Public Works Department Tender

... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date24 Dec 2022
Closing Date9 Jan 2023
Tender Amount₹ 17,35,432 
Notes
Download

Costs

  • EMD

    ₹ 34,709
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
HSR-Item: [23.1.6.1] Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm)

290

-

-

... More
HSR-Item: [23.1.6.3] Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required.1 run of Size 4 Sqmm(1/2.24mm)

210

-

-

... More
HSR-Item: [23.1.6.4] Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm)

180

-

-

... More
HSR-Item: [23.1.6.5] Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required.1 run of Size 10 Sqmm(1/3.50 mm)

195

-

-

... More
HSR-Item: [23.1.6.6] Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm)

85

-

-

... More
HSR-Item: [23.1.6.8] Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 2 run of Size 4 Sqmm(1/2.24mm)

90

-

-

... More
HSR-Item: [24.1.1] Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.

3

-

-

... More
HSR-Item: [24.1.2] Extra for using salt and char coal/coke for pipe earth electrode as required.

3

-

-

... More
HSR-Item: [24.1.3] Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal orv coke and salt) complete as required.

2

-

-

... More
HSR-Item: [24.1.5] Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode

2

-

-

... More
HSR-Item: [24.1.9] Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required

20

-

-

... More
HSR-Item: [24.1.11] Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required.

35

-

-

... More
HSR-Item: [24.1.14] EARTHING AND LIGHTENING ARRESTOR 14. Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. staples of same size.

35

-

-

... More
HSR-Item: [24.2.7.2] Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core.

8

-

-

... More
HSR-Item: [24.2.7.3]. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core

8

-

-

... More
HSR-Item: [23.5.1.2] [Through Rate] COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 1.2. Wiring only in 1.5 sqmm PVC insulated copper conductor cable for LIGHT/FAN/Call bell point in existing conduit pipe and MS boxes including cost of Bakelite cover for MS box, switch, wall socket, ceiling rose/connector etc. Group B

126

-

-

... More
HSR-Item: [23.5.4.2] Wiring in existing conduit and MS box for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch etc complete as required Group B

30

-

-

... More
HSR-Item: [23.5.5.2] Wiring in existing conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling, including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch etc complete as required Group B

30

-

-

... More
HSR-Item: [23.5.6.1] Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/ PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm)

800

-

-

... More
HSR-Item: [23.5.6.3] Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required 1 run of Size 4 Sqmm(1/2.24mm)

670

-

-

... More
HSR-Item: [23.5.6.4] Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm)

240

-

-

... More
HSR-Item: [23.5.6.5] Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm)

140

-

-

... More
HSR-Item: [23.5.6.6] Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm)

190

-

-

... More
HSR-Item: [23.5.6.8] Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 2 run of Size 4 Sqmm(1/2.24mm)

120

-

-

... More
HSR-Item: [24.4.5] Supply and erection of Single Phase weather proof M.S. box of size 20 cm x 15 cm x 10 cm with hinged cover made of 2 mm thick MS sheet, locking arrangements, housed in wall/fixed on pole , including the cost of 1 no 4 way 16 A Bakelite connector, 1 no. 6 amp SP MCB and 1 Nos. 16 amp. neutral links fixed on Bakelite sheet in the M.S. box including painting and necessary connections.

10

-

-

... More
HSR-Item: [24.4.8.5] Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 7 Metre Long pole with top dia 75 0mm and bottom dia 150 mm with base plate of size 300 x 300 x 20 mm.

8

-

-

... More
HSR-Item: [24.5.2.3] S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia.

240

-

-

... More
HSR-Item: [23.6.6.1] Supply and erection of MS conduit pipe 1.6 mm thick, ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-inCharge of work. MS Pipe of 20 mm dia.

490

-

-

... More
HSR-Item: [23.6.6.3] Supply and erection of MS conduit pipe 1.6 mm thick, ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-inCharge of work. MS pipe of 25 mm dia.

365

-

-

... More
HSR-Item: [23.8.1.1] Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Wall socket 5 amp on existing sheet.

35

-

-

... More
HSR-Item: [23.8.1.2] Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Switch 5 amp. on existing sheet.

35

-

-

... More
HSR-Item: [23.8.1.6] Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Call bell 220/230 volts musical type

9

-

-

... More
HSR-Item: [23.8.1.9] Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bell push

9

-

-

... More
HSR-Item: [23.8.1.12] Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size.

29

-

-

... More
HSR-Item: [23.8.1.13] Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Socket size rotary step type Electronic regulator for A.C. ceiling fan

53

-

-

... More
HSR-Item: [23.9] Erection of exhaust fan in existing opening, complete with necessary earthling of fan including carriage from PWD store to the site of work.

20

-

-

... More
HSR-Item: [23.22.1.3] Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA

1

-

-

... More
HSR-Item: [23.22.1.4] Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 125 to 160 Amp, 25 KA

2

-

-

... More
HSR-Item: [23.22.1.5] Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA

2

-

-

... More
HSR-Item: [23.22.1.12] Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA

1

-

-

... More
HSR-Item: [23.22.3.2] Supply and erection of sheet steel enclosures 1pole/2 pole/4 pole on wall/on existing pedestal complete as required. S.P.N. or DP enclosure suitable for DP MCB

11

-

-

... More
HSR-Item: [23.22.4.5] Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-inCharge of the work. TPN DB Horizontal type Double Door 4 way (8 incoming and 3phase*4 outgoing)

1

-

-

... More
HSR-Item: [23.22.4.7] Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-inCharge of the work. TPN DB Horizontal type Double Door 8 way (8 incoming 3phase*8 outgoing)

5

-

-

... More
HSR-Item: [23.22.4.9] Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-inCharge of the work. Vertical TPN DB Double Door 4 way ( 8 incoming and 3phase*4 outgoing)

2

-

-

... More
HSR-Item: [23.22.5.1] Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole

106

-

-

... More
HSR-Item: [23.22.5.6] Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCB's TRIPLE POLE

6

-

-

... More
HSR-Item: [23.22.5.8] Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCB's FOUR POLE

6

-

-

... More
HSR-Item: [23.23.1.3] MISCELLANEOUS 1.3. Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):- Size 25 mm dia

10

-

-

... More
HSR-Item: [23.24.1] Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide.

90

-

-

... More
HSR-Item: [23.24.4.1] Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 4 way 250 amp.

1

-

-

... More
NS Items:- Supply and erection of 25 W LED Post lantern new generation energy saving envirmental friendly long life aesthetically desinged with symmetrical light distribution, spen aluminium land scap luminiaries with high power LED as light source with the protection of IP-65 of LHEVBGP7PN 6K 025 (Rubby clear) of Havell's make/ BLPTSP 25 W NW LED of Bajaj/ Philips make complete with all accessories and labour to complete the job upto the entire satisfaction of Engineer-in-charge of the work.

2

-

-

... More
S/E of 60 W LED Street light fitting 110 Lumens per Watt Philips/ Havell's/ Wipro/ Bajaj make in aluminum pressure die casting housing toughened glass cover with IP-66 protection With Lense and dual surge protection device internal 5 KV and external 10 KV including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work.

8

-

-

... More
S/E of 60 W LED Flood light luminaries with high power LED 110 Lumens per Watt Philips/ Havell's/ Wipro/ Bajaj make in aluminum pressure die casting housing toughened glass cover with IP-66 protection With Lense and dual surge protection device internal 5 KV and external 10 KV including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work.

12

-

-

... More
NS Item: Supply & Erection of single arms bracket made of 32/50mm dia GI pipe B class ISI 1.20 mtr. Long with coller pipe (GI) 75mm dia 60cm Long top covered with ornamental cap duly welded, painted 2 coats of aluminium paints on bracket and golden paint of ornamental cap including the cost of labour and petty material etc. complete in all respect upto the entire satisfaction of Engineer-incharge. Bracket duly erected on existing 7/9 Mtr. High Octagonal pole.

8

-

-

... More
NS items: Suppy of exhaust fans of 12" (300 mm) approved make complete in all respect. Make:- Havell's/ Orient/ Crompton make.

9

-

-

... More
NS items: Supply and erection of AC Ceiling fan without regulator 48" (1200mm) ISI Certified complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Make:- Havell's Model Orion and equivallant make Orient/ Crompton/ Bajaj.

48

-

-

... More
NS items: Supply and erection of 40 W LED batten with aluminium base heat shink complete of Dura Batten 50000 Bussiness Hours, 4600 Lumens. complete with all accessories and labour to complete the job upto the entire satisfaction of Engineer-in-charge of the work. (Make:- Bajaj/ Havell's/ Philips/

50

-

-

... More
NS Items: S/E of 24 W indoor LED Tube fitting with batten and tube, decorative ultra slim liniare LED lighting fixture with extruded poly carbonate, environmental friendly, energy effiecent completed including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work. (Make:- Philips/ Havell's/ Bajaj)

35

-

-

... More
NS items: S/E of M.S. box for computer made of 16 guage of size 200mm x 200mm x 50 mm deep covered and 150 mm x 100 mm x 50 mm with white colour of ISI mark fixed by means of 4 nos .brass screws with cost of 1 No. 15 amp multi socket of ISI mark and 15 amp switch and 3 nos .5 amp multi socket with 5 amp switches of ISI mark including fixing the PVC gang box and to complete the job in all respect upto the entire satisfatoin of Engineer-in- Charge of the work.

15

-

-

... More
NS-Item: Supply of Under Ground LT Power Cables of Aluminium Conductor complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Make:- Havell`s/ KEI/ RR Kabel. 16 Sqmm 4 Core Ard. Cable

275

-

-

... More
10 Sqmm 2 Core Ard. Cable

240

-

-

... More
70 Sqmm 3.5 Core Ard. Cable

15

-

-

... More
50 Sqmm 3.5 Core Ard. Cable

15

-

-

... More
25 Sqmm 4 Core Ard. Cable

20

-

-

... More
HSR-Item: [24.2.2.2] LT CABLE 2.2. Laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.:- 16 Sq mm to 35 sqmm 2 to 4 Core

205

-

-

... More
HSR-Item: [24.2.2.3] LT CABLE 2.3. Laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.:- 50 Sq mm to 150 sqmm 2 to 4 Core

145

-

-

... More
HSR-Item: [24.2.7.4] LT CABLE 7.4. Supply and erection of suitable compression type brass cable glands for underground Cable :- 70 sqmm to 95 sqmm Cable 3 to 3½ Core

4

-

-

... More
Supply, erection and fixing of 12 mm thick ply wood board having a circular /rectangular hole etc as required including the cost of making hole, nuts and bolts, painting and other petty material with all labour etc. complete in all respect up to the entire satisfaction of Engineer-in-charge of the work.

20

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.