Public Works Department Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Public Works Department - PWD Tender

Works
Eprocure
Opening Date20 Dec 2021
Closing Date18 Jan 2022
Tender Amount₹ 1,56,57,12,093 
Notes
Download

Costs

  • EMD

    ₹ 2,79,78,000
  • Document Cost

    ₹ 50,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti termite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20%. (HSR 4.39).

20820.62

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: (HSR 6.1) (1) 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.1.1).

63.7

-

-

... More
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size). (HSR 6.1.2).

335.95

-

-

... More
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size). (HSR 6.1.6).

3758.55

-

-

... More
1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). (HSR 6.1.7)

409.54

-

-

... More
20 mm thick cement plaster damp-proof course 1:3 with 2 coats of bitumen at 1.65 kg. per sqm, laid hot and sanded: (1) Vertical. (HSR 6.12.1).

1169.65

-

-

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (HSR 6.13).

2649.48

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 330 kg/cum. Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is used as per design mix). (HSR 6.25). (1) All works up to plinth level. (HSR 6.25.1)

14025.09

-

-

... More
All works above plinth level up to floor IV level. (HSR 6.25.2)

23507.13

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work for: (HSR 6.29). Foundations, footings, bases for columns. (HSR 6.29.1)

100710.25

-

-

... More
Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. (HSR 6.29.2).

3520.55

-

-

... More
Columns, piers, abutments, pillars, posts and struts. (HSR 6.29.3).

4839.57

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for:- (HSR 6.30). Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. (HSR 6.30.2).

12281.35

-

-

... More
Suspended floors, roofs, landings, balconies and access platform. (HSR 6.30.3).

73740.15

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers. (HSR 6.30.5).

63828.64

-

-

... More
Columns, Pillars, Piers, Abutments, Posts and Struts. (HSR 6.30.6)

32745.93

-

-

... More
Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards. (HSR 6.30.13)

5687.8

-

-

... More
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (6) Thermo-Mechanically Treated bars of grade Fe-500D or more. (HSR 6.33.6)

1827792.58

-

-

... More
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (6) Thermo-Mechanically Treated bars of grade Fe-500D or more. (HSR 6.34.6)

3437609.67

-

-

... More
Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. (1) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.39.1).

319.59

-

-

... More
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminium base members, self aligning/self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical location in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminium base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall confirm to ASTM 6063). (1) Floor Joint of 100 mm gap. (HSR 6.61.1).

1941.15

-

-

... More
Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminium base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminium profiles exhibiting minimal exposed aluminium surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). (1) Wall Joint of 100 mm gap. (HSR 6.62.1).

1941.15

-

-

... More
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminium base members with, self aligning and self centering arrangement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminium base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063). (1) Roof Joint of 100 mm gap. (HSR 6.63.1).

1941.15

-

-

... More
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: (HSR 7.20). (1) Cement Mortar 1:4 (1 cement : 4 coarse sand).

518.01

-

-

... More
(2) Cement Mortar 1:6 (1 cement : 6 coarse sand).

1157.44

-

-

... More
Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor four level in cement mortar: (2) With Modular bricks. (HSR 7.23.2). (1) Cement Mortar 1:4 (1 cement : 4 coarse sand).

460.71

-

-

... More
(2) Cement Mortar 1:6 (1 cement : 6 coarse sand).

5574.2

-

-

... More
Half brick masonry with common burnt clay non-modular bricks of class designation 7.5 in superstructure above plinth level up to floor IV level. (2) Cement mortar 1:4 (1 cement :4 coarse sand). (HSR 7.28.2).

27430.48

-

-

... More
Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor IV level in : (2) Cement mortar 1:6 (1 cement : 6 Coarse sand). (HSR 7.47.2)

5574.2

-

-

... More
Dressed or moulded three brick cornice laid in cement sand mortar 1:4 including 12 mm thick cement plaster 1:4 or pointing, as required. (HSR 7.56).

76.98

-

-

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (2) Granite Work. (HSR 8.27.2).

5647.71

-

-

... More
Providing and fixing facing extruded clay Tile (Glass Reinforced Clay Tiles (GRC) any size any shade & design on wall with under layer of 12 mm thick cement plaster 1:3 and jointed with neat cement matched with pigment complete as per drawings,specifications and to the entire satisfaction of engineer- in- charge. (HSR 8.31).

7819.68

-

-

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : (1) In 75x75 mm deep chase. (HSR 9.17.1).

3655.34

-

-

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (HSR 9.18).

342

-

-

... More
Providing & fixing UV stabilised fibreglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. (1) 2 mm thick corrugated (2.5" or 4.2" or 6") or step-down (2" or 3" or 6" ) as specified. (HSR 9.32.1).

2884.7

-

-

... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (1) GI Metal Ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. (HSR 9.47.1).

9001.46

-

-

... More
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size (24x24X3000) mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. (HSR 9.48)

18002.9

-

-

... More
Supplying and fixing in position 60 cm long G.I. pipe class ‘B’ spouts in chajjas and cantilevers. (5) 50 mm internal dia. (HSR 9.55.5).

429.9

-

-

... More
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (9.57) (2) 110 mm diameter. (HSR 9.57.2)

315.3

-

-

... More
(3) 150 mm diameter. (HSR 9.57.3)

3574.41

-

-

... More
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (5) Bend 87.5°. (HSR 9.58.5). (2) 110 mm diameter. (HSR 9.58.5.2).

138

-

-

... More
(3) 150 mm diameter. (HSR 9.58.5.3).

338

-

-

... More
Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. (HSR 10.1).

13548.45

-

-

... More
Providing and laying of screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping. (HSR 10.4).

55350.51

-

-

... More
Providing and laying of conglomerate floor 50mm thick cement concrete topping 1:2:4. (HSR 10.7).

455

-

-

... More
Providing and fixing glass strips in joints of terrazzo/ cement concrete floors. (1) 40 mm wide and 4 mm thick. (HSR 10.22.1).

1935.38

-

-

... More
Providing and laying of precast terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 12 mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement:4 coarse sand) : (2) Medium shade pigment using 50% white cement and 50% ordinary cement. (HSR 10.26.2)

1228.99

-

-

... More
Providing and laying of precast terrazzo tiles 20 to 22 mm thick with graded marble chips of sizes up to 12 mm, in skirting and risers of steps not exceeding 30 cm in height, on 12 mm thick cement plaster 1:3 (1 cement : 3 coarse sand), jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of : (2) Medium shades pigment using 50% white cement and 50% ordinary cement. (HSR 10.28.2)

133.07

-

-

... More
Providing and laying of chequered terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : (1) Light shade pigment using white cement. (HSR 10.29.1).

3724.44

-

-

... More
Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : (1) 25 mm thick. (HSR 10.37.1).

28121.52

-

-

... More
Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (HSR 10.38).

1914.73

-

-

... More
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. (HSR 10.42)

2194.23

-

-

... More
Laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (1) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (HSR 10.50.1). (LABOUR RATE ONLY)

19717.28

-

-

... More
Fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. (HSR 10.51). (LABOUR RATE ONLY).

2703.62

-

-

... More
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (HSR 10.58).

20346.86

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. (HSR 10.59).

2801.43

-

-

... More
Laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (3) Size of Tile 800x800 mm. (HSR 10.63.3). (LABOUR RATE ONLY).

12320.44

-

-

... More
Laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. (3) Size of Tile 800x800 mm. (HSR 10.67.3). (LABOUR RATE ONLY).

1504.03

-

-

... More
Providing and laying 80mm thick factory made cement concrete interlocking paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over (BIS 15658:2006) and including 60mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. (HSR 10.77).

32082.34

-

-

... More
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. (HSR 10.107).

1853.36

-

-

... More
10 mm thick cement plaster. (2) 1:3 (1 cement: 3 fine sand). (HSR 11.4.2).

68852.68

-

-

... More
12 mm cement plaster of mix: (HSR 11.5). (3) 1:4 (1 cement: 4 fine sand). (HSR 11.5.3).

2435.77

-

-

... More
(4) 1:6 (1 cement: 6 fine sand). (HSR 11.5.4).

78480.22

-

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix: (HSR 11.6). (1) 1:4 (1 cement: 6 fine sand). (HSR 11.6.1)

2267.77

-

-

... More
(2) 1:6 (1 cement: 6 fine sand). (HSR 11.6.2)

87950.44

-

-

... More
Cement rendering on plaster 1 mm thick. (HSR 11.52).

168

-

-

... More
Applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (HSR 11.60). (LABOUR RATE ONLY)

227558.63

-

-

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : (1) New work (two or more coats) over and including water thinnable priming coat with cement primer. (HSR 11.64.1). (LABOUR RATE ONLY)

184547.02

-

-

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : (1) Water thinnable cement primer. (HSR 11.67.1). (LABOUR RATE ONLY)

2097.56

-

-

... More
Applying priming coat:- With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works. (HSR 11.68.3). (LABOUR RATE ONLY)

6484.06

-

-

... More
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. (HSR 11.76). (LABOUR RATE ONLY)

3153.77

-

-

... More
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 11.77). (LABOUR RATE ONLY)

3153.77

-

-

... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78). (LABOUR RATE ONLY)

3153.77

-

-

... More
Painting the wooden/metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade: (1) Two or more coats on new work. (HSR 11.82.1). (LABOUR RATE ONLY)

4315.77

-

-

... More
Finishing walls with textured exterior paint of required shade : (1) New work (Two or more coats applied @ 3.28 litre/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. (HSR 11.94.1). (LABOUR RATE ONLY)

7819.68

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade : (1) New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). (HSR 11.95.1). (LABOUR RATE ONLY)

48109.92

-

-

... More
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (2) Kiln seasoned and chemically treated Hollock wood. (2) 30 mm thick. (HSR 12.10.2.2)

69.23

-

-

... More
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws: (2) 30 mm thick shutters. (1) with ISI marked M.S. pressed butt hinges bright finished of required size. (2) 30 mm thick. (HSR 12.19.2.1.2).

81.46

-

-

... More
Planking of commercial hard wood, such as Hollock, champ, chikrassy and chaplash etc., (Non-coniferous timber other than teak conforming to I.S. specification no.1003 kiln-seasoned) planed on both sides, rebated and fixed in position, including nails and screws, etc:- (6) 20 mm thick. (HSR 12.24.6).

635.86

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (HSR 12.36). 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. (HSR 12.36.1)

297.49

-

-

... More
25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws. (HSR 12.36.3).

77.08

-

-

... More
Fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : (1) 150 mm. (HSR 12.60.1). (LABOUR RATE ONLY)

504

-

-

... More
Fixing oxidised M.S. double acting spring hinges with necessary screws etc. complete. (1) 150 mm. (HSR 12.64.1). (LABOUR RATE ONLY)

392

-

-

... More
Fixing 50 mm bright finished brass cup board or wardrobe knob of approved quality with necessary screws. (HSR 12.84). (LABOUR RATE ONLY).

946

-

-

... More
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 35 kg and door width up to 700 mm), with necessary accessories and screws etc. complete. (HSR 12.88).

2591

-

-

... More
Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. (HSR 12.97). 125x75x4 mm. (HSR 12.97.1)

8368

-

-

... More
100x75x4 mm. (HSR 12.97.3)

7792

-

-

... More
Fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete. (HSR 12.98). (LABOUR RATE ONLY) Size 300 mm x 16 mm. (HSR 12.98.1)

1558

-

-

... More
Size 250 mm x 16 mm. (HSR 12.98.2)

1006

-

-

... More
Fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete. (HSR 12.99). (LABOUR RATE ONLY) Size 200 mm x 10 mm. (HSR 12.99.3)

5376

-

-

... More
Size 150 mm x 10 mm. (HSR 12.99.4)

8746

-

-

... More
Size 100 mm x 10 mm. (HSR 12.99.5)

5712

-

-

... More
Fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. (HSR 12.102). (LABOUR RATE ONLY). 125 mm (HSR 12.102.1)

4278

-

-

... More
100 mm (HSR 12.102.2)

3178

-

-

... More
75 mm (HSR 12.102.3)

4798

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : (1) Fixed Portion. (1) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). (HSR 12.157.1.1).

79581.1

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : (2) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). (1) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade AC 15). (HSR 12.157.2.1).

45214.07

-

-

... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. (2) Pre-laminated particle board with decorative lamination on both sides. (HSR 12.158.2).

11133.24

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): (2) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm). (HSR 12.159.2).

4935.55

-

-

... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body/plate with double spring mechanism and door weight up to 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (1) With stainless steel cover plate minimum 1.25 mm thickness. (HSR 12.160.1).

207

-

-

... More
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge. (1) Anodized (AC 15) aluminium. (HSR 12.167.1).

404

-

-

... More
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). (HSR 12.170).

113260.68

-

-

... More
Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). (1) Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)(HSR 12.176.1).

742.62

-

-

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: (HSR 13.3). Profile B Fixing with adjustable lugs with split end tail to each jamb. (HSR 13.3.1.1).

1437.86

-

-

... More
Profile E Fixing with adjustable lugs with split end tail to each jamb. (HSR 13.3.3.1).

1280.81

-

-

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (2) 5.5 mm thick glass panes. (HSR 13.10.2).

2132.63

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (HSR 13.28).

125643.59

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (2) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (HSR 13.29.2)

59628.1

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. (1) 80x1.25 mm M.S. laths with 1.25 mm thick top cover. (13.37.1)

42.35

-

-

... More
Extra for providing mechanical device chain and crank operation for operating rolling shutters. (1) Exceeding 10.00 sqm and up to 16.80 sqm in the area. (HSR 13.39.1).

42.35

-

-

... More
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (HSR 13.41).

39964.63

-

-

... More
Compaction of Earthwork. (3) Compaction of & preparation of sub grade including loosening, levelling of earth 225 mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 3000-2 as per technical clause 305 of MORT&H specifications (in case of link roads earthwork to be done by villagers). (HSR 17.5.3).

32082.34

-

-

... More
Excavation for Roadway in Soil by Mechanical means and Tippers with Disposal up to 1000 metres. (1) Excavation for roadwork in soil by mechanical means including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead up to 1000m as per technical clause 301 of MORT&H specifications. (HSR 17.10.1)

174502.34

-

-

... More
Granular Sub-Base with Close Graded Material - (Table:- 400-1) Plant mix method. Construction of granular sub-base by providing Material as per Grading III (Table 400-I of MORT&H 5th revision) mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORT&H specifications. (3) Grading III material. (HSR 17.14.3).

6550.21

-

-

... More
Water Bound Macadam - II with crushable screenings. Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications. (HSR 17.23.3).

2444.11

-

-

... More
Dry Lean Cement Concrete Sub- base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing, as per clause 601 of MORT&H specifications. (HSR 17.44).

3255.55

-

-

... More
Cutting holes upto 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including, repointing, replastering, replacing bitumen and colour or white washing where required. (HSR 20.28). 115 mm thickness of roof or floor. (HSR 20.28.2)

537

-

-

... More
150 mm thickness of roof or floor. (HSR 20.28.3)

687

-

-

... More
Supplying and applying waterproofing treatment for 'Raft Slab' by using 1.2 mm thick fully bonded HDPE sheet membrane complying to BS8102:2009/ IS 16471-2017. The HDPE shall be virgin HDPE & not recycled, thickness of bare HDPE shall not be less than 0.8 mm coated with pressure sensitive adhesive layer and a trafficable granular top layer. The HDPE membrane shall have the following typical properties: 1. Tensile Strength : 27 Mpa ( as per ASTM D412) 2. Puncture Resistance: 1000N±5% (as per ASTM E154) 3. Elongation: 500% 4. Peel adhesion to concrete: 1500N/m (as per ASTM D903 Modified) 5. Resistance to Hydrostatic Head: 70 metre (as per ASTM D751-06(2011) 6. UV exposure test (60 days): No change 7. Lap Joint Strength : 1500N/m (as per ASTM D1876) HDPE Membrane shall be installed over the entire PCC area with standard 75 mm selvedge laps and end laps overlaid with HDPE Sealed Tape as per manufacturer's instructions. The rates are inclusive of supply and installation of membrane as per manufacturer methodology. The rates are inclusive of surface preparation, injection grouting at honeycombed areas all complete as per manufacturer methodology. (HSR 28.8).

11212.03

-

-

... More
Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer's specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. (HSR 28.18).

29659.2

-

-

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. (HSR 28.20).

6564.96

-

-

... More
Providing fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 50mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building. (HSR 28.40).

11170.15

-

-

... More
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) 78, solar reflection 0.70 and initial emittance 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner. (HSR 28.43).

11170.15

-

-

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (HSR 29.6). (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminium sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimensional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon separator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Notes for Item 29.6: 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm up to two decimal places. 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 sqm from the certified laboratories accreditated by NABL (National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. 3. Competent authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 3.1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 3.2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3.3 Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range up to 2000 ml 3.4 Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range up to 50 mm 3.5 Seismic Movement Test (up to 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 3.6 Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) up to 2000 ml

156.79

-

-

... More
Providing & Fixing in place metallic all Plain Wood finish Non Fire doors finished with wooden shades as desired by EngineerIn-Charge. Over all of thickness of the shutter to be 46mm thick manufactured from 0.8mm GPSP Galvanised Steel Sheet confirming to (IS277) With provision of Reinforcement Pad and necressary provision for the recieving appropriate hardwares. The Shutter shall be filled with Paper Honeycomb core in fill. Doors to be Coated with pure polyster/Epoxy Polyster powder having coating thickness of 60-80 micron. (HSR 32.50).

3306.04

-

-

... More
Providing & Fixing in place door frame of Section 170x58mm made of GPSP Sheet ( IS277) constructed from sheet thickness 1.2mm with a single rebate of 58mm duly filled with Puf and finished with Powder Coating In Reqular RAL shades as desired by Engineer- In-Charge . Frame should be Coated with pure polyster/Epoxy Polyster powder coating having thickness of 60-80 micron and provided with 3mm thick hinge reforcement plates. (HSR 32.57).

11002.6

-

-

... More
PUBLIC HEALTH WORK Drilling and tapping cast iron pipe lines of all diameters and screwing in ferrule and connections - (6) Ferrule size 40 mm. (HSR 20.24.6).

10

-

-

... More
Cutting holes up to 23 cm square through brick work in mud walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. (HSR 20.25) 11.43 cm thickness of walls. (HSR 20.25.1).

1768

-

-

... More
22.86 cm thickness of walls. (HSR 20.25.2).

2356

-

-

... More
Labour our fixing G.I. or W.I. pipe sleeve pieces in holes in walls, floors, and roofs rounds pipes including all cutting and wastage. (HSR 20.29). 15 mm internal diameter of sleeve pipe. (HSR 20.29.1).

13

-

-

... More
20 mm internal diameter of sleeve pipe. (HSR 20.29.2).

13

-

-

... More
25 mm internal diameter of sleeve pipe. (HSR 20.29.3).

13

-

-

... More
32 mm internal diameter of sleeve pipe. (HSR 20.29.4).

10

-

-

... More
40 mm internal diameter of sleeve pipe. (HSR 20.29.5).

10

-

-

... More
Bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge. Size of the main with which connection is to be made. (1) Up to 200 mm internal diametre. (HSR 20.49.1).

10

-

-

... More
Providing & fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge. (HSR 21.28).

210

-

-

... More
Extra for every 0.30 metre depth of Inspection chamber. (3) 600 mm x 900 mm inside. (HSR 21.85.3).

3

-

-

... More
Providing salt glazed stone ware pipes grade ‘A’ in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described in item No. 21.38, 21.39, item 21.40 including the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in-charge. (HSR 21.94). 200 mm Internal diameter. (HSR 21.94.3)

1375

-

-

... More
250 mm Internal diameter. (HSR 21.94.4)

530.51

-

-

... More
Providing lowering cutting jointing and testing RCC pipe class NP3 as per IS-458-2003 with spigot & socketed joints manufactured with ISI marked sulphate resistance cement as per ISI 12330 with rubber rings ISI marked antiternmite as required at site in to trenches for all depths and laying out the same to correct alignment gradients and levels including dressing and trimming and cutting of concrete beds and side of trenches, if required jointing with rubber rings in trenches and jointing with 1:3/2 cement sand mortar and with end dowels filled with 1:3/2 cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints cutting and finishing the cut surface to a uniform finish etc. as fully described in item No. 21.38, item 21.44, item 21.45, & item 21.46 including cartage loading and unloading complete in all respects. the internal diametric of the sewer being: (HSR 21.95) 350 mm dia. (HSR 21.95.1).

1900

-

-

... More
400 mm dia. (HSR 21.95.2).

5332.47

-

-

... More
Supplying, erection, testing and commissioning of Submersible motor pumping set non clog for sewerage having head 10.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP Make: KSB, CRI, Kirlosker, Crompton Greeve, Lubi). (HSR 21.104.23). 1400 LPM 5HP.

2

-

-

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (2) Kitchen sink without drain board. (2) 610x460 mm bowl depth 200 mm. (HSR 22.10.2.2).

326

-

-

... More
Fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (1) 15 mm nominal dia. (HSR 22.12.1). (LABOUR RATE ONLY).

222

-

-

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (2) Flexible pipe. (1) 32 mm dia. (HSR 22.14.2.1).

627

-

-

... More
Fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (HSR 22.15). (LABOUR RATE ONLY)

627

-

-

... More
Providing and fixing 40mm i/d G.I. waste pipe embedded in walls up to floor level including cost of union and plumber joint. (HSR 22.16).

326

-

-

... More
Providing and fixing 40mm i/d chromium plated trap with chromium plated pipe to wall with walflange completed for use with sinks. (1) With Bottle Trap (Indian make). (HSR 22.17.1).

326

-

-

... More
Fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (1) White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. (HSR 22.22.1). (LABOUR RATE ONLY)

80

-

-

... More
Fixing white vitreous chinaware flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (1) One urinal basin with 5 litre white P.V.C. automatic flushing cistern. (HSR 22.25.1). (LABOUR RATE ONLY).

230

-

-

... More
Fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. (HSR 22.33). (LABOUR RATE ONLY)

570

-

-

... More
Fixing toilet paper holder : (1) C.P. brass. (HSR 22.42.1). (LABOUR RATE ONLY)

570

-

-

... More
Fixing partitions for different type of urinals. (1) Vitreous Chinaware Partition plate. (2) Large size 835mm x 355 mm. (1) White. (HSR 22.50.1.2.1). (LABOUR RATE ONLY)

230

-

-

... More
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. (HSR 22.53). 100 mm dia pipe. (HSR 22.53.1)

2587

-

-

... More
75 mm dia pipe. (HSR 22.53.2)

3557

-

-

... More
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: (2) 100 mm inlet and 75 mm outlet. (1) Sand cast iron S&S as per IS - 3989. (HSR 22.80.2.1).

2761

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (HSR 22.85). 32 mm nominal outer dia Pipes. (HSR 22.85.4)

2536.88

-

-

... More
40 mm nominal outer dia Pipes. (HSR 22.85.5).

1426.84

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (HSR 22.86). 15 mm nominal outer dia Pipes. (HSR 22.86.1).

8454.58

-

-

... More
20 mm nominal outer dia Pipes. (HSR 22.86.2)

8820.97

-

-

... More
25 mm nominal outer dia Pipes. (HSR 22.86.3).

3957.91

-

-

... More
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work). (HSR 22.94). 15 mm nominal bore. (HSR 22.94.1)

810

-

-

... More
20 mm nominal bore. (HSR 22.94.2)

1060

-

-

... More
25 mm nominal bore. (HSR 22.94.3)

576

-

-

... More
32 mm nominal bore. (HSR 22.94.4)

480

-

-

... More
40 mm nominal bore. (HSR 22.94.5)

245

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (HSR 22.98). 25 mm nominal bore. (HSR 22.98.1)

389

-

-

... More
20 mm nominal bore. (HSR 22.98.2)

1544

-

-

... More
32 mm nominal bore. (HSR 22.98.3)

352

-

-

... More
40 mm nominal bore. (HSR 22.98.4)

193

-

-

... More
Providing and fixing Unplasticised PVC connection pipe with brass unions: (2) 45 cm length. (1) 15 mm nominal bore. (HSR 22.101.2.1).

3435

-

-

... More
Fixing C.P. brass shower rose with 15 or 20 mm inlet : (2) 150 mm diameter. (HSR 22.102.2). (LABOUR RATE ONLY)

199

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. (2) 20 mm nominal bore. (HSR 22.103.2).

260

-

-

... More
Fixing C.P. brass bib cock of approved quality conforming to IS:8931 : (1) 15 mm nominal bore. (HSR 22.104.1). (LABOUR RATE ONLY)

173

-

-

... More
Fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. (1) 15 mm nominal bore. (HSR 22.106.1). (LABOUR RATE ONLY)

2571

-

-

... More
Fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. (1) 15 mm nominal bore. (HSR 22.107.1). (LABOUR RATE ONLY)

3447

-

-

... More
Fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. (HSR 22.117). (LABOUR RATE ONLY).

953

-

-

... More
Fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (2) 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. (HSR 22.119.2). (LABOUR RATE ONLY)

953

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : (1) 100 mm diameter S.W. pipe. (HSR 22.164.1).

9134.61

-

-

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: (1) 100x100 mm size P type. (1) With common burnt clay non-modular bricks of class designation 7.5. (HSR 22.166.1.1).

256

-

-

... More
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: With common burnt clay non-modular bricks of class designation 7.5. (HSR 22.179). Inside dimensions 455x610 mm and 45 cm deep for single pipe line : (HSR 22.179.1)

119

-

-

... More
Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets: (HSR 22.179.2)

119

-

-

... More
Inside dimensions 600x850 mm and 45 cm deep for pipe line with three or more inlets: (HSR 22.179.3)

129

-

-

... More
Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. (HSR 22.182).

306000

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : (HSR 22.190) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay non-modular bricks of class designation 7.5. (HSR 22.190.1.1).

72

-

-

... More
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay non-modular bricks of class designation 7.5. (HSR 22.190.2.1).

72

-

-

... More
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With common burnt clay non-modular bricks of class designation 7.5. (HSR 22.190.3.1).

72

-

-

... More
Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg. (HSR 22.202).

232

-

-

... More
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : (1) With common burnt clay non-modular bricks of class designation 7.5. (HSR 22.205.1).

176

-

-

... More
Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (HSR 22.209).

1065

-

-

... More
Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. (HSR 22.211).

953

-

-

... More
Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc. (1) C.P Brass. (2) Two Way. (HSR 22.212.1.2).

1472

-

-

... More
Providing and fixing PTMT pillar cock of approved quality and colour. (1) 15 mm nominal bore, 107 mm long, weighing not less than 110 gms. (HSR 22.213.1).

953

-

-

... More
Fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. (2) Size 550 mm x 400 mm x 815 mm. (HSR 22.221.2). (LABOUR RATE ONLY)

627

-

-

... More
Providing and fixing in position single socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. (2) Single Socket Type B. (2) 110mm o/d SWR UPVC pipe lines laid complete. (HSR 22.222). 110mm o/d SWR UPVC pipe lines laid complete. (HSR 22.222.2.2).

6750.78

-

-

... More
75mm o/d SWR UPVC pipe lines laid complete. (HSR 22.222.2.4).

12767.22

-

-

... More
Supply and erection of Three Phase weather proof M.S. box of size 30 cm x 20 cm x 15 cm with hinged cover made of 2 mm thick MS sheet, locking arrangements, housed in wall/fixed on pole , including the cost of 1 no 4 way 16 A Bakelite connector, 1 no. 16 amp TP MCB and 4 Nos. 16 amp. neutral links fixed on Bakelite sheet in the M.S. box and necessary connections. (HSR 24.4.6).

2

-

-

... More
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. (1) 32 mm dia. (HSR 24.4.7.1).

100

-

-

... More
Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge. (2) Submersible Copper Cable 3 Core 2.5 sqmm. (HSR 24.5.1.2).

280

-

-

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, up to 90 metre depth below ground level. (i) All type of Soil. (i) 300 mm dia. (HSR 33.6.1.1)

630

-

-

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & up to 150 metre depth below ground level. (i) All type of Soil. (i) 300 mm dia. (HSR 33.7.1.1)

110

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, Unplasticised PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (3) 200 mm nominal size dia. (HSR 33.8.3).

1130

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well Unplasticised PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (3) 200 mm nominal size dia. (HSR 33.9.3).

78.75

-

-

... More
Supplying, filling, spreading & levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (HSR 33.12).

71.3

-

-

... More
Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (HSR 33.13).

53.5

-

-

... More
Supplying, filling, spreading & levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. (HSR 33.14).

35.65

-

-

... More
Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. (HSR 33.15).

59.35

-

-

... More
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). (2) 150 mm dia. (HSR 33.18.2).

5

-

-

... More
Fire Fighting System Providing laying ,testing & commissioning of ( C ) class heavy duty MS pipe conforming to IS 3589/ IS 1239 including Welding ,fittings like elbows ,tees ,flanges,tapers ,nuts bolt ,gaskets etc . And fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complite as required . MAKE HISAR JINDEL, TATA, PARKSH SURYA . 250 mm dia ( MINIMUM 6.3 MM THIKNESS ) (DSR code No. 7.10)

36

-

-

... More
200 mm dia ( MINIMUM 6.3 MM THIKNESS ) (DSR code No. 7.9)

24

-

-

... More
150 mm dia. (DSR code No. 7.8)

400

-

-

... More
100 mm dia. (DSR code No. 7.7)

1600

-

-

... More
80 mm dia. (DSR code No. 7.6)

1450

-

-

... More
65 mm dia. (DSR code No. 7.5)

1600

-

-

... More
50 mm dia FOR DRAIN. (DSR code No. 7.4)

1200

-

-

... More
40 mm dia. (DSR code No. 7.3)

550

-

-

... More
32 mm dia. (DSR code No. 7.2)

3000

-

-

... More
25 mm dia. (DSR code No. 7.1)

14000

-

-

... More
Providing laying ,testing & commissioning of ( C ) class heavy duty MS pipe conforming to IS IS 1239 /3589 i/c fitting like elbows ,tees ,flanges ,tapers ,nuts bolt , gaskets etc .in ground including welding ,excavation & providing cement concrete blocks as supports , anticorrosive treatment with coaltar /asphalt tape as per IS 10221 reffilling the trench etc .of following sizes complete as required make PYPECOAT/COALTEK 150 mm dia (MINIMUM 6.3 MM THIKNESS) (DSR code No. 6.2)

2250

-

-

... More
Providing, fixing, testing & commissioning of 15 mm dia quartzoid bulb type brass sprinklers of rating 68 degree centigrade with required accessories Pendent type. ( DSR- 21.1 )

4000

-

-

... More
Providing ,fixing ,testing & commissioning of 15 mm dia quartzoid bulb type brass sprinklers of rating 68 degree centigrade with required accessories SIDEWALL ( DSR- 21.3 )

1000

-

-

... More
Providing ,fixing ,testing & commissioning of 15 mm dia quartzoid bulb type brass sprinklers of rating 79 degree centigrade with required accessories Pendent type ( MAKE: TYCO /SAFEX/ HD/ ,FIRE CUT, NEW AGE ) (NS)

35

-

-

... More
Providing ,fixing ,testing & commissioning of 15 mm dia quartzoid bulb type brass sprinklers of rating 68 degree centigrade with required accessories UPRIGHTsprinkler type ( DSR- 21.2 )

1500

-

-

... More
Providing ,fixing ,testing & commissioning of water curtain nozzle 15 mm dia nickel chrome plated brass , BSPT , K-factor as per design consideration complete as required . ( MAKE: TYCO /SAFEX/ HD/ KARTAR ,FIRE CUT, NEW AGE) (DSR- 27 )

850

-

-

... More
Supply , installation ,testing & commissioning of sprinkler flexible pipe 1500 mm ( UL listed ) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (BURST ) with branch line ( inlet ) 25 mm NPT male thread to sprinkler head (outlet ) 15 mm NPTfemale thread with reducer ,nipple ,2 side brackets , center bracket , stockbar of following sizes complite as required (DSR code No. 25.4)

3000

-

-

... More
Supplying and fixing single headed internal and external yard hydrent valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 ( TYPE -A ) with blank stainless steel cap and chain as required (DSR code No. 9.2)

130

-

-

... More
SITC of INTERNAL OR EXTERNAL weather proof standard fire hose cabinet (750 mm x 600 mm x 250 mm deep) for yard hydrants made of 16 SWG powder coated M.S. sheet having single or double opening glazed (4.0 mm thick glass) shutter including necessary locking arrangement by allan key, stove enamelled Fire red finish with " Fire Hose" marked on front, suitable for housing 2 nos. Hose pipe, 1 No. branch pipe & nozzle spanner. (For external hydrant system) (MAKE: / FIRE CUT / MINIMAX / NEW AGE/ SUPEREX / KARTAR). (NS).

130

-

-

... More
Supplying and fixing 63 mm dia ,15 m long RRL hose pipe with 63 mm dia male and femaile coupling duly bond with GI WIRE , RIVETS ETC . CONFORMING TO IS 636 (Type -A ) as required . (MAKE: / FIRE CUT /NEWAGE/ / MINIMAX/,KARTAR/ SAFEX (DSR code No. 16.2)

260

-

-

... More
Supplying & fixing 63 mm dia Stainless Steel (grade 304 ) short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 sutitable for instantaneous connection to iIS 903 sutitable for instantaneous connection to interconnect hose pipe coupling as required. (DSR code No. 18.2)

130

-

-

... More
Supplying and fixing firsr-aid Hose Reel with MS construction spray painted in post office red , conforming to IS 884 complite with the follwing as required . 20 mm nominal internal dia water hose thermoplastic (Textile reinforced ) type-2 as per IS 12585. 20 mm normal internal dia gun metal globe & nozzle. Drum and brackets for fixing the equipmets on wall.connections from riser with 25 mm dia stop gunmetal valve & MSpipe and socket (DSR Code No.17.1)

130

-

-

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd , for sutitable dia MS pipe connection conforming to IS 904 AS REQUIRED .4 WAY -150 mm dia MS pipe. (DSR code No. 19.2)

12

-

-

... More
Providing , installation , testing and commissioning of stainless steel Y- strainer fabricated out of 1.6 mm thick stainless steel, grade 304 , sheet with 3 mm dia hole with stainless steel flange . 250 mm dia . (DSR code No. 15.5)

6

-

-

... More
Supplying and fixing air vessel made of 250 mm dia ,8 mm thick MS sheet , 1200 mm in height with air release valve on top and flanged connection to riser , drain arrangement with 25 mm dia gun metal wheel valve with required accessories , pressure gauge and paintingwith synthetic enamel paint of approved shade as required . (DSR code No. 20)

4

-

-

... More
SITC OF Providing & Fixing of air vessel 450/1600 0mm dia,height with dish top made in 6mm thick ms pipe complete with 20 mm dia brass air valve , 200mm dia stop valve , pressure gauge ,stop cock, nipple for fire control room ( NS )

4

-

-

... More
Supplying and fixing orifice plate made out of 6mm thick stainless steel ( Grade 304 ) with orrice of required size to be fitted between flange & landing valve of external and internal hydrent to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required .MAKE-SANT,LEADER,KARTAR / SAFEX OR EQULENT (DSR code No. 13)

40

-

-

... More
Supplying , fixing , testing and commissioning of butterfly vave of PN 1.6 rating with bronze /gunmetal seat duly ISI markedcomplete with nuts , bolt , washers ,gaskets conforming to IS 13095 OF FLOWING SIZES AS REQUIRED 250 mm dia. (DSR code No. 11.8)

8

-

-

... More
150 mm dia. (DSR code No. 11.6)

40

-

-

... More
100 mm dia. DSR code No. 11.5)

60

-

-

... More
80 mm dia. (DSR code No. 11.4 )

150

-

-

... More
50 mm dia. (DSR code No. 11.2)

30

-

-

... More
Providing , installation , testing and commissioning of non-return valve of following sizes confirming to IS 5312 complete with rubber gasket . GI bolt ,nuts , washers etc .as required 250 mm dia. (DSR code No. 14.9)

2

-

-

... More
150 mm dia. (DSR code No. 14.7)

15

-

-

... More
100 mm dia. (DSR code No. 14.5)

10

-

-

... More
providing & fixing of pressure switch in M.S pipe line including connection. (DSR code No. 22)

7

-

-

... More
SITC of fire brigade draw off connection confirming to IS : 4038-1986 with 150 mm Non return valve/ strainer incluiding necessary fittings the word FIRE BRIGADE DRAW OFF to be painted on the box complete all as specified and directed.( ( N.S )

30

-

-

... More
Providing, fixing, testing & commissioning of 100 mm dia Burden type, Stainless Steel dial type pressure gauge (in Pump Room) including brass isolation valve and pipe having caliberation of 0-15 Kg/cm2. MAKE H.GURU/FIEBIG (NS).

100

-

-

... More
Supplying , installation , testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following , complite in all respect , as required. ( Diesel Driven Pump ) horizontal type , multistage , centrifugal pump of cast of iron body and brinze impeller with stainless steel shaft , mechanical seal conforming to IS 1520 OF Suitable HP ,1500 RPM water cooled with radiator , diesel engine conforming to relevant IS standard complete with autostarting mechanism , 12 /24 volt electric starting equipment , disel tank , exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick almunium sheet cladding , residebtial silencer , instruments and protection as per standard specification ,stop solenoid for auto stop in the ecent of fault with audio indications , painted with post office red colour etc. as required. M.S fabricated ,common base plate coupling ,coupling guard , foundation bolt etc. as required. 2280 LPM at 88 Mtr Head, ( DSR- 2.4 )

2

-

-

... More
Supplying , installation , testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following , complite in all respect , as required. (Diesel Driven Pump ) horizontal type , multistage , centrifugal pump of cast of iron body and brinze impeller with stainless steel shaft , mechanical seal conforming to IS 1520 OF Suitable HP ,1500 RPM water cooled with radiator , diesel engine conforming to relevant IS standard complete with autostarting mechanism , 12 /24 volt electric starting equipment , disel tank , exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick almunium sheet cladding , residebtial silencer , instruments and protection as per standard specification ,stop solenoid for auto stop in the ecent of fault with audio indications , painted with post office red colour etc .as required . M.S fabricated ,common base plate coupling ,coupling guard , foundation bolt etc .as required . 2280 LPM 70 MTR HEAD (DSR 2.5)

1

-

-

... More
Supplying , installation , testing and commissioning of electric driven Main Fire Pump suitable for automatic operation and consisting of following , complete in all respects , as required . (a ) Horizontal type, multistage , centrifugal , split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) suitable HP squirrel cage induction motor ,TEFC , synchronous speed 1500 RPM ,suitable for operation on 415 volt , 3 phase 50 Hz ,ac supply with IP 55 protection for enclosure , horizontal foot mounted type with class ' F ' insulations , conforming IS -325 FOR HYDRENT SYSTEM ( DSR- 1.4 ) 2280 LPM suitable for 88Mtr Head ( DSR- 1.4 )

6

-

-

... More
Supplying , installation , testing and commissioning of electric driven Main Fire Pump suitable for automatic operation and consisting of following , complete in all respects , as required . (a) Horizontal type , multistage , centrifugal , split casing pump of cast iron body & bronze impeller with stainless steel shaft , mechanical seal conforming to IS 1520. (b) suitable HP squirrel cage induction motor ,TEFC , synchronous speed 1500 RPM ,suitable for operation on 415 volt , 3 phase 50 Hz ,ac supply with IP 55 protection for enclosure , horizontal foot mounted type with class ' F ' insulations , conforming IS -325 FOR HYDRENT SYSTEM ( DSR- 2280 lpm 70 mtr head1.5)

2

-

-

... More
Supplying , installation , testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following , complete in all respects , as required ; (Jockey Pump ) Horizontal type , multistage , centrifugal pump of cast iron body and bronze impeller with stainless steel shaft , mechanical seal conforming to IS; 1520 . Suitable HP squirell cage induction motor tefc type suitable for operation on 415 volt , 3 phase 50 HZ AC supply with IP 55 class of protection for enclosure , horzontal foot mounted type with class- ' F 'insulation,conforming to IS; 325 M .S fabricated common base plate , coupling ,coupling guard , foundation bolt etc as required . M.S fabricated bolt etc as required . Suitable cement concrete foundation duly plastered and with anti vibration pad. 180 LPM suitable for 88 Mtr ( DSR- 3.1 )

6

-

-

... More
Supplying , installation , testing and commissioning of electric driven Main Fire Pump suitable for automatic operation and consisting of following , complete in all respects , as required . (a ) Horizontal type , multistage , centrifugal , split casing pump of cast iron body & bronze impeller with stainless steel shaft , mechanical seal conforming to IS 1520 ( b ) suitable HP squirrel cage induction motor ,TEFC , synchronous speed 1500 RPM ,suitable for operation on 415 volt , 3 phase 50 Hz ,ac supply with IP 55 protection for enclosure , horizontal foot mounted type with class ' F ' insulations , conforming IS -325 FOR HYDRENT SYSTEM MAKE KILOSKER , LUBI MOTHER AND PLATT , ASHOK LEYLAND 2280 LPM suitable for 56 Mtr Head for water curtain in basement (DSR code No. 1.6 )

