Haryana Police Housing Corporation Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Haryana Police Housing Corporation - HPHC Tender

Works
Coronavirus COVID 19
Eprocure
Opening Date10 Sep 2019
Closing Date24 Sep 2019
Tender Amount₹ 1,94,42,070 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Clearing grass and removal of the rubbish upto distance of outside the periphery of the area cleared. as per HSR 6.27 (C.P.@370%)

588.87

-

21.45

... More
Centring and shuttering for sides and soffits of beams haunchings, girders, bressumers and lintels. (HSR 9.7 + CP @ 400%) 1st Storey

288.18

-

57.8

... More
2nd Storey

273.3

-

61.8

... More
3rd Storey

47.62

-

65.8

... More
4th storey

2.27

-

69.8

... More
Shuttering for faces of concrete foundations and foundations beams (vertical or battering) (HSR 9.13) (CP @ 400%)

281.73

-

30.65

... More
Cement concrete 1 : 8 : 16 with brick ballast 40 mm Nominal size in foundation and plinth (HSR 10.26 CP 450%)

14.61

-

300.2

... More
Cement concrete 1 : 8 : 16 with stone aggregate 40 mm Nominal size in foundation and plinth. as per HSR 10.28. (CP @450%)

50.15

-

318.65

... More
Cement concrete 1 : 4 : 8 with stone aggregate 40 mm Nominal size in foundation and plinth. as per HSR 10.39. (CP @450%)

39.87

-

403.1

... More
Cement concrete 1:1 ½:3 with stone aggregate 20 mm nominal size in first storey upto 4 metres above plinth level, as per HSR 10.60 (C.P.@450%) 1st storey

0.68

-

708.75

... More
2nd storey

0.68

-

711.3

... More
Cement concrete 1:1.5:3 with stone aggregate 20 mm nominal size for reinforced concrete work but excluding steel-reinforcement centring and shuttering in foundation and plinth., as per HSR 10.79 + 10.95 (CP @ 450%)

87.89

-

712.7

... More
Cement concrete 1:1.5:3 with stone aggregate 20 mm nominal size for reinforced concrete work, but excluding steel reinforcement, centring and shuttering in first storey upto 4 metres above plinth level. (HSR 10.80 + 10.95a) CP 450% 1st Storey

16.46

-

718.95

... More
2nd storey

15.61

-

726.25

... More
3rd storey

2.72

-

733.55

... More
4th storey

0.13

-

740.85

... More
Cement concrete 1:1.5:3 with stone aggregate 20 mm nominal size for reinforced concrete work in shelves excluding steel reinforcement, but including centering and shuttering, laid in position, complete in all respects. as per HSR 10.81+10.95. (a) (CP @450%) 1st storey

1.85

-

1034.6

... More
2nd storey

1.74

-

1041.9

... More
Cement concrete 1:1.5:3 with stone aggregate 20 mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centering and shuttering , laid in position, complete in all respects. extra over Item Nos. 10.79 to 10.94, if 1:1 ½:3 mix is used, instead of 1:2:4. as per HSR 10.82+10.95. (a) (CP @450%) 1st storey

63.4

-

1084.8

... More
2nd storey

55.73

-

1092.1

... More
3rd storey

3.36

-

1099.4

... More
Cement concrete 1:1 1/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects.extra over Item Nos. 10.79 to 10.94, if 1:1 ½:3 mix is used, instead of 1:2:4 as per HSR 10.86+10.95. (a) (CP @450%) 1st storey

113.5

-

1188.75

... More
2nd storey

44.68

-

1196.05

... More
3rd storey

4.28

-

-

... More
Cement concrete 1:1.5:3 with stone aggregate 20 mm nominal size for reinforced concrete work in fascias parapets and other thin vertical sections, not covered by Item Nos. 10.82, 10.86 to 10.88 not exceeding 10 cm thickness excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects., as per HSR 10.89+10.95. (a) (CP @450%) 1st storey

1.96

-

1708.95

... More
2nd storey

1.96

-

1716.25

... More
Cement concrete 1:1.5:3 with stone aggregate 20 mm nominal size for reinforced concrete work in footings, strips, foundations, beams, rafts, pedestals and approach slabs of bridges etc., excluding steel reinforcement as per HSR 10.90+10.95. (a) (CP @450%)

72

-

774

... More
Damp proof course 40 mm thick of cement concrete 1:1.5:3 using stone aggregate 20 mm nominal size with 2 coats of bitumen 20/30 penetration, at 1.65 kg per sqm laid hot and sanded., as per HSR 10.114 (C.P.@450 %)

50.35

-

38.5

... More
Cement concrete 1:1 ½:3 with stone aggregate 20 mm nominal size in pavements, roads, taxi-tracks and runways, laid to required slope and camber, including consolidation, finishing and tamping complete. extra over Item Nos. 10.79 to 10.94, if 1:1 ½:3 mix is used, instead of 1:2:4 as per HSR 10.132+10.95. (a) (CP @450%)

199.77

-

729.3

... More
First class brick work laid in cement sand mortar 1:6 in foundation and plinth. As per HSR 11.2. (CP @ 600%)

41.86

-

393.45

... More
11.43 cm thick brick wall laid in cement mortar 1:4 without reinforcement in foundation and plinth, as per HSR 11.47 (C.P. @ 600%)

19.02

-

52.7

... More
First class brick tile masonry with 22.86 cmX 11.43 cm X 3.81 cm tiles laid in cement Sand mortar 1:4 in first sorey upto 4 metres above plinth level. (HSR 11.56 + CP @ 600%) 2nd Storey

0.78

-

813.55

... More
3rd storey

2.25

-

821.8

... More
4th storey

0.46

-

830.05

... More
Providing and Laying Autoclaved Aerated (cellular) concrete light weight blocks (As per IS :2185, Part 3) having density of 550 to 650 kg/m3 and comprehensive strength of 4.0 N/mm2 masonary in non load bearing walls using 100mm thick AAC block complete in all respects. (with polymer modified adhesive of reputed make as approved by Engineer-in-charge in super structure) (HSR 11.104)(CP 0%) 1st Storey

94.71

-

480.15

... More
2nd storey

88.58

-

486.8

... More
3rd storey

7.48

-

493.45

... More
11.43 cm thick brick wall laid in cement (HSR 11.48a + CP @ 600%) 1st Storey

94.71

-

55.1

... More
2nd Storey

88.58

-

56.05

... More
3rd Storey

7.48

-

57

... More
Providing and Laying Autoclaved Aerated (cellular) concrete light weight blocks (As per IS :2185, Part 3) having density of 550 to 650 kg/m3 and comprehensive strength of 4.0 N/mm2 masonary in non load bearing walls using 100mm thick AAC block complete in all respects. (with polymer modified adhesive of reputed make as approved by Engineer-in-charge in super structure) (HSR 11.105)(CP 0%) 1st Storey

101.75

-

4129

... More
2nd storey

99.14

-

4186.75

... More
3rd storey

33.76

-

4244.5

... More
4th storey

2.12

-

4302.25

... More
Terracing consisting of tiles 22.86 cm X 11.43 Cm X 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and on other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc., as per HSR 13.13 (C.P.@600%) 2nd Storey

361.42

-

53.95

... More
Top khurra 0.6 m x 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16, as per HSR 13.50 (C.P.@ 240%)

5

-

12.3

... More
Cement concrete 1:1.5:3 gola 10 cm X 10 cm quardrant along junction of roof with parapet wall finished smooth, where specially specified. As per HSR 13.64. (CP @ 240%)

123.63

-

6.03

... More
Providing and fixing PVC Rain water pipe 6kg Pressure of IsI mark in cement mortar during masonry work. As per HSR 13.89. (CP @ 20%) a) 100mm dia PVC pipe 6kg pressure]

77.6

-

182

... More
b) 150mm dia PVC pipe 6kg pressure

108.51

-

336.65

... More
Providing and fixing PVC bend ISI mark. As per HSR 13.90. (CP @ 20%) a) 100mm dia PVC bend

