Panchayati Raj Department Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Panchayati Raj Department - GoH Tender

Works
Building Construction
Eprocure
Opening Date7 Jan 2025
Closing Date28 Jan 2025
Tender Amount₹ 73,65,45,383 
Notes
Download

Costs

  • EMD

    ₹ 1,47,30,900
  • Document Cost

    ₹ 50,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and fixing Stainless Steel Fittings (Chrome Finished) to doors, window, cupboard etc. (Grade 304) with nuts and screws etc complete.(as per sample approved by Engineer-in-charge) S.S sliding bolt (250 mm long)

262

-

-

... More
Providing and fixing Stainless Steel Fittings (Chrome Finished) to doors, window, cupboard etc. (Grade 304) with nuts and screws etc complete.(as per sample approved by Engineer-in-charge) S.S REAR MAGNETIC DOOR STOPER.

262

-

-

... More
Providing and fixing Stainless Steel Fittings (Chrome Finished) to doors, window, cupboard etc. (Grade 304) with nuts and screws etc complete.(as per sample approved by Engineer-in-charge) 150 mm floor S.S front Door stoppers (Godrej or equivalent make) with rubber cushion screws etc to suit shutter thickness complete.

232

-

-

... More
Providing and Fixing 450 mm long, 32 mm thick H type Stainless steel door handle for frame less doors (Ozone make or equivalent)

12

-

-

... More
Providing and Fixing Patch lock for frameless doors (Ozone make or equivalent)

12

-

-

... More
Providing and fixing of 6 mm thick HPL (High Pressure Laminate) sheet cladding in horizontal or verticle direction on the building facade. The facade tiles shall be rigid and of adequate strength and shall satisfy all the performance parameters. The HPL sheet Cladding shall be fixed to an extruded aluminium support framework consisting of vertical aluminium tubular sections measuring 40x40mm spaced at maximum 1000mm c/c intervals, fixed to the wall using aluminium L-brackets spaced at maximum 1200mm distance vertically. (Aluminium frame will be payable separately)

739.01

-

-

... More
Supply of Wooden fire cum accoustic doors as per BS:476 Part- 20 and 22 and IS 3614 part-1 and part-2 for stability, integrity and thermal insulation. 03 Criteria Wooden door confirming to IS 277 with the following specification. Recommended 52mm thick fire door shall have doors tested at CBRI vide test report no. FR/0378 Dt: 22-06-2018 for maximum rating of 2hrs without acoustic properties, as there is no arrangement to measure the acoustic properties at CBRI, Roorkee. Any deviation in specification other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. 120 MIN. FIRE RATING WOODEN FIRE CUM ACCOUSTIC DOOR (30-32 db)

23.04

-

-

... More
Synthetic surface - 2.1 mm thick for Gymnasium Providing and fixing 100% pure polyvinyl chloride (PVC) wear layer combined with a pure PVC backing. Sanosol®, a fungistatic and bacteriostatic treatment shall be incorporated throughout the entire thickness. The wear surface shall be Triple-Action Protecsol®, UV cured, factory applied, and permanently bonded to the surface of the resilient Flooring. 1. Width of the roll . 4’11” (1.50m) 2. Total Thickness of the roll. 2.1 MM THICK 3. Weight 0.56 /sq.ft 4. Static Load Limit ASTM F970 modified (600 p.s.i. 5. Dynamic Load Limit (N) DIN V 18032-2 (April 2001) )1000 N 6. Excellent Chemical Resistance ASTM D543 7. Fungus Resistance ASTM G21 . Complete 8. Critical Radiant Flux ASTM E648 Class 1 9. Fire Rating ASTM/E648 )0.45 W/cm² Class 1 (Make Taraflex Gerflor / Tarkett / BSW)

86.26

-

-

... More
External Wall Finishes Providing and Applying permanent stone finish wall covering system made of pure quartz, inorganic pigments, pure acrylic emulsions, binder of 100% pure acrylic emulsion, broad spectrum fungicides to be sprayed to the surface by means of a customized spray gun with a coating thickness of 1.5-2.0mm over coated with a clear acrylic top coat in 2 coats, to be applied on a cured, smooth and level plaster base without keying covered with a two coat wall care putty as per manufactures application products, as per shade combination approved by Architects all complete inclusive of primer on the base, for all height, inclusive of scaffolding and creation of groves it approves. Approved manufactures 1. Bakelite hylam 2. Unitile 3. Any other approved by architects

288

-

-

... More
Providing and installing Inclined pre-stressed temporary soil anchors for diaphragm wall including cost of MS sleeve, insert plate, bracket plate, drilling, re-drilling removal and disposal of sludge if necessary, through over burden, in all types of soil except rock with either rotary/pneumatic percussion method / manual boring method, flushing the hole fabrication with high tensile wires/strands grouting fixed and free length with cement grout and non-shrinkage compound Cebex-100 including stressing of anchors etc. complete as per BS: 8081 and BSEN :1537 and as per specifications and design approved. (Anchor Strand Make: Usha Martin, TATA, DP wires or equivalent)

532

-

-

... More
Providing and Filling Construction and longitudinal joints (5mm wide x 65mm deep) in VDC/PQC (of specified grade) by groove cutting machine, providing and filling joints with Polysulphide Pour Grade sealent (Make SIKA) in the VDC (of specified grade) complete as per specifications and directions of Engineer-incharge. (Item of dowel bars/tie bars to be paid separately).

2475

-

-

... More
Providing, fixing, Testing and Commissioning of health faucet with 1 m PVC tube and swivel hook including all fittings complete

88

-

-

... More
Providing and fixing, Testing and Commissioning of CP brass two way bib cock including, necessary flange, cutting and making good he walls / floors wherever required complete.

88

-

-

... More
Supplying, Installation, Testing and Commissioning of Water cooler(Blue Star - Model No. - SDLX 100) made of pure Stainless steel body, without rusting , without corrosion. including externallly mounted thermostat to make it easy to set water temperature, wth extra large SS wate tray prevent spalashing and ensures fast drainage of water , aoto cut facilitie , over load compressor protection, electricl supply internal wiring etc. to complete the work.

12

-

-

... More
Providing, fixing, jointing and testing in position the following uPVC pipes conforming to IS 4985 of 6 kg/sq cm pressure rating including all fittings, solvent weld joints, testing complete for drainage system cut to required length to be laid under floor including covering all around with cement concrete and making good the same complete as required. For waste pipes 40mm OD (6 kg pressure)

335

-

-

... More
Providing, fixing, jointing and testing in position the following uPVC pipes conforming to IS 4985 of 6 kg/sqcm pressure rating including all fittings, solvent weld joints, testing complete for drainage system cut to required length to be laid under floor including covering all around with cement concrete and making good the same complete as required. For waste pipes 50mm OD (6 kg pressure)

15

-

-

... More
Providing, fixing, jointing and testing in position the following uPVC pipes conforming to IS 4985 of 6 kg/sqcm pressure rating including all fittings, solvent weld joints, testing complete for drainage system cut to required length to be laid under floor including covering all around with cement concrete and making good the same complete as required. For waste pipes 63mm OD (6 kg pressure)

50

-

-

... More
Providing and Fixing 110 x110 mm outlet uPVC `P` trap with 2-3 inlets required size ftting with seal 50 mm of self cleansing design floor/urinal trap without vent suspended with supporting clamp or in sunken portion including cutting and making good the walls and floors wherever required complete in all respects.

122

-

-

... More
Providing and Fixing 110 x63mm outlet uPVC floor drain of following size inlet and outlet including cutting and making good the walls and floors wherever required complete in all respects.

30

-

-

... More
Providing and fixing PVC inlet fitting with one or more inlets fabricated from 110 mm outer dia UPVC pipe and solvent welded sockets and fixed to UPVC Trap and set in cement concrete as per drawing complete

122

-

-

... More
Providing and fixing SS grating of approved quality and colour. Circular type 124 mm nominal dia with 25 mm waste hole.

152

-

-

... More
Providing and Fixing GI pipes Confirming to IS Code - 1239, Class - `C`, complete with GI fittings and clamps, including cutting and making good walls etc. (internal work). 65 mm dia

165

-

-

... More
Providing and Fixing GI pipes Cofirming to IS Code - 1239, Class - `C`, complete with GI fittings and clamps, including cutting and making good walls etc. (internal work). 80 mm dia (Water Supply plus Sump Riser)

120

-

-

... More
Providing and Fixing GI pipes Cofirming to IS Code - 1239, Class - `C`, complete with GI fittings and clamps, including cutting and making good walls etc. (internal work). 100 mm dia

55

-

-

... More
Painting GI pipes and fittings with enamel paint over a ready mixed priming coat, both of approved quality for new work. 65 mm dia nominal bore

165

-

-

... More
Painting GI pipes and fittings with enamel paint over a ready mixed priming coat, both of approved quality for new work. 80 mm dia nominal bore (Water Supply plus Sump Riser)

120

-

-

... More
Painting GI pipes and fittings with enamel paint over a ready mixed priming coat, both of approved quality for new work. 100 mm dia nominal bore

55

-

-

... More
Providing and fixing 15 mm dia forged brass auto air vent valve 10 PN rating including all fitting and accessories.

2

-

-

... More
Providing and fixing 15 mm gun metal gate valve with C.I. wheel of approved quality (screwed end) :

10

-

-

... More
Supplying, Installation, Testing and Commissioning of 100 mm wafer end type cast iron butterfly valves conforming to IS : 13095 and BS : 5155 tested to 16 kg/sq.cm pressure (including flanges) .

2

-

-

... More
Supplying, Installation, Testing and Commissioning of 40 mm dia float valve (brass) with copper float of approved quality suitable for high or low pressure complete in all respects.

2

-

-

... More
Supply, Installation, Testing and Commissioning vitreous matrix set including matrix EWC (European type water closet) with cistern, wall hung matrix wash basin, lever arm faucet for ease of operation, centre pre-punched tap hole, grab bar with slightly lower height for added convenience and fixed to wall with brackets including cutting and making good the wall and floors as required. Colour Star White. (For Divyang Toilet)

6

-

-

... More
Providing and laying 300 mm diameter S.W. pipe cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:

230

-

-

... More
Providing and fixing 160 mm OD uPVC STP over flow pipe (I.S:4985) of 10 Kg/cm2 including all fittings e.g bends, junctions, elbow,f-tee,m-tee, offsets, access pieces etc. jointing with solvent cement including cutting holes in walls, excavating trenches of required width for pipes, excavation, refilling and disposal of surplus earth wherever required and making good.

250

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 300 mm diameter S.W. pipe

245

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 500 mm diameter S.W. pipe

20

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 400 mm diameter S.W. pipe

190

-

-

... More
800x800 Heavy Duty SFRC cover - Providing and fixing square recessed of size 800x800mm heavy duty SFRC manhole cover , double seal, water tight SFRC manhole cover and frame specially casted for placing over the re-charge pit and De-Silt Chember with lifting and locking arrangements as per approved sample, complete in all respect including fixing in rcc as per site requirement.

16

-

-

... More
400 mm Dia Boring - Drilling percolation Bore Hole of 400 mm dia with minimum upto 2 m above under ground aquifer, with reverse rotary method in all types of soil including costs for mobilisation of Rig, including development of bore with 300-400 cfm compressor and making good the area after completion of work. Contractor shall arrange for all necessary tools,consumables and water required for drilling and providing and fixing 2 nos. 260 mm OD UPVC perforated/partially plain pipe (6 Kg/cm.sq.) in bore hole with cap at top of approved brand and all complete as per the design and drawing approved for the construction.

400

-

-

... More
Providing and Fixing 110 mm (outer dia) PVC PIPE (10 KG) for vent of RWH pit with insect / mosquito proof.

400

-

-

... More
Providing and Fixing Grating of size 1200 mm x 750 mm made out with Frame of MS Angle 40*40* 5 mm and 16 mm Sq. bars @ 20 mm. clear spacing, which is to be fixed at the mouth of pipe insdie De-Silt Chember.

4

-

-

... More
SITC of 18W LED Surface/recessed type/ mounted round/square type downlighter. The Fixture should be Made of Extruded Aluminium Housing. Inbuilt Protection of 2kv, PF).95, System Wattage 18W integral housing for driver. Minium 100 lumens/W in 5700k.

542

-

-

... More
SITC of LED Surface/recessed type Mounted Square/Rect. Bulkhead Light. The Fixture should be Made of PDC Housing.PF).95, System Wattage 10w with Minium 100 lumens/W in 5700k. The Fixture should be IP-65of Makes :-PHILIPS-/HAVELLS/WIPRO

250

-

-

... More
SITC Surface/recessed type Mounted Bracket/wall light . The Fixture should be Made of chromeandmetal Housing.PF).95, System Wattage Tronto E27,24Ww with Minium 1500 lumens in 5700k. The Fixture should be of Makes :-PHILIPS-/HAVELLS/WIPRO

10

-

-

... More
SITC 45W LED Street Light. The Fixture should be Made of pressure diecast housing with TOUGHNED GLASS diffuser and indivisual LEDs with secondary optics with IP 66 protection. PF).95, System Wattage LED 45W with Minium 1500 lumens in 5700k. The Fixture should be of Makes :-PHILIPS-/HAVELLS/WIPRO

45

-

-

... More
SITC 1x18W or 18/20W LED 1200mm Batten Light. The Endura Fixture is a Surface/recessed type and wall mounted LED batten with extruded aluminium housing and robust construction . PF).95, System Wattage LED 20W with Minium 1500 lumens in 5700k. The Fixture should be of Makes :-PHILIPS-/HAVELLS/WIPRO

400

-

-

... More
SITC 6W LED aesthetically brillient Surface/recessed type picture/mirror light. The Fixture comprises of aluminium with silver/gold finish . PF).95, System Wattage LED 6W with Minium 1500 lumens in 5700k of size 70x87x350mm. The Fixture should be of Makes :-PHILIPS-/HAVELLS/WIPRO

50

-

-

... More
Supply of Surface/recessed type/recessed type 32W Full window glarefree opal Diffuser LED Panel of size 600X600mm suitable for Surface/recessed type with MS Powder coated White Housing. Total system Lumen of 36W LED should be 4100 or above in Cool day Light(5600K to 6500K), Power factor)0.90, CRI (Ra) )80, THD (20% LED Lamp. Efficacy)140 Lm/W. Complete with all accessories as required with connections PHILIPS-/HAVELLS/WIPRO

750

-

-

... More
SITC 2x18W or 36/40W LED 1200mm Batten Light. The Endura Fixture is a Surface/recessed type and wall mounted LED batten with extruded aluminium housing and robust construction . PF).95, System Wattage LED 40W with Minium 1500 lumens in 5700k. The Fixture should be of Makes :-PHILIPS-/HAVELLS/WIPRO

20

-

-

... More
Supply, erection, testing and commissionoing of 10 KVA UPS system complete with battery bank (30/60 minutes backup) SMF battery 12 V 65 AH/12V100AH = 16 Nos. complete with all accessories including battery breaker, racks, links, cabling including all petty material required to complete the job upto entire satisfaction of the Engineer-in-charge. Make: FUJI,NUMARIC,SOCOMEC./3EM/BPE

4

-

-

... More
Supply, erection, testing and commissionoing of 20 KVA UPS system complete with battery bank (30/60 minutes backup) SMF battery 12 V 65 AH/12V100AH = 16 Nos. complete with all accessories including battery breaker, racks, links, cabling including all petty material required to complete the job upto entire satisfaction of the Engineer-in-charge. Make: FUJI,NUMARIC,SOCOMEC/3EM/BPE

1

-

-

... More
Supply of aluminium onductor PVC/XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988. Make Havells,Polycab,RR Overall size 16sq.mm (4Core) Armoured

840

-

-

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing Surface/recessed type/ recessed steel/ PVC conduit as required.(DSR 1.19 Based)

650

-

-

... More
24 Port POE Rack Mountable, Gigabit Switch with 4 SFP Port etc. as reqd. D-Link DGS-1210-28 P 10/100/1000Mbps Unmanaged Ethernet Switch with 1 year Warrenty (For Data points distribution)

18

-

-

... More
SITC of Metal/GI Raceways having 2.44 mtr standered length size 225x38x 3 compartments 1.6mm thick. Legrand code 6895-04

250

-

-

... More
SITC of Metal/GI Raceways having 2.44 mtr standered length size 100x38x 1 compartments 1.6mm thick. Legrand code 6895-02

250

-

-

... More
SITC of Metal/GI Raceways having 2.44 mtr standered length size 50x38x 1 compartments 1.6mm thick . Legrand code 6895-00

250

-

-

... More
SITC of Fixing brackets for 225x38mm 3 compartment 1.6mm thick raceways Legrand Code 6897-25

45

-

-

... More
SITC of Fixing brackets for 100x38mm 1 compartment 1.6mm thick raceways Legrand Code 6897-37

45

-

-

... More
SITC of Fixing bracket for 50x38mm 1 compartment 1.6mm thick raceways Legrand Code 6897-27

45

-

-

... More
SITC of Vertical Riser for 225mm width raceways Legrand Code-6897-23

100

-

-

... More
SITC of coupler for joining raceways Legrand Code- 6897-77

45

-

-

... More
SITC of Height Adjustable Junction Box with lid size 225x225x60-90mm Legrand Code 6896-11

50

-

-

... More
Wiring for 250 volts single phase and neutral 25 amps 3 pin industrial socket outlet with 25 amps DP interlocked rotary switch in polycarbonate enclosure of approved size and design with 6 sq. mm PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires in concealed or surface mounted 25 mm dia 16 gauge thick FRLS PVC conduit, including providing and fixing of 3 pin industrial socket and earthing of third pin of the socket outlet with 3 run 6 sq. mm PVC insulated copper conductor stranded flexible FRLS wire. CAR CHARGING PURPOSE

10

-

-

... More
Wiring for 250 volts Three phase and neutral 30 amps 5 pin industrial socket outlet with 32 amps 4P interlocked rotary switch in polycarbonate enclosure of approved size and design with 6 sq. mm PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires in concealed or surface mounted 32 mm dia 16 gauge thick FRLS PVC conduit, including providing and fixing of 4 pin industrial socket and earthing of third pin of the socket outlet with 6 run 6 sq. mm PVC insulated copper conductor stranded flexible FRLS wire.CAR CHARGING PURPOSE

5

-

-

... More
SITC of 6W Recessed Ceiling speakers with following features:-Speaker Drive 6`, Complete Aluminium grille and Metal baffle, line matching transformer 100/70V line. Variable wattage tappings of 6 / 3 / 1.5, Effective frequency range 110-15kHz (BS6840), SPL@1m/1W=91dB, Peak SPL 97dB complete with necessary mounting hardware and accesories. Make: Honeywell/BOSCH/JBL

350

-

-

... More
SITC of 6W Recessed Ceiling speakers with following features:-Speaker Drive 6`, Matching transformer 100V. Variable tapping 10W/5W, SPL@1M/1W - 90dB, Peak SPL 98dB. the cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge.

25

-

-

... More
Supply, Installation,Testing and Commissioning of Digital Voice Evacuation system for 8 Zones. The System shall meet the standards of BS EN54 - 32 and EN 60849. it should be capable for the EVAC, Paging, PA and BGM functions. The Controller shall have SD card option to store the EVAC and Alert Voice Message. The Controller shall have Speaker line supervision and amplifier auto changeover. The Controller shall have following features: Seperate Zone volume control at the front side of panel, Status indications on the Panel for EVAC,Fault ,AC,DC ,Fault,ALERT and Fireman mic, Zone capacity up to 96 Zones, 8 programmable Control Input and output, Fireman Microphone with High Priority, THD(1%, Frequency response 80Hz - 20kHz, Up to 1000 Record files, 100V Class-AB Speaker Output. Make: Honeywell/BOSCH/JBL

1

-

-

... More
SITC of Remote Paging microphone with minimum 08 buttons and Busy/Hole Indication. The Microphone Should be suitable for Desktop mounting. Make: Honeywell/BOSCH/JBL

1

-

-

... More
Supply Installation testing and comisioning of 500W RMS Dual Channel Power Amplifier with Switch power technology for power electricity saving, Separate PFC Design for highest reliability, Separate Power Supply System. Amplifier shall have Following Features: 240W RMS per Channel, Amplifier Output 100V, Supply input AC 220 plus /- 10% - 50/60Hz, Short Circuit, Power, Tempreature, Overload Protection, Auto Cooling Fans. THD (0.1%, Frequency Response 40Hz - 20kHz, AC and DC Fuse, SNR )89dB. Make: Honeywell/BOSCH/JBL

4

-

-

... More
Supply Installation testing and comisioning of Professional CD/DVD player with USB flash port and 19` Rack mount arrangement.

1

-

-

... More
Supply Installation testing and comisioning of 19-inch Equipment Rack with standardized frame or enclosure for mounting multiple PA controllers, CD player, Amplifiers etc modules. Size 24U.

1

-

-

... More
Supply and Laying of 1.5 sq.mm. multistrand PVC sheathed Two Core Twin Twisted Speaker Cable in Exiting PVC Conduit.

6500

-

-

... More
SITC of 10 Loop with Expendable Loops Micro processor based 1 wire fault tolerant loop, required loop networkable type (each loop accessing 199 detectors and 199 modules ) fire alarm/detection control panel having 640 Character Display The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character LCD unit to indicate Fire/Fault Signal with addresses. The Panel Shall be Sheet Steel Painted, sealed to IP30. The panel should have provision to integrate with PA System . The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. and conforming to BS5839 Standards and Duly Approved by EN54/UL. (EDWORD/Siemans/JOHNSON CONTROL)

1

-

-

... More
SITC of Analogue Addressable type Smoke Detector with Visible bi-color LEDs for 360 deg having Rotary, decimal addressing system in the range of 01-159, complete with standard base, as required, complying to EN54 and/UL approved (EDWORD/Siemans/JOHNSON CONTROL)

650

-

-

... More
SITC of Analogue Addressable type Heat Detector with Visible bi-color LEDs for 360 deg having Rotary, decimal addressing system in the range of 01-159, complete with standard base, as required, complying to EN54 and/UL approved (EDWORD/Siemans/JOHNSON CONTROL)

40

-

-

... More
SITC of fault isolator Module with termination preferably after every 20–30 devices and shall be able to isolate electrical short circuit in the wiring etc. as required and Duly Approved by EN54/UL (EDWORD/Siemans/JOHNSON CONTROL)

35

-

-

... More
SITC of Analog Addressable Type Manual Call Point having Surface or flush mounting Option fully complaint to EN54 having Rotary Decade Swicthes for Addressing from 01-99 complete with Back Box for Mounting Complete as required conforming to BS5839 Standards and Duly Approved by EN54/UL (EDWORD/Siemans/JOHNSON CONTROL)

30

-

-

... More
SITC of Sounder Cum Strobe complete with Mounting Base as required conforming to BS5839 Standards and Duly Approved by EN54/UL (EDWORD/Siemans/JOHNSON CONTROL)

30

-

-

... More
SITC of Output control module for Lift,Ahu,pressure fan/Exast fan etc.

6

-

-

... More
SITC of input monitor module for FA panel intigration with fire fighting flow switch.

40

-

-

... More
2Core 1.5 Sqmm Copper Aromerd Cable FRLS including the cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge.

8500

-

-

... More
SITC of Digital Hybrid IP-PBX System configured for 08 Analog Trunk Connectivity, 24 Digital Extensions, 140 Analog Extensions. It should be possible to reach the capacity of system to 240 ports and 999 IP users without any add-on CPU or chassis/hardware platform. System should have two Gigabit Ethernet ports for LAN and WAN to separate out local and VoIP traffic on external network.It should be suitable for DTMF as well as the FSK type of telephone instruments. It should have built-in multi-party conferencing without any software licensing. It should be possible to carry out 15 conferences of 3-participants at a time. The system shall have built-in web based software programming tool for system administration. The call ringing sequence would be programmable and have options such as simultaneous, hunting off, round robin and delayed simultaneous.The system shall support flexible numbering for extensions such as it may have extensions with 1 digit, 2 digits and up to 6 digits numbers as well as in combination of all.The system should have built-in outgoing Call Log buffer of 6000 calls, incoming call log buffer of 5000 and call log buffer of 1000 internal calls. Operator features shall have the assistance to extension, attended call transfer, call intercept, indication of call waiting, night service control etc. should be available by default. Make Panasonic/Philips/ NEC / AVAYA / CISCO/ SEIMENS/Matrix

1

-

-

... More
Sutable Key Telephone set above exchange complete With Patch cords

20

-

-

... More
Sutable Basic phone set above exchange complete With Patch cords

50

-

-

... More
S/I/T/C of MDF Box for telephone distribution system complete with necessary connections in all respect.-20 Pair

2

-

-

... More
S/I/T/C of MDF Box for telephone distribution system complete with necessary connections in all respect.-50 Pair

5

-

-

... More
S/I/T/C of MDF Box for telephone distribution system complete with necessary connections in all respect.-100 Pair

1

-

-

... More
400 KVA DG Supply, transporting, loading, unloading, erecting, testing and commissionig etc. of Silent Type Diesel Generating Set of 400 KVA, 3 phase and neutral, 50 c/s. 415 A.C. rating, comprising of following Diesel Engine, Alternator, Sound Attenuated Acoustic Enclosure, including necessary RCC foundation for errection including earth work as required and with other associated accessories: As per latest Norms for CPCB-IV rating Diesel Engine Diesel engine 4 stroke Water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50%RH and at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour included in 12 hours of continuous operation. The engine will be fitted complete with all the required accessories Engine mounted Instrument Panel fitted with and having digital display for following: Start-Stop switch with push button Water temperature indication Lubrication Oil pressure indication Battery charging indication RPM indication Over speed indication Engine Hours indication Digital electronic governor/digital voltage regulator Battery monitoring system and weak battery warning Digital metering for current, voltage, PF, KWH, KVA Alternator protection for under/over voltage, under/over frequency, reverse power, over current. Alternator: Alternator rated at 400 KVA, 415 volts at 1500 RPM, 3 phase 50 HZ, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH and at 100 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty self excited and self-regulated through AVR conforming to IS :4722/BS 2613 suitable for tropical condition and ambient temperature at 50 Degree C and as per manufacturer`s standard specifications with class-H insulation. Auto Start/Auto load management should be through controller type 3300 or approved equipment. with suitable Breaker Base Frame and Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary PCC block of 1:1.5:3 ratio of cement concrete of depth of 300 mm with suitable reinforcement which shall be installed on existing hard concrete floor and vibration isolation arrangement as per recommendation of manufacturer. Exhaust System: Dry exhaust manifold of suitable dia, welded blank MS pipe confirming to IS:3589 cut to required lengths (max. 2 mtrs) and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with 50mm thick mineral wool/Rockwool, wire mesh and aluminium cladding 0.8 mm thick etc. as required as per specifications with hospital exhaust silencer. Starting System: 24V DC Starting system comprising of starter motors: Voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (2 Nos. of 180 Amp. Hour capacity maintenance free ) as required as per specifications. Fuel Tank: Daily service fuel tank of 990 liters capacity fabricated out of 3 mm thick MS sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS Class C pipe of suitable dia complete with valves, level indication, flow switch with potential free contacts for giving signal to existing BMS system and accessories as required as per specifications.

2

-

-

... More
Exhaust Piping Work : `Design, manufacture, supply, erection, testing and commissioning of B Class DG exhaust piping of following size suitable for above mention DG sets including Anti vibration mounting arrangement ,Structural load support, Steel bracket including foundation ,foundation bolts to avoid any load and stress on turbo charger/exhaust pipe , supports for maintenance . This structure shall be designed as per prevaling indian standard for earthquake , wind velocity, gravity loads,temperature loads at site. Item Include welding, cutting and fixing of require acessories , 2 layers of anti-coating primer with 2 layers of silver paint etc whereever require .exhauts piping work include the insulation of silencer and exhaust pipe with rain trap to avoid rain water entry in pipe and inspection spout at suitable location.The grade of pipe/class should be suitable to relevant latest applicable code in addition to technical specifcation and CPCB. These are the minimum requirements , work should be completed in line requirements of DG manufacturer recommendation as per site requirement ,Complete in all resepct as :- . ` Supply, erection, testing and commissioning of MS exhaust piping horizontal run as per IS 3589and 1239 of following sizes with welding joint including bends, MS pipe, clamps, dash fastener, nuts, bolts etc. with insulation by applying MAS-17 adhesive then a layer of minimum 75 mm thick rockwool (150Kg/Cub Mtr.) covered with 24 SWG aluminium sheet claddings etc. complete as required and as per specifications. 200 mm dia. NB (4.85mm Thickness)

15

-

-

... More
Design, manufacture, supply, erection, testing and commissioning of B Class DG exhaust piping of following size suitable for above mention DG sets including Anti vibration mounting arrangement ,Structural load support, Steel bracket including foundation ,foundation bolts to avoid any load and stress on turbo charger/exhaust pipe , supports for maintenance . This structure shall be designed as per prevaling indian standard for earthquake , wind velocity, gravity loads,temperature loads at site. Item Include welding, cutting and fixing of require acessories , 2 layers of anti-coating primer with 2 layers of silver paint etc whereever require .exhauts piping work include the insulation of silencer and exhaust pipe with rain trap to avoid rain water entry in pipe and inspection spout at suitable location.The grade of pipe/class should be suitable to relevant latest applicable code in addition to technical specifcation and CPCB. These are the minimum requirements , work should be completed in line requirements of DG manufacturer recommendation as per site requirement ,Complete in all resepct as :- .Supply, erection, testing and commissioning of MS exhaust piping vertical run as per IS 3589and 1239 of following sizes with welding joint including bends, MS pipe, clamps, dash fastener, nuts, bolts etc. with insulation by applying MAS-17 adhesive then first layer of insulation 25mm thick ceramic fibre wool (96Kg/Cub. Mtr.) and second layer minimum 100mm thick rockwool(150Kg/Cub Mtr.) covered with 24 SWG aluminium sheet claddings etc. complete as required and as per specifications. 200 mm dia. NB (4.85mm Thickness)

45

-

-

... More
Supply and Fixing of SS expansion joints for horizontal/ vertical exhaust pipes as required at site: 200 mm dia. NB (4.85mm Thickness).

