If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Urban Development Authority Tender

Works
Coronavirus COVID 19
Eprocure
Opening Date8 Feb 2019
Closing Date21 Feb 2019
Tender Amount₹ 3,98,25,000 
Notes
Download

Costs

Summary

Providing Furniture And Execution Of Interior Works Audio Video In The New Office Building In Site No.3, Madhya Marg, Sector 18a, Chandigarh Including One Year Maintenance And Defect Liability Period Free Of Cost.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
VISITOR'S CHAIR FOR DIRECTOR'S+CTP+ CTP IT& M, COMMISSONER & CCPNCR CABIN TABLE: MID BACK VISITOR'S CHAIR FOR STP (E), STP (MONITORING), DTP (1,2,3,4,&5) MID BACK WITH MOULDED MESH BACK WITH FIXED ARMREST & CANTALEVER BASE All Dim in MM with open tolerance of +/- 10mm and ANSI / BIFMA/X5.1 compliant chair BACKREST : The back shall be made up PP as Outer Frame, ABS Inner frame &Upholstery with Fabric mesh, The back shall be designed with contoured inbuilt lumber support for achieving comfortable seating posture. Back rest size - Mid Back (HB) 740-790mm (H) X 480- 500mm (W). The backrest tested for 1,20,000 cycles to be completed with a load of 44.5Kg as per ANSI / BIFMA X5 (The description has been described fully at Sr. No.4 at page no.32 & 33 of DNIT)

24

-

-

... More
CATEGORY- A I.E. PREMIUM 3-SEATER SOFA 2010(W)X900(D)X850(H) Director, C.T.P, C.T.P.(I & M) SOFA- 3 SEATER -Upperstructure shall be a single shell 1.2 ±0.1cm. thick hot pressed plywood. Dia 4mm zig-zag type assembly is mounted in the understructure for support and additional cushioning purpose. The seat is made up of PU foam with density 32+/-2 Kg/m3 having an additional top layer of PU foam with density 28+/-2 Kg/m3, upholstered with fabric or leatherette. The back is made up of 28+/-2 Kg/m3 with additional top layer of PU foam with density 23+/-2 Kg/m3, upholstered with fabric or leatherette. The leg is a welded assembly made up of stainless steel (grade SS 202) tube and plate. Overall Dimensions of Chair shall be Seat Height - 45.0 cm, Height - 82.0cm, Width & Depth of Chair as measured from pedestal - Width-205.5 cm and Depth-92.0 cm.

3

-

-

... More
CATEGORY- A I.E. PREMIUM 2-SEATER SOFA 1600(W)X900(D)X850(H) C.T.P., C.T.P (I&M), Commissioner, CCPNCR PISA SOFA- 2 SEATER Upperstructure shall be a single shell 1.2 ±0.1cm. thick hot pressed plywood. Dia 4mm zig-zag type assembly is mounted in the understructure for support and additional cushioning purpose. The seat is made up of PU foam with density 32+/-2 Kg/m3 having an additional top layer of PU foam with density 28+/-2 Kg/m3, upholstered with fabric or leatherette. The back is made up of 28+/-2 Kg/m3 with additional top layer of PU foam with density 23+/-2 Kg/m3, upholstered with fabric or leatherette. The leg is a welded assembly made up of stainless steel (grade SS 202) tube and plate. Overall Dimensions of Chair shall be Seat Height - 45.0 cm, Height - 82.0cm, Width & Depth of Chair as measured from pedestal - Width-146.0 cm and Depth-92.0 cm.

4

-

-

... More
CATEGORY- A I.E. PREMIUM 1-SEATER SOFA Director SOFA- 1 SEATER Upperstructure shall be a single shell 1.2 ±0.1cm. thick hot pressed plywood. Dia 4mm zig-zag type assembly is mounted in the understructure for support and additional cushioning purpose. The seat is made up of PU foam with density 32+/-2 Kg/m3 having an additional top layer of PU foam with density 28+/-2 Kg/m3, upholstered with fabric or leatherette. The back is made up of 28+/-2 Kg/m3 with additional top layer of PU foam with density 23+/-2 Kg/m3, upholstered with fabric or leatherette. The leg is a welded assembly made up of stainless steel (grade SS 202) tube and plate. Overall Dimensions of Chair shall be Seat Height - 45.0 cm, Height - 82.0cm, Width & Depth of Chair as measured from pedestal - Width-86.0 cm and Depth-92.0 cm.

3

-

-

... More
RELAX SOFA / FUTON Retiring room Director, Commissioner, CCPNCR Overall Dimesion : In sofa condition:-1475 (L) x 930 (W) x 800 (H) Seat Length: 1475 mmSeat Depth: 570 mmSeat Height: 480 mm In bed condition:-1990 (L) x 1475 (W) x 380 (H)

3

-

-

... More
CATEGORY- A I.E. PREMIUM 3-SEATER SOFA 2010(W)X900(D)X850(H) SOFA- 3 SEATER All Dim in MM with open tolerance of +/- 10mm Three seater Sofa: Providing and installing as per layout plan three seater sofa with SIZE : 2010(W) X 900(D) X 850(H). Inner solid Frame structure shall be made of high quality tropical Meranti wood. The wood shall be kiln chemical treated tropical Meranti wood. The legs shall be made of rubberwood having melamine matt finshall beh. The seat cushion shall be made of 7 inches multi layered foam of density 32D 23D 32D and HD with polyester polyfill outer layer of 180 gsm. (The description has been described fully at Sr. No.9 at page no.33 of DNIT)

2

-

-

... More
CENTRE TABLE : PISA CENTRE TABLE - Glass shall be 12+/-0.3mm thick black tinted toughened glass UV glued with bushes made in SS 202 grade for fixing with understructure. It shall be a welded assembly made in SS202 grade having dia. 12+/-0.04 as per IS:1762. overall dimensions of table shall be Width of table= 112.0 cm, Depth=60.0 cm, height=35.1 cm.

3

-

-

... More
SIDE TABLE 440(L)X440(D)X450(H) PISA SIDE TABLE - Glass shall be 12+/-0.3mm thick black tinted toughened glass UV glued with bushes made in SS 202 grade for fixing with understructure. It shall be a welded assembly made in SS202 grade having dia. 12+/-0.04 as per IS:1762. overall dimensions of table shall be Width of table= 60.0 cm, Depth=60.0 cm, height=35.1 cm.

15

-

-

... More
BED SIDE UNIT: 400(W)X400(D)X515(H) BED SIDE UNIT:SIZE 400mm x 400mm x 415mm All Dim in MM with open tolerance of +/- 10mm The Bed side unit shall be made up of 18 mm thick prelam particle board with both side decorative laminate. All exposed edges shall be sealed with 2 mm thick PVC Edge Banding. The bed side unit has one drawer an one shelf. The shelf shall be made up of 18 mm thick Prelam Particle board with both side decorative laminate. All exposed edges are sealed with 2 mm thick PVC edge banding.

3

-

-

... More
CABIN TABLE FOR - CTP, CTP(IT&M), CCPNCR: CABIN TABLE WITH EXTENSION TOP WITH SIDE TABLE, PEDESTAL UNIT WITH REAR STROAGE UNIT Maestro Main Desk OXFORD CHERRY size 1800 x 900 x 750 + Maestro Joining Table 1200 X 1050 X 750 + Maestro Mobile Pedestal Oxford Cherry 400 x 560 x 560 + Maestro Return Desk 1200 X 600 X 730 in mm + The main desk of Maestro shall be of size 1800 Width mm x 900 Depth mm x 750 Height mm.The table top shall be 25 mm thick MFC (Melamine Faced Chipboard) also there should be 30 mm MDF (Medium density fiberboard) black pad. (The description has been described fully at Sr. No.13 at page no.34 of DNIT)

3

-

-

... More
CABIN TABLE FOR STP (E), JOINT DIRECTOR, STP (MONITORING) MAIN TABLE WITH INTEGRATED RETURN TABLE WITH MOBILE PRELAM PEDESTAL UNIT B+F ARISTO TBL 2350 RH RU 1200 PDL - 2350x2350x750 Aristo Main desk- Work Surface-Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping.Gromet provided on work surface for wire management.Modesty Panel-Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. Under-structure-Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shadeconfirming to IS-12823:1990, (The description has been described fully at Sr. No.14 at page no.34-35 of DNIT)

3

-

-

... More
CHAIR FOR STP (E), JOINT DIRECTOR, STP (MONITORING), DTP (1,2,3,4,&5), ARCHITECT, CAO, DA, PMIT CABINS, CONFEREENCE HEAD Ace chair with head rest - The cushioned seat assembly shall consists of seat outer(material-30% glass fiber nylon) and upholstered seat inner(material-polypropylene) with moulded polyurethane foam and polyester fabric. (The description has been described fully at Sr. No.15 at page no.35 of DNIT)

15

-

-

... More
VISITOR'S CHAIR NON REVOLVING FOR STP (E), JOINT DIRECTOR, STP (MONITORING), DTP (1,2,3,4,&5) CABINS, ARCHITECT, PMIT, CAO, PMIT , DA, CONFERENCE ROOM CHAIR P.A CABIN VISITOR'S CHAIR - MEDIUM BACK IN MESH BACK WITH 4 LEGGED UNDERSTRUCTURE AND FIXED ARM All Dim in MM with open tolerance of +/- 10mm and ANSI / BIFMA/X5.1 compliant chair BACKREST : The back shall be made up of 12mm Dia MS rod and upholstered with Mesh fabric. The back frame shall be designed with contoured lumber support for achieving comfortable seating posture. Back rest size - 610mm (H) X 425mm (W). The backrest tested for 1,20,000 cycles to be completed with a load of 44.5Kg as per ANSI / BIFMA X5.1. (The description has been described fully at Sr. No.16 at page no.35-36 of DNIT)

86

-

-

... More
CABIN TABLE FOR DTP (1,2,3,4,&5), ARCHITECT, CAO , DA MAIN TABLE WITH INTEGRATED RETURN TABLE WITH MOBILE PRELAM PEDESTAL UNIT B+F Topaz MAIN TABLES with ERU attached Pedesta size 2100x2250x750lMAIN TABLE: 1950(L)X900(D)X740(H) MM, SIDE TABLE UNIT 1350(L)X500(D)X740(H) MM & PEDESTAL DRAWER UNIT I.E. B+F (400(W)X470(D)X545(H) WITH 2 NOS BACK UNIT I.E. HINGED DOOR SHUTTER UNIT 2 NOS 750(W)X425(D)X740(H) MM BACK STORAGE UNIT :- TOPAZ BCKUNT 1650W 750H size 1650x450x750

10

-

-

... More
CABIN TABLE FOR PA OF DIRECTOR'S+CTP+ CTP IT&M, COMMISSONER &CCPNCR & PMIT, DEP. IT, ATP 1,2,3,4& 5 JUNIOR ADM 1,2,3,4,& 5, KANUNGO, SUPD, ADA 1&2 MAIN CABIN TABLE WITH INTEGRATE SIDE TABLE & MOBILE PRELAM PEDESTAL UNIT B+F MAIN TABLE : 1800(L)X900(D)X740(H) , RETURN TABLE UNIT 1050(L)X525(D)X740(H) WITH MOBILE PRELAM PEDESTAL UNIT B+F 400(W)X470X(D)X545(H) + METAL KEYBOARD TRAY 19" + METAL CPU TROLLEY All Dim in MM with open tolerance of +/- 10mm Considering main & return table top shall be made of 25mm thick prelam particle board confirming to IS 12823 Interior Grade with the exposed edges sealed with 2mm PVC edge banding. The height of the table top from the ground should be 740mm. supported on the legs and beams. (The description has been described fully at Sr. No.18 at page no.36 of DNIT)

27

-

-

... More
CABIN TABLE FOR JE 1,2,3,4,PLANNING ASSISTANT 1,2,3, ATP 1,2,3, A.O, S.O CABIN TABLE WITH INTEGRATED SIDE TABLE & MOBILE PRELAM PEDESTAL UNIT B+F MAIN TABLE : 1500(L)X750(D)X740(H) , RETURN TABLE UNIT 1050(L)X525(D)X740(H) WITH MOBILE PRELAM PEDESTAL UNIT B+F 400(W)X470X(D)X545(H) + METAL KEYBOARD TRAY 19" + METAL CPU TROLLEY All Dim in MM with open tolerance of +/- 10mm Considering main & return table top shall be made of 25mm thick prelam particle board confirming to IS 12823 Interior Grade with the exposed edges sealed with 2mm PVC edge banding. (The description has been described fully at Sr. No.19 at page no.37 of DNIT)

18

-

-

... More
TABLE : FOR STENO/ SECURITY/DAIRY DISPATCH 1200(L)X600(D)X740(H) WITH MOBILE PRELAM PEDESTAL UNIT B+B+F TABLE : FOR STENO/ SECURITY DAIRY DISPATCH 1050(L)X600(D)X740(H) All Dim in MM with open tolerance of +/- 10mm MAIN TABLE 1200(L)X600(D)X740(H) WITH MOBILE PRELAM PEDESTAL UNIT B+B+F (400X470X675 MM) WITH METAL KBT & CPU TROLLEY MAIN TABLE: Main table of size 1050x600x740mm completely made up of Prelam particle board conforming to shall be : 12823 Interior Grade with PVC edge banding. Top are with 25mm thk boards with 2mm PVC edge banding with enhanced scratch resshall betance supported on 25mm thk. (The description has been described fully at Sr. No.20 at page no.37-38 of DNIT)

