Public Health Engineering Department Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 32,61,770Document Cost
₹ 20,000Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HRY_376219_1Bid Award Id
ViewTender No
2024628208A9 E219 4F07 A346 6BC6453897DB560PUHTender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://https://phedharyana.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Repair of Old Existing Water Supply Connections Damaged During Laying of Water Supply Pipe Line Against Old Existing Pipe Line..
4310
-
-
Providing, Laying, Jointing testing and commissioning of MS Pipe and specials of required size (150mm,200mm,250mm as per site requirement) for suction pipe from UGT and delivery pipe including all
specials, welding of flanges plates Nut bolts ,Rubber Gasket, fixing of NRV And Sluice Valve with extension Joint etc. upto Raising main complete Job in all respects in entire satisfaction of Engineer in charge
4
-
-
Supplying, erection, testing and commissioning of submersible pumping set as per BIS SPECIFICATION No. 8034-1989 (as amended upto date for pump) and IS 9283-
1979 (as amended upto date for motor ) the pump motor sets should be capable of pumping clear fresh cold water having characterstics as specified in Clause-4 of IS 8034-1989 and Clause 4.1 of IS 9283-1979
i) 200 LPM/ 160Mtrs .Head (15.00 BHP)
12
-
-
PROVIDING AND FIXING 15MM CLASS B REPUTED MAKE WATER METER AND FIXING FOR FHTC COMPLETE WITH ALL RESPECT AS PER SATISFACTION OF ENGINEER-IN-CHARGE. REPUTED MAKE I.E KRANTI
5819
-
-
Gas Chlorination: Providing, fixing,testing and commissioning of Vacuum Gas Chlorination system of rating 2000 grams per hour having the control of gas 20th part of max. dose and which can start working automatically on switching in the supply of water at the site of boosting station consisting of following parts:-
a) vacuum regulator
b) flow meter with control valve assembly
c) Differential pressure regulator
d) Pressure relief valve
e) Vacuum relief valve
f) Online Chlorine Analyzer for chlorine and turbidity of water
g) Auto Shut off Valve
h) Automatic Switchover System (1 Working plus 1 Standby)
i) 2 nos. filled of chlorine cylinders of capacity 100 kg duly certified and approved by BIS and explosive department Govt. of India
j) Chlorine Gas Detection System(chlorine leak detector with hooter and sensor)
k) Chlorine Gas Scrubber
including spanner with cylinder opening key, 2 set connectors, iron cage guard, safety equipments consisting of chlorine mask with canister and complete installation of the equipments and all other works contingent thereto as per detailed specification as per Annexure A and as per satisfaction of Engineer-In-Charge including operation and maintenance of entire system during defect liability period of 1 year after successful trial run period of 3 months and thereafter operation and maintenance for 5 years...
2
-
-
Supply, erection and testing of Variable frequency drive for 150 HP Horizontal Pump Motor Set Compatible to work with cable length of 300 meters and to ensure that there is no voltage drop , Variable frequency drive IP66 with mains Disconnect having Modbus Communication and designed at 50 Degree Celsius without any deration
with inbuilt real time clock for time assistance. Variable frequency drive All Electronic cards should be 3C3
Coated. Variable frequency drive with Dual DC choke at both the Limbs with 5 % Impedance. Variable frequency
should be having all protection features like Dry Run detection, Deragging, Automatic energy
optimization, Low flow detection, sleep mode, complete in all respect including earthing and its connection,
erection and commissioning complete in all respect to the entire satisfaction of engineer in charge.
2
-
-
Supply, erection and testing of Variable frequency drive for 60 HP Horizontal Pump Motor Set Compatible to work with cable length of 300 meters and to ensure that there is no voltage drop , Variable frequency drive IP66 with mains Disconnect having Modbus Communication and designed at 50 Degree Celsius without any deration
with inbuilt real time clock for time assistance. Variable frequency drive All Electronic cards should be 3C3
Coated. Variable frequency drive with Dual DC choke at both the Limbs with 5 % Impedance. Variable frequency
should be having all protection features like Dry Run detection, Deragging, Automatic energy
optimization, Low flow detection, sleep mode, complete in all respect including earthing and its connection,
erection and commissioning complete in all respect to the entire satisfaction of engineer in charge.
2
-
-
Supply, erection and testing of Variable frequency drive for 30HP Horizontal Pump Motor Set Compatible to work with cable length of 300 meters and to ensure that there is no voltage drop , Variable frequency drive IP66 with mains Disconnect having Modbus Communication and designed at 50 Degree Celsius without any deration
with inbuilt real time clock for time assistance. Variable frequency drive All Electronic cards should be 3C3
Coated. Variable frequency drive with Dual DC choke at both the Limbs with 5 % Impedance. Variable frequency
should be having all protection features like Dry Run detection, Deragging, Automatic energy
optimization, Low flow detection, sleep mode, complete in all respect including earthing and its connection,
erection and commissioning complete in all respect to the entire satisfaction of engineer in charge.
