National Security Guard Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

National Security Guard - NSG Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date7 Aug 2024
Closing Date19 Aug 2024
Tender Amount₹ 85,93,691 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Along external wall where the apron is not provided using chemical emulsion @75litres/ sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:

-

-

-

... More
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration

200

7780

38.9

... More
Treatment of soil under existing floors using chemical emulsion © one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement: 2 Coarse sand) to match the existing floor:

-

-

-

... More
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

100

31005

310.05

... More
Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth

-

-

-

... More
1:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)

12.46

81221

6518.6

... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

58.86

44103

749.3

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :

-

-

-

... More
1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

0.47

4251

9045.75

... More
Centering and shuttering including strutting, propping etc. and removal of form for

-

-

-

... More
Shelves (Cast in situ)

7.35

6815

927.25

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.

-

-

-

... More
Thermo-Mechanically Treated bars of grade Fe-500D or more.

47

5068

107.85

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :

-

-

-

... More
Cement mortar 1:6(1 cement : 6 coarse sand)

3

27317

9105.95

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.

-

-

-

... More
Cement mortar 1:4(1 cement :4 coarse sand)

5.4

6068

1123.8

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.

-

-

-

... More
Granite stone slab of colour black, Cherry/Ruby red

-

-

-

... More
Area of slab over 0.50 sqm

19.7

101185

5136.3

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:

-

-

-

... More
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

3.78

9044

2392.65

... More
25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws

25.2

52761

2093.7

... More
Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25 mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete:

-

-

-

... More
25 mm dia

80

42044

525.55

... More
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.

-

-

-

... More
With 12 mm mild steel U beading

50

46960

939.2

... More
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378)

-

-

-

... More
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :

-

-

-

... More
250x16 mm

37

9642

260.6

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :

-

-

-

... More
200x10 mm

74

7377

99.7

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :

-

-

-

... More
100 mm

74

4406

59.55

... More
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

111.35

63575

570.95

... More
Providing and fixing to existing door frames.

-

-

-

... More
30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/ Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856, complete as per direction of Engineer-in-charge.

38

170580

4488.95

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

900

120330

133.7

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.

-

-

-

... More
80x1.20 mm M.S. laths with 1.20 mm thick top cover

31.36

103709

3307.05

... More
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.

-

-

-

... More
Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides

20

16894

844.7

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with:

-

-

-

... More
4.0 mm thick glass panes

30

31939

1064.65

... More
Providing and laying vitrified floor tiles in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.

-

-

-

... More
Size of Tile 600x600 mm

260.75

405062

1553.45

... More
Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.

-

-

-

... More
Glazed vitrified floor tiles polished finish of size

-

-

-

... More
Size of Tile 600 x 600 mm

119

178827

1502.75

... More
Size of Tile 600 x 1200 mm

76.25

137158

1798.8

... More
Providing and laying Vitrified tiles in diferent sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).

-

-

-

... More
Size of Tile 600x600 mm

26

49241

1893.9

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
Coupler

-

-

-

... More
110 mm

10

1361

136.15

... More
Single tee with door

-

-

-

... More
110x110x110 mm

20

4683

234.15

... More
Single tee without door

-

-

-

... More
110x110x110 mm

20

4427

221.35

... More
Bend 87.5°

-

-

-

... More
110 mm bend

20

3007

150.35

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.

-

-

-

... More
110 mm

20

7426

371.3

... More
12 mm cement plaster of mix:

-

-

-

... More
1:6 (1 cement: 6 coarse sand)

200

68730

343.65

... More
15 mm cement plaster on rough side of single or half brick wall of mix:

-

-

-

... More
1:6(1 cement: 6 coarse sand)

210

83023

395.35

... More
Finishing walls with Acrylic Smooth exterior paint of required shade:

-

-

-

... More
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)

1350

216810

160.6

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour

-

-

-

... More
Old work (one or more coats)

800

50160

62.7

... More
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

1000

19750

19.75

... More
Finishing walls with Acrylic Smooth exterior paint of required shade:

-

-

-

... More
Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface

500

60375

120.75

... More
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.

-

-

-

... More
With cement mortar 1:4 (1 cement : 4 fine sand)

50

27370

547.4

... More
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:

-

-

-

... More
Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)

20

21813

1090.65

... More
Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge.

20

8675

433.75

... More
Providing & fixing White vitreous china water closet squatting pan (Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material including malba, all complete as per the direction of Engineer-in charge.

-

-

-

... More
Orissa pattern W.C Pan of size 580x440 mm

6

26872

4478.75

... More
Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.

