Public Health Engineering Department Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Pipe Line Project
Water Storage And Supply
Eprocure
Opening Date18 Jul 2024
Closing Date1 Aug 2024
Tender Amount₹ 8,31,51,265 
Notes
Download

Costs

  • EMD

    ₹ 16,63,025
  • Document Cost

    ₹ 20,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing 1 No. Household Tap Connection (FHTC) with restoration of Cement concrete streets

3180

-

-

... More
Repair of Old Existing Sewerage Connections Damaged During Laying Of Water Pipe Line.

300

-

-

... More
Repair of Old Existing Water Supply Connections Damaged During Laying of Water Supply Pipe Line Against Old Existing Pipe Line.

300

-

-

... More
Installation of Barod Band Wifi Connection

12

-

-

... More
Net Metering system on the existing feeder by changing Meter CT /PT etc

1

-

-

... More
Variable frequency drive for 20 HP Submersible Motor Compatible to work with cable length of 300 meters and to ensure that there is no voltage drop , Variable frequency drive IP66 with mains Disconnect having Modbus Communication and designed at 50 Degree Celsius without any deration with inbuilt real time clock for time assistance. Variable frequency drive All Electronic cards should be 3C3 Coated. Variable frequency drive with Dual DC choke at both the Limbs with 5 % Impedance. Variable frequency should be having all protection features like Dry Run detection, Deragging, Automatic energy optimization, Low flow detection, sleep mode, complete in all respect including earthing and its connection, erection and commissioning complete in all respect to the entire satisfaction of engineer in charge.

2

-

-

... More
PROVIDING AND FIXING 15MM CLASS B REPUTED MAKE WATER METER AND FIXING FOR FHTC COMPLETE WITH ALL RESPECT AS PER SATISFACTION OF ENGINEER-IN-CHARGE. REPUTED MAKE I.E KRANTI

3180

-

-

... More
Supply, erection and testing of Variable frequency drive for 50 HP Horizontal Pump Motor Set Compatible to work with cable length of 300 meters and to ensure that there is no voltage drop , Variable frequency drive IP66 with mains Disconnect having Modbus Communication and designed at 50 Degree Celsius without any deration with inbuilt real time clock for time assistance. Variable frequency drive All Electronic cards should be 3C3 Coated. Variable frequency drive with Dual DC choke at both the Limbs with 5 % Impedance. Variable frequency should be having all protection features like Dry Run detection, Deragging, Automatic energy optimization, Low flow detection, sleep mode, complete in all respect including earthing and its connection, erection and commissioning complete in all respect to the entire satisfaction of engineer in charge.

6

-

-

... More
Supply, erection and testing of Variable frequency drive for 30HP Horizontal Pump Motor Set Compatible to work with cable length of 300 meters and to ensure that there is no voltage drop , Variable frequency drive IP66 with mains Disconnect having Modbus Communication and designed at 50 Degree Celsius without any deration with inbuilt real time clock for time assistance. Variable frequency drive All Electronic cards should be 3C3 Coated. Variable frequency drive with Dual DC choke at both the Limbs with 5 % Impedance. Variable frequency should be having all protection features like Dry Run detection, Deragging, Automatic energy optimization, Low flow detection, sleep mode, complete in all respect including earthing and its connection, erection and commissioning complete in all respect to the entire satisfaction of engineer in charge.

6

-

-

... More
Gas Chlorination: Providing, fixing,testing and commissioning of Vacuum Gas Chlorination system of rating 2000 grams per hour having the control of gas 20th part of max. dose and which can start working automatically on switching in the supply of water at the site of boosting station consisting of following parts:- a) vacuum regulator b) flow meter with control valve assembly c) Differential pressure regulator d) Pressure relief valve e) Vacuum relief valve f) Online Chlorine Analyzer for chlorine and turbidity of water g) Auto Shut off Valve h) Automatic Switchover System (1 Working plus 1 Standby) i) 2 nos. filled of chlorine cylinders of capacity 100 kg duly certified and approved by BIS and explosive department Govt. of India j) Chlorine Gas Detection System(chlorine leak detector with hooter and sensor) k) Chlorine Gas Scrubber including spanner with cylinder opening key, 2 set connectors, iron cage guard, safety equipments consisting of chlorine mask with canister and complete installation of the equipments and all other works contingent thereto as per detailed specification as per Annexure A and as per satisfaction of Engineer-In-Charge including operation and maintenance of entire system during defect liability period of 1 year after successful trial run period of 3 months and thereafter operation and maintenance for 5 years....

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.