Public Works Department Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 43,180Document Cost
₹ 1,000Tender Fee
₹ 1,180
Summary
Replacement Of Existing Fire Alarm System With New One In Judicial Court Complex Jhajjar In District Jhajjar
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_HRY_332525_1Bid Award Id
ViewTender No
202381600F05 79A8 42C6 9420 F7466D3FBBAE667BARTender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://haryanapwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
SITC of addressable multisensor detector with a combination of Optical and Thermal including mounting base, auto addressing feature as required. Detector should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005. Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices) Make: Bosch / Siemens Cerberus / GST/ Honeywell Morley
265
-
-
SITC of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully complaint to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Bosch / Siemens Cerberus / GST/ Honeywell Morley
20
-
-
SITC of Addressable Loop powered sounder with strobe / flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Bosch / Siemens Cerberus / GST/ Honeywell Morley
20
-
-
SITC of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/ voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Make: Bosch / Siemens Cerberus / GST/ Honeywell Morley
2
-
-
SITC of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Make:Bosch / Siemens Cerberus / GST/ Honeywell Morley
2
-
-
SITC of UL/EN54/LPCB listed and FM Approved Line Isolator for Isolating the section of circuit in case of short in the addressable Loop wiring Make: Bosch / Siemens Cerberus / GST/ Honeywell Morley
15
-
-
SITC of minimum 1000 Mtr. Range Siren provided at the roof of the building with separate power supply, relay etc. with all accessories required to complete the job in all respect up to the entire satisfaction of engineer in charge. Make: National / Kheraj
1
-
-
SITC of Microprocessor based 2 wire fault tolerant, networkable type fire alarm / detection control panel (having nos. of 2 loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module whenever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160-character L C D unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80LED Indicators. The Panel shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt
SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work
Makes: Bosch FPA 1000/ Honeywell Morley DXE/ GST 200 (EN)/Siemens Cerberus
1
-
-
Supply Installation Testing and Commissioning of Public Address System in Rack: consisting of the following: - i) 120W Amplifier to suitable size Make: Bosch / Siemens Cerberus / GST/ Honeywell Morley - 01 No. ii) Selector and all facility for announcement of different floor - 01 Set iii) Interface unit for integration of main fire alarm panel with public address system = 01 No.
1
-
-
Supply, Installation, Testing and commissioning of Celling Mount/ wall mount Speaker with Plastic Mount or without mount as per site requirement for operation 6 Watts Make: Honeywell / BOSCH / Henrich
20
-
-
Supply Installation Testing and Commissioning of addressable Heat detector with fixed and rate of raise feature including mounting base with LED etc. complete as required. Each Detector should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005. Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make: Bosch / Siemens Cerberus / GST/ Honeywell Morley
10
-
-
Supply Installation Testing and Commissioning of Analog Addressable type Active Repeater fire alarm panel with Backlit LCD Display, having controls for reset, mute, Accept, Silence alarms and self-test conforming to BS5839 standards and Duly approved by EN54/UN54/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Bosch / Siemens Cerberus / GST/ Honeywell Morley
3
-
-
Supply Installation Testing and Commissioning of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make : Glolite / PES / Omex
20
-
-
Supply and erection of PVC Insulated and FRLS Round Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Flexible Cables for Voltage Grade 1100 Volts conforming to IS: 694:2010 complete in all respect upto the entire satisfaction of Engineer in charge of the work. i) 2 core PVC unsheathed copper size 1.5 sq mm
Make Polycab / Havells / Finolex
500
-
-
Supplying and laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000 V rated with annealed copper conductor having XLPE Insulation, Steel Wire armouring, FRLS Outer seathing complete as required complete in all respect entire satisfaction of Engineer in charge of the work. Make Polycab / Havells / Finolex
3200
-
-
`Supply, installation, testing and commissioning` of 17 U Standard rack to place all Av equipment Make Valrack / Comrack / Hive Networks HN).
1
-
-
Supply Installation Testing and Commissioning of battery backup for controllers (2 KVA UPS off line with 1 hour’s backup) and all other material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work. Make APC / Liebert / Emerson / Microtek
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements