Public Works Department Tender

... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Public Works Department - PWD Tender

Works
Security and Emergency Services
Eprocure
Opening Date13 Mar 2024
Closing Date22 Mar 2024
Tender Amount₹ 20,86,646 
Notes
Download

Costs

  • EMD

    ₹ 41,740
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SITC of addressable multi sensor smoke detector including mounting base with RED LED should blink in normal conditions and LED should be continues in fire conditions complete as required with inbuilt Isolators as per NFPA 72 style 7 wiring requirements for maintaining operational availability of all elements in the loop in the eventof a short circuit and to meet style 7 requirements: Compensation feature and Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel-current and average values. Detector should have IP30 or better protection rating. Shall be UL/EN/VDS certification. Detectors should have Inbuilt Isolators. Make: Eaton, Bosch, Siemens)

15

-

-

... More
Supply erection testing and commissioning of addressable Heat detector with fixed and rate of raise 60 degree feature and minimum 70 degree including mounting base with RED LED should blink in normal conditions and LED should be continues in fire conditions. etc complete as required. Each Detector should inbuilt Isolators as per NFPA 72 style 7 wiring requirements for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electro magnetic Detector should monitor Electromagnetic interference and report to the panel current and average values. Detector should have IP30 or better protection rating. Shall be UL/EN/VDS certification. (Detectors should have Inbuilt Isolators). (Make: Eaton, Morley, Bosch,Siemens)

1

-

-

... More
Supply, installation, testing and commissioning of intelligent Analog Addressable type Manual Call Point with RED LED should blink in normal conditions and LED should be continues in fire conditions. having Surface or flush mounting option fully compliant to EN 54 having auto addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete thejob in all respect up to the entire satisfaction of Engineer in Charge of work. Make : (Make: Eaton, Bosch, Siemens)

2

-

-

... More
Supply, installation, testing and commissioning of Addressable Control Relay Module should have soft addressing features, isolator should be inbuilt with flexible network structures with a maximum switching current of 1A @30V DC.I should have inbuilt isolator. Shall be EN54/UL/VDS Certification Make: (Make: Eaton, Bosch,Siemens)

1

-

-

... More
SITC of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/voltage monitoring, it should have soft addressing features, isolator should be inbuilt shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Make: (Make: Eaton, Bosch,Siemens)

1

-

-

... More
Supply erection testing and commissioning 2Core 1.5 sq. mm, FRLS Armoured, two core copper conductor cable including required accessories for erection Polycab /Havells/RR Kabel

395

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.