenance free batteries for 5KVA UPS system, for providing 15 minutes backup to 5KVA UPS for full load. The bank of batteries shall comprise required Nos of batteries complete as required. Battery sizing calculation are to be submitted for approval. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

30

-

-

... More
Supply, unloading, installation at Basement, testing & commissioning of matching cabinet/ open racks to house SMF batteries for 5KVA UPS system along with interconnecting links, MCB, etc. complete as required & as per specifications.including carriage of material upto all leads and lifts and as per direction of Engineer incharge

3

-

-

... More
Supplying, Laying, testing and commissioning of flexible single core copper cable of finolex / Skyline / Havells / Nyvin make for interconnections between UPS to UPS, UPS to batteries, UPS to Isolation Transformer, complete as required for 5KVA UPS, including providing battery circuit breakers as required. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

3

-

-

... More
Supply, installation, testing & commissioning of UPS monitoring software suitable for RJ-45 communication and capable of giving pop up messages for all alarms received from UPS. It shall be capable of following:including carriage of material upto all leads and lifts and as per direction of Engineer incharge

-

-

-

... More
giving notifications like e-mail, paging notification, broadcast notification, battery replacement notification, run event-based scripts Event logging, data logging and action logging (with date, time, description of fault and event) run the battery diagnostic test Automated unattended shutdown of computers Local notification through audible alarm Software should support Microsoft Windows NT / 2000 / Server, 2003/XP, AIX, HP-UX, Sun Solaris, Linux, Novel Netware UPS described as above complete in all respects including carriage of material upto all leads and lifts and as per direction of Engineer incharge

3

-

-

... More
Providing and fixing of self illuminated / auto glow "EXIT" signs printed on toluminescent sheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

3

-

-

... More
Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoure and overall PVC sleeved 1.1KV grade power distribution cables conforming to relevant IS code. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

-

-

-

... More
4 x 10 sq.mm Al Armoured

680

-

-

... More
4 x 16 sq.mm Al Armoured

215

-

-

... More
4 x 20 sq.mm Al Armoured

180

-

-

... More
4 x 25 sq.mm Al Armoured

115

-

-

... More
3.5 x 50 sq. mm Al Armoured

70

-

-

... More
3.5 x 70 sq.mm Al Armoured

70

-

-

... More
3.5 x 95 sq.mm Al Armoured

60

-

-

... More
Supply, installation, testing & commissioning of colour dome camera with 2MP along with suitable lens, stainless steel brush finish plate etc. complete as required & as per specifications (For Basement Lift Lobby and Entrance Hall & Terrace Lobby) including carriage of material upto all leads and lifts and as per direction of Engineer incharge

12

-

-

... More
Supply and Installation testing and commissioning 4MP Bullet camera, ONVIF profilr SNG, UL, CE, FCC certified, 1/2 8" Progressive Scan CMOS, 2.8mm to 12mm motorized varifocal lens ,min illuminated : 0.05 Lux @ ( F1 2, ACG ON), 0 Lux with IR, Shutter Speed :1/5s -1/100,000s 90dB WDR , SD card support ,Alaram trigger - 1 input /1 output , Video Compression : H 265,H 264 ,frame rate :30fps @ 3MP ,Edge analytic line crossing , perimeter intrusion , Face delection , cross counting , stationary object , In built IR LED , IR Distance upto 60 meters , IP 66, POE. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

15

-

-

... More
Supply, installation, testing and commissioning of 1 Professional DVR with 16 Video Input,H 264 Compression -D 1 Display Resolution with 2.5TB HDD, Expandable up to 8TB , Total recording Irames @ 400 fps, Recording based on Continous, Motion, Scheduled or alarm, Remote backup through TCP/P,HTTP Networkable, backup by USB/DVDWR, Client software include, POS Transcation data recording with image, Supplied with Licensed OS, keyboard & mouse, complete as required and as per specification. The DVR shall be integrated with Access control system ( Along with 2 nos. 4 TB) including carriage of material upto all leads and lifts and as per direction of Engineer incharge

3

-

-

... More
Supply, installation, testing and commissioning SAMSUNG 40" Full LED Professional Display for Monitoring with mounting accessories.including carriage of material upto all leads and lifts and as per direction of Engineer incharge

3

-

-

... More
Supply, installation, testing & commissioning of 5 metre hot dipped galvanised octagonal pole with 130 mm bottom A/F and 70 mm top A/F made upto 3 mm thick. HT sheet along with base plate of size 200x200x12 mm thick (without bracket) and including foundation along the provision of cable entry. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

22

-

-

... More
Supply at site, installation, testing & commissioning of 3-phase,415volt, 1500RPM, 50Hz, Diesel Generator set of 80KVA at 0.8 lagging diesel engine alternator set mounted on common base frame in outdoor type acoustic enclousre with built in fuel tank of required capacity along with additional day tank capacity of 990 litres including fuel piping, level indicator, and valves as required, with AMF Panel, battery, battery charger, return fuel cooler, ani vibration mounting pads including residential silencer, engine alternator,pcc based auto start & synchronization set, safeless with accessories and control cabling for AMF panel up to 50Per running Metre, length as per specfication complete as required. Diesel engine shall conform to IS:10000 and Alternator shall be self excited complete with AVR to IS:4722 including carriage of material by mechanically & manual upto all lead & lift and as per direction of Engineer incharge.

1

-

-

... More
Supplying and fixing of undermoted 'B' class MS pipe for DG exhaust complete with bends, elbow flanges etc.as required. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

-

-

-

... More
125 mm dia pipe

10

-

-

... More
Supply and fixing of 50mm thick compressed mineral wool insulation ( Rock wool) for D.G. exhaust pipe with 22 gauge aluminium sheet clading etc. as required for the under mentioned dia pipe. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

-

-

-

... More
125 mm dia pipe

10

-

-

... More
Fabrication of supports for exhaust pipe, fuel pipe or for any other purpose out of M.S. structural steel including supplying and applying of enamel paint of approved shade after one coat of steel printer of reputed company. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

1200

-

-

... More
Supplying & erecting end pole D. P. Structure for 11/0.415 KV, 100 KVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Per running Metre. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with L.T. Cable, 4 Pole MCCB 300 Amps as incomer & 6 Nos.100 Amps MCCB for outgoing circuits. transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mm x 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Per Kilogramme. iron work ) with necessary clamps, Nut-bolts. vee cross arm, top clip, insulators etc. complete with caution board & barbed wire. Pipe Type & Plate Type Earthing with suitable size Earthing Strips. D.P. Structure shall be erected in c.c. foundation complete. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

1

-

-

... More
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, oil immersed and naturally cooled outdoor type, copper wound transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40oC by thermometer in oil and 45 Degree C by the resistance in winding at full load rating, with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, with standard accessories complete with test certificate with losses below ........ Watts at 50% load, ...... Watts at 100% load as per IS:1180 - 2014 energy efficiency level II, with necessary permissions of Electrical Inspector. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

1

-

-

... More
Main Panel : ( OUT DOOR Type ) Supply & Erection of 4P MCCB of ratings 300 / 400 A with short circuit ratings of 25 KA capacity complete erected in provided enclosure & connected with extended busbars / leads or spreader links & phase barriers on incoming & outgoing side with extended rortary handle other mountings accessories duly erected in an approved manners. It includes the rate door lock, hinges, & rubber gasketing necessary hardwares & control wiring complete. ( MCCB with Thermal Magnetic ) including carriage of material upto all leads and lifts and as per direction of Engineer incharge.

-

-

-

... More
Busbar :- Copper busbar of 300 A Electrolytic Grade with colour coadiing heat shrinkable sleeves supported with epoxy & finger type insulators of 50KA ratings. Connection should be done with brass nut bolts with plain washer .Clearance should be maintain as per IS Standards between Two Busbars & Compartment. Earthing bus also provieded at the bottom from one end to unother end to connect the external earthing.

-

-

-

... More
Multifunction Meter ( Which Measures - Current, Voltage, Frequency, KWH, etc.) with CT - 1 Nos. (Secure - 445 ) LED Types of Indicating Lamps with Fuses.Set of Indicating Lamp R - Red, Y-Yellow, B-Blue, Earth Leakage Relay with CT of 0.5A to 5A setting Outgoing Side Supply & Erection of 4P MCCB of ratings 200 A with short circuit ratings of 25 KA capacity complete erected in provided enclosure & connected with extended busbars / leads or spreader links & phase barriers on incoming & outgoing side with extended rortary handle other mountings accessories duly erected in an approved manners. It includes the rate door lock, hinges, & rubber gasketing necessary hardwares & control wiring complete. ( MCCB with Thermal Magnetic ) ---do--- 4P MCCB 160 A 25 KA -----do ----- - 1 No. ---do--- 4P MCCB 100 A 16 KA -----do ----- - 1 No.Supplying & erecting & marking miniature circuit breaker (As per IS:8828 of 1996) Four pole 40 Amp 10 KA with required wiring connections & lugs ferruling at both the ends of wires etc. in provided panel board complete with terminal block of suitable ampere rating and Din rail channel. - 2 Nos. ---do--- 4P MCB 32A 10 KA ----do ----- 2 Nos.---do--- 4P MCB 25A 10 KA ----do ----- 2 Nos.---do--- 2P MCB 40A 10 KA ----do ----- 2 Nos.

-

-

-

... More
Note : - Panel should be manufactured as per approved GA Drawings. Dust proof rubber gasketing. MCCB & MCB compartments should be indipendently easily openable / lockable through SS door lock. Three Panel key provided with each panel. Panel should be mounted on M.S. stand of angle frame of 600 mm height & duly grouted with anchor fastner.

1

-

-

... More
Supply & Erection of 4P MCCB of ratings 200 A with short circuit ratings of 25KA capacity complete erected in provided enclosure & connected with extended busbars, spreader links & phase barriers on incoming & outgoing side with extended rortary handle other mountings accessories duly erected in an approved manners. It includes the rate door lock, hinges, & rubber gasketing necessary hardwares & control wiring complete. - 1 Nos.

-

-

-

... More
L.T. Panel floor mounting free standing fabricated from CRCA sheet 14 Guage including cutting bending, welding reveting etc. and painting with one coat of red oxideand 2 coats of enamel paint / powder coated compartments with hinged cover and with the following mountings complete prewired and tested ( APFC Panel ) including carriage of material upto all leads and lifts and as per direction of Engineer incharge.

1

-

-

... More
Construction : APFC Panel 415V, 50Hz, 3 Phase 3 wire, A.C.Supply. Panel Shall Be CRCA sheet metal enclosed type suitable for Free standing floor mounting. The Encloser Load Member Shall be Made of 14SWG. Door, Cover Shall be 16SWG, Gland / Top Plate Made Of 10 SWG. The Design shall be Front Type Except Incomer.The Panel Shall have IP-54 degree of protection. TPN Busbar shall have High Conductivity tinned copper Electrolatic E 91E Grade, Neutral Busbar Rating shall not be less than 50% of Phase Busbar. The Fault Level of the LT Busbar is 50KA, With Non-hygroscopic anti-tracking Material, All Bolt shall cadmium plated type. Cable entry for all panels from bottom. including carriage of material upto all leads and lifts and as per direction of Engineer incharge.