250

862

3.45

... More
Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. (a) Internal Work- Exposed on wall

150

487

3.25

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.

-

-

-

... More
Nominal concrete 1:3:6 or richer mix (including equivalent design mix)

10

24342

2434.25

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.

2

7102

3551.25

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.

-

-

-

... More
In cement mortar

2

4120

2060.2

... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :

-

-

-

... More
Of area 3 sq. metres and below

10

3672

367.2

... More
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :

-

-

-

... More
Of area 3 sq. metres and below

35

5022

143.5

... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.

-

-

-

... More
For thickness of tiles 10 mm to 25 mm

110

8074

73.4

... More
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.

11.56

3080

266.45

... More
Demolishing mud phaska in terracing and disposal of material within 50 metres lead.

202.06

184743

914.3

... More
Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :

-

-

-

... More
100 mm dia pipe

100

7800

78

... More
Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.

35

3921

112.05

... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.

1000

54650

54.65

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :

-

-

-

... More
W.C. pan with ISI marked white solid plastic seat and lid

7

45608

6515.55

... More
Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock.

9

13955

1550.6

... More
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.

-

-

-

... More
10 litre capacity - White

6

7143

1190.65

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.

-

-

-

... More
Semi rigid pipe

-

-

-

... More
40 mm dia

20

2334

116.7

... More
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :

-

-

-

... More
Rectangular shape 453x357 mm

15

20427

1361.8

... More
Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.

10

10835

1083.5

... More
Providing and fixing toilet paper holder :

-

-

-

... More
C.P. brass

10

8037

803.7

... More
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.

10

2319

231.95

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.

-

-

-

... More
15 mm nominal dia Pipes

200

99560

497.8

... More
20 mm nominal dia Pipes

150

80640

537.6

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work

-

-

-

... More
25 mm nominal dia Pipes

100

35540

355.4

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
25 mm nominal bore

5

3112

622.4

... More
20 mm nominal bore

4

2159

539.95

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :

-

-

-

... More
20 mm nominal bore

20

9250

462.5

... More
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :

-

-

-

... More
150 mm diameter

8

1778

222.35

... More
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :

-

-

-

... More
15 mm nominal bore

10

3183

318.35

... More
20 mm nominal bore

10

3468

346.8

... More
25 mm nominal bore

4

1757

439.25

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

10000

110000

11

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :

-

-

-

... More
15 mm nominal bore

30

15204

506.8

... More
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.

-

-

-

... More
15 mm nominal bore

20

13409

670.45

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931

-

-

-

... More
15 mm nominal bore

20

11486

574.3

... More
Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge.

30

2244

74.8

... More
Providing and fixing PTMT bib cock of approved quality and colour.

-

-

-

... More
15 mm nominal bore, 86 mm long, weighing not less than 88 gms

15

1884

125.6

... More
Providing and fixing PTMT pillar cock of approved quality and colour.

-

-

-

... More
15 mm nominal bore, 107 mm long, weighing not less than 110 gms

10

2084

208.45

... More
Providing and fixing PTMT grating of approved quality and colour.

-

-

-

... More
Circular type

-

-

-

... More
125 mm nominal dia with 25 mm waste hole

20

1037

51.85

... More
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.

-

-

-

... More
15 mm nominal bore with 45 cm length

25

3047

121.9

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

12770

12770.55

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality

-

-

-

... More
L D- 2.5

-

-

-

... More
Rectangular shape 600x450 mm internal dimensions

5

7188

1437.65

... More
Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) :

-

-

-

... More
Rectangular manhole 90x80 cm with rectangular cover 600 x 450 mm of grade LD - 2.5

5

13127

2625.5

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :

-

-

-

... More
For fixed portion

-

-

-

... More
Powder coated aluminium (minimum thickness of powder coating 50 micron)

410

217669

530.9

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)

-

-

-

... More
Powder coated aluminium (minimum thickness of powder coating 50 micron)

400

253780

634.45

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):

-

-

-

... More
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)

20

30105

1505.25

... More
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.

-

-

-

... More
Upto 5 mm depth and 5 mm width

50

4837

96.75

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:

-

-

-

... More
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.

1050.61

1769857

1684.6

... More
Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 gram per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.

-

-

-

... More
With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles.

76.25

141218

1852.05

... More
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.

-

-

-

... More
Bars upto 12 mm diameter

400

3300

8.25

... More
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer- In-charge complete in all respect.