16

-

97.4

... More
b) 150mm dia PVC bend

10

-

165.4

... More
Providing and fixing mineral fibre false cceiling tiles at all heights of size 595 x 595mm of approved texture, design and pattern. The tiles should have humidity resistance (RH) of 99%, light reflectance 785%, thermal conductivity k = 0.052 - 0.057 w/m K, fire performance as per (BS 476 pt - 6 & 7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33mm thick (galvanized @ 120 gsm) comprising of main T runners of 15x32mm of length 3000mm, cross T of size 15x32mm of length 1200mm and secondary intermediate cross T of size 15x32mm of length 600mm to form grid module of size 600x600mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50mm long 8mm outer diammeter M-6 dash fasteners, 6mm diameter fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm, spaced at 1200mm centre to centre along main 'T'. The system should rest on periphery walls/ partitions with the help of GI perimeter wall angel of size 24x24x3000mm made of 0.40mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450mm centre to centre & 40mm long dry wall SS screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the Engineer-In-Charge with or without groves as per HSR 13.92 (CP @ 10%)

62.28

-

700

... More
Base course of floors consisting of 100 mm thick cement concrete 1:8:16 and 100 mm sand or stone filling. As per HSR 14.1. (CP @ 400%)

406.73

-

36.95

... More
Screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping As per HSR 14.4. (CP @ 400%) 2nd Storey

401.48

-

15.35

... More
Conglomerate floor 25 mm thick cement concrete topping 1:2:4 (HSR 14.8 + CP 400%) 1st storey

402.29

-

22.4

... More
2nd storey

302.28

-

22.7

... More
Conglomerate floor 40 mm thick cement concrete topping 1:2:4 (HSR 14.9 + CP 400%) 1st Storey

6.12

-

31.5

... More
2nd storey

8.67

-

31.8

... More
Precast chequered tiles of 20 mm thickness In ordinary grey cement without chips laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry between joints and over the base in floors, treads of steps and landings. As per HSR 14.45.+ Note (CP @ 400%)

106.55

-

111.48

... More
Kotah stone flooring 25m thick in any pattern as specified over 12 mm thick base of cement coarse sand mortar 1:3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing. As per HSR 14.62. (CP @ 250%) Note (i) Single piece of stone to be used in steps of stair (ii) Size of one piece should not be less than 22"x 22"for flooring (iii) Kotah stone with spacer joint 1"wide duly finished with marble chips in white cement (iv) No extra payment will be made on behalf of above Note (i), (ii) & (iii)

99.19

-

201.95

... More
Kotah stone 20 mm thick in skirting risers of steps, dados, pillars and wall facing (lining) in any pattern laid on 12 mm thick cement coarse sand plaster 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing including labour for fixing cramps, dowels and pins etc. As per HSR 14.66. (CP @ 250%)

9.92

-

237

... More
Providing and fixing vitrified tiles of size 600x 600mm of approved make in flooring laid in any pattern as spcefied over base of 20mm thick cement coarse sand mortar 1:3 and jointed with while cement slurry mixed with pigment to match the shade to tiles. NOTE:- Tile shall be of premium quality(first qualit) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT, JOHNSONS & RAK. As per HSR 14.89. (CP @ (-) 15%)

642.65

-

924.3

... More
Providing and fixing Vitrified tiles of size 600x600mm of approved make in skirting /dado laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to matyh the shade to tiles. NOTE:- Tile shall be of premium quality(first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT, JOHNSONS & RAK. As per HSR 14.90. (CP @ (-) 15%)

61.1

-

929.8

... More
Providing and fixing ceramic tiles/ anti skid tiles of size of size 400mm x 400mm or above size of approved make in floors, laid in any pattern as specified over base of 20mm thic cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles. NOTE:- Tile shall be of premium quality(first qualit) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT, JOHNSONS & RAK. As per HSR 14.91. (CP @ (-) 15%)

63.18

-

624

... More
Providing and fixing 1st quality ceramic glazed wall tiles confirming to I.S 15622 (thickness to be specified by the manufacture) of approved make in all colors, shades except burgundy, bottle green black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12mm thic bed of cement mortar 1:3 coarse and jointed with grey cement slurry, including pointing in white cement mixed with pigment of matching shades complete (HSR 14.92) (CP @ 0%) b) Size of ceramic glazed tiles 300X450mm

207.63

-

648.15

... More
Providing & laying baroda green marble stone 17mm and above thick flooring included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white slurry mixed with pigment to match the shade of marble including rubbing and polishing. The sample shall be got approved from Engineer In Charge for all heights/ storey (HSR 14.96 + CP @ 0%)

67.87

-

1281

... More
12 mm thick cement plaster 1:4 As per HSR 15.5. (CP @ 500%) 1st storey

397.44

-

12.7

... More
2nd storey

331.48

-

12.88

... More
3rd storey

201.34

-

13.06

... More
12 mm thick cement plaster 1:6, on walls As per HSR 15.7. (CP @ 500%) 1st storey

484.63

-

10.65

... More
2nd storey

459.99

-

10.83

... More
15 mm thick cement plaster 1:4 on the rough side of single or half brick wall As per HSR 15.10. (CP @ 500%) 2nd Storey

83.53

-

15.65

... More
3rd Storey

100.8

-

15.83

... More
15mm thick cement plaster in 1:6 As per HSR 15.12. (CP @ 500%) 1st storey

593.44

-

13.1

... More
2nd storey

443.7

-

13.28

... More
3rd storey

47.83

-

13.46

... More
10 mm thick cement plaster 1:4 As per HSR 15.52. (CP @ 500%) 1st storey

575.58

-

12.65

... More
2nd storey

444.08

-

12.83

... More
3rd storey

22.6

-

13.01

... More
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete.As per HSR 16.1. (CP @ 230%)

292.08

-

4.6

... More
Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping etc. 1st quality As per HSR 16.2. (CP @ 230%)

292.08

-

3.75

... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. As per HSR 16.3. (CP @ 230%)

408.83

-

9.4

... More
Applying priming coat with metal primer on New steel or iron work including preparation of surface. As per HSR 16.9. (CP @ 230%)

40.58

-

3.15

... More
Distempering with washable oil bound distemper (of approved manufacture) two coats on new work. As per HSR 16.58. (CP @ 230%)

3006.08

-

9.1

... More
Pdg. Two coats of exterior acrylic emulsion paintAs per HSR 16.79. (b) (CP @ 0%) b) 1st quality

1249.68

-

48.75

... More
Providing and applying two coats white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labout charges, scaffolding, sundries etc. Complete (J.K. / Birla make) as per HSR 16.81 (CP @ 230%) b) 1st quality

4186.47

-

11.35

... More
Supplying and fixing hydraulic door Closer, I.S.I mark, with necessary Screws, etc., complete- As per HSR 17.82. (CP @ 300%) C) I.S.I designation no. III (size of door 851 mm to 1000 mm)

15

-

216.5

... More
Factory manufacture solid flush door and Shutters, with block board core as per I.S. No. 1659-1969 bonded with water poof type phenol formal dehyde synthetic resin, hot-pressed, conforming to I.S. 2202 part I and II, fixed in positon includeing iron hinges, screws, chocks/cleats and stops etc. (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position)- as per HSR 17.93. (a) - 17.18. Note (i) (CP @ 165%) commercial veneering with vertical grains or corss bands and face veneer on both sides commercial facing with laminated core and lipped edges:- 35 mm thick

72.75

-

436.15

... More
25 mm thick

48.95

-

387.15

... More
P/F aluminium works for doors & windows ventilators & partition with extruded built up std. tubular sections / appropraiate Z section and other sections of approved make conforming to IS, 733 and IS :1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fastners i/c necessary filling up of gaps at junctions, at top, bottom and sides with reqd. neoprene felt etc. aluminium sections shall be smooth, rust free straight mitred and jointed mechanically wherever reqd. i/c cleat angle. Alumin snap beading for glazing / pancilling C.P. brass / stainless steel screws etc. complete. Shutters of doors, windows & ventilators i/c P/F hinges / pivots and making provision for fixing of fittings wherever reqd. i/c the cost of PVC / neoprene gasket reqd. i/c aluminium fitting as per HSR 17.96. + Note (i) (CP @ 15%)

632.97

-

268.7

... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particles board conforming to IS : 12823 grade 1 type II in paneling fixed in aluminium doors, windows shutters and partition frames with CP brass / stainless steel screws etc. complete. as per HSR 17.97.(CP @ 5%) a) Pre-laminated particle board with decorative lamination o n one side & balancing lamination on both side.

