National Security Guard Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

National Security Guard - NSG Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date3 Sep 2024
Closing Date12 Sep 2024
Tender Amount₹ 2,94,98,949 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Get the Best Price For TMT
Starting from
₹47,511/MT*
Haryana

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Chlorpyriphos/ Lindane emulsifiable concentrate of 20%

150

35212

234.75

... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :

-

-

-

... More
Along external wall where the apron is not provided using chemical emulsion @75litres/ sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:

-

-

-

... More
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration

150

5835

38.9

... More
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:

-

-

-

... More
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration

125

6681

53.45

... More
Treatment of soil under existing floors using chemical emulsion © one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement: 2 Coarse sand) to match the existing floor:

-

-

-

... More
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

125

38756

310.05

... More
Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole :

-

-

-

... More
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

120

5160

43

... More
Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same.

100

27970

279.7

... More
Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth

-

-

-

... More
1:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)

17.41

113488

6518.6

... More
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 12.5 mm nominal size derived from natural sources)

12.5

5135

410.85

... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

241.2

180731

749.3

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :

-

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:

-

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

113.4

44469

392.15

... More
Shelves (Cast in situ)

95.35

88413

927.25

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

90.49

66636

736.4

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

10

9613

961.3

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.

-

-

-

... More
Thermo-Mechanically Treated bars of grade Fe-500D or more.

3255

351051

107.85

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.

-

-

-

... More
Thermo-Mechanically Treated bars of grade Fe-500D or more.

4701

507002

107.85

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
All works upto plinth level

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum

21.7

206253

9504.75

... More
All works above plinth level upto floor V level

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum

31.34

309024

9860.4

... More
Add for using extra cement in the items of design mix over and above the specified cement content therein.

16

11736

733.5

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:

-

-

-

... More
Cement mortar 1:6(1 cement :6 coarse sand)

12.37

88225

7132.25

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :

-

-

-

... More
Cement mortar 1:6(1 cement : 6 coarse sand)

40.78

371340

9105.95

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :

-

-

-

... More
cement mortar 1:4(1 cement :4 coarse sand)

7.16

6480

905.05

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.

-

-

-

... More
Cement mortar 1:4(1 cement :4 coarse sand)

5

5619

1123.8

... More
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).

259.6

15796

60.85

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.

-

-

-

... More
Granite stone slab of colour black, Cherry/Ruby red

-

-

-

... More
Area of slab upto 0.50 sqnn

118.41

641012

5413.5

... More
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

80

101436

1267.95

... More
Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25 mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete:

-

-

-

... More
25 mm dia

150

78832

525.55

... More
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :

-

-

-

... More
300x16 mm

10

3032

303.25

... More
250x16 mm

5

1303

260.6

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :

-

-

-

... More
250x10 mm

20

2303

115.15

... More
200x10 mm

10

997

99.7

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :

-

-

-

... More
125 mm

20

1325

66.25

... More
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.

-

-

-

... More
Twin rubber stopper

10

723

72.35

... More
Providing and fixing to existing door frames.

-

-

-

... More
Providing and fixing factory made Fiberglass Reinforced plastics (F.R.P.) chajja 4 mm thick of required colour, size and design made by Resin Transfer Moulding (RTM) Machine Technology, resulting in void free compact laminate in single piece, having smooth gradual slope curvature for easy drainage of water and duly reinforced by 2 nos vertically and 1 nos horizontally 50x2 mm thick M.S. flat with 12 mm in built hole for grouting on the existing wall along with the 50 mm flanges duly inserted and sealed in the wall complete in one single piece casted monolithically, including all necessary fittings . The FRP Chajja should be manufactured using unsaturated Polyester resin as per IS: 6746, duly reinforced with fibre glass chopped strand mat (CSM) as per IS: 11551 complete with protective Gel coat U/V coating on Top for complete resistance from the extreme of temperature, weather & sunlight (Only plan area of chajjas shall be measured for making payment).

49.5

257768

5207.45

... More
Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds

-

-

-

... More
Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.

-

-

-

... More
Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m).

185.04

2012161

10874.2

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

500

66850

133.7

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.

-

-

-

... More
Hot finished welded type tubes

300

58320

194.4

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :

-

-

-

... More
25 mm thick

400.21

779709

1948.25

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

45

105961

2354.7

... More
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.

-

-

-

... More
Size of Tile 1000x1000 mm

570

99465

174.5

... More
Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.30 kg / sqm including grouting the joints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only. Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. Size of tile 800x2400 mm of all colours and shades.

648.45

2349950

3623.95

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
Coupler

-

-

-

... More
110 mm

5

680

136.15

... More
Single pushfit Coupler

-

-

-

... More
110 mm

5

638

127.6

... More
Single tee with door

-

-

-

... More
110x110x110 mm

5

1170

234.15

... More
Single tee without door

-

-

-

... More
110x110x110 mm

5

1106

221.35

... More
Bend 87.5°

-

-

-

... More
110 mm bend

5

751

150.35

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.

-

-

-

... More
110 mm

5

1856

371.3

... More
15 mm cement plaster on rough side of single or half brick wall of mix:

-

-

-

... More
1:6(1 cement: 6 coarse sand)

1651.2

652801

395.35

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour:

-

-

-

... More
New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre

2000

371300

185.65

... More
Finishing walls with Acrylic Smooth exterior paint of required shade:

-

-

-

... More
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)

5000

803000

160.6

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :

-

-

-

... More
Two or more coats on new work

150

23385

155.9

... More
Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete.

500

234450

468.9

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

2500

390125

156.05

... More
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

1500

29625

19.75

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:

-

-

-

... More
One or more coats on old work

150

15420

102.8

... More
Finishing walls with Acrylic Smooth exterior paint of required shade:

-

-

-

... More
Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface

200

24150

120.75

... More
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.

-

-

-

... More
With cement mortar 1:4 (1cement: 4 coarse sand)

100

56050

560.5

... More
Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge.

20

8675

433.75

... More
Providing & fixing White vitreous china water closet squatting pan (Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material including malba, all complete as per the direction of Engineer-in charge.

-

-

-

... More
Orissa pattern W.C Pan of size 580x440 mm

2

8957

4478.75

... More
Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.

570

1966

3.45

... More
Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. (a) Internal Work- Exposed on wall

50

162

3.25

... More
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.

10

4291

429.1

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.

-

-

-

... More
Nominal concrete 1:3:6 or richer mix (including equivalent design mix)

5

12171

2434.25

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.

2

7102

3551.25

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.

-

-

-

... More
In cement mortar

2

4120

2060.2

... More
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :

-

-

-

... More
Of area 3 sq. metres and below

100

14350

143.5

... More
Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in:

-

-

-

... More
Channels, angles, tees and flats

500

1150

2.3

... More
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.

800

4520

5.65

... More
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.

50

13322

266.45

... More
Demolishing mud phaska in terracing and disposal of material within 50 metres lead.

306.4

280141

914.3

... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.

1500

81975

54.65

... More
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer- in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.

-

-

-

... More
Cement concrete manufactured in automatic batching plant (RMC plant) including transportation to site in transit mixer

43.56

483448

11098.45

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :

-

-

-

... More
W.C. pan with ISI marked white solid plastic seat and lid

2

13031

6515.55

... More
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :

-

-

-

... More
Single half stall urinal with 5 litre P.V.C. automatic flushing cistern

1

12071

12071.75

... More
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.

-

-

-

... More
10 litre capacity - White

2

2381

1190.65

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.

