Western Dedicated Freight Corridor Tender

... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Western Dedicated Freight Corridor - WDFC Tender

Works
Energy, Oil and Gas
Ireps
Opening Date6 Feb 2025
Closing Soon28 Feb 2025
Tender Amount₹ 7,42,75,008.7 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Monthly Maintenance of 132/220kV TP SF-6 Circuit Breaker 5

160

1115

178475.2

... More
Half Yearly Maintenance of 132/220kV TP SF-6 Circuit Breaker 6

16

1737

27802.88

... More
Yearly Maintenance of 132 kV/220kV TP SF-6 Circuit Breaker 7

16

2090

33440

... More
Three Yearly Maintenance of 132/220kV TP SF-6 Circuit Breaker 8

8

2090

16720

... More
Monthly Maintenance of 132/220kV Current Transformer (Protection) 9

480

551

264830.4

... More
Half Yearly Maintenance of 132/220kV Current Transformer

48

828

39758.88

... More
Yearly Maintenance of 132/220kV Current Transformer (Protection) 11

48

1115

53542.56

... More
Three Yearly Maintenance of 132/220kV Current Transformer 12

24

1115

26771.28

... More
Monthly Maintenance of 132/220kV Current Transformer (Metering) 13

2400

551

1324152

... More
Half Yearly Maintenance of 132/220kV Current Transformer (Metering) 14

240

833

200064

... More
Yearly Maintenance of 132/220kV Current Transformer (Metering) 15

240

1115

267712.8

... More
Three Yearly Maintenance of 132/220kV Current Transformer (Metering) 16

120

1115

133856.4

... More
Half Yearly Maintenance of 132/220kV Potential Transformer ( Metering PT) 17

240

551

132415.2

... More
Yearly Maintenance of 132/220kV Potential Transformer ( Metering PT) 18

240

1115

267712.8

... More
Monthly Maintenance of 120/198 kV Lightning Arrester 19

864

1400

1210377.6

... More
Quarterly Maintenance of 120/198 kV Lightning Arrester 20

216

1400

302594.4

... More
Half Yearly Maintenance of 120/198 kV Lightning Arrester 21

108

1115

120470.76

... More
Yearly Maintenance of 120/198 kV Lightning Arrester 22

108

1115

120470.76

... More
Monthly Maintenance of 132/220kV TP Motorised Isolator with or without earthing heel

460

552

254186.8

... More
Half Yearly Maintenance of 132/220kV TP Motorised Isolator with or without earthing heel 24

46

833

38345.6

... More
Yearly Maintenance of 132/220kV TP Motorised Isolator with or without earthing heel 25

46

1256

57794.4

... More
Monthly Maintenance of 55 kV Current Transformer 26

2240

551

1235875.2

... More
Half Yearly Maintenance of 55 kV Current Transformer 27

224

833

186726.4

... More
Yearly Maintenance of 55 kV Current Transformer 28

224

1115

249865.28

... More
Three Yearly Maintenance of 55 kV Current Transformer 29

112

1115

124932.64

... More
Monthly Maintenance of 55/72.2kV DP SF-6 Circuit Breaker 30

920

422

388690.8

... More
Half Yearly Maintenance of 55/72.2kV DP SF-6 Circuit Breaker 31

92

833

76691.2

... More
Yearly Maintenance of 55/72.2kV DP SF-6 Circuit Breaker 32

92

1665

153227.84

... More
Three Yearly Maintenance of 55/72.2kV DP SF-6 Circuit Breaker 33

46

1665

76613.92

... More
Monthly Maintenance of 55 /72.5 kV DP Motorised Isolator without earthing heel 34

1720

829

1426619.6

... More
Half Yearly Maintenance of 55/72.5 kV DP Motorised Isolator without earthing heel 35

172

1396

240191.12

... More
Yearly Maintenance of 55/72.5 kV DP Motorised Isolator without earthing heel 36

172

2089

359330.36

... More
Monthly Maintenance of 42/ 60 kV Lightning Arrester 37

1472

422

621905.28

... More
Quarterly Maintenance of 42/60 kV Lightning Arrester

368

422

155476.32

... More
Half Yearly Maintenance of 42/60 kV Lightning Arrester 39

-

-

38

... More
Yearly Maintenance of 42/ 60 kV Lightning Arrester 40

184

692

127451.28

... More
Monthly Maintenance of 55kV/27.5 kV, 12.3 MVA Auto Transformer 41

400

1666

666652

... More
Half Yearly Maintenance of 55kV/27.5 kV, 12.3 MVA Auto Transformer 42

40

2229

89168.8

... More
Yearly Maintenance of 55kV/27.5 kV, 12.3 MVA Auto Transformer 43

40

3485

139423.6

... More
Quarterly Maintenance of 25 kV Potential Transformer Protection PT 44

80

551

44138.4

... More
Half Yearly Maintenance of 25 kV Potential Transformer Protection PT 45

40

833

33355.2

... More
Yearly Maintenance of 25 kV Potential Transformer Protection PT 46

40

1115

44618.8

... More
Monthly Maintenance of 25 kV Current Transformer at Auto Transformer 47

800

551

441384

... More
Half Yearly Maintenance of 25 kV Current Transformer 48

80

833

66710.4

... More
Yearly Maintenance of 25 kV Current Transformer 49

80

1115

89237.6

... More
Three Yearly Maintenance of 25 kV Current Transformer 50

40

1115

44618.8

... More
Monthly Maintenance of 25 kV DP Circuit Breaker 51

400

422

169120

... More
Half Yearly Maintenance of 25 kV DP Circuit Breaker 52

40

833

33344

... More
Yearly Maintenance of 25 kV DP Circuit Breaker 53

40

1667

66688.4

... More
Monthly Maintenance of 25 kV DP Motorised Isolator without earthing heel 54

800

833

667104

... More
Half Yearly Maintenance of 25 kV DP Motorised Isolator without earthing heel 55

80

1397

111787.2

... More
Yearly Maintenance of 25 kV DP Motorised Isolator without earthing heel 56

80

2090

167200

... More
Monthly Maintenance of 25 kV DP Interrupter 57

200

422

84560

... More
Half Yearly Maintenance of 25 kV DP Interrupter 58

20

833

16672

... More
Yearly Maintenance of 25 kV DP Interrupter 59

20

1667

33344.2

... More
Quarterly Maintenance of 25kV/240V, 100kVA LT Auxiliary Transformer 60

40

422

16912

... More
Half Yearly Maintenance of 25kV/240V, 100kVA LT Auxiliary Transformer 61

20

833

16672

... More
Yearly Maintenance of 25kV/240V, 100kVA LT Auxiliary Transformer 62

20

2230

44618.8

... More
Monthly Maintenance of 55kV/0.65 kV, 3 MVA Transformer capacitor bank 63

200

422

84498

... More
Half Yearly Maintenance of 55kV/0.65 kV, 3 MVA Transformer capacitor bank 64

20

829

16588.6

... More
Yearly Maintenance of 55kV/0.65 kV, 3 MVA Transformer capacitor bank

20

2229

44584.4

... More
Quarterly maintenance of 2500 KVAR CAPACITOR BANK INCLUDING SERIES REACTOR 66

40

833

33344

... More
Half yearly maintenance of 2500 KVAR CAPACITOR BANK INCLUDING SERIES REACTOR 67

20

2230

44618.8

... More
Yearly maintenance of 2500 KVAR CAPACITOR BANK INCLUDING SERIES REACTOR 68

20

3346

66928.2

... More
Quarterly Maintenance of 25 kV Neutral Current Transformer 69

60

833

50016

... More
Yearly Maintenance of 25 kV Neutral Current Transformer 70

20

1667

33344.2

... More
Fortnightly battery & battery charger maintenance of TSS 71

220

551

121380.6

... More
Yearly battery & battery charger maintenance of TSS 72

10

13373

133736.6

... More
Half Yearly maintenance of Earthing station 73

874

211

184772.34

... More
Yearly maintenance of Earthing station 74

874

211

184772.34

... More
Yearly maintenance of Buried Rail Connection 75

10

22297

222974.2

... More
Half Yearly maintenance of Thermal Imaging of Equipment connector 76

3000

551

1655190

... More
Yearly Maintenance of Earth Screen Conductor 77

10

2090

20900

... More
Yearly maintenance of Cable Trench Cleaning 78

10

11142

111427.1

... More
Reclamation of DCP (5kG,10 kG & 25 kG),CO2(9kG) & foam type fire extinguisher. 79

20

84

1688

... More
Refilling of DCP(5kG,10 kG & 25 kG),CO2(9kG) & foam type fire extinguisher.

20

687

13749.2

... More
Monthly Maintenance of 8 MVA Auto Transformer 2

800

1666

1333304

... More
Half Yearly Maintenance of 8 MVA Auto Transformer 3

80

2229

178337.6

... More
Yearly Maintenance of 8 MVA Auto Transformer 4

80

3485

278847.2

... More
Monthly Maintenance of 25 kV Current Transformer at Auto Transformer 5

1600

551

882768

... More
Half Yearly Maintenance of 25 kV Current Transformer 6

160

833

133420.8

... More
Yearly Maintenance of 25 kV Current Transformer 7

160

1115

178475.2

... More
Three Yearly Maintenance of 25 kV Current Transformer 8

80

1115

89237.6

... More
Monthly Maintenance of 25 kV DP Circuit Breaker 9

50

422

21140

... More
Half Yearly Maintenance of 25 kV DP Circuit Breaker 10

50

833

41680

... More
Yearly Maintenance of 25 kV DP Circuit Breaker 11

50

1667

83360.5

... More
Monthly Maintenance of 25 kV DP Interrupter

2420

422

1023176

... More
Half Yearly Maintenance of 25 kV DP Interrupter 13

-

-

12

... More
Yearly Maintenance of 25 kV DP Interrupter 14

242

1667

403464.82

... More
Monthly Maintenance of 25 kV DP Isolator (Manual ) 15

6080

829

5042934.4

... More
Half Yearly Maintenance of 25 kV DP Isolator (Manual ) 16

608

1397

849582.72

... More
Yearly Maintenance of 25 kV DP Isolator (Manual ) 17

608

2090

1270720

... More
Monthly Maintenance of 25 kV SP Isolator (Manual ) 18

520

422

219694.8

... More
Half Yearly Maintenance of 25 kV SP Isolator (Manual ) 19

52

833

43347.2

... More
Yearly Maintenance of 25 kV SP Isolator (Manual ) 20

52

1256

65332.8

... More
Quarterly Maintenance of 25 kV Potential Transformer (Type-I) 21

180

551

99311.4

... More
Half Yearly Maintenance of 25 kV Potential Transformer (Type-I) 22

90

833

75049.2

... More
Yearly Maintenance of 25 kV Potential Transformer (Type-I) 23

90

1115

100392.3

... More
Quarterly Maintenance of 25 kV Potential Transformer (Type-II) 24

80

551

44138.4

... More
Half Yearly Maintenance of 25 kV Potential Transformer (Type-II) 25

40

833

33355.2

... More
Yearly Maintenance of 25 kV Potential Transformer (Type-II) 26

40

1115

44618.8

... More
Monthly Maintenance of 42 kV Lightning Arrester 27

5472

422

2311865.28

... More
Quarterly Maintenance of 42 kV Lightning Arrester 28

1368

422

577966.32

... More
Half Yearly Maintenance of 42 kV Lightning Arrester 29

684

692

473786.28

... More
Yearly Maintenance of 42 kV Lightning Arrester 30

684

692

473786.28

... More
Quarterly Maintenance of 25kV/240V, 10kVA LT Auxiliary Transformer 31

272

422

115001.6

... More
Half Yearly Maintenance of 25kV/240V, 10kVA LT Auxiliary Transformer 32

136

833

113369.6

... More
Yearly Maintenance of 25kV/240V, 10kVA LT Auxiliary Transformer 33

136

2230

303407.84

... More
Fortnightly battery & battery charger maintenance at SCPs 34

2992

551

1650776.16

... More
Yearly Maintenance of Battery AND Battery Charger 35

68

13373

909408.88

... More
Half Yearly maintenance of Earthing station 36

1696

211

358551.36

... More
Yearly maintenance of Earthing station 37

1696

211

358551.36

... More
Yearly Buried Rail Connection 38

30

22297

668922.6

... More
Monthly Maintenance of 25 kV SP Interrupter

260

422

109928

... More
Half Yearly Maintenance of 25 kV SP Interrupter 40

26

833

21673.6

... More
Yearly Maintenance of 25 kV SP Interrupter 41

26

1667

43347.46

... More
Half Yearly Thermal Imaging of Equipment connector 42

4208

551

2321679.84

... More
Yearly Maintenance of Earth Screen Conductor 43

68

2090

142120

... More
Yearly maintenance of Cable Trench Cleaning 44

68

4461

303408.52

... More
Reclamation of DCP(5kG,10 kG & 25 kG),CO2(9kG) & foam type fire extinguisher. 45

136

84

11478.4

... More
Refilling of DCP(5kG,10 kG & 25 kG),CO2(9kG) & foam type fire extinguisher.