64

-

-

... More
CHAIR FOR RECEPTION, PA OF DIRECTOR'S+CTP+ CTP IT&M, COMMISSONER &CCPNCR , DEP IT, ATP 1,2,3,4& 5, ROOM, JUNIOR DM 1,2,3,4,& 5 , PLANNING ASST., JE, STAFF, ADA, AO, SO, IT STAFF, ADMIN STAFF, SUPD., KANUNGO, STAFF , CCP(NCR) STAFF CHAIR FOR PA OF DIRECTOR'S+CTP+ CTP IT&M, COMMISSONER &CCPNCR & PMIT, IT HEADS, ATP 1,2,3,4& 5 JUNIOR ADM 1,2,3,4,& 5 MEDIUM BACK IN MESH BLACK COLOR WITH FIXED ARMREST , SINGLE POINT SYNCHRO 1 MECHANISM, CLASS 4 GASLIFT, NYLON BASE WITH NYLON CASTOR WITH FABRIC UPHOLSTERED SEAT AND MESH BACK All Dim in MM with open tolerance of +/- 10mm and ANSI / BIFMA/X5.1 compliant chair (The description has been described fully at Sr. No.21 at page no.38-39 of DNIT)

111

-

-

... More
CHAIRS: FOR STORE KEEPER, RECORD KEEPER, STENO/ SECURITY/DAIRY DISPATCH STENO CHAIRS : MID BACK IN BLACK MESH WITH FIXED ARMREST , SINGLE POINT SYNCHRO MECHANISM, CLASS 4 GAS LIFT, NYLON BASE, NYLON CASTOR WITH FABRIC UPHOLSTERED SEAT All Dim in MM with open tolerance of +/- 10mm and ANSI / BIFMA/X5.1 compliant chair BACKREST : The back shall be made up of 12mm Dia MS rod and upholstered with Mesh fabric. The back frame shall be designed with contoured lumber support for achieving comfortable seating posture. Back rest size - Medium Back (MB) 655mm (H) X 485mm (W). The backrest tested for 1,20,000 cycles to be completed with a load of 44.5Kg as per ANSI / BIFMA X5.1. (The description has been described fully at Sr. No.22 at page no.39 of DNIT)

66

-

-

... More
CONFERENCE TABLE : -32 SEATER IN OVAL SHAPE Senater Conference table 32 seater - Senate Conference Table With Wire Manager size shall be Single seater 760 Width mm x 600 Depth mm , Two seater 1360 Width mm x 600 Depth mm , Half Round (2 Seater ) R 713 + Quarter Round ( 1 Seater ) R 713. The top shall be 31.6 mm thick (18 mm + 12 mm + 0.6 mm DL ( both sides ) + 0.4 mm Membrane ) Edge Profile shall be waterfall edge 10 mm radius on top edge and 5 mm at bottom. In Understructure the Legs shall be made from 25 mm PPB having a straight profile with half round edges and clad with 0.6 mm thick post Forming laminate. Overall thickness of leg shall be 26.2 mm The modesty panel in understructure shall be mae from PLT ( Pre laminated twin) boards of 18 mm thick. There shall be Wire Management wire carrier shall be made from 0.6 mm thick CRCA painted and carrier cover shall be made of 12 mm thick MDF painted all over.

1

-

-

... More
OPEN OFFICE LINEAR WORKSTATIONS 1200(L)X600(D) Linea workstation 1050 * 600 cpu trully - DESK BASED SYSTEMS -LINEA 1. LEG ASSEMBLY 1.1 MAIN LEG ASSEMBLY/ MAIN LEG DOUBLE ASSEMBLY 1.2 SHARED LEG ASSEMBLY/SHARED LEG DOUBLE ASSEMBLY 1.3 CABLE RISER LEG ASSEMBLY 1.4 SINGLE LEG ASSEMBLY 1.5 END LEG ASSEMBLY 2. CROSS CONNECTORS (The description has been described fully at Sr. No.24 at page no.40 - 44 of DNIT)

52

-

-

... More
OPEN OFFICE FOR CCP (NCR ) STAFF W/S LINEAR+ CURVILINEAR WORKSTATIONS 1500(L1)X1500(L2)X600(D)X740(H) WITH MOBILE PRELAM PED UNIT B+F (The description has been described fully at Sr. No.25 at page no.45 - 48 of DNIT)

10

-

-

... More
VISITOR'S CHAIR FOR PA OF DIRECTOR'S+CTP+ CTP IT&M, COMMISSONER &CCPNCR & PMIT, DEP. IT, ATP 1,2,3,4& 5, ROOM, JE, PLANNING ASST., JUNIOR DM 1,2,3,4,& 5, KANUNGO, SUPD, DA, ADA, SO, AO, STORE KEEPER, RECORD KEEPER, STENO / SECURITY / DIARY DISPATCH - MID BACK CHAIR WITHOUT ARMREST WITH FABRIC UPHOLSTERED SEAT AND BACK Motion Mid back chair - The cushioned seat assembly consists of seat base moulded in glass-filled Poly-amide, moulded Polyurethane foam & upholstered with high stretch knitted polyester fabric. The cushioned back assembly consists of back inner moulded in Polypropylene in-situ moulded with Polyurethane foam &upholstered with high stretch knitted polyester fabric.

91

-

-

... More
CATEGORY B - SOFA 3 SEATER- 2065(W)X850(D)X760(H) SOFA- 3 SEATER All Dim in MM with open tolerance of +/- 10mm Three seater Sofa: Providing and installing as per layout plan three seater sofa with SIZE : 2065(W) X 850(D) X 760(H). Inner solid Frame structure shall be made of high quality tropical Meranti wood. The wood shall be kiln chemical treated tropical Meranti wood. The legs shall be made of rubberwood having melamine matt finshall beh. The seat cushion shall be made of 7 inches multi layered foam of density 32D 23D 32D and HD with polyester polyfill outer layer of 180 gsm. The polyester polyfill keeps the upholstery wrinke free and soft. The seating cushions have 3 inches of elastic webbing of 350 gsm with diagonal weave. The thread used shall be nylon bonded to provide lasting stitch strength. (The description has been described fully at Sr. No.27 at page no.49 of DNIT)

8

-

-

... More
CATEGORY B - SOFA 2 SEATER- 1525(W)X850(D)X760(H) SOFA- 2 SEATER All Dim in MM with open tolerance of +/- 10mm Three seater Sofa: Providing and installing as per layout plan three seater sofa with SIZE : 1525(W) X 850(D) X 760(H). Inner solid Frame structure shall be made of high quality tropical Meranti wood. The wood shall be kiln chemical treated tropical Meranti wood. (The description has been described fully at Sr. No.28 at page no.49 of DNIT)

7

-

-

... More
CATEGORY B - SOFA 1 SEATER- 990(W)X850(D)X760(H) SOFA- 1 SEATER All Dim in MM with open tolerance of +/- 10mm Three seater Sofa: Providing and installing as per layout plan three seater sofa with SIZE : 990(W) X 850(D) X 760(H). Inner solid Frame structure shall be made of high quality tropical Meranti wood. The wood shall be kiln chemical treated tropical Meranti wood. The legs shall be made of rubberwood having melamine matt finshall beh. The seat cushion shall be made of 7 inches multi layered foam of density 32D 23D 32D and HD with polyester polyfill outer layer of 180 gsm. The polyester polyfill keeps the upholstery wrinke free and soft. The seating cushions have 3 inches of elastic webbing of 350 gsm with diagonal weave. The thread used shall be nylon bonded to provide lasting stitch strength. (The description has been described fully at Sr. No.29 at page no.49-50 of DNIT)

3

-

-

... More
CAFÉ TABLE A) Time Out 4 Seater PU Coated - 1135 x 1175 x 750 Time Out 4 Seater PU Coated size shall be 1135 Width mm x 1175 Depth mm x 750 Height mm . Top shall be 25 mm thick base material shall be 25 mm MDF board. On top PU painting of minimum 2H hardness with 75% glass as per color chart.Combination color graphics on the centre. Brown Laminate on bottom specially profiled edges for comfort. The Understructure shall be having bend pipe structure of MS powder coated. Pipe dia 38 mm , 2 mm thick and it shall be fitted with top by SS machine screws. Legs shall be of MS powder coated and 38 mm dia. pipe legs are fixed with inderstructure and table top. Glide shall be of Plastic fixed at the understructure to prevent the damage of table top during stacking.

3

-

-

... More
B) Time Out 6 Seater PU Coated - 1734 x 1175 x 750 Time Out 6 Seater PU Coated size shall be 1734 Width mm x 1175 Depth mm x 750 Height mm . Top shall be 25 mm thick base material shall be 25 mm MDF board. On top PU painting of minimum 2H hardness with 75% glass as per color chart.Combination color graphics on the centre. Brown Laminate on bottom specially profiled edges for comfort. The Understructure shall be having bend pipe structure of MS powder coated. Pipe dia 38 mm , 2 mm thick and it shall be fitted with top by SS machine screws. Legs shall be of MS powder coated and 38 mm dia. pipe legs are fixed with inderstructure and table top. Glide shall be of Plastic fixed at the understructure to prevent the damage of table top during stacking.

5

-

-

... More
Unwind chair - The seat and back are made up of injection moulded high impact strength polypropylene polymer with indoor gate UV resistance. The dimensions of Back shall be 51.6cm. (W) X 40.5cm. (H) and of seat shall be 52.5cm. (W) X 53.2cm. (D). The Tubular welded frame is made of made of 3.5±0.03cm x 1.5±0.03cm x 0.12±0.0128cm thk M.S. E.R.W. tube and welded connecting tube made of dia 2.22±0.03cm x 0.12±0.0128cm thk stainless steel 202 grade tube. The tubes are buff polished to give shiny finish. The shoes are made of high impact strength polypropylene polymer compound with indoor grade UV resistance and pressed fitted with tubular frame.

42

-

-

... More
LIBRARY RACK- OPEN SINGLE SIDED WOOD & STEEL BOOK RACK BASE UNIT 1890Hx900Wx300D -Overall Dimensions of Double Sided Wood & Steel Book Rack Base Unit shall be 900mm(W)x590mm(D)x1890mm(H). Rigid Knockdown construction . Back panel up to the bottom of third rack for additional rigidity . Racks, Back panel & Skirting : CRCA 0.8 mm thickness . Side panels : 25 mm thick pre laminated particle board (PLB) with laminate on both sides . Stackability shall have add-on units width wise to form a bank of racks having common side panel . Bottom plus four fixed racks plus 10 storage levels. Each rack is provided with stiffener at bottom for strength . Uniformly distributed load capacity per each full shelf is 80 Kg maximum . Rack back stiffener shall be there at the rear side of the racks back stiffener s are provided . These are to support books on the rear side . Label Holder on each main unit to insert labels for identification . Finish shall be Epoxy polyester powder coated to the thickness of 50 microns .

9

-

-

... More
OPEN SHELF- STRORAGE UNIT - 1000(L)X375)D)X1050(H) All Dim in MM with open tolerance of +/- 10mm Single module open storage unit o/s 1000LX375DX1050H The side, top and back panels are made of 18mm thick prelam particle board with lamination on both sides. The prelam particle board is mounted on the basic frame structure made out of 2" X 1" thick CRCA pipe confirming to IS 513:2008. The shelves are made up of 25mm thick Prelam Particle board with same lamination on both sides. The top corners are covered with aesthetically extruded aluminium giving a complete smooth finish to the structure confirming to IS 733. The bottom three shelves of each unit are at various angles to enable quick location of books / references. The bottom most shelf is inclined at 15 degree, the 2nd lst shelf is inclined at an angle of 9 degree and the 3rd last shelf are inclined at an angle of 3 degree. The shelves are suitable for books & files of different heights. The lower 2 shelves are of 280mm height suitable for larger size files/ books. (The description has been described fully at Sr. No.33 at page no.51 of DNIT)

50

-

-

... More
BOOK SHELF - STROAGE UNIT - 900(L)X375)D)X1860(H) All Dim in MM with open tolerance of +/- 10mm Single module open storage unit o/s 1000LX375DX1860H The side, top and back panels are made of 18mm thick prelam particle board with lamination on both sides. The prelam particle board is mounted on the basic frame structure made out of 2" X 1" thick CRCA pipe confirming to IS 513:2008. The shelves are made up of 25mm thick Prelam Particle board with same lamination on both sides. (The description has been described fully at Sr. No.34 at page no.51 of DNIT)

101

-

-

... More
OFFICE BOY SEATING - METAL PERFORATE BENCH -3 SATER WITH ARMS AT END Providing and fixing waiting area seating in lobby area as per layout, as 3 seater of SIZE:- 1765(L)X710(D)X775(H) Considering seat, arms and legs shall be made of High quality cold-rolled steelof thickness 1.2 mm which is perforated, presseed and welded to form the required shape Centre Beam shall be Made of High quality cold-rolled stee lof thickness 2 mm, and surface is treated to avoid rusting, seat is made of 1.2 mm thick cold-rolled steel and duly powder coated, Arms & Legs shall be made of 1.2 mm thick cold-rolled steel and duly powder coated.