-

-

-

... More
Semi rigid pipe

-

-

-

... More
40 mm dia

5

583

116.7

... More
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :

-

-

-

... More
Rectangular shape 453x357 mm

2

2723

1361.8

... More
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.

2

463

231.95

... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.

-

-

-

... More
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.

2

1417

708.95

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall

-

-

-

... More
15 mm nominal dia Pipes

10

2868

286.8

... More
20 mm nominal dia Pipes

10

3350

335

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work

-

-

-

... More
20 mm nominal dia Pipes

20

5486

274.3

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall

-

-

-

... More
15 mm dia nominal bore

30

10992

366.4

... More
20 mm dia nominal bore

70

30611

437.3

... More
25 mm dia nominal bore

100

55170

551.7

... More
50 mm dia nominal bore

50

52417

1048.35

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work

-

-

-

... More
40 mm dia nominal bore

50

30852

617.05

... More
50 mm dia nominal bore

50

38107

762.15

... More
65 mm dia nominal bore

50

44830

896.6

... More
Providing and fixing uplasticised PVC connection pipe with brass unions :

-

-

-

... More
45 cm length

-

-

-

... More
15 mm nominal bore

10

977

97.75

... More
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :

-

-

-

... More
150 mm diameter

2

444

222.35

... More
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :

-

-

-

... More
25 mm nominal bore

5

2196

439.25

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

12000

132000

11

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :

-

-

-

... More
15 mm nominal bore

10

5068

506.8

... More
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.

-

-

-

... More
15 mm nominal bore

5

3352

670.45

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931

-

-

-

... More
15 mm nominal bore

5

2871

574.3

... More
Providing and fixing PTMT grating of approved quality and colour.

-

-

-

... More
Circular type

-

-

-

... More
125 mm nominal dia with 25 mm waste hole

5

259

51.85

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

12770

12770.55

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality

-

-

-

... More
L D- 2.5

-

-

-

... More
Rectangular shape 600x450 mm internal dimensions

1

1437

1437.65

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :

-

-

-

... More
For fixed portion

-

-

-

... More
Powder coated aluminium (minimum thickness of powder coating 50 micron)

200

106180

530.9

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)

-

-

-

... More
Powder coated aluminium (minimum thickness of powder coating 50 micron)

200

126890

634.45

... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.

-

-

-

... More
Pre-laminated particle board with decorative lamination on both sides

10

11154

1115.4

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):

-

-

-

... More
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)

10

15052

1505.25

... More
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.

-

-

-

... More
Upto 5 mm depth and 5 mm width

50

4837

96.75

... More
Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately).

250

100700

402.8

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:

-

-

-

... More
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.

1922.18

3238104

1684.6

... More
Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 gram per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.

-

-

-

... More
With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles.

294.93

546225

1852.05

... More
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.

-

-

-

... More
Frame size 65 x 100 mm

50

55565

1111.3

... More
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)

-

-

-

... More
30 mm thick

11.55

55026

4764.2

... More
35 mm thick

20.79

112948

5432.85

... More
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/ kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately)

-

-

-

... More
25 mm thick

25.2

98006

3889.15

... More
Credit for MS section like angle, tee, flats, grill etc.

250

-9750

-39

... More
Credit for SCI/CI pipe

200

-7000

-35

... More
Credit for G.I. pipe

50

-1750

-35

... More
Credit for CP fittngs etc

50

-24200

-484

... More
Providing and Fixing Glass shelf 600 mm long of JAQUAR make cat No. ACN-CHR-1171N or Euronics make cat. No. ACC06 or equivalent as per direction of Engineer-in-charge.

2

4706

2353

... More
Providing and laying rectified matt finish Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make in all colours, shades and pattern matching with bathroom wall tile concepts, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.

20

28520

1426

... More
Providing and Fixing on wall face unplasticidsed Rigid PVC rain water pipes confirming to IS: 13592 Type-B,including jointing with seal ring confirming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes with 6 kg/cmxcm Pressure. 110 mm diameter

35

16835

481

... More
15mm cement plaster on external wall surface of single or half brick wall of polymer modified ready mixed plaster of fine grade Portland, graded sand polymers with water soluble additives as per manufacturer specification of approved make and as per directions of Engineer- in charge.

616

343728

558

... More
Providing and fixing 6mm thick High Pressure (interior grade) compact Laminate made out of thermosetting resign treated Kraft as core material and design paper as a finish surface.Compact laminates should have the characteristic of flame retardant fulfilled the crite- ria of under BS-476/97 and EN438-6 with classification of BS1D0 standard property,Anti bacterial and anti-termite property under JIS Z2801:2000,Chemical resistance, Scratch resistant fire re- sistance,weather & climatic shock resistance(The manufacturer should provide10 years warranty certification on any manufactur- ing and moisture related defects)The compact laminates should be resistance to water immersion through permissible increase on thickness and mass 0.60parcent and board should have densi- ty1.35kg/cm3 and fulfilled the criteria of FSCand Green Guard Gold certification and manufactured under EN438-2&3:2005 standard Finish and colour of compact laminates should be final- ised under direction of Engineer –incharge.including fixing Com- pact laminates on existing 25x50 mmx2mm thick aluminium tube or approved tube size at 600mm c/c under desirable height and fixed through same compact colour rievts or compact adhesive as per recommended by compact supplied agency Finish and colour of Interior cladding should be approved under engineer-in-charge direction.

81.9

347829

4247

... More
Deduct GST Factor on DSR-2023 Items @ total of DSR rates - 0.973 of DSR rates) i.e 1,75,67,289.40 x 0.973 = Rs. 1,70,92,972.59 (C)

1

-474316

-474316.81

... More
Electrical

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group A

4

4060

1015

... More
Group B

4

4728

1182

... More
Group C

109

159903

1467

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

10

15620

1562

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

875

292250

334

... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

458

245946

537

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

310

72230

233

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

435

145290

334

... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire

160

70240

439

... More
2 X 10 sq. mm + 1 X 6 sq. mm earth wire

180

102600

570

... More
2 X 16 sq. mm + 1 X 6 sq. mm earth wire

120

92640

772

... More
4 X 4 sq. mm + 2 X 4 sq. mm earth wire

220

118140

537

... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire

80

60320

754

... More
4 X 10 sq. mm + 2 X 6 sq. mm earth wire

95

95475

1005

... More
4 X 16 sq. mm + 2 X 6 sq. mm earth wire

180

245700

1365

... More
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.

-

-

-

... More
Group A

20

11480

574

... More
Group B

20

12740

637

... More
Group C

267

238698

894

... More
Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.

