Public Health Engineering Department Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 7,33,920Document Cost
₹ 15,000Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HRY_418331_1Tender No
2024C223220B 3231 4B09 87E7 F2FD609F3E62588PUHTender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://https://phedharyana.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supplying, Errection, testing and commissioning Horizontal motor pumping set of Raw water having head
12.00 m as requirements of discharge 700 LPM and power capacity 5.00 BHP as ISI Marked
2
-
-
... More
Water Treatment Plant (WTP) - Designing, Testing, Construction and Commissioning of 1.00 MLD capacity water treatment plant including inlet channel alum dozing, flash mixing, clari floculator, filtter box, over head reservoir for back wash, waste water tank, including all civil work pumping machinery and electric cabling, control panel, entire piping network of suitable size, supplying, laying, cutting and jointing of DI pipes from raw water pump to inlet box of WTP, WTP to CWT and Suction well for CW including, DI specials suitable size sluice valves, hodies, manhole covers, air scour equipment, chemical house including chlorination equipment and arrangement of flow measurement and sand bed with automation complete in all respects as per approved NIT. (Sluice valve of make IVCAWAG)
1
-
-
... More
`NS Item - PANEL BOARDS FOR MOTOR:- Supply Erection,Testing and Commissioning of wall mounted electrical LT Panel board , fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)
START DELTA STARTER :- 1.Main MCCB(ABB/LandT/SCHNEIDER - 01nos
2. Controlling MCB - 01nos
3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos
4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos
5.START/STOP PUSH BUTTON(SCHNEIDER/SALZAR/SEIMENS)
6.EMERGENCY SWITCH(SCHNEIDER/SALZAR/SEIMENS) - 01 nos
7.DIGITAL VAF METER(SECURE/SELEC/TECHNO/ABB) - 01 nos
8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos
9. CAPACITOR BANK AS PER LOAD REQUIREMENT
10. CHANGE OVER SWITCH AS PER LOAD(SCHNEIDER/SALZAR/SEIMENS) - 01 nos
11.SELECTOR SWITCH(SECURE/SELEC/TECHNO/ABB) - 01 nos
12. SINGLE PHASE PREVENTER(SECURE/SELEC/TECHNO/ABB) -01 nos
13.ELCB BREAKER(ABB/LandT/SCHNEIDER) 800 LPM x 40 Mtr head (for filling the boosting station)
2
-
-
... More
PANEL BOARDS FOR MOTOR:- Supply Erection,Testing and Commissioning of wall mounted electrical LT Panel board , fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping) START DELTA STARTER :- 1.Main MCCB(ABB/LandT/SCHNEIDER - 01nos 2. Controlling MCB - 01nos 3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos 4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos 5.START/STOP PUSH BUTTON(SCHNEIDER/SALZAR/SEIMENS) 6.EMERGENCY SWITCH(SCHNEIDER/SALZAR/SEIMENS) - 01 nos 7.DIGITAL VAF METER(SECURE/SELEC/TECHNO/ABB) - 01 nos 8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos 9. CAPACITOR BANK AS PER LOAD REQUIREMENT 10. CHANGE OVER SWITCH AS PER LOAD(SCHNEIDER/SALZAR/SEIMENS) - 01 nos 11.SELECTOR SWITCH(SECURE/SELEC/TECHNO/ABB) - 01 nos 12. SINGLE PHASE PREVENTER(SECURE/SELEC/TECHNO/ABB) -01 nos 13.ELCB BREAKER(ABB/LandT/SCHNEIDER) 800 LPM x 35 Mtr head (for boosting station)
2
-
-
... More
`NS Item - PANEL BOARDS FOR MOTOR:- Supply Erection,Testing and Commissioning of wall mounted electrical LT Panel board , fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)
START DELTA STARTER :- 1.Main MCCB(ABB/LandT/SCHNEIDER - 01nos
2. Controlling MCB - 01nos
3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos
4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos
5.START/STOP PUSH BUTTON(SCHNEIDER/SALZAR/SEIMENS)
6.EMERGENCY SWITCH(SCHNEIDER/SALZAR/SEIMENS) - 01 nos
7.DIGITAL VAF METER(SECURE/SELEC/TECHNO/ABB) - 01 nos
8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos
9. CAPACITOR BANK AS PER LOAD REQUIREMENT
10. CHANGE OVER SWITCH AS PER LOAD(SCHNEIDER/SALZAR/SEIMENS) - 01 nos
11.SELECTOR SWITCH(SECURE/SELEC/TECHNO/ABB) - 01 nos
12. SINGLE PHASE PREVENTER(SECURE/SELEC/TECHNO/ABB) -01 nos
13.ELCB BREAKER(ABB/LandT/SCHNEIDER)
1900 LPM x 45 Mtr. Head (for clear water)
2
-
-
... More
Operation and Maintenance for complete scope of work mentioned in the DNIT (Disinfection material supplied by PHED) as per schedule-IV for a period of 5 year after 12 month during defect liability period and 03 Months trial run period will be charged to the
A/Mtc. estimate complete in all respect as per approved NIT
(i) Operation and Maintenance during defect liability period (Operation only) after 3 month trial run period.
1
-
-
... More
(ii) Operation and Maintenance during 1st year after defect liability period.
1
-
-
... More
(iii) Operation and Maintenance during 2nd year.
1
-
-
... More
(iv) Operation and Maintenance during 3rd year.
1
-
-
... More
(v) Operation and Maintenance during 4th year.
1
-
-
... More
(vi) Operation and Maintenance during 5th year.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%