0.35

-

780.3

... More
Providing and fixing glazing in aluminium door, windows, ventilator shutter and partitions etc. with PVC / neoprene gasket etc. complete (cost of aluminium snap beading shall be paid in basic items.) (HSR 17.98 + CP 15%) b) With float glass panes of 5.0 mm thickness.

108.57

-

700

... More
Note (v) Extra for frosted glass 5.0 mm thick

108.57

-

11.5

... More
Iron-grated doors, including pintle hinges and arrangements. as per HSR 18.11 (C.P.@500%)

3.28

-

1224.6

... More
Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. as per HSR 18.12. (CP @ 500%)

14.1

-

1040.35

... More
Fe-500 EQR TMT steel bars for RCC, works, where not including in the complete rate of RCC including bending, binding and placing in position complete. As per HSR 18.22. (CP @ 500%)

452.36

-

927.05

... More
Supplying and fixing glass panes including special metal sash putty of approved make, as per HSR 18.30b, C.P. @ 500% b) glass panes 4 mm thick, exceeding 40 sq dm areas.

23.88

-

115.4

... More
Pressed steel sheet frames ( chowkats), consisting of 2mm thick steel sheet of the specified section, including iron lugs ( hold fasts), iron hinges , confirming to P.W.D. specifications, including bolts for fixing stops, locknotch, provision for receiving tower bolts, and finished with one coat of ready-mixed paint red lead non-setting primer, of approved quality, fixed in position including the cost of cement concrete 1;3:6 for filling in the frame, and cement conc. for lugs complete. as per HSR 18.34. (CP @ 500%) (b) Door and window frame of size 76 mm X 38 mm with 35 mm wide single rebate

187.79

-

58.6

... More
( c) Door and window frame size 127 mm X 50 mm with 40 mm wide double rebate

673.02

-

76.8

... More
d) Door and window frame of size 114 mm X 50 mm with 40 mm wide double rebate.

257.93

-

69.75

... More
Preparation of sub grade, including trenching, rough dressing of spoil final dressing of earth,to given levels and camber, watering, rolling with road roller, and compacting the bed as per HSR 24.1. (CP 370%)

1311.56

-

92.45

... More
Laying brick on end edging lengthwise 22.86 cm deep and 6.83 cm wide including excavation of earth and refilling the excavated soil and compacting along brick edging complete in all respect with other than brick soiling., as per HSR 24.6b (C.P.@ 370%)

218.84

-

0.9

... More
TOTAL CIVIL (HSR PART)

-

-

-

... More
HSR ITEMS (PH work)

-

-

-

... More
Excavation for pipelines running under pressure In trenches and pits, in open areas, where disposal,Of surplus earth is done alongwith the alignment Including trimming & dressing sides, leveling of beds of trenches to Correct grade, cutting joint holes, cutting trees and bushes, etc.,Refilling consolidation and watering of refill in 15 cm layers and Restoration of unmetalled or unpaved surface to ITS ORIGINAL CONDITION, including the cost of dewatering of rain Water, diversion of traffic, night signals, fixing caution boards, watching, Fencing etc., and outside the town in ORDINARY SOIL as per HSR 6.8 (C.P. @370%) a) Without timbering and shorting upto 1.5 metres depth

37.55

-

1030

... More
Excavation of trenches in streets, lanes or in Open areas for storm sewer, sewers running by Gravity nd manholes to full depths as shown In drawings including shoring timbering of Poling boards, frame System type, dressing to correct Sections and dimensions, according to templates and levels, Dewatering, provision for diversion of traffic, cutting trees and Bushes etc. Night signals, profiles, pegs, sight rails, oning rods,Crossing over trenches for access to the houses, watching fencing, Etc., fixing and maintenance of caution boards, refilling of trenches, Watering of refill, in 15 m layers, ramming and restoration of Unmetalled or unpaved surface to original condition and removal Of surplus soil from site of work, upto a lead of 1 Km in ordinary soil., as per HSR6.10a (C.P.@ 370%) (a) For depths of excavation exceeding 3 metres, but not exceeding 4.5 metres

29.63

-

1189

... More
Cement concrete 1 : 4 : 8 with stone aggregate 20 mm Nominal size in foundation and plinth as per HSR 10.38 (C.P.@450 %)

6.01

-

420

... More
Providing and fixing cast iron double flanged sluice valves PN-1.6 marked with IS:14846 i/c nuts and bolts marked with IS:1363 Rubber sheet marked with 638 etc. cariage loading unloading stacking handling Re-handling etc. complete in all respect to the satisfaction of Engineer in -Charge ( Makes AARKO,VENUS,LEADER, SI , PANJA, UPADHAY, as per HSR 28.10 (C.P.@10%) 100mm dia

2

-

3698

... More
P/F CAST IRON DOUBLE FLANGED SWING CHECK TYPE REFLUX (NON RETURN VALVE PN-1.6 MARKED WITH IS:5312 including nuts bolts marked with IS :1363,Rubber sheet marked with IS:638 etc. carraige, loading, unloading, stacking, handling, rehandling etc. complete in all respect to the satisfaction of Engineer - in charge (makes AARKO, Venus, Leader, BIR, Panja, Upadhay) as per HSR 28.10a (C.P.@10%) 100 mm i/d

2

-

3362

... More
DRILLING AND TAPPING CAST IRON PIPE LINES OF ALL DIAMETERS AND SCREWING IN FERRULE AND CONNECTIONS as per HSR 28.22 (CP @ 300%) C) 20 mm internal diameter

4

-

29.85

... More
CUTTING HOLES UPTO 23 CM SQUARE THROUGH STONE MASONARY OR BRICK WORK IN CEMENT WALLS FOR PIPES AND MAKING GOOD INCLUDING REPOINTING REPLASTERING AND FINISHING according to existing finish where required., as per HSR 28.24 (C.P.@300%) a) 11.43 cm

19

-

14

... More
b) 22.86 cm

29

-

20.35

... More
BAILING OUT WATER FROM THE TRENCHES FOR MAKING NEW CONNECTIONS IN FULLY CHARGED PIPE-LINES including cleaning, trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge as per HSR 28.47 (CP @ 300%) SIZE OF THE MAIN WITH WHICH CONNECTION IS TO BE MADE:- upto 200 mm internal diameter.

4

-

67.5

... More
Providing and fixing steel bar emdedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification, in pump chamber, main hole etc. having minimum 3mm thick polypropylene polymer confirming to IS: 10910 encapsulated on 12mm dia ribbed steel bars per IS : 1786,the rate including rate of setting the same to thec orrect lines and levels during embedded in 1:2:4 cement concrete including carriage, loading, unloading, stacking, handling, rehandling, etc. complete in all respect to the Engineer in charge.as per HSR 29.28 (CP @ 120 %)

15

-

90

... More
Masonry Chambers. CONSTRUCTION BRICK MASONRY INSPECTION CHAMBER SIZES AS GIVEN BELOW UPTO 0.60 METRE AVERAGE DEPTH in cement mortar 1:5 LIMECONCRETE with 40 percent lime mortar 2:3 in foundation cement concrete 1:2:4 BENCHING 12mm THICK CEMENT PLASTER 1:2 with a floating coat of 1mm thick of neat cement, R.C.C.1:2:4 SLAB 100mm THICK /C.C.TOPPING 50 mm THICK WITHOUT 455 MM x455MM/455MMx610MM INSIDE LIGHT DUTY C.I. INSPECTION CHAMBER COVER AND FRAME weight as per I.S.I. specification painted WITH 3 COATS OF black bitumastic superior paint complete as per standard design but incl SFRC frame and cover as directed by engr-in-charge . (HSR29.84 + CP 450%) (a) Size 450 mm x 450 mm inside

