Public Works Department Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date1 Aug 2024
Closing Date12 Aug 2024
Tender Amount₹ 4,82,86,144 
Notes
Download

Costs

  • EMD

    ₹ 9,65,720
  • Document Cost

    ₹ 15,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
[24.1.12]EARTHING AND LIGHTENING ARRESTOR 12. Supplying and laying 6 S.W.G G.I. wire at 0.50 m below ground level from earth electrode including thimbles, soldering etc. as required.

100

-

-

... More
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.

2

-

-

... More
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.

2

-

-

... More
[24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.

75

-

-

... More
[24.4.7.2]STREET LIGHT 7.2. Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40 mm dia

400

-

-

... More
[25.1.1]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 1. 300mm dia.

25

-

-

... More
[25.1.10]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 10. 40mm dia.

400

-

-

... More
[25.1.2]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 2. 250 mm dia

225

-

-

... More
[25.1.3]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 3. 200mm dia.

1

-

-

... More
[25.1.6]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 6. 100mm dia.

16

-

-

... More
[25.1.7]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 7. 80mm dia.

100

-

-

... More
[25.1.8]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 8. 65mm dia.

100

-

-

... More
[25.1.9]Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 9. 50mm dia.

300

-

-

... More
[25.2]Extra for Supplying and fixing of insulation on following nominal dia pipes with FR quality expanded polystyrene moulded pipe section of density 20 kg/cum after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500 g polythene faced hessian and then applying 0.6 mm aluminium sheet cladding complete with felt strip at joints repairing etc. as per specifications and as required complete in all respect..

1970

-

-

... More
[25.3.2]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 2. 250 mm dia

6

-

-

... More
[25.3.3]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 3. 200mm dia.

8

-

-

... More
[25.3.4]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 4. 150mm dia.

2

-

-

... More
[25.3.5]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 5. 125mm dia.

1

-

-

... More
[25.3.6]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 6. 100mm dia.

13

-

-

... More
[25.3.7]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 7. 80mm dia.

22

-

-

... More
[25.3.8]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 8. 65mm dia.

2

-

-

... More
[25.3.9]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 9. 50 mm dia.

2

-

-

... More
[25.4.1]Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 1. 200mm dia.

2

-

-

... More
[25.4.4]Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 4. 100mm dia.

2

-

-

... More
[25.5.1]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 1. 200mm dia.

2

-

-

... More
[25.5.4]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 4. 100mm dia.

7

-

-

... More
[25.5.5]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 5. 80mm dia.

11

-

-

... More
[25.5.6]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 6. 65mm dia.

1

-

-

... More
[25.5.7]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 7. 50mm dia.

1

-

-

... More
[25.6.1]Supplying, fixing, testing and commissioning o STRAINER flanged end and PN 16 pressure rating as specified. 1. 200mm dia.

2

-

-

... More
[25.6.4]Supplying, fixing, testing and commissioning o STRAINER flanged end and PN 16 pressure rating as specified. 4. 100mm dia.

2

-

-

... More
[25.6.5]Supplying, fixing, testing and commissioning o STRAINER flanged end and PN 16 pressure rating as specified. 5. 80mm dia.

8

-

-

... More
[25.6.6]Supplying, fixing, testing and commissioning o STRAINER flanged end and PN 16 pressure rating as specified. 6. 65mm dia.

1

-

-

... More
[25.6.7]Supplying, fixing, testing and commissioning o STRAINER flanged end and PN 16 pressure rating as specified. 7. 50mm dia.

1

-

-

... More
[25.7.1]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 1. Thickness 0.63 mm sheet

1000

-

-

... More
[25.7.2]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 2. Thickness 0.80 mm sheet

50

-

-

... More
[25.7.3]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 3. Thickness 1.00 mm sheet

50

-

-

... More
Earth Station as per ISI Specification.

1

-

-

... More
Supply and Fixing of 3C x 1.5 Sqmm Providing and Fixing of control cable of shielded and analyed tinned copper for inter locking. complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

200

-

-

... More
FCU:- Supply, installation, testing and commissioning of 1.5 TR. 600 CFM 7 mm of WC 3 Deep 10 Level factory fabricated Double Skin Chilled Water Air- handling unit horizontal type fabricated out of extruded aluminium section consisting with 0.63 mm pre-plasticized/pre-coated Galvanized steel sheet outside and 0.63 mm plain aluminium sheet inside with blower, blower section and Blower shall be DIDW forward / Backward Curved blade from and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, Multi Row deep cooling coil made of Aluminium finned Copper tube with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% , stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. The AHU panels shall be insulated with 25 plus 2 mm thick and 38 Kg/m³ density PU foam. The motor and blower assembly shall be mounted on Aluminium extruded section. The complete AHU/FCU shall conform to standard specification complete in all respect upto entire satisfaction of Engineer in charge of work. Make : as per attached list.

45

-

-

... More
Providing and fixing in position the 25 mm dia water flow switch as per complete in all respect upto entire satisfaction of Engineer in charge of work. Make : as per attached list.

2

-

-

... More
Supply, installation, testing and commissioning of 8 TR 3200 65 mm 6 Row 5 Microns factory fabricated Double Skin Chilled Water Air- handling unit horizontal type fabricated out of extruded aluminium section consisting with 0.63 mm pre-plasticized/pre-coated Galvanized steel sheet outside and 0.63 mm plain aluminium sheet inside with blower, blower section and Blower shall be DIDW forward / Backward Curved blade from and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, Multi Row deep cooling coil made of Aluminium finned Copper tube with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% , stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. The AHU panels shall be insulated with 25 plus 2 mm thick and 38 Kg/m³ density PU foam. The motor and blower assembly shall be mounted on Aluminium extruded section. The complete AHU/FCU shall conform to standard specification complete in all respect upto entire satisfaction of Engineer in charge of work. Make : as per attached list.

6

-

-

... More
Supply, installation, testing and commissioning of 5.5 TR 2500 40mm 4 Row 10 Microns factory fabricated Double Skin Chilled Water Air- handling unit horizontal type fabricated out of extruded aluminium section consisting with 0.63 mm pre-plasticized/pre-coated Galvanized steel sheet outside and 0.63 mm plain aluminium sheet inside with blower, blower section and Blower shall be DIDW forward / Backward Curved blade from and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, Multi Row deep cooling coil made of Aluminium finned Copper tube with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% , stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. The AHU panels shall be insulated with 25 plus 2 mm thick and 38 Kg/m³ density PU foam. The motor and blower assembly shall be mounted on Aluminium extruded section. The complete AHU/FCU shall conform to standard specification complete in all respect upto entire satisfaction of Engineer in charge of work. Make : as per attached list.

6

-

-

... More
Providing and fixing in position the following 50 mm dia three way valves for Air Handling units complete with necessary cooling / heating thermostat and actuator complete in all respect upto entire satisfaction of Engineer in charge of work. Make : as per attached list.

2

-

-

... More
FCU:- Supply, installation, testing and commissioning of 3.0 TR. 1200 CFM 7 mm of WC 3 Deep 10 Level factory fabricated Double Skin Chilled Water Air- handling unit horizontal type fabricated out of extruded aluminium section consisting with 0.63 mm pre-plasticized/pre-coated Galvanized steel sheet outside and 0.63 mm plain aluminium sheet inside with blower, blower section and Blower shall be DIDW forward / Backward Curved blade from and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, Multi Row deep cooling coil made of Aluminium finned Copper tube with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% , stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. The AHU panels shall be insulated with 25 plus 2 mm thick and 38 Kg/m³ density PU foam. The motor and blower assembly shall be mounted on Aluminium extruded section. The complete AHU/FCU shall conform to standard specification complete in all respect upto entire satisfaction of Engineer in charge of work. Make : as per attached list.

24

-

-

... More
Providing and fixing in position the following 32mm dia MS `C` class pipes, cut to required length and installed with welded joints, providing and fixing all necessary fittings such as bends, elbows, tees, reducers, flanges, sockets etc. Chilled water piping shall be insulated with 50 mm thick EPS Pipe Section (TF Quality) covered with 2 layers of sand cement plaster each layer of 8 mm for exposed piping or 26 SWG Aluminium cladding over piping for indoor installation complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

500

-

-

... More
Providing and fixing in position the following 65 mm dia three way valves for Air Handling units complete with necessary cooling / heating thermostat and actuator complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

7

-

-

... More
Providing and fixing in position mercury-in-glass filled industrial thermometers complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

36

-

-

... More
Providing and fixing in position industrial type pressure gauges having dial size 100 mm complete with syphon and cock complete in all respect upto entire satisfaction of Engineer in charge of work. .Make as per attached list.

36

-

-

... More
Providing and fixing in position the following 25mm dia MS `C` class pipes, cut to required length and installed with welded joints, providing and fixing all necessary fittings such as bends, elbows, tees, reducers, flanges, sockets etc. Chilled water piping shall be insulated with 50 mm thick EPS Pipe Section (TF Quality) covered with 2 layers of sand cement plaster each layer of 8 mm for exposed piping or 26 SWG Aluminium cladding over piping for indoor installation complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

500

-

-

... More
Pressurized Expansion Tank cap 500 ltrs insulated with 50mm thick EPS (Expanded Polystyrene) slab covered with Vapour Barrier, Chicken Wire Mesh and Finished with Sand Cement Plaster with overflow valve, float valve as specified by Engineer-in-charge. Make as per attached list.

1

-

-

... More
SITC of 32 mm dia Ball Valves complete in all respect upto entire satisfaction of Engineer in charge of work. make as per attached list.

20

-

-

... More
Providing and fixing in position the 250mm dia Check (Non return) valves (PN-16) as per specifications complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

2

-

-

... More
SITC of 25 mm dia (DE-scaling valves) Ball Valves complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

4

-

-

... More
Supply , installation , testing and commissioning of Basement ventilation Jet Fans - 700 CFM with SP 30 mmwg, with suitable motor and drive assembly, with all accessories and fire rated flexible connections, mounting frame hangers etc. Motor shall be suitable for 415 V plus /- 10%, 3 phase, 4 wire, 50 plus /- 3% Hzs, electric supply complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

12

-

-

... More
Providing and fixing of duct insulation with 25mm thick closed cell nitrile rubber sheet as per specs complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list...

1000

-

-

... More
Supplying and fixing of powder coated extruded aluminium return Air Grills / diffusers without volume control dampers as per specifications, Make as per attached list.

250

-

-

... More
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Make as per attached list.

15

-

-

... More
SITC of Actuators Motor for Fire Dampers complete in all respect upto entire satisfaction of engineer in charge. Make as per attached list.

9

-

-

... More
Supply, installation, testing and commissioning of End Suction Back pull out, flexible coupling with coupling guard centrifugal type Chilled Water pumping set with BZ/CF-8 ASTM #A351 Impeller , Casing/Volute - Cast Iron ASTM #159, Shaft – SS 416 complete with IE3 motor, base frame and motor should be non-overloading type. Pumps efficiency should be more then 85%. The pump motor shall be suitable for 4 pole, 415 Volts ± 10%, 50 cycles, 3 phase power supply. Apart from this Pumps should be mandatory along with wireless optimyze monitoring device mounted over Pump set which is suitable to measure changes on vibration in three axis and temperature in pumps set. operating parameters as Pumping set with bronze impeller (1 Working plus 1 std by), Cap 840 USGPM (53.5 LPS), HEAD 24 meter, complete in all respect upto entire satisfaction of Engineer in charge of work: Make as per attached list.