4

-

-

... More
APPROVAL OF STATUTORY AUTHORITY: Preparation of drawings/documents in required sets to be submitted to statutory authority, obtaining approval/permission of electrical installation for operation of DG Sets as standby source, including Liasioning with Electrical Inspector/Local Supply Authority/Pollution Control Board etc. complete as required.

1

-

-

... More
HT SWITCHGEAR OUTDOOR TYPE 11kV 630Amps 20kA for 3 sec. and tested for 20kA/ 1 sec internal arc , SF6 insulated Non-Extensible Compact switchgear consisting of One No. Direct Module for Incomer and one No. of Fixed Manual Vacuum Circuit Breaker in SF6 insulated Stainless steel enclosure with series trip,self powered microprocessor based numerical over current and Earth Fault (IDMT plus Inst.) relay protection along with. Interconnection between HT switchgear and transformer shall be using 1Cx3x240 sq.mm Al. unarmorured XLPE Cable. NEAR METER ROOM

1

-

-

... More
CSS SYSTEM Supply of 11kV compact secondary substation suitable for Outdoor installation with natural cooling, having type tested equipments comprising of oil-type distribution transformer and SF-6 insulated compact switchgear enclosed in robotically sealed stainless steel tank, low-voltage switchboard, interconnection between HT switchgear and transformer using cables and transformer to LT-switchgear using aluminium busbars, factory built ready for connection type, internal GI earthing provided complete with other associated equipments etc. complete as required conforming to IEC 62271-202 and relevant IS or international specifications, as regards to design, manufacturing, type-testing, routine-testing and operator safety (IAC AFLR). The enclosure shall have modular construction using G.I. Sheet and shall be powder-coated from exterior. The Transformer compartment will have IP-23 ingress protection, whereas the HT/LT compartment will have IP-54 protection. (Makes: ACCORD,ABB,SIEMENS) The 11kV Outdoor Compact Sub-Station shall be consisting of following , HT SWITCHGEAR 11kV 630Amps 20kA for 3 sec. and tested for 20kA/ 1 sec internal arc , SF6 insulated Non-Extensible Compact switchgear consisting of One No. Direct Module for Incomer and one No. of Fixed Manual Vacuum Circuit Breaker in SF6 insulated Stainless steel enclosure with series trip,self powered microprocessor based numerical over current and Earth Fault (IDMT plus Inst.) relay protection along with. Interconnection between HT switchgear and transformer shall be using 1Cx3x240 sq.mm Al. unarmorured XLPE Cable. TRANSFORMER 1no. 800KVA 11KV/433V Dyn11 Oil (Ester Oil )filled hermatically sealed transformer without conservator type of design having corrugated tank and Top normal porcelein Bushings for HT and LT with ONTC and RTCC switch of rating plus 5% to -15% @2.5%. Temp Rise - Oil/Winding 40/50 deg cel, NL/FL Losses = 1.4/14 KW (Subject to IS-1180 Tol.), Impedanace 5% (Subject to IS Tol.) Oil temperature Indicator, Winding Temperature indicator with Alarm and Trip Contact LVS PANEL -1600AMPS ALUMINIUM BUSBARS INCOMER 1 Nos. 1600A, 50KA 4 pole microprocessor based EDO, ACB with integral protection OUTGOING Direct Cable termination Suitable for 6 nos 3.5 core 300 sqmm, 1100 V grade, XLPE insulated PVC sheathed Arnoured Aluminium cables APFC (Automatic Powerfactor control) 250 kVAR APFC with 50X2, 25X2, 15X2,10X2 KVAR MPP type capacitor with MCCB/MCB/contactor and 10 step RVC relay with 400 Amp. 3P MCCB for incomer to APFC. OUTDOOR ENCLOSURE Outdoor type enclosure with slanted roof and having construction of Galvanised Sheet Steel of thickness 1.5/2mm. The enclosure shall be type tested for IAC 20 kA/ 1 sec AB class as well as impact test as per IEC 62271-202 or international standards with reports not later than 5 years. The Enclosure shall have IP54 degree of protection for HT and LT switchgear compartment and IP23 degree of protection for Transformer compartment with transformer compartment thermal class of K-20 as per latest IEC. The enclosure shall be Powder Coated (Colour Light Gray and D.A.Gray ). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for each compartment. INTERCONNECTION AND EARTHING Interconnection Between HT switchgear and Transformer using 1Cx3x240Sq.mm XLPE Single core cable and Interconnection between Transformer and LT switchgear using Aluminium Busbars. Internal earthing connections by using 50x6 mm GI strips. Supply Rate for 11 kV Compact Substation as per specification and as described above

1

-

-

... More
LT PANEL Design, fabrication, assembly, wiring and supply of front operated dead front cubicle type compartmentalised as per Form 3B, rear access free standing, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for a symmetrical fault level of 50 kA at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below. (Note:The contractor may select the next higher fault rating of ACB/MCCB if it is not readily available ,without any extra cost ,as the figure indicated within the bracket are required maximum fault level of the panel). The rating of breakers may be changed at the time of detailed engineering as per project requirement without any extra cost implication to client). MAKE :application control/Allied Engineer/ADVANCE ALL LT PANEL, Panel’s shall be provided AS PER IEC-61439 Capacitor Panel’s shall be provided AS PER IEC-61921 With Gas Seprassion System MAIN LT Panel INCOMER FROM TRANSFORMER From 800 KVA Transformer - 1 1 No. 1600A 4 pole microprocessor based EDO, ACB (50kA) with integral protection as per PRMB-1 mentioned in Premable 1 set of 1600/5A, 15 VA, class-1 CTs for APFC relay 1 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-1600A) Ammeter with ASS with 3 nos.1600/5A CT`s 1No. Digital multifunction meter class 1.0 accuracy, with RS 485 port output for IBMS integration with read (V,A,F,PF, kW, kVA, kVAR, kWh, kVAh, kVARh) etc 1Set- of ON/OFF/Trip/ Spring Charged and Trip circuit healthy indicating lamps. 240 V AC Motor wound spring closing mechanism 1 - 24 volts DC shunt trip coil 6 nos NO/NC contacts for remote opening and closing Terminals to receive XLPE insulated Aluminium cables Class – B transient voltage surge suppression devices suitable for 3 phases as per specification. INCOMER FROM DG 2 Nos. 630A 4 pole microprocessor , EDO ACB (50kA) with integral protection as per PRMB-1 mentioned in Premable with reverse power relay. 1 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-630A) Ammeter with ASS with 3 nos. 630/5A CT`s 1No. Digital multifunction meter class 1.0 accuracy, with RS 485 port output for IBMS integration with read (V,A,F,PF, kW, kVA, kVAR, kWh, kVAh, kVARh) etc Terminals to receive XLPE insulated Aluminium cables Class – B transient voltage surge suppression devices suitable for 3 phases as per specification. BUS BARS 1 Nos Electrolytic high conductivity CU three phase and neutral busbars with earthing rated at 1250 amps having a maximum current density of 0.8 amp per sq mm suitable to with stand symmetrical fault level of 50 kA at 415 volts. The neutral busbar is to be of 50% capacity. BUS COUPLER-1:- 1 No. 630A 4 pole microprocessor based EDO ACB (50kA) , with all required accessories. OUTGOINGS 1 Nos. 1000A FP ACB (36 KA) as per PRMB-2 as mentioned in Preamble.with R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. and Multifunction meter with RS 485 port for IBMS integration and 3 nos.1000/5A CT`s . 2 Nos. 630A FP MCCB (36 KA) as per PRMB-2 as mentioned in Preamble.with R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. and Multifunction meter with RS 485 port for IBMS integration and 3 nos.630/5A CT`s . 1 No. 250A FP MCCB (36 KA) as per PRMB-2 as mentioned in Preamble.with R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. and Multifunction meter with RS 485 port for IBMS integration and 3 nos.250/5A CT`s . 2 Nos. 200A FP MCCB (36 KA) as per PRMB-2 as mentioned in Preamble.with R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. and Multifunction meter with RS 485 port for IBMS integration and 3 nos.200/5A CT`s . 1 No. 160A FP MCCB (36 KA) as per PRTM as mentioned in Preamble.with R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. and Multifunction meter with RS 485 port for IBMS integration and 3 nos.160/5A CT`s .(For Lift) 3 Nos. 125A FP MCCB (36 KA) as per PRTM as mentioned in Preamble.with R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. and Multifunction meter with RS 485 port for IBMS integration and 3 nos.125/5A CT`s . 3 Nos. 100A FP MCCB (36 KA) as per PRTM as mentioned in Preamble.with R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. and Multifunction meter with RS 485 port for IBMS integration and 3 nos.100/5A CT`s . AUTO ON/OFF AND AUTO LOAD MANAGEMENT : `Hardware using PLCs for Monitoring of all Electrical Software and for operations, controlling and interlocking Parameters of 1 No. DG Panel and 1 Nos. Transformer with Window based software and Engineering and Software Development. Required Aux. Relays, Push Buttons and Indication lamps, 1KVA UPS for Black start and maintenance free Batteries, Power monitors, Programmable Logic controller, Annunciator and status Fascia, MIMIC with LED circuit etc as required completing the system.(As per SLD). ` The Switchboard with Logic control panel shall be complete with all interconnections, risers, internal wiring, labels, control/circuit fuses etc. complete as required. Note: Incomer from LT Supply, DG Panel and Bus coupler shall be electrically and mechanically interlocked. Main LT Panel as described above

1

-

-

... More
LIFT PANEL 100A 4 pole Automatic changeover switch from main to Dg and vice versa. Incomer 100A, TPN MCCB 25KA - 1No. 1 No. Digital 96 sq. mm voltmeter with selector switch and 2A control MCB 1 No. Digital CT operated 96 sq. mm Ammeter with selector switch 1 Set of 3 Nos. of phase indication lamps LED type with 2A control MCB BUSBARS 125A, TPN Aluminium busbars, including making necessary connections OUTGOINGS 63A, 4P MCB 10KA with 63A 4P ELCB- 6Nos. 63A, 4P MCB 10 KA- 2No. Comon area panel as described as per above specifications grouted, installed and tested complete as required.

1

-

-

... More
HVAC PANEL Incomer 400A, TPN MCCB 25KA - 1No. 1 No. Digital 96 sq. mm voltmeter with selector switch and 2A control MCB 1 No. Digital CT operated 96 sq. mm Ammeter with selector switch 1 Set of 3 Nos. of phase indication lamps LED type with 2A control MCB BUSBARS 500A, TPN Aluminium busbars, including making necessary connections OUTGOINGS 63A, 4P MCB 10KA with 63A 4P ELCB- 8Nos. 63A, 4P MCB 10 KA- 2No. Comon area panel as described as per above specifications grouted, installed and tested complete as required.

1

-

-

... More
VENTILATION PANEL Incomer 125A, TPN MCCB 25KA - 1No. 1 No. Digital 96 sq. mm voltmeter with selector switch and 2A control MCB 1 No. Digital CT operated 96 sq. mm Ammeter with selector switch 1 Set of 3 Nos. of phase indication lamps LED type with 2A control MCB BUSBARS 150A, TPN Aluminium busbars, including making necessary connections OUTGOINGS 63A, 4P MCB 16KA with 63A 4P MCCB- 8Nos. 63A, 4P MCB 10 KA- 2No. Comon area panel as described as per above specifications grouted, installed and tested complete as required.

1

-

-

... More
Supply, installation, testing and commissioning of BMS Computer System: i7 Processor, latest generation or Equivalet Server PC, Intel(R) Xeon(R) Processor, 2.93GHz, 4MB Cache with 16 GB RAM, and 1 TB SSD, 10/100 Mbps Ethernet card, USB connection and internal modem, Microsoft(R) Windows(R) 10 OS Professional Enterprise or latest, Web server software, DVD-ROM Drive (with RAM), 100/1000 Mbps NIC for Network connection and anti virus software as per Tender Specifications. Accessories included 32 Inch LED Screen, Optical Mouse and Key Pad, Windows Licensed software compatible with the above BMS System configuration complete as required.

1

-

-

... More
Laserjet A4 Black and White printer

1

-

-

... More
Supply, installation, testing and commissioning of 24 Port Layer 2 switch, with SFP Module, rack mountable and other termination accessories (Like Pigtails / LIUs / Convertors / Patch Cord, Etc) complete as required.

3

-

-

... More
Supply, installation, testing and commissioning of High-quality CAPACTIVE touch 7.0`` panels for technical on-site operation of plants as well as room operation. The Touch Panel shall have integrated web server and a BACnet/ IP web interface to connect a HTML5 browser to a device on the network. Generic operation and monitoring of plant functions (alarms, schedulers, calendars, set point changes, display of actual values, etc.) Honeywell / Siemens)

1

-

-

... More
Supply, installation, testing and commissioning of True IP Based DDC Standalone 32 Bit Intelligent, inbuilt web browser, peer to peer communication, interoperable DDC as per the specification. The compact controller shall have inbuilt 2-port Ethernet switch, The controller shall have min 12 inputs/outputs inbuilt and can be expandable upto max 40 points by Input/Output Modules. The DDC shall have 300 Mhz processor with 128 MByte SDRAM (DDR3) and 512 MByte NAND Flash. The controller shall be freely programmable and have System functions (alarming, scheduling, trending, access protection with individually definable user profiles and categories). Honeywell / Siemens) The above shall be housed in vandal proof, lockable and secure MS Cabinets to be supplied along with all necessary switchgear protections as required. Number of controllers shall have spare capacity of 15% for future expansion Honeywell / Siemens). Controller for Common Area

1

-

-

... More
Supply, installation, testing and commissioning of True IP Based DDC Standalone 32 Bit Intelligent, inbuilt web browser, peer to peer communication, interoperable DDC as per the specification. The compact controller shall have inbuilt 2-port Ethernet switch, The controller shall have min 12 inputs/outputs inbuilt and can be expandable upto max 40 points by Input/Output Modules. The DDC shall have 300 Mhz processor with 128 MByte SDRAM (DDR3) and 512 MByte NAND Flash. The controller shall be freely programmable and have System functions (alarming, scheduling, trending, access protection with individually definable user profiles and categories). Honeywell / Siemens) The above shall be housed in vandal proof, lockable and secure MS Cabinets to be supplied along with all necessary switchgear protections as required. Number of controllers shall have spare capacity of 15% for future expansion Honeywell / Siemens). Controller for Ceiling Suspended AHU ( Max 5 Fans per DDC)

4

-

-

... More
Supply, installation, testing and commissioning of True IP Based DDC Standalone 32 Bit Intelligent, inbuilt web browser, peer to peer communication, interoperable DDC as per the specification. The compact controller shall have inbuilt 2-port Ethernet switch, The controller shall have min 12 inputs/outputs inbuilt and can be expandable upto max 40 points by Input/Output Modules. The DDC shall have 300 Mhz processor with 128 MByte SDRAM (DDR3) and 512 MByte NAND Flash. The controller shall be freely programmable and have System functions (alarming, scheduling, trending, access protection with individually definable user profiles and categories). Honeywell / Siemens) The above shall be housed in vandal proof, lockable and secure MS Cabinets to be supplied along with all necessary switchgear protections as required. Number of controllers shall have spare capacity of 15% for future expansion Honeywell / Siemens). Controller for Basement ventilation Fans ( Max 5 Fans per DDC)

8

-

-

... More
Supply, installation, testing and commissioning of True IP Based DDC Standalone 32 Bit Intelligent, inbuilt web browser, peer to peer communication, interoperable DDC as per the specification. The compact controller shall have inbuilt 2-port Ethernet switch, The controller shall have min 12 inputs/outputs inbuilt and can be expandable upto max 40 points by Input/Output Modules. The DDC shall have 300 Mhz processor with 128 MByte SDRAM (DDR3) and 512 MByte NAND Flash. The controller shall be freely programmable and have System functions (alarming, scheduling, trending, access protection with individually definable user profiles and categories). Honeywell / Siemens) The above shall be housed in vandal proof, lockable and secure MS Cabinets to be supplied along with all necessary switchgear protections as required. Number of controllers shall have spare capacity of 15% for future expansion Honeywell / Siemens). Controller for Smoke and Exhaust Fans (Max 4 Fans per DDC)

13

-

-

... More
Supply, installation, testing and commissioning of True IP Based DDC Standalone 32 Bit Intelligent, inbuilt web browser, peer to peer communication, interoperable DDC as per the specification. The compact controller shall have inbuilt 2-port Ethernet switch, The controller shall have min 12 inputs/outputs inbuilt and can be expandable upto max 40 points by Input/Output Modules. The DDC shall have 300 Mhz processor with 128 MByte SDRAM (DDR3) and 512 MByte NAND Flash. The controller shall be freely programmable and have System functions (alarming, scheduling, trending, access protection with individually definable user profiles and categories). Honeywell / Siemens) The above shall be housed in vandal proof, lockable and secure MS Cabinets to be supplied along with all necessary switchgear protections as required. Number of controllers shall have spare capacity of 15% for future expansion Honeywell / Siemens). Controller for Electrical System LT/HT/Transformer/DG

1

-

-

... More
Supply, installation, testing and commissioning of True IP Based BTL and UL Listed for third party integration. The controller shall have 2-port Ethernet switch, WLAN interface and Cloud Connectivity. It should have BTL label (BACnet communications passed the BTL test) and consisting of Dual microprocessor with Storage capacity of 1 GByte RAM. It should support Real Time clock upto 7 Days. It should Support of the major communication protocols: BACnet/IP, BACnet MS/TP, Modbus IP and Modbus RTU upto 500 points. (Note - Integrator shall be of same DDC make only.) Honeywell / Siemens) Integration of VRV System on BACnet/IP Integration of AHU VFD on Modbus over RS485 Integration of UPS on Modbus over RS485 Integration of DG Sets on Modbus over RS485 Integration of HT Power Meter on Modbus over RS485 Integration of Energy Meters on Modbus over RS485 Integration of Lifts on Modbus over RS485 Integration of Hydroneumatuic Pumps VFDs on Modbus over RS485 Integration of FAS System on BACnet/IP

1

-

-

... More
Outside Temperature and RH Sensor along with IP65 radiation shield for outdoor protection Measuring Accuracy at At 15…35 °C 0…100 % r.h.: ±2 % r.h

1

-

-

... More
IBMS Field Instriment -PM 10 and PM 2.5 Sensor on Modbus

4

-

-

... More
IBMS Field Instriment -DP Switch Air

16

-

-

... More
IBMS Field Instriment -Duct Temperature Sensor Measuring Accuracy At -50…80 °C: ±0.7 K with Proble Length 400 mm

8

-

-

... More
IBMS Field Instrument - Duct Static Pressure Sensor Measuring Range 0…200 Pa, 0…250 Pa, 0…500 Pa with DC 0...10 V output

8

-

-

... More
IBMS Field Instrument - Current Relay

26

-

-

... More
IBMS Field Instrument - Flameproof Level Switch

2

-

-

... More
IBMS Field Instrument - Voltage Transducer

2

-

-

... More
IBMS Field Instrument - CO Sensor

13

-

-

... More
IBMS Field Instrument -Water pressure sensor

1

-

-

... More
IBMS Field Instrument - Bi Level Switch

4

-

-

... More
IBMS Cabling nd conduiting- Supply and laying of 2 Core 1.0 Sqmm Annealed Tinned Copper, Twisted pair, Shielded unarmoured cable for signal and power as per specifications

10200

-

-

... More
IBMS Cabling and conduiting - Supply and laying of 4 Core 1.0 Sqmm Annealed Tinned Copper, Twisted pair, Shielded unarmoured cable for signal and power as per specifications

3500

-

-

... More
IBMS Cabling and conduiting - Supply and laying of Cat-6 unarmoured cable with required jacks and points

3000

-

-

... More
IBMS Cabling and conduiting - Supply and laying of GI Flexible 25 mm

1200

-

-

... More
HVAC-`SITC of Complete VRV/VRV/VRF system with Comprising of Indoor and Outdoor units complete with insulated copper refrigerant piping, cabling electrical switchgear, drain piping, testing and CFC free gas charging .Scroll compressors shall be hermetically sealed Inverter driven type, with electronic controls capable of loading and unloading approx. between 10% capacity to 100% capacity of the unit, condenser coils with anti corrosive blue fins, axial flow fans, microprocessor based controller, etc. shall be fully weather proof , factory assembled and prewired with all accessories and electronics and refrigerant controls housed in a powdercoated MS sheet metal housing of the following actual capacity Outdoor units shall be capable to operate at Ambient Condition.The Units Shall be capable to provide cooling/Heating as per requirement. The Units Should be as per detailed technical specification and drawings. Note: HVAC Contractor is advised to verify the proposed ODU capacity (as mentioned below and in the equipment schedule attached in the tender)as per Ambient Condition specified above and consider the deration of piping length as required .Any increase or decrease in the capacity of ODUs should be done at the time of Tendering i.e.before finalization of order .Vendor should submit their Engineering guidelines as a supporting documents for the same.The bidder shall furnish de-areation values of VRF Outdoors at 43 Deg celcius mandatorily.(Please provide heat load sheet and approved by consultants before precurments of material.)MAKE-BLUESTAR/CARRIER/DAIKIN` `Outdoor units shall have cooling and heating mode, consisting of one/multiple modules with digital vapour injection/inverter scroll technology based compressor and environment friendly refrigerant R-410A only. The unit should have COP as per ASHRAE 90.1 (Latest standard) . The C.O.P confirmation should be from the O.E.M letter, for the following capacities.The cost shall include the cost of Cabling from MCB/ELCB/isolator to the outdoor unit. (Cable Length to be as per drawing).Isolator cost shall also include.The unit shall be provided with its own microprocessor control panel with provision for integration with the building management system for Air-conditioning system.The units shall be suitable for 415V±10%,50 Hz. supply and complete with electrical controls and panels. Cost of Cowl with Birdscreen (If Required) for Top Discharge outdoor unit shall also include ,requirement of cowl to be verified by the HVAC Vendor as per drawing /site conditions andcost of MS stand for ODUs should also considered. External vibration pad shall also be provided during installation. Below Outdoor units are Top Discharge,However HVAC Vendor is suggeted to verify their performance. Anti-Corrosive treatment on the complete refrigerant piping and on the Outdoor units fins should be provided. ` Outdoor Units- Ground Floors- All areas-80 HP

1

-

-

... More
`Outdoor units shall have cooling and heating mode, consisting of one/multiple modules with digital vapour injection/inverter scroll technology based compressor and environment friendly refrigerant R-410A only. The unit should have COP as per ASHRAE 90.1 (Latest standard) . The C.O.P confirmation should be from the O.E.M letter, for the following capacities.The cost shall include the cost of Cabling from MCB/ELCB/isolator to the outdoor unit. (Cable Length to be as per drawing).Isolator cost shall also include.The unit shall be provided with its own microprocessor control panel with provision for integration with the building management system for Air-conditioning system.The units shall be suitable for 415V±10%,50 Hz. supply and complete with electrical controls and panels. Cost of Cowl with Birdscreen (If Required) for Top Discharge outdoor unit shall also include ,requirement of cowl to be verified by the HVAC Vendor as per drawing /site conditions andcost of MS stand for ODUs should also considered. External vibration pad shall also be provided during installation. Below Outdoor units are Top Discharge,However HVAC Vendor is suggeted to verify their performance. Anti-Corrosive treatment on the complete refrigerant piping and on the Outdoor units fins should be provided. First Floor- All areas- 46 HP

1

-

-

... More
Outdoor units shall have cooling and heating mode, consisting of one/multiple modules with digital vapour injection/inverter scroll technology based compressor and environment friendly refrigerant R-410A only. The unit should have COP as per ASHRAE 90.1 (Latest standard) . The C.O.P confirmation should be from the O.E.M letter, for the following capacities.The cost shall include the cost of Cabling from MCB/ELCB/isolator to the outdoor unit. (Cable Length to be as per drawing).Isolator cost shall also include.The unit shall be provided with its own microprocessor control panel with provision for integration with the building management system for Air-conditioning system.The units shall be suitable for 415V±10%,50 Hz. supply and complete with electrical controls and panels. Cost of Cowl with Birdscreen (If Required) for Top Discharge outdoor unit shall also include ,requirement of cowl to be verified by the HVAC Vendor as per drawing /site conditions andcost of MS stand for ODUs should also considered. External vibration pad shall also be provided during installation. Below Outdoor units are Top Discharge,However HVAC Vendor is suggeted to verify their performance. Anti-Corrosive treatment on the complete refrigerant piping and on the Outdoor units fins should be provided. Second Floor- All areas- 84 HP

1

-

-

... More
Outdoor units shall have cooling and heating mode, consisting of one/multiple modules with digital vapour injection/inverter scroll technology based compressor and environment friendly refrigerant R-410A only. The unit should have COP as per ASHRAE 90.1 (Latest standard) . The C.O.P confirmation should be from the O.E.M letter, for the following capacities.The cost shall include the cost of Cabling from MCB/ELCB/isolator to the outdoor unit. (Cable Length to be as per drawing).Isolator cost shall also include.The unit shall be provided with its own microprocessor control panel with provision for integration with the building management system for Air-conditioning system.The units shall be suitable for 415V±10%,50 Hz. supply and complete with electrical controls and panels. Cost of Cowl with Birdscreen (If Required) for Top Discharge outdoor unit shall also include ,requirement of cowl to be verified by the HVAC Vendor as per drawing /site conditions andcost of MS stand for ODUs should also considered. External vibration pad shall also be provided during installation. Below Outdoor units are Top Discharge,However HVAC Vendor is suggeted to verify their performance. Anti-Corrosive treatment on the complete refrigerant piping and on the Outdoor units fins should be provided. Third Floor- All areas- 50 HP

2

-

-

... More
Outdoor units shall have cooling and heating mode, consisting of one/multiple modules with digital vapour injection/inverter scroll technology based compressor and environment friendly refrigerant R-410A only. The unit should have COP as per ASHRAE 90.1 (Latest standard) . The C.O.P confirmation should be from the O.E.M letter, for the following capacities.The cost shall include the cost of Cabling from MCB/ELCB/isolator to the outdoor unit. (Cable Length to be as per drawing).Isolator cost shall also include.The unit shall be provided with its own microprocessor control panel with provision for integration with the building management system for Air-conditioning system.The units shall be suitable for 415V±10%,50 Hz. supply and complete with electrical controls and panels. Cost of Cowl with Birdscreen (If Required) for Top Discharge outdoor unit shall also include ,requirement of cowl to be verified by the HVAC Vendor as per drawing /site conditions andcost of MS stand for ODUs should also considered. External vibration pad shall also be provided during installation. Below Outdoor units are Top Discharge,However HVAC Vendor is suggeted to verify their performance. Anti-Corrosive treatment on the complete refrigerant piping and on the Outdoor units fins should be provided. Fourth Floor- All areas- 60 HP

1

-

-

... More
VRV/VRF TYPE OUTDOOR TFA UNITS: (Tailor made TFA units and shall be procured from other vendors duly approved by the manufacturer of the VRV units) Double skin Treated Fresh Air unit with VRV Compatible DX cooling coil. Supply, installation, testing and commissioning of double skin construction Horizontal/Vertical floor/Floor mounted(as per approved shop drawing and specifications) draw/blow through type DX TFA units fabricated out of extruded aluminium section with 0.6 mm pre-plasticized / pre-coated Galvanised steel sheet outside and 0.6 mm plain galvanised steel sheet inside: each complete (Wherever specified) low leakage aluminium aerofoil gear driven VCD and fire resistant neoprene flexible connection at outlet, pre-filter section with filters of non woven synthetic media (efficiency 90% down to 10 microns MERV-8) , coil section having min 8 Row Deep DX type coil of copper tube and aluminium fins construction alongwith distributor of suitable size. Coil shall have copper header and supporting frame work/End plates in SS 304 construction polished SS 304 drain pan made out of 22G sheet duly insulated complete with squirrel cage induction VFD Compatible motor, belt driven centrifugal backward curved fan or direct driven plug fan with vibration isolators. Coil size shall be selected for a maximum face velocity of 450 feet/minute and fan outlet velocity shall be limited to 1800 FPM. Motor shall be atleast IE 2 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply, meeting criterion as per ASHRAE standard 90.1-2010 and high efficiency. The AHU panels shall be insulated with minimum 40 mm thick and 40± 2 Kg/m³ density PU foam and shall have thermal break. The motor and blower assembly shall be mounted on aluminium extruded section only.Total static pressure shall be checked by vendor,change in static pressure will not attract any price implication.Fan capacities shall be based on minimum 20 mm external static pressure as mentioned below .The TFA shall be complete in all respects along with accessories as per specifications. The capacity of air handling units shall be as follows:MAKE-BLUESTAR/CARRIER/DAIKIN Outdoor Rating HP - 12