5

4470

894

... More
Supplying and drawing following size of FRLS PVC insulated copper conductor single core cable in the existing surface/ recessed steel/ PVC conduit as required

-

-

-

... More
1 x 1.5 sq. mm

30

1350

45

... More
2 x 1.5 sq. mm

20

1400

70

... More
3 x 1.5 sq. mm

380

36100

95

... More
4 x 1.5 sq. mm

10

1200

120

... More
5 x 1.5 sq. mm

5

775

155

... More
6 x 1.5 sq. mm

110

19910

181

... More
9 x 1.5 sq. mm

80

22800

285

... More
1 x 4 sq. mm

144

12240

85

... More
2 x 4 sq. mm

30

4410

147

... More
3 x 4 sq. mm

210

43260

206

... More
4 x 4 sq. mm

40

11000

275

... More
6 x 4 sq. mm

32

12672

396

... More
3 x 6 sq. mm

10

3040

304

... More
6 x 6 sq. mm

10

5980

598

... More
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required

-

-

-

... More
1 Pair

20

620

31

... More
2 Pair

30

1140

38

... More
4 Pair

10

540

54

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

210

9870

47

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20 mm

1500

192000

128

... More
25 mm

800

116000

145

155

28520

184

50

11400

228

30

8520

284

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
5/6 A switch

267

27501

103

... More
2 way 5/6 A switch

10

1480

148

... More
15/16 A switch

72

11232

156

... More
3 pin 5/6 A socket outlet

20

2440

122

... More
6 pin 15/16 A socket outlet

72

14184

197

... More
Telephone socket outlet

48

7104

148

... More
TV antenna socket outlet

36

5328

148

... More
Bell push

10

1400

140

... More
25 amp switch

2

578

289

... More
16A, 240 V, , "C" curve, SP modular MCB

60

17580

293

... More
Computer Jack ( RJ 45) Cat6 (1 module)

52

15184

292

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

93

34317

369

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

30

1200

40

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.

-

-

-

... More
1 or 2 Module (75mmX75mm)

16

4768

298

... More
3 Module (100mmX75mm)

5

1635

327

... More
4 Module (125mmX75mm

3

1029

343

... More
6 Module (200mmX75mm)

25

10050

402

... More
8 Module (125mmX125mm)

5

2270

454

... More
12 Module (200mmX150mm)

28

15316

547

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.

-

-

-

... More
1 or 2 Module

15

1995

133

... More
3 Module

10

1510

151

... More
4 Module

5

790

158

... More
6 Module

10

1820

182

... More
8 Module

5

1055

211

... More
12 Module

10

2720

272

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.

53

25281

477

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

145

84970

586

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.

89

7743

87

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required.

5

655

131

... More
Installation, testing, commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/ CFL / LED lamps per fitting/ /Downlighters/ LED Panel Light /LED batten on wall or ceiling, complete with all accessories including connection and earthing etc. as required.

5

595

119

... More
Supplying and fixing Ding Dong Door Bell, suitable for single phase, 230 V, complete as required.

5

495

99

... More
Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required.

30

1200

40

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq, mm FRLS PVC insulated, copper conductor, single core cable etc. as required.

5

1065

213

... More
Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

5

230

46

... More
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

5

260

52

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.

-

-

-

... More
Upto 450 mm sweep

2

900

450

... More
510 mm sweep

2

1286

643

... More
Extra for fixing the louvers/ shutters complete with frame for an exhaust fan of all sizes.

2

414

207

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.

-

-

-

... More
1 run of cable

1200

68400

57

... More
2 run of cable

320

30720

96

... More
3 run of cable

200

26800

134

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group C

5

4290

858

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required.

177

120360

680

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 6 pin 15/16 A modular socket outlet and 2 nos. 15/16 A modular switch, connections etc. as required.

114

111150

975

... More
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 16 A modular socket outlet and 16 A modular SP MCB, "C" curve including connections, painting etc. as required.

73

56210

770

... More
Supplying and fixing PVC batten/ angle holder including connections etc. as required.

5

550

110

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
6 way , Double door

1

2206

2206

... More
8 way , Double door

1

2573

2573

... More
12 way , Double door

1

2315

2315

... More
16 way, Double door

12

37692

3141

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
4 way (4 + 12), Double door

1

4091

4091

... More
6 way (4 + 18), Double door

1

4974

4974

... More
8 way (4 + 24), Double door

5

29835

5967

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

330

84480

256

... More
Single pole and neutral

10

5990

599

... More
Double pole

15

9840

656

... More
Triple pole

2

2014

1007

... More
Triple pole and neutral

7

8596

1228

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

15

195

13

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

2

5284

2642

15

40830

2722

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

7

20104

2872

... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

2

2338

1169

... More
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.

2

3184

1592

... More
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.

-

-

-

... More
For 6 way, Double door SPN MCBDB

1

752

752

... More
For 8 way, Double door SPN MCBDB

1

832

832

... More
For 10 way/ 12 way, Double door SPN MCBDB

1

810

810

... More
For 14 way/16 way, Double door SPN MCBDB

12

10824

902

... More
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.

-

-

-

... More
For 4 way, Double door TPN MCBDB

1

1080

1080

... More
For 6 way, Double door TPN MCBDB

1

1124

1124

... More
For 8 way, Double door TPN MCBDB

5

6700

1340

... More
Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.

1

1170

1170

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required

-

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

160

154080

963

... More
450 mm width X 50 mm depth X 2.0 mm thickness

30

39750

1325

... More
600 mm width X 50 mm depth X 2.0 mm thickness

10

17900

1790

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

52

96304

1852

... More
450 mm width X 50 mm depth X 2.0 mm thickness

10

26830

2683

... More
600 mm width X 50 mm depth X 2.0 mm thickness

5

18870

3774

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

10

21560

2156

... More
450 mm width X 50 mm depth X 2.0 mm thickness

5

15705

3141

... More
600 mm width X 50 mm depth X 2.0 mm thickness

2

8892

4446

... More
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

6

41130

6855

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required.

72

20664

287

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

135

5670

42

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

8

59776

7472

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

42

29652

706

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

20

4880

244

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

8

4144

518

... More
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting /nut bolting/ sweating and soldering etc as required.

6

678

113

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

290

36540

126

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)

45

8865

197

... More
Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

10

800

80

... More
Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)

10

1620

162

... More
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

8

968

121

... More
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.

30

5850

195

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, down rod upto 30 cm long , 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 8, Air delivery minimum 215 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, without remote and compatible with existing step electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (BLDC Ceiling fan with minimum 2 year Warranty)

95

320340

3372

... More
Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe and making good the same etc. complete as per direction of Engineer-in-charge.

10

7450

745

... More
Supplying and fixing two module Buzzer on the existing modular plate switch box including connections but excluding modular plate etc. as required.

2

654

327

... More
Supplying and fixing two module bell/ chime on the existing modular plate switch box including connections but excluding modular plate etc. as required.

2

1018

509

... More
Supply, installation, testing and commissioning of wall-mounted light fixture complete with B22 base, metal base in Nickel / Brass finishing with diffuser and 9 watts LED blub etc., as required directly on the wall, including connections etc. as required.

2

2504

1252

... More
Supply, Installation, Testing and Commissioning of 900 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, down rod upto 30 cm long , 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6, Air delivery minimum 170 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, without remote and compatible with existing step electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (BLDC Ceiling fan with minimum 2 year Warranty)

2

6450

3225

... More
Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 7.00, Air delivery minimum 250 Cum/Min, 250 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

2

7170

3585

... More
Supply and installation of 400 mm sweep, 220 V, wall mounted fan along with speed regulator unit for speed control, on the existing wall, including connection, testing, commissioning etc. as required.

8

24976

3122

... More
Supplying and fixing 3 mm thick phenolic laminated sheet cover on existing switch Box / metal box with Al. Alloy/ cadmium/ zinc plated screws and washers, including cutting the laminated sheet to required shape and size etc., complete as required.

1

4170

4170

... More
Supplying and installation of PVC Exhaust fan with louver shutter 150 mm sweep in the existing opening including making the hole to suit the size of the above fan and making good the damage, connection, testing , commissioning etc as required.