16

-

-

... More
FREE STANDING PARTITION WITH STABILITY POST- MINIMUM 60 MM THICK -1200 MM HT 60MM THICK PARTITION, 1200 MM HEIGHT WITH STABILITY POST AS PER LAYOUT All Dim in MM with open tolerance of +/- 10mm (The description has been described fully at Sr. No.36 at page no.51-52 of DNIT)

865

-

-

... More
CATEGORY B - GREET CHAIR - The seat-back shell is made of 15mm Plywood (As per IS:303) panels connected using Brackets made from 3mm Hot Rolled Steel Plates (HR) (As per IS:2062). The Steel Brackets are Epoxy Polyester Powder Coated (DFT 40-60 microns). 25mm PU slab-stock foam is pasted onto both sides of the shell and picnhed together to achieve the radius along the periphery. It is upholstered in Leatherette (The description has been described fully at Sr. No.37 at page no.52 of DNIT)

4

-

-

... More
TETRIS FIXED - The seat is made up of synthetic leather upholstered on PU slabstock foam of 6.5 cm (±0.5 cm). It is which is fitted to the upholstered wooden batten box by bolting from the inside. * SEAT SIZE : 42.0 cm. (W) x 42.0 cm. (D) CASING OF TETRIS:

9

-

-

... More
IMMERSE WORKPOD - The base-top is made using 18mm Plywood (As per IS:303), and Natural Veneer pasted onto 4mm backing Plywood. The base-top has a bidding of FSC-certified seasoned Teak-Wood finished with a clear matt coat of PU lacquer around the periphery. The base Under-structure consists of Legs and Cross-members made with FSC-certified seasoned Teak-Wood . They are connected using Epoxy Resin Based Adhesive and finished with a Clear Matt Coat of PU lacquer. The Under-structure and top is assembled using alloy steel hardware (blackened & coated with rust preventive oil). 2. BACK-FRAME The Back-frame has an Under-structure made of 18mm Plywood (As per IS:303). It is covered with 06mm Plywood (As per IS:303) from the inside.

1

-

-

... More
IMMERSE WORKPOD - The base-top is made using 18mm Plywood (As per IS:303), and Natural Veneer pasted onto 4mm backing Plywood. The base-top has a bidding of FSC-certified seasoned Teak-Wood finished with a clear matt coat of PU lacquer around the periphery. The base Under-structure consists of Legs and Cross-members made with FSC-certified seasoned Teak-Wood . They are connected using Epoxy Resin Based Adhesive and finished with a Clear Matt Coat of PU lacquer. The Under-structure and top is assembled using alloy steel hardware (blackened & coated with rust preventive oil). 2. BACK-FRAME The Back-frame has an Under-structure made of 18mm Plywood (As per IS:303). It is covered with 06mm Plywood (As per IS:303) from the inside.

5

-

-

... More
ORBB POUFFE - The inner structure is made with a combination of 18mm thk Plywood (As per IS:303) & Pine-Wood members. It is covered from the sides using 2mm kraft-board. Complete understructure is made by gluing, nailing & stapling. Seat is made of 100 mm PU Slab-stock Foam pasted on top of this structure. The understructure is covered with a layer of 12mm PU Slab-stock Foam around the sides. The structure is upholstered with Leatherette on the sides, and a combination of Mesh Fabric & Leatherette on the top.

3

-

-

... More
ORBB SEAT - The structure consists of Top & Bottom Ring made of 025.4 x 1.6thk Round Electric Resistance Welded Tubes (ERW), and connected by Vertical Members made of 019 x 1.6thk Round Electric Resistance Welded Tubes (ERW). The Understructure is welded together using Tungsten Inert Gas (TIG) Welding. The whole structure is Epoxy Polyester Powder Coated (DFT 40-60 microns). The Frame rests on a base made of 18mm thk Plywood (As per IS:303) . The Seat Base is also made of the same. Both are fixed with the understructure using welded Brackets made of 3mm thk Hot Rolled Steel Plates (HR) (As per IS:2062). It is assembled using alloy steel hardware (blackened & coated with rust (The description has been described fully at Sr. No.37 at page no.54 of DNIT)

3

-

-

... More
COMPACTORS A) SD4-Single Static Drive Cover Unit 4 Bay

1

-

-

... More
B) LD4-Single Last Drive Unit 4 Bay

1

-

-

... More
C) TD4-Twin Mobile Drive Unit 4 Bay

1

-

-

... More
J) SD5-Single Static Drive Cover Unit 5 Bay

1

-

-

... More
K) LD5-Single Last Drive Unit 5 Bay

1

-

-

... More
L) TD5-Twin Mobile Drive Unit 5 Bay

1

-

-

... More
K) Rail 9' (The description has been described fully at Sr. No.38 at page no.54-58 of DNIT)

2

-

-

... More
CAFÉ HIGH STOOLS

4

-

-

... More
CHAPTER 'B' FALSE CEILING Providing and fixing false ceiling at all height including providing and fixing of framework made of special sections, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25mm x 1.6mm thick with flanges of 27mm and 37mm , at 1200mm centre to centre,one flange fixed to the ceiling with dash (The description has been described fully at Sr. No.1.1 at page no.59 of DNIT)

49

-

-

... More
GYPSUM CEILING Providing and fixing india gypsum/ lafarge make 12.5mm thick gypboard ceiling surfaces in plain including G.I. suspenders forming a grid of intermediate channel at 1220mm centre to centre with ceiling sections fixed at 450mm centre to cemtre at right angle to the underside of intermediate channels with connecting clips complete as per India Gypsum/Lafarge Technical Manual including using corner profiles, finishing with jointing compound and joint paper tapes and priming with two coats of drywall top coat and fixing of perimeter channel at both ends. (The description has been described fully at Sr. No.1.2 at page no.59 of DNIT)

591

-

-

... More
Conference room ceiling Providing and Fixing Armstrong/ Himalayan Acoustics/ Ecophone SoundScapes - Acoustical clouds which are 30 mm thick, flat glass fiber panels with Humidity Resistance RH 90% & Recycled Content of minimum 30%, come in Hexagonal shape of 1.1 x1.1 m in the color specified by the Architect / Engineer in charge (Ivory / Pale Green / Pastel Blue / Traffic Grey / Pale Brown). (The description has been described fully at Sr. No.1.3 at page no.60 of DNIT)

51

-

-

... More
WOOD PARTITIONS Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-01 partition GP1)

76

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-02 partition GP2)

114

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in this item. (refer drg no AR-04 partition GP4)

74

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-05 partition GP5)

133

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-07 partition GP7)

132

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-08 partition GP8)

40

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-10 partition GP10)

147

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-13 partition FP3)

20

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-14 partition FP4)

308

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-15 partition FP5)

156

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-17 partition FP6)

124

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-36 partition FP7)

135

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-18 partition SP1(A)

73

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-19 partition SP2(A)

115

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-20 partition SP3(A)

19

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-21 partition SP4)

245

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-22 partition SP5)

181

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-23 partition SP6)

21

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-26 partition SP8)

26

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-25 partition SP9)

107

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-27 partition TP1)

37

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-28 partition TP2)

89

-

-

... More
Providing and fixing both side plywood Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick marine ply of century/ kitply/ Greenply on both sides with 1mm thk laminate pasted on both sides. The horizontal & vertical joints of the plyboards on both sides of the metal framework must be staggered so as to avoid through and through joints. The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also also include fixing of 6mm thick grade 1 exterior MDF board to be installed on the exposed vertical edge of the partition for a total width with same 1mm laminate pasted on it. The measurement of this shall be in SQ. FT.. of partition area only inclusive of MDF edge & ply board fixed on both sides, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in his item. (refer drg no AR-29 partition TP3)

153

-

-

... More
GLASS PARTITION Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. (refer drg no AR-02 partition GP2)

80

-

-

... More
Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. (refer drg no AR-05 partition GP5)

64

-

-

... More
Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. (refer drg no AR-06 partition GP6)

63

-

-

... More
Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. (refer drg no AR-07 partition GP7)

63

-

-

... More
Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. (refer drg no AR-11 partition FP1)

45

-

-

... More
Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. (refer drg no AR-12 partition FP2)

48

-

-

... More
Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. (refer drg no AR-13 partition FP3)

72

-

-

... More
Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. V (refer drg no AR-14 partition FP4)

71

-

-

... More
Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. (refer drg no AR-16 partition FP5A)

258

-

-

... More
Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. (refer drg no AR-18 partition SP1A)

84

-

-

... More
Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. (refer drg no AR-19 partition SP2A)

61

-

-

... More
Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. (refer drg no AR-20 partition SP3)

118

-

-

... More
Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. (refer drg no AR-24 partition SP7)

97

-

-

... More
Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. (refer drg no AR-25 partition SP8)

280

-

-

... More
Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. (refer drg no AR-26 partition SP9)

48

-

-

... More
Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. (refer drg no AR-27 partition TP1)

280

-

-

... More
Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. (refer drg no AR-28 partition TP2)

46

-

-

... More
Providing and fixing full height partition with 12 mm thk toughened clear glass as per detailed drg. the glass to be held in place using using WCP profile with SS finish cover plate on both sides at top and bottom, including the etching film pattern as shown in detailed drgs. Glass to glass joint to be as per detailed drgs . glass work to be executed by a dorma/ D-line/Stanley /Yale authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drg and decision of engineer in charge. Payment shall be made only for visible glass area excluding fins etc if any. (refer drg no AR-29 partition TP3)

46

-

-

... More
GLASS DOOR Providing & fixing 10 mm thick toughened glass doors on dorma/yale/Dline patch fittings consiting of Top pivot (PT24), top patch (PT20), Bottom Patch (PT10), Overpanel/sidepanel connector with pivot (PT40), Overpanel /sidepanel connector with/ without pivot (PT60), center lock (US10) and double action floor spring with variable EN force(BTS75v ) with Studio Classic Lock with euro cylinder one side key & one side thumb turn. glass work to be executed by a dorma/ D-line/ authorised system integrator only. All patch fittings,door closers etc shall carry a company warranty of 3 years on a company letter head. The rates quoted should include the cost of glass,etching of glass, toughening, cutting of glass as per site, installation of doors, any support systems required etc complete in all respects as per detail drawing.

461

-

-

... More
WALL PANELLING WITH VENEER Providing and fixing one side panelling of WPC board & 4mm plywood veneer Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick WPC board of century/BVW/ biowood on one side. The horizontal & vertical joints of the WPC boards on the metal framework must be staggered. Pasting & nailing of 4mm thk plywood veneer of Greenply/ century/ Merino csoting Rs 100 per sft (additional or lower rates shall be payable/deductable) . The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also include GI farmework, WPC boards, all labour etc., fixing of veneer ply, polishing in matt melamine water based polish or high gloss water based polish as required by architect complete in all respects as per design. The measurement of this shall be in SQ. M. of partition area only inclusive of edge, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in this item.

720

-

-

... More
Providing and fixing one side panelling of WPC board & 4mm plywood veneer and bronze reflective mirror with beading (design as per drg) Drywall partition using India Gypsum/USG Boral floor and Ceiling channel (0.55 mm thick, 50mm wide & having two flanges of 30mm each) to the RCC Floor and Slab/ support structure with Approved Fasteners @ 600 mm Centers respectively. Wall Studs are minimum 0.55 mm thick and Wall studs are placed at 610 mm centers in Floor and Ceiling channel. The partition shall be fixed with 12mm thick WPC board of century/BVW/ biowood on one side. The horizontal & vertical joints of the WPC boards on the metal framework must be staggered. Pasting & nailing of 4mm thk plywood veneer of Greenply/ century/ Merino csoting Rs 100 per sft (additional or lower rates shall be payable/deductable) . The rates quoted are inclusive of scaffolding, fastneres, cutting of board for electrical points/ conduits etc. The rates also include GI farmework, WPC boards, all labour etc., fixing of veneer ply, polishing in matt melamine water based polish or high gloss water based polish as required by architect complete in all respects as per design. The measurement of this shall be in SQ. M. of partition area only inclusive of edge, only area of partition in elevation shall be payable any extra support or GI section shall not be payable in this item. (Refer drg. no. AR-35)

416

-

-

... More
CONFERENCE WALL PANELLING Providing and fixing of Armstrong/ Himalayan acoustics/ ecophone make Acoustical Wall Paneling’ with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class B-s1, d1 as per EN13501, fabric with an option of colors, as per the choice of the Architect of size 600X600 mm providing a minimum sound absorption level of 0.90 NRC to be affixed to wall using Wall panel impalers supplied by OEM and construction adhesives as per the instructions laid down by the manufacturer. 3 Nos.wall panel Impalers shall be fixed to the wall surface using self tapping screws. Silica based construction adhesive to be dabbed on to the projecting elements (spikes) of the impalers. wall panels shall be pierced through the spikes of the impalers ensuring the line and level of the panels are maintained. Installation to be carried out by OEM Trained Installation team & Installation should be carried out as per OEM recommended procedure complete in all respects

1302

-

-

... More
PAINT Providing and fixing textured paint of Oikos/Ultratech in desired finish costing Rs 80/sqft (additional or lower rates shall be payable/deductable).