4

-

414

... More
b) Size 450 mm x 600 mm inside

5

-

582

... More
c) Size 600 mm x 900 mm inside

4

-

690

... More
EXTRA FOR EVERY 0.30 METRE DEPTH OF INSPECTION CHAMBER as per HSR29.85 (C.P.@ 450%) 600 mm x 900 mm

2

-

139

... More
Providing & fixing SFRC MANIHOLE COVERS AND FRAMES MARKED WITH IS:12592 including setting the same to correct lines and levels in 1:2 cement sand motar over manhole including carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction to the Engineer-in-Charge. as per HSR 29.94 (CP @5%) b) Type :-Extra Heavy Duty Set (HD-20)-560MM Clear Opening

4

-

1100

... More
Providing salt glazed stone ware pipes grade 'A' in standard length of 600mm each pipe marked with IS:651 and their lowering, cutting, jointing and testing as described in HSR item no 29.38, 29.39, 29.40 i/c the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, rehandling etc. complete in all respect to the satisfaction to the Engineer-in-charge, as per HSR 29.95 (C.P.@ 5%) 150mm

60.96

-

199

100

-

253

... More
PROVIDING AND FIXING IN POSITION BESTINDIA MAKE LARGE FLAT BACK or Angular lipped from Urinal 610 MM HIGH consisting of: Flat back lipped or angular urinal basin or VITREOUS CHINAWARE EXCLUDING 5 LITRES CAPACITY mosquito proof INDIAN MAKE C.I AUTOMATIC flushing CISTERN painted with non- Yellowing white enamel paint or other approved shade Enamel paint on outside and superior black britumastic Paint on inside with screwed 15 mm pipe., AS PER HSR item no. 30.25DVD (White) (CP @ 0%)

4

-

595

... More
Providing and fixing VITREOUS CHINAWARE PARTITION PLATE for urinal as per HSR 30.40(C.P.@ 340%) (I) SMALL SIZE 680 mm x 330 mm (i) White

4

-

200

... More
PROVIDING AND FIXING IN POSITION INDIAN MAKE (ORDINARY) LAVATORY SUITES Consisting of Lavatory in VITREOUS CHINAWARE size as given Below (to the approval of the Engineer-in-charge) including china plug for tap hole where necessary; R.S or C.I BRACKETS for building into wall including Painting;32 mm C.P BRASS WASTER WITH C.P brass chain and rubber plug; 15 mm C.P BRASS SCREW DOWN PILLAR TAP WITH Jamnuts or couplings best design ( as approved by the Engineer- In-charge)ALL FITTINGS BEST INDIAN MAKE and; to the approval of the Engineer-in-charge. ALL brass work chromium plated and COMPLETE in all respects INCLUDING cutting and MAKING GOOD THE WALLS FLOORS AND PAINTING OF FITTINGS ETC.as per HSR 30.41 (iv) (C.P.@ 340%) Whiteiv) Size 550 mm x 400 mm with one no. tap

7

-

407

... More
Providing and fixing in position Indian make Pedestal fittings of vitreous Chinaware complete as required by the( Engineer- in- Charge) as per HSR30.44 (i) (C.P.@340%) White

7

-

279

... More
Providing and fixing in position best Indian make C.P brass basin mixer complete instead of one no pillar tap. (HSR 30.46a) (CP @ 340%)

3

-

257

... More
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE SHOWER WITH 15 OR 20 I/D INLET. (c) C.P brass with revolving joint (HSR30.66) + CP340%)

5

-

122

... More
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE TOWEL RAILS FIXED in with rawlslugs embedded in walls with C.P brass screws. Complete in all respect INCLUDING CUTTING AND MAKING GOOD THE WALLS ETC. as per HSR 30.68 (C.P.@ 340%) b)20 MM DIA C.P BRASS (ii) 600 mm long.

4

-

57

... More
Providing and fixing in position best Indian make Soap dish fixed into wall with C.P brass screws and complete in all respects including cutting and making good the wells etcs., as per HSR 30.70a(i) (C.P.@ 340%) a) C.P. brass (ii) Soap dish Small

9

-

46.5

... More
Providing and fixing in position 15 mm i/d C.P brass bib Cocks of best quality (as required by Engineer-in-charge), as per HSR 30.75 (C.P.@ 340%). a)Bib cock long body

19

-

116

... More
c) Bib cock

11

-

100

... More
Providing and fixing in position C.P brass stop cocks (as Approved by the Engineer-in-charge), as per HSR 30.76 (C.P.@ 340%) a) 15 MM STOP COCK(i) Stop cock male and female end

19

-

101

... More
a(ii) Concealed stop cock with flange

17

-

130

... More
PROVIDING AND FIXING LEAD INLET CONNECTION WITH BRASS UNION FOR FLUSHING AND WARNING PIPES COMPLETE IN ALL RESPECTS.as per HSR 30.93c (C.P.@ 300%) c)15 mm alkahene pipe inlet connection ,

14

-

10.5

... More
CUTTING CHASE IN BRICK WALLS IN CEMENT OR IN FLOOR FOR EMBEDDING G.I OR H.C.I PIPE LINES AND MAKING GOOD THE SAME TO ITS ORIGINAL CONDITION (LR), as per HSR 30.95c (C.P.@340%) c) size 75 x 50mm

107.67

-

4

... More
PROVIDING AND FIXING IN POSITION AUTOMATIC BRASSBALL VALVES IN TANKS, as per HSR 30.110 (C.P.@ 340%) b) With Plastic ball ii) 20 mm internal diameter

5

-

48

... More
PROVIDING AND FIXING IN POSITION UPVC GULLY TRAPS FIXED IN CEMENT CONCRETE 1:4:8 complete WITH H.C.I GRATING 150 MM X 150 MM CAST IRON COVER WEIGHING APPROXIMATELY 7.26 KG AND FRAME CLEAR OPENING 300 MM X 300 MM and outside size 330 mm x 330 MM AND CHAMBER INCLUDING cost of all brick work in CEMENT MORTSAR 1:5 CEMENT CONCRETE 1:8:16 IN FOUNDATIONS AND CEMENT CONCRETE 1:2:4 IN COPING around C.I cover and frame etc. WITH THREE COATS of black bitumastic superior PAINT of approved manufacture on all C.I work AS PER STANDARD DESIGN, minimum depth of water should be 150 mm with a minimum seal 50 mm., including 110 mm internal diameter S.W. R. gully trap, as per HSR 30.114 (derived rate), C.P. @ 0%

7

-

978.6

... More
P/F HDPE water storage tank of Sintex, Diplast, O.K., Supreme make with cover / lids marked with ISI 12701 on roof top of building i/c cost of hoisting and placing in position, making connections with inlet and outlet pipe, providing overflow and scour provision with suitable plug on scour pipe i/c cost of nipples, washers, flanges for connection in tank, complete in all respect to the satisfaction of Engineer in- charge (except civil work)., as per HSR 30.119 (C.P.@ 0%) 500 Ltr.

1

-

2683

... More
1000 Ltrs.

4

-

5263

... More
TOTAL (PH HSR PART) = RS.

-

-

-

... More
DSR PART

-

-

-

... More
Providing and fixing aluminium sliding door bolts, ISI marked anodised (DSR 9.96) (Powder coated) Note:- no extra payment will be made for powder coating Sliding bolt 300x16mm (DSR 9.96.2)

3

-

212.45

... More
Sliding bolt 250x16mm (DSR 9.96.2)

37

-

189.2

... More
Tower bolt 200 x 10mm (DSR 9.97.3)

41

-

76.15

... More
Tower bolt 150 x 10mm (DSR 9.97.4)

257

-

64.3

... More
Tower bolt 100 x 10mm (DSR 9.97.5)

148

-

49.2

... More
Handles125mm (DSR 9.100.1)

88

-

51.1

... More
Handles100mm (DSR 9.100.2)

139

-

45.1

... More
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to equired colour and shade, with necessary screws etc. complete. (DSR 9.101)

45

-

38

... More
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. Twin rubber stopper (DSR 9.114) Double strip (horizontal type)

16

-

21.5

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite of any colour and shade (8.2.2.) Area of slab upto 0.50 sqm

9.44

-

3351.95

... More
Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. (DSR 12.38) 100 mm diameter

24

-

167.35

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (DSR 17.1) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

3

-

3494.2

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Semi rigid pipe 32mm dia

9

-

75.6

... More
40mm dia

9

-

81.4

... More
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etccomplete (DSR 17.78)

11

-

9685.7

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall (DSR 18.7) 20 mm nominal outer dia. Pipes.