2

-

-

... More
VRV/VRF TYPE OUTDOOR TFA UNITS: (Tailor made TFA units and shall be procured from other vendors duly approved by the manufacturer of the VRV units) Double skin Treated Fresh Air unit with VRV Compatible DX cooling coil. Supply, installation, testing and commissioning of double skin construction Horizontal/Vertical floor/Floor mounted(as per approved shop drawing and specifications) draw/blow through type DX TFA units fabricated out of extruded aluminium section with 0.6 mm pre-plasticized / pre-coated Galvanised steel sheet outside and 0.6 mm plain galvanised steel sheet inside: each complete (Wherever specified) low leakage aluminium aerofoil gear driven VCD and fire resistant neoprene flexible connection at outlet, pre-filter section with filters of non woven synthetic media (efficiency 90% down to 10 microns MERV-8) , coil section having min 8 Row Deep DX type coil of copper tube and aluminium fins construction alongwith distributor of suitable size. Coil shall have copper header and supporting frame work/End plates in SS 304 construction polished SS 304 drain pan made out of 22G sheet duly insulated complete with squirrel cage induction VFD Compatible motor, belt driven centrifugal backward curved fan or direct driven plug fan with vibration isolators. Coil size shall be selected for a maximum face velocity of 450 feet/minute and fan outlet velocity shall be limited to 1800 FPM. Motor shall be atleast IE 2 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply, meeting criterion as per ASHRAE standard 90.1-2010 and high efficiency. The AHU panels shall be insulated with minimum 40 mm thick and 40± 2 Kg/m³ density PU foam and shall have thermal break. The motor and blower assembly shall be mounted on aluminium extruded section only.Total static pressure shall be checked by vendor,change in static pressure will not attract any price implication.Fan capacities shall be based on minimum 20 mm external static pressure as mentioned below .The TFA shall be complete in all respects along with accessories as per specifications. The capacity of air handling units shall be as follows:MAKE-BLUESTAR/CARRIER/DAIKIN ODU - (for TFA of fresh air supply ) HP-6

3

-

-

... More
VRV/VRF TYPE OUTDOOR TFA UNITS: (Tailor made TFA units and shall be procured from other vendors duly approved by the manufacturer of the VRV units) Double skin Treated Fresh Air unit with VRV Compatible DX cooling coil. Supply, installation, testing and commissioning of double skin construction Horizontal/Vertical floor/Floor mounted(as per approved shop drawing and specifications) draw/blow through type DX TFA units fabricated out of extruded aluminium section with 0.6 mm pre-plasticized / pre-coated Galvanised steel sheet outside and 0.6 mm plain galvanised steel sheet inside: each complete (Wherever specified) low leakage aluminium aerofoil gear driven VCD and fire resistant neoprene flexible connection at outlet, pre-filter section with filters of non woven synthetic media (efficiency 90% down to 10 microns MERV-8) , coil section having min 8 Row Deep DX type coil of copper tube and aluminium fins construction alongwith distributor of suitable size. Coil shall have copper header and supporting frame work/End plates in SS 304 construction polished SS 304 drain pan made out of 22G sheet duly insulated complete with squirrel cage induction VFD Compatible motor, belt driven centrifugal backward curved fan or direct driven plug fan with vibration isolators. Coil size shall be selected for a maximum face velocity of 450 feet/minute and fan outlet velocity shall be limited to 1800 FPM. Motor shall be atleast IE 2 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply, meeting criterion as per ASHRAE standard 90.1-2010 and high efficiency. The AHU panels shall be insulated with minimum 40 mm thick and 40± 2 Kg/m³ density PU foam and shall have thermal break. The motor and blower assembly shall be mounted on aluminium extruded section only.Total static pressure shall be checked by vendor,change in static pressure will not attract any price implication.Fan capacities shall be based on minimum 20 mm external static pressure as mentioned below .The TFA shall be complete in all respects along with accessories as per specifications. The capacity of air handling units shall be as follows:MAKE-BLUESTAR/CARRIER/DAIKIN Outdoor unit HP- 8

2

-

-

... More
VRV/VRF TYPE OUTDOOR TFA UNITS: (Tailor made TFA units and shall be procured from other vendors duly approved by the manufacturer of the VRV units) Double skin Treated Fresh Air unit with VRV Compatible DX cooling coil. Supply, installation, testing and commissioning of double skin construction Horizontal/Vertical floor/Floor mounted(as per approved shop drawing and specifications) draw/blow through type DX TFA units fabricated out of extruded aluminium section with 0.6 mm pre-plasticized / pre-coated Galvanised steel sheet outside and 0.6 mm plain galvanised steel sheet inside: each complete (Wherever specified) low leakage aluminium aerofoil gear driven VCD and fire resistant neoprene flexible connection at outlet, pre-filter section with filters of non woven synthetic media (efficiency 90% down to 10 microns MERV-8) , coil section having min 8 Row Deep DX type coil of copper tube and aluminium fins construction alongwith distributor of suitable size. Coil shall have copper header and supporting frame work/End plates in SS 304 construction polished SS 304 drain pan made out of 22G sheet duly insulated complete with squirrel cage induction VFD Compatible motor, belt driven centrifugal backward curved fan or direct driven plug fan with vibration isolators. Coil size shall be selected for a maximum face velocity of 450 feet/minute and fan outlet velocity shall be limited to 1800 FPM. Motor shall be atleast IE 2 rated suitable for 415±10% volts, 50 cycles, 3 phase AC supply, meeting criterion as per ASHRAE standard 90.1-2010 and high efficiency. The AHU panels shall be insulated with minimum 40 mm thick and 40± 2 Kg/m³ density PU foam and shall have thermal break. The motor and blower assembly shall be mounted on aluminium extruded section only.Total static pressure shall be checked by vendor,change in static pressure will not attract any price implication.Fan capacities shall be based on minimum 20 mm external static pressure as mentioned below .The TFA shall be complete in all respects along with accessories as per specifications. The capacity of air handling units shall be as follows:MAKE-BLUESTAR/CARRIER/DAIKIN ODU Rating HP-10

1

-

-

... More
VRV/VRF TYPE INDOOR UNITS : (To be supplied by same manufacturer of outdoor units) Recirculation type Supply,Installation,testing and commissioning of Ceiling hung type 4/1 way Cassette VRF AC units complete with controls prefilter, fan section, DX Coil section and all accessories with fittings as per specification as required. MAKE-BLUESTAR/CARRIER/DAIKIN Four Way Cassette- CFM 1254 - Rating-4.57 TR

14

-

-

... More
VRV/VRF TYPE INDOOR UNITS : (To be supplied by same manufacturer of outdoor units) Recirculation type Supply,Installation,testing and commissioning of Ceiling hung type 4/1 way Cassette VRF AC units complete with controls prefilter, fan section, DX Coil section and all accessories with fittings as per specification as required. MAKE-BLUESTAR/CARRIER/DAIKIN CFM 812 Capacity- 1.6 TR

5

-

-

... More
VRV/VRF TYPE INDOOR UNITS : (To be supplied by same manufacturer of outdoor units) Recirculation type Supply,Installation,testing and commissioning of Ceiling hung type 4/1 way Cassette VRF AC units complete with controls prefilter, fan section, DX Coil section and all accessories with fittings as per specification as required. MAKE-BLUESTAR/CARRIER/DAIKIN CFM 600 Capacity- 1.29 TR

2

-

-

... More
VRV/VRF TYPE INDOOR UNITS : (To be supplied by same manufacturer of outdoor units) Recirculation type Supply,Installation,testing and commissioning of Ceiling hung type 4/1 way Cassette VRF AC units complete with controls prefilter, fan section, DX Coil section and all accessories with fittings as per specification as required. MAKE-BLUESTAR/CARRIER/DAIKIN CFM 865 Capacity- 2.57 TR

21

-

-

... More
VRV/VRF TYPE INDOOR UNITS : (To be supplied by same manufacturer of outdoor units) Recirculation type Supply,Installation,testing and commissioning of Ceiling hung type 4/1 way Cassette VRF AC units complete with controls prefilter, fan section, DX Coil section and all accessories with fittings as per specification as required. MAKE-BLUESTAR/CARRIER/DAIKIN CFM 1183 Capacity- 3.2 TR

21

-

-

... More
AHU, Controls, Expansion Kit, Communication PCB and Thermostat Supply, installation, testing and commissioning of Electronic Type Expansion Kit, Communication PCB with Sensors, Corded Self Diagnostic Type Digital Thermostat, Y-joints etc. as required MAKE-LG/BLUESTAR/CARRIER/DAIKIN. For VRV/VRF DX TFA AHU

8

-

-

... More
HVAC-FITTINGS and CONTROLLERS SITC of Wired Remote Controller for Indoor Units with suitable wiring (1.0sqmm x 2C) in PVC conduit

110

-

-

... More
HVAC-FITTINGS and CONTROLLERS SITC of Centralized remote controller suitable for operation and monitoring of indoor units (106 nos.units). Controller shall be capable of scheduling and BMS compatible.

1

-

-

... More
HVAC-FITTINGS and CONTROLLERS -SITC of fittings :Refnet/Y joints to connect the various indoor units to outdoor unit.

1

-

-

... More
SITC of interconnecting following sizes of hard/ soft drawn seamless refrigerant copper pipe work as per Air Conditioning norms with Y-Joints/Refnets (Considered in separate item and will be paid under that relevant item) and silver soldering joints as required at site and as per specifications insulated with `O` class closed cell electrometric nitrile rubber tubular insulation of fire retardant grade of conductivity less than 0.22 Btu.in/(h.ft² °F) and density 50kg/CMT with thickness 13mm up to 25mm dia pipe and with 19mm for more than 25mm dia pipe between indoor units and Outdoor units as per specifications. All piping inside the builing shall be properly supported with Trays and all External piping shall be supported with covered type Tray (Tray Quantified separately for the same). The Refrigerant pipe sizes and thickness shall be as per manufacturer`s standard. It should be complete as per technical specifications. Outdoor Piping insulation shall have two coats of special UV Resistant Paint (UV Resistant paint shall be quantified separately) Pipe sizes shall be as follows: 41.3 mm O.D - 19 mm thick insulation

150

-

-

... More
SITC of interconnecting following sizes of hard/ soft drawn seamless refrigerant copper pipe work as per Air Conditioning norms with Y-Joints/Refnets (Considered in separate item and will be paid under that relevant item) and silver soldering joints as required at site and as per specifications insulated with `O` class closed cell electrometric nitrile rubber tubular insulation of fire retardant grade of conductivity less than 0.22 Btu.in/(h.ft² °F) and density 50kg/CMT with thickness 13mm up to 25mm dia pipe and with 19mm for more than 25mm dia pipe between indoor units and Outdoor units as per specifications. All piping inside the builing shall be properly supported with Trays and all External piping shall be supported with covered type Tray (Tray Quantified separately for the same). The Refrigerant pipe sizes and thickness shall be as per manufacturer`s standard. It should be complete as per technical specifications. Outdoor Piping insulation shall have two coats of special UV Resistant Paint (UV Resistant paint shall be quantified separately) Pipe sizes shall be as follows: 34.9 mm O.D - 19 mm thick insulation

250

-

-

... More
SITC of interconnecting following sizes of hard/ soft drawn seamless refrigerant copper pipe work as per Air Conditioning norms with Y-Joints/Refnets (Considered in separate item and will be paid under that relevant item) and silver soldering joints as required at site and as per specifications insulated with `O` class closed cell electrometric nitrile rubber tubular insulation of fire retardant grade of conductivity less than 0.22 Btu.in/(h.ft² °F) and density 50kg/CMT with thickness 13mm up to 25mm dia pipe and with 19mm for more than 25mm dia pipe between indoor units and Outdoor units as per specifications. The Refrigerant pipe sizes and thickness shall be as per manufacturer`s standard. It should be complete as per technical specifications. Outdoor Piping insulation shall have two coats of special UV Resistant Paint (UV Resistant paint shall be quantified separately) Pipe sizes shall be as follows: 28.6 mm O.D - 19 mm thick insulation

450

-

-

... More
SITC of interconnecting following sizes of hard/ soft drawn seamless refrigerant copper pipe work as per Air Conditioning norms with Y-Joints/Refnets (Considered in separate item and will be paid under that relevant item) and silver soldering joints as required at site and as per specifications insulated with `O` class closed cell electrometric nitrile rubber tubular insulation of fire retardant grade of conductivity less than 0.22 Btu.in/(h.ft² °F) and density 50kg/CMT with thickness 13mm up to 25mm dia pipe and with 19mm for more than 25mm dia pipe between indoor units and Outdoor units as per specifications. The Refrigerant pipe sizes and thickness shall be as per manufacturer`s standard. It should be complete as per technical specifications. Outdoor Piping insulation shall have two coats of special UV Resistant Paint (UV Resistant paint shall be quantified separately) Pipe sizes shall be as follows: 22.2 mm O.D - 13 mm thick insulation

650

-

-

... More
SITC of interconnecting following sizes of hard/ soft drawn seamless refrigerant copper pipe work as per Air Conditioning norms with Y-Joints/Refnets (Considered in separate item and will be paid under that relevant item) and silver soldering joints as required at site and as per specifications insulated with `O` class closed cell electrometric nitrile rubber tubular insulation of fire retardant grade of conductivity less than 0.22 Btu.in/(h.ft² °F) and density 50kg/CMT with thickness 13mm up to 25mm dia pipe and with 19mm for more than 25mm dia pipe between indoor units and Outdoor units as per specifications. The Refrigerant pipe sizes and thickness shall be as per manufacturer`s standard. It should be complete as per technical specifications. Outdoor Piping insulation shall have two coats of special UV Resistant Paint (UV Resistant paint shall be quantified separately) Pipe sizes shall be as follows: 19.1 mm O.D - 13 mm thick insulation

150

-

-

... More
SITC of interconnecting following sizes of hard/ soft drawn seamless refrigerant copper pipe work as per Air Conditioning norms with Y-Joints/Refnets (Considered in separate item and will be paid under that relevant item) and silver soldering joints as required at site and as per specifications insulated with `O` class closed cell electrometric nitrile rubber tubular insulation of fire retardant grade of conductivity less than 0.22 Btu.in/(h.ft² °F) and density 50kg/CMT with thickness 13mm up to 25mm dia pipe and with 19mm for more than 25mm dia pipe between indoor units and Outdoor units as per specifications. The Refrigerant pipe sizes and thickness shall be as per manufacturer`s standard. It should be complete as per technical specifications. Outdoor Piping insulation shall have two coats of special UV Resistant Paint (UV Resistant paint shall be quantified separately) Pipe sizes shall be as follows: 15.9 mm O.D - 13 mm thick insulation

270

-

-

... More
SITC of interconnecting following sizes of hard/ soft drawn seamless refrigerant copper pipe work as per Air Conditioning norms with Y-Joints/Refnets (Considered in separate item and will be paid under that relevant item) and silver soldering joints as required at site and as per specifications insulated with `O` class closed cell electrometric nitrile rubber tubular insulation of fire retardant grade of conductivity less than 0.22 Btu.in/(h.ft² °F) and density 50kg/CMT with thickness 13mm up to 25mm dia pipe and with 19mm for more than 25mm dia pipe between indoor units and Outdoor units as per specifications. The Refrigerant pipe sizes and thickness shall be as per manufacturer`s standard. It should be complete as per technical specifications. Outdoor Piping insulation shall have two coats of special UV Resistant Paint (UV Resistant paint shall be quantified separately) Pipe sizes shall be as follows: 12.7 mm O.D - 13 mm thick insulation

240

-

-

... More
SITC of interconnecting following sizes of hard/ soft drawn seamless refrigerant copper pipe work as per Air Conditioning norms with Y-Joints/Refnets (Considered in separate item and will be paid under that relevant item) and silver soldering joints as required at site and as per specifications insulated with `O` class closed cell electrometric nitrile rubber tubular insulation of fire retardant grade of conductivity less than 0.22 Btu.in/(h.ft² °F) and density 50kg/CMT with thickness 13mm up to 25mm dia pipe and with 19mm for more than 25mm dia pipe between indoor units and Outdoor units as per specifications. The Refrigerant pipe sizes and thickness shall be as per manufacturer`s standard. It should be complete as per technical specifications. Outdoor Piping insulation shall have two coats of special UV Resistant Paint (UV Resistant paint shall be quantified separately) Pipe sizes shall be as follows: 9.5 mm O.D - 13 mm thick insulation

750

-

-

... More
SITC of interconnecting following sizes of hard/ soft drawn seamless refrigerant copper pipe work as per Air Conditioning norms with Y-Joints/Refnets (Considered in separate item and will be paid under that relevant item) and silver soldering joints as required at site and as per specifications insulated with `O` class closed cell electrometric nitrile rubber tubular insulation of fire retardant grade of conductivity less than 0.22 Btu.in/(h.ft² °F) and density 50kg/CMT with thickness 13mm up to 25mm dia pipe and with 19mm for more than 25mm dia pipe between indoor units and Outdoor units as per specifications. The Refrigerant pipe sizes and thickness shall be as per manufacturer`s standard. It should be complete as per technical specifications. Outdoor Piping insulation shall have two coats of special UV Resistant Paint (UV Resistant paint shall be quantified separately) Pipe sizes shall be as follows: 6.4 mm O.D - 13 mm thick insulation

250

-

-

... More
HVAC-CONTROL CABLING Providing and fixing control cum transmission wiring of 2 core x 1.5 sqmm copper in suitable 25 mm dia heavy duty PVC conduits or wall chase between indoor units and outdoor units and indoor units and remote controllers.

2500

-

-

... More
HVAC- Condensate Drain Piping Providing and Fixing UPVC6kg/cm² pipes of various sizes with 6mm nitrile insulation for condensed water drainage from indoor unit to nearest disposal point in Toilet/Outside rain water harvesting system as per specification 25 mm dia pipe

750

-

-

... More
HVAC- Condensate Drain Piping Providing and Fixing UPVC6kg/cm² pipes of various sizes with 6mm nitrile insulation for condensed water drainage from indoor unit to nearest disposal point in Toilet/Outside rain water harvesting system as per specification 32 mm dia pipe

500

-

-

... More
HVAC- Condensate Drain Piping Providing and Fixing UPVC6kg/cm² pipes of various sizes with 6mm nitrile insulation for condensed water drainage from indoor unit to nearest disposal point in Toilet/Outside rain water harvesting system as per specification 40 mm dia pipe

560

-

-

... More
Hi Wall Type: `Supply, installation, Testing and Commissioning of Hi Wall Type  Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan with drain pump kit, insulation, pipe connections etc. of various capacities including supporting arrangement with suitable vibration isolator as per specifications and drawings.The cost shall include the cost of power and control cabling and earthing from ODUs to Indoor Units as per drawing including plug top suitable for 15 A/3 pins socket. Indoor unit should have capability to provide cooling/heating as per seasonal weather changes.MAKE-LG/BLUESTAR/CARRIER/DAIKIN` CFM 671 TR 2.03

2

-

-

... More
Hi Wall Type: `Supply, installation, Testing and Commissioning of Hi Wall Type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan with drain pump kit, insulation, pipe connections etc. of various capacities including supporting arrangement with suitable vibration isolator as per specifications and drawings.The cost shall include the cost of power and control cabling and earthing from ODUs to Indoor Units as per drawing including plug top suitable for 15 A/3 pins socket. Indoor unit should have capability to provide cooling/heating as per seasonal weather changes.MAKE-LG/BLUESTAR/CARRIER/DAIKIN` CFM 388 TR 1.03

7

-

-

... More
Hi Wall Type: `Supply, installation, Testing and Commissioning of Hi Wall Type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan with drain pump kit, insulation, pipe connections etc. of various capacities including supporting arrangement with suitable vibration isolator as per specifications and drawings.The cost shall include the cost of power and control cabling and earthing from ODUs to Indoor Units as per drawing including plug top suitable for 15 A/3 pins socket. Indoor unit should have capability to provide cooling/heating as per seasonal weather changes.MAKE-LG/BLUESTAR/CARRIER/DAIKIN` CFM 530 TR 1.60

8

-

-

... More
Hi Wall Type: `Supply, installation, Testing and Commissioning of Hi Wall Type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan with drain pump kit, insulation, pipe connections etc. of various capacities including supporting arrangement with suitable vibration isolator as per specifications and drawings.The cost shall include the cost of power and control cabling and earthing from ODUs to Indoor Units as per drawing including plug top suitable for 15 A/3 pins socket. Indoor unit should have capability to provide cooling/heating as per seasonal weather changes.MAKE-LG/BLUESTAR/CARRIER/DAIKIN` CFM 459 TR 1.29

9

-

-

... More
Ceiling Mounted Ductable Type: `Supply, installation, Testing and Commissioning of  Ceiling Mounted Duct Type  Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan with drain pump kit, insulation, pipe connections etc. of various capacities including supporting arrangement with suitable vibration isolator as per specifications and drawings.The cost shall include the cost of power and control cabling and earthing from ODUs to Indoor Units as per drawing including plug top suitable for 15 A/3 pins socket. Indoor unit should have capability to provide cooling/heating as per seasonal weather changes.MAKE-LG/BLUESTAR/CARRIER/DAIKIN` The units shall be suitable for 230V±6%, 50 Hz. supply and complete with electrical controls and panels. CFM TR Ceiling Suspended AHU 4675 10.90

4

-

-

... More
Ceiling Mounted Ductable Type: `Supply, installation, Testing and Commissioning of Ceiling Mounted Duct Type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan with drain pump kit, insulation, pipe connections etc. of various capacities including supporting arrangement with suitable vibration isolator as per specifications and drawings.The cost shall include the cost of power and control cabling and earthing from ODUs to Indoor Units as per drawing including plug top suitable for 15 A/3 pins socket. Indoor unit should have capability to provide cooling/heating as per seasonal weather changes.MAKE-LG/BLUESTAR/CARRIER/DAIKIN` The units shall be suitable for 230V±6%, 50 Hz. supply and complete with electrical controls and panels. CFM 2825 TR 8.00 Ceiling Suspended AHU

4

-

-

... More
HVAC- Ceiling Mounted Ductable Type-Supply, installation, Testing and Commissioning of Ceiling Mounted Duct Type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan with drain pump kit, insulation, pipe connections etc. of various capacities including supporting arrangement with suitable vibration isolator as per specifications and drawings.The cost shall include the cost of power and control cabling and earthing from ODUs to Indoor Units as per drawing including plug top suitable for 15 A/3 pins socket. Indoor unit should have capability to provide cooling/heating as per seasonal weather changes.MAKE-LG/BLUESTAR/CARRIER/DAIKIN` The units shall be suitable for 230V±6%, 50 Hz. supply and complete with electrical controls and panels. Ceiling Suspended AHU CFM 2047 TR 5.51

5

-

-

... More
HVAC- Ceiling Mounted Ductable Type-Supply, installation, Testing and Commissioning of Ceiling Mounted Duct Type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan with drain pump kit, insulation, pipe connections etc. of various capacities including supporting arrangement with suitable vibration isolator as per specifications and drawings.The cost shall include the cost of power and control cabling and earthing from ODUs to Indoor Units as per drawing including plug top suitable for 15 A/3 pins socket. Indoor unit should have capability to provide cooling/heating as per seasonal weather changes.MAKE-LG/BLUESTAR/CARRIER/DAIKIN` The units shall be suitable for 230V±6%, 50 Hz. supply and complete with electrical controls and panels. Ceiling Suspended AHU CFM 1377 TR 4.00

4

-

-

... More
HVAC- Ceiling Mounted Ductable Type-Supply, installation, Testing and Commissioning of Ceiling Mounted Duct Type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan with drain pump kit, insulation, pipe connections etc. of various capacities including supporting arrangement with suitable vibration isolator as per specifications and drawings.The cost shall include the cost of power and control cabling and earthing from ODUs to Indoor Units as per drawing including plug top suitable for 15 A/3 pins socket. Indoor unit should have capability to provide cooling/heating as per seasonal weather changes.MAKE-LG/BLUESTAR/CARRIER/DAIKIN` The units shall be suitable for 230V±6%, 50 Hz. supply and complete with electrical controls and panels. Ceiling Suspended AHU CFM 1624 TR 4.57

1

-

-

... More
VRV/VRF TYPE INDOOR UNITS: (Treated fresh air units) Ceiling Mounted Ductable Type: Supply, installation, Testing and Commissioning of  Ceiling Mounted Duct Type  Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan with drain pump kit, insulation, pipe connections complete with blower section with blower suitable for static pressure as required, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.4mm) cooling coil of 8 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters efficiency 90% down to 10 micron (MERV 8) and Fine filter (Bag filters) efficiency 99% down to 3 micron (MERV 13), belt drive package with TEFC drive motor suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply, drain connections, stainless steel (18G) drain pan with insulation, necessary vibration isolation arrangement etc. complete as required of following capacities MAKE-LG/BLUESTAR/CARRIER/DAIKIN The units shall be suitable for 230V±6%, 50 Hz. supply and complete with electrical controls and panels. AREA TFA AHU (CFM) 2650 CFM TONNAGE (TR) 10 IDU - (for TFA of fresh air supply to MEETING ROOM)

1

-

-

... More
VRV/VRF TYPE INDOOR UNITS: (Treated fresh air units) Ceiling Mounted Ductable Type: Supply, installation, Testing and Commissioning of Ceiling Mounted Duct Type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan with drain pump kit, insulation, pipe connections complete with blower section with blower suitable for static pressure as required, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.4mm) cooling coil of 8 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters efficiency 90% down to 10 micron (MERV 8) and Fine filter (Bag filters) efficiency 99% down to 3 micron (MERV 13), belt drive package with TEFC drive motor suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply, drain connections, stainless steel (18G) drain pan with insulation, necessary vibration isolation arrangement etc. complete as required of following capacities MAKE-LG/BLUESTAR/CARRIER/DAIKIN The units shall be suitable for 230V±6%, 50 Hz. supply and complete with electrical controls and panels. (CFM) 1300 CFM TONNAGE (TR) 5 IDU - (for TFA of fresh air supply )

1

-

-

... More
VRV/VRF TYPE INDOOR UNITS: (Treated fresh air units) Ceiling Mounted Ductable Type: Supply, installation, Testing and Commissioning of Ceiling Mounted Duct Type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan with drain pump kit, insulation, pipe connections complete with blower section with blower suitable for static pressure as required, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.4mm) cooling coil of 8 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters efficiency 90% down to 10 micron (MERV 8) and Fine filter (Bag filters) efficiency 99% down to 3 micron (MERV 13), belt drive package with TEFC drive motor suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply, drain connections, stainless steel (18G) drain pan with insulation, necessary vibration isolation arrangement etc. complete as required of following capacities MAKE-LG/BLUESTAR/CARRIER/DAIKIN The units shall be suitable for 230V±6%, 50 Hz. supply and complete with electrical controls and panels. (CFM) 1250 CFM TONNAGE (TR) 4.74 IDU - (for TFA of fresh air supply )

2

-

-

... More
VRV/VRF TYPE INDOOR UNITS: (Treated fresh air units) Ceiling Mounted Ductable Type: Supply, installation, Testing and Commissioning of Ceiling Mounted Duct Type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan with drain pump kit, insulation, pipe connections complete with blower section with blower suitable for static pressure as required, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.4mm) cooling coil of 8 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters efficiency 90% down to 10 micron (MERV 8) and Fine filter (Bag filters) efficiency 99% down to 3 micron (MERV 13), belt drive package with TEFC drive motor suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply, drain connections, stainless steel (18G) drain pan with insulation, necessary vibration isolation arrangement etc. complete as required of following capacities MAKE-LG/BLUESTAR/CARRIER/DAIKIN The units shall be suitable for 230V±6%, 50 Hz. supply and complete with electrical controls and panels. (CFM) 1900 CFM TONNAGE (TR) 7.21 IDU - (for TFA of fresh air supply )