-

-

-

... More
SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer

150

21180

141.2

... More
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75 mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).

-

-

-

... More
12 mm average thickness.

300

116595

388.65

... More
Dismantling/demolishing/Removing and filling of malba/richer mix concrete/foam concrete in suken portion of toilet as per direction of Engineer-in-Charge

5

2885

577

... More
Providing and fixing Premium quality Glazed vetified wall tiles (GVT) size not less than 300x600 conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

346.59

452178

1304.65

... More
Credit for MS section like angle, tee, flats, grill etc.

150

-4200

-28

... More
Credit for SCI/CI pipe

100

-2800

-28

... More
Credit for G.I. pipe

90

-3600

-40

... More
Credit for CP fittngs etc

25

-8750

-350

... More
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white stop cock,spreader,SS tube atc and all fittings complete, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with quarter round stop cock with mannual controll system

10

82113

8211.38

... More
Removing and lifting of malba/richer mix concrete in sunken portion, lead up to 50 mtr etc all complete as per direction of EIC.

10

5534

553.41

... More
Providing and Fixing on wall face unplasticidsed Rigid PVC rain water pipes confirming to IS: 13592 Type-B,including jointing with seal ring confirming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes with 6 kg/cmxcm Pressure. 110 mm diameter

120

58560

488

... More
Electrical

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group A (AC Mess)

22

22330

1015

... More
Group C (QM Store)

4

5868

1467

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

20

31240

1562

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

210

70140

334

... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

120

64440

537

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

80

18640

233

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

48

16032

334

... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire

40

17560

439

... More
2 X 10 sq. mm + 1 X 6 sq. mm earth wire

90

51300

570

... More
4 X 4 sq. mm + 2 X 4 sq. mm earth wire

30

16110

537

... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire

20

15080

754

... More
4 X 10 sq. mm + 2 X 6 sq. mm earth wire

10

10050

1005

... More
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.

-

-

-

... More
Group A (AC Mess)

66

37884

574

... More
Group C (QM Store)

49

43806

894

... More
Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.

2

1788

894

... More
Supplying and drawing following size of FRLS PVC insulated copper conductor single core cable in the existing surface/ recessed steel/ PVC conduit as required

-

-

-

... More
1 x 1.5 sq. mm

30

1350

45

... More
2 x 1.5 sq. mm

50

3500

70

... More
3 x 1.5 sq. mm

190

18050

95

... More
4 x 1.5 sq. mm

20

2400

120

... More
5 x 1.5 sq. mm

20

3100

155

... More
6 x 1.5 sq. mm

35

6335

181

... More
9 x 1.5 sq. mm

10

2850

285

... More
1 x 4 sq. mm

20

1760

88

... More
3 x 4 sq. mm

140

28840

206

... More
6 x 4 sq. mm

30

11880

396

... More
3 x 6 sq. mm

20

6080

304

... More
2 x 10 sq. mm + 1 x 6 Sq.mm

42

19278

459

... More
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required

-

-

-

... More
1 Pair

10

310

31

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

80

3760

47

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20 mm

46

5888

128

... More
25 mm

62

8990

145

10

1840

184

10

2280

228

15

4260

284

... More
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.

-

-

-

... More
5/6 A switch

10

520

52

... More
2 way 5/6 A switch

2

128

64

... More
15/16 A switch

5

605

121

... More
3 pin 5/6 A socket outlet

10

690

69

... More
6 pin 15/16 A socket outlet

5

685

137

... More
Telephone socket outlet

2

218

109

... More
TV antenna socket outlet

2

190

95

... More
Bell push

2

166

83

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
5/6 A switch

115

11845

103

... More
2 way 5/6 A switch

2

296

148

... More
15/16 A switch

30

4680

156

... More
3 pin 5/6 A socket outlet

20

2440

122

... More
6 pin 15/16 A socket outlet

42

8274

197

... More
Telephone socket outlet

10

1480

148

... More
TV antenna socket outlet

10

1480

148

... More
Bell push

10

1400

140

... More
6 A to 32 A rating, 240 V, , "C" curve, SP modular MCB

5

1510

302

... More
25 amp switch

5

1485

297

... More
Computer Jack ( RJ 45) Cat6 (1 module)

10

3000

300

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

55

20295

369

... More
Supplying and fixing two module stepped type electronic piano fan regulator on the existing phenolic cover plate switch box including connections but excluding cover plate etc. as required.

5

1710

342

... More
Supplying and fixing one module stepped type electronic piano fan regulator on the existing phenolic cover plate switch box including connections but excluding cover plate etc. as required.