2

4190

2095

... More
Supplying and installation of PVC Exhaust fan with louver shutter 200 mm sweep in the existing opening including making the hole to suit the size of the above fan and making good the damage, connection, testing , commissioning etc as required.

2

4564

2282

... More
Supplying and installation of PVC Exhaust fan with louver shutter 250 mm sweep in the existing opening including making the hole to suit the size of the above fan and making good the damage, connection, testing , commissioning etc as required. (Havells / C&G / Orient / Usha / Almonard/ Atomberg)

5

12165

2433

... More
Supplying and installation of 300 mm sweep, 1400 RPM heavy-duty, single phase, metallic exhaust fan Conforming to IS:2312 -1967 in the existing opening,including making the hole to suit the size of the above fan and making good the damage, connection, testing, commissioning etc. as required. (Havells Turbo force Heavy Duty Exhaust Fan or with similar specifications C&G / Orient / Usha / Almonard)

10

50700

5070

... More
Supplying and installation of 450 mm sweep, 1400 RPM heavy-duty, single phase, metallic exhaust fan Conforming to IS:2312 -1967 in the existing opening,including making the hole to suit the size of the above fan and making good the damage, connection, testing, commissioning etc. as required. (Havells Turbo force Heavy Duty Exhaust Fan or with similar specifications C&G / Orient / Usha / Almonard)

1

8264

8264

... More
Supplying and installation of 225/ 230 mm sweep, single phase, metallic exhaust fan in the existing opening,including making the hole to suit the size of the above fan and making good the damage, connection, testing, commissioning etc. as required. (Havells Ventil Air or with similar specifications C&G / Orient / Usha / Almonard)

1

2285

2285

... More
Making holes of the required size and shape in a brick masonry wall for installation of the following size exhaust fan, including making good the wall by plastering and finishing with the matching surface, etc., complete as per the direction of the engineer-in-charge.

-

-

-

... More
150 mm sweep.

2

182

91

... More
200 mm sweep.

2

272

136

... More
250 mm sweep.

5

960

192

... More
450 mm sweep.

2

1004

502

... More
225/ 230 mm sweep

1

138

138

... More
Cutting a hole of the required size and shape on the window or ventilator glass pane for the installation of an exhaust fan of size up to 150 mm sweep, etc., complete as per the direction of the engineer-in-charge.

1

118

118

... More
Supply and fixing of 8 mm thick BWP/marine grade plywood wood board having a circular /rectangular hole to suit the sie of exhaust fan upto 380 mm on wall /window for etc as required including the cost of making hole, nuts and bolts, etc. as required.

2

1252

626

... More
Supplying and fixing suitable size GI box in recess, including providing and fixing of 2/3 Module LED Foot light / skirting light, including connection etc. as required.

2

1762

881

... More
Supply, installation, testing, and commissioning of integrated LED Batten luminaire, 1100 mm (nominal size) with a minimum system lumen output of 4800 lumen and with a minimum system luminous efficacy of 120 lm/W, made of aluminium housing having a colour temperature 5500K - 6500 K, Average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required.

5

7110

1422

... More
Supply, installation, testing, and commissioning of integrated LED Batten luminaire, 1100 mm (nominal size) with a minimum system lumen output of 2400 lumen and with a minimum system luminous efficacy of 120 lm/W, made of aluminium housing having a colour temperature 5500K - 6500 K, Average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required.

33

28314

858

... More
Supply, installation, testing, and commissioning of integrated LED Batten luminaire, 600 mm (nominal size) with a minimum system lumen output of 1000 lumen and with a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature 5500K - 6500 K, Average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required.

2

1246

623

... More
Supply, installation, testing, and commissioning of LED bulkhead fittings with IP 66 ingress protection, with a minimum system lumen output of 1000 lumens and a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature of 5500K–6500 K, average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser, electronic driver, etc. as required directly on the wall, including connections, etc. as required.

6

10020

1670

... More
Supply, installation, testing and commissioning of surface mounted LED downlighter luminaire in metallic housing, with a minimum system lumen output of 1500 lumen and with a minimum system luminous efficacy of 100 lm/W, Average LED life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser and electronic driver, directly on ceiling, including connections and earthing etc. as required.

7

17031

2433

... More
Supply, installation, testing, and commissioning of 2 ft. x 2 ft. (nominal size) LED Surface Mounted LED Panel Light, in metallic housing, with a minimum system lumen output of 3960 lumens and a minimum system luminous efficacy of 110 lm/W, colour temperature of 5500K–6500K, average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling, including connections, earthing, etc. as required.

89

386171

4339

... More
Supply, installation, testing, and commissioning of 2 ft. x 2 ft. (nominal size) LED recessed Mounted LED Panel Light, in metallic housing, with a minimum system lumen output of 3960 lumens and a minimum system luminous efficacy of 110 lm/W, colour tem perature of 5500K–6500K, average life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, suitable for recessed mounting, Armstrong/grid/POP/GB ceiling complete with all accessories, diffuser and electronic driver, directly on the ceiling, including connections and earthing etc. as required.

107

378138

3534

... More
Supply, installation, testing, and commissioning of recess mounted LED downlighter luminaire complete with aluminium powder coated pressure die cast housing and PC diffuser and electronic driver, with a minimum system lumen output of 1800 lumens and a minimum system luminous efficacy of 100 lm/W, average LED life L70B50: 50000 hours, THD ≤ 10%, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, and suitable for ceiling cutout of 187 mm, complete with all accessories, diffuser and electronic driver, directly on ceiling, including connections and earthing, etc. as required.

10

20950

2095

... More
Providing and fixing a metallic louvred shutter suitable for following sizes exhaust fan, the louvres should be able to open when the fan is on and close when the fan is turned off, on the existing opening on the wall, etc., as required.

-

-

-

... More
300 mm

1

809

809

... More
380 mm

1

1034

1034

... More
450 mm

1

1331

1331

... More
Providing and fixing 3 mm thick PVC/ phenolic laminated round sheet cover with a minimum of 170 mm dia on the existing fan box with two screws, etc., as required.

89

2670

30

... More
Providing and fixing 3 mm thick PVC / phenolic laminated round sheet cover on the existing junction box with two screws, etc., as required.

110

880

8

... More
Supply, installation, testing, and commissioning of outdoor type 3-watt IP 65 LED foot light/ step light in Die cast aluminium housing and Polycarbonate diffuser, complete with connection, etc., as required. (Jaquar LFTL01S003XW or similar in Philips / Wipro /LT/ Havells)

2

1572

786

... More
Supplying and fixing following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required

-

-

-

... More
40 A Double pole

5

6065

1213

... More
63 A Double pole

15

18195

1213

... More
Supplying and fixing following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
40 A Triple pole and neutral

1

2324

2324

... More
63 A Triple pole and neutral

7

16268

2324

... More
Fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
6 to 16 way, Double door

5

2540

508

... More
Fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

10

940

94

... More
Supplying, installation, testing and commissioning of 45 Watt LED street light luminaire made up of die-cast aluminium housing, with IP66 degree of protection, complete with the driver, LEDs with optical lens, toughened glass cover, etc. The luminaire should have suitable for operation on voltage range 140-270V, 1Φ, 50Hz AC supply system, and a mechanical impact resistance rating of lk=07. surge protection of ≥ 10KV, PF≥ 0.90 and minimum system luminous efficacy of 120 lm/W. The luminaire shall be designed for an average system life L70B50: 50000 hours and suitable for mounting on the pole bracket up to outer dia 40 mm, including installation on existing street light pole bracket connections and earthing etc., as required. LM 79 and LM 80 reports need to be submitted from a NABL/UL accredited lab to verify the above parameters.