1

-

-

... More
VRV/VRF TYPE INDOOR UNITS: (Treated fresh air units) Ceiling Mounted Ductable Type: Supply, installation, Testing and Commissioning of Ceiling Mounted Duct Type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan with drain pump kit, insulation, pipe connections complete with blower section with blower suitable for static pressure as required, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.4mm) cooling coil of 8 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters efficiency 90% down to 10 micron (MERV 8) and Fine filter (Bag filters) efficiency 99% down to 3 micron (MERV 13), belt drive package with TEFC drive motor suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply, drain connections, stainless steel (18G) drain pan with insulation, necessary vibration isolation arrangement etc. complete as required of following capacities MAKE-LG/BLUESTAR/CARRIER/DAIKIN The units shall be suitable for 230V±6%, 50 Hz. supply and complete with electrical controls and panels. (CFM) 2100 CFM TONNAGE (TR) 9.34 IDU - (for TFA of fresh air supply )

1

-

-

... More
VRV/VRF TYPE INDOOR UNITS: (Treated fresh air units) Ceiling Mounted Ductable Type: Supply, installation, Testing and Commissioning of Ceiling Mounted Duct Type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan with drain pump kit, insulation, pipe connections complete with blower section with blower suitable for static pressure as required, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.4mm) cooling coil of 8 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters efficiency 90% down to 10 micron (MERV 8) and Fine filter (Bag filters) efficiency 99% down to 3 micron (MERV 13), belt drive package with TEFC drive motor suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply, drain connections, stainless steel (18G) drain pan with insulation, necessary vibration isolation arrangement etc. complete as required of following capacities MAKE-LG/BLUESTAR/CARRIER/DAIKIN The units shall be suitable for 230V±6%, 50 Hz. supply and complete with electrical controls and panels. (CFM) 1400 CFM TONNAGE (TR) 5.3 IDU - (for TFA of fresh air supply )

1

-

-

... More
HVAC-SUPPLY GRILL Supply, installation, testing and balancing of removable core type , linear, fixed bar extruded aluminium powder coated Supply Air / Return Air / Exhaust Air grills, normal flow, 15° angle one way / two way deflection with all sides flanges.Blade thickness shall be minimum 5mm in front and 1.0 mm in rear side.Grills shall be supplied in accordance with specifications and approved shop drawings.(Aalatech,ductofeb,Zeco) 200 mm/150mm/100mm High Sqm 50

20

-

-

... More
HVAC- AIR DISTRIBUTION WORK FOR AIR CONDITION Rectangular GI Ducting (Factory Made) Supply, fabrication, Installation, testing and commissioning of factory fabricated rectangular/round/elliptical ducts using G.I Sheets (120GSM coating). The price shall include factory fabricated TDF flanges, turning vanes, splitter dampers, supports (factory fabricated, full threaded GI rod/hangers and G.I slotted channel), sealant, neoprene gasket, access door etc. The joints shall be with least leak and shall be tested with pressure testing machine.(Aalatech,ductofeb,Zeco) 24 gauge galvanized sheet steel ( TDF 01- 750mm)

1050

-

-

... More
SUB-HEAD-IIIB : AIR DISTRIBUTION WORK FOR AIR CONDITION Rectangular GI Ducting (Factory Made) Supply, fabrication, Installation, testing and commissioning of factory fabricated rectangular/round/elliptical ducts using G.I Sheets (120GSM coating). The price shall include factory fabricated TDF flanges, turning vanes, splitter dampers, supports (factory fabricated, full threaded GI rod/hangers and G.I slotted channel), sealant, neoprene gasket, access door etc. The joints shall be with least leak and shall be tested with pressure testing machine.(Aalatech,ductofeb,Zeco) 22 gauge galvanized sheet steel ( TDF 751 - 1500mm)

150

-

-

... More
HVAC-SUPPLY/ RETURN AIR DIFFUSERS Supply, installation, testing and balancing of square, rectangular and round extruded aluminium powder coated Supply/ Return Air diffusers. Diffuser shall be with spring loaded removable core type distribution grid , key operated aluminium black matt finish dampers .Diffusers shall be supplied in accordance with specifications and approved shop drawings.(Aalatech,ductofeb,Zeco)

64

-

-

... More
HVAC-SUB-HEAD-IV-THERMAL INSULATION Thermal Insulation(Internal ducting): Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class `O`) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. PARAMOUNT/CANI 19mm thick (TFA Ducts)

1650

-

-

... More
HVAC-Air Purification System (Plasma Ionization with Nano Filter) `The Active Air Purification system should consist of Supply, Installation, Testing and commissioning of Bipolar Ionisation System. The Bipolar Ionisation System must be a combination of Tube Based Model and Needle Point Model (Needle Point should have Nitinol (nickel titanium) Needles) and Carbon Fibre Brush Model, System should produce positive and negative ions for creating a Bio Climate rich in ions and hence neutralising harmful pollutants including pathogens, Volatile Organic Compounds and Particulate Matter. The Carbon Brush self-balancing ionizer should be installed at the fan inlet of fan coil units, VRF cassettes, ductless splits , AHU and Ductable HVAC System. These ionizers should be self-contained in a potted ABS box with a moulded flange and mounting holes and is protected with an inline 500mAglass cartridge fuse. The Needle Point Ionizer should be automatic cleaning needlepoint ionizer producing positive and negative ions that neutralize harmful pollutants and odours in the occupied space. The Needle Point compact unit Should automatically remove dust and dirt build-up on the emitters eliminating the need for any maintenance. The Unit can be easily mounted at the fan inlet of any air handling system, including RTU`s, ptacs, mini-splits, fan coil units and VRF systems. The Unit should accept 12-24 VAC/DC. The Tube Based Model should be a single-tube or double tube or 5 tube unit that can be installed in ductwork utilizing the pre-drilled flange and factory applied gasket. The installer makes a duct cut out and secures the unit with self-tapping sheet metal screws. The unit can also be installed inside an AHU, Treated Fresh Air unit, Heat Recovery Ventilation Unit, utilizing a contractor supplied mounting bracket. Power to the ionization unit should be interlocked with system fan operation. The power input fitting provides easy disconnection of the power supply for servicing the unit. A five position ion level control knob varies the ion output between 50% and 100%. The Life of Tube should be minimum 17600 working hours.` `The Active Air Purification system should consist of Supply, Installation, Testing and commissioning of Bipolar Ionisation System. The Bipolar Ionisation System must be a combination of Tube Based Model and Needle Point Model (Needle Point should have Nitinol (nickel titanium) Needles) and Carbon Fibre Brush Model, System should produce positive and negative ions for creating a Bio Climate rich in ions and hence neutralising harmful pollutants including pathogens, Volatile Organic Compounds and Particulate Matter. The Carbon Brush self-balancing ionizer should be installed at the fan inlet of fan coil units, VRF cassettes, ductless splits , AHU and Ductable HVAC System. These ionizers should be self-contained in a potted ABS box with a moulded flange and mounting holes and is protected with an inline 500mAglass cartridge fuse. The Needle Point Ionizer should be automatic cleaning needlepoint ionizer producing positive and negative ions that neutralize harmful pollutants and odours in the occupied space. The Needle Point compact unit Should automatically remove dust and dirt build-up on the emitters eliminating the need for any maintenance. The Unit can be easily mounted at the fan inlet of any air handling system, including RTU`s, ptacs, mini-splits, fan coil units and VRF systems. The Unit should accept 12-24 VAC/DC. The Tube Based Model should be a single-tube or double tube or 5 tube unit that can be installed in ductwork utilizing the pre-drilled flange and factory applied gasket. The installer makes a duct cut out and secures the unit with self-tapping sheet metal screws. The unit can also be installed inside an AHU, Treated Fresh Air unit, Heat Recovery Ventilation Unit, utilizing a contractor supplied mounting bracket. Power to the ionization unit should be interlocked with system fan operation. The power input fitting provides easy disconnection of the power supply for servicing the unit. A five position ion level control knob varies the ion output between 50% and 100%. The Life of Tube should be minimum 17600 working hours.` `The Active Air Purification system should consist of Supply, Installation, Testing and commissioning of Bipolar Ionisation System. The Bipolar Ionisation System must be a combination of Tube Based Model and Needle Point Model (Needle Point should have Nitinol (nickel titanium) Needles) and Carbon Fibre Brush Model, System should produce positive and negative ions for creating a Bio Climate rich in ions and hence neutralising harmful pollutants including pathogens, Volatile Organic Compounds and Particulate Matter. The Carbon Brush self-balancing ionizer should be installed at the fan inlet of fan coil units, VRF cassettes, ductless splits , AHU and Ductable HVAC System. These ionizers should be self-contained in a potted ABS box with a moulded flange and mounting holes and is protected with an inline 500mAglass cartridge fuse. The Needle Point Ionizer should be automatic cleaning needlepoint ionizer producing positive and negative ions that neutralize harmful pollutants and odours in the occupied space. The Needle Point compact unit Should automatically remove dust and dirt build-up on the emitters eliminating the need for any maintenance. The Unit can be easily mounted at the fan inlet of any air handling system, including RTU`s, ptacs, mini-splits, fan coil units and VRF systems. The Unit should accept 12-24 VAC/DC. The Tube Based Model should be a single-tube or double tube or 5 tube unit that can be installed in ductwork utilizing the pre-drilled flange and factory applied gasket. The installer makes a duct cut out and secures the unit with self-tapping sheet metal screws. The unit can also be installed inside an AHU, Treated Fresh Air unit, Heat Recovery Ventilation Unit, utilizing a contractor supplied mounting bracket. Power to the ionization unit should be interlocked with system fan operation. The power input fitting provides easy disconnection of the power supply for servicing the unit. A five position ion level control knob varies the ion output between 50% and 100%. The Life of Tube should be minimum 17600 working hours.` Product should have UL 867 and UL 2998 certification (for zero ozone emission). The OEM shall have Efficacy test report on COVID from any Internationally/Nationally recognised Laboratory Product should have UL 867 and UL 2998 certification (for zero ozone emission). The OEM shall have Efficacy test report on COVID from any Internationally/Nationally recognised Laboratory Product should have UL 867 and UL 2998 certification (for zero ozone emission). The OEM shall have Efficacy test report on COVID from any Internationally/Nationally recognised Laboratory The System should be capable of providing periodic Preventive maintenance for automated after sales support service in form of notification/alerts and user interaction through dashboard application. The System should be capable of providing periodic Preventive maintenance for automated after sales support service in form of notification/alerts and user interaction through dashboard application. The System should be capable of providing periodic Preventive maintenance for automated after sales support service in form of notification/alerts and user interaction through dashboard application. Supplier must have experience of more than 3 years of executing projects with the same technology products. and have done at least 3 multi-location projects (Private Or Government) Pan India and Minimum Value of each project must be at Least 50 Lac. Supplier must have experience of more than 3 years of executing projects with the same technology products. and have done at least 3 multi-location projects (Private Or Government) Pan India and Minimum Value of each project must be at Least 50 Lac. Supplier must have experience of more than 3 years of executing projects with the same technology products. and have done at least 3 multi-location projects (Private Or Government) Pan India and Minimum Value of each project must be at Least 50 Lac. System should be fitted with Fine Filter Media with very less static drop acceptable upto 5 mmwg of Initial pressure drop wherever requires. System should be fitted with Fine Filter Media with very less static drop acceptable upto 5 mmwg of Initial pressure drop wherever requires. System should be fitted with Fine Filter Media with very less static drop acceptable upto 5 mmwg of Initial pressure drop wherever requires. Following Certifications are mandatory to produce  Following Certifications are mandatory to produce  Following Certifications are mandatory to produce  The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer must be UL 2043 certified. The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer must be UL 2043 certified. The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer must be UL 2043 certified. ·         The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer must have UL-2998 Certification for Safety against Zero Ozone Emission as per recommendation by ASHRAE. ·         The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer must have UL-2998 Certification for Safety against Zero Ozone Emission as per recommendation by ASHRAE. ·         The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer must have UL-2998 Certification for Safety against Zero Ozone Emission as per recommendation by ASHRAE. ·         The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer and Tube Based Model Should be tested on UL or Intertek/ETL to prove conformance to UL 867 for electronic devices. ·         The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer and Tube Based Model Should be tested on UL or Intertek/ETL to prove conformance to UL 867 for electronic devices. ·         The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer and Tube Based Model Should be tested on UL or Intertek/ETL to prove conformance to UL 867 for electronic devices. Other Product Certifications required are ISO16000 , CSA C22.2# 187, and CARB. Other Product Certifications required are ISO16000 , CSA C22.2# 187, and CARB. Other Product Certifications required are ISO16000 , CSA C22.2# 187, and CARB. `Manufacturers shall provide Test report from Internationally/Nationally recognized Lab for proven efficacy on below pathogens with minimum kill rates for the following pathogens given the allotted time and in a space condition: a) SARS-CoV-2 (COVID-19) Human Strain b) MS2 Bacteriophage (Surrogates COVID-19) c) Omicron Variant of SARS-CoV-2 d) H1N1 e) Total Bacterial Count Reduction rate of more than 90% from NABL Accredited Lab f) Yeas and Mold/Total fungal count Reduction rate of more than 90% from NABL Accredited Lab ` `Manufacturers shall provide Test report from Internationally/Nationally recognized Lab for proven efficacy on below pathogens with minimum kill rates for the following pathogens given the allotted time and in a space condition: a) SARS-CoV-2 (COVID-19) Human Strain b) MS2 Bacteriophage (Surrogates COVID-19) c) Omicron Variant of SARS-CoV-2 d) H1N1 e) Total Bacterial Count Reduction rate of more than 90% from NABL Accredited Lab f) Yeas and Mold/Total fungal count Reduction rate of more than 90% from NABL Accredited Lab ` `Manufacturers shall provide Test report from Internationally/Nationally recognized Lab for proven efficacy on below pathogens with minimum kill rates for the following pathogens given the allotted time and in a space condition: a) SARS-CoV-2 (COVID-19) Human Strain b) MS2 Bacteriophage (Surrogates COVID-19) c) Omicron Variant of SARS-CoV-2 d) H1N1 e) Total Bacterial Count Reduction rate of more than 90% from NABL Accredited Lab f) Yeas and Mold/Total fungal count Reduction rate of more than 90% from NABL Accredited Lab ` Make :-IntelliGreen/Air Ultra/ A K Enterprises Make :-IntelliGreen/Air Ultra/ A K Enterprises Make :-IntelliGreen/Air Ultra/ A K Enterprises

107

-

-

... More
HVAC-AIRHANDLING UNIT/AIR WASHER/AIR SCRUBBER/SMOKE EXTRACTION FAN STARTER PANEL Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, dead front, sheet steel, wall mounted Fan starter panels including anchoring into the wall with following details: All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operation through BAS. All starters shall be provided with potential free Contacts for Connections to Building Automation System. The panel shall include the following components and accessories. 14G CRCA Powder Coated panel enclosure with earthing studs and hinged locable doors. IP52 Protection, suitable for 415V, 3 Phase, 4 wire, 50Hz system. Incomer switch shall be TP MCCB (motor duty) of required rating and 20KA fault withstand capacity. MCCB shall be with overload and short circuit protection. R,Y,B LED Type Phase indication lamps with control MCB`s. ON`/OFF/TRIP Indication LED Type lamp with control MCB. Digital voltmeter and digital ammeter with in built selector switches. DOL/Star-delta starter for the ratings given below complete with contactors, over load relay with built in single phase protection. Starter shall be BMS compatible for Remote ON/Off and status monitoring complete with Auto/manual switch. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each Fan panel to facilitate override of the automatic operation. A fire detection relay module for switching `ON` of Fan motor on receiving fire signal and fire damper interlocking. Necessary nos. of auxillary contactors and Relays shall be included in cost as required for the interlocking with AHU fan motor and motorised firedampers. 240/24V AC Step down transformer for powering 24V AC auxillary relay. 3 Nos of Single Pole MCB`s Shall be provided at the incoming section of the starter panel for DDC Panel , fire damper actuator and AHU limit switch/Bulk head lighting.(1Nos. Additional to be considered for Scrubber and Airwasher panels only) Terminal block for power distribution. Note: Vendor to include the cost of all related power and control cabling on GI cable tray along with copper earthing , from Airhandling units,Axial flow fan motors, air washers and scrubbers to control panels. Fire operation fans shall have fire survival cable of suitable size (For sizes of cables, refer to the detailed specifications of Electrical section). DOL starters upto 5.5 KW and beyond star-delta starter shall be considered. The Nos. of Fan control panels/starters shall be as per KW ratings given below: Suitable rating MCCB ,Starter Panel for 1.5 KW Motor

2

-

-

... More
AIRHANDLING UNIT/AIR WASHER/AIR SCRUBBER/SMOKE EXTRACTION FAN STARTER PANEL Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, dead front, sheet steel, wall mounted Fan starter panels including anchoring into the wall with following details: All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operation through BAS. All starters shall be provided with potential free Contacts for Connections to Building Automation System. The panel shall include the following components and accessories. 14G CRCA Powder Coated panel enclosure with earthing studs and hinged locable doors. IP52 Protection, suitable for 415V, 3 Phase, 4 wire, 50Hz system. Incomer switch shall be TP MCCB (motor duty) of required rating and 20KA fault withstand capacity. MCCB shall be with overload and short circuit protection. R,Y,B LED Type Phase indication lamps with control MCB`s. ON`/OFF/TRIP Indication LED Type lamp with control MCB. Digital voltmeter and digital ammeter with in built selector switches. DOL/Star-delta starter for the ratings given below complete with contactors, over load relay with built in single phase protection. Starter shall be BMS compatible for Remote ON/Off and status monitoring complete with Auto/manual switch. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each Fan panel to facilitate override of the automatic operation. A fire detection relay module for switching `ON` of Fan motor on receiving fire signal and fire damper interlocking. Necessary nos. of auxillary contactors and Relays shall be included in cost as required for the interlocking with AHU fan motor and motorised firedampers. 240/24V AC Step down transformer for powering 24V AC auxillary relay. 3 Nos of Single Pole MCB`s Shall be provided at the incoming section of the starter panel for DDC Panel , fire damper actuator and AHU limit switch/Bulk head lighting.(1Nos. Additional to be considered for Scrubber and Airwasher panels only) Terminal block for power distribution. Note: Vendor to include the cost of all related power and control cabling on GI cable tray along with copper earthing , from Airhandling units,Axial flow fan motors, air washers and scrubbers to control panels. Fire operation fans shall have fire survival cable of suitable size (For sizes of cables, refer to the detailed specifications of Electrical section). DOL starters upto 5.5 KW and beyond star-delta starter shall be considered. The Nos. of Fan control panels/starters shall be as per KW ratings given below: Suitable rating MCCB ,Starter Panel for 2.2 KW Motor

4

-

-

... More
AIRHANDLING UNIT/AIR WASHER/AIR SCRUBBER/SMOKE EXTRACTION FAN STARTER PANEL Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, dead front, sheet steel, wall mounted Fan starter panels including anchoring into the wall with following details: All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operation through BAS. All starters shall be provided with potential free Contacts for Connections to Building Automation System. The panel shall include the following components and accessories. 14G CRCA Powder Coated panel enclosure with earthing studs and hinged locable doors. IP52 Protection, suitable for 415V, 3 Phase, 4 wire, 50Hz system. Incomer switch shall be TP MCCB (motor duty) of required rating and 20KA fault withstand capacity. MCCB shall be with overload and short circuit protection. R,Y,B LED Type Phase indication lamps with control MCB`s. ON`/OFF/TRIP Indication LED Type lamp with control MCB. Digital voltmeter and digital ammeter with in built selector switches. DOL/Star-delta starter for the ratings given below complete with contactors, over load relay with built in single phase protection. Starter shall be BMS compatible for Remote ON/Off and status monitoring complete with Auto/manual switch. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each Fan panel to facilitate override of the automatic operation. A fire detection relay module for switching `ON` of Fan motor on receiving fire signal and fire damper interlocking. Necessary nos. of auxillary contactors and Relays shall be included in cost as required for the interlocking with AHU fan motor and motorised firedampers. 240/24V AC Step down transformer for powering 24V AC auxillary relay. 3 Nos of Single Pole MCB`s Shall be provided at the incoming section of the starter panel for DDC Panel , fire damper actuator and AHU limit switch/Bulk head lighting.(1Nos. Additional to be considered for Scrubber and Airwasher panels only) Terminal block for power distribution. Note: Vendor to include the cost of all related power and control cabling on GI cable tray along with copper earthing , from Airhandling units,Axial flow fan motors, air washers and scrubbers to control panels. Fire operation fans shall have fire survival cable of suitable size (For sizes of cables, refer to the detailed specifications of Electrical section). DOL starters upto 5.5 KW and beyond star-delta starter shall be considered. The Nos. of Fan control panels/starters shall be as per KW ratings given below: Suitable rating MCCB ,Starter Panel for 5.5 KW Motor

8

-

-

... More
HVAC- Electrical work-Cables from Isolators to each of ODUs Supplying and laying of following 1100 volt grade XLPE insulated PVC sheathed Copper conductor armoured cables as per specification in existing trenches, cable trays, ducts, over bed of sand, clamped to wall with suitable clamps including, saddles fixing bolts, connecting testing and commissioning. The cost of cable shall include the cost of cable tray. 4 C x 25 sq.mm

200

-

-

... More
HVAC- Electrical work-Cables from Isolators to each of ODUs Supplying and laying of following 1100 volt grade XLPE insulated PVC sheathed Copper conductor armoured cables as per specification in existing trenches, cable trays, ducts, over bed of sand, clamped to wall with suitable clamps including, saddles fixing bolts, connecting testing and commissioning. The cost of cable shall include the cost of cable tray. 4 C x 16 sq.mm

150

-

-

... More
HVAC- Electrical work-Cables from Isolators to each of ODUs Supplying and laying of following 1100 volt grade XLPE insulated PVC sheathed Copper conductor armoured cables as per specification in existing trenches, cable trays, ducts, over bed of sand, clamped to wall with suitable clamps including, saddles fixing bolts, connecting testing and commissioning. The cost of cable shall include the cost of cable tray. 4 C x 10 sq.mm

100

-

-

... More
HVAC- Electrical work-Supply and Installation of Double earthing continuity conductors of G.S.S between isolators and VRV ODU`s(13nos.) as required. Cable end termination of the following XLPE insulated PVC sheathed Copper conductor armoured cables of 1100 volt grade including supplying and fixing of bimettalic crimping lugs, double compression glands with earthing. 4 C x 25 sq.mm

20

-

-

... More
HVAC- Electrical work-Supply and Installation of Double earthing continuity conductors of G.S.S between isolators and VRV ODU`s(13nos.) as required. Cable end termination of the following XLPE insulated PVC sheathed Copper conductor armoured cables of 1100 volt grade including supplying and fixing of bimettalic crimping lugs, double compression glands with earthing. 4 C x 10 sq.mm

10

-

-

... More
HVAC- Electrical work-Isolator Switches With Metal Enclosure 63 A 2/3 pole isolator switch for equipments with sheet metal enclosure, rain protection etc. as required to suit the site condition. (Enclosure shall be suitable for out door installation).

4

-

-

... More
HVAC- Electrical work-Isolator Switches With Metal Enclosure 100A ELCB (300mA),4pole switch for VRV Outdoor units with sheet metal enclosure, rain protection etc. as required to suit the site condition. (Enclosure shall be suitable for out door installation).

6

-

-

... More
HVAC- Electrical work-Isolator Switches With Metal Enclosure 63A ELCB (300mA),4pole switch for VRV Outdoor units with sheet metal enclosure, rain protection etc. as required to suit the site condition. (Enclosure shall be suitable for out door installation).

6

-

-

... More
HVAC- Electrical work-Isolator Switches With Metal Enclosure -40A ELCB (300mA),4pole switch for VRV Outdoor units with sheet metal enclosure, rain protection etc. as required to suit the site condition. (Enclosure shall be suitable for out door installation).

3

-

-

... More
HVAC- Electrical work-Isolator Switches With Metal Enclosure -25A ELCB (300mA),4pole switch for VRV Outdoor units with sheet metal enclosure, rain protection etc. as required to suit the site condition. (Enclosure shall be suitable for out door installation).

3

-

-

... More
HVAC-Ceiling Suspended Ductable/AHU- Air purification for ceiling suspended Ductable indoor units and AHU The air purification system should be suitable to reduce harmful pollutants like particulate matter (PMx), PM 2.5, allergens, pollen, smoke, bacteria, pathogens etc. based on below principle technology viz:Impingement, Polarisation and Agglomeration as a passive air It should be a slim structured unit specifically designed for integration in Return Air path of ceiling suspended indoor units, to centrally capture. It should be equivalent to Merv-14 or Higher efficiency for AHU and Ductable* Units with low pressure drop. It should have 3x working principles and it should be aluminium based or powder coated steel casing and should be self-contained. It should be a US patented technology with UL certified components. The units shall meet ANSI/ASHRAE 52.2 standards and have valid test report to verify filtration efficiency. The Basic Media of Electric Filter shall Carry Class 2 Fire Rating Listing by UL.The CAC filter/Electrostatic percipitator (ESP), which have Metal based collection plate shall not be accepted. The Supplier shall carry UL2998 certification or at least Acknowledgement letter from UL2998 for testing against Zero Ozone Emission. The system shall be integrated with the existing pre-section filter area of AHU. The test report for pressure drop need to be submitted for passive air purification and the same shall be demonstrated at site. Make :-IntelliGreen/Air Ultra/ A K Enterprises Electronic filters should consist of an Internet of Things (IoT) based Smart Filtration option employing a 3-Tier Architecture. This architecture would serve to identify pressure drops across the filter, indicating when a replacement is necessary due to clogged filters. Furthermore, it should gauge levels of filter blockage, enabling scheduled preventive maintenance to ensure sustainability. To facilitate user interaction, a well-designed UI/UX experience in the form of a dashboard is essential, complete with appropriate color-coding. Additionally, the system should generate alerts and notifications via text messages or emails to signal instances of filter clogging or the need for filter replacement. To enhance compatibility, the system must support various communication protocols, including options such as WiFi, Bluetooth Low Energy, Modbus RS485, or LoRaWAN.Make :-IntelliGreen/Air Ultra/ A K Enterprises 610*610*25

10

-

-

... More
HVAC-Ceiling Suspended Ductable/AHU Air purification for ceiling suspended Ductable indoor units and AHU The air purification system should be suitable to reduce harmful pollutants like particulate matter (PMx), PM 2.5, allergens, pollen, smoke, bacteria, pathogens etc. based on below principle technology viz:Impingement, Polarisation and Agglomeration as a passive air It should be a slim structured unit specifically designed for integration in Return Air path of ceiling suspended indoor units, to centrally capture. It should be equivalent to Merv-14 or Higher efficiency for AHU and Ductable* Units with low pressure drop. It should have 3x working principles and it should be aluminium based or powder coated steel casing and should be self-contained. It should be a US patented technology with UL certified components. The units shall meet ANSI/ASHRAE 52.2 standards and have valid test report to verify filtration efficiency. The Basic Media of Electric Filter shall Carry Class 2 Fire Rating Listing by UL.The CAC filter/Electrostatic percipitator (ESP), which have Metal based collection plate shall not be accepted. The Supplier shall carry UL2998 certification or at least Acknowledgement letter from UL2998 for testing against Zero Ozone Emission. The system shall be integrated with the existing pre-section filter area of AHU. The test report for pressure drop need to be submitted for passive air purification and the same shall be demonstrated at site. Make :-IntelliGreen/Air Ultra/ A K Enterprises Electronic filters should consist of an Internet of Things (IoT) based Smart Filtration option employing a 3-Tier Architecture. This architecture would serve to identify pressure drops across the filter, indicating when a replacement is necessary due to clogged filters. Furthermore, it should gauge levels of filter blockage, enabling scheduled preventive maintenance to ensure sustainability. To facilitate user interaction, a well-designed UI/UX experience in the form of a dashboard is essential, complete with appropriate color-coding. Additionally, the system should generate alerts and notifications via text messages or emails to signal instances of filter clogging or the need for filter replacement. To enhance compatibility, the system must support various communication protocols, including options such as WiFi, Bluetooth Low Energy, Modbus RS485, or LoRaWAN.Make :-IntelliGreen/Air Ultra/ A K Enterprises 610*305*25