5

1560

312

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

52

2080

40

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.

-

-

-

... More
1 or 2 Module (75mmX75mm)

6

1788

298

... More
3 Module (100mmX75mm)

1

327

327

... More
4 Module (125mmX75mm

14

4802

343

... More
6 Module (200mmX75mm)

4

1608

402

... More
8 Module (125mmX125mm)

4

1816

454

... More
12 Module (200mmX150mm)

12

6564

547

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.

10

4770

477

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

39

22854

586

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.

20

1740

87

... More
Installation, testing, commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/ CFL / LED lamps per fitting/ /Downlighters/ LED Panel Light /LED batten on wall or ceiling, complete with all accessories including connection and earthing etc. as required.

5

595

119

... More
Supplying and fixing Ding Dong Door Bell, suitable for single phase, 230 V, complete as required.

1

99

99

... More
Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required.

10

400

40

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq, mm FRLS PVC insulated, copper conductor, single core cable etc. as required.

2

426

213

... More
Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

1

46

46

... More
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

1

52

52

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.

-

-

-

... More
Upto 450 mm sweep

1

450

450

... More
510 mm sweep

1

643

643

... More
Extra for fixing the louvers/ shutters complete with frame for an exhaust fan of all sizes.

1

207

207

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.

-

-

-

... More
1 run of cable

10

570

57

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group C

5

4290

858

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required.

29

19720

680

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 16 amp modular socket outlet and 16 A /25 A modular SP MCB, "C" curve including connection, painting etc. as required.

30

23730

791

... More
Supplying and fixing PVC batten/ angle holder including connections etc. as required.

15

1650

110

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
6 way , Double door

1

2206

2206

... More
8 way , Double door

1

2573

2573

... More
12 way , Double door

3

6945

2315

... More
16 way, Double door

6

18846

3141

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

94

24064

256

... More
Double pole

1

656

656

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

2

26

13

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

2

5284

2642

9

24498

2722

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

1

2872

2872

... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

1

1169

1169

... More
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.

1

1592

1592

... More
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.

-

-

-

... More
For 6 way, Double door SPN MCBDB

1

752

752

... More
For 8 way, Double door SPN MCBDB

1

832

832

... More
For 10 way/ 12 way, Double door SPN MCBDB

3

2430

810

... More
For 14 way/16 way, Double door SPN MCBDB

6

5412

902

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

5

4815

963

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

5

9260

1852

... More
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

6

41130

6855

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required.

60

17220

287

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

120

5040

42

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclo sure with cover plate having locking arrangement and wa tering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

2

14944

7472

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

12

8472

706

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

5

1220

244

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, down rod upto 30 cm long , 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 8, Air delivery minimum 215 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, without remote and compatible with existing step electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (BLDC Ceiling fan with minimum 2 year Warranty )

55

190575

3465

... More
Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe and making good the same etc. complete as per direction of Engineer-in-charge.

2

1530

765

... More
Supplying and fixing two module Buzzer on the existing modular plate switch box including connections but excluding modular plate etc. as required.

2

672

336

... More
Supplying and fixing two module bell/ chime on the existing modular plate switch box including connections but excluding modular plate etc. as required.

2

1046

523

... More
Supplying & Fixing of 2 to 4 watt LED wall light as bed light etc required as per direction of engg-in-charge. Make : Havells/ phillips / Wipro/ Jaquar)

1

1320

1320

... More
Supply, installation, testing and commissioning of wall-mounted light fixture complete with B22 base, metal base in Nickel / Brass finishing with diffuser and 9 watts LED blub etc., as required directly on the wall, including connections etc. as required. ( Havells /Wipro/Philips/Jaquar)

10

12870

1287

... More
Supply, Installation, Testing and Commissioning of 900 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, down rod upto 30 cm long , 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6, Air delivery minimum 170 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, without remote and compatible with existing step electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (BLDC Ceiling fan with minimum 2 year Warranty)

1

3314

3314

... More
Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 7.00, Air delivery minimum 250 Cum/Min, 250 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (BLDC Ceiling fan with minimum 2 year Warranty )

1

3684

3684

... More
Supply and installation of 400 mm sweep, 220 V, wall mounted fan along with speed regulator unit for speed control, on the existing wall, including connection, testing, commissioning etc. as required. (Make: Crompton/Havells/Orient/Usha/Bajaj/Almonard)

1

3209

3209

... More
Supplying and fixing 3 mm thick phenolic laminated sheet cover on existing switch Box / metal box with Al. Alloy/ cadmium/ zinc plated screws and washers, including cutting the laminated sheet to required shape and size etc., complete as required.