10

47740

4774

... More
Supplying, installation, testing and commissioning of 2 Ton, Inverter type, 5 Star BEE rating, Hi-wall Split type Air conditioner complete suitable for operation on 230 V, 50 Hz single phase AC supply, with all standard accessories ( Indoor Unit, Outdoor Unit, Inter-connecting kit with copper pipe wrapped with insulation, Drain pipe and connecting cable, copper Condenser and Evaporator Coil, remote control, user manual with warranty certificate as per OEM specifications). i) Connecting copper pipes and cable length minimum 3 mtrs. ii)Warranty : minimum 1 Year on complete Unit, PCB warranty 5 Years and 10 Years on Compressor. iii) Cooling capacity (100%) as per BEE label : 7000 Watt minimum iv) Rated ISEER : minimum 5 v) The AC should be designed to work at a maximum operating ambient temperature of up to 52 degrees Celsius (outdoor temperature).

2

167024

83512

... More
Supplying, installation, testing and commissioning of 1.5 Ton, Inverter type, 5 Star BEE rating, Hi-wall Split type Air conditioner complete suitable for operation on 230 V, 50 Hz single phase AC supply, with all standard accessories ( Indoor Unit, Outdoor Unit, Inter-connecting kit with copper pipe wrapped with insulation, Drain pipe and connecting cable, copper Condenser and Evaporator Coil, remote control, user manual with warranty certificate as per OEM specifications). i) Connecting copper pipes and cable length 3 mtrs. ii)Warranty : minimum 1 Year on complete Unit, PCB warranty 5 Years and 10 Years on Compressor. iii) Cooling capacity (100%) as per BEE label : 5200 Watt minimum iv) Rated ISEER : minimum 5 v) The AC should be designed to work at a maximum operating ambient temperature of up to 52 degrees Celsius (outdoor temperature).

10

647630

64763

... More
Providing and fixing of extra refrigerant copper piping with insulation and cable for 1.5 ton/2 ton Split AC as per manufacturers specification , clamps, etc. complete as reqd. ( two copper pipes one suction and one discharge line with connecting cable and foam insulation tubing will be measured as one unit) .

10

8930

893

... More
Dismatling of existing of 1.5 ton /2.0 ton split air conditioner with indoor unit, out door unit and copper piping etc complete as reqd.

10

8060

806

... More
Supplying and fixing of floor mounted / wall mounted Out Door Unit Mounting bracket suitable for 1.5/ 2 ton split Air conditioner etc complete as required.

10

9700

970

... More
Supplying and laying of following sizes of PVC insulated, FRLS PVC sheathed round copper conductor multi core cable including connections, testing etc. as required.

-

-

-

... More
3 x 2.5 sq. mm

20

2980

149

... More
4 x 2.5 sq. mm

40

7800

195

... More
Supplying and installing the following size PVC trunking cable management system, complete with front cover, internal/external/flat angles, joints, junctions, end caps, and finishing accessories, etc. as required. (Make-Legrand/ Honeywell / OBO Beterman)

-

-

-

... More
100 mm x 50 mm

25

38600

1544

... More
32 mm X 12.5 mm

20

6200

310

... More
Supplying and fixing of following sizes module frame on existing trunking including arranging the cover making good the same as original complete etc. as required. (Make-Legrand/ Honeywell / OBO Beterman)

-

-

-

... More
1-3 Module Frame

2

400

200

... More
4-5 Module Frame

2

478

239

... More
8 Module Frame

2

776

388

... More
Providing and fixing 1/2 inches dia nylon braided flexible drain pipe for split/cassettee air conditioners etc. as required

50

3300

66

... More
Providing and fixing CPVC pipe 20 mm dia with all accessories e.g. elbows, unions, sockets, reducers, reducing tees, nipples etc., including fixing the pipe with clamps at 1.00 m spacing on wall / floor etc. as required. (Ashirwad /Astral /Finolex/ Supreme/ Prayag )

30

5520

184

... More
Supplying, installation testing and commissioning of BEE 5 star rating, 15 litres capacity water storage heater, with protection against over heating, Multifunction Safety Valve and external adjustable thermostat, with 16 A, 240 V, plug top and 02 nos flexible connection pipe suitable for working with 230V AC, 50 Hz, 1 Phase supply etc as required. (Make: Havells / Crompton/ AO Smith /Racold /Jaguar with 7 year warranty on inner tank, 3 year warranty on heating element, 2 year comprehensive Warranty)

1

9762

9762

... More
Supplying and fixing PRCD (Portable Residual Current Device) Plug top, 16 A 30 mA rating including connection etc. as required.

1

777

777

... More
Supplying and installing following size of perforated hot-dipped galvanized iron cable tray with 1.6 mm G.I. sheet cover in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders, or fixed on the wall /floor  with M.S. angle iron brackets duly painted, including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

40

23680

592

... More
300 mm width X 50 mm depth X 1.6 mm thickness

10

16870

1687

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Bends" with 1.6 mm G.I. sheet cover, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders, or fixed on the wall /floor  with M.S. angle iron brackets duly painted, including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

10

14410

1441

... More
300 mm width X 50 mm depth X 1.6 mm thickness

2

3936

1968

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" with 1.6 mm G.I. sheet cover, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders, or fixed on the wall /floor  with M.S. angle iron brackets duly painted, including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

2

2960

1480

... More
300 mm width X 50 mm depth X 1.6 mm thickness

2

4570

2285

... More
Supplying and fixing Plug top following rating including connection etc. as required.

-

-

-

... More
16 A, three pin, Plug top ISI marked

15

1845

123

... More
6 A, three pin, Plug top ISI marked

10

1000

100

... More
25 A, three pin, Plug top ISI marked

2

380

190

... More
Supplying and fixing bakelite sheets of the following size with screws in the existing looping box or panel, including cutting the sheet to the required shape and size, etc., as required.

-

-

-

... More
6 mm thick

0.25

1079

4317

... More
Supplying and fixing 25 A modular SP MCB, "C" curve on the existing modular plate switch box including connections but excluding modular plate etc. as required.

72

21168

294

... More
Supplying and laying of G.I. pipe of 50 mm dia.(nominal), medium class, ISI marked in wall / floor including cutting chase, and making good the wall/ floor and finishing with matching surface after housing G.I. pipe in chase. ( for protection of UG cable)

20

16280

814

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.

-

-

-

... More
63 mm dia (OD-63 mm & ID-51 mm nominal)

15

1905

127

... More
90 mm dia (OD-90 mm & ID-76 mm nominal)

10

1710

171

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
63 mm dia (OD-63 mm & ID-51 mm nominal)

160

39520

247

... More
90 mm dia (OD-90 mm & ID-76 mm nominal)

100

29200

292

... More
Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
2 X 25 sq. mm

50

15350

307

... More
3.5 x 35 sq. mm

110

58410

531

... More
3.5 x 70 sq. mm

100

95700

957

... More
Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size in the existing masonry open duct / along pole / loose for connections etc as required.

-

-

-

... More
2 X 25 sq. mm

5

1480

296

... More
3.5 x 35 sq. mm

20

10420

521

... More
3.5 x 70 sq. mm

20

18860

943

... More
Supplying, Laying and fixing of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size on wall surface as required.