63

-

-

... More
STRIP LIGHT Providing and fixing Wipro/ philips/ Svarochhi make LED Strip Lights of 8W per rmt colour changeable for 2700 - 6500K & rgb including cutting to desired size as required, wiring for intreconnecting strips, drivers for running the the strip lights, the strip shall be self adhesive type in desired colour as required. the rates quoted are inclusive if fixing in postion as required as per detailed drgs.

247

-

-

... More
MIRROR Providing & fixing in position 6mm thick St Gobain clear mirror mounted on 12 mm thk marine ply of century/ kitply/ Greenply using structural silicone as per detailed drg. The rates quoted are inclusive of 50x75mm aluminium sub frame to be fastened to the wall & making of cove around mirror using 12mm thk marine ply including pasting og 1mm white laminate as per CI, fixing of edge moulding of 45x12 U profile in SS sheet of 1mm thickness all around the mirror as per detailed drgs. The rates quoted are inclusive of making all the coves, niches, SS edge beading , laminate , fixing with glue, aluminium frame etc,, including cutting of holes, boxes, etc complete in all respects. The measurement for payment shall be made in Sq. ft for only the visible mirror area , no payments shall be made for any support structure of any material.

12

-

-

... More
DIGITAL PRINTED MAP FOR RECEPTION BACKDROP Providing and fixing reception backdrop wall with self sticking PVC flex with high resolution digital printing pasted on 12mm thk glass fixed on wall as per detailed drg using SS studs as per detailed drgs. the rates quoted are inclusive of scaffolding, glass, ss studs, digital printed flex, pasting and fixing in position complete in all respects.

105

-

-

... More
Vertical garden for reception and waiting area Providing and fixing interior vertical garden as per drgs including fixing of natural stone tiles on wall face (cost of tiles Rs 150 per sft) including making of vertical garden complete with plants, stands, pots etc complete in all respects as per design given. The ratesquoted are inclusive of waterproofing of walls, making of niches, mortar/ tiles adhesive etc, labour scaffolding etc complete in all respects to give the desired look and finish. a) Fixing of wall natural stone tiles (tiles basic rates including taxes etc Rs 150per sft)

375

-

-

... More
b) Fixing of vertical garden plants including SS contatiners, fixing system, watering system to ba all concealed with plants as chosen by by the architect complete in all respects as per drgs.

50

-

-

... More
CONCEALED LIGHTS Providing and fixing Wipro/ philips/ Svarochhi make down lighter Lights of 8W per rmt colour changeable for 2700 - 6500K & rgb including cutting to desired size as required, wiring and switches for intreconnecting strips, drivers for running the lights, the rates quoted are inclusive if fixing in postion as required as per detailed drgs. 8 Watt Downlighter

9

-

-

... More
12 Watt Downlighter

6

-

-

... More
CARPET TILES Providing and laying Modular Carpet Of Welspun Global Brands Ltd. / Milliken Global Express Series Relay Volume II,/ Nature Volume III/ Urbane Volume II or equivalent, Nylon 6 Tufted Textured Loop Pile, manufactured using Digital Injection Dyeing Process, solution dyed nylon tiles of size 50 cms x 50 cms with Anti Microbial Alphasan, Cushion backing , Stiches/Rows 14.4/ inch, Guage 1/10 (39.4/10 cm), Nominal total thickness 6mm.), flammability = 0.45 (class1) including fixing with Adhesive and fixing of door profile protections at doors complete in all respects as per drawing and directions of Engineer-In-Charge.

1142

-

-

... More
FLOORING Providing and laying Stone Polymer Composite of Welspun Global Brands Limited Series Luxury Performance Tiles or equivalent, waterproof, termite proof, fire resistant, scratch resistant, having sizes 9"x48" regular emboss/ deep emboss ( micro bevel / painted bevel) manufactured using Limestone & polymers having thickness of 4 mm. with a wear layer of 0.3mm to 0.5 mm. with protective treatment of UV Layer & Stain resistant, with Anti Microbial, LEED Environmentally preferable with uniclick/ tongue & groove interlock including installation with the help of profiles like Skirting/ quarter round, reducer/ T-moulding, protections all along of steps & corners complete as per drawing and directions of Engineer-In-Charge.

2580

-

-

... More
WALL PAPER Providing and fixing in position wallpaper of desired colour shade & texture ( baseprice rs 100 /sft all incusive) to be pasted in place at desired location on walls/ partitions/ ceiling etc such that joints are not visible complete in all respects including, glue, cutting, wastage etc .

2974

-

-

... More
HANGING LIGHT for Director Room/ conference Providing and fixing in location LED linear lights in desired shape of recatngle & hexagon of wipro/regent/ philips make to give a seamless finish with no endpoints/junction being visible in the light. The fixture shall be approx 600mm/ 1200mm long of approx 40w per rft shall be ceiling suspended using sliding fixing wire system and having diffuser for uniform light distribution.the rates quoted are inclusive of all fixing and cutting to desired shape and size s required at site.

87

-

-

... More
LACQUERED GLASS Providing and fixing in various locations as scribbling boards 6mm thick lacquered glass of Saint Gobain make in various colours in desired patterns pasted on 8mm MDF board of greenply/ nuwud/ asic make pasted using silicon sealant of 995 grade dow corning / alstone/ GE in similar colour as glass, mounted on wall using 25 mm Stainless steel 304 grade studs fixed to walls flush with no gap between wall and ply with studs installed on all 4 corners of glass of smaller sizes upto 600 mm wide & additional studs fixed at every 1000 mm at top & bottom for larger sizes. the glass shall be bevelled on the perimeter all around for a distance of 25 mm. the rates quoted are complete in all respects including fixing of studs, rawl plug, holes in glass bevelling etc complete in all respects.

373

-

-

... More
CHAPTER 'C' SMART TV with SKYPE calling enabled Supply installation testing & commisioning of 55" size LED panel of Samsng/ LG/ Sony make with minimum 1920X1080 pixels resolution. The display should have Brightness of 350 nits and Contrast Ratio of minimum 5000:1. The display should have minimum 1X VGA, 1X DVI, 3X HDMI, 1X USB Inputs and RS 232X1, RJ 45X1 & Audio X1 Output. The display should be Smart type with installable apps, Speakers and have option of firmware update over network. The display is to be supplied with media player or PC stick to enable installation of skype calling including the cost of Skype enabled camera of 4 megapixels with minimum one HDMI 1.4 input connector minimum 2 USB ports, 32 GB storage, Pre installed WIn 10 32 bit or better.

3

-

-

... More
Supply installation testing & commisioning of 65" size LED panel of Samsng/ LG/ Sony make with minimum 1920X1080 pixels resolution. The display should have Brightness of 350 nits and Contrast Ratio of minimum 5000:1. The display should have minimum 1X VGA, 1X DVI, 3X HDMI, 1X USB Inputs and RS 232X1, RJ 45X1 & Audio X1 Output. The display should be Smart type with installable apps, Speakers and have option of firmware update over network.

4

-

-

... More
VIDEO WALL (10'X6') Providing and fixing video wall of Samsung/ LG make at desired location of size approx. 10'x6' with bezel size of maximum 1.8 mm with provisoning of HDMI-1,DVI-D-1,Display Port(DP)-1, OPS-1,RS232C-1, RJ-45 -1, RGB, USB ports, minimum 8GB storage and 3 years warranty, complete with all these sockets being transfereed to the main table/ desired location by extension cable and female sockets for input from the table to all these ports. the rates quoted are for complete installation and working of the video wall as desired including cost of matrix switcher with 9 inputs and controller to be able to switch between any diferent display on any screen or single or mutiple screen display and the female sockets on table. the item shall be payable in sq ft of the installed video wall area

1

-

-

... More
CONFERENCE AUDIO SYSTEM SITC of fully digital wired Chairman unit , unit should be a fully integrated Chairman panel equipped, should have clear button for deactivate all the microphone headphone connector and headphone volume control, that included gooseneck microphone should be free from interference caused by mobile phones. It should combine several functionalities in one single panel. Gooseneck microphone with GSM immunity and LED ring , ,Microphone on/off button , RJ 45 or D9 or 6 Pole connector connectors for separate loop through cabling, Microphone length should not be less than 450 mm,3.5 mm jack socket for headphone, microphone should be programmed to track the camera during video conferencing etc. as reqd. Approved Make Bosch /Brahler/Beyerdynamic

1

-

-

... More
SITC of fully digital wired delegate unit , unit should be a fully integrated delegate panel equipped , headphone connector and headphone volume control, that included gooseneck microphone should be free from interference caused by mobile phones. It should combine several functionalities in one single panel. Gooseneck microphone with GSM immunity and LED ring , ,Microphone on/off button , RJ 45 or D9 or 6 Pole connector connectors for separate loop through cabling, Microphone length should not be less than 450 mm,3.5 mm jack socket for headphone, microphone should be programmed to track the camera during video conferencing etc. as reqd. Approved Make Bosch /Brahler/Beyerdynamic

16

-

-

... More
SITC of digital Central control unit should have the following features, the central unit for powering, configuring and Controlling connected Chairman, Delegate units, and option to control up to 50 units . The system should have in built digital processing and control/ transmission of the Digital audio signals. It should have basic management facilities with at least 4 open microphones should have recording facility SD/USB/External.Approved Make Bosch /Brahler/Beyerdynamic

1

-

-

... More
SITC of Interconnecting Cables. Approved Make Bosch /Brahler/Beyerdynamic

1

-

-

... More
SITC of Wireless UHF Handheld Microphone with frequency range of 50 Hz – 18 kHz and bandwidth support of 24 MHz or higher. The Mic should have S/N Ratio 106 dB or better. The handheld unit shall have Max. SPL of 140 dB and should be operated by 2 × AA batteries wirth minimum Operating Time of 12 hours. The transmitter should have minimum 30mW or more RF Power.Approved Makes: Mipro , Beyerdynamic, Sennheisser

4

-

-

... More
SITC of Premium 12-Input 2-Bus Mixer with Mic Preamps, British EQs and Multi-FX Processor. Approved Makes: Yamaha, Music Tribe, Allen & Heath.

1

-

-

... More
SITC of Speaker with 4 or better woofer and 1" or better tweeter with 50 W RMS Power. The frequency response should be 80-20000 Hz The max SPL of speaker should be 104 dB or above. Approved Makes: JBL, Apart, QSC.

6

-

-

... More
SITC of Dual Channel Digital Power amplifier, 2 x 150Wattss @ 4Ohms, 2 X 80Wattss @ 8Ohms, bridgeable to 1X 300Watts @ 8 Ohm Class D, Convection cooled. Approved Makes: JBL, Apart, QSC.

1

-

-

... More
SITC of all Audio Cables, Speaker Cables etc. Approved Makes: Kramer, Extron, Belden.

1

-

-

... More
SITC of 12 U Equipment Rack. Approved Makes: WQ, Valrack, APW President.

1

-

-

... More
Conference video system SITC of LCD Projector with minimum 1024*768 (XGA) Pixels Resolution and 6000 ANSI Lumens or better. The projector must have HDMIX1, D Sub 15 Pin X1 Inputs, Display Port X1, DVI-D. The projector should have contrast ratio of minimum 5000:1. Approved Makes: Panasonic, Barco, Christie.

1

-

-

... More
SITC of Ceiling Mount Kit for above projector.

1

-

-

... More
SITC of Motorized Screen of Matt White Fabric Size 9X12 Feet 4:3 Aspect Ratio with remote. Approved Makes: Draper, Dalite, Milan.

1

-

-

... More
SITC of Pop up box with 1X HDMI Input, 1X Power Socket.Approved Make: Magnum, Kramer, Extron.

7

-

-

... More
SITC of 8X1 HDMI Switcher having max data rate of 6.75 Gbps (2.25 Gbps per graphic channel), resolution support upto UXGA. It should suport Deep Color, x.v.Color, Lip Sync, HDMI Uncompressed Audio Channels, Dolby TrueHD, DTS−HD, CEC, 3D Pass-Through, EDID Pass–through. Approved Makes: Kramer, Extron, Lightware.

1

-

-

... More
SITC of 1X8 HDMI Splitter having max data rate of 6.75 Gbps (2.25 Gbps per graphic channel). It should suport Deep Color, x.v.Color, Lip Sync, CEC, 3D Pass-Through, EDID Pass–through. Approved Makes: Kramer, Extron, Lightware.

1

-

-

... More
SITC of VGA HDMI Convertor.

7

-

-

... More
SITC of 20m HDMI Cables. Approved Makes: Kramer, nt, Extron.

13

-

-

... More
SITC of 12 U Equipment Rack. Approved Makes: WQ, Valrack, APW President.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.