2

-

-

... More
Supplying , installation , testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following , complete in all respects , as required ; ( Terrace Pump ). (a) Horizontal type , multistage , centrifugal , split casing pump of cast iron body & bronze impeller with stainless steel shsft , mechanical confirming to IS; 1520. ( b ) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volt ,3 phase ,50 Hz , AC supply with IP55 class of protection for enclosure , horiziontal foot mounted type with class - 'F 'insulation , conforming to IS- 325 ( c ) M.S fabricated common base plate ,coupling ,coupling guard , foundation bolt etc as required . ( d ) Suitable cement concrete foundation duly plastered and with anti vibration pads . 450 LPM at 35 m head (DSR 4.2)

6

-

-

... More
SITC OF DOL type fire pump panel suitable for 900 lpm fire pump 415 V+/-6 volts,panel shall be free standing floor mounting sheet metal enclosed dust and verming proof.Panel shall be provided with heat shrinkable sleeves and shall be coloour coded. The panel shall be suitable for cable entry from top or bottem. The minimum fault rupturing for all incoming and outgoing switch/ breakers shall be 35 KA. The panel shall be fabricated.Auto mannual Starters with change over system. MAKE ( N.S )

3

-

-

... More
Supply, installation, testing and commissioning of Dewatering Submersible type, vertical resting pump for dewatering from Underground sumps/Pits suitable to deliver 120 LPM at 10M head (minimum HP=1 ). 415V, 50Hz, AC supply system, 2900 RPM, including providing required suspension or bracket supports, delivery connections, water proof windings, cable termination box etc suitable for under water application. The pumps shall have self level control including sensing probes or water/weather proof float switch for automatic controls complete KILOSKER ,LUBI ,CROMPTON ( N.S ) Note: Contractor to Guarantee the required discharge at required head from the pumps. The rating of motors to be property indicated for required head and discharge (selected for required duty points as per performance data of the pumps) The models to be got approved by the Architects before procurement. KW/HP/BHP of motors and engine shall finally be selected as per performance carve. Contractor to produce the required documents for such assessment at the time of purchase of pumps, motors and engines.

3

-

-

... More
Supplying and making end termination with brass compression gland and almminium lugs for following size of PVCand PVCsheathed /XLPE almuminium conductor cable of 1.1 KV grade as required (MAKE:RR/FINOLEX/polycab ) a) 3.CORE x 95 sq. mm (From Fire Fighting Control Panel to main fire AND SPRINKLAR pump) (DSR E & M code No. 9.1.13)

20

-

-

... More
b) 3 CORE x 35 sq. mm (From Fire Fighting panel to jockey pump) (DSR E & M code No. 9.1.10)

20

-

-

... More
c) 2 core x 1.5 sq .mm For pressure switch to fire panel and fire annuciator panel and flow switch ) supplying and drawing FRLS PVC insulated copper conductor cable (DSR E & M )code No. 1.17.2)

100

-

-

... More
d) 3.CORE x 10 sq. mm (From Fire Fighting Control Panel to main fire pump) (DSR E & M code No.9.1 .7

100

-

-

... More
Supply, installation, testing of 16 zone fire annuciatior indication panel location fire control room make fire cut /attack fire /hydrotec ( N.S )

3

-

-

... More
Providing & fixing flow switch in following sizes M.S pipe including connection etc as required .150 mm dia make system sensor / hd / new age . ( DSR - 23.2 )

16

-

-

... More
Providing & fixing of deluge valve ( to be used for water curtain ) UL listed with wet pilot basic trim assembly for DVA with test and alarm , drip and drain valve with water moter gong complete as required . 100 mm dia Make HD , SAFEX , MINIMAX ( DSR - 26.3 )

2

-

-

... More
Providig , installation , testing & commissioning of electric release trim assembly for deluge wall with two way solelnoid valve , weather proof operation on 24 volt DC supply complete as required . Make any standed ( DSR - 28 )

2

-

-

... More
Proviing , fixing , testing & commissioning of installation control valve of cast iron body , brass /bronze working parts comprising of water moter alarm , bronze seat clapper , clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser / sprinkler system activates , pressure switch, cock valve complete with drain valve and bypass , test control box , ball valves MS PIPE OF REQUIRED SIZE , FLANGES , ORIFICE PLATE , GASKET ETC OF FOLLWING SIZES AS REQUIRED 150 MM DIA (DSR code No. 24.3)

2

-

-

... More
Fabrication , supply, insallation testing & commissioning of electrical control panel of cubical construction , floor mounted type , fabricated out of 2mm thick Crca sheet , compartmentalised with hinged lockable door ,dust and vermin proof ,powder coated of approved shade after 7 tanktreatment process , cable alley ,interconnection with suitable size copper conducor cable /solid copper strip , having switchgears and accessories , numbering etc , completein all respect ,suitable for main fire pump , pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and outgoing , suitable for opreraton on 415v , 3 phase, 50 Hz Ac Supply with enclosure protection class IP 42 as required . INCOMING : 400 A , 50kA 4 pole MMCB ,lcs =100 %icu rating Digital Voltmeter 0-500 V with selector switch Ammeter (0-400 A ) with selector swtich & CTs etc . LED type RYB phase indicating lamps , ON , OFF , trip indicating lamps Set of copper bus baar 500a. Outgoings ( Note ;- ALL outgoing feeder for pumps should have digital Ammeter with selector switches , and LED type ON ,OFF ,trip indicating lamps ) MAIN FIRE PUMP 200 A , 50 kA TPN MCCB , ics =100% icu , with fully automatic star /delta starter sutable for 75 hp pump with overload protection , current sensingtype single phase preventor complete with all acceessories and internal wiring required for automatic operation , selector switch for locl /remote ,auto / manwel /off opreation . JOCKEY PUMP - 100 A ,50kA TPN MCCB ,ICS= 100 % 1CU with suitable HP fully automatic star/delta starter with overload protection ,current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation , selector switch for local / remote ,auto /manual /off operation . DIESEL ENGINE CONTROL- Control for diesel engine comprising - Automatic / Manual selctor switch & 3 attempt starting device , timers and relays as required , push buttons , start /stop in manual mode indication lamp for high /low lub ,oil pressure ,high water temp and engine on indication . Battery charger suitble for 12 V /24 V DC with boost and trickle selectorswitch , 0-30 V DC volt meter , and 0-20 A DC Ammeter , All standard relays and accessories for automatic opretion of diesel engine System controller Designing Supply installation , testing and commissioning of system controller to control operation of main electric fire pump ,disel pump ,pressurization pump in sequence as per specification consisting of relays ,timers sensors , annunciation window for fault indication ,complite as per specifications fire cut /attack fire /hydrotec ( DSR- 5.6 )

3

-

-

... More
AUTO GLOW EXIT SIGNS AND INDICATION SIGNS SIZE 12 "x 6", MAKE FIRE CUT AND ATTACK FIRE ,DP lndication every exit point,fire point,fire extinguisher. (NS).

800

-

-

... More
FIRE EXTINGUISHERS SUPPLY AND INSTALLATION of ISI marked (ISI MARK 15683) portable Co2 fire extinguisher of capacity 4.5 kg flat base including valve , dischargeone metar long hose of . meter complete in all respect with explosive certificate . ( N.S )

150

-

-

... More
SITC of ISI marked (IS: 15683) portable ABC multipurpose filled by 90% (MAP ) mono amonioum phosphate powder , nitrogen pressurised type fire extinguisher, Capacity 6 kg with 90% map complete in all resp. MAKE. (NS).

150

-

-

... More
SITC of Clean Agent type ISI mark IS code 15683 2006 Fire Extinguisher capacity: 2 kg location - o.t room ,nursing station, lab machinry room pantry kitchen ( N.S )

80

-

-

... More
SITC of 5 kg modular type self operated on 68o temperature Clean Agent type CE certified Fire Extinguisher filled with NAFPIV clean agent gas MAKE location electrical shaft ,electrical control room servar room other places where water or other camical are prohibited . ( N.S )

60

-

-

... More
SITC of 50 KG DCP (Dry Chemical Powder) Trolley type fire extinguisher as per IS 16018I jet length minimum 8 mtr minimum discharge time 40-50 sec,tested on 30 kgf/cm2 MAKE .location dg room , fire control room , ground floor of every block . (N.S )

20

-

-

... More
SITC of 50 KG Mechanical Foam AFFF Trolley type fire extinguisher as per IS 16018 jet length minimum 10 mtr minimum discharge time 60-180 sec,tested on 35 kgf/cm2 with 2 kg co2 external fire extinguisher MAKE location dg room , fire control room , ground floor of every block . ( N.S )

20

-

-

... More
SITC of 9 ltr capacity Fire Bucket made in 16 guage MS filled by 9 kg sand with MS angle stand having arrangement of hanging 6 buckets with shed. (NS).

26

-

-

... More
SITC OF 46 mm steel fire check door of 120 minut fire rating confirming to bs 476 part -22 and is 3614 part-11 fabricated with 2 no , 1mm thick galvnized steel sheet sandwiching with proprietary fire resistant insulation materials in between. The door frames are manufactured from 1.5mm thick galvanized steel sheet pressed from to double rebate profile of size 143mm x 57 mm . the door frame and door shutters to finish with powder coating SITC OF 2HR FIRE RATED METAL DOOR MAKE. location- basement stair case, electrical cantrol room and all floor stir case where there is no natural vantilation (NS) (Single Leaf 1200mm x 2100mm) Note: - 1. In case of any difference in the unit & nomenclature of any of the HSR/ DSR items of Civil, PH & EI work depicted in this DNIT and that given in HSR/ DSR, the unit and nomenclature given in HSR/ DSR shall be applicable. 2. The contractual agency will arrange approval of the fire scheme & fire NOC certificate from fire authority and for which 10% amount will be withheld till NOC is received.

40

-

-

... More
E.I portion COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS HSR 23.2 23.2.1 Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. 23.2.1.3 Group C 23.2.2 Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe.

9032

-

-

... More
23.2.2.3 Group C

207

-

-

... More
23.2.3 Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe, without separate control switch , Modular type Switch/sockets wiring 23.2.3.3 Group C

2050

-

-

... More
23.3.5 Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch required MS Box etc complete as required 23.3.5.3 Group C

2430

-

-

... More
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required..HSR 23.5.6 23.5.6.1) 1 run of Size 1.50 Sqmm(1/1.40mm)

15200

-

-

... More
23.5.6.2) 1 run of Size 2.50 Sqmm(1.1.80mm)

9820

-

-

... More
23.5.6.3) 1 run of Size 4 Sqmm(1/2.24mm)

8530

-

-

... More
23.5.6.5) 1 run of Size 10 Sqmm(1/3.50 mm)

2780

-

-

... More
23.5.6.6) 2 run of Size 1.50 Sqmm(1/1.40mm)

6450

-

-

... More
23.5.6.7) 2 run of Size 2.50 Sqmm(1.1.80mm)

2395

-

-

... More
23.5.6.8) 2 run of Size 4 Sqmm(1/2.24mm)

1755

-

-

... More
PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL HSR 23.7 23.7.6 Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. 23.7.6.1 PVC pipe of 20 mm dia.

6670

-

-

... More
23.7.6.2 PVC pipe of 25 mm dia.

6500

-

-

... More
23.7.6.3 PVC pipe of 32 mm dia.

1280

-

-

... More
FITTING AND ACCESSORIES HSR 23.8 23.8.1 Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. 23.8.1.6 Call bell 220/230 volts musical type

681

-

-

... More
23.8.1.12 Bakelite angle/straight button holder large size.

1033

-

-

... More
Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. HSR 23.8.4

3784

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. HSR 23.8.10 23.8.10.1)1 & 2 Modules including combined plate for Telephone and data

1276

-

-

... More
23.8.10.6)12 Modules

638

-

-

... More
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. HSR 23.8.11 23.8.11.1) 5 amp 1 way switch

1914

-

-

... More
23.8.11.3) 15 amp 1 way switch

638

-

-

... More
23.8.11.4) 5 amp Socket

1914

-

-

... More
23.8.11.5 ) 15 amp 6 pin Socket

638

-

-

... More
23.8.11.7) step type Fan Regulator 2 modules 300 watt

3784

-

-

... More
23.8.11.8) Telephone Socket outlet modular type

638

-

-

... More
23.8.11.9) TV Socket outlet modular type

50

-

-

... More
23.8.11.10) Blanking plate

1750

-

-

... More
23.8.11.11) RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type

638

-

-

... More
23.8.11.12) USB Charger, 1000mA, 5V, 1 Module ( For Non residential use only)

125

-

-

... More
Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work. HSR 23.9

639

-

-

... More
Erection of cabin fan complete with necessary earthling including carriage from PWD store to the site of work. HSR 23.10

50

-

-

... More
Supply, erection and fixing of 12 mm thick ply wood board having a circular /rectangular hole etc as required including the cost of making hole, nuts and bolts, painting and other petty material with all labour etc. complete in all respect up to the entire satisfaction of Engineer-in-charge of the work. HSR 23.13

2556

-

-

... More
Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required HSR 23.20

3007

-

-

... More
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. HSR 23.22 Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. HSR 23.22.1 23.22.1.3 TRIPLE POLE MCCB 16 to 100 Amp, 25 KA

20

-

-

... More
23.22.1.4 TRIPLE POLE MCCB 125 to 160 Amp, 25 KA

69

-

-

... More
23.22.1.5 TRIPLE POLE MCCB 200 to 250 Amp, 25 KA

29

-

-

... More
23.22.1.9) 4 pole MCCB 6 amp to 100 amp , 25 KA (For Rising Mains)

148

-

-

... More
23.22.1.10) 4 pole MCCB 125 to 160 amp, 25 KA (For Rising Mains)

19

-

-

... More
23.22.1.12) 4 pole MCCB 300 to 400 amp , 50 KA

2

-

-

... More
23.22.4 Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. 23.22.4.4) SPN DB Double Door 16 way ( 2 incoming and 14 outgoing)

28

-

-

... More
23.22.4.5) TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing)

88

-

-

... More
23.22.4.7 TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing)

62

-

-

... More
23.22.4.8 TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing)

14

-

-

... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- HSR 23.22.5 23.22.5.1) 6 amp. to 32 amp Single Pole

4250

-

-

... More
23.22.5.3) 6 amp. to 32 amp Double POLE

14

-

-

... More
23.22.5.4) 40 amp to 63 amp. Double pole

28

-

-

... More
23.22.5.6) 40 amp to 63 amp. MCB's TRIPLE POLE

20

-

-

... More
23.22.5.8) 40 amp to 63 amp. MCB's FOUR POLE

181

-

-

... More
Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. HSR 23.22.6 23.22.6.2 DP RCCB 30ma sensitivity , 40 A

14

-

-

... More
23.22.6.3 DP RCCB 30ma sensitivity , 63 A

14

-

-

... More
23.22.6.5 FP RCCB 30ma sensitivity, 40 A

10

-

-

... More
23.22.6.6 FP RCCB 30ma sensitivity, 63 A

95

-

-

... More
Supply and erection of blanking sheet in existing distribution board. HSR 23.22.7

235

-

-

... More
MISCELLANEOUS HSR 23.23 Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):-23.23.1 Size 25 mm dia

285

-

-

... More
MS STAND, BUS BAR CHAMBER AND PANELS HSR 23.24 23.24.1 Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide.

920

-

-

... More
Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. I volt meter with selector switch wiring (but EXLUDING COST of incoming and outgoing MCCB's ) etc.suitable for operation of 240/415 volts AC. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. HSR 23.24.4 23.24.4.1 Load Bank 4 way 250 amp.

2

-

-

... More
23.24.4.4 Load Bank 8 way 400 amp.

1

-

-

... More
SAFETY ITEMS HSR 23.26 23.26.1 Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages.

57

-

-

... More
23.26.2 Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages.

20

-

-

... More
23.26.3 Supply and erection of shock restoration chart in glass frame.

25

-

-

... More
EARTHING AND LIGHTENING ARRESTOR HSR 24.1 24.1.1 Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.

32

-

-

... More
24.1.2 Extra for using salt and char coal/coke for pipe earth electrode as required.

32

-

-

... More
24.1.3 Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.

30

-

-

... More
24.1.4 Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.

32

-

-

... More
24.1.5 Extra for charcoal or coke and salt for G. I. plate or copper plate earth electrode.

62

-

-

... More
24.1.7 Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.

300

-

-

... More
24.1.8 Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.

320

-

-

... More
24.1.9 Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.