136

687

93494.56

... More
Monthly panel maintenance in TSS 2

120

3446

413598

... More
Monthly panel maintenance in SP/SSP 3

816

1723

1406229.12

... More
Half yearly Cross gantry or any others Gantry Bus Bar maintenance of TSS 4

20

19957

399155

... More
Half yearly Cross gantry or any others Gantry Bus Bar maintenance of SP/SSPs 5

120

13787

1654549.2

... More
Half yearly Cross gantry or any others Gantry Bus Bar maintenance of PPs 6

16

6893

110303.36

... More
Removal and re-erection of PSI Equipment 7

20

6894

137892.2

... More
Supply & Erection of Caution Board 8

100

370

37002

... More
Supply and spreading of ballast/Pebbles/Gravels in Switching Stations/TSS yard 9

500

1665

832825

... More
Reinforce concrete for cable trench & cover

250

1603

400790

... More
Supply and repainting of PSI Equipment like Transformer CT ,PT ,LA , BM, CB, AT as per site requirement with water proof grey enamelled paint by approved brand i.e. Asian Berger etc. as per IS 2932 or latest

4000

47

188480

... More
Supply and repainting of PSI assets i.e.. Fencing Panels, Fencing UP right, barbared wire, Tubular pole at TSS/SP/SSP with Aluminum Paint i.e. Asian Berger etc. as per IS 2339 or latest 12

8000

43

344240

... More
Supply and erection of Earth Pit cover & Box 13

75

1094

82053

... More
Provision of Shock Treatment Chart 14

50

1050

52510

... More
Drilling of holes in mast/ rails with contractor own labour and T&P complete. 15

40

45

1818.4

... More
Monthly removal of Wild vegetation in TSS/SP/SSPs

62040

12

763092

... More
Supply and erection of earth leads 75 x 8 mm mild steel flat laid in the ground or exposed as per site requirement

200

313

62786

... More
Supply and erection of earth leads 50 x 6 mm mild steel flat laid in the ground or exposed as per site requirement

500

174

87270

... More
Supply and erection of 8 SWG GI Wire for earthing

-

-

18

... More
Loading, Unloading & Transportation of DFCCIL Supplied material (Applicable for material more than 2 MT) -(Each occasion) 20

50

4093

204690

... More
Hiring of 15T crane on hourly basis

50

1785

89295

... More
Supply, fixing & commissioning of 300 mm sweep exhaust fan with louver shutter. As per specification.

20

1459

29197.8

... More
Supplying and Fixing of fire bucket stand made out of MS angle with one coat of primer 22 and two coat of enamel paint of approved shade including platform and associated civil works each stand should have four nos fire buckets of 24 gauge galvanized steel sheet, standard 9 liter capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters "Fire" in black and gold at approved location as per direction of Engineer in charge.

20

3903

78079.2

... More
Supply of First Aid Box made of GI/AL Sheet, ISI Marked filled with Medicines as per Railway standards with suitable locking arrangement & approved by DFCCIL

40

2525

101016.4

... More
Supply and fixing of 160W or above LED Floodlight comprising Die cast aluminium housing with toughened glass complete with Electronic driver, Luminaries has the System lumen efficacy of 100 lumen/Watt as per specification.

20

20262

405256.4

... More
Rubber mat (ISI marked) non stick type suitable for 11 kv AC supply of size 2000x1000x25mm as per specification.

50

896

44844

... More
Supply and erection of earth lead using 75x8 mm GI flat laid in ground/exposed as per the site requirement. 27

500

854

427225

... More
Supply of Fire Buckets of 10 Ltrs capacity 28

40

387

15516

... More
Regular House Keeping of TSS 2

3650

728

2660704

... More
Manning of TSS

10950

1203

13175806.5

... More
Breakdown attention of PSI equipments at TSS/SP/SSPs 2

180

740

133297.2

... More
Maintenance of 25 KV dropout fuse AT TSS/SP/SSP 3

50

1240

62040

... More
Manning of SP/SSP in case of Emergency

120

1468

176221.2

... More
Excavation and casting foundation and plinth by Concrete in all kind of soil including hard soil and rocky soil

25

9900

247513.25

... More
Dismantling, supply, erection & commissioning of LA, CT, PT, CB & BM in case of break down/bursting of the equipment- As per Appendix-A

-

-

2500000

... More
Maintenance of Traction Sub Stations /SCPs (Optional)