1

4285

4285

... More
Supplying and installation of PVC Exhaust fan with louver shutter 150 mm sweep in the existing opening including making the hole to suit the size of the above fan and making good the damage, connection, testing , commissioning etc as required. (Havells / C&G / Orient / Usha / Almonard)

10

21530

2153

... More
Supplying and installation of PVC Exhaust fan with louver shutter 200 mm sweep in the existing opening including making the hole to suit the size of the above fan and making good the damage, connection, testing , commissioning etc as required. (Havells / C&G / Orient / Usha / Almonard)

1

2345

2345

... More
Supplying and installation of PVC Exhaust fan with louver shutter 250 mm sweep in the existing opening including making the hole to suit the size of the above fan and making good the damage, connection, testing , commissioning etc as required. (Havells / C&G / Orient / Usha / Almonard/ Atomberg)

12

30000

2500

... More
Supplying and installation of 300 mm sweep, 1400 RPM heavy-duty, single phase, metallic exhaust fan Conforming to IS:2312 -1967 in the existing opening, including making the hole to suit the size of the above fan and making good the damage, connection, testing, commissioning etc. as required. (Havells Turbo force Heavy Duty Exhaust Fan or with similar specifications C&G / Orient / Usha / Almonard)

2

10422

5211

... More
Supplying and installation of 450 mm sweep, 1400 RPM heavy-duty, single phase, metallic exhaust fan Conforming to IS:2312 -1967 in the existing opening,including making the hole to suit the size of the above fan and making good the damage, connection, testing, commissioning etc. as required. (Havells Turbo force Heavy Duty Exhaust Fan or with similar specifications C&G / Orient / Usha / Almonard)

1

8493

8493

... More
Supplying and installation of 225/ 230 mm sweep, single phase, metallic exhaust fan in the existing opening,including making the hole to suit the size of the above fan and making good the damage, connection, testing, commissioning etc. as required. (Havells Ventil Air or with similar specifications C&G / Orient / Usha / Almonard)

1

2348

2348

... More
Making holes of the required size and shape in a brick masonry wall for installation of the following size exhaust fan, including making good the wall by plastering and finishing with the matching surface, etc., complete as per the direction of the engineer-in-charge.

-

-

-

... More
150 mm sweep.

1

93

93

... More
200 mm sweep.

1

140

140

... More
250 mm sweep.

1

197

197

... More
450 mm sweep.

1

516

516

... More
225 mm /230 mm sweep

1

142

142

... More
Cutting a hole of the required size and shape on the window or ventilator glass pane for the installation of an exhaust fan of size up to 150 mm sweep, etc., complete as per the direction of the engineer-in-charge.

1

122

122

... More
Supply and fixing of 8 mm thick BWP/marine grade plywood wood board having a circular /rectangular hole to suit the sie of exhaust fan upto 380 mm on wall /window for etc as required including the cost of making hole, nuts and bolts, etc. as required.

1

643

643

... More
Supplying and fixing suitable size GI box in recess, including providing and fixing of 2/3 Module LED Foot light / skirting light, including connection etc. as required.

1

905

905

... More
Supply, installation, testing, and commissioning of integrated LED Batten luminaire, 1100 mm (nominal size) with a minimum system lumen output of 4800 lumen and with a minimum system luminous efficacy of 120 lm/W, made of aluminium housing having a colour temperature 5500K - 6500 K, Average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required.

2

2922

1461

... More
Supply, installation, testing, and commissioning of integrated LED Batten luminaire, 1100 mm (nominal size) with a minimum system lumen output of 2400 lumen and with a minimum system luminous efficacy of 120 lm/W, made of aluminium housing having a colour temperature 5500K - 6500 K, Average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required.

31

27342

882

... More
Supply, installation, testing, and commissioning of integrated LED Batten luminaire, 600 mm (nominal size) with a minimum system lumen output of 1000 lumen and with a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature 5500K - 6500 K, Average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required.

5

3200

640

... More
Supply, installation, testing, and commissioning of LED bulkhead fittings with IP 66 ingress protection, with a minimum system lumen output of 1000 lumens and a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature of 5500K–6500 K, average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser, electronic driver, etc. as required directly on the wall, including connections, etc. as required.

7

12012

1716

... More
Supply, installation, testing and commissioning of surface mounted LED downlighter luminaire in metallic housing, with a minimum system lumen output of 1500 lumen and with a minimum system luminous efficacy of 100 lm/W, Average LED life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser and electronic driver, directly on ceiling, including connections and earthing etc. as required.

22

55022

2501

... More
Supply, installation, testing, and commissioning of 2 ft. x 2 ft. (nominal size) LED Surface Mounted LED Panel Light, in metallic housing, with a minimum system lumen output of 3960 lumens and a minimum system luminous efficacy of 110 lm/W, colour temperature of 5500K–6500K, average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling, including connections, earthing, etc. as required.

22

98120

4460

... More
Supply, installation, testing, and commissioning of 2 ft. x 2 ft. (nominal size) LED recessed Mounted LED Panel Light, in metallic housing, with a minimum system lumen output of 3960 lumens and a minimum system luminous efficacy of 110 lm/W, colour temperature of 5500K–6500K, average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, suitable for recessed mounting, Armstrong/grid/POP/GB ceiling complete with all accessories, diffuser and electronic driver, directly on the ceiling, including connections and earthing etc. as required.

2

7334

3667

... More
Supplying and fixing Plastic Batten/Angle holder alonwith 9/10 watt LED blub including connection etc. as required.

10

2730

273

... More
Providing and fixing a metallic louvred shutter suitable for following sizes exhaust fan, the louvres should be able to open when the fan is on and close when the fan is turned off, on the existing opening on the wall, etc., as required.

-

-

-

... More
300 mm

2

1664

832

... More
380 mm

2

2124

1062

... More
450 mm

2

2736

1368

... More
Providing and fixing 3 mm thick PVC/ phenolic laminated round sheet cover with a minimum of 170 mm dia on the existing fan box with two screws, etc., as required.

55

1705

31

... More
Providing and fixing 3 mm thick PVC / phenolic laminated round sheet cover on the existing junction box with two screws, etc., as required.

120

1320

11

... More
Supply, installation, testing, and commissioning of outdoor type 3-watt IP 65 LED foot light/ step light in Die cast aluminium housing and Polycarbonate diffuser, complete with connection, etc., as required. (Jaquar LFTL01S003XW or similar in Philips / Wipro /LT/ Havells)

2

1520

760

... More
Supplying and fixing following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required

-

-

-

... More
40 A Double pole

2

2494

1247

... More
63 A Double pole

5

6235

1247

... More
Supplying and fixing following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
40 A Triple pole and neutral

1

2388

2388

... More
63 A Triple pole and neutral

1

2388

2388

... More
Fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
6 to 16 way, Double door

1

522

522

... More
Fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

1

97

97

... More
Single pole and neutral

1

97

97

... More
Double pole

1

97

97

... More
Triple pole

1

97

97

... More
Triple pole and neutral

1

97

97

... More
Supplying and fixing of following size PVC Saddles with base and screws on existing PVC / steel conduit etc as reqd (Precision / AKG /Polycab /Finolex / Anchor/ GM) i) 20 mm

15

240

16

... More
Supplying and fixing of following size PVC Saddles with base and screws on existing PVC / steel conduit etc as reqd (Precision / AKG /Polycab /Finolex / Anchor/ GM) i) 25 mm

10

170

17

... More
Supplying and fixing of 23 mm x 1.5 mm S.S./G.I. saddles on the following sizes of existing PVC or steel conduit, cable, pipe, etc., as required (Astral, Prayag, Ashirvad, Finolex, or as approved by the engineer-in-charge) i) 50 mm

10

390

39

... More
Rewinding of following size ceiling fan / Wall fan motor including complete removal of existing burnt out winding and rewinding of the fan with suitable size enameled copper wire, including sleeving, suitable insulation materials, varnishing etc., complete with dismantling and reassembling after repair, including connection testing etc. as required. Removed winding wire shall be retained by the contractor and suitably credited with its value and net value to be quoted.

-

-

-

... More
1200mm Sweep ceiling fan

20

10500

525

... More
1400mm Sweep ceiling fan

2

1094

547

... More
Wall Fan upto 400 mm

2

1086

543

... More
Rewinding of stator winding of following size exhaust fans with suitable size enameled copper wire (as per manufacturer specification) including slaving of stator suitable insulation materials ie “E” class varnish complete with dismantling and reassembling after repair i/c connection testing etc as required (Brunt copper wire will be retained by the contractor).