-

-

-

... More
For automode, 8 step power factor control relay unit to be provided in APFC incomer in APFC relay power factor indication digital type and auto selection with communication facility. Panel use in auto aswell as manual mode If mode selector If mode selector switch is kept in manual mode it shall be possible to switch the capacitor banks ON and OFF in any sequence. Through push buttons provided for each bank. Each bank shall also be provided with ON indication lamp. In the manual mode the following features shall be present. Between switching ON operation of banks there shall be time delay of about 70 sec. similar time delay shall be present from bank switching OFF to bank switching ON to ensure full discharged capacitor condition, to prevent dangerous system The time delays as bove shall be adjustable from 0 - 120 seconds.INCOMING : 1 no. 100 Amp 3 Pole MCCB, With 1 set of Indicating Lamp LED Type, Digital APFCR meter with MCB & Resin cast Current Transformer 1000/5A, Cl- 1, 15VA, with MCB.OUT GOING : Each bank consist of capacitor duty contactor, MCB and capacitors with required accessories. Total KVAR ratings of capacitors - 30 KVAR 1) MCB 16A - 2 Nos. Connected to 5 KVAR Bank - 4 Nos.2) MCB 10A - 2 Nos. Connected to 3 KVAR Bank - 2 Nos.3) MCB 10A -2 Nos. Connected to 2 KVAR Bank - 2 Nos.

1

-

-

... More
Supplying & erecting L.T. XLPE armoured cable 1100V. grade with I.S.I. mark stranded / Solid Aluminium with G.I.saddles screwed, with continuous 12 SWG G.I. earth wire complete erected on wall with M.S.clamps / in provided trench / in provided pipe in an approved manner. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

-

-

-

... More
A) ---do --- 31/2C X 70 Sq.mm Aluminium

50

-

-

... More
B) ---do --- 31/2C X 95 Sq.mm Aluminium

75

-

-

... More
Making trench of suitable width and depth in hard murum / tar road for laying provided LT cable of 16 sq. mm & above and covered with half round hume pipe complete as per specification no. CW-EXN-CTR including carriage of material upto all leads and lifts and as per direction of Engineer incharge

25

-

-

... More
Erecting of LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3 X 240V,50 Hz with optical & RS 232 port, backlit LCD, measures & displays trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

1

-

-

... More
Liasioning Charges for obtaining approval of the substation drawing & other offical doPer cubic Metrenetation, No obection certificate from Electrical Inspector & other PWD Officer . including carriage of material upto all leads and lifts and as per direction of Engineer incharge

1

-

-

... More
Liasioning Charges for completing all the formalities for sanctioning the load from M.S.E.D.C.L, Testing of metering cubical & other inspection on site to complete charging of the installation including carriage of material upto all leads and lifts and as per direction of Engineer incharge

1

-

-

... More
Supply, installation, testing & commissioning of 4 metre hot dipped galvanised octagonal pole with 130 mm bottom A/F and 70 mm top A/F made upto 3 mm thick. HT sheet along with base plate of size 200x200x12 mm thick (without bracket) and including foundation along the provision of cable entry. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

23

-

-

... More
Supply, installation, testing & commissioning of 4 nos of M16x450 long 'J' type EN8 grade foundation bolts along with templates including carriage of material upto all leads and lifts and as per direction of Engineer incharge.

23

-

-

... More
Supply, installation, testing & commissioning of 16 Per running Metre hot dip galvanised octagonal pole with 130 mm bottom A/F and 70 mm top A/F made upto 3 mm thick. HT sheet along with base plate of size 200x200x12 mm thick (without bracket) including carriage of material upto all leads and lifts and as per direction of Engineer incharge

2

-

-

... More
Supply, installation, testing & commissioning of 4 nos of M20x600 long 'J' type EN8 grade foundation bolts along with templates including carriage of material upto all leads and lifts and as per direction of Engineer incharge

2

-

-

... More
Supply, installation, testing & commissioning of 1 Per running Metre long hot dip galvanised Single arm Special bracket (Model : Type 5) cross arm made up of GI pipe suitable to mount on pole having top 70mm A/F. Model : Type 5 including carriage of material upto all leads and lifts and as per direction of Engineer incharge

23

-

-

... More
Supply, installation, testing & commissioning of Street Light of 30W Light Fixture including carriage of material upto all leads and lifts and as per direction of Engineer incharge

23

-

-

... More
Hi wall Split AC Unit ( Heat & cool model ) Supply , Installtion , Testing & Commissoing of Hi wall Split Unit (3 or 5 star Rating , Inverter Technogoly ) With Rotary Compressor & Cordless Control of following capacity with/floor mounted OUD Stand . including carriage of material upto all leads and lifts and as per direction of Engineer incharge

-

-

-

... More
1 TR Air - Heat & Cooled Split Unit

5

-

-

... More
1.5 TR Air - Heat & Cooled Split Unit

2

-

-

... More
2 TR Air - Heat & Cooled Split Unit

2

-

-

... More
Casstte AC Unit ( Heat & cool model ) Supply , Installtion , Testing & Commissoing of Hi wall Split Unit (2 to 5 star Rating , Inverter Technogoly or only Inverter ) With Rotary Compressor & ordless Control of following capacity with/floor mounted OUD Stand . including carriage of material upto all leads and lifts and as per direction of Engineer incharge

-

-

-

... More
3 TR Air Heat & Cooled 4 way Casstte AC Unit

4

-

-

... More
Supply, installation, testing & commissioning of the insulated refrigerant piping for all the units of Outdoor Unitsas per specifications with insulation of thick 19 mm Nitrile rubber through out the running length of the refrigerant piping. Nitrile Rubber of Density 50+/-20% ( Class O ) Per Kilogramme/m3 to interconnect Indoor & Outdoor Units for each circuit - including carriage of material upto all leads and lifts and as per direction of Engineer incharge

-

-

-

... More
Ref. Copper Piping for Casstte AC 4 TR

56

-

-

... More
Supply, installation, testing & commissioning of the insulated refrigerant piping for all the units of Outdoor Unitsas per specifications with insulation of thick 19 mm Nitrile rubber through out the running length of the refrigerant piping. Nitrile Rubber of Density 50+/-20% ( Class O ) Per Kilogramme/m3 to interconnect Indoor & Outdoor Units including carriage of material upto all leads and lifts and as per direction of Engineer incharge

-

-

-

... More
for each circuit - Ref. Copper Piping for Split AC 1 TR

53

-

-

... More
Ref. Copper Piping for Split AC 1.5 TR

40

-

-

... More
Supply, Installation, testing & commissioning of Cu/Communication shielded cabling between ODU & IDU and between ODU & central controller in flexible PVC Conduit. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

-

-

-

... More
control cabling from indoor to outdoor unit Casstte AC - 4 TR ( 3 C X1.5 sq.mm )

64

-

-

... More
power supply Cable casstte AC -4 TR indoor to Out Door ( 3 C X 2.5sq.mm)

64

-

-

... More
Supply, Installation, testing & commissioning of Cu/ Communication shielded cabling between ODU & IDU and between ODU & central controller in flexible PVC Conduit. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

-

-

-

... More
Control cabling from indoor to outdoor unit Split AC & Casstte AC( 4 C X 2.5 sq.mm )

101

-

-

... More
Supply , Installtion testing & Commissoing of PVC hard drain piiping with fitting , Valves & Insulation with 10 mm for indoorAppllication Closed Cell nitrile rubber 60+/-10 Per Kilogramme/m3. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

-

-

-

... More
19 mm Dia.

45

-

-

... More
Copper piping Try if required.

30

-

-

... More
Timer For CCTV Room

2

-

-

... More
Supply , Installtion testing & Commissoing of PVC hard drain piiping with fitting , Valves & Insulation with 10 mm for indoor Appllication Closed Cell nitrile rubber 60+/-10 Per Kilogramme/m3. including carriage of material upto all leads and lifts and as per direction of Engineer incharge

-

-

-

... More
19 mm Dia.

48

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.