-

-

500000

... More
Maintenance & Replacement of OEM Recommended spare including Erection chares @ 10 %

-

-

2500000

... More
Any Civil work in CPWD DSR 2021 consider rate 38 % below as per Railway board letter no. HQ0ENGG (WKS)/73/2021 dated 19.01.2023

-

-

1500000

... More
Screwdriver 6",8",10" 2

8

363

2910.96

... More
Cutting pliers 8" 3

8

272

2183.2

... More
Line tester 4

16

69

1112.96

... More
Nose Pliers 6" 5

8

278

2226

... More
"Double open-ended Spanner (6 to 32)" 6

8

1005

8047.92

... More
Measuring Tape 5m 7

4

178

714.88

... More
Adjustable wrench 8" 8

4

631

2525.68

... More
Ball pen Hammer 500gm 9

8

369

2953.76

... More
Combination plier, 280mm 10

8

278

2226

... More
Allen key 2 to 16mm 11

8

663

5308.16

... More
1/2" Socket set containing 19 socket with 6 attachment 12

4

5056

20226.8

... More
Crimping tool up to 16mm 2 sizeNos 13

4

877

3510.24

... More
Pipe wrench 8", 12"

4

829

3317.64

... More
Contact less thermo meter 15

4

2386

9546.2

... More
Adjustable spanner 8",12" 16

8

1177

9417.76

... More
Ring spanner (6 - 41) 17

8

1551

12414.32

... More
DE spanner (6- 41) 18

8

973

7791.04

... More
Desoldering iron 19

2

1262

2525.68

... More
Soldering iron 60 W 20

2

492

984.58

... More
Wire stripping pliers, 150mm 21

8

80

642.16

... More
Hydraulic crimping machine up to 300mm2 22

2

5672

11344.12

... More
Manila rope 15, 25mm dia (20 m Each) 23

4

5211

20847.48

... More
Nylon rope 15, 25, 40mm dia (20 m Each) 24

4

4837

19349.2

... More
Digital spirit level 25

4

1262

5051.36

... More
Digital Vernier calliper 26

5

2710

13554.1

... More
Digital micrometre 27

2

2584

5169.06

... More
Round cable and wire cutter, 900mm 28

8

3574

28595.76

... More
Grease gun 29

4

788

3154.96

... More
Bolt cutter 12", 36" 30

4

2188

8754.24

... More
Steel Tape (3m, 5m, 15m) 31

4

684

2739.72

... More
Sledgehammer 1kg, 5kg 32

4

3986

15946

... More
Flat file/250mm 33

4

256

1027.4

... More
Round file,288m 34

4

358

1434.08

... More
Triangular file,288 mm 35

4

321

1284.24

... More
Half round file,250mm 36

4

406

1626.72

... More
Flat Chisel, 10" 37

4

203

813.36

... More
Pin punch, 10" 38

4

181

727.72

... More
Centre punch 39

4

192

770.56

... More
Inner circlip pliers straight nose,19-60 mm Capacity 40

4

342

1369.84

... More
Inner circlip pliers bent nose, 19-60 mm Capacity 41

4

315

1262.84

... More
Torque Wrench, 60-330 Nm

2

6581

13163.46

... More
Digital Earth tester Model No. btc - 96 43

-

-

42

... More
Handheld electric blower 44

2

2546

5092.02

... More
Portable Electric grinder 45

2

3836

7673.34

... More
Acidity testing kit 46

5

3253

16267.05

... More
Portable electric Hand Drill Machine 47

2

6635

13270.48

... More
Digital multimeter 48

4

2001

8005.08

... More
Oil BVD testing kit 49

1

227310

227310.48

... More
Discharge Rod high rise 50

8

24133

193064.08

... More
Drop out fuse Operating rod 51

4

8422

33689.88

... More
Single Sleeve pulley Fiber 3.5"x0.5 52

10

786

7866

... More
Single Sleeve pulley steel 3.5'x0.5 53

10

898

8989.7

... More
"Al Ladder 8 Meter with Hook on Top" 54

4

8657

34631.68

... More
Hot stick suitable for High Rise 55

2

10648

21296.98

... More
Clip on Tong Tester 56

5

3157

15785.45

... More
Supply of 5 kV Insulation Tester 57

3

99690

299072.73

... More
Measuring Tape 15 Meter PVC 58

4

363

1455.48

... More
Measuring Tape 30 Meter PVC

4

449

1797.92



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.