-

-

-

... More
3.5 x 35sq. mm (clamped with 1mm thick saddle)

20

10980

549

... More
3.5 x 70 sq. mm (clamped with 25x3mm MS flat clamp)

30

31080

1036

... More
Supplying, laying and fixing of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 KV grade of following size on cable tray as required.

-

-

-

... More
3.5 x 35 sq. mm (clamped with 1mm thick saddle)

30

16290

543

... More
3.5 x 70 sq. mm (clamped with 25x3mm MS flat clamp)

60

62160

1036

... More
PANEL NO.01 Essential Panel (CCC Block Switch Room)

-

-

-

... More
Fabrication, supply, installation, testing, and commissioning of Electrical control panel of cubical construction, floor-mounted type, fabricated out of a 2 mm thick CRCA sheet with enclosure protection class IP 42, suitable for operation on a 415-volt, 3-phase, 50 Hz, 4-wire A.C. supply system, dust- and vermin-proof, powder-coated in an approved siemens gray shade after 7 tank pre-treatment processes. The panel shall be compartmentalized type with hinged lockable doors, detachable cable gland plates made of 3 mm thick CRCA sheet, cable alleys of suitable size on both sides for cabling routing, openable type rear cover and complete with 4 strips of Aluminium bus bars of 400 Amps capacity with heat-shrinkable coloured sleeves and FRP/DMC/SMC bus bar supports at required intervals, control terminals, and suitable sized terminal blocks for incoming and outgoing cables, including providing and fixing interconnection from busbars to switch gears and up to terminal blocks with suitable sized insulated aluminium conductor /solid aluminium strip and control wiring with suitable sized insulated copper conductor cable, including suitable size M.V. danger board fixed on panel. The entire panel shall have one common copper bar of size 25 mm x 5 mm at the rear with two earth studs/terminals. The panel shall be supplied with a bottom base MS channel, not less than 100 mm x 50 mm x 5 mm thick. Suitable size of M.V. Danger Boards shall be fixed on panel. The panel base should have four 300 mm long legs (made of angle irons 50 x 50 x 6 mm or other suitable means) to raise the panel from the floor, and a removable 2 mm thick powder-coated CRCA sheet cover must be provided on four sides of the pedestal. The base frame of the panel should be grouted into the floor with four 12mm dia x 200mm long bolts and nuts. The panel shall have provision to accommodate the following switch gears as mentioned below in Item No 146 and with the required front area (approximate front area 1.800 mm X 1500 mm) and depth minimum 450 mm. (Drawings will be approved before fabrication of the panel).

2.7

118854

44020

... More
Providing and fixing the following switch gears, metres, and accessories on the existing cubicle panel board, including drilling holes in the panel, making connections, testing and commissioning, etc. as required.

-

-

-

... More
250 Amps , four pole, MCCB, 36 KA breaking capacity , Ics = 100% Icu with Microprocessor release with overload, short circuit and earth fault protection and terminal spreaders.

2

96754

48377

... More
Extended Rotary Handle (RHOM) for 250 A MCCB

2

3766

1883

... More
250 Amps , 4 pole, 415 V, category AC-23A. On Load Change Over Switch, in open execution.

1

16153

16153

... More
3 ph Multifunction meter for the measurement of parameters voltage, current, power factor, frequency, KW and KWH Flush mounting.

1

3467

3467

... More
MCB SP 2A, C-Curve 10kA

3

1323

441

... More
CT 250/5 A amps, 10VA with class 1.0 accuracy

3

2157

719

... More
LED Indicator Lamp, Red. 240 V AC.

1

152

152

... More
LED Indicator Lamp,Yellow. 240 V AC.

1

152

152

... More
LED Indicator, Lamp, Blue, 240V AC.

1

247

247

... More
160 Amps , TP, MCCB, 36 KA breaking capacity with Spreader Terminals, Ics = 100% Icu with Adjustable overload and Adjustable short-circuit protection.

2

30392

15196

... More
Direct Rotary Handle (RHOM) for 160 A MCCB

2

2534

1267

... More
100 Amps , TP, MCCB, 36 KA breaking capacity with Spreader Terminals, Ics = 100% Icu with Adjustable overload and Adjustable short-circuit protection.

3

31704

10568

... More
Direct Rotary Handle (RHOM) for 100 A MCCB

3

3801

1267

... More
63 Amps , TP, MCCB, 36 KA breaking capacity with Spreader Terminals, Ics = 100% Icu with Adjustable overload and Adjustable short-circuit protection.

1

10568

10568

... More
Direct Rotary Handle (RHOM) for 125 A MCCB

1

1267

1267

... More
PANEL NO.02 (CCC Block Switch Room )

-

-

-

... More
Fabrication, supply, installation, testing, and commissioning of Electrical control panel of cubical construction, floor-mounted type, fabricated out of a 2 mm thick CRCA sheet with enclosure protection class IP 42, suitable for operation on a 415-volt, 3-phase, 50 Hz, 4-wire A.C. supply system, dust- and vermin-proof, powder-coated in an approved siemens gray shade after 7 tank pre-treatment processes. The panel shall be compartmentalized type with hinged lockable doors, detachable cable gland plates made of 3 mm thick CRCA sheet, cable alleys of suitable size on both sides for cabling routing, openable type rear cover and complete with 4 strips of Aluminium bus bars of 400 Amps capacity with heat-shrinkable coloured sleeves and FRP/DMC/SMC bus bar supports at required intervals, control terminals, and suitable sized terminal blocks for incoming and outgoing cables, including providing and fixing interconnection from busbars to switch gears and up to terminal blocks with suitable sized insulated aluminium conductor /solid aluminium strip and control wiring with suitable sized insulated copper conductor cable, including suitable size M.V. danger board fixed on panel. The entire panel shall have one common copper bar of size 25 mm x 5 mm at the rear with two earth studs/terminals. The panel shall be supplied with a bottom base MS channel, not less than 100 mm x 50 mm x 5 mm thick. Suitable size of M.V. Danger Boards shall be fixed on panel. The panel base should have four 300 mm long legs (made of angle irons 50 x 50 x 6 mm or other suitable means) to raise the panel from the floor, and a removable 2 mm thick powder-coated CRCA sheet cover must be provided on four sides of the pedestal. The base frame of the panel should be grouted into the floor with four 12mm dia x 200mm long bolts and nuts. The panel shall have provision to accommodate the following switch gears as mentioned below in Item No 149 and with the required front area (approximate front area 1.800 mm X 1500 mm) and depth minimum 450 mm. (Drawings will be approved before fabrication of the panel).

2.7

118854

44020

... More
Providing and fixing the following switch gears, metres, and accessories on the existing cubicle panel board, including drilling holes in the panel, making connections, testing and commissioning, etc. as required.

-

-

-

... More
250 Amps , four pole, MCCB, 36 KA breaking capacity , Ics = 100% Icu with Microprocessor release with overload, short circuit and earth fault protection and terminal spreaders.

2

96754

48377

... More
Extended Rotary Handle (RHOM) for 250 A MCCB

2

3766

1883

... More
250 Amps , 4 pole, 415 V, category AC-23A. On Load Change Over Switch, in open execution.

1

16153

16153

... More
3Ph LED Ammeter Cl 1 with Inbuilt selector switch for 3 phases.

1

1156

1156

... More
3Ph LED Voltmeter Cl 1 (0-500V) with Inbuilt selector switch for 3 phases.

1

1156

1156

... More
MCB SP 2A, C-Curve 10kA

3

1323

441

... More
CT 250/5 A amps, 10VA with class 1.0 accuracy

3

2157

719

... More
LED Indicator Lamp, Red. 240 V AC.

1

152

152

... More
LED Indicator Lamp,Yellow. 240 V AC.

1

152

152

... More
LED Indicator, Lamp, Blue, 240V AC.

1

247

247

... More
160 Amps , TP, MCCB, 36 KA breaking capacity with Spreader Terminals, Ics = 100% Icu with Adjustable overload and Adjustable short-circuit protection.

1

15196

15196

... More
Direct Rotary Handle (RHOM) for 160 A MCCB

1

1267

1267

... More
100 Amps , TP, MCCB, 36 KA breaking capacity with Spreader Terminals, Ics = 100% Icu with Adjustable overload and Adjustable short-circuit protection .

2

21136

10568

... More
Direct Rotary Handle (RHOM) for 100 A MCCB

2

2534

1267

... More
80 Amps , TP, MCCB, 36 KA breaking capacity with Spreader Terminals, Ics = 100% Icu with Adjustable overload and Adjustable short-circuit protection .

2

21136

10568

... More
Direct Rotary Handle (RHOM) for 80 A MCCB

2

2534

1267

... More
63 Amps , TP, MCCB, 36 KA breaking capacity with Spreader Terminals, Ics = 100% Icu with Adjustable overload and Adjustable short-circuit protection.

1

10568

10568

... More
Direct Rotary Handle (RHOM) for 125 A MCCB

1

1267

1267

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

50

6685

133.7

... More
Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete.

4

2255

563.9

... More
The road crossings of power cable through trenchless boring. Trenchless boring using Manual/ Machine Moling technique at 0.75 metre below the ground level for following size pipes, including survey of under ground utilities, excavation of pits, moling with the hole size not exceeding 20% of the pipe dia, backfilling, compaction and restoration of the pits to original condition etc. as required. The rates for moling, as indicated are inclusive of excavation of pits, backfilling, compaction and restoration of the pits to original condition. Any damages occurred to other utilities during the Moling operation shall be immediately notified and rectified by the contractor without any cost implication to the Department. The length of the Hole (excluding the sizes of the pits on both ends) shall be considered for the measurement of Moling length. However, intermediate pits will consider in the moling length. i) Upto 150 mm dia DWC HDPE / G.I. /PVC

10

6510

651

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching(75 cm deep) and refilling etc.

-

-

-

... More
50 mm dia nominal bore

10

7621

762.15

... More
80 mm dia nominal bore

10

10417

1041.7

... More
Dismantling of the existing switch accessories like switches, sockets, and MCBs, etc., as required.

350

1400

4

... More
Dismantling of the existing ceiling rose, holder, and wall bracket and depositing the same with the listing of materials in the store.

267

2403

9

... More
Dismantling of existing fluorescent fitting from ceiling/ wall including making good the damage to match the adjacent surface, etc., as required.

189

4347

23

... More
Dismantling of the existing ceiling fan/ exhaust fan of any size installed in the building and depositing it in the MMC store.

89

5251

59

... More
Dismantling of the existing recessed vertical type or horizontal type TPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required.

5

1075

215

... More
Dismantling of the existing recessed SPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required.

12

1956

163

... More
Dismantling of the existing recessed switch board of light points/power points, power/light plug points/socket outlet metal boxes of any size, along with phenolic laminated sheet, switches, sockets, etc., making good the damage to match the adjacent surface, etc., as required.

220

15180

69

... More
Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it. Above 25 mm conduits.

520

3640

7

... More
Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it. Up to 25 mm conduit.

110

330

3

... More
Dismantling / de-commissioning of the existing roof top solar panels and accessories from the roof and re-installation of the same after completion of the roof treatment work in CCC block, including making connections, testing, commissioning, etc. as required, and providing consumables, nuts, bolts washers, etc. that are required during re-installation of the solar power plant.

40

354000

8850

... More
Manual Fire Alarm System

-

-

-

... More
Supplying, installation, testing & commissioning of heat detector operating at 54°C/57°C with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.

20

21420

1071

... More
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.

100

115300

1153

... More
Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.

10

4080

408

... More
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.

10

4910

491

... More
Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required.

10

9050

905

... More
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.

-

-

-

... More
4 Zone

2

17732

8866

... More
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.

30

5880

196

... More
Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required- 2 Nos. (one to act as standby)

-

-

-

... More
Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos. talk back unit -1 set.

-

-

-

... More
Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set.

-

-

-

... More
Amplifier change over switch for inter changing amplifier- 1 No.

-

-

-

... More
Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set.

-

-

-

... More
Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set.

1

48718

48718

... More
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

1000

173000

173

... More
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.

-

-

-

... More
Speaker cable Single pair, 2-core, 1.5 sqmm

50

2700

54

... More
Speaker cable Two pair, 2-core, 1.5 sqmm

100

8900

89

... More
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.

50

2650

53

... More
Providing and Fixing CO2 type, 4.5 kgs, capacity Fire Extinguishers with ISI mark in seam less drawn steel cylinder, fitted with wheel valve, with discharge bend and horn, complete with initial charge, conforming to IS 15683 along with wall bracket, accessories etc., complete as required

6

49524

8254

... More
Providing and Fixing ABC type 6 kgs capacity, stored pressure type Fire Extinguishers with ISI mark, fitted with discharge control valve and pressure gauge, filled with mono ammonium phosphate powder, complete with initial charge conforming to IS 15683 along with wall bracket, along with accessories etc., complete as required.

6

22770

3795

... More
Supplying and fixing of Emergency Exit Light minimum 3 watt, Nominal size 300 mm x 150 mm (double side) alongwith 2 hours battery backup i/c all necessary connections/ interconnections with suspension kit/ other reqd accessories if any as required .

8

49864

6233

... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

200

44600

223

... More
CCTV and surveillance system and access control work

-

-

-

... More
Supply, installation, Testing & Commissioning of Fixed Dome Indoor 1080p True Day/Night Switching IP camera. Complete in all respect upto entire satisfaction Engineer in charge of works. Specification:- Image device/ Sensor - 1/2.8 " Progressive Scan CCD/ Progressive Scan CMOS or Better, Resolution - 2 Megapixel (1920x1080) or better, Frame Rate upto 25/30 Fps or better, Lens type - 2.8mm / 4mm lens, IR Light & Distance - Ir Range upto 30 mrs or better, Signal to Noise Ratio -50db, Minimum Illumination - 0.3Lx Color, IR LED ON 0.0 Lux or better, Day Night - Auto Day/ Night with switchable IR cut filter, Video Compression - H.265, H.264, M-JPEG, Camera Should have multiple Streaming- Min. Triple, Edge Based Analytics, Storage- SD card slot should be expandable upto 256 GB, System Compatibility- ONVIF profile S&G, Privacy Masking- Minimum 4 Privacy zones or Higher, Protocols - IPv4/ IPv6, HTTP, HTTPS, TCP/IP, UDP, UPnP, ICMP, RTSP, RTP, SMTP, NTP, DHCP, DNS, DDNS . Additional Features :- Noise Reduction - Digital Noise reduction on/off, WDR- 120dB WDR, Audio Input/ Output - 1 Audio Input Environment : - Indoor/ Outdoor, Operating Temperature -OC to 50C, Ingress protection & Vandal resident Standards - IP66 or Better IK 10 or better, Certificates :- UL/BIS, FCC, EN (Make:-Hyundai /Bosch/Pelco/Axis/ Avigilon /Honeywell)