-

-

-

... More
300mm / 380 mm exhaust fan

2

1528

764

... More
450 mm exhaust fan

2

2030

1015

... More
600mm exhaust fan

2

3330

1665

... More
Providing and replacing ball bearing in following size ceiling fan/exhaust fan, including removing old ball-bearing, installing new ball bearing and testing the fan, etc., as required. (Scrap material will be retained by the contractor). (Both side shield ball bearing of SKF/ NBC /TATA )

-

-

-

... More
1200mm Sweep ceiling fan.

40

6960

174

... More
1400mm Sweep ceiling fan.

4

696

174

... More
300mm/ 380 mm exhaust fan

4

696

174

... More
450 mm exhaust fan.

4

752

188

... More
600 mm exhaust fan.

4

752

188

... More
Providing and replacing 2.5 MFD fan capacitor in the ceiling fan/exhaust fan/wall fan, including connection and testing, etc., as required. (The old capacitor will be retained by the contractor).

20

920

46

... More
Providing and replacing the 4 MFD fan capacitor in the ceiling fan/exhaust fan/wall fan, including connection and testing, etc., as required. (The old capacitor will be retained by the contractor).

2

106

53

... More
Reconditioning of the oversized bush bearing housing to a suitable ball bearing in the ceiling fan/ exhaust fan/ wall-mounted fans as required and assembling and testing of the fan after repair. All the scrap material should be retained by the contractor.

10

1660

166

... More
Providing and replacing the worn-out M.S. shaft of the exhaust fan /wall fan with a suitable size new shaft etc., as required, including removing the old shaft, installing the new shaft, and testing the fan. All the scrap material should be retained by the contractor.

10

1590

159

... More
Supplying, installation testing and commissioning of BEE 5 star rating, 25 litres capacity water storage heater, with protection against over heating, Multifunction Safety Valve and external adjustable thermostat, with 16 A, 240 V, plug top and 02 nos flexible connection pipe suitable for working with 230V AC, 50 Hz, 1 Phase supply etc as required. (Make: Havells / Crompton/ AO Smith /Racold /Jaguar with 7 year warranty on inner tank, 3 year warranty on heating element, 2 year comprehensive Warranty)

1

11441

11441

... More
Supplying, installation testing and commissioning of BEE 5 star rating, 15 litres capacity water storage heater, with protection against over heating, Multifunction Safety Valve and external adjustable thermostat, with 16 A, 240 V, plug top and 02 nos flexible connection pipe suitable for working with 230V AC, 50 Hz, 1 Phase supply etc as required. (Make: Havells / Crompton/ AO Smith /Racold /Jaguar with 7 year warranty on inner tank, 3 year warranty on heating element, 2 year comprehensive Warranty)

1

10032

10032

... More
Supplying and fixing PRCD (Portable Residual Current Device) Plug top, 16 A 30 mA rating including connection etc. as required.

1

798

798

... More
Supplying and fixing suitable size GI/ PVC box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 6 pin 15/16 A modular socket outlet and 2 nos. 151/6 A modular switch, connections etc. as required.

29

28884

996

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray with 1.6 mm G.I. sheet cover, in convenient sections, joined with connectors, suspended/fixed from the ceiling / wall /floor with G.I. suspenders/ G.I. angle iron brackets including G.I. bolts & nuts, etc. as required including G.I. bolts & nuts, etc. as required

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

10

6080

608

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Bends" with 1.6 mm G.I. sheet cover, in convenient sections, joined with connectors, suspended/fixed from the ceiling / wall /floor with G.I. suspenders/ G.I. angle iron brackets including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

5

7405

1481

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee " with 1.6 mm G.I. sheet cover, in convenient sections, joined with connectors, suspended/fixed from the ceiling / wall /floor with G.I. suspenders/ G.I. angle iron brackets including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

5

7605

1521

... More
Dismantling of the existing switch accessories like switches, sockets, and MCBs, etc., as required.

20

80

4

... More
Dismantling of the existing ceiling rose, holder, and wall bracket and depositing the same with the listing of materials in the store.

10

90

9

... More
Dismantling of existing fluorescent fitting from ceiling/ wall including making good the damage to match the adjacent surface, etc., as required.

40

960

24

... More
Dismantling of the existing ceiling fan/ exhaust fan of any size installed in the building and depositing it in the MMC store.

55

3300

60

... More
Dismantling of the existing recessed vertical type or horizontal type TPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required.

2

442

221

... More
Dismantling of the existing recessed SPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required.

5

840

168

... More
Dismantling of the existing recessed switch board of light points/power points, power/light plug points/socket outlet metal boxes of any size, along with phenolic laminated sheet, switches, sockets, etc., making good the damage to match the adjacent surface, etc., as required.

20

1420

71

... More
Supplying and fixing Plug top following rating including connection etc. as required.

-

-

-

... More
16 A, three pin, Plug top ISI marked

5

635

127

... More
6 A, three pin, Plug top ISI marked

5

515

103

... More
Supplying and fixing Bakelite Sheet of following size with screw in the existing looping box/ panel including cutting the sheet to required shape and size complete etc as reqd.

-

-

-

... More
6 mm thick

0.25

1098

4393

... More
Supplying and fixing 25 A modular SP MCB, "C" curve on the existing modular plate switch box including connections but excluding modular plate etc. as required.

2

604

302

... More
Supplying and laying of G.I. pipe of 50 mm dia.(nominal), medium class, ISI marked in wall / floor including cutting chase, and making good the wall/ floor and finishing with matching surface after housing G.I. pipe in chase. ( for protection of UG cable)

6

5016

836

... More
Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it. Above 25 mm conduits.

20

140

7

... More
Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it. Up to 25 mm conduit.

42

148

3.53

... More
Supplying, installation, testing and commissioning of 2 Ton, Hot and Cold Inverter type, Wall Mounted Split type Air conditioner complete suitable for operation on 230 V, 50 Hz single phase AC supply, with all standard accessories ( Indoor Unit, Outdoor Unit, Inter-connecting kit with copper pipe wrapped with insulation, Drain pipe and connecting cable, copper Condenser and Evaporator Coil, remote control, user manual with warranty certificate as per OEM specifications). i) Connecting copper pipes and cable length 3 mtrs. ii)Warranty : minimum 1 Year on complete Unit, PCB warranty 5 Years and 10 Years on Compressor. iii) Cooling at 100% capacity : 7000 Watt minimum. iv) Heating at 100% capacity : 7000 Watt minimum v) Rated ISEER : minimum 4.5 vi) The AC should be designed to work at a maximum operating ambient temperature of up to 52 degrees Celsius (outdoor temperature).

6

543582

90597

... More
Supplying and fixing of wall/ Floor mounted bracket suitable for 1.5/ 2 ton split Air conditioner outdoor unit etc. complete as required.

6

5820

970

... More
Providing and fixing of extra refrigerant copper piping with insulation and cable for 1.5 ton/2 ton Split AC as per manufacturers specification , clamps, etc. complete as reqd. ( two copper pipes one suction and one discharge line with connecting cable and foam insulation tubing will be measured as one unit) .

18

16074

893

... More
Providing and fixing CPVC pipe 20 mm dia with all accessories e.g. elbows, unions, sockets, reducers, reducing tees, nipples etc., including fixing the pipe with clamps at 1.00 m spacing on wall / floor etc. as required. (Ashirwad /Astral /Finolex/ Supreme/ Prayag )

20

3780

189

... More
Providing and fixing 1/2 inches dia nylon braided flexible drain pipe for split/cassettee air conditioners etc. as required.

20

1360

68

... More
Dismatling of existing of 1.5 ton /2.0 ton split air conditioner with indoor unit, out door unit and copper piping etc complete as reqd.

10

8060

806

... More
Supplying and installing the following size PVC trunking cable management system, complete with front cover, internal/external/flat angles, joints, junctions, end caps, and finishing accessories, etc. as required. (Make-Legrand/ Honeywell / OBO Beterman)

-

-

-

... More
100 x 50 mm

6

9522

1587

... More
32 X 12.5 mm

40

12720

318

... More
Supplying and fixing of the following sizes of PVC-insulated FRLS-sheathed round copper conductor multi-core cable, including connections, testing, etc., for air conditioners as required. (Havells/Polucab/RR Kable/Finolex )

-

-

-

... More
3x 2.5 sqmm

20

3080

154

... More
4x 2.5 sqmm

20

4000

200

... More
Supplying and fixing of following sizes module frame on existing trunking etc. as required. (Make-Legrand/ Honeywell / OBO Beterman)

-

-

-

... More
1-3 Module Frame

6

1230

205

... More
4-5 Module Frame

2

492

246

... More
8 Module Frame

2

798

399

... More
Less cost index difference of electrical DSR items 2022 @ (-) 2.73% on Rs. 869128/-

1

-23727

-23727.19

... More
Add 1.0633 multiplying factor for GST on DSR (On electrical items) on Rs. 8,45,400.81

1

53513

53513.87



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.