10

-

-

... More
Ceiling Suspended Ductable/AHU Air purification for ceiling suspended Ductable indoor units and AHU The air purification system should be suitable to reduce harmful pollutants like particulate matter (PMx), PM 2.5, allergens, pollen, smoke, bacteria, pathogens etc. based on below principle technology viz:Impingement, Polarisation and Agglomeration as a passive air It should be a slim structured unit specifically designed for integration in Return Air path of ceiling suspended indoor units, to centrally capture. It should be equivalent to Merv-14 or Higher efficiency for AHU and Ductable* Units with low pressure drop. It should have 3x working principles and it should be aluminium based or powder coated steel casing and should be self-contained. It should be a US patented technology with UL certified components. The units shall meet ANSI/ASHRAE 52.2 standards and have valid test report to verify filtration efficiency. The Basic Media of Electric Filter shall Carry Class 2 Fire Rating Listing by UL.The CAC filter/Electrostatic percipitator (ESP), which have Metal based collection plate shall not be accepted. The Supplier shall carry UL2998 certification or at least Acknowledgement letter from UL2998 for testing against Zero Ozone Emission. The system shall be integrated with the existing pre-section filter area of AHU. The test report for pressure drop need to be submitted for passive air purification and the same shall be demonstrated at site. Make :-IntelliGreen/Air Ultra/ A K Enterprises Electronic filters should consist of an Internet of Things (IoT) based Smart Filtration option employing a 3-Tier Architecture. This architecture would serve to identify pressure drops across the filter, indicating when a replacement is necessary due to clogged filters. Furthermore, it should gauge levels of filter blockage, enabling scheduled preventive maintenance to ensure sustainability. To facilitate user interaction, a well-designed UI/UX experience in the form of a dashboard is essential, complete with appropriate color-coding. Additionally, the system should generate alerts and notifications via text messages or emails to signal instances of filter clogging or the need for filter replacement. To enhance compatibility, the system must support various communication protocols, including options such as WiFi, Bluetooth Low Energy, Modbus RS485, or LoRaWAN.Make :-IntelliGreen/Air Ultra/ A K Enterprises IOT

10

-

-

... More
HVAC-Indoor Air Quality Monitoring System- Supply, Installation, Testing and commissioning of IAQ Monitor to remotely measure the levels of PM 2.5, VOCs, CO2, Temperature, Humidity on a real time basis. The IAQ Monitor shall be capable of getting connected with Wi-Fi. The Monitor should be capable of sending the indoor air quality information on display Screen/Mobile/Workstation as per Client`s requirement. The Monitor should indicate the quality of air through changing the colours on the display screen as per the NAAQS standards and should meet the WELL building standards. The monitor should be a 3 tier architecture including sensor Hardware, secure cloud infrastructure, monitoring apps including dashboard, android/IOS. Quoted price shall be inclusive of all necessary arrangement as required to make the unit proper functional.The Monitor Should be Reset-second class B certified. The System should provide Soft Assistance in form of Notifications and Alerts for Periodic Preventive Maintenance. Make :-IntelliGreen/Air Ultra/ A K Enterprises

1

-

-

... More
STP Deodorization System Supply, Installation, Testing, and Commissioning of Plasma Air Ionizer to improve Indoor air quality by using Bi-polar Ionization technology, producing equal amounts of positive and negative oxygen ions. The system kills microorganism and pathogens, remove Odour, and VOC and reduce dust particle /particulate matter / PM2.5 /PM 10. The product is UL / Intertek listed. The product has minimal or negligible pressure drop andamp: low power consumption. The life of the Tube should be 17,600* hours. The power consumption of 3000 CFM units should not exceed 8 watts. The power consumption of 5000 CFM units should not exceed 16 watts. The power consumption of 10000 CFM units should not exceed 50 watts. The unit shall be installted inside an HVAC unit utilizing a contractor-supply mounting bracket. Power to the ionization unit should be interlocked with the system fan operation. A five-position ion level control knob shall be their to vary the ion output between 50% and 100%. Tube-Based Model Should be Underwriters Laboratories Inc.Standards UL867and UL1995. Classified as plenum rated per UL 2043, file #E313835.Make :-IntelliGreen/Air Ultra/ A K Enterprises

50

-

-

... More
Supply Installation Testing and Commissioning of Network Video Recorder with 12 TB HD Quad-core processor. Operating System Embedded LINUX. IP Camera Input 64 channel. Video Output 1 HDMI, 1 VGA. Compression H.265 plus /H.264 plus dual codec decoding. Video Resolution 3840× 2160, 1920× 1080, 1280× 1024, 1280× 720, 1024× 768. Max 640Mbps (Incoming plus Outcoming) ,Up to 12MP resolution preview and playback. Motion Detection MD Zones: 396(22×18).Hard Disk 2 SATA III ports, up to 10TB Each. Alarm Input 4 Channel, Low Level Effective, Green Terminal Interface. Alarm Output 2 Channel, NO/NC Programmable, Green Terminal Interface. Smart Phone iPhone, iPad, Android Phone. Trigger Events Recording, PTZ, Tour, Video Push, Snapshot, and Screen Tips. Recording Mode Manual, Schedule (Regular, Continuous), MD (Video detection: Motion Detection, Tampering, Video Loss), Stop. Search Mode • Time/Date, MD and Exact search (accurate to second),Smart Search.Backup Mode USB Device/Network. Interface Ports • 1 HDMI, 1 VGA, 2 USB(1 Rear USB3.0,1 Front USB2.0), 1 RS485, 1 RS232. Ethernet 1 RJ-45 port (10/100M/1000M). Make Hikvision/AXIS/Honeywell

3

-

-

... More
`Supply Installation Testing and Commissioning of Layer -2 24 Port Gigabit PoE 10/100/1000Mbps Switch. port1-port 8 can support 250m supply power. PoE Power Budget 250W. LED light 26 Link/Act Indicator light, 16 PoE indicator light, 1 Power indicator light. PoE Standard IEEE 802.3i IEEE 802.3u IEEE 802.3x IEEE 802.3ab IEEE 802.3af IEEE 802.3at. Prioritize the identified video data to make video transmission smoother. Automatic detection power of port, power off and restart the device. Make Cisco/zyxel Cisco/Ericsson.`

7

-

-

... More
CCTV-Supply Installation Testing and Commissioning of 6U rack for switch Mounting with Fan and power Strip, PDU, Hardware Mounting Kit Make: Comrack/HCL/Valrack.

5

-

-

... More
CCTV-Supply Installation Testing and Commissioning of 12U Equipment Rack . Make: Comrack/HCL/Valrack.

1

-

-

... More
CCTV-Supply Installation Testing and Commissioning of 3 Core Power Cable 1.5 sqmm. Make: LEGRAND/AGILON/DALTON)

1500

-

-

... More
CCTV-Supply Installation Testing and Commissioning of 2 KVA UPS Cum Inverter with 1 hr back up: MAKE BPE/ NUMERIC/ Emerson.

1

-

-

... More
VENTILATION SYSTEM Axial Fan For `Supply Air (Normal )` `Supply installation, testing and commissioning of long casing (motor should completely be accommodated inside the fan casing) Vane Axial Fan in MS with powder coated / GSS, Al impeller with adjustable blade angles (Manually Adjustable at Site), bird screen ,gravity louvers, fire retardent flexible connection, necessary nut bolts and directly coupled TEFC Sq.cage induction motor (IE2) (F-class for Supply/ Fresh Air) suitable for 415V±10%, 50 Hz. 3 phase electric supply complete with required hardware etc. All offered fans pitch angle shall be AMCA Certified and Listed on AMCA website (Interpolation of pitch angle shall not be acceptable) and Fan Efficiency Grade ( Min FEG 71, lesser is not acceptable).Thickness of the casing shall not be less than: For Dia (300 to 650) mm – 2mm, Dia (700 to 1140) mm – 3 mm, Dia (1200 to 1400) mm – 4mm and Dia 1600 – 5 mm. All fans after assembly shall be dynamically trim-balanced to ISO1940 and AMCA 204/3 - G2.5 quality grade. Fan Casing should be provided with Special Designed Integral Straightening Vanes (Vanes should be integral part of casing, it should not be provided separately as an accessory) to reduced turbulence provide high performance and low noise level.(Root AIr/Zeco/Himidin)` `Fans for normal application vane axial are to be used. Sound level for normal application fans should not exceed 78 DB(A)@ 3 meter (Room Condition). Incase of not achieving sound , attenutor has to be added. Outlet velocity of the fans should not exceed 15 m/s for normal application.` Space - ( Normal Case) FAN CFM MOTOR KW BASEMENT III ZONE 1 30900 11

4

-

-

... More
SUB-HEAD- I : VENTILATION SYSTEM Axial Fan For `Supply Air (Normal )` `Supply installation, testing and commissioning of long casing (motor should completely be accommodated inside the fan casing) Vane Axial Fan in MS with powder coated / GSS, Al impeller with adjustable blade angles (Manually Adjustable at Site), bird screen ,gravity louvers, fire retardent flexible connection, necessary nut bolts and directly coupled TEFC Sq.cage induction motor (IE2) (F-class for Supply/ Fresh Air) suitable for 415V±10%, 50 Hz. 3 phase electric supply complete with required hardware etc. All offered fans pitch angle shall be AMCA Certified and Listed on AMCA website (Interpolation of pitch angle shall not be acceptable) and Fan Efficiency Grade ( Min FEG 71, lesser is not acceptable).Thickness of the casing shall not be less than: For Dia (300 to 650) mm – 2mm, Dia (700 to 1140) mm – 3 mm, Dia (1200 to 1400) mm – 4mm and Dia 1600 – 5 mm. All fans after assembly shall be dynamically trim-balanced to ISO1940 and AMCA 204/3 - G2.5 quality grade. Fan Casing should be provided with Special Designed Integral Straightening Vanes (Vanes should be integral part of casing, it should not be provided separately as an accessory) to reduced turbulence provide high performance and low noise level.(Root AIr/Zeco/Himidin)` `Fans for normal application vane axial are to be used. Sound level for normal application fans should not exceed 78 DB(A)@ 3 meter (Room Condition). Incase of not achieving sound , attenutor has to be added. Outlet velocity of the fans should not exceed 15 m/s for normal application.` Space - ( Normal Case) FAN CFM MOTOR KW BASEMENT I ZONE 1 20200 7.5

2

-

-

... More
Ventilation-Axial Fan for `Exhaust Air ` `Supply installation, testing and commissioning of long casing (Motor should completely be accommodated inside the fan casing,) Vane Axial Fan in MS with powder coated / GSS, Al impeller with adjustable blade angles (Manually Adjustable at Site), bird screen ,gravity louvers, fire retardent flexible connection, necessary nut bolts and directly coupled TEFC Sq.cage induction motor (IE2) (H Class insulation for Basement Exhaust/ Smoke Exhaust) suitable for 415V±10%, 50 Hz. 3 phase electric supply complete with required hardware etc. All offered fans pitch angle shall be AMCA Certified and Listed on AMCA website (Interpolation of pitch angle shall not be acceptable) and Fan Efficiency Grade (Min FEG 71, lesser is not acceptable).Thickness of the casing shall not be less than: For Dia (300 to 650) mm – 2mm, Dia (700 to 1140) mm – 3 mm, Dia (1200 to 1400) mm – 4mm and Dia 1600 – 5 mm. All fans after assembly shall be dynamically trim-balanced to ISO1940 and AMCA 204/3 - G2.5 quality grade. Fan Casing should be provided with Special Designed Integral Straightening Vanes (Vanes should be integral part of casing, it should not be provided separately as an accessory) to reduced turbulence provide high performance and low noise level. (KRUGAR/ROOTAIR/ZECO)` `Fans for normal application Vane axial are to be used. Sound level for normal application fans should not exceed 78 DB(A)@ 3 meter (Room Condition). Incase of not achieving sound , attenutor has to be added. Outlet velocity of the fans should not exceed 15 m/s for normal application.` `Smoke and heat exhaust fans should be tested and certified for 250 Deg C for 2 hour in accordance to standard `BSEN12101-3:2015 from TUV SUD PSB Singapore or equivalent internationally recognized fire laboratory, proposed fan series should be avaialable on the respective fire laboratory website. Same make of motor should be suplied which has been used during testing of the fan ` Space - ( normal Case) FAN CFM MOTOR KW BASEMENT III ZONE 1 34300 11

4

-

-

... More
Ventilation-Axial Fan for `Exhaust Air ` `Supply installation, testing and commissioning of long casing (Motor should completely be accommodated inside the fan casing,) Vane Axial Fan in MS with powder coated / GSS, Al impeller with adjustable blade angles (Manually Adjustable at Site), bird screen ,gravity louvers, fire retardent flexible connection, necessary nut bolts and directly coupled TEFC Sq.cage induction motor (IE2) (H Class insulation for Basement Exhaust/ Smoke Exhaust) suitable for 415V±10%, 50 Hz. 3 phase electric supply complete with required hardware etc. All offered fans pitch angle shall be AMCA Certified and Listed on AMCA website (Interpolation of pitch angle shall not be acceptable) and Fan Efficiency Grade (Min FEG 71, lesser is not acceptable).Thickness of the casing shall not be less than: For Dia (300 to 650) mm – 2mm, Dia (700 to 1140) mm – 3 mm, Dia (1200 to 1400) mm – 4mm and Dia 1600 – 5 mm. All fans after assembly shall be dynamically trim-balanced to ISO1940 and AMCA 204/3 - G2.5 quality grade. Fan Casing should be provided with Special Designed Integral Straightening Vanes (Vanes should be integral part of casing, it should not be provided separately as an accessory) to reduced turbulence provide high performance and low noise level. (KRUGAR/ROOTAIR/ZECO)` `Fans for normal application Vane axial are to be used. Sound level for normal application fans should not exceed 78 DB(A)@ 3 meter (Room Condition). Incase of not achieving sound , attenutor has to be added. Outlet velocity of the fans should not exceed 15 m/s for normal application.` `Smoke and heat exhaust fans should be tested and certified for 250 Deg C for 2 hour in accordance to standard `BSEN12101-3:2015 from TUV SUD PSB Singapore or equivalent internationally recognized fire laboratory, proposed fan series should be avaialable on the respective fire laboratory website. Same make of motor should be suplied which has been used during testing of the fan ` Space - ( normal Case) FAN CFM MOTOR KW BASEMENT I ZONE 1 22500 7.5

2

-

-

... More
Centrifugal Jet Fan Supply, Installation, Testing and commissioning of approved makes Induced Air Centrifugal Jet fans. Fan shall be AMCA certified for Thrust and Sound performance, balanced to vibration grade of G2.5 as per AMCA 204. Fan shall be complete with GSS casing ( 220 GSM ), MS impeller, Dual speed smoke venting Class H, special rated motor certified for 250 Deg C for 2 Hrs - 415/3P/50Hz.Complete Fan and motor assembly shall be Tested and certified for 250 Deg C for 2 Hrs. fire rating as per BSEN 12101-3:2015 from TUV SUD PSB Singapore or equivalent internationally recognized fire laboratory.(KRUGAR/ROOTAIR/ZECO) The Locationing of the jet fans has to be done in such a way that the Air velocity at any point on the plane of 1m from the ground level should not be less than 0.25m/s during the normal mode The CFD Analysis should be done by Original Equipment manufacturer inorder to get actual jet fan quantity and jet fan positioning. Centrifugal Type Jet fan (11100/5550 CMH, 97/24 Thrust force)

16

-

-

... More
Ventilation-CO Sensors for basement car parking ductless ventilation CO Sensors with range of 700 m2.

11

-

-

... More
Preamble to BOQ for MCC , Distribution Boards and wall mounted Starter Panels General Notes and Specifications as given below shall be applicable to all panels.The vendors shall consider the following details in their item rates, wherever required: Supporting rigid steel framework. Cubicle type, 14 gauge CRCA  sheet steel enclosure. Panel Complete with interconnections and distribution bus bars. Proper bonding to earth. Painting/lettering  on Breakers and distribution boards,  the location  they serve,  Providing on each panel its circuit diagram. Providing cable clamps / supports within distribution boards cable alley. TPN  MCCBs  shall mean 3 pole MCCBs  with adequate size of neutral link. All MCBs shall be of minimum 10 KA breaking capacity. All motor feeders MCCBs shall be of motor duty. Distribution  panels shall be Powder Coated with Siemens gray paint shade Nos. RAL-7032 of IS-5. Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993. IP 52 for indoor panels. IP 55 for outdoor panels with double door enclosure. All  MCCB’s   shall be provided with operating   mechanism  for door interlock. Current density of aluminium  shall be 1 sq mm for 1.0 amps for rated current of bus bars and current density of copper shall be 1 sq.mm for 1.25 amps for rated current of bus bars. Tinned copper earth bus shall be provided through out the length of each board. All measuring instruments (Meters) shall be of digital electronic with LED of approved make and compatible with BAS. All indicating lamps shall be LED type. All current/voltage transformers shall be cast resin type. All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire. All panels shall have provision of the following: Pad locking of Switch board doors. Pad locking of MCCB’s handles in “OFF” Position. Additional set of C.T.s, potential free contacts, connectors, contactors with wiring etc are to be provided for BAS including space required for various transducers in Main Switch Board sections.  Only transducers shall be supplied by BAS contractor. All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation. All PTs / control transformers shall be provided with centre tap earth secondary. All DOL and Star-Delta Starters shall be provided with voltage based SPPR (single phase preventor relay) and 2 nos. of Aux.Contacts for Remote operation/monitor. The Panel fabricator shall provide Aluminium Bus-bars link from Breakers wherever more than two nos. of cables are terminated in the breakers. Readymade 16SWG Sheet steel Enclosure with cutout For MCBs The  breaking  capacity of MCCB’s shall be mentioned  panel  wise. All MCCB’s shall be with thermal magnetic releases upto 250 amps and miroprocessor based above 250 amps capacity, unless specified otherwise. All internal control wiring shall be heat resistant type. Bus bar chamber shall be provided at top only. Incoming and outgoing cable entry shall be from top/bottom as required. Live parts shall not be accessible after opening the door, Transparent acrylic sheet to be provided to cover the same. Spare contacts of ACBs / MCCBs / Relay / Contactor shall be wired upto terminal block. All Switchgear used in Starter Circuit shall be type-2 coordinated. Contactor rating shall be selected as per the kVAR rating of the capacitor bank from capacitor duty contactor range. Vendor to furnish the type-2 coordination chart and capacitor duty contactor selection chart. Protection Releases Microprocessor based (PRMB) and Thermal magnetic (PRTM) shall be as described below . Protection Release Microprocessor Based (PRMB-1) Over-current/long time protection range  105% - 120 % with Time setting short circuit /short time protection range  100% - 1000 % with Time setting Instantaneous short circuit Protection range  200% - 1500 % with Time setting Earth Fault Protection range  20% - 100 % with Time setting Under voltage and over voltage protection Reverse power Current unbalance Phase sequence Measurements Voltage Current Power (Active,Reactive and Apparent) Energy ((Active,Reactive and Apparent) Power factor Frequency Protection Release Microprocessor Based (PRMB-2) Over-current/long time protection range  105% - 120 % with Time setting short circuit /short time protection range  100% - 1000 % with Time setting Instantaneous short circuit Protection range  200% - 1500 % with Time setting Earth Fault Protection range  20% - 100 % with Time setting Measurements Current Protection Release Microprocessor Based (PRMB-3) Over-current/long time protection range  105% - 120 % with Time setting Instantaneous short circuit Protection range  200% - 1500 % with Time setting Protection Release Thermal-Magnetic Based (PRTM) Over-current Short circuit Note: Vendor to include the cost of all related power and control cabling on GI cable tray along with copper earthing , from Airhandling units,Axial flow fan motors, air washers and scrubbers to control panels. Fire operation fans shall have fire survival cable of suitable size (For sizes of cables, refer to the detailed specifications of Electrical section). DOL starters upto 5.5 KW and beyond star-delta starter shall be considered. The Nos. of Fan control panels/starters shall be as per KW ratings given below: Suitable rating MCCB ,Starter Panel for 7.5 KW Motor

4

-

-

... More
Preamble to BOQ for MCC , Distribution Boards and wall mounted Starter Panels General Notes and Specifications as given below shall be applicable to all panels.The vendors shall consider the following details in their item rates, wherever required: Supporting rigid steel framework. Cubicle type, 14 gauge CRCA sheet steel enclosure. Panel Complete with interconnections and distribution bus bars. Proper bonding to earth. Painting/lettering on Breakers and distribution boards, the location they serve, Providing on each panel its circuit diagram. Providing cable clamps / supports within distribution boards cable alley. TPN MCCBs shall mean 3 pole MCCBs with adequate size of neutral link. All MCBs shall be of minimum 10 KA breaking capacity. All motor feeders MCCBs shall be of motor duty. Distribution panels shall be Powder Coated with Siemens gray paint shade Nos. RAL-7032 of IS-5. Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993. IP 52 for indoor panels. IP 55 for outdoor panels with double door enclosure. All MCCB’s shall be provided with operating mechanism for door interlock. Current density of aluminium shall be 1 sq mm for 1.0 amps for rated current of bus bars and current density of copper shall be 1 sq.mm for 1.25 amps for rated current of bus bars. Tinned copper earth bus shall be provided through out the length of each board. All measuring instruments (Meters) shall be of digital electronic with LED of approved make and compatible with BAS. All indicating lamps shall be LED type. All current/voltage transformers shall be cast resin type. All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire. All panels shall have provision of the following: Pad locking of Switch board doors. Pad locking of MCCB’s handles in “OFF” Position. Additional set of C.T.s, potential free contacts, connectors, contactors with wiring etc are to be provided for BAS including space required for various transducers in Main Switch Board sections. Only transducers shall be supplied by BAS contractor. All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation. All PTs / control transformers shall be provided with centre tap earth secondary. All DOL and Star-Delta Starters shall be provided with voltage based SPPR (single phase preventor relay) and 2 nos. of Aux.Contacts for Remote operation/monitor. The Panel fabricator shall provide Aluminium Bus-bars link from Breakers wherever more than two nos. of cables are terminated in the breakers. Readymade 16SWG Sheet steel Enclosure with cutout For MCBs The breaking capacity of MCCB’s shall be mentioned panel wise. All MCCB’s shall be with thermal magnetic releases upto 250 amps and miroprocessor based above 250 amps capacity, unless specified otherwise. All internal control wiring shall be heat resistant type. Bus bar chamber shall be provided at top only. Incoming and outgoing cable entry shall be from top/bottom as required. Live parts shall not be accessible after opening the door, Transparent acrylic sheet to be provided to cover the same. Spare contacts of ACBs / MCCBs / Relay / Contactor shall be wired upto terminal block. All Switchgear used in Starter Circuit shall be type-2 coordinated. Contactor rating shall be selected as per the kVAR rating of the capacitor bank from capacitor duty contactor range. Vendor to furnish the type-2 coordination chart and capacitor duty contactor selection chart. Protection Releases Microprocessor based (PRMB) and Thermal magnetic (PRTM) shall be as described below . Protection Release Microprocessor Based (PRMB-1) Over-current/long time protection range 105% - 120 % with Time setting short circuit /short time protection range 100% - 1000 % with Time setting Instantaneous short circuit Protection range 200% - 1500 % with Time setting Earth Fault Protection range 20% - 100 % with Time setting Under voltage and over voltage protection Reverse power Current unbalance Phase sequence Measurements Voltage Current Power (Active,Reactive and Apparent) Energy ((Active,Reactive and Apparent) Power factor Frequency Protection Release Microprocessor Based (PRMB-2) Over-current/long time protection range 105% - 120 % with Time setting short circuit /short time protection range 100% - 1000 % with Time setting Instantaneous short circuit Protection range 200% - 1500 % with Time setting Earth Fault Protection range 20% - 100 % with Time setting Measurements Current Protection Release Microprocessor Based (PRMB-3) Over-current/long time protection range 105% - 120 % with Time setting Instantaneous short circuit Protection range 200% - 1500 % with Time setting Protection Release Thermal-Magnetic Based (PRTM) Over-current Short circuit Note: Vendor to include the cost of all related power and control cabling on GI cable tray along with copper earthing , from Airhandling units,Axial flow fan motors, air washers and scrubbers to control panels. Fire operation fans shall have fire survival cable of suitable size (For sizes of cables, refer to the detailed specifications of Electrical section). DOL starters upto 5.5 KW and beyond star-delta starter shall be considered. The Nos. of Fan control panels/starters shall be as per KW ratings given below: Suitable rating MCCB ,Starter Panel for 11 KW Motor

8

-

-

... More
DOMESTIC PUMPS AND WATER TREATMENT SYSTEM Providing and fixing single stage Vertical inline Pumping set suitable for operation on 415 volts ± 10%, 3 phase and 50 HZ AC supply. The pump shall be made of C.I casing, bronze impeller (hard finished and dynamically balanced), stainless steel (316) shaft and sleeve with mechanical seal capable of delivering suitable capacity and connected by a flexible coupling to a totally enclosed fan cooled (TEFC) induction motor as per IEC standard. Both pump and motor mounted on common M.S. structural base plate bolted to cement concrete foundations complete with Pressure gauge, gunmetal isolation cock, vibration eliminating pads required as per specification. The pump set includes VFD and pressure switch along with necessary cable from panel to pump panel etc. complete. Domestic Water Transfer Pump (Including VFD) Capacity of Pump - 50 LPM No. of pumps - 1 Set = 2 Nos. (1 w plus 1 s) Head - 65 Mtr Motor HP - 3 HP each (Approx.) or as per manufacturer`s recommendation. Degree of Protection - IP `54` Class of Insulation - `F` Location of Pump - In Pump ROOM

1

-

-

... More
SUBMERSIBLE PUMP Supplying, Installation, Testing and Commissioning of single stage submersible sump pumps of closed coupled construction. The pump shall be made of C.I. body, SS-316 impeller and S.S.-316 shaft, suitable for handling waste water, with motors for drainage application complete with M.S guide rail, galvanised lifting chain of suitable length, fasteners, expansion bolts etc. Sump pump shall be having automatic operation complete with motors, built in suction cable, dry run preventive devices, bottom support frame, guide wires, motor control panel (including, earthing, cable tray, termination, Control cable from plumbing panel to Control Panel of required size and Submersible cable from the control panel to the pump motor), two nos. of sensors/probes for automatic operation complete as per specifications. One additional pair of NO/NC contacts should be available for BMS purposes. Drainage Sump Pump for Plumbing Plant Room Capacity of Pump - 150 LPM No. of Pumps - 1 Set = 2 Nos. (1 W plus 1 S) Head of Pump - 15 Mtr Motor HP - 2.0 HP each (Approx.) or as per manufacturer`s recommendation. Solid handling capacity - 20 mm (Non Cutter Type)

1

-

-

... More
SUBMERSIBLE PUMP Supplying, Installation, Testing and Commissioning of single stage submersible sump pumps of closed coupled construction. The pump shall be made of C.I. body, SS-316 impeller and S.S.-316 shaft, suitable for handling waste water, with motors for drainage application complete with M.S guide rail, galvanised lifting chain of suitable length, fasteners, expansion bolts etc. Sump pump shall be having automatic operation complete with motors, built in suction cable, dry run preventive devices, bottom support frame, guide wires, motor control panel (including, earthing, cable tray, termination, Control cable from plumbing panel to Control Panel of required size and Submersible cable from the control panel to the pump motor), two nos. of sensors/probes for automatic operation complete as per specifications. One additional pair of NO/NC contacts should be available for BMS purposes. Drainage Sump Pump for Basement Capacity of Pump - 150 LPM No. of Pumps - 1 Set = 2 Nos. (1 W plus 1 S) Head of Pump - 20 Mtr Motor HP - 2.5 HP each (Approx.) or as per manufacturer`s recommendation. Solid handling capacity - 20 mm (Non Cutter Type)

2

-

-

... More
Level Controller/ Level Indicators Supply, Installation, Testing and Commisioning of magnetic float type Level Controllers / Indicators having adequete number of switches (Minimum 5 Nos.) for the services mentioned below. Contoller equipment shall be mounted inside the electrical panels of the various pumps, while the sensors shall be installed in the corrosponding tanks (roof or the side wall - as the case may be). Controllers shall have sufficient number of contacts to switch on / off the pumps, indicate status, provide signal for remote indication of water level (either as percentage of full level or in cms) and trigger visual/audio alarm.

2

-

-

... More
Firefighting Pumps and Accessories - NON SCHEDULE ITEMS Supply, installation, testing and commissioning of electrically driven high pressure centrifugal fire hydrant / sprinkler pump, suitable for automatic operation consisting of the following: a) Horizontal, split casing, high pressure singlestage, singleoutlet, centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ AC supply. The installation shall be complete with flexible coupling and coupling guard (as per safety norms enclosed), as required. Fire pump shall have CI casing, CS diffusers, bronze impeller (hard finished and dynamically balanced) and SS (304) Shaft with mechanical seal, capable for delivering 2280 LPM at outlet head of 80 mtr. to ensure a minimum pressure of 3.5 Kg/Sqcm at the farthest or topmost hydrant / sprinkler. The installation shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side. (The pump should be tested for bench mark at factory and shall be gotten approved by the Local fire Authority). Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head. b. Squirrel cage induction motor, TEFC type suitable for operation on 415 volts, 3 phase 50 HZ A.C supply, for the above pump with synchronous speed of 1450 RPM, conforming to IP 55 protection and class F insulation. The motor shall conform to IS 325-1978 (up to date) with flexible coupling and coupling guard, complete as required. c. Common base plate for (a) and (b) from M.S. Channel for required size. d. Suitable cement concrete foundation with cement concrete plaster (design and drawing to be provided by the Contractor while the foundation will be done by others) complete with anti-vibration arrangement of cushy foot mountings.