43.8

-

179.95

... More
25 mm nominal outer dia .Pipes.

69.59

-

216.2

... More
32 mm nominal outer dia. Pipes.

36.2

-

289.05

... More
40 mm nominal outer dia. Pipes.

62.6

-

385.5

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. (DSR 18.8) 20 mm nominal outer dia .Pipes.

43.8

-

284.85

... More
25 mm nominal outer dia .Pipes.

69.59

-

333.6

... More
32 mm nominal outer dia .Pipes.

36.2

-

412.9

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work (DSR 18.9) 20 mm nominal outer dia. Pipes.

21.9

-

149.3

... More
25 mm nominal outer dia. Pipes.

69.59

-

191.65

... More
32 mm nominal outer dia. Pipes.

18.1

-

250.55

... More
40 mm nominal outer dia. Pipes.

94.78

-

321.15

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (DSR 18.12) 15mm dia nominal bore

20

-

160.2

... More
20mm dia nominal bore

20

-

186.3

... More
25 mm dia nominal bore

20

-

205.85

... More
32 mm dia nominal bore

20

-

247.4

... More
40 mm dia nominal bore

20

-

301.05

... More
Providing and fixing gun metal gate valve with C.I. wheel/Arm of approved quality (screwed end) : (DSR 18.17) 20 mm nominal bore

8

-

396.55

... More
25 mm nominal bore

2

-

428.2

... More
32 mm nominal bore

3

-

500.75

... More
40 mm nominal bore

7

-

584.7

... More
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : (DSR 18.47) 15 mm nominal bore.

5

-

366.2

... More
20 mm nominal bore

13

-

389.45

... More
25 mm nominal bore

2

-

424.3

... More
32 mm nominal bore

3

-

459.15

... More
40 mm nominal bore

7

-

517.2

... More
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. (DSR 18.53A)

49

-

41.4

... More
Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 : (DSR 18.72) 100 mm dia Ductile Iron Class K-7 pipes

50

-

926.3

... More
Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.as per DSR 22.23A

501.77

-

368.2

... More
TOTAL (DSR PART)

-

-

-

... More
CIVIL (NS PART)

-

-

-

... More
Earth filling with the earth brought from outside the campus irrespective of any lead, including laying in 15cm in layers, watering and consolidating complete in all respect and fully satisfaction of Engineer-in-charge.

11885.16

-

189

... More
Finishing of the laid cement concrete with vacuum dewatering system, surface vibrator and fine trowel complete in all respect (Trimix)

1311.56

-

60

... More
Making groove 5x50mm deep in CC road for expansion joints complete in all respect.

468.47

-

28

... More
Making and cutting hole 100mm to 125mm dia in RCC through core cutting machine complete in all respect.

9

-

689.6

... More
Supply of first class kiln bricks at site

900

-

4500

... More
Labour charges for chasing brick work upto 150mm height and 12mm deep for fixing skirting in tiles, finished with plaster level

706.1

-

26.45

... More
Extra for nosing in marble stone for treads (NS)

93.42

-

110

... More
Extra for Granite polish on Kota stone flooring (NS)

99.19

-

49

... More
Providing and fixing in position best quality stainless steel sink (Glossy) with complete fitting (Jayna make) Size 45” x 20” with 2 nos. bowls of size 20” x 16”,8”, Model DBF-02.

1

-

10995

... More
Providing and fixing stainless steel railing and grills of standard size and designs desired by Engineer in charge made of 304 grade i/c fixing at site finishing complete i/c cost of all required accessories complete in all respect (DSR 10.28)

307.93

-

472.4

... More
Pdg & fixing mumty door shutter manufactured from MS sheet and angle iron frame etc. complete in all respect.

90

-

74.35

... More
Providing & fixing in position SS 20mm dia hanging rod (oval shape) heavy quality i/c SS wall to wall clamp complete in all respect

16.69

-

272

... More
Applying exterior primer on exterior surface complete in all respect

1249.68

-

25.7

... More
Providing and fixing MS rod 8mm fully threaded with nut bolts and washer inserted in aluminum sections, window & door shutters, complete in all respect.

36

-

136

... More
Providing and Fixing 4mm thick ACP sheet for exhaust fan complete in all respect.

11.15

-

1948

... More
Extra for making hole in working slab for gas pipe etc. including finishing complete

1

-

46

... More
Providing & fixing acrylic sheet 4mm thick complete in all respect

11.15

-

1066

... More
Providing and fixing aluminium fitting ISI marked anodized (anodic coating not less than grade AC-10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete in all respect (powder coated) Sliding bolt 200 x 16

8

-

189.7

... More
Sliding bolt 150 x 12

5

-

109.6

... More
Folding Handle, 100mm

78

-

85

... More
Eye Hook

74

-

20.7

... More
Hasp & Staple 150mm

33

-

20

... More
Providing & fixing stainless steel wire mesh jali of 22 gauge & 304 grade in alumanium door &window in alumanium section including pvc/neoprone gasket &labour for fixing etc(excluding the cost of bidding,channel etc same will be paid in aluminium work.

108.57

-

800

... More
Applying 12mm thick plastering in CM 1:4 on corbelling complete in all respect to the entire satisfaction of EIC.

123.47

-

119

... More
P/F 25mm thick red stone finised both sides for cupboard shelves and parition including slightly round edges complete in all respect

40.67

-

754

... More
Providing & fixing Zinc coated clamp i/c cost of 12 mm screwed G.I. rod & fastener complete in all respect having dia 110mm / 90mm dia

10

-

237

... More
P/F of coat with 5no. hook for hanging of cloth complete in all respect (NS)

44

-

75.7

... More
P & F in position factory manufactured 50mm thick jali with cement sand concrete ratio 1:1.5:3 by using 1.6mm dia steel fixed in position in ducts upto height of 42 fts, complete in all respect

15.61

-

650

... More
Providing & fixing Chiken mesh / Fabric Jali (app. 200 kg per 200 ft/ as per specification with nall and washer on wall, columns and beams etc. before applying plaster to avoid cracks at junction and intermediate of wall complete in all respect (NS)

828.7

-

42

... More
Supplying, laying and consolidation of stone metal 53mm to 22.5mm wearing coat, to water-bound-macadam specification, including making side dowels,carrying the metal from stacks and spreading to templates, screening and spreading the binding material, and consolidating the stone metal and blinding material, to proper camber, with road roller, excluding the cost of templates, barriers, and lighting arrangement and chowkidars.

133.18

-

1539

... More
Providing and laying Granular sub base with coarse graded material as per approved specification including cost of mechanically mixing, carriage, laying, compaction, watering and rolling complete in all respect to the entire satisfaction of Engineer in Charge.

199.77

-

1160

... More
Turfing of lawn with planting of selection No. 1 superior quality grass with machinery including ploughing the land leveling and dressing applying farm yard manure in 2.5 cm layer , application of insecticide / pesticide to safe guard against soil borne diseases (CSR 32.21+CP@15%)

464.5

-

48.94

... More
Providing and Planting different type of plant i/c digging,watering,manour,fertilizing etc complete in all respect Palm

20

-

798.03

... More
Silivock

5

-

147.99

... More
Washing Lown

5

-

2294.75

... More
Murraye

4

-

22.35

3

-

1016.53

... More
Ficass

10

-

229.93

... More
Phonix Polk

10

-

339.18

5

-

213.54

... More
Altimes

8

-

180.76

... More
Song jodis

5

-

55.13

... More
Phoried

7

-

1256.88

... More
Ju pire

7

-

322.79

... More
Chand mirror

5

-

126.14

... More
Fursina

5

-

311.86

... More
TOTAL CIVIL (NS PART)

-

-

-

... More
PH (NS PART)

-

-

-

... More
Pdg. & fixing SWR PVC pipe type ‘B’ and specials ISI marked including fitting joint solvent mixture complete in all respect- a) 110mm dia pipe

75.72

-

315.95

... More
Special for 110mm dia pipe Coupler / Socket

19

-

86.55

5

-

29.25

15

-

28.8

... More
Plain bend

10

-

106.85

... More
Single junction with door / Tee

4

-

169.15

... More
P trap

6

-

269.8

... More
b) 90mm dia pipe

32.77

-

261.3

... More
Special for 90mm dia pipe Cowl

6

-

25.4

15

-

28

... More
Coupler / Socket

10

-

72.9

... More
Single junction with door

4

-

141.15

... More
Floor trap

18

-

108.85

... More
Plain Bend

5

-

90.95

... More
P/F in position 100mm dia C.P. Jali (openable) on floor trap of approved make (Viking, Chilli, Camry), heavy quality

18

-

200

... More
P/F in position C.P. flange

49

-

15

... More
Pdg and Fixing in position 5mm thick looking mirror with screws i/c cost of synthetic wood beading of brown water proof ply of 6 mm thickness complete in all respect.

8.08

-

2863

... More
P&F in position oval shaped under / over counter wash basin make CERA including cost of 32mm dia C.P. waste complete in all respect.

5

-

2061

... More
Supply & erection of 1 no. submersible motor 1.5 HP of approved make with starter complete in all respect

1

-

20870

... More
TOTAL NS. (P.H.) =

-

-

-

... More
BOUNDARY WALL PORTION

-

-

-

... More
Earth work in excavation in foundations, trenches, etc. in all kinds of soils, not exceeding 2 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 metres. (HSR 6.6 + CP 425%)

78.7

-

1108.1

... More
Cement concrete 1 : 8 : 16 with stone aggregate 40 mm Nominal sie in foundation and plinth. (HSR 10.28 + CP 450%)

19.67

-

318.65

... More
Cement concrete 1:1-1/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects (HSR10.86+10.95) (CP450%)

94.36

-

1188.75

... More
Cement concrete 1:1-1/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work in footings, strips, foundations, beams, rafts, pedestals and approach slabs of bridges etc., excluding steel reinforcement but (HSR10.90+10.95)(CP450%)

28.12

-

774

... More
First class brick work laid in cement sand mortar 1:4 in foundation and plinth., as per HSR 11.4 (C.P.@600%)

65.95

-

424.6

... More
First class brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level. as per HSR 11.9 (C.P.@600%)

131.91

-

445.6

... More
12 mm thick cement plaster 1:4 as per HSR 15.5 + CP 500%)

1287.29

-

12.7

... More
15 mm thick cement plaster 1:4 on the rough side of single or half brick wall (HSR 15.10 + CP 500%)

1287.29

-

15.65

... More
Pdg. Two coats of exterior acrylic emulsion paint (HSR 16.79(b) + CP Nill%)

2574.58

-

48.75

... More
Providing and applying two coats of white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete (HSR 16.81 + CP 230%)

2574.58

-

11.35

... More
Iron-grated doors, including pintle hinges and arrangements. as per HSR 18.11 (C.P.@500%)

5

-

1224.6

... More
Fe 500 EQR/tor steel) bars for R.C.C. works/tor steel) bars for R.C.C. works, where not included in the complete rate of R.C.C including bending, binding and placing in positon complete. , as per HSR 18.22(C.P.@ 500%)

116.07

-

927.05

... More
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m) having 50 no rounds per 6 metre length, upto 3m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) /Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) (DSR 16.53)

378.86

-

255

... More
Applying priming coat with exterior primer before provided weather shield exterior paint on outer walls on plastered/Brick surface (NS item)

2574.58

-

25.7

... More
TOTAL BOUNDARY WALL (NS PART)

-

-

-

... More
RAIN WATER HARVESTING SYSTEM

-

-

-

... More
Excavation for pipelines running under pressure In trenches and pits, in streets & lanes including Trimming and dressing sides, leveling of beds of trenches to correct Grade, cutting joint holes, cutting rrees and bushes etc., refilling Consolidation and watering of refill, in 15 cm layers and Restoration of unmetalled or unpaved surfcae To its original conditon, including the cost of dewatering Of rain water, diversion of traffic, nigh signals, fixing caution boards, Crossing over trenches for access to the houses, washing, financing, etc.,And disposal of surplus soil outside and inside theTown involving lead upto one km in ordinary soil. (HSR 6.9 + CP 370%) a) without timbering and shoring upto 1.5 metres depth

15.75

-

1183

... More
b)with timbering and shoring: ii) Exceeding 1.5 metres dept, but upto 2.25 metres depth.

7.88

-

1623

... More
iii) Exceeding 2.25 metres depth, but upto 3.00 metres depth.

7.88

-

1748

... More
vi) Exceeding 3 metres depth, but upto 4.5 metres depth

10.5

-

1868

... More
Earth work in excavation in foundations, trenches, etc. in all kinds of soils, not exceeding 2 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 metres. (HSR 6.6 + CP 425%)

15.66

-

1108.1

... More
Earth filling under floors with surplus soil, excavated from foundation and taken only from outside the building plinth, in 15 cm layers, including ramming watering and consolidating lead upto 30 metres. (HSR 6.13 + CP @ 370%)

40

-

343.4

... More
Cement concrete 1 : 4 : 8 with stone aggregate 20 mm Nominal size in foundation and plinth. (HSR 10.38 + CP @ 450%)

0.35

-

420

... More
Cement concrete 1; 2 ; 4 with stone aggregate 20 mm nominal size in foundation and plinth. (HSR 10.41 + CP @ 450%)

0.1

-

615.6

... More
First class brick work laid in cement, stone dust (from crusher) mortar 1:5 in foundation and plinth. (HSR 11.23 + CP @600%)

0.9

-

427.7

... More
12 mm thick cement plaster 1:3 with Cement rendering on plaster 1 mm thick. (HSR 15.4 + 15.75) (CP @ 500%)

3

-

-

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. (DSR 23.1.1.1) All types of soil 300 mm dia

30

-

370.7

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (DSR 23.3.2) b) 150 mm nominal size dia

18

-

572.3

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (DSR 23.4.2) 150 mm nominal size dia

12

-

529.35

... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer- in-charge. (DSR 23.8)

3.18

-

1175.6

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR 23.5)

1.19

-

921.9

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge. (DSR 23.7)

1.39

-

1038.05

... More
Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. (DSR 23.12)

5

-

542.2

... More
Providing and fixing of non woven Geotextile having thickness of 400 gsm, having minimun tear Strength of 250 ASTM D4533, width wise at least 215 ASTM D4533 having puncture strength of 1550 plus as per ASTM D6241 Having elongation at Break % of 57 plus as per ASTM D 4595 in Two layers, made out of long fibers to hold the modules including cutting, sizing, heat welding and needle punched for high porosity and proper percolation. Complete as per entire satisfaction of engineer-in-charge Formula : 2X (2(LxB)+2(BxH)+2(HxL)) Layers+25% overlap (NS)

70

-

675

... More
Providing & Fixing of Co-polymer based rainwater harvesting structure including supply of crosswave of size 494 mm x 494 mm x220mm with minimum void ratio of 94.7% having a weight of 1.8 kg and spacers having size of 988 mm x 240 mm x 25 mm having a weight of 0.8 kg of approved make and arranging the same in as directed by the engineer-in-charge and in complete accordance to the design, drawings as per entire satisfaction of Engineer -in-charge (NS)

10

-

16650

... More
Providing and fixing of CGWB/GRIHA approved Pure Rain Filters with extensions as required desilting suspended solid catcher made out of FRP and strainers including bucket of SS 304 grade with long fiber foam size around 600mm dia, filtration capacity 40 kiloliters per hour with porosity of 600 microns filter complete in accordance to the desgin , drawing and specification complete as per entire satisfaction of Engineer-in-Charge. Size of FIlter 780 mm Dia, 800 mm height (NS)

1

-

76500

... More
Supplying and fixing of 300 mm supreme UPVC Pipe 315mm O/D conforming toI.S 4985-81 Dated-12/12/2013,I.S marked having 6 KG per centimeter square Pressure i.e. excavation, refilling for providing proper loop from catch pit to filter /filter to cross wave as per entire satisfaction of Engineer in charge. (from chamber to Filter to tank) (NS)

6

-

2700

... More
Providing and Fixing of Medium Duty SFRC cover of required size with perforated slots over gully chamber. All as per requirments and direction of Engineer-in-charge. (NS)

1

-

2300

... More
TOTAL (RAIN WATER HARVESTING SYSTEM)

-

-

-

... More
E.I. (HSR PART)

-

-

-

... More
Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections.(HSR 31.12) (CP 60%) i)15 amp.to 60 amp. 415 V ,10 KA 3-phase.

2

-

1926

... More
ii)100 amp.to 220 amp.415 V,10 KA 3-phase.

2

-

4246

... More
a) Miniature circuit breakers of 9KA breaking capacity HSR @ 31.17ii) SP MCB 6 to 32 Amp

60

-

95

... More
ii)TP MCB of 9 KA breaking capacity 40 amp. to 63 amp.

2

-

377

... More
iii)SPN MCB of 9 KA breaking capacity 40 amp. to 63 amp.

1

-

197

... More
iii)TPN MCB of 9 KA breaking capacity 40 amp. to 63 amp.

2

-

499

... More
Supply & Erection of fitting and accessories (HSR 31.18) (CP 200%)xi)Bakelite angle / straight button holder large size.

24

-

6.2

... More
xxvi ) S/E of hexagonal MS Box 1.6mm thick, 8cm, 7.5cm deep top covered with MS lid by means of screws i/c 10mm dia 30cm long MS rod into suitable suspension hook &bottom covered with 3mm thick bakelite sheet, erected in RCC Slab complete.

33

-

26.3

... More
xvii)ceiling rose flush/surface type

14

-

4

... More
xxx)Supply and erection of PVC pipe of 6 kg. pressure laid 1 metre below ground level complete including digging refilling of the trench with jointing etc. (HSR 31.21) (CP 350%) a)PVC pipe 120 mm dia.

80

-

59

... More
b)PVC pipe 65 mm dia.

40

-

31

... More
Earthing(HSR 31.22) (CP 350%)iii)Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.

6

-

453

... More
iv)Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) comlete as equired.

1

-

1149

... More
v)Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode.

7

-

186

... More
x)Pdg. and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required .

5

-

155

... More
xi)Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required .

30

-

65.1

... More
xiv)Pdg. and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required with all labour and material.

15

-

117

... More
xv)Pdg. and fixing 25 mm x 5 mm G.I. Strip on surface or in recess for connections etc. as required with all labour and material.

60

-

20.3

... More
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . (HSR 31.26) (CP 140%) xxvii)50 Sq. mm 3.5 Core Cable . (armoured)

120

-

74.7

... More
xli)25 Sq. mm 4 Core Cable . (armoured)

60

-

56.3

... More
Supply and erection of 32 mm dia meter 1.5 metre long bracket ( B-Class ) making an angle of 10 to 15 degree with horizontal plane for mounting street light fitting fixing of GI bracket on wall with 2 Nos. , 32 mm x 3 mm thick MS clamps including the cost of cutting , welding of GI pipe complete with cement sand mixture , bolts and nuts etc. including necessary connections .(HSR 31.30) (CP 270%)

8

-

102

... More
S/E of PVC unsheathed copper conductor cable single core 1100 V grade in existing pipe of suitable size excluding cost of pipe.(HSR 31.40) (C.P 10%) (i) Size 1.50 Sqmm

2500

-

10.2

... More
(iii) Size 4.00 Sqmm

800

-

24.5

... More
(vi) Size 16.00 Sqmm

80

-

83.7

... More
S/E of double door sheet steel enclosure distribution suitable for MCBs and ELCBs etc. recessed in wall i/c board with all labour and material required to complete the job in all respect upto to the entire satisfaction of the EIC of the work (HSR 31.41)(CP 10%) vi)8-way , SP&N ( Horizontal) (8+24)

1

-

870

... More
vi)8-way , TP&N ( Horizontal) (8+24)

2

-

2100

... More
P/F Modular type accessories of approved make in existing box including fixing and making necessary connection, complete in all respect. (HSR 31.56) (C.P. 0%)10 amp. 1 way switch

45

-

87

... More
10 amp. Socket

45

-

106

... More
fan regulator

33

-

397

... More
Blanking plate.

200

-

25

... More
Call Bell

2

-

99

... More
P/F GI concealed sheet metal boxes with inner and outer face plate i/c concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required to complete the job in all respect.(H.S.R.-31.57) (C.P. 0%) i)1 & 2 Modules

29

-

101

... More
Supply and erection of PVC pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-charge of work. (H.S.R.-31.58) (C.P. 0%) i)PVC pipe of 32mm dia

60

-

45

... More
Supply installation testing and commissioning of wall / free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2mm thick CRCA sheet, required hardware, 3mm thick bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel, dully painted by 2 coat of zinc / Red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU / Neoprene rubber gasket of not less than 3mm thickness, separate detachable gland plate MS base channel, hinged door with inter locking arrangement for equipment / switch gear.Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3mm thick for separately cable alley to BBC from switch chember. Extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The panel will be complete with control wiring (copper) and fuse protection. (only outer area on all sides shall be measured). Size 1800x1300x450mm deep.(H.S.R.-31.63) (C.P. 0%)

6

-

2160

... More
Supplying and fixing of Copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending , cutting in required shape and size and insulation with colour coding heat shrinkable PVC insulation Complete in all respect.(H.S.R.-31.64) (C.P. 0%)

25

-

525

... More
Pdg. and fixing digital metering equipment for LT cubical Panel consisting of 96mmx96mm 0-500V, volt meter with selector switch, Amp. meter (of required ratio up to 600/5 amp.) with selector switch and required C.Ts 3 Nos., a set of 3 no phase indicating lamps RYB LED..(H.S.R.-31.65) (C.P. 0%)

1

-

4050

... More
Supply & fixing of rotary handle for on / off operation of existing MCCB in the LT panel including fixing the same in position with all labour and material required to complete the job in all respect..(H.S.R.-31.66) (C.P. 0%)i)up to 125A MCCB

4

-

675

... More
ii)Above 125A MCCB

1

-

790

... More
S/E of mark double walled corrugated (DWC) HDPE pipe laid 1 mtr. below ground level including diging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-incharge of the work H.S.R.-31.67) (C.P. 0%) i)HDPE pipe 63 / 50mm outer dia / inner dia.

50

-

95

... More
Supply and erection of moulded case circuit breakers Four pole on wall or on existing pedestal including bonding to earth and necessary connections.(HSR 31.69) (CP 0% ) .v)Four pole MCCB 100 amp of 25 KA breaking capacity.

2

-

5347

... More
vi)Four pole MCCB 200 amp of 25 KA breaking capacity.

1

-

10500

... More
Supply and Erection of 4 pole ON LOAD changeover load breker switch comprising of switches 63 amp to 400 amp suitable for operation on 415 V 50 Hz AC supply complete with handle assembly having door interlock &padlocking arrangement on existing panel / including making necessary connections with petty material required to complete the job.(HSR 31.74) (CP 0%) iii)200 amp 4 pole ON load change over switch

1

-

11000

... More
Supply & Laying of multicore telephone wire 0.51 sqmm bright annealed copper conductor PVC insulated & sealed in existing pipe / channel including all labour and material required to complete the job in all respect.(HSR 31.78) (CP 0%).i) 2-pair telephone wire

1200

-

7.94

... More
S/E/T/C of Cat- 6 cable in existing PVC conduit/ PVC channel complete in all respect with all labour and material required to complete the job in all respect.(HSR 31.80) (CP 0%).

1200

-

28.5

... More
TOTAL HSR (E.I.)

-

-

-

... More
NS. (E.I. PART)

-

-

-

... More
Wiring in 1.5 sqmm PVC insulated copper conductor cable, single core, 1100 volts in 25mm dia PVC pipe, Heavy gauge, ISI mark with modular accessories and GI sheet steel modular boxes of required size with modular inner & outer face plates complete (recessed type). I,) Fan Point b) Medium Point

26

-

500

... More
(c) Long point

7

-

698

... More
(II) Light Point :- (a) short point

9

-

305

... More
(b) Medium point

45

-

473

... More
(c) Long point

71

-

671

... More
VII) 5 Pin, 5 AMP plug point including earthing the 3rd pin with 1.5 sqmm copper insulatd earth wire (a) short point

26

-

463

... More
(b) Medium point

4

-

665

... More
(c) Long point

26

-

902

... More
VIII) 5 Pin, 15 AMP plug point including earthing the 3rd pin with 1.5 Sqmm copper insulated earth wire & wiring with 4 Sqmm copper wire (b) Medium point

1

-

1018

... More
(c) Long point

28

-

1420

... More
(iv) Call Bell Point with bell push :-(c) Long point

2

-

686

... More
(iii) Twin Control Light Point with 2 way 10 amp switch:-(b) Medium point

1

-

545

... More
c) Long Point

4

-

782

... More
Supply & Erection of 20 watt 4000K LED indoor batten type tube light with alumunium extrusion ,4 feet long complete in all respect i/c making necessary connections.

19

-

566

... More
Supply & erection of LED Batten 10 W 2 Feet complete in all respect.

2

-

442

... More
Supply and erection of 36W surface/ recess mounting 2'x2' energy efficient LED 6000 K luminaire suitabele for single phase A.C. 230 V, 50 Hz supply, complete in all respect including making necessary connections etc.

33

-

3327

... More
S/E of 15/18 watt recess/ surface mounting energy efficient LED 6000K luminaire suitabele for single phase A.C. 230 V, 50 Hz supply, complete in all respect including making necessary connections etc.

32

-

1864

... More
S/E LED 48/45 watt, 6 K die cast aluminium street light luminaire complete with all job in respect and other material reqd. Make as per brand List of HPHC

7

-

4250

... More
Supply and Erection of surface mounted LED batten 2 x 18 Watt, Polycarbonate housing & integrated electronic driver i/c cost of material & labour required to complete the job in all respect & making necessary connections. Make as per brand list of HPHC

4

-

1381

... More
S/E PVC pipe ISI Marked heavy guage i/c bend inspection box etc., i/c laying of pipe in slab or wall complete with all patty material required to complete the job in all respect .i) 25mm dia on recessed

800

-

45

... More
S/E of double door sheet steel enclosure distribution suitable for MCCB as incomer. recessed in wall i/c board with all labour and material required to complete the job in all respect upto to the entire satisfaction of the EIC of the work i) 8 way TPN (vertical ,MCCB provision for 100 amp -125 amp MCCB 4 P and provision for24 Nos.6 A-30 amp MCB SP as outgoings)

2

-

8940

... More
Supply and erection of Post-Top Lantern luminaire, decorative with UV stabilized polycarbonate diffuser suitable for 1x18 retrofit LED complete with 18 watt LED threaded type, fixed on existing pole. The work will be complete in all respect including making necessary connections, nuts & bolts and labour etc.

3

-

3162

... More
S/E of water cooler of stainless steel body with 150 ltr /hr cooling & 150 ltr storage capacity . ( USHA /SIDWAL/Voltas/bluestar -Make) & water purifier 40 ltr /hr. Capacity ( kENT -Make ) complete with all labour & petty material required to complete the job. Make as per brand list of HPHC

1

-

91900

... More
S/Eof fresh air fans (Exhaust fan) 250mm sweep PVC body with louver shutter, suitable for single phase A.C. 230 Volts, 50 HZ supply complete with all labour and petty material required to complete the job. ( Havell's - Make & Model - Ventlair DX or crompton Greaves model Brisk air)

7

-

1490

... More
Supply and erection of metal exhaust fan, double ball bearing suitable for single phase A.C. 230 Volts, 50 HZ capacitor ,900 RPM (Heavy duty) complete with mounting ring, blade, fixing and making necessary connections etc. (Crompton greaves make equivalent to other approved brands) i) Size 380 mm sweep

1

-

2914

... More
Supply and erection of aluminium anodized louver shutter for exhaust fan (Thickness of frame 1.00 mm & blade thickness 0.80 mm) including all labour and other petty material required to complete the job. (Canon, National make) i) Size 380 mm sweep

1

-

475

... More
Supply and erection of TV socket / RJ-11 Telephone Jack single shutter one module, complete in all respect including making necessary connections and labour etc.

3

-

115

... More
Supply and erection of RJ-11 Telephone Jack double shutter one module, complete in all respect including making necessary connections and labour etc.

14

-

143

... More
Supply and erection of RJ-45 computer Jack for CAT-6 cable, one module, complete in all respect including making necessary connections and labour etc.

14

-

419

... More
Supply installation testing & comissioning of DVR 16 Channel HD HDCVI cp plus, 1.2 mp with allied items for connections (make CP plus,Hik vision,Bosch)

1

-

12102

... More
Supply installation testing & comissioning of Power Supply 12v 20A, DC with allied items for connections (make CP plus,Hik vision,Bosch)

11

-

2600

... More
Supply installation testing & comissioning of CCTV Camera Bullet 1.3 MP 3.6mm 24 IR with allied items for connections (make CP plus,Hik vision,Bosch)

11

-

2114

... More
Supply installation testing & comissioning of Disk 4 TB for exsisting DVR allied items for connections ( Make seagate,Toshiba,transcend)

2

-

11067

... More
Supply installation testing & comissioning of DC pin cable BNC pin

40

-

32

... More
Supply installation testing & comissioning of 2 core cable box power

1

-

1602

... More
S/I/T/C of EPABX system model SL 1000(NEC) equipped with four trunks & 8 extension and expendable upto 64 lines with 8 nos telephone set model P-tel PT 33, 1 no. Telephone set model P-tel PT 55, Stabalizer CVR 500 VA, Single prop wire & PVC Channel complete in all respect.

1

-

34995

... More
S/I/T/C of 1.5 TR high wall 'split type air conditioning unit " Hitachi make ,3 Star rating at 220 volts+_ 10%single phase ,50 cycle per second electric supply and consisting of condensing and indoor unit,LCD cordless remote,Ms stand for outdoor unit,copper refrigrant piping per circuit of suitable size upto 3Mtr length,stablizer 5 KVA wall mount of 100 up volts(copper wound )and first charge of refrigrant gas .The work should be completed inall respecti/c making repair of wall ,floor and roof in original shape caused by making holes and chases etc. Make as per brand list of HPHC

2

-

44700

... More
Supply & erection of A.C. Ceiling fans of aluminium alloy body double ball bearing , copper wound complete with 300 mm down rod, canopies, shackles, three nos. blades etc. suitable for operation on single phase A.C. 230 Volts, 50 HZ supply including making necessary connections with one year warranty and all petty material required to complete job in all respect. i)1200 mm sweep

9

-

1200

... More
i)1400 mm sweep

24

-

1290

... More
Supply, Installation, testing & commissioning of Full HD 43” Full HD Monitor including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having minimum technical specifications and above as under:- Resolution : 1920*1080 (FHD) with minimum 350 nits, RS 232 control port, Backlight : LED, Response time: 5ms, Input : VGA,HDMI, Audio , Output: Speaker * 1, Consumption : 58W, Industrial Level DID LCD Panel, Suitable for extensive 7*24 Hours Continuous Works, Built in Speaker , Certificate : CE,CB,FCC (SAMSUNG+B398/LG/ PANASONIC/ SONY) Make as per brand list of HPHC

2

-

42000

... More
S/E of 1400 VA Invertor ( Luminious / Microtek / Sukem make ) suitable for operation on single phase 230 volts, 50 HZ, AC supply with 2 nos 150 AH Exide tublur batteries having warranty of 2 years i/c cost of trolly for batteries complete with all labour and petty material required i/c making necessary connections upto entire staisfaction of Engineer-in-Charge of the work.

2

-

30475

... More
Total NS(Estate Electrical)

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.