46

1012000

22000

... More
Supply, installation, Testing & Commissioning of Full HD 2 MP IR Bullet IR Camera. in all respect upto entire satisfaction Engineer in charge of works. Specification:- Image device/ Sensor - 1/2.8 " Progressive Scan CCD/ Progressive Scan CMOS or Better, Resolution - 2 Megapixel (1920×1080) or better, Frame Rate upto 25/30 Fps or better, Lens type - 2.8mm / 4mm lens, IR Light & Distance - Ir Range upto 30 mtrs or better, Signal to Noise Ratio -50db, Minimum Illumination - 0.3Lx Color, IR LED ON 0.0 Lux or better, Day Night - Auto Day/ Night with switchable IR cut filter, Video Compression - H.265, H.264, M-JPEG, Camera Should have multiple Streaming- Min. Triple, Edge Based Analytics, Storage- SD card slot should be expandable upto 128 GB, System Compatibility-ONVIF profile S&G, Privacy Masking- Minimum 4 Privacy zones or Higher, Protocols - IPv4/ IPv6, HTTP, HTTPS, TCP/IP, UDP, UPP, ICMP, RTSP, RTP,SMTP, NTP, DHCP, DNS, DDNS. Additional Eeatures • Noise Reduction - Jigital Noise reduction on/off, WDR- 120dB WET Of 3 Input/ Output - 1 Alarm Input, 1 Alarm Output, Audio Input/ Outputo Input, 1 Audio Output. Environment :- Indoor/ Outdoor, Operating Temperature -OC to 50C, Ingress protection & Vandal resident Standards - IP66 or Better IK10 or better, Certificates :- UL/BIS, FCC, EN Make:- Hyundai /Bosch/Pelco/Axis/ Avigilon /Honeywell)

11

251900

22900

... More
Supply, installation, Testing & Commissioning of Network Video Recorder 32 Channel for all the above ONVIF Compliant Cameras, complete with all necessary required electrical works de peripheral items as required as per specification & at site of work in line with the engineer in charge instructions. The System proposed should have minimum usable 30 days recording suitable hard disk as per requirement. Certifications UL hard disk complete in all respect upto entire satisfaction Engineer in charge of works. 16 Channels from day 1, IP Camera Input -32 cameras Simultancous live, record, playback, extraction and remote access front, mouse or remotely operated, Internal Storage - 32 Channel: with 18 TB Storage, 4 SATA Hard disk slots, Video compression format-H.265, H.264 and MJPEG, OS Supported- Window Server 2008/ Linux/Windows 10, Ethernet Card- Single LAN (10/100/1000) Network Card with asset feature tracking and security management, remote wake up. Complete in all respects with all the required software, etc., as required, as per the instructions of the engineer in charge. Certification:- ISO 9001/9002, FCC, UL/BIS Make:-Hyundai/Bosch/Pelco/Axis/ Avigilon /Honeywell)

3

660000

220000

... More
Supply, installation, Testing & Commissioning of Wall Mount 9U x 600W x 600 D, Front Glass Door (tinted, Toughened) with Lock & Key, 2 pairs of 19" Mounting Rails with U-Marking. Welded Side Walls With Metal Engraved D-Link Logo, 1U Cable Manager (1), Hardware Packet (1 Pkt),6 Socket 5 Amp. Power Distribution Unit (1 No)Roof Mounted Fan Unit / 90 CFM /230V AC (1 No).Rack should be as per DIN41494 Standards.OEM must be ISO 9001,14001 certified. Make:- HCL. /Dlink/Comrack/Ritall/Western

3

29700

9900

... More
Supply, installation, Testing & Commissioning of 8-ports 10/100/1000Base-T PoE Switch plus 2 SFP ports with Cable Diagnostics +8,000 mac entries+8 ports 802.3at compliant with total of 130W+ CoS based on 802.1p Priority Queues,DSCP,Bandwidth Control;HOL Blocking Prevention;Spanning tree +-4 IP interface +4 queues per port+Static Routing. Broadcast/Multicast/Unicast Storm Control+IPv4/\6 Dual Stack+802.3x Flow Control+Port Security supports 64 MACs per port. Make:- Cisco/Alcatel/Juniper/Dlink

1

23000

23000

... More
Supply, installation, Testing & Commissioning of 24-ports 10/100/1000Base-T PoE Switch plus 2 SFP ports with Cable Diagnostics +24,000 mac entries + 24 ports 802.3at compliant with total of 220W+ CoS based on 802.1p Priority Queues,DSCP,Bandwidth Control;HOL Blocking Prevention;Spanning tree +-4 IP interface +4 queues per port+Static Routing. Broadcast/Multicast/Unicast Storm Control+IPv4/\6 Dual Stack+802.3x Flow Control+Port Security supports 64 MACs per port. Make:- Cisco/Alcatel/Juniper/Dlink

3

126000

42000

... More
Supply, installation, Testing & Commissioning of 42" LED Monitor, Full HD, HDMI Port, Component Video Inputs, 1 Digital Audio Out, VGA Port. Make: Sony/LG/Samsung

3

141000

47000

... More
Supply, installation, Testing & Commissioning of 2 KVA Online UPS with isolation transformer suitable for single phase AC Input and single Phase AC output, Floor Mounted type Rating of UPS 2 KVA, Indicative Backup time 120 Minutes Complete in all respect including bettery etc. as per DGS&D Specification. Make :- APC/ LIBERT EINOVA/Emerson/Aar Key

3

330000

110000

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

300

69900

233

... More
Supply, installation, testing, and commissioning of access control systems incorporating facial and fingerprint recognition, capable of accommodating 5000 or more users. This includes a comprehensive setup designed for installation on access control gates, complete with magnetic locks, controllers, and application software tailored to meet site-specific requirements. Complete in all respects with all the required software, etc., as required, as per the instructions of the engineer in charge. Certifications: CE, FCC, KC, ROHS, WEEE, REACH, BIS (Make : Bosch/Honeywell/HID/VIRDI

3

225000

75000

... More
Supply, installation, testing, and commissioning of a system featuring an Intel Core i7 processor, 16GB RAM, dual 512GB SSDs, and a 20-inch LED display, integrated with an access control application for running the Access Control Biometric Application. (Make : Dell/HP/Lenovo/Acer)

1

110000

110000

... More
ADD labour cess @1 % on DSR 2022 (Elect.) amount Rs. 45,64,531/-

1

45645

45645.31

... More
Add Difference in GST of(18 &12 %) by MF 0.0633 on DSR Elect i.e Rs. 45,64,531/- (DSR) + 45645.31 (L/Cess) = 46,10,176.31

1

291824

291824.16

... More
Less COST INDEX on DSR( E ) @ -2.73 % i.e Rs. 45,64,531/- (DSR) + 45645.31 (L/Cess) + Rs. 2,91,824.16 (GST difference) = Rs. 49,02,000.47

1

-133824

-133824.61

... More
Correction factor on existing items of DSR @0.973 as per CPWD office Memorandum 158/SE (TAS)/GST/2024/02-E DATED 8-8-2024 (U) i.e Rs. 45,64,531/- (DSR) + 45,645.31 (L/Cess) + Rs. 2,91,824.16 (GST difference) + 26,979.10 (DSR Civil) - 1,33,824.61 = Rs. 47,95,154.96

1

-129469

-129469.18



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.