2

-

-

... More
Supply, installation, testing and commissioning of jockey pump (pressurisation pump) comprising of the following: a. Vertical centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ A.C supply. The installation shall be complete with Flexible coupling and coupling guard, complete as required. The pump casing shall be CI, shaft shall be SS and impeller/ shaft sleeve/casing wearing ring shall be bronze. The pump shall be provided with mechanical seal The system shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side. (The pump should meet the condition and shall be gotten approved by the Local fire Authority). b. Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 Hz AC supply for the above pump with a synchronous speed of 2900 RPM with flexible coupling and coupling guard etc. as required. c. Common base plate for (a) and (b) from M.S. channel as required size. d. Suitable cement concrete foundation with plaster, (design and drawing to be provided by the Contractor while the foundation will be done by others) complete with Antivibration arrangement of cushy foot mounting. For pump defined above and of duty as follows : Hydrant and Sprinkler System Flow : 180 LPM Head : 80 mts

2

-

-

... More
Fire fiting pumps- Providing and fixing electronic type water level indicator with LED panel mounted as required by the Project Manager complete with probes and all control wiring etc.

1

-

-

... More
Non clogging type submercible pumps having C.I. casing and CI impeller complete with all accessories, motor of required capacity, Pressure gauge on delivery line with isolation cock, level controller (with wiring) to control the level of sump automatically. Pumps shall have following duty: Raw Sewage Pumps Flow rate (each) 3 CUM/HR Head 8-10 meter Solid Handling 30 mm

2

-

-

... More
Non clogging type submercible pumps having C.I. casing and CI impeller complete with all accessories, motor of required capacity, Pressure gauge on delivery line with isolation cock, level controller (with wiring) to control the level of sump automatically. Pumps shall have following duty: Plant Room Sump Pumps Flow rate (each) 20 cum/hr Head 10-11 meter Solid Handling 15 mm Qty = 02 Nos (1W/ 1S)

2

-

-

... More
STP-Non clogging type centrifugal pumps capable of handling solids up to 8 mm having C.I. casing and CI impeller complete with all accessories, motor of required capacity, Pressure gauge on delivery line with isolation cock, level controller (with wiring) to control the level of sump automatically. Pumps shall have following duty: Sludge re-circulation Pumps Flow rate (each) 3 cum/hr Head 8-10 meter Quantity = 02 Nos (1W/ 1S)

2

-

-

... More
Non clogging type Screw pump capable of handling solids up to 8 mm having C.I. casing and CI impeller complete with all accessories, motor of required capacity, Pressure gauge on delivery line with isolation cock, level controller (with wiring) to control the level of sump automatically. Pumps shall have following duty: Screw Pump Flow rate (each) 1 cum/hr Head 40 mtr

1

-

-

... More
STP-Air diffusion system shall include the following: Twin-Lobe Air Blowers capable of delivering 55 m3 of free air each at 5000 MMWG driven through `V` belt or directly coupled through flexible coupling to a TEFC motor of suitable HP suitable for 415 ± 10% volts, 3 phase, 50 cycles A.hC. supply - 1 Set.

2

-

-

... More
Air diffusion system shall include the following: Mild Steel (MS)(heavy Class) conforming to IS:1239- 1982 complete with mild steel fittings ® brand such as tees, crosses, plugs, sockets, elbows, reducers, supports and clamps, including painting the pipes with desired shade of colour coding over a coat of primer (Air piping).

1

-

-

... More
Air diffusion system shall include the following: Non clog type air dispersion system capable of handling 3-5 cfm of air with oxygen transfer efficiency of 3-4% per/meter water depth. Air dispersion grid shall be assembled in modular form so that they can be replaced/ repaired easily from platform at the top. and clamps, including painting the pipes with desired shade of colour coding over a coat of primer (Air piping). Type of Diffusers Coarse Bubble (In Equalization Tank and Sludge Holding Tank) Fine Bubble Diffusers (In Fab Tanks)

1

-

-

... More
Air diffusion system shall include the following: Flexible pipes complete with fittings such as tees, crosses, plugs, sockets, elbows, reducers, supports and clamps for submerged air piping.

1

-

-

... More
Centrifugal pumps having C.I. casing and CI impeller complete with all accessories, motor of required capacity, Pressure gauge on delivery line with isolation cock, level controller (with wiring) Pumps shall have following duty: Filter Feed Pumps Flow rate (each) 8 cum/hr Head = 30 - 35 mtr

2

-

-

... More
Centrifugal pumps having C.I. casing and CI impeller complete with all accessories, motor of required capacity, Pressure gauge on delivery line with isolation cock, level controller (with wiring) Pumps shall have following duty: Irrigation Water Transfer Pumps Flow rate (each) 15 cum/hr Head = 25 - 30 mtr

2

-

-

... More
Centrifugal pumps having C.I. casing and CI impeller complete with all accessories, motor of required capacity, Pressure gauge on delivery line with isolation cock, level controller (with wiring) Pumps shall have following duty: Flushing Water Transfer Pumps Flow rate (each) 40 lpm Head 65 mtr

2

-

-

... More
STP-Electrical Panel Supply Installation, testing and commissioning of Electrical Panel suitable for 415 V, 3 Phase, 4 wies, 50Hz power distribution system. The panel shall be free standing floow / wall mounted, sheet metal enclosed flush front dust and venim proof with Aluminium bus bars. The painting shall be done as per relevant ISI codes as specified. Adequate size cable alley shall be provided for each cable bending and termination. (All components would be LandT/Schnieder /GE). Please Note : The Panel Box would be fabricated to as to hold components for stage 2 as well but the components of stage 2 would be installed only in stage 2.

1

-

-

... More
STP-Providing and Fixing Complete wiring and cables for the above equipments. Please note. The cable trays would be installed to hold the cables for Stage 2 as well. The cables for stage 2 would however be installed in stage 2 only)

1

-

-

... More
Electro megnatic flow Meter

2

-

-

... More
Energy Meter

1

-

-

... More
Online pH Meter

1

-

-

... More
Pressure Guages with ball valve

1

-

-

... More
Hypo dosing system (pump and tank)

1

-

-

... More
Supply, installation, testing and commissioning of G.I Pipes Class `C` (Heavy grade) conforming to IS : 1239 with GI Fittings conforming to IS : 1879 such as tees, crosses, plug, socket, elbows, reducers, flange, check nut, flanges and clamps, hanger, structural steel supports as required/directed at Site including cutting and making good the walls etc. complete in all respects. 32 mm nominal bore

5

-

-

... More
Supply, installation, testing and commissioning of G.I Pipes Class `C` (Heavy grade) conforming to IS : 1239 with GI Fittings conforming to IS : 1879 such as tees, crosses, plug, socket, elbows, reducers, flange, check nut, flanges and clamps, hanger, structural steel supports as required/directed at Site including cutting and making good the walls etc. complete in all respects. 40 mm nominal bore

20

-

-

... More
Supply, installation, testing and commissioning of G.I Pipes Class `C` (Heavy grade) conforming to IS : 1239 with GI Fittings conforming to IS : 1879 such as tees, crosses, plug, socket, elbows, reducers, flange, check nut, flanges and clamps, hanger, structural steel supports as required/directed at Site including cutting and making good the walls etc. complete in all respects. 50 mm nominal bore

5

-

-

... More
Supply, installation, testing and commissioning of G.I Pipes Class `C` (Heavy grade) conforming to IS : 1239 with GI Fittings conforming to IS : 1879 such as tees, crosses, plug, socket, elbows, reducers, flange, check nut, flanges and clamps, hanger, structural steel supports as required/directed at Site including cutting and making good the walls etc. complete in all respects. 65 mm nominal bore

5

-

-

... More
Supply, installation, testing and commissioning of G.I Pipes Class `C` (Heavy grade) conforming to IS : 1239 with GI Fittings conforming to IS : 1879 such as tees, crosses, plug, socket, elbows, reducers, flange, check nut, flanges and clamps, hanger, structural steel supports as required/directed at Site including cutting and making good the walls etc. complete in all respects. 80 mm nominal bore

67

-

-

... More
Supply, installation, testing and commissioning of G.I Pipes Class `C` (Heavy grade) conforming to IS : 1239 with GI Fittings conforming to IS : 1879 such as tees, crosses, plug, socket, elbows, reducers, flange, check nut, flanges and clamps, hanger, structural steel supports as required/directed at Site including cutting and making good the walls etc. complete in all respects. 100 mm nominal bore

47

-

-

... More
Supply, installation, testing and commissioning of G.I Pipes Class `C` (Heavy grade) conforming to IS : 1239 with GI Fittings conforming to IS : 1879 such as tees, crosses, plug, socket, elbows, reducers, flange, check nut, flanges and clamps, hanger, structural steel supports as required/directed at Site including cutting and making good the walls etc. complete in all respects. 150 mm nominal bore

15

-

-

... More
Providing two coats of synthetic enamel paint of approved shade on exposed G.I. Pipes conforming to IS:2379 cover a coat of primer, including painting of legends with direction arrow as instructed by the site incharge /consultant. 65 mm nominal bore

5

-

-

... More
Providing two coats of synthetic enamel paint of approved shade on exposed G.I. Pipes conforming to IS:2379 cover a coat of primer, including painting of legends with direction arrow as instructed by the site incharge/consultant. 80 mm nominal bore

67

-

-

... More
Providing two coats of synthetic enamel paint of approved shade on exposed G.I. Pipes conforming to IS:2379 cover a coat of primer, including painting of legends with direction arrow as instructed by the site incharge/consultant. 100 mm nominal bore

47

-

-

... More
Providing two coats of synthetic enamel paint of approved shade on exposed G.I. Pipes conforming to IS:2379 cover a coat of primer, including painting of legends with direction arrow as instructed by the site incharge/consultant. 150 mm nominal bore

15

-

-

... More
Supply, Installation, Testing commissioning of CI slim seal butterfly valve B 190 class (PN16) lever type complete with 2 nos. matching flange rubber insertion, nuts bolts and washer etc. of following sizes 65 mm dia

1

-

-

... More
Supply, Installation, Testing commissioning of CI slim seal butterfly valve B 190 class (PN16) lever type complete with 2 nos. matching flange rubber insertion, nuts bolts and washer etc. of following sizes 80 mm dia

19

-

-

... More
Supply, Installation, Testing commissioning of CI slim seal butterfly valve B 190 class (PN16) lever type complete with 2 nos. matching flange rubber insertion, nuts bolts and washer etc. of following sizes 100 mm dia

8

-

-

... More
Supply, Installation, Testing commissioning of CI slim seal butterfly valve B 190 class (PN16) lever type complete with 2 nos. matching flange rubber insertion, nuts bolts and washer etc. of following sizes 150 mm dia

1

-

-

... More
Supply, Installation, Testing commissioning of forged brass lever operated ball valve class (PN16) of full flow with forged brass ball machined 32 mm dia

1

-

-

... More
Supply, Installation, Testing commissioning of forged brass lever operated ball valve class (PN16) of full flow with forged brass ball machined 40 mm dia

1

-

-

... More
Supply, Installation, Testing commissioning of forged brass lever operated ball valve class (PN16) of full flow with forged brass ball machined 50 mm dia

1

-

-

... More
Supplying, installation, testing and commissioning of double flange CI y-type strainer, screw type for size 50 mm and below and flages type for size 65 mm and above complete with 2 Nos. matching flanges, rubber insertion, nuts, bolts an washer etc. of following 150 mm dia

1

-

-

... More
Providing and, testing and commissioning of dial type pressure gauge with pressure scale of 0 to 15 kg / sq.cm. Provision of isolation cock suitable for maximum pressure of 15 kg / sq.cm shall be included in cost.

4

-

-

... More
Providing and fixing reselient rubber neoprene lined arch vibration eliminators with unit control nuts, bolts, washers, companion flange as per table E complete suitable for working pressure of 15 Kg/sq cm. 80 mm dia

2

-

-

... More
Providing and fixing reselient rubber neoprene lined arch vibration eliminators with unit control nuts, bolts, washers, companion flange as per table E complete suitable for working pressure of 15 Kg/sqcm. 100 mm dia

2

-

-

... More
Providing and fixing mild steel (MS) puddle flanges of required size with 5mm thick mild steel (MS) plate including necessary welding as per details shown on drawings and directions of Engineer-in-charge for water tanks. 25mm dia (4mm wall thickness)

1

-

-

... More
Providing and fixing mild steel (MS) puddle flanges of required size with 5mm thick mild steel (MS) plate including necessary welding as per details shown on drawings and directions of Engineer-in-charge for water tanks. 32mm dia (4mm wall thickness)

2

-

-

... More
Providing and fixing mild steel (MS) puddle flanges of required size with 5mm thick mild steel (MS) plate including necessary welding as per details shown on drawings and directions of Engineer-in-charge for water tanks. 40mm dia (4mm wall thickness)

1

-

-

... More
Providing and fixing mild steel (MS) puddle flanges of required size with 5mm thick mild steel (MS) plate including necessary welding as per details shown on drawings and directions of Engineer-in-charge for water tanks. 50mm dia (4mm wall thickness)

1

-

-

... More
Providing and fixing mild steel (MS) puddle flanges of required size with 5mm thick mild steel (MS) plate including necessary welding as per details shown on drawings and directions of Engineer-in-charge for water tanks. 65mm dia (4mm wall thickness)

2

-

-

... More
Providing and fixing mild steel (MS) puddle flanges of required size with 5mm thick mild steel (MS) plate including necessary welding as per details shown on drawings and directions of Engineer-in-charge for water tanks. 80mm dia (4mm wall thickness)

4

-

-

... More
Providing and fixing mild steel (MS) puddle flanges of required size with 5mm thick mild steel (MS) plate including necessary welding as per details shown on drawings and directions of Engineer-in-charge for water tanks. 100mm dia (4mm wall thickness)

11

-

-

... More
Providing and fixing mild steel (MS) puddle flanges of required size with 5mm thick mild steel (MS) plate including necessary welding as per details shown on drawings and directions of Engineer-in-charge for water tanks. 150mm dia (4mm wall thickness)

6

-

-

... More
Providing, Installation, jointing and testing anti mosquito grating for vent pipe and spare sleeve. 100mm dia

6

-

-

... More
Supply, installation, testing and commissioning of Diesel Engine driven fire pump suitable for automatic operation comprising of the following and conforming to BS 649/IS 10002 all amended upto date. a) Horizontal, split casing, high pressure singlestage, singleoutlet, centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ AC supply. The installation shall be complete with flexible coupling and coupling guard (as per safety norms enclosed), as required. Fire pump shall have CI casing, CS diffusers, bronze impeller (hard finished and dynamically balanced) and SS (304) Shaft with mechanical seal, capable for delivering 2280 LPM at outlet head of 80 mts. to ensure a minimum pressure of 3.5 Kg/Sqcm at the farthest or topmost hydrant / sprinkler. The installation shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side. (The pump should be tested for bench mark at factory and shall be gotten approved by the Local fire Authority). Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head b. Heat exchanger cooled (secondary cooling) diesel engine of speed 1500 RPM suitable for the above pump with automatic starting mechanism and other accessories including fuel tank (fabricated from 3mm MS sheet, painted with two coats of synthetic enamel paint over a coat of primer) of capacity adequate to sustain pump operation for 8 hours continuous working. The tank shall be fitted with Magnetic oil level indicator, MH with cover, drain valve, air vent including structural supports (painted with approved shade), 2 Nos. x 12 volt battery, heat exchanger with necessary piping connections and fittings, flexible coupling, coupling guard and exhaust pipe connection complete as require. c. Common base plate for (a) and (b) from M.S. channel of required size. d. Suitable cement concrete foundation with plaster, (design and drawing to be provided by the Contractor while the foundation will be done by others) complete with antivibration arrangement of cushy foot mountings. e. The rate includes interconnecting cables, foundations and foundation bolts

1

-

-

... More
Supply, Installation, Testing and Commissioning of heavy class Galvanized Iron pipe (confirming to IS:1239 upto 150mm dia and IS 3589 above 200mm dia of Grade 330 with minimum 6.35mm thickness) ncluding cutting, welding and jointing with all fittings i.e tees, bends, elbows, flanges, reducers etc.complete including painting of pipes with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including fabrication of all M.S. structural steel (Hot Deep Galvanized) work for clamping, supporting and hanging the pipes with GI rods (Hot Deep Galvanized) and dash fasteners etc, all complete including cutting holes in brick or RCC walls / slabs and making good the same, as directed by the Engineer in charge. (for all suction and delivery header pipes and exposed pipes in the plant room) Note: Pipe upto 50 mm dia shall be threaded joints, above 50 mm shall be welded joints. 65 mm dia

15

-

-

... More
Supply, Installation, Testing and Commissioning of heavy class Galvanized Iron pipe (confirming to IS:1239 upto 150mm dia and IS 3589 above 200mm dia of Grade 330 with minimum 6.35mm thickness) ncluding cutting, welding and jointing with all fittings i.e tees, bends, elbows, flanges, reducers etc.complete including painting of pipes with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including fabrication of all M.S. structural steel (Hot Deep Galvanized) work for clamping, supporting and hanging the pipes with GI rods (Hot Deep Galvanized) and dash fasteners etc, all complete including cutting holes in brick or RCC walls / slabs and making good the same, as directed by the Engineer in charge. (for all suction and delivery header pipes and exposed pipes in the plant room) Note: Pipe upto 50 mm dia shall be threaded joints, above 50 mm shall be welded joints. 80 mm dia

25

-

-

... More
Supply, Installation, Testing and Commissioning of heavy class Galvanized Iron pipe (confirming to IS:1239 upto 150mm dia and IS 3589 above 200mm dia of Grade 330 with minimum 6.35mm thickness) ncluding cutting, welding and jointing with all fittings i.e tees, bends, elbows, flanges, reducers etc.complete including painting of pipes with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including fabrication of all M.S. structural steel (Hot Deep Galvanized) work for clamping, supporting and hanging the pipes with GI rods (Hot Deep Galvanized) and dash fasteners etc, all complete including cutting holes in brick or RCC walls / slabs and making good the same, as directed by the Engineer in charge. (for all suction and delivery header pipes and exposed pipes in the plant room) Note: Pipe upto 50 mm dia shall be threaded joints, above 50 mm shall be welded joints. 100 mm dia

25

-

-

... More
Supply, Installation, Testing and Commissioning of heavy class Galvanized Iron pipe (confirming to IS:1239 upto 150mm dia and IS 3589 above 200mm dia of Grade 330 with minimum 6.35mm thickness) ncluding cutting, welding and jointing with all fittings i.e tees, bends, elbows, flanges, reducers etc.complete including painting of pipes with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including fabrication of all M.S. structural steel (Hot Deep Galvanized) work for clamping, supporting and hanging the pipes with GI rods (Hot Deep Galvanized) and dash fasteners etc, all complete including cutting holes in brick or RCC walls / slabs and making good the same, as directed by the Engineer in charge. (for all suction and delivery header pipes and exposed pipes in the plant room) Note: Pipe upto 50 mm dia shall be threaded joints, above 50 mm shall be welded joints. 150 mm dia

60

-

-

... More
Supply, Installation, Testing and Commissioning of heavy class Galvanized Iron pipe (confirming to IS:1239 upto 150mm dia and IS 3589 above 200mm dia of Grade 330 with minimum 6.35mm thickness) ncluding cutting, welding and jointing with all fittings i.e tees, bends, elbows, flanges, reducers etc.complete including painting of pipes with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including fabrication of all M.S. structural steel (Hot Deep Galvanized) work for clamping, supporting and hanging the pipes with GI rods (Hot Deep Galvanized) and dash fasteners etc, all complete including cutting holes in brick or RCC walls / slabs and making good the same, as directed by the Engineer in charge. (for all suction and delivery header pipes and exposed pipes in the plant room) Note: Pipe upto 50 mm dia shall be threaded joints, above 50 mm shall be welded joints. 200 mm dia

10

-

-

... More
Supply, Installation, Testing and Commissioning of heavy class Galvanized Iron pipe (confirming to IS:1239 upto 150mm dia and IS 3589 above 200mm dia of Grade 330 with minimum 6.35mm thickness) ncluding cutting, welding and jointing with all fittings i.e tees, bends, elbows, flanges, reducers etc.complete including painting of pipes with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including fabrication of all M.S. structural steel (Hot Deep Galvanized) work for clamping, supporting and hanging the pipes with GI rods (Hot Deep Galvanized) and dash fasteners etc, all complete including cutting holes in brick or RCC walls / slabs and making good the same, as directed by the Engineer in charge. (for all suction and delivery header pipes and exposed pipes in the plant room) Note: Pipe upto 50 mm dia shall be threaded joints, above 50 mm shall be welded joints. 250 mm dia

10

-

-

... More
Supply, Installation, Testing and Commissioning of heavy class Galvanized Iron pipe (confirming to IS:1239 upto 150mm dia and IS 3589 above 200mm dia of Grade 330 with minimum 6.35mm thickness) ncluding cutting, welding and jointing with all fittings i.e tees, bends, elbows, flanges, reducers etc.complete including painting of pipes with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including fabrication of all M.S. structural steel (Hot Deep Galvanized) work for clamping, supporting and hanging the pipes with GI rods (Hot Deep Galvanized) and dash fasteners etc, all complete including cutting holes in brick or RCC walls / slabs and making good the same, as directed by the Engineer in charge. (for all suction and delivery header pipes and exposed pipes in the plant room) Note: Pipe upto 50 mm dia shall be threaded joints, above 50 mm shall be welded joints. 300 mm dia

10

-

-

... More
Providing and fixing cast iron double flanged Y/T strainer fabricated with stainless steel perforated sheet basket Class PN 16 tested at 20Kg/cm2 including nuts, bolts, gaskets etc complete as per specifications.150 mm dia

2

-

-

... More
Providing and fixing of C.I. Double flanged butterfly valves complete with bolts, nuts, rubber insertions etc.as per IS:13095/API:609 class PN 16 and tested to pressure of 20 kg/cm2 including necessary flanges as required, complete in all respects. (Above 150mm valve should be Gear operator) 65 mm dia

1

-

-

... More
Providing and fixing of C.I. Double flanged butterfly valves complete with bolts, nuts, rubber insertions etc.as per IS:13095/API:609 class PN 16 and tested to pressure of 20 kg/cm2 including necessary flanges as required, complete in all respects. (Above 150mm valve should be Gear operator) 80 mm dia

2

-

-

... More
Providing and fixing of C.I. Double flanged butterfly valves complete with bolts, nuts, rubber insertions etc.as per IS:13095/API:609 class PN 16 and tested to pressure of 20 kg/cm2 including necessary flanges as required, complete in all respects. (Above 150mm valve should be Gear operator) 100 mm dia

5

-

-

... More
Providing and fixing of C.I. Double flanged butterfly valves complete with bolts, nuts, rubber insertions etc.as per IS:13095/API:609 class PN 16 and tested to pressure of 20 kg/cm2 including necessary flanges as required, complete in all respects. (Above 150mm valve should be Gear operator) 150 mm dia

10

-

-

... More
Providing and fixing of C.I. Double flanged butterfly valves complete with bolts, nuts, rubber insertions etc.as per IS:13095/API:609 class PN 16 and tested to pressure of 20 kg/cm2 including necessary flanges as required, complete in all respects. (Above 150mm valve should be Gear operator) 200 mm dia

2

-

-

... More
Providing and fixing Dual plate non return valve complete with bolts, nuts, rubber insertions etc.as per API 594, PN 16 and tested to pressure of 20kg/cm2 including necessary flanges as required, complete in all respects. 80 mm dia

2

-

-

... More
Providing and fixing Dual plate non return valve complete with bolts, nuts, rubber insertions etc.as per API 594, PN 16 and tested to pressure of 20kg/cm2 including necessary flanges as required, complete in all respects. 100 mm dia

3

-

-

... More
Providing and fixing Dual plate non return valve complete with bolts, nuts, rubber insertions etc.as per API 594, PN 16 and tested to pressure of 20kg/cm2 including necessary flanges as required, complete in all respects. 200 mm dia

1

-

-

... More
Providing and fixing MS Class ‘C’ diesel engine exhaust pipe (including all fittings, clamps, steel support) of suitable dia for the engine. The pipe shall be provided with 12 mm thick supercera ceramic fibre rope

45

-

-

... More
Providing, fixing, testing and commissioning of precharged air vessel (size 450 mm dia and 2000 mm height) for pressurization of hydrant / sprinkler system complete with adequate pressure switches (as per design/requirement) with valves to operate as per operating sequences including 25 mm dia drain valve, air release valve with stop cock on the top, 25 mm dia inlet with isolating valve duly painted from inside and outside complete as required.

2

-

-

... More
Supply, installation, testing and commissioning of Pressure switch of approved make for Hydrant pump, Sprinkler pump, water curtain pump jockey pump and Diesel Engine Driven pump including necessary wiring and cut off valve up to central panel and other material as described in specifications.(As per requirement).

5

-

-

... More
Providing and fixing dial type (100 mm) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required.

7

-

-

... More
Supply, installation, testing and commissioning of sight tube (of 3.5 to 4 mm length) with isolation valve at top / bottom, demarcation on tube for making the installation of level indication on the RCC water tank complete.

1

-

-

... More
Providing, fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 14 Kg/cm2 .Providing, fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 14 Kg/cm2 . 150 mm dia

3

-

-

... More
Providing, fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 14 Kg/cm2 .Providing, fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 14 Kg/cm2 . 100 mm dia

5

-

-

... More
Providing, fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 14 Kg/cm2 .Providing, fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 14 Kg/cm2 . 80 mm dia

2

-

-

... More
Supply, installation, testing and commissioning of Installation Control Valve with Gong Bell Unit with tapping, pipes, Valves, interconnecting hoses and pipings complete as required to make it operational.Supply, installation, testing and commissioning of Installation Control Valve with Gong Bell Unit with tapping, pipes, Valves, interconnecting hoses and pipings complete as required to make it operational.

1

-

-

... More
Supply, fabrication, Installation, testing and commissioning of factory fabricated rectangular/round/elliptical ducts using G.I Sheets (120GSM coating). The price shall include factory fabricated TDF flanges, turning vanes, splitter dampers, supports (factory fabricated, full threaded GI rod/hangers and G.I slotted channel), sealant, neoprene gasket, access door etc. The joints shall be with least leak and shall be tested with pressure testing machine. (Aalatech/ductofeb/Zeco) 24 gauge galvanized sheet steel ( TDF 01- 750mm)

10

-

-

... More
Supply, fabrication, Installation, testing and commissioning of factory fabricated rectangular/round/elliptical ducts using G.I Sheets (120GSM coating). The price shall include factory fabricated TDF flanges, turning vanes, splitter dampers, supports (factory fabricated, full threaded GI rod/hangers and G.I slotted channel), sealant, neoprene gasket, access door etc. The joints shall be with least leak and shall be tested with pressure testing machine. (Aalatech/ductofeb/Zeco) 22 gauge galvanized sheet steel ( TDF 01- 750mm)

45

-

-

... More
Supply, fabrication, Installation, testing and commissioning of factory fabricated rectangular/round/elliptical ducts using G.I Sheets (120GSM coating). The price shall include factory fabricated TDF flanges, turning vanes, splitter dampers, supports (factory fabricated, full threaded GI rod/hangers and G.I slotted channel), sealant, neoprene gasket, access door etc. The joints shall be with least leak and shall be tested with pressure testing machine. (Aalatech/ductofeb/Zeco) 20 gauge galvanized sheet steel ( TDF 01- 750mm)

90

-

-

... More
Supply, fabrication, Installation, testing and commissioning of factory fabricated rectangular/round/elliptical ducts using G.I Sheets (120GSM coating). The price shall include factory fabricated TDF flanges, turning vanes, splitter dampers, supports (factory fabricated, full threaded GI rod/hangers and G.I slotted channel), sealant, neoprene gasket, access door etc. The joints shall be with least leak and shall be tested with pressure testing machine. (Aalatech/ductofeb/Zeco) 18 gauge galvanized sheet steel ( TDF 01- 750mm)

100

-

-

... More
Supply, fabrication, Installation, testing and commissioning of site fabricated rectangular ducts using G.I Sheets (120GSM coating). The price shall include factory fabricated MS flanges (wherever required), turning vanes, splitter dampers, supports (factory fabricated, full threaded G.I rod/hangers and G.I slotted channel), sealant, neoprene gasket, access door etc.as required and as per ISI specifications.The joints shall be with least leak and shall be tested with pressure testing machine.(Aalatech/ductofeb/Zeco) 24 gauge galvanized sheet steel

5

-

-

... More
Supply, fabrication, Installation, testing and commissioning of site fabricated rectangular ducts using G.I Sheets (120GSM coating). The price shall include factory fabricated MS flanges (wherever required), turning vanes, splitter dampers, supports (factory fabricated, full threaded G.I rod/hangers and G.I slotted channel), sealant, neoprene gasket, access door etc.as required and as per ISI specifications.The joints shall be with least leak and shall be tested with pressure testing machine.(Aalatech/ductofeb/Zeco) 22 gauge galvanized sheet steel

20

-

-

... More
Supply, fabrication, Installation, testing and commissioning of site fabricated rectangular ducts using G.I Sheets (120GSM coating). The price shall include factory fabricated MS flanges (wherever required), turning vanes, splitter dampers, supports (factory fabricated, full threaded G.I rod/hangers and G.I slotted channel), sealant, neoprene gasket, access door etc.as required and as per ISI specifications.The joints shall be with least leak and shall be tested with pressure testing machine.(Aalatech/ductofeb/Zeco) 20 gauge galvanized sheet steel

25

-

-

... More
Supply, fabrication, Installation, testing and commissioning of site fabricated rectangular ducts using G.I Sheets (120GSM coating). The price shall include factory fabricated MS flanges (wherever required), turning vanes, splitter dampers, supports (factory fabricated, full threaded G.I rod/hangers and G.I slotted channel), sealant, neoprene gasket, access door etc.as required and as per ISI specifications.The joints shall be with least leak and shall be tested with pressure testing machine.(Aalatech/ductofeb/Zeco) 18 gauge galvanized sheet steel

25

-

-

... More
Supply, installation, testing and balancing of Fresh air Extruded Aluminium intake louvers with bird screen and opposed blade box type GI volume control damper complete as per specification and approved shop drawings.Construction/profile of the louvers shall give a protection against the rain and suitable for fixing in the external facade of the building. (Aalatech/ductofeb/Zeco)

12

-

-

... More
Supply, installation, testing and balancing of Exhaust air Extruded Aluminium intake louvers with bird screen complete as per specification and approved shop drawings.Construction/profile of the louvers shall give a protection against the rain and suitable for fixing in the external facade of the building. (Aalatech/ductofeb/Zeco)

15

-

-

... More
Supply, installation, testing and balancing of factory made Bird screen made out of galvanized steel mesh in 20G having diamond pattern with GSS flanges and necessary cross bracings suitable for Fresh/ Exhaust air fans on terrace, complete as per specification and approved shop drawings.(Aalatech/ductofeb/Zeco)

12

-

-

... More
Supplying, laying, fixing, testing and commissioning of following sizes (NB) of ISI marked heavy class M.S. pipes including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, clamps, hangers, flanges, gaskets, nuts, bolts and washers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/ slabs and making good the same etc. complete in all respect as required. (For Internal Hydrant system). Pipes upto 50 mm dia shall be threaded joints, above 50 mm shall be welded joints. For Pipe up to 50 mm dia standard threaded forged steel fitting and Pipe above 50 mm dia standard M.S. fitting with welded joint shall be used. Steel Structural Supports are included in this item. G.I. pipe sleeve of suitable higher size shall be provided wherever the pipe are crossing the wall /floors and sealing the sleeves with glass wool in between and fire sealant compound at either end all as per Project Manager`s requirement. 25 mm dia

50

-

-

... More
Supplying, laying, fixing, testing and commissioning of following sizes (NB) of ISI marked heavy class M.S. pipes including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, clamps, hangers, flanges, gaskets, nuts, bolts and washers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/ slabs and making good the same etc. complete in all respect as required. (For Internal Hydrant system). Pipes upto 50 mm dia shall be threaded joints, above 50 mm shall be welded joints. For Pipe up to 50 mm dia standard threaded forged steel fitting and Pipe above 50 mm dia standard M.S. fitting with welded joint shall be used. Steel Structural Supports are included in this item. G.I. pipe sleeve of suitable higher size shall be provided wherever the pipe are crossing the wall /floors and sealing the sleeves with glass wool in between and fire sealant compound at either end all as per Project Manager`s requirement. 80 mm dia

60

-

-

... More
Supplying, laying, fixing, testing and commissioning of following sizes (NB) of ISI marked heavy class M.S. pipes including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, clamps, hangers, flanges, gaskets, nuts, bolts and washers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/ slabs and making good the same etc. complete in all respect as required. (For Internal Hydrant system). Pipes upto 50 mm dia shall be threaded joints, above 50 mm shall be welded joints. For Pipe up to 50 mm dia standard threaded forged steel fitting and Pipe above 50 mm dia standard M.S. fitting with welded joint shall be used. Steel Structural Supports are included in this item. G.I. pipe sleeve of suitable higher size shall be provided wherever the pipe are crossing the wall /floors and sealing the sleeves with glass wool in between and fire sealant compound at either end all as per Project Manager`s requirement. 100 mm dia

10

-

-

... More
Supplying, laying, fixing, testing and commissioning of following sizes (NB) of ISI marked heavy class M.S. pipes including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, clamps, hangers, flanges, gaskets, nuts, bolts and washers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/ slabs and making good the same etc. complete in all respect as required. (For Internal Hydrant system). Pipes upto 50 mm dia shall be threaded joints, above 50 mm shall be welded joints. For Pipe up to 50 mm dia standard threaded forged steel fitting and Pipe above 50 mm dia standard M.S. fitting with welded joint shall be used. Steel Structural Supports are included in this item. G.I. pipe sleeve of suitable higher size shall be provided wherever the pipe are crossing the wall /floors and sealing the sleeves with glass wool in between and fire sealant compound at either end all as per Project Manager`s requirement. 150 mm dia

770

-

-

... More
Providing and fixing tar based corrosion protection tape ( wrapped with one layer of 4 mm thick PYPKOAT ) complete as per specification by applying with two coats of zinc chromate primer, wrapping tape spirally and thermosealing complete.

600

-

-

... More
Supplying and fixing Single Headed Internal Hydrant Valve oblique pattern with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked, conforming to IS:5290 :1983 type`A` with 80 mm dia flanged inlet, with ABS cap and chain complete with all accessories etc. as required.

26

-

-

... More
Supply, Installation, Testing and Commissioning of 100% synthetic Nflax canvas non-percolating FIRE hose (Type A), I.S.I marked 63mm dia x 15m long with stainless steel male and female couplings (ISI marked) bound and riveted to hose pipes with copper rivets and copper wire as required.

52

-

-

... More
Supplying and fixing Stainless Steel branch pipe with 20mm dia nozzle conforming to IS:903. suitable for installation connections to hose coupling etc. as required.

26

-

-

... More
Supplying and Fixing First Aid Hose Reel, wall mounting swinging type complete with drum and bracket of MS construction, spray painted in Post office Red, confirming to IS 884/1995 with upto date amendments, complete with the following as required. 36 Meter long 20 mm dia water hose Thermoplastic (Textile reinforced) Type - 2 as per IS : 12585 , 25 mm dia ball valve and nozzle. Drum and brackets for fixing the equipments on wall. Connection from riser with stop valve (gun metal) and M.S. Pipe

18

-

-

... More
Supplying, installation, testing and commissioning of weather proof M.S cabinet size 1200 mm x 2100 mm x 600mm deep fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the following: - a)Gunmetal single headed Hydrant valve - 1 No. b)Fire Hoses 63mm, 15 M long with accessories - 2 Nos. c)Short branch - 1 No. d) First Aid hose Reel - 1 No.( e) Fire Extinguisher - 2 Nos. (f) Fireman`s Axe - 1 No. (g) Pressure Gauge - 1 No.

18

-

-

... More
Providing and fixing Weather proof hose cabinets fabricated from 16 g M.S. Sheet with full glass door and locking arrangement, suitable to accommodate 1 Nos. single headed Hydrant landing valve, 2 nos. 15 M long hose and 1 No branch pipe, 2 Nos. fire extinguishers. The cabinet shall be painted with one coat of primer and finished stove enamelled `Fire Red`, `Fire Hose` written on front including suitably mounted on a raised masonry platform as required.(Approx 0.9m x 0.6 m x 0.3 m).

8

-

-

... More
Supplying, Installation, Testing and Commissioning of Butterfly valves of PN 16 rating of following sizes with nitrile Bronze / G.M. seat duly ISI marked and stainless steel stem with lever/gear operation and cast iron body in powder coated finish for fire fighting application complete in all respects confirming to IS: 13095 as required. of 80 mm dia

24

-

-

... More
Supplying, Installation, Testing and Commissioning of Butterfly valves of PN 16 rating of following sizes with nitrile Bronze / G.M. seat duly ISI marked and stainless steel stem with lever/gear operation and cast iron body in powder coated finish for fire fighting application complete in all respects confirming to IS: 13095 as required. of 100 mm dia

2

-

-

... More
Supplying, Installation, Testing and Commissioning of Butterfly valves of PN 16 rating of following sizes with nitrile Bronze / G.M. seat duly ISI marked and stainless steel stem with lever/gear operation and cast iron body in powder coated finish for fire fighting application complete in all respects confirming to IS: 13095 as required. of 150 mm dia

17

-

-

... More
Providing, Installation, Testing and Commissioning of double flanged cast iron Non-Return Valve, PN 1.6 of following sizes confirming to IS : 5312 complete with rubber gasket, Gl bolts, nuts, washers etc. as required. of 150 mm dia

2

-

-

... More
Providing, Installation, Testing and Commissioning of Gun Metal / Bronze Ball Valves with brass body chrome plated of following sizes as required.of 25 mm dia

27

-

-

... More
Supplying and Fixing Orifice Plate made of 6 mm thick, upto 200 mm outer dia. stainless steel with orifice (internal dia.) of required size in between flange and landing valve of external and internal hydrant to reduce pressure to working pressure of 3.5 Kg / cm2 complete as per specifications as required.

35

-

-

... More
Supply, Installation, Testing and Commissioning of 150 mm dia Bourden type, Stainless Steel dial type Pressure Gauge including brass isolation valve and siphon pipe having calibration of 0 - 16 Kg / cm2.

29

-

-

... More
Providing of fire axe`s with rubber handle .

20

-

-

... More
Fabricating, Supplying, Installation, Testing and Commissioning Air Vessel of continuous welded construction with flanged discharge header on the top of each riser fabricated out of 10 mm thick dished ends and 8 mm thick MS sheet, Air Release Valve complete with suitable drain arrangement with 25 mm dia gun metal wheel valve complete with all accessories etc. as required of the following sizes: 1.2 Meter high and 250 mm dia.

2

-

-

... More
Providing and fixing gunmetal collecting head with 63 mm dia instataneous type inlet and 150/100 mm dia flangfed outlet with built in check valve for fire brigade connection to fire tank and fire risers (IS:904-1965) including 16 guage thick M.S. sheet enclosure stove enameled with 8 mm thick glass in Two Way

1

-

-

... More
Providing and fixing gunmetal collecting head with 63 mm dia instataneous type inlet and 150/100 mm dia flangfed outlet with built in check valve for fire brigade connection to fire tank and fire risers (IS:904-1965) including 16 guage thick M.S. sheet enclosure stove enameled with 8 mm thick glass in Four Way

1

-

-

... More
SUPPLY and FIXING OF ISI (IS:15683) marked Water type stored pressure (stored pressure) type capacity 9 ltrs. with gun-metal cap and nozzle and complete in all respects including initial fill and wall suspension bracket. Capacity 9 ltrs. (Inside FHC)

20

-

-

... More
SUPPLY and FIXING OF ABC dry powder conforming to IS:15683, stored pressure type fire extinguishers (Mono ammonium phosphate confirming to IS 14609) minimum 85% effective discharge, finished externally with red enamel paint and fixed to wall with brackets, complete, with internal charge. (Inside FHC) of Capacity : 6 kg

20

-

-

... More
SUPPLY and FIXING OF ISI marked Fire Extinguisher, Clean Agent Automatic Modular Type HFC-227 ea, UL listed Capacity 5 Kg including initial fill and ceiling suspension bracket complete in all respects. (For Electrical Room / Server room / UPS room)

10

-

-

... More
SUPPLY and FIXING OF ISI marked (IS:15683) Portable Fire Extinguisher, Mech. Foam type capacity 9 ltrs with gun-metal cap and nozzle and complete respects in all respects including initial fill and wall suspension. (For Basement Car Parking)

27

-

-

... More
SUPPLY and FIXING OF ISI marked (IS:16018) Portable Fire Extinguisher, Mech. Foam type capacity 45 ltrs with gun-metal cap and nozzle and complete respects in all respects including initial fill and wall suspension. (For DG Room)

1

-

-

... More
SUPPLY and FIXING OF ISI marked (IS:16018) Fire and wall suspension bracket. Extinguisher, Trolley mounted carbon-dioxide type capacity 22.5 kg. flat base including valve, discharge hose of not less than 10 mm dia. I M long complete in all respects including wheeled trolley. (For Fire Plant Room / LT room / Transformer Room / STP)

4

-

-

... More
Supplying, laying, fixing, testing and commissioning of following sizes (NB) of ISI marked heavy class M.S. pipes including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, clamps, hangers, flanges, gaskets, nuts, bolts and washers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/ slabs and making good the same etc. complete in all respect as required. Note:-The Pipes of sizes 150 mm and below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Size 25 mm dia

3820

-

-

... More
Supplying, laying, fixing, testing and commissioning of following sizes (NB) of ISI marked heavy class M.S. pipes including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, clamps, hangers, flanges, gaskets, nuts, bolts and washers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/ slabs and making good the same etc. complete in all respect as required. Note:-The Pipes of sizes 150 mm and below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Size 32 mm dia

500

-

-

... More
Supplying, laying, fixing, testing and commissioning of following sizes (NB) of ISI marked heavy class M.S. pipes including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, clamps, hangers, flanges, gaskets, nuts, bolts and washers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/ slabs and making good the same etc. complete in all respect as required. Note:-The Pipes of sizes 150 mm and below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Size 40 mm dia

950

-

-

... More
Supplying, laying, fixing, testing and commissioning of following sizes (NB) of ISI marked heavy class M.S. pipes including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, clamps, hangers, flanges, gaskets, nuts, bolts and washers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/ slabs and making good the same etc. complete in all respect as required. Note:-The Pipes of sizes 150 mm and below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Size 50 mm dia

700

-

-

... More
Supplying, laying, fixing, testing and commissioning of following sizes (NB) of ISI marked heavy class M.S. pipes including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, clamps, hangers, flanges, gaskets, nuts, bolts and washers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/ slabs and making good the same etc. complete in all respect as required. Note:-The Pipes of sizes 150 mm and below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Size 65 mm dia

730

-

-

... More
Supplying, laying, fixing, testing and commissioning of following sizes (NB) of ISI marked heavy class M.S. pipes including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, clamps, hangers, flanges, gaskets, nuts, bolts and washers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/ slabs and making good the same etc. complete in all respect as required. Note:-The Pipes of sizes 150 mm and below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Size 80 mm dia

325

-

-

... More
Supplying, laying, fixing, testing and commissioning of following sizes (NB) of ISI marked heavy class M.S. pipes including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, clamps, hangers, flanges, gaskets, nuts, bolts and washers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/ slabs and making good the same etc. complete in all respect as required. Note:-The Pipes of sizes 150 mm and below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Size 100 mm dia

10

-

-

... More
Supplying, laying, fixing, testing and commissioning of following sizes (NB) of ISI marked heavy class M.S. pipes including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, clamps, hangers, flanges, gaskets, nuts, bolts and washers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/ slabs and making good the same etc. complete in all respect as required. Note:-The Pipes of sizes 150 mm and below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Size 150 mm dia

655

-

-

... More
Providing and Fixing 15 mm dia gunmetal / brass quartzoid type Sprinkler Head with quartz bulb and set to operate at specified temperature. Upright, 68° C, Chrome plated

1850

-

-

... More
Providing and Fixing 15 mm dia gunmetal / brass quartzoid type Sprinkler Head with quartz bulb and set to operate at specified temperature. Pendent type, 68° C, Chrome plated

1050

-

-

... More
Providing and Fixing 15 mm dia gunmetal / brass quartzoid type Sprinkler Head with quartz bulb and set to operate at specified temperature. Side wall type, 68° C, Chrome plated

70

-

-

... More
Providing and fixing UL Listed flexible connectors consisting of flexible core 1.5 mtr. in length of corrugated stainless steel tubing under the braid, (Braiding to be SS-304, tubing to be SS-304) for minimum working pressure rating of 200 PSI to be installed at connections from branch pipes to pendant sprinklers blow false ceiling as per specification of the manufacturers.

1050

-

-

... More
Supplying and fixing vane type water flow switch suitable for installation on 50 mm to 150 mm dia line for a service pressure upto 20 kg/sq. cm. of Potter / System sensor /Angus

9

-

-

... More
Providing, fixing, te 20 kg/sq. cm. of Potter / System sensor 20 kg/sq. cm. of Potter / System sensor 20 kg/sq. cm. of Potter / System sensorilt-insight glass bypass valve and connected to 80mm drain line.

9

-

-

... More
Providing , Installation, Testing and Commissioning Air release valve for sprinkler riser to release the trapped air inside the sprinkler riser installed at top of riser.

1

-

-

... More
Providing and erecting 3.00 metre high temporary barricading at site: each panel of size 3.0 x 3.0m made of ISMC 100mm posts/horizontal members/bracings covered with 0.5 mm thick color coated sheet. The sheet shall be fixed with 50x6 mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 3.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work).

607.81

-

-

... More
Supply, erection, testing and commissionoing of PIR OCCUPENCY SENSOR upto entire satisfaction of the Engineer-in-charge

95

-

-

... More
IBMS Cabling and conduiting - Supply and laying of Hot Dip Galvanized perforated cable tray - 150X50X1.6MM..

200

-

-

... More
VRV/VRF TYPE INDOOR UNITS: (Treated fresh air units) Ceiling Mounted Ductable Type: Supply, installation, Testing and Commissioning of Ceiling Mounted Duct Type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan with drain pump kit, insulation, pipe connections complete with blower section with blower suitable for static pressure as required, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.4mm) cooling coil of 8 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters efficiency 90% down to 10 micron (MERV 8) and Fine filter (Bag filters) efficiency 99% down to 3 micron (MERV 13), belt drive package with TEFC drive motor suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply, drain connections, stainless steel (18G) drain pan with insulation, necessary vibration isolation arrangement etc. complete as required of following capacities MAKE-LG/BLUESTAR/CARRIER/DAIKIN The units shall be suitable for 230V±6%, 50 Hz. supply and complete with electrical controls and panels. (CFM) 1045 CFM TONNAGE (TR) 4 IDU - (for TFA of fresh air supply )

1

-

-

... More
CCTV-Supply Installation Testing and Commissioning of 43` LED Monitor, HDMI Port.Resolution,1920 x 1080 (FHD),Backlight Type-LED(Edge),Viewing Angle Degree-178x178,Life span (hrs)-30,000,Brightness (cd/m2)-200,or better, Make: Sony/Panasonic/Samsung.

1

-

-

... More
Providing and Laying of uPVC pipes confirming to relevant IS 4985-2000 including all fittings with or without access doors i.e bends, junctions, cowls, offsets, etc., and jointing with Solvent cement as per Manufacturer`s specifications including cutting holes in walls and floors and Trenching and backfilling upto 1.5` wherever required and making good the same complete as directed by the Project-in-Charge. PVC Pipe 75mm X 6 kg/cm2

210

-

-

... More
Providing and Laying of uPVC pipes confirming to relevant IS 4985-2000 including all fittings with or without access doors i.e bends, junctions, cowls, offsets, etc., and jointing with Solvent cement as per Manufacturer`s specifications including cutting holes in walls and floors and Trenching and backfilling upto 1.5` wherever required and making good the same complete as directed by the Project-in-Charge. PVC Pipe 63mm X 6 kg/cm3

426

-

-

... More
Providing and Laying of uPVC pipes confirming to relevant IS 4985-2000 including all fittings with or without access doors i.e bends, junctions, cowls, offsets, etc., and jointing with Solvent cement as per Manufacturer`s specifications including cutting holes in walls and floors and Trenching and backfilling upto 1.5` wherever required and making good the same complete as directed by the Project-in-Charge. PVC Pipe 50mm X 6 kg/cm4

234

-

-

... More
Providing and Laying of uPVC pipes confirming to relevant IS 4985-2000 including all fittings with or without access doors i.e bends, junctions, cowls, offsets, etc., and jointing with Solvent cement as per Manufacturer`s specifications including cutting holes in walls and floors and Trenching and backfilling upto 1.5` wherever required and making good the same complete as directed by the Project-in-Charge. PVC Pipe 40mm X 6 kg/cm5

1254

-

-

... More
Providing and Fixing of Main Line PVC Double Union Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem,Stem O-Ring, non mechanical ,ball Seals with backing seals and with a base which permits maximum penetration into the valve of size 63mm. with pressure rating PN 10

22

-

-

... More
Providing and Fixing of 10` Round Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout.etc. item complete.

13

-

-

... More
Providing and Fixing of flush valve 50/40 mm size with all fittings and accessories complete.

8

-

-

... More
Providing and Fixing of PVC Quick coupling valve 1` made of plastic with locking cover corrosion resistant and stainless steel spring. Including service saddle and riser assembly. etc. item complete.

16

-

-

... More
Providing and Fixing of Plastic Key threads into top of QCV to provide water access And Brass Swivel Elbow. etc. item complete.

8

-

-

... More
Providing and Fixing of 6`Round box with greenlid andcorrugated structure with unique shovel access slot and bolt hole knockout. etc. item complete.

16

-

-

... More
Providing and Fixing of a double acting 2` Air release valve, The Air release valve shall be capable of both releasing and admitting air from and into the line. Including gate valve, service saddle and riser assembly

2

-

-

... More
Providing and Fixing of Pressure Relief Valve with Maximum operating pressure 10kg/cm2 made of plastic and 1.5` in size

1

-

-

... More
Supplying and Fixing of Mono Block Pump (1 W plus 1S) having 6.5 Lps Discharge @ 45-50 Mtr head, with suction delivery, NRV ,with control panel complete. (Make -KSB/KIRLOSKAR )

1

-

-

... More
LPS-Supply of Vertical Electrolytic Copper Lighting Arrester of 16 mm dia, 1000 mm long with Gun Metal base plate . Model : APSAT116A plus APSTB16-253 Make : APS /Hakel

8

-

-

... More
LPS-Supply 8 mm round aluminium conductor for horizontal lightning protection - run in roof. Model : AL8. Make : Hakel / APS

300

-

-

... More
LPS-`Supply of roof conductor holder for 8 mm round aluminium conductor made of Gun Metal for horizontal installation. The distance between each holder should be min of 1 mtr. Model : APSRCS50. Make : Hakel / APS`

140

-

-

... More
LPS-GLUE - Glue is used to fix the conductor holder on roof.

15

-

-

... More
LPS-Supply of T connector for connecting of 8 mm Al round conductor . The connector should be of Gun Metal with SS nuts and bolt. Model : APSTCRC50 , Make : Hakel /APS

20

-

-

... More
LPS-Supply of Cross connector for connecting of 8 mm Al round conductor . The connector should be of Gun Metal with SS nuts and bolt. Model : APSCCRC50 , Make : Hakel /APS

60

-

-

... More
LPS-`Supply of Expansion piece along with connector to compensate the expansion of round 8 mm Al conductor when temperature variation . Connection should be in every 20 mtr. Model : APSEXP50 , Make : Hakel/APS`

35

-

-

... More
LPS-Supply of connector for Expansion piece . The connector should be of Gun Metal with SS nuts and bolt. Model : APSPCRC50, Make : Hakel / APS

25

-

-

... More
LPS-Supply of 6 digit lightning strike counter. Model - LEC06 Make - NEXUS

3

-

-

... More
LPS-`Supply of Test Joint Point for 8 mm round aluminium conductor , the size should be of 25 x 3 x 150 mm copper in ABS boxes. Model : APSTLBCU. Make : Hakel / APS`

4

-

-

... More
LPS-`Supply of UL approved low carbon high tensile steel rod with copper coating of min 254 micron JK Chemrode - 317 CBR the dia should be 17.2 mm with length of 10 feet ( 3000 mm) . The rod shall be as per IEC 62561-2 and approved by UL 467. The rod shall be tested from NABL lab for current discharge not less then 46kA peak. The Chemrode shall be surrounded with 25 kg ( 1 bag) of Earth enhance materiel JK Reslow according to IEC 62561-7 and the Chemical resistance value shall not increase more then 0.067 Om and same will be tested from NABL lab. along with earth pit chamber made up polyplastic. Size of -254x330x260 MM (Model- PPC01) Make :APS/JK/Hakel `

2

-

-

... More
LPS-Supply of Copper Flat of size 25 x 3 mm for connecting of Earthing.

140

-

-

... More
VC-Main Speakers `SITC of Main Auditorium loudspeaker Two-Way Line Array Column with Asymmetrical Vertical Coverage: Speci?cations: System: Components: Four 130 mm (5 in) LF drivers: Sixteen 25 mm (1 in) HF drivers: Frequency Range (-10 dB): 60 Hz – 20 kHz Coverage: Vertical (selectable via switch): Narrow Mode: 25° (2 kHz - 16 kHz) (±10°) Broad Mode: 45° (750 Hz - 16 kHz) (±10°): Horizontal 150° (500 Hz – 8 kHz, ±20°) Sensitivity (2.83V@ 1m) : Narrow: (speech mode) 98 dB (1 kHz - 8 kHz): (music mode) 93 dB (300 Hz - 18 kHz): Broad: (speech mode) 96 dB (1 kHz - 8 kHz): (music mode) 92 dB (300 Hz - 18 kHz) Nominal Impedance: 8 ohms: Power Capacity and Max SPL: : 500 W (2000 W peak), 2 hrs: 350 W (1400 W peak), 100 hrs: : Narrow: (speech mode) 125 dB cont ave (131 peak) : (music mode) 120 dB cont ave (126 peak): Broad: (speech mode) 123 dB cont ave (129 peak): (music mode) 119 dB cont ave (125 peak) Transducers: Low Frequency Drivers: 4 pcs, 130 mm (5 in) drivers, dual magnet neodymium, 38 mm (1.5 in) voice coil, damped blended textile surround, coated diaphragm for moisture, UV, and salt resistance, shielded. High Frequency Drivers: 16 pcs, 25 mm (1 in) drivers, dual magnet neodymium, encased magnet and coated diaphragm for moisture, UV and salt resistance, shielded. Enclosure: Fiberglass reinforced ABS cabinet, painted aluminum grille.`

2

-

-

... More
VC-Delay Speakers `SITC of Delay speakers for under balcony as per following Specifications SYSTEM TYPE: Powered 12” two-way: CABINET: Polypropylene with full steel grille: MAX SPL: 127 dB peak: FREQUENCY RESPONSE (±3 dB): 53 Hz – 20 kHz: POWER RATING: 1300 watts peak: INPUT IMPEDANCE: 10k ohm balanced: COVERAGE PATTERN: 90º (horizontal) x 60º (vertical) nominal: BLUETOOTH: Audio streaming, Bluetooth version 5.0: DSP: 4 presets, feedback suppression, ducking: I/O: 2 XLR/TRS combo mic/line inputs, 1 XLR pass-thru output.`

4

-

-

... More
VC-Amplifier `SITC of Amplifier: Specifications AC Line Voltage and Frequency Configurations Available ( plus /- 10%) 100VAC 50/60 Hz, 110VAC 60 Hz, 220 and 230~240VAC 50 Hz Voltage Gain 42: Sensitivity 1.4V (for full rated power at 4 ohms): Signal to Noise Ratio (ref. rated power, 8 ohms, 1 kHz) ) 103 dB THD (0.5%: Damping Factor (8 ohms, 10 Hz to 400 Hz) )200: Intermodulation Distortion (from full rated output to -30 dB) (0.3%: Frequency Response (at 1W, 20 Hz - 20 kHz) -1 dB Crosstalk )85 dB (below rated 8 ohms power, at 1 kHz): )55 dB (below rated 8 ohms power, at 20 kHz): Input Impedance (nominal) 20 kilohms balanced, 10 kilohms unbalanced Load Impedance 2~8 ohms per channel in Stereo: 4~8 ohms in Bridge. IEC Power Connector 15A`

2

-

-

... More
VC-Gooseneck mike SITC of programmable gooseneck microphone with RED status ring of neck, cardiod polar pattern, integrated on/off switch, bass roll off filter complete with standard accessories as per tender specifications.

2

-

-

... More
VC-Wireless hand held microphone SITC of Digital Wireless hand held microphone with cardioid polarity pattern, Cardioid dynamic capsule system

2

-

-

... More
VC-Wireless headworn microphone SITC of Digital Wireless Headworn microphone with cardioid or better polarity pattern, Cardioid dynamic capsule system

2

-

-

... More
VC-24U A/V Rack System SITC of Equipment rack 24U for Av equipments with castors, cooling fan, PDU, mounting hardware and selves as required.

1

-

-

... More
VC-Connectors SITC OF Connectors : XLR male female, stereo Connectors, one set as required.

1

-

-

... More
VC-Mike cable -SITC OF Microphone Cable: 2 core PVC insulated Cu conduction sheilded microphone cable cable.

700

-

-

... More
VC-speaker cable SITC of Speaker Cable: 2 core 1.5 sq mm PVC insulated Cu conduction loudspeaker cable.

700

-

-

... More
VC-DSP SITC of DSP 2 x 6 speaker management: 2 Input 6 Output Digital Signal Processor with front LCD, Programmable via PC RS232. Built in Crossover, Limiter, Delay, Parametric Eq, Graphic Eq, RTA Mic Input for Auto Eq, AFS etc..

1

-

-

... More
VC-Mixer SITC of analog Mixing console 12 channel

1

-

-

... More
VC-Mike Sitc of Wired mike for vocal: Supply, Installation, Testing and Commissioning of supecardiod wired Dynamic handheld Vocal microphone with 3 pin XLR: freq range 70Hz to 20kHz: sensitivity)2.5mV/Pa, impeadence = 600Ohms

2

-

-

... More
VC-Projector `SITC of 4K Laser projector with ultra wide resolution WUXGA (1920 x 1200) with infinite Contrast, 4k 30P input Support having 6000 Center Lumens. Make : Sony/ Epson/ Panasonic`

1

-

-

... More
VC-Mounting Kit and hardware SITC of Projector Mount Kit , Power Cable of Suitable required length with required accessories complete in all respects.

1

-

-

... More
VC-HDMI Video Input Matrix switcher SITC of Matrix switcher with 4 HDMI Input : 2 Stereo Audio Input with 1 Mic Input : 1 HDMI Output , 1 HD-BaseT Output and 1 Stereo Audio Output : Video Latency: Less than 2 frames : RS-232 , Ethernet .

1

-

-

... More
VC-HDMI Wall plate SITC of HDMI wall plate for connectivity on podium and stage.

1

-

-

... More
VC-HDMI wires Supply and Laying of 1.8Metres HDMI patch cord in existing conduit.

4

-

-

... More
VC-AOC Cables SITC of AOC cables - for 4k connectivity - 20 m

2

-

-

... More
VC-Interactive panel SITC of Intractive Touch LED Display, 4K resolution, 86 inch, with built in android, PC, Storage, Networking, Audio, Video, USB Ports

3

-

-

... More
VC-Wireless lapel mike SITC of Wireless Lapel Microphone: SITC of Digital Wireless Lapel held microphone with cardioid polarity pattern, Cardioid dynamic capsule system

6

-

-

... More
VC-Wireless hand held microphone SITC of Dual Channel Wireless Handheld Microphone: SITC of Digital Wireless hand held microphone with cardioid polarity pattern, Cardioid dynamic capsule system

4

-

-

... More
VC-Ceiling Speakers SITC of ceiling Speaker: 6` Two-way ceiling speaker, 70/100V transformer with 8 O bypass, 90-110° conical coverage, includes Cring and rails for blind mount installation.

30

-

-

... More
VC-Amplifier Amplifier : Supply, Installation, Testing and Commissioning of dual channel front LCD Class D/AB amplifier with min 300W per channel@8 Ohms/ 600Watts per channel @ 4-ohms.

3

-

-

... More
VC-Conference control unit `Supply and Installation of CONFERENCE Control unit. It should have a built in DSP chip which can adjust the audio output and sensitivity automatically. System should have the facility to be able to connect the cameras for look at me feature through required hardware. The control unit Can control up to10 chairman units and 999 delegate units by extension power supply. It should have 128x64pixels digit LCD monitor display, the configurations can be set up and displayed. The system should have auto testing facility when powered on. Should support built-in voting feature. Technical specification:- Frequency response : 50HZ~16KHZ( ±1dBV ) T.H.D. : ?0.1% S/N Ratio : ?85dBV Conference microphone connection: CAT5E cable RJ-45 port x 4 sets Ethernet Technology: 10 MBPS Ethernet. `

3

-

-

... More
VC-Delegate mike unit `Delegate microphone unit:- SITC of Complete Flush Mount Chairman Unit should support Cat5 cabling for digital Series-Parallel, daisy chain/Tree connection and with push to talk, pluggable gooseneck microphone easy to remove when not in use and with light ring for easy identification of the speaker. Microphone length should be 48 cm. Microphone should get auto off when not in use and also get auto activated when someone starts to speak. MIC auto-Off: 10-70 seconds Technical Specification:- Frequency response :100HZ~16KHZ Sensitivity : ?-50dB S/N ratio : ?70dB Auto Gain Control (AGC) -45 ~ 0dB Connections RJ-45 Jack x 2 Earphone jack 3.5Ø Stereo REC jack 3.5Ø Stereo. `

36

-

-

... More
VC-Chairman mike unit `Chairman Microphone Unit:- SITC of Complete Flush Mount Chairman Unit should support Cat5 cabling for digital Series-Parallel daisy chain/Tree connection and with push to talk and priority speak button, pluggable gooseneck microphone easy to remove when not in use and with light ring for easy identification of the speaker. Microphone length should be 48 cm. Microphone should get auto off when not in use and also get auto activated when someone starts to speak. MIC auto-Off: 10-70 seconds Technical Specification:- Frequency response : 100HZ~16KHZ Sensitivity : ?-50dB S/N ratio : ?70dB Auto Gain Control (AGC) -45 0dB Connections RJ-45 Jack x 2 Earphone jack 3.5Ø Stereo REC jack 3.5Ø Stereo.`

3

-

-

... More
VC-SITC of Cable cubby with HDMI , LAN and Power socket

6

-

-

... More
VC-Video conferencing SITC of Video Conferencing system comprising PTZ zoom camera with minimum 12 predefined positions , zooming facility, required wireless mikes , wires and all necessary mounting hardware.

3

-

-

... More
VC-SITC of USB, HDMI wires and any other accessories

3

-

-

... More
VC-Euipment rack Supply and installation of Equipment Rack 16U capacity or more with PDU, Pedestals and required mounting hardware accessories etc.

3

-

-

... More
VC-Display tv supply and installation of 55 inch , 4k LED TV with network connectivity, bluetooth, wifi etc as perfeatures in latest model of 2024.

6

-

-

... More
VC-Audio Matrix SITC of 8 X 8 Digital Audio Matrix Processor: ADI SHARC 21489@450 MHz SIMD. DSP capability:400 MIPS: 1.6 GFLOPS. Applied with the software for managing the operation of all audio channels. Supports adaptive echo cancellation (AEC): 60dB/S convergence rate: 80dB echo cancellation level. Built-in automatic noise suppression (ANS): making the SNR increase 18db. Supports adaptive feedback control (AFC), automatic gain control (AGC): auto-gain control -6dB~ plus 18dB: auto-balance control -12dB~ plus 12dB. Support ducker, ANC, AM, and Gate Mixer. Definable UI for managing and configurating the max. of 30 units. Centralized control: easily one click to control the power of A/V equipment and switch the audio source. USB audio for soft Audio conferencing.

3

-

-

... More
VC-Controller `SITC of Control unit - Control Unit should have the RS-232 interface for the programming purpose for Auto Tracking of Cameras. It should have a built in DSP chip which can adjust the audio output and sensitivity automatically. System should have the facility to be able to connect the cameras for look at me feature through required hardware. The control unit Can control up to10 chairman units and 999 delegate units by extension power supply. It should have 128x64pixels digit LCD monitor display, the configurations can be set up and displayed. The system should have auto testing facility when powered on. Should support built-in voting feature. Technical specification:- Frequency response : 50HZ~16KHZ( ±1dBV ) T.H.D. : ?0.1% S/N Ratio : ?85dBV Conference microphone connection: CAT5E cable RJ-45 port x 4 sets Ethernet Technology: 10 MBPS Ethernet. `

3

-

-

... More
VC-router SITC of wifi router Equipped with the Beamforming technology, with 5400 Mbps Speed. Frequency: 2.4 GHz, 5 GHz. External Antenna.

3

-

-

... More
VC-DSP SITC of DSP: 2 Input 6 Output Digital Signal Processor with front LCD, Programmable via PC RS232. Built in Crossover, Limiter, Delay, Parametric Eq, Graphic Eq, RTA Mic Input for Auto Eq, AFS etc.

3

-

-

... More
VC-Projection Screen SITC of Fixed frame Projection Screen 20` x 15` with high quality white matt projection screen fabric.

1

-

-

... More
FT-SITC 150W LED FLOOD Light. FOR HIGH MASK . PF).95, System Wattage LED 150W with Minium 120 lumens/WATT in 5700k. The Fixture should be of Makes :-PHILIPS/HAVELLS/WIPRO

6

-

-

... More
FT-SITC Pole 8 meter and Solar street light 12 watt led with Minimum 12.8v 30 ah capacity lithium ferro phosphate battery 75wp under stc panel with 12 watt w-led led, dispersed beam,with the use of proper optics and diffuser led should be compliance to ies LM-80(Approved BIS MARK).

20

-

-

... More
FT-Wall mounted fans 400/450 mm dia. make As specified in tender document or approved Consultant. (Metal Body)

50

-

-

... More
FT-SITC Fabrication, supplying, installation, testing and commissioning of Bollard Light having length 750 mm of MS Sheet i/c making designe by Laser cutting, as approved by Engineer Incharge and welding the same, with 10/20 watt warm white 2 feet long LED light fitting and having suitable arrangement to accommodate 2 nos 10 watt warm white 2 feet long LED light, duly painted with one coat of primer and two coat PU paint i/c J-type foundation nut bolt but excluding foundation complet etc. as required..

20

-

-

... More
FT-Supplying, installation, testing and commissioning of Glass door Operator sensor for opening Glass door with fitting and having suitable arrangement to accommodate complet etc. as required..

4

-

-

... More
FT-Supply of Automatic boom barrier shall be consisting of following specifications. Barrier Front Design: Round Barrier, Colour : Silver/Grey Colour, PARKI Electromechanical Drive ,Mechanism 3-6 meters boom arm Illuminated, Boom Arm (Red/Green) ,Opening Speed : 1.5 Sec Reverse on Obstable Detection , intelligent control mechanism, Automatic Fault Detection Arrow , Led Indication on barrier body (Red/Green) ,Duty Cycle 100 %, IP Rating : IP 55, RS 485 Communication complete in all respect. Makes: Houston Systems, USA ( HOUSYS), Metric ( UK), Swarco ( Switzerland), Tiba ( USA) and other equivalent make matching with above specifications and make is to be approved by department.

1

-

-

... More
FT-Providing and fixing of Aluminium housing body self-contained Rechargeable LED Emergency Light with required content and Size Approx. 300 mm x 180 mm, confirming to IS:9583 :1981with Ni-Mh / Ni - Cd Battery, 3 Hrs Back Up, Constant Current Charger, Input Voltage 230 V, 50 Hz including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects required. All as per pre-approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure `A` attached with this BSR. Single sided signage

48

-

-

... More
FT-Providing and fixing of Aluminium housing body self-contained Rechargeable LED Emergency Light with required content and Size Approx. 300 mm x 180 mm, confirming to IS:9583 :1981with Ni-Mh / Ni - Cd Battery, 3 Hrs Back Up, Constant Current Charger, Input Voltage 230 V, 50 Hz including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects required. All as per pre-approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure `A` attached with this BSR. Double sided signage

48

-

-

... More
`Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized and anti - microbial fusion welded, having thermal stability for hot and cold water supply, including all PP - R plain and brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in-Charge. 63mm dia.(PN16)`

165

-

-

... More
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized and anti - microbial fusion welded, having thermal stability for hot and cold water supply, including all PP - R plain and brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in-Charge. 75 mm dia (Water Supply plus Sump Riser) (PN 16)

135

-

-

... More
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized and anti - microbial fusion welded, having thermal stability for hot and cold water supply, including all PP - R plain and brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in-Charge. 110 mm dia (PN 16)

55

-

-

... More
Cutting of Grooves in cement concrete screed with size of 3 mm wide x 3 mm gap in chequered panels of 2 M x 2 M size and filling the groove with PU sealant of Make SIKA / FOSROC / BASF complete in all respects up to the entire satisfaction of the Engineer-In-Charge

4362.61

-

-

... More
Fan and Fittings-Providing and fixing signages as per required content printed on photo luminescent U1000 aluminium sheet of 1.0 mm ( plus -10%) containing Lumigen II as base chemical, covered under UV stabilized coating with suitable colour combination (Glow in dark) with high intensity properties for indoor surface glow visibility not less than 6 hrs. in total darkness and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects required. All as per pre-approved by Engineer in charge. For additional technical parameters of products/ work, attached with this BSR. Single sided signage board

1000

-

-

... More
HVAC-DX type Hi- wall split unit with ecofriendly refrigerant Supply, installing, testing and commissioning of Hi-wall mounted AIR COOLED SPLIT AIR CONDITIONING UNITS as described in specifications. The unit shall be complete with Indoor type fan coil unit and external condensing unit with supporting frame work, rotary/scroll compressor, copper refrigerant piping with insulation and refrigerant. Quoted price shall include cost of electrical panel (as required), cooling thermostat, wiring, control, wiring and earthing. The unit shall be complete in all respects and capacities shall be as follows :MAKE-LG/BLUESTAR/DAIKIN 2.0 TR split air conditioning units Cost to also include 15 RM (distance between indoor and outdoor unit )of copper refrigerant piping and cabling.

1

-

-

... More
HVAC-Plumbing Pumps-Supply, Installation, Testing commissioning of CI dual plate type non-return valves (PN16) screw type for size 50 mm and below flange type for size 65 mm and above complete flanges, rubber insertion, nuts bolts and washer etc. of following sizes 65 mm dia

1

-

-

... More
HVAC-Plumbing Pumps-Supply, Installation, Testing commissioning of CI dual plate type non-return valves (PN16) screw type for size 50 mm and below flange type for size 65 mm and above complete flanges, rubber insertion, nuts bolts and washer etc. of following sizes 80 mm dia

8

-

-

... More
STP- SS Bar screens : 500 x 300 mm

1

-

-

... More
STP-Supplying, installing, testing and commissioning of tertiary treatment systems comprising of a MSEP pressure sand multigrade filter with Frontal Piping, 5 Valve Battery. Filters shall be suitable for flow rate of 7500 LPH at 3.5 Kg/Sqcm working pressure Filter Dia and Height 800x1200mm

1

-

-

... More
STP-Supplying, installing, testing and commissioning of tertiary treatment systems comprising of a MSEP Activated Carbon filter with Frontal Piping, 5 Valve Battery. Filters shall be suitable for flow rate of 7500 LPH at 3.5 Kg/Sqcm working pressure. Filter Dia and Height 800x1300mm

1

-

-

... More
STP-Galvanized Iron (GI)(heavy Class) pipes complete with GI fittings ® brand such as tees, crosses, plugs, sockets, elbows, reducers, supports and clamps, including painting the pipes with desired shade of colour coding over a coat of primer piping for complete liquid piping . -

1

-

-

... More
STP-UV Sterilizer of Alpha / Creative with Capacity 7500 lph

1

-

-

... More
STP-PVC FAB Media

1

-

-

... More
STP-Tube Settler Media with PVC FAB Media

1

-

-

... More
STP-Supply, Installation, Testing and Commissioning of Filter Press (Manual) having 10 Nos Plates having 20` X 20` size.

1

-

-

... More
HVAC-VCDs FOR LINEAR GRILL SUPPLY AIR COLLARS Supply, installation, testing and balancing of key operated extruded Aluminium volume control dampers in black mat finish for supply/return/exhaust air duct collars as per approved shop drawings and specifications. (Aalatech,ductofeb,Zeco) Sqm 25

20

-

-

... More
HVAC-DX type Hi- wall split unit with ecofriendly refrigerant Supply, installing, testing and commissioning of Hi-wall mounted AIR COOLED SPLIT AIR CONDITIONING UNITS as described in specifications. The unit shall be complete with Indoor type fan coil unit and external condensing unit with supporting frame work, rotary/scroll compressor, copper refrigerant piping with insulation and refrigerant. Quoted price shall include cost of electrical panel (as required), cooling thermostat, wiring, control, wiring and earthing. The unit shall be complete in all respects and capacities shall be as follows 1.5 TR split air conditioning units Cost to also include 15 RM (distance between indoor and outdoor unit )of copper refrigerant piping and cabling. :MAKE-BLUESTAR/DAIKIN/Carrier

1

-

-

... More
Fan and Fittings-`SITC Ligman/VAK/KESELEC make decorative Linear Wall Washer Light of 4ft size. Wattage of the light is 28Watt. This light is in IP65 which will be supplied with all accessories.`

50

-

-

... More
Fan and Fittings-`SITC Ligman/VAK/KESELEC make decorative Linear Wall Washer Light of 2ft size. Wattage of the light is 14Watt. This light is in IP65 which will be supplied with all accessories.`

45

-

-

... More
Fan and Fittings-`SITC Ligman/VAK/KESELEC make decorative UP-Down light of 14Watt LED. Size of the light is 210mmX63mm. This light is in IP65 which will be supplied with all accessories.`

50

-

-

... More
Fan and Fittings-`SITC Ligman/KESELEC/VAK make decorative SPIKE Light of 10Watt LED. The size of the spike light is 200mmX60 mm. This light is in IP65 which will be supplied with all accessories`

50

-

-

... More
Fan and Fittings-`SITC Ligman /VAK/KESELECmake decorative LED strip light in 6Watt/metre. The size of this strip light is 10mmX10mm. This light is in IP67 which will be supplied with all accessories.`

50

-

-

... More
SITC of Active Repeator panel (EDWORD/Siemans/JOHNSON CONTROL)..

1

-

-

... More
Lift-Supply Installation testing and commissioning of Passenger (1020 Kg, 15 persons.) Machine Room Less Gearless Elevator with 3 year free comprehensivie warranty period to be supplied and installed in accordance with the following technical specifications: Make:- OTIS/KONE/SHINDLER/JOHNSON/MITSUBISHI CAPACITY (kgs) 1020 Kg, 15 persons. SPEED (mps) 1 mps. RISE (m) 37 M. STOPS 9 Stops With (all opening on the same side). CONTROLLER TYPE ACD3-MRL. DRIVE VF Regenerative (Closed Loop). POWER SUPPLY 400/415 Volts (3 Phase AC). OPERATION Full collective operation. CAR GROUP One car (simplex) MACHINE PM Gearless (Located above shaft). TRACTION MEDIA Flat Coated. Steel Belt. CAR FINISH `• Rear Mid Panel = Stainless Steel #4(Hairline). • Rear Corner Panels = Stainless Steel #4(Hairline). • Side Panels = Stainless Steel #4(Hairline). • Front Panels = Stainless Steel #4(Hairline). FALSE CEILING TYPE CD-41. FLASE CEILING FINISH Stainless Steel #4(Hairline). VENTILLATION Cross flow fan. HAND RAILS Stainless Steel Mirror Finish. Handrails on all car panels(sideLH,sideRHandRear). FLOORING Vinyl Tiles. CAR DOOR FINISH Stainless Steel #4(Hairline). LANDING DOORS FINISH Stainless Steel #4(Hairline). HOISTWAY DIMENSIONS AVAILABLE (W x D – mm) 1890 mm W x 2850 mm D. CAR DIMENSIONS (W x D x H - mm) 1100 mm W x 2000 mm D x 2200 mm D. CAR and HOISTWAY DOOR TYPE Central opening (CO) doors. DOOR OPENING (W x H - mm) 800 mm W x 2000 mm H. DOOR OPERATOR DC Door Operator.

2

-

-

... More
LIFT-`Supply Installation testing and commissioning of Passenger (1020 Kg, 15 persons.) Machine Room Less Gearless Elevator with 3 year free comprehensivie warranty period to be supplied and installed in accordance with the following technical specifications: Make:- OTIS/KONE/SHINDLER/JOHNSON/MITSUBISHI` Reference Quotation:- OTIS (Model:-GeN2-Nova MRL) `CAPACITY (kgs) 1020 Kg, 15 persons. SPEED (mps) 1 mps. RISE (m) 37 M. STOPS 9 Stops With (all opening on the same side). CONTROLLER TYPE ACD3-MRL. DRIVE VF Regenerative (Closed Loop). POWER SUPPLY 400/415 Volts (3 Phase AC). OPERATION Full collective operation. CAR GROUP One car (simplex) MACHINE PM Gearless (Located above shaft). TRACTION MEDIA Flat Coated. Steel Belt. CAR FINISH ``• Rear Mid Panel = Stainless Steel #4(Hairline). • Rear Corner Panels = Stainless Steel #4(Hairline). • Side Panels = Stainless Steel #4(Hairline). • Front Panels = Stainless Steel #4(Hairline). FALSE CEILING TYPE CD-41. FLASE CEILING FINISH Stainless Steel #4(Hairline). VENTILLATION Cross flow fan. HAND RAILS Stainless Steel Mirror Finish. Handrails on all car panels(sideLH,sideRHandRear). FLOORING Vinyl Tiles. CAR DOOR FINISH Stainless Steel #4(Hairline). LANDING DOORS (All three basement only) FINISH Stainless Steel #4(Hairline). HOISTWAY DIMENSIONS AVAILABLE (W x D – mm) 1890 mm W x 2850 mm D. CAR DIMENSIONS (W x D x H - mm) 1100 mm W x 2000 mm D x 2200 mm D. CAR and HOISTWAY DOOR TYPE Central opening (CO) doors. DOOR OPENING (W x H - mm) 800 mm W x 2000 mm H. DOOR OPERATOR DC Door Operator. Note: Provide Glass door both side Ground to Fifth floor.`

4

-

-

... More
Supply, installation, testing and commissioning of the following window based graphical software for IBMS system with 1 No. Client for Operator workstation. The Software shall have 3D and HD vector dynamic graphics with Autocad import of plan with Zoom In and Zoom Out facility, Native 64 Bit System, Multi-Monitor Support-( Max 4 Nos), Multi-language support, BTL, UL, EN Certified System, BACnet Profile B-AWS (Advanced workstation) as per the BTL Listing, dot net platform, Certified OPC DA Server by OPC Foundation, Web-Based Server software shall permit use of Standard Web-Browsers such as Microsoft Internet Explorer, Netscape Navigator, etc. The Software shall comply to international standards and strive to deliver products that meet security standards such as ISA/IEC 62443, UL2900, ISO/IEC 27001, ISO/IEC62443 and OWASP. Cybersecurity audit trail, 4-eye principle, Seamless integration of certificates within customer IT infrastructure, Microsoft’s active directory-based authentication, Use of network infrastructure that supports physical network or VLAN segmentation, Placing the web server in a “demilitarized zone” (DMZ), End-to-end encryption, from client to server, End-to-end encryption between servers, Certificate-based data exchange, Encrypted backups. The Software shall be considered for 5000 IO Points and 2 Client License (Honeywell / Siemens/ Panasonic/Inferrix/ALC)

1

-

-

... More
CSS-FIRE FIGHTING PANEL Incomer 250A, TPN MCCB 25KA - 1No. 1 No. Digital 96 sq. mm voltmeter with selector switch and 2A control MCB 1 No. Digital CT operated 96 sq. mm Ammeter with selector switch 1 Set of 3 Nos. of phase indication lamps LED type with 2A control MCB BUSBARS 300A, TPN Aluminium busbars, including making necessary connections OUTGOINGS 125A, 4P MCB 16KA with 63A 4P MCCB- 4Nos. 63A, 4P MCB 16KA with 63A 4P MCCB- 2Nos. 63A, 4P MCB 10 KA- 2No. Comon area panel as described as per above specifications grouted, installed and tested complete as required.

1

-

-

... More
CCTV_```IP Varifocal Bullet camera: Supply, Installation, Testing and Commissioning of 5MP Image Sensor 1/2.8? Progressive Scan CMOS, Min. Illumination ````Color: 0.005Lux@F1.2 Color: 0.008Lux@F1.4, B/W: 0Lux with IR on````, WDR 120dB Super WDR, Shutter Time 1/100000s~1s, IR Distance ````Up to 50m(2.7~13.5mm), Day/Night Mode, Day/Night/Auto/Customize/Schedule, S/N )55dB, Lens Motorized 2.7~13.5mm, P-Iris(Optional), Field of View ````H89°~H30°/D111°~D37°/V66°~V22° (2.7~13.5mm), Mount F14, Focus Control Auto/Manual, Iris Control (Optional for I Series) Auto/Manual, Max. Image Resolution 2592x1944, Primary Stream: 30fps@(2592x1944), Secondary Stream: 30fps@(704x576), Tertiary Stream: 30fps@(1920x1080), Video Compression H.265 plus /H.265(HEVC)/H.264 plus /H.264/MJPEG, Video Bit Rate 16Kbps~16Mbps(CBR/VBR Adjustable), Privacy Masking Up to 28 areas(24 mask areas and 4 mosaic areas), ROI Up to 8 areas, , Audio Sampling Rate: 8/16/32/44.1/48KHz, Audio Bit Rate 16~256kbps, Two-way Audio Support, Video Analysis Region Entrance, Region Exiting, Advanced Motion Detection, Tamper Detection, Line Crossing, Loitering, Object Left, Object Removed, Face Detection Detect and capture faces, get real-time snapshots, People Counting and Report, Count the number of people entering or exiting, up to 4 detection areas or regional people counting, Storage MicroSD/SDHC/SDXC Card Local Storage, up to 256G, Advanced Function Heat Map, BLC, HLC, 2D DNR, 3D DNR, Defog, AWB, EIS, IP Address Filtering, AGC, Anti-flicker, Corridor Mode, Deblur, Watermark, SIP/VoIP Support Yes, Voice and Video-over-IP, Event Trigger Motion Detection, Network Disconnection, External Input, Audio Alarm, etc. Event Action FTP Upload, SMTP Upload, SD Card Record, External Output, SIP Phone, HTTP Notification, etc. System Compatibility ONVIF Profile G and Q and S and T, API, Working Temperature -40?~60?, Working Humidity 0~90%(Non-condensing), Power Supply PoE (802.3af) / DC 12V±10%, Power Consumption 9W MAX and 13W MAX(With IR on), Housing Up to IP67-rated for Weather-resistant Performance, Certificate: BIS, FCC, CE.`` Make TYCO/AXIS/BOSCH/ GVD`

46

-

-

... More
CCTV-```IP Varifocal Dome camera: Supply, Installation, Testing and Commissioning of 5MP Image Sensor 1/2.8? Progressive Scan CMOS, Min. Illumination ````Color: 0.005Lux@F1.2 Color: 0.008Lux@F1.4 and B/W: 0Lux with IR on````, WDR 120dB Super WDR, Shutter Time 1/100000s~1s, IR Distance ````Up to 50m(2.7~13.5mm), Day/Night Mode Day/Night/Auto/Customize/Schedule, S/N )55dB, Lens ````Motorized 2.7~13.5mm, P-Iris(Optional)```` Field of View ````H100°~H32°/D125°~D40°, Mount F14, Focus Control Auto/Manual, Iris Control Auto/Manual (Optional for I Series), Max. Image Resolution 2592x1944, Primary Stream 30fps@(2592x1944) Secondary Stream: 30fps@(704x576) Tertiary Stream:30fps@(1920x1080), Video Compression H.265 plus /H.265(HEVC)/H.264 plus /H.264/MJPEG, Video Bit Rate 16Kbps~16Mbps(CBR/VBR Adjustable), Privacy Masking Up to 28 areas(24 mask areas and 4 mosaic areas), ROI Up to 8 areas, Image Setting Brightness/Contrast/Saturation/Sharpness, Ethernet 1*RJ45 10M/100M Ethernet Port, Audio I/O Built-in, Microphone and 1 Audio Output Interface, Alarm I/O 1 - 1, Network Storage NAS(Support NFS, SMB/CIFS), ANR, Protocol IPv4/IPv6, ARP, TCP, UDP, RTCP, RTP, RTSP, RTMP, HTTP, HTTPS, DNS, DDNS, DHCP, FTP, NTP, SMTP, SNMP, UPnP, Bonjour, SIP, PPPoE, VLAN, 802.1x, QoS, IGMP, ICMP, SSL, Audio Compression G.711/AAC/G.722/G.726, Two-way Audio Support, Video Analysis Region Entrance, Region Exiting, Advanced Motion Detection, Tamper Detection, Line Crossing, Loitering, Object Left, Object Removed, People Counting and Report Count the number of people entering or exiting, up to 4 detection areas or regional people counting, Support MicroSD/SDHC/SDXC Card Local Storage, up to 256G, Advanced Function Heat Map, BLC, HLC, 2D DNR, 3D DNR, Defog, AWB, EIS, IP Address Filtering, AGC, Anti-flicker, Corridor Mode, Deblur, Watermark SIP/VoIP Support Yes, Voice and Video-over-IP, Event Trigger Motion Detection, Network Disconnection, Audio Alarm, External Input, etc. Event Action FTP Upload, SMTP Upload, SD Card Record, External Output, SIP Phone, HTTP Notification, etc., System Compatibility ONVIF Profile G and Q and S and T, API, Working Temperature -40?~60?, Working Humidity 0~90%(Non-condensing), Power Supply PoE (802.3af) / DC 12V±10%, Power Consumption 8W MAX and 10W MAX (With IR on), Housing Vandal-proof IK10-rated Metal Housing / Up to IP67-rated for Weather-resistant Performance, Certificate: FCC, BIS, CE.``Make TYCO/AXIS/BOSCH/ GVD `

118

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.