320

-

-

... More
24.1.10 Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.

285

-

-

... More
24.1.11 Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required.

720

-

-

... More
24.1.14 Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. staples of same size.

840

-

-

... More
24.1.16 Supply and erection of 25mm dia 1.5 metre long lightning GI. tube rod tapered into a point at the top with 16cm x 16cm x 3mm thick G.I. base plate and necessary nuts and bolts with washers.

220

-

-

... More
24.1.17 Providing and fixing testing joints made of 20mm x 3mm thick G.I. strips 125 mm long with 4 nos. G.I. bolts and nuts with washers complete.

75

-

-

... More
LT CABLE HSR 24.2 24.2.4 Laying of underground cable in pipe /existing open/closed trench etc as 24.2.4.3) 50 Sq mm to 150 sqmm 2 to 4 Core

590

-

-

... More
Non Schedule items Supply and erection of Air insulated compact rising main having enclosure made up of 1.6 mm GI sheet duly powder coated, 4P aluminium bus bars in convenient section with spot of F insulator at suitable distance suitable for 415 V 50Hz AC including fire barriers, bracket and two runs of external aluminium earthing(Consider current density of 130 amp. P/Sqcm complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. . (C&S/ Siemens/ L&T). 200 A/10KA

120

-

-

... More
250 A/15KA

35

-

-

... More
315 A/25KA

122

-

-

... More
400 A/30KA

58

-

-

... More
500 A/35KA

16

-

-

... More
630 A/50KA

32

-

-

... More
Supply and erection of End feed unit Box with provision MCCB(Without MCCB Cost) complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. . (C&S/ Siemens/ L&T). 200 Amp.

12

-

-

... More
250 Amp.

3

-

-

... More
315 Amp.

7

-

-

... More
400 Amp.

4

-

-

... More
500 Amp.

1

-

-

... More
630 Amp.

2

-

-

... More
Supply and erection of TPN Tap Boxes with 4 Pole MCCB 25 KA (Without MCCB Cost) complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. . (C&S/ Siemens/ L&T). 125 Amp.

12

-

-

... More
100 Amp.

36

-

-

... More
63 Amp.

160

-

-

... More
Supply of Sandwich Rising Mains of 4 Pole (3 Ph 4 Wire system) of Aluminium busbars with integral G.I. housing as earth, Bus Trunking enclosure shall be made of 1.6mm thick Electro Galvanized GI sheet, degree of protection IP54, multi layer insulation of Class-F, Temperature rise as per IEC 61439 - 1&6. Including 2 runs of external Aluminium earthing, End cover, Vertical supports, Spring Hanger, Rigid Hanger & Two plug in point provision at every floor (Consider Current Density 130A/Sqmm) (Consider current density of 130 amp. P/Sqcm complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. . (C&S/ Siemens/ L&T). 1250 Amp.

52

-

-

... More
1600 Amp.

24

-

-

... More
Supply and erection of End feed unit Box with provision MCCB for Sandwich Rising Mains (Without MCCB Cost) complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. . (C&S/ Siemens/ L&T). 1250 Amp.

4

-

-

... More
1600 Amp.

2

-

-

... More
Supply and erection of TPN Tap Boxes with 4 Pole MCCB 25 KA for Sandwich Rising Mains (Without MCCB Cost) complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. . (C&S/ Siemens/ L&T). 125 Amp.

7

-

-

... More
100 Amp.

7

-

-

... More
63 Amp.

15

-

-

... More
Supply and erection of suitable MCCB designed for Compact Air Insulated rising main and sandwich rising main complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. . (C&S/ Siemens/ L&T). 1250 Amp. 4P 50 M.P. MCCB

4

-

-

... More
1600 Amp. 4P 50 M.P. MCCB

2

-

-

... More
Supply and erection of Double door sheet, steel superline/ Powerline/ Loadline TPN Vertical distribution boards suitable for TP/ FP veritcal MCCBs 25 KA MCCB upto 125 amp as incomer (but without cost of MCCBs) fitted with busbars, Neutral links,& Blanking plates complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (C&S/ Indoasian/Siemens). 4 Way Vertical

18

-

-

... More
8 Way Vertical

25

-

-

... More
12 Way Vertical

9

-

-

... More
Supply and erection of Double door sheet, steel superline/ Powerline/ Loadline TPN Vertical distribution boards suitable for TP/ FP veritcal MCCBs 25 KA MCCB upto 250 amp as incomer (but without cost of MCCBs) fitted with busbars, Neutral links,& Blanking plates complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (C&S/ Indoasian/Siemens). 8 Way Vertical

6

-

-

... More
12 Way Vertical

25

-

-

... More
S/E of RCCB 63 Amp.100mA Sensitivity ISI/CE marked as per IS/IEC 12640-1 with degree of protection IP 20, INC 10KA operation voltage 240/415 Volt AC 50hz of Indoasian make and equivallant make C&S/ L&T/Schinder including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work.

26

-

-

... More
Supply of Under Ground LT Power Cables of Aluminium Conductor complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Make:- Havell's/ Grandlay/ RR Kabel. 50 Sqmm 3.5 Core Ard. Cable

60

-

-

... More
120 Sqmm 3.5 Core Ard. Cable

530

-

-

... More
150 Sqmm 3.5 Core Ard. Cable

690

-

-

... More
For Lift S/I/E/T/C of 10 persons lift (680 Kgs. Weight) having speed @ 1.0 meters per second to travel from Basement/ ground and Three Nos. upperFloors with 5 stops, 5 openings (Basement- Ground -3rd Floor) with ARD system and Full Height Infrared safety and as per technical specifications attached complete including cost and erection of extra steel items if required, upto the entire satisfaction of the Engineer-in-Charge. Kone/ OTIS/ Schindler/ Orbis/ Mitshbishi/ Johnson. (MR)

1

-

-

... More
S/I/E/T/C of 10 persons lift (680 Kgs. Weight) having speed @ 1.0 meters per second to travel from Basement/ ground and Six Nos. upperFloor with 8 stops, 8 openings ( Basement- Ground -6th Floor) with ARD system and Full Height Infrared safety and as per technical specifications attached complete including cost and erection of extra steel items if required, upto the entire satisfaction of the Engineer-in-Charge. Kone/ OTIS/ Schindler/ Orbis/ Mitshbishi/ Johnson (MR)

6

-

-

... More
S/I/E/T/C of 13 persons lift (884 Kgs. Weight) having speed @ 1.0 meters per second to travel from Ground and Four Nos. upperFloors with 5 stops, 5 openings (Basement- Ground -4th Floor) with ARD system and Full Height Infrared safety and as per technical specifications attached complete including cost and erection of extra steel items if required, upto the entire satisfaction of the Engineer-in-Charge. Kone/ OTIS/ Schindler/ Orbis/ Mitshbishi/ Johnson.

3

-

-

... More
S/I/E/T/C of 13 persons lift (884 Kgs. Weight) having speed @ 1.0 meters per second to travel from Basement/ ground and Six Nos. upperFloor with 8 stops, 8 openings ( Basement- Ground -6th Floor) with ARD system and Full Height Infrared safety and as per technical specifications attached complete including cost and erection of extra steel items if required, upto the entire satisfaction of the Engineer-in-Charge. Kone/ OTIS/ Schindler/ Orbis/ Mitshbishi/ Johnson (MR)

4

-

-

... More
S/I/E/T/C of 20 persons lift (1360 Kgs. Weight) having speed @ 1.0 meters per second to travel from Basement/ ground and Three Nos. upperFloors with 5 stops, 5 openings (Basement- Ground -3rd Floor) with ARD system and Full Height Infrared safety and as per technical specifications attached complete including cost and erection of extra steel items if required, upto the entire satisfaction of the Engineer-in-Charge. Kone/ OTIS/ Schindler/ Orbis/ Mitshbishi/ Johnson.(MR)

2

-

-

... More
S/I/E/T/C of 20 persons lift (1360 Kgs. Weight) having speed @ 1.0 meters per second to travel from Basement/ ground and Six Nos. upperFloor with 8 stops, 8 openings ( Basement- Ground -6th Floor) with ARD system and Full Height Infrared safety and as per technical specifications attached complete including cost and erection of extra steel items if required, upto the entire satisfaction of the Engineer-in-Charge. Kone/ OTIS/ Schindler/ Orbis/ Mitshbishi/ Johnson.(MR)

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.