2

-

-

... More
Supply, installation, testing and commissioning hot water generator arranged in steps of capacity 350 KW (1Working plus 0 Std By) complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

1

-

-

... More
Supply, installation, testing and commissioning of induced draft cooling towers of cap 425 TR. Each tower shall be complete with distribution system, fillings, louvers, Hot dipped galvanized ladder, axial flow fan and motor. Motor (IP:55) shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase power supply. The Cooling Tower shall be complete in all respect capacity of each Cooling tower shall be as follows: Capacity: To Cool 1400 USGPM of water at parameters indicated above, complete in all respect upto entire satisfaction of Engineer in charge of work Make as per attached list.

2

-

-

... More
Supply, installation, testing and commissioning of AHU Cap Static pressure Cooling Coil filteration FM 30 TR 12000 CFM 65 mm 6 Row 5 Microns factory fabricated Double Skin Chilled Water Air- handling unit horizontal type fabricated out of extruded aluminium section consisting with 0.63 mm pre-plasticized/pre-coated Galvanized steel sheet outside and 0.63 mm plain aluminium sheet inside with blower, blower section and Blower shall be DIDW forward / Backward Curved blade from and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, Multi Row deep cooling coil made of Aluminium finned Copper tube with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% , stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. The AHU panels shall be insulated with 25 plus 2 mm thick and 38 Kg/m³ density PU foam. The motor and blower assembly shall be mounted on Aluminium extruded section. The complete AHU/FCU shall conform to standard specification complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

1

-

-

... More
Supply, installation, testing and commissioning of AHU Cap Static pressure Cooling Coil filtration FM 12 TR 4800 CFM 65 mm 6 Row 5 Microns factory fabricated Double Skin Chilled Water Air- handling unit horizontal type fabricated out of extruded aluminium section consisting with 0.63 mm pre-plasticized/pre-coated Galvanized steel sheet outside and 0.63 mm plain aluminium sheet inside with blower, blower section and Blower shall be DIDW forward / Backward Curved blade from and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, Multi Row deep cooling coil made of Aluminium finned Copper tube with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% , stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. The AHU panels shall be insulated with 25 plus 2 mm thick and 38 Kg/m³ density PU foam. The motor and blower assembly shall be mounted on Aluminium extruded section. The complete AHU/FCU shall conform to standard specification complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

2

-

-

... More
Supply, installation, testing and commissioning of AHU Cap Static pressure Cooling Coil filtration FM 10 TR 4000 CFM 65 mm 6 Row 5 Microns factory fabricated Double Skin Chilled Water Air- handling unit horizontal type fabricated out of extruded aluminium section consisting with 0.63 mm pre-plasticized/pre-coated Galvanized steel sheet outside and 0.63 mm plain aluminium sheet inside with blower, blower section and Blower shall be DIDW forward / Backward Curved blade from and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, Multi Row deep cooling coil made of Aluminium finned Copper tube with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% , stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. The AHU panels shall be insulated with 25 plus 2 mm thick and 38 Kg/m³ density PU foam. The motor and blower assembly shall be mounted on Aluminium extruded section. The complete AHU/FCU shall conform to standard specification complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

5

-

-

... More
Ceiling Suspended Units : Supply, installation, testing and commissioning of 15 TR 6000 CFM 65 mm 6 Row 5 Microns factory fabricated Double Skin Chilled Water Air- handling unit horizontal type fabricated out of extruded aluminium section consisting with 0.63 mm pre-plasticized/pre-coated Galvanized steel sheet outside and 0.63 mm plain aluminium sheet inside with blower, blower section and Blower shall be DIDW forward / Backward Curved blade from and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, Multi Row deep cooling coil made of Aluminium finned Copper tube with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% , stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. The AHU panels shall be insulated with 25 plus 2 mm thick and 38 Kg/m³ density PU foam. The motor and blower assembly shall be mounted on Aluminium extruded section. The complete AHU/FCU shall conform to standard specification complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

4

-

-

... More
Ceiling Suspended Units : Supply, installation, testing and commissioning of 12 TR 4800 CFM 65 mm 6 Row 5 Microns factory fabricated Double Skin Chilled Water Air- handling unit horizontal type fabricated out of extruded aluminium section consisting with 0.63 mm pre-plasticized/pre-coated Galvanized steel sheet outside and 0.63 mm plain aluminium sheet inside with blower, blower section and Blower shall be DIDW forward / Backward Curved blade from and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, Multi Row deep cooling coil made of Aluminium finned Copper tube with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% , stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. The AHU panels shall be insulated with 25 plus 2 mm thick and 38 Kg/m³ density PU foam. The motor and blower assembly shall be mounted on Aluminium extruded section. The complete AHU/FCU shall conform to standard specification complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

7

-

-

... More
Ceiling Suspended Units : Supply, installation, testing and commissioning of 10 TR 4000 CFM 65 mm 6 Row 5 Microns factory fabricated Double Skin Chilled Water Air- handling unit horizontal type fabricated out of extruded aluminium section consisting with 0.63 mm pre-plasticized/pre-coated Galvanized steel sheet outside and 0.63 mm plain aluminium sheet inside with blower, blower section and Blower shall be DIDW forward / Backward Curved blade from and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, Multi Row deep cooling coil made of Aluminium finned Copper tube with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% , stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. The AHU panels shall be insulated with 25 plus 2 mm thick and 38 Kg/m³ density PU foam. The motor and blower assembly shall be mounted on Aluminium extruded section. The complete AHU/FCU shall conform to standard specification complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

12

-

-

... More
Supply, installation, testing and commissioning of End Suction Back pull out, flexible coupling with coupling guard centrifugal type Condenser Water pumping set with BZ/CF-8 ASTM #A351 Impeller , Casing/Volute - Cast Iron ASTM #159, Shaft – SS 416 complete with IE3 motor, base frame and motor should be non-overloading type. Pumps efficiency should be more then 85%. The pump motor shall be suitable for 4 pole, 415 Volts ± 10%, 50 cycles, 3 phase power supply. Apart from this Pumps should be mandatory along with wireless optimyze monitoring device mounted over Pump set which is suitable to measure changes on vibration in three axis and temperature in pumps set. operating parameters Pumping set with bronze impeller (1 Working plus 1 std by), Cap 1400 USGPM (90 LPS), HEAD 28-32 meter Complete in all respect upto entire satisfaction of Engineer in Charge of work: Make as per attached list.

2

-

-

... More
Supply, installation, testing and commissioning of 4 TR 1600 CFM 40 mm 4 Row 10 Microns factory fabricated Double Skin Chilled Water Air- handling unit horizontal type fabricated out of extruded aluminium section consisting with 0.63 mm pre-plasticized/pre-coated Galvanized steel sheet outside and 0.63 mm plain aluminium sheet inside with blower, blower section and Blower shall be DIDW forward / Backward Curved blade from and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, Multi Row deep cooling coil made of Aluminium finned Copper tube with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% , stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. The AHU panels shall be insulated with 25 plus 2 mm thick and 38 Kg/m³ density PU foam. The motor and blower assembly shall be mounted on Aluminium extruded section. The complete AHU/FCU shall conform to standard specification complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

25

-

-

... More
FCU:- Supply, installation, testing and commissioning of 2.0 TR. 800 CFM 7 mm of WC 3 Deep 10 Level factory fabricated Double Skin Chilled Water Air- handling unit horizontal type fabricated out of extruded aluminium section consisting with 0.63 mm pre-plasticized/pre-coated Galvanized steel sheet outside and 0.63 mm plain aluminium sheet inside with blower, blower section and Blower shall be DIDW forward / Backward Curved blade from and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, Multi Row deep cooling coil made of Aluminium finned Copper tube with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% , stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. The AHU panels shall be insulated with 25 plus 2 mm thick and 38 Kg/m³ density PU foam. The motor and blower assembly shall be mounted on Aluminium extruded section. The complete AHU/FCU shall conform to standard specification complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

16

-

-

... More
Supply, installation, testing and commissioning of AHU Cap Static pressure Cooling Coil filtration FM 25 TR 10000 CFM 65 mm 6 Row 5 Microns factory fabricated Double Skin Chilled Water Air- handling unit horizontal type fabricated out of extruded aluminium section consisting with 0.63 mm pre-plasticized/pre-coated Galvanized steel sheet outside and 0.63 mm plain aluminium sheet inside with blower, blower section and Blower shall be DIDW forward / Backward Curved blade from and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, Multi Row deep cooling coil made of Aluminium finned Copper tube with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% , stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. The AHU panels shall be insulated with 25 plus 2 mm thick and 38 Kg/m³ density PU foam. The motor and blower assembly shall be mounted on Aluminium extruded section. The complete AHU/FCU shall conform to standard specification complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

1

-

-

... More
FCU:- Supply, installation, testing and commissioning of 2.5 TR. 1000 CFM 7 mm of WC 3 Deep 10 Level factory fabricated Double Skin Chilled Water Air- handling unit horizontal type fabricated out of extruded aluminium section consisting with 0.63 mm pre-plasticized/pre-coated Galvanized steel sheet outside and 0.63 mm plain aluminium sheet inside with blower, blower section and Blower shall be DIDW forward / Backward Curved blade from and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, Multi Row deep cooling coil made of Aluminium finned Copper tube with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% , stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. The AHU panels shall be insulated with 25 plus 2 mm thick and 38 Kg/m³ density PU foam. The motor and blower assembly shall be mounted on Aluminium extruded section. The complete AHU/FCU shall conform to standard specification complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

3

-

-

... More
Providing and fixing in position the 250mm dia balancing valves (PN-16) as per specifications: complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

2

-

-

... More
Supplying and fixing of Fresh air intake louvers with bird screen and dampers (Aluminium extruded only). Make as per attached list..

5

-

-

... More
Supply , installation , testing and commissioning of Axial Flow Fan - 5900 CFM SP 25 mmwg, with suitable motor and drive assembly, with all accessories and fire rated flexible connections, mounting frame hangers etc. Motor shall be suitable for 415 V plus /- 10%, 3 phase, 4 wire, 50 plus /- 3% Hzs, electric supply complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

4

-

-

... More
SITC of Acousting Insulation of Duct from inside with covered 10 mm open cell insulation complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list. .

50

-

-

... More
Supplying and fixing of powder coated extruded aluminium Supply Air Grills / diffusers with aluminium volume control dampers as per specifications. complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

250

-

-

... More
SITC of `Main A.C. Panel-P1- main panel boards made of 1.6/2.0 mm thick steel sheet duly powder coated complete with voltmeter, ammeter, indicating lights, selector switch, incoming/ outgoing isolators, current operated single phase preventor, CTS contactors, A/M Switch for remote controls operation complete as per specifications and drawings and as required. Incomer, 1 No. 1200 Amps ACB 4 Pole incoming (MDO) 65 KA, 1 No. 1200 Amps aluminium conductor bus bar duly sleeved, 1 No. electronic energy meter with CTs., 1 No. Ammeter with ASS and CTs., 1 No. voltmeter with VSS., 3 Nos. phase indicating lamps, Outgoing, 2 No. 400-500 Amps TP plus NL MCCB MDO 50 KA outgoing for 350 TR chillers, 1 Nos. 630A ACB TP plus NL MDO 50 KA outgoing for 300 KW Hot water generator, 2 Nos. 63-100 Amps 25 KA MCCB TP plus NL outgoing for condenser water pumps with 15HP motor (Chiller Condenser Water Pump), 2 No. 63 Amps MCCB 25 KA outgoing for Cooling Tower with 7.5kw x 2 nos motor, 2 Nos. 63-100 Amps TP MCCB 25 KA outgoing for chilled water pumps with 15 HP motor, 1 Nos. 100 Amps MCCB TP plus NL outgoing for spare, 2 Nos. automatic type star delta starter for water pumps (15HP), 2 No. Automatic Type DOL Starter for Cooling Tower (7.5 HPx 2Nos ), 2 No. Automatic Type Star Delta Starter for Condenser Water Pump (15HP), All starters shall have following accessories :, 1 No. overload relay, 1 No. Ammeter with ASS and CTs, `1 No. single phase preventer, 2 Nos. ON/OFF indicating lights, 2 Nos. ON/OFF push buttons, Powder Coated Enclosure made out of TATA/SAIL/ESSAAR make CRCA sheet having 2 mm for load bearing surfaces and 1.6 mm for non load bearing surfaces ,duly processed powder coated having Siemens grey colour. Hardware (PVC Channels/MCB Channels/Fibre-Glass/Gaskets/Sleeves/nuts/Bolts/washers/cooling fans/etc), Complete Wiring inclusive of thimbles, etc Note: ACB incomer to be 4 pole with O/L,EF,SC, in the main panel with display (V/A) ACB, MCCB Make as per attached, MCCB upto 100 Amps to be 25 KA with ICU=ICS=100%, MCCB above 100 Amps to be 35/36 KA with ICU=ICS=100%, Contactors, complete in all respect upto entire satisfaction of Engineer in Charge of work: Make as per attached list.

1

-

-

... More
SITC of Sub Panel :- P2 for AHUs Wall mounted sub panel boards for AHUs with starter inter connections, Current operated single phase preventors A/M switch etc as per specifications and drawings as required.1 No incoming 100 Amps 4 pole TP plus NL MCB, 1 No star delta starter for motor, 3 Nos indication lights, 2 Nos Push Buttons, complete in all respect upto entire satisfaction of Engineer in Charge of work as per attached list.

30

-

-

... More
SITC if Weather proof isolator for cooling tower Outdoor weather proof switch box of continuous welded construction, fabricated out of 2 mm thick GI sheet complete with water tight gasket with front openable and lockable door including earthing, painting glands, danger boards etc. Suitable for mounting on MS angle frame consisting of revelant specification and drawings 100 Amps TP plus NL isolators for cooling tower near cooling tower complete the job in all respect up to the entire satisfaction of Engineer in Charge of work. Make as per attached list. .

2

-

-

... More
Supply and Fixing of 240 Sqmm 3.5 Core Aluminium PVC insulated armoured aluminium conductor cables 1100 Volts grade from main panel board to various equipment`s through walls/ ceiling with appropriate clamps , cable termination and fixing arrangement, cable trays etc as per specs and drawings complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list...

50

-

-

... More
Supply and Fixing of 25 Sqmm 3.5 Core Aluminium PVC insulated armoured aluminium conductor cables 1100 Volts grade from main panel board to various equipment`s through walls/ ceiling with appropriate clamps , cable termination and fixing arrangement, cable trays etc as per specs and drawings complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

55

-

-

... More
Supply and Fixing of 10 Sqmm 4 Core Aluminium PVC insulated armoured aluminium conductor cables 1100 Volts grade from main panel board to various equipment`s through walls/ ceiling with appropriate clamps , cable termination and fixing arrangement, cable trays etc as per specs and drawings complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

150

-

-

... More
Supply and Fixing of 4C x 2.5 Sqmm Providing and Fixing of control cable of shielded and analyed tinned copper for inter locking. complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

400

-

-

... More
Providing and fixing of 250mm dia Y strainer as per specifications of complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

2

-

-

... More
Supply , installation , testing and commissioning of Jet fans of 10700 CFM with SP 65 mmwg Dia 300-400 mm, with suitable motor and drive assembly, with all accessories and fire rated flexible connections, mounting frame hangers etc. Motor shall be suitable for 415 V plus /- 10%, 3 phase, 4 wire, 50 plus /- 3% Hzs, electric supply complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

2

-

-

... More
Suuplying, Installation, Testing and Commissioning of floor-mounted desk type Control Console in A/c plant room containing various indications and controls for the A.C. system comprising of 2 Nos. chilling machine, 4 Nos. pumps, 2 Nos. cooling tower, 15 Nos AHU/CSU with test push buttons facility. The panel shall be fabricated from minimum 1.633 thick M.S. Powder coated sheet of approved design. The A.C. module of the Central Control shall have the following accessories: Status indication (ON, OFF) for each compressor for each chilling machine and all pumps. Push Buttons and Indication lamps for remote start and stop and status indication for each of the AHUs. Push Buttons and Indication lamps for remote start and stop and status indication(ON, OFF and Fault) for each of the 3 Nos. Cooling Tower motors and low level indication for each of 3Nos. cooling tower. Hooter and Flashing lamps to indicate operation of any safety/shut down with necessary contractors, accept, reset and test push buttons complete as per specifications to complete the job in all respect up to the entire satisfaction of Engineer in Charge of work. Make as per attached list.

1

-

-

... More
Supply and Fixing of 16 Sqmm 4 Core Aluminium PVC insulated armoured aluminium conductor cables 1100 Volts grade from main panel board to various equipment`s through walls/ ceiling with appropriate clamps , cable termination and fixing arrangement, cable trays etc as per specs and drawings complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

75

-

-

... More
Supply and Fixing of 4 Sqmm 4 Core Aluminium PVC insulated armoured aluminium conductor cables 1100 Volts grade from main panel board to various equipment`s through walls/ ceiling with appropriate clamps , cable termination and fixing arrangement, cable trays etc as per specs and drawings complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

60

-

-

... More
Supply and Fixing of 6 Sqmm 4 Core Aluminium PVC insulated armoured aluminium conductor cables 1100 Volts grade from main panel board to various equipment`s through walls/ ceiling with appropriate clamps , cable termination and fixing arrangement, cable trays etc as per specs and drawings complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

90

-

-

... More
Providing and fixing in position the 25 mm dia automatic purging valves complete in all respect upto entire satisfaction of Engineer in charge of work. Make as per attached list.

5

-

-

... More
Water Cooled Chilling Unit:- Supply, Installation, testing and commissioning of Water Cooled Screw type chilling unit of 350 TR actual capacity with company fitted VFD at the parameters indicated below complete with Semi hermitic/ hermetic Helical Rotary Mono/twin Screw with single/ two number independent refrigerant circuit with single/multiple compressor, TERC motor, factory insulated cooler, Water cooled condenser, vibration, isolators, integral refrigerant piping and wiring, flow switches at chiller and condenser outlets, first charge of refrigerant and lubricant, microprocessor based control panel, accessories as required. Motor shall be suitable for 415 plus - 10% V, 50 Hz, 3 ph AC supply as per specifications with all labour and petty material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work, Cooler:- Chilled Water in: 12° C (54° F) Chilled water out 7.2° C (44° F) Chilled water flow rate: 840 USGPM Fouling Factor:- 0.0005 FPS Condenser :- Condenser water in :- 32.22° C Condenser water out : 36.44° C Condenser water flow rate: 1400 USGPM Fouling Factor :- 0.001 FPS COP at AHRI conditions shall be 5.9 minimum IKW/TR shall be 0.71 at design conditions) and NPLV shall be 0.39 KW/TR. Make as per attached list.

2

-

-

... More
-Pdg. Minor Civil work i.e foundation of Chiller, Pump ,Set, Cooling tower, Hot water generator, making holes in brick wall, work for ducting, piping including repair with mixture of sand ,and cement with all labour and petty material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of work

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.