Public Works Department Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Public Works Department - PWD Tender

Works
Security and Emergency Services
Eprocure
Opening Date29 Nov 2023
Closing Date12 Dec 2023
Tender Amount₹ 17,13,290 
Notes
Download

Costs

  • EMD

    ₹ 34,266
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 2KVA Online UPS with 2hr power Backup with all necessary accessories civil electrical works and peripheral items.. (Makes:- APC/LUMINIOUS/ELNOVA.

1

-

-

... More
Wiring for Fire Alarm system with the following sizes of FRLS insulated copper conductor single core 1100 volts grade cables in existing surface/recessed M.S. conduit etc. as complete as required. Make Finolex/Havel/Polycab 2 x 1.5 sq.mm

3400

-

-

... More
SITC of PVC conduit pipe 25mm dia ISI marked (medium) recessed in wall/ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer -incharge of the work. Make: BEC, AKG,Kalinga / Diplast/Finolex. 25 mm

900

-

-

... More
SITC of Analog Addressable type Active Repeater Fire Alarm Panel with Backlit LCD display, having controlls for reset, mute, accept, silence alarms and self test conforming to BS5839 standards with all labour and materials required to complete the job in all respect up to the entire satisfaction for engineer-in-charge of work. Make Siemens/Bosch/Morley ZXRA/G.S.T

1

-

-

... More
SITC of addressable Photoelectric detector including base, auto addressing features as required. Detectors should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005. EMC safety for detector shall be 50 V/m. shall be EN54/VDS/UL certification. (Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Makes: Honeywell/ Morley/ Siemens/Bosch/G.S.T.

220

-

-

... More
SITC of addressable Heat Detector with fixed and rate of raise feature including mounting base with LED etc complete as required. Each detector should have 2 as per NFPA 72 style 7 wiring requirement (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005. Detector should monitor electromagnetic interference and report to the panel current and average values, EMC safety for detector shall be 50 V/m. shall be EN54/VDS/U: certification. (Detectors without inbuilt isolators may be considered with an additional isolator module per detector. Makes: Bosch/Honeywell/Siemens/Morley/G.S.T.

10

-

-

... More
Supply, installation, testing and commissioning of intelligent Analog Addressable type Isolator having Surface or flush mounting option fully compliant to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect Makes :Bosch/Morley/Honeywell/Siemens/G.S.T

4

-

-

... More
Supply, installation, testing and commissioning of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Makes:- Honeywell/Bosch/Siemens/G.S.T/Morley

1

-

-

... More
Supply, installation, testing and commissioning of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment).Make Bosch/Honeywell/Morley/Siemens/G.S.T.

1

-

-

... More
Supply, installation, testing and commissioning of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliant to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect Makes: Bosch/Honeywell/Morley/G.S.T/Siemens

10

-

-

... More
Supply, installation, testing and commissioning of Addressable Loop powered sounder with strobe/flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect Makes:- Honeywell/Bosch/Morley/G.S.T/Siemens

10

-

-

... More
SITC of Intelligent Analog Addressable type Response Indicator with all labor and material required to complete the job in all respect Makes:- Bosch/Honeywell/Siemens/G.S.T/Morley

30

-

-

... More
Supply Installation, Testing and Commissioning of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener Managed Type including cost of labour and material required to complete the job in all respect. Make:- PES/Glolite/OMEX

10

-

-

... More
Supply of addressable Loop powered hooter with strobe complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required complete the of in all respect . Makes:- Honeywell/Morley/Siemens/Bosch/G.S.T

2

-

-

... More
SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (Expandable to 2 loops to suit minimum 20% extra over the nos. of fire detectors). The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must have 4 access levels and Panel should be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 7` or bigger Touch Screen to Program and indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 2000 Zones with individual LED Indicators, expandable to Virtual 40 LED Indicators. The Panel shall have 2 Serial Ports. The panel shall have a built in power supply, battery charger maintenance free battery capable of running for a minimum 24 hours operation complete as required and 10000 Event Log History . And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work. Make Siemens/Bosch/Honeywell Morley Zxe series /G.S.T

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.