4
-
-
Supply, erection and testing of Variable frequency drive for 40 HPHorizontal Pump Motor Set Compatible to work with cable length of 300 meters and to ensure that there is no voltage drop , Variable frequency drive IP66 with mains Disconnect having Modbus Communication and designed at 50 Degree Celsius without any deration
with inbuilt real time clock for time assistance. Variable frequency drive All Electronic cards should be 3C3
Coated. Variable frequency drive with Dual DC choke at both the Limbs with 5 % Impedance. Variable frequency
should be having all protection features like Dry Run detection, Deragging, Automatic energy
optimization, Low flow detection, sleep mode, complete in all respect including earthing and its connection,
erection and commissioning complete in all respect to the entire satisfaction of engineer in charge.
2
-
-
Providing and Inserting of 600 mm i/d M.S. pipe 12 mm thick(Fe-330 grade)Fabricated as per IS 3589 of 1991 from steel plates confirming to IS:-2062 including cutting, beveling, grinding and jointing with radiographically welding of pipe as per IS- 1182 and testing complete in all respect.
100
-
-
Supplying, erection, testing and commissioning or Horizontal Centrifugal motor
pumping set or Clear Water having head 40.00 m as requirements of
discharge in LPM and power capacity in BHP Make: KSEB, CRI, Kirlosker,
Crompton Greeve, Lubi) 7800 LPM , 120 BHP
2
-
-
(Supplying, erection, testing and commissioning or Horizontal Centrifugal motor pumping set or Clear Water having head 35.00 m as requirements of discharge in LPM and power capacity in BHP Make: KSEB, CRI, Kirlosker, Crompton Greeve, Lubi) 2500 LPM , 35.00 BHP
2
-
-
(((Supplying, erection, testing and commissioning or Horizontal Centrifugal motor pumping set or Clear Water having head 35.00 m as requirements of discharge in LPM and power capacity in BHP Make: KSEB, CRI, Kirlosker, Crompton Greeve, Lubi) 3200 LPM , 45.00 BHP
2
-
-
Boring / excavation including pit making at entry and exist point
to the prices dimension for the launch of the specialized
Auger boring machine in normal soil condition but not in
Rock / Bolders / any underground utility like foundation,
Water Supply line coming in alihnment or other underground
obstructions including caution sing boards , signals, watching
fencing, site clearance etc.
120
-
-
(Boring / excavation including pit making at entry and exist point
to the prices dimension for the launch of the specialized
Auger boring machine in normal soil condition but not in
Rock / Bolders / any underground utility like foundation,
Water Supply line coming in alihnment or other underground
obstructions including caution sing boards , signals, watching
fencing, site clearance etc.
90
-
-
((Boring / excavation including pit making at entry and exist point
to the prices dimension for the launch of the specialized
Auger boring machine in normal soil condition but not in
Rock / Bolders / any underground utility like foundation,
Water Supply line coming in alihnment or other underground
obstructions including caution sing boards , signals, watching
fencing, site clearance etc.
50
-
-
)Boring / excavation including pit making at entry and exist point
to the prices dimension for the launch of the specialized
Auger boring machine in normal soil condition but not in
Rock / Bolders / any underground utility like foundation,
Water Supply line coming in alihnment or other underground
obstructions including caution sing boards , signals, watching
fencing, site clearance etc.
30
-
-
Providing for probe radar survey to check any underground
obstruction before finalizing the alignment.
4
-
-
Providing, laying and Jointing of 355 mm od M.S. Casing pipe 8.00 mm thick (Fe-330 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following sizes including cutting, beveling, grinding and radio graphically welding of pipes as per IS-1182 complete in all respect and also coating of inner and outer surface of casing pipe with high built epoxy paint to R.D.S.O. as per specification No. MandC/PCN.III/88 to a dry film thickness of 250 micron for protection against corrosion complete in all respect under Railway track including cartage of material to site of work and testing complete in all respect as per satisfaction of Engineer-in-Charge
50
-
-
Providing and Insertion of W/S pipeline 219.1 mm od M.S. pipe (Fe-330 grade) fabricated as per IS:3589 of 1991, from steel plates conforming to IS:2062, 6.3 mm thick by providing Roller arrangement for smooth insertion and anchoring of pipe through out the length with HDPE spacers at a distance of 2 meters apart to avoid contract of carrier pipe including cutting, jointing, radio graphically welding as per IS:1182 Hydraulic testing complete in all respect and also with cement mortar lining 8.00mm thick on inner surface including cartage of material to site of work complete in all respect as per satisfaction of Engineer-in-Charge.
51
-
-
Providing and Fixing HDPE Specer to be fitted in MS casing pipe of size 355.6 mm od and Carrier pipe of size 219.1 mm od complete job including labour charges, cartage of material to site of work complete in all respect as per satisfaction of Engineer-in-Charge.
26
-
-
Providing, laying and Jointing of 273.00 mm od M.S. Casing pipe 6.3 mm thick (Fe-330 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following sizes including cutting, beveling, grinding and radio graphically welding of pipes as per IS-1182 complete in all respect and also coating of inner and outer surface of casing pipe with high built epoxy paint to R.D.S.O. as per specification No. MandC/PCN.III/88 to a dry film thickness of 250 micron for protection against corrosion complete in all respect complete in all respect as per satisfaction of Engineer-in-Charge
120
-
-
Providing and Insertion of W/S pipeline 168.3 mm od M.S. pipe (Fe-330 grade) fabricated as per IS:3589 of 1991, from steel plates conforming to IS:2062, 4.5 mm thick by providing Roller arrangement for smooth insertion and anchoring of pipe through out the length with HDPE spacers at a distance of 2 meters apart to avoid contract of carrier pipe including cutting, jointing, radio graphically welding as per IS:1182 Hydraulic testing complete in all respect and also with cement mortar lining 8.00mm thick on inner surface including cartage of material to site of work complete in all respect as per satisfaction of Engineer-in-Charge.
121
-
-
Providing and Fixing HDPE Specer to be fitted in MS casing pipe of size 273.00 mm od and Carrier pipe of size 168.3 mm od complete job including labour charges, cartage of material to site of work complete in all respect as per satisfaction of Engineer-in-Charge.
61
-
-
Providing, laying and Jointing of 323.9 mm od M.S. Casing pipe 7.1 mm thick (Fe-330 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following sizes including cutting, beveling, grinding and radio graphically welding of pipes as per IS-1182 complete in all respect and also coating of inner and outer surface of casing pipe with high built epoxy paint to R.D.S.O. as per specification No. MandC/PCN.III/88 to a dry film thickness of 250 micron for protection against corrosion complete in all respect complete in all respect as per satisfaction of Engineer-in-Charge
90
-
-
Providing and Insertion of W/S pipeline 168.3 mm od M.S. pipe (Fe-330 grade) fabricated as per IS:3589 of 1991, from steel plates conforming to IS:2062, 4.5 mm thick by providing Roller arrangement for smooth insertion and anchoring of pipe through out the length with HDPE spacers at a distance of 2 meters apart to avoid contract of carrier pipe including cutting, jointing, radio graphically welding as per IS:1182 Hydraulic testing complete in all respect and also with cement mortar lining 8.00mm thick on inner surface including cartage of material to site of work complete in all respect as per satisfaction of Engineer-in-Charge.
91
-
-
Providing and Fixing HDPE Specer to be fitted in MS casing pipe of size 323.9 mm od and Carrier pipe of size 163.3 mm od complete job including labour charges, cartage of material to site of work complete in all respect as per satisfaction of Engineer-in-Charge.
46
-
-
Providing, laying and Jointing of 406.4 mm od M.S. Casing pipe 8.88 mm thick (Fe-330 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following sizes including cutting, beveling, grinding and radio graphically welding of pipes as per IS-1182 complete in all respect and also coating of inner and outer surface of casing pipe with high built epoxy paint to R.D.S.O. as per specification No. MandC/PCN.III/88 to a dry film thickness of 250 micron for protection against corrosion complete in all respect under Railway track including cartage of material to site of work and testing complete in all respect as per satisfaction of Engineer-in-Charge
30
-
-
Providing and Insertion of W/S pipeline 273.00 mm od M.S. pipe (Fe-330 grade) fabricated as per IS:3589 of 1991, from steel plates conforming to IS:2062, 6.3 mm thick by providing Roller arrangement for smooth insertion and anchoring of pipe through out the length with HDPE spacers at a distance of 2 meters apart to avoid contract of carrier pipe including cutting, jointing, radio graphically welding as per IS:1182 Hydraulic testing complete in all respect and also with cement mortar lining 8.00mm thick on inner surface including cartage of material to site of work complete in all respect as per satisfaction of Engineer-in-Charge.
31
-
-
Providing and Fixing HDPE Specer to be fitted in MS casing pipe of size 406.4 mm od and Carrier pipe of size 273.00 mm od complete job including labour charges, cartage of material to site of work complete in all respect as per satisfaction of Engineer-in-Charge.
16
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements