Haryana Police Housing Corporation Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 16,000Document Cost
₹ 1,000Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HBC_414716_1Bid Award Id
ViewTender No
202465BF6954 3D7F 430C A494 262FCA8FDC0C57HHCTender Authority
Haryana Police Housing Corporation ViewPurchaser Address
-Website
http://https://hphc.org.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
[23.24.4.1]MS STAND, BUS BAR CHAMBER AND PANELS 4.1. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 4 way 250 amp. [Through Rate]
1
43169
43169
... More
[23.3.6.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
50
88
4400
... More
[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
40
730
29200
... More
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate]
2
3368
6736
... More
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate]
2
8275
16550
... More
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate]
4
801
3204
... More
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
50
96
4800
... More
[24.13.76]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 76. 150 Sq mm 3.5 core (Arm.) [Through Rate]
25
799
19975
... More
[24.2.7.5]LT CABLE 7.5. Supply and erection of suitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 Core [Through Rate]
6
133
798
... More
[24.2.8.11]LT CABLE 8.11. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 150 sqmm [Through Rate]
9
40
360
... More
[24.2.8.8]LT CABLE 8.8. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 70 sqmm [Through Rate]
3
20
60
... More
[24.7.4]RCC FOUNDATIONS FOR DG SET 4. 125 KVA DG Set [Through Rate]
1
27801
27801
... More
Supply , Installation, testing and commissioning of 125 KVA water cooled , silent diesel Generating set as per CPCB- IV norms with latest amendments complete with alternator rated at three phase 415 volts, 50 cycle, 0.8 PF and 1500 RPM with AMF Panel (outside/inside the canopy), Acoustic Enclosure and battery charger etc.( To be installed out door on existing platform excluding cost of platform ) as per following specifications : A. DIESEL ENGINE :- Multi cylinder Engine developing output as per 125 KVA at 1500 RPM, Vertical, totally enclosed, water cooled, comprising compression ignition, electric start, minimum 4 stroke high speed diesel engine conforming to IS - 4722 , ISO - 3046, BS - 5514 and Engine should be as per CPCB IV norms. The engine shall be coupled with 3 phase 415 volts, 50 cycle, 0.8 PF and 1500 RPM, alternator as per IS - 4722 / BIS - 2613, rated for 24 hours of continuous operation with 10 % over load capacity for one hour in every 12 hours. The engine shall be complete with all standard and electrical accessories as per standard supply of manufactures comprising with ON / OFF start keys, Lube oil pressure gauge , Fuel Tank with capacity for 8 hours continuous running at full load. B) AMF Panel:- AMF Panel made with 1.60 mm thick CRCA Sheet with IP-53 protection as per IS /IEC :60947 (Part-I) / 2007 and should be complete with all standard accessories as required and as per followings :- (i) AC Digital volts and Amperes meter with selector switch of class 1.5 accuracy (ii) 3nos Pilot Lamps (RYB) and 5 nos. Indicating lamps to indicate Main low voltage , Load on Mains , DG set running , Load on DG set and battery charger ON (iii) 3nos, 4 pole MCCB of suitable capacity i.e 1no. on Mains supply input side ,1no. on output of DG set supply and 1no. on output supply of AMF panel (iv) 2nos, 4 pole Contractors of suitable capacity in AMF Panel for mains and DG Set (v) Under voltage relay for Mains (vi) Over voltage protection and any other accessories to make the generating set functional shall be installed as per manufacturer`s design. C) BATTERY and BATTERY CHARGER:- 1 No 12 Volts DC Maintenance Free battery with leads and container of suitable AH capacity.The battery charger with volt metre and Ammeter shall be installed of required size and rating for charging of battery from mains. This will be in addition to the battery charging alternator fitted on the engine. D) ACCOUSTIC ENCLOSURE : Acoustic enclosure shall be provided as per Technical specification as follows :-
1) CONSTRUCTION and PAINTING : i) The enclosure shall be fabricated out of 16 SWG CRCA sheet with Weather proof anti corrosion treatment to be provided to the entire structure with powder coating and Silent D.G. set container shall be of modular construction with the provision to assemble and dismantle easily at site of work.
ii) The base fame shall be made of suitable section/Channel.
iii) Residential Silencer of required size and length i/c all necessary material as reqd. iv) Durable industrial system is to be provided on the doors and doors are fitted with high quality EPDM gasket to avoid leakage of sound. v) Neutral/Body earthing points at the side of enclosure are to be provided.
vi) Emergency stop push button shall be provided outside the container.
vii) A LED fitting for proper light inside the canopy shall be provided. 2). ACCOUSTIC INSULATION :-
i) Sound proofing of the enclosure shall be done with quality rock wood/Mineral wood conforming to IS-8183-1993 of 25mm thickness and density at 30 Kg./M compressed along with 3mm thick vinyl sheet and non ferrous sheet or PU Foam. ii) Exhaust pipe is to be thoroughly insulated by covering it with glass wool and further claded with Aluminium sheet.
iii) A noise level as per CPCB- IV norms with latest amendments. Note:- Any other material required to complete the Acoustic Enclosure shall be installed as per manufacturer`s specifications.
1
1398450
1398450
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements