National Security Guard Tender

... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

National Security Guard - NSG Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date22 Apr 2025
Closing Date28 Apr 2025
Tender Amount₹ 61,34,565 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
3½ X 400 sq. mm

10

4257

42570

... More
CTs 100/5 A, to 600/5A amps 415 volt.

9

24

216

... More
150 mm dia nominal bore

36

2740

98640

... More
Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.

-

-

-

... More
3 ph Multifunction meter for the measurement of parameters voltage, current, power factor, frequency, KW and KWH Flush mounting type.

1

4391

4391

... More
3½ X 150 sq. mm

2

4538

9076

... More
Location, tracing and pin-pointing of faults in existing 1.1 KV and 11KV grade underground cables, including disconnection of the cable at both ends, finding the route of the cable, excavation at the fault point to make the fault point visible, making temporary joints ( in case of LT cable), testing the cable on load for three hours, including refilling the excavated trench and cleaning the site, etc. as required(Permamnent joints will be paid separately ).

5

10056

50280

... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. [Make-Raychem/3M/M-seal]

-

-

-

... More
LED Indicator Red, 240V AC/ 24 DC. (L & T, Siemens, BCH, Telemecanique, Vaishnav, Legrand/ Kaypee)

24

153

3672

... More
The road crossings of power cable through trenchless boring. Trenchless horizontal boring using Manual/ Machine Moling technique at 0.75 metre below the ground level for following size pipes, including survey of under ground utilities, excavation of pits, moling with the hole size not exceeding 20% of the pipe dia, backfilling, compaction and restoration of the pits to original condition etc. as required. The rates for moling, as indicated are inclusive of excavation of pits, backfilling, compaction and restoration of the pits to original condition. Any damages occurred to other utilities during the Moling operation shall be immediately notified and rectified by the contractor without any cost implication to the Department. The length of the Hole (excluding the sizes of the pits on both ends) shall be considered for the measurement of Moling length. However, intermediate pits will consider in the moling length. i) Upto 200 mm dia DWC HDPE / G.I. /PVC

54

674

36396

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (Minimum weight of copper earth plate plate 10.5 kg)

2

13838

27676

... More
3Ph LED Voltmeter Cl 1 (0-500V) with Inbuilt selector switch for 3 phases. Flush mounting 96 x 96 mm. (Single Function Meters. (L&T WL132010OOOO or similar in Conzerv, AE, Rishab, Secure)

1

1160

1160

... More
3 x 185 sq. mm

6

3063

18378

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

1335

368

491280

... More
3½ X 35 sq. mm

5

694

3470

... More
Push Button

6

12

72

... More
Providing and fixing following rating and breaking capacity and pole MCCB with Microprocessor release with overload, short circuit and earth fault protection and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

0.5

8340

4170.43

... More
Providing and fixing following switch gears, meters and accessories in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
200-100/5A-5A ratio, 15 VA, class 5P10 for protection

3

10906

32718

... More
3Ph LED Ammeter Cl 1 with Inbuilt selector switch for 3 phases. Flush mounting 96 x 96 mm. (Single Function Meters L&T WL131010OOOO or similar in Conzerv, AE, Rishab, Secure)

1

1160

1160

... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut,bolt, spring, washer excavation and re-filling etc. as required.

24

1551

37224

... More
100 mm dia nominal bore

6

1806

10836

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.

1

260

260.3

... More
3 x 300 sq. mm

6

4327

25962

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
250 A, 50 KA, FP MCCB, Ics= 100% of Icu

1

50980

50980

... More
3½ X 150 sq. mm (50mm)

2

697

1394

... More
CTs 250/5 A amps, 10VA with class 1.0 accuracy

3

648

1944

... More
3½ X 120 sq. mm

5

4538

22690

... More
3½ X 240 sq. mm

20

2761

55220

... More
Supplying, installation, testing and commissioning of 11 KV CT of 200/5A ratio. accuracy class 0.2S, for metering, and Resin Cast type with IS :16227 in 11 KV HT existing Metering cubicle panel, including disconnection and removal of old CT, installation of new CTs and matching the programming with the existing running system, including connection, etc as required.

3

13829

41487

... More
ADD labour cess @1 % on DSR 2022 (Elect.) amount Rs. 13,54,868/-

1

13548

13548.68

... More
Servicing and maintenance of 11 KV, 3 phase, 50 Hz Vaccum circuit breaker capacity upto 800 Amp, including disassembling the same from the H.T. Panel, complete cleaning of the components, decarbonizing the arcing chambers, replacing the minior spare parts like springs, nut bolts and washers etc, setting right the mechanism, lubricating the moving parts, checking and testing the continuity and insulation of the wiring, tightening the connections, measuring the insulation resistances with H.T. insulation tester of various points, measuring the contact resistances of moving and fixed contacts with micro ohmmeter, and rectification of faults and replacement of defective parts (If any), reassemling the breaker, testing and commissioning including dismantling & disconnection etc as per site requirement. (Any major spares, if required, will be supplied by the department.)

17

6236

106012

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :

-

-

-

... More
315 A, four Pole.

1

16990

16990

... More
250 A, 36 KA, FP MCCB, Ics= 100% of Icu

1

48391

48391

... More
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :

-

-

-

... More
50 mm dia nominal bore

6

762

4572.9

... More
Less COST INDEX on DSR(E) @ -2.73 % i.e Rs. 13,54,868/- (DSR) + 13,548.68(L/Cess) + Rs. 86,620.78 (GST difference) = Rs. 14,55,037.46/-

1

-39722

-39722.52

... More
Voltmeter /Ammeter Selector Switches

6

12

72

... More
3½ X 95 sq. mm

1

3517

3517

... More
Supply, Installation, Testing and commissioning of outdoor type totally enclosed, dust and vermin proof, pedestal mounted INSPECTION BOX / JUNCTION BOX of a suitable size but not less than 600 mm wide X 600 mm height X 500 mm (deep) fabricated from 2 mm thick CRCA sheet steel having front and back openable doors with locking arrangement on both sides, tapered top (roof), including detachable cable gland plates made of 3 mm thick CRCA sheet, including pre-paint treatment, phosphating and powder coating by approved Siemens grey paint, consisting of 300 Amps 4 strip aluminium bus bars with heat-shrinkable coloured sleeves and including DMC / SMC bus bar supports at required intervals, etc. as required, suitable for operation on 433 volts, 50 Hz, 3-phase, 4-wire A.C. supply system, the entire panel shall have one common G.I. / aluminium bar of size 25 mm x 5 mm at the rear with 2 earth studs or terminals, a danger notice plate fixed, etc., complete as required. The feeder pillar should be complete with a mounting frame made of 50 mm x 50 mm x 6 mm angle iron with 900 mm long legs. The 4 legs of the feeder pillar shall be erected on a suitable size 1:3:6 cement concrete (1:3:6 cement; 3 sand; 6 graded stones of 20 mm size) pedestal having 900mm of depth (600mm below ground and 300mm above ground).

2

15918

31836

... More
LED Indicator yellow 240V AC/24 DC. (L & T, Siemens, BCH, Telemecanique, Vaishnav, Legrand/ Kaypee)

1

153

153

... More
630 A, 50KA, FP MCCB, Ics= 100% of Icu

1

71058

71058

... More
Providing the services of service engineer for preliminary inspection and testing of the 11 kV/.433 kV transformer, 11 KV HT panel, VCB, SF6 Ring main unit, LT installation and fault detection etc. as required as per the instruction of the engineer-in-charge as and when required.

5

4112

20560

... More
3 x 240 sq. mm

6

3680

22080

... More
160 mm dia (OD-160 mm & ID-135 mm nominal)

6

361

2166

... More
Ammeter Selector Switches (ASS) 10 A.

3

364

1092

... More
Voltmeter Selector Switches (VSS) 10 A (Voltage between Phases with OFF)

3

335

1005

... More
LED Indicator Blue, 240V AC/24 DC. (L & T, Siemens, BCH, Telemecanique, Vaishnav, Legrand/ Kaypee)

1

247

247

... More
LED Indicator Blue, 240V AC/24 DC. (L & T, Siemens, BCH, Telemecanique, Vaishnav, Legrand/ Kaypee)

24

247

5928

... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

20

585

11700

... More
The road crossings of power cable through trenchless boring. Trenchless horizontal boring using Manual/ Machine Moling technique at 1.20 metre below the ground level for following size pipes, including survey of under ground utilities, excavation of pits, moling with the hole size not exceeding 20% of the pipe dia, backfilling, compaction and restoration of the pits to original condition etc. as required. The rates for moling, as indicated are inclusive of excavation of pits, backfilling, compaction and restoration of the pits to original condition. Any damages occurred to other utilities during the Moling operation shall be immediately notified and rectified by the contractor without any cost implication to the Department. The length of the Hole (excluding the sizes of the pits on both ends) shall be considered for the measurement of Moling length. However, intermediate pits will consider in the moling length. i) Upto 200 mm dia DWC HDPE / G.I. /PVC

6

1238

7428

... More
3½ X 120 sq. mm

1335

1485

1982475

... More
2 X 16 sq. mm

2

2168

4336

... More
CTs 400/5 A amps, 15VA with class 1.0 accuracy

3

631

1893

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

20

133

2674

... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required ( Zenith/TATA/Jindal-hisar/Prakash- Surya make)

-

-

-

... More
Providing and fixing Jaw contact in existing Kirloskar make Type C-500, 630 A Vaccum circuit breaker, including disassembling the same, removing old parts and assembling, testing and commissioning etc., as required.

2

5495

10990

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. [Make-Comet/Hex/Dowells/Jainson]

-

-

-

... More
Supply, installation, testing, and commissioning of a double-door, outdoor type, completely enclosed, dust and vermin proof, compartmentalized, pedestal mounted feeder pillar made of 2 mm CRCA sheet steel with fully openable front and back doors and required gaskets. The feeder pillar should have locking arrangements and a tapered top (roof), consisting of 400 Amps, 4 strip aluminium bus bars with heat-shrinkable coloured sleeves and including DMC/SMC bus bar supports at required intervals, cable alleys of suitable size, and suitable sized terminal blocks for incoming and outgoing cables, including providing and fixing interconnection from busbars to switch gears and up to terminal blocks with suitable sized solid aluminium strips and control wiring with suitable sized insulated copper conductor cable, including suitable size M.V. danger board fixed on feeder pillar, including detachable cable gland plates made of 3 mm thick CRCA sheet and powder-coated in an approved siemens grey shade after 7 tank treatment processes. The entire panel shall have one common aluminium/G.I. bar of size 25 mm x 5 mm at the rear with 2 earth studs/terminals. The feeder pillar should be complete with a mounting frame made of 50 mm x 50 mm x 6 mm angle iron with 900 mm long legs. The 4 legs of the feeder pillar shall be erected on a suitable size of 1:3:6 cement concrete (1:3:6 cement; 3 sand; 6 graded stones of 20 mm size) pedestal having 900mm of depth (600mm below ground & 300mm above ground). The feeder pillar shall have provision to accommodate the switch gears as per the item No 37 and drawing approved by the engineer-in-charge and with the required front area and a depth of a minimum of 600 mm. (drawing will be get approved before fabrication of panel)

3.52

49302

173543.04

... More
Contact block NC for Push Button

2

85

170

... More
Ammeter/ Voltmeter

1

24

24

... More
Providing and fixing Rack in & Rack out mechanism gear in existing Kirloskar make Type C-500, 630 A Vaccum circuit breaker, including disassembling the same, removing old parts and assembling, testing and commissioning etc., as required.

2

5841

11682

... More
630 A, four pole.

1

28913

28913

... More
Testing and calibration of microprocessor based numerical relay with overload, earth fault and short circuit protection relay by secondary injection method, setting of mechanism, cleaning of contacts i/c repairing, removing, & re-fixing of relays and testing of the complete tripping system by the primary & secondary injection method in all the three phases and different plug setting with suitable equipment including checking the wiring and repairing /replacement of any defective wiring if any complete etc as reqd as per terms condition & inventory.

18

2398

43164

... More
Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.

-

-

-

... More
MCB SP 6A C-Curve 10kA

3

256

768

... More
Push button for STOP . FH Red.

2

105

210

... More
3½ X 400 sq. mm

2

7966

15932

... More
3½ X 240 sq. mm

5

2933

14665

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.

-

-

-

... More
240 sq. mm

1

16249

16249

... More
4 pole, 415 V, 400 A, category AC-23A. On Load Change Over Switch, in open execution

1

24878

24878

... More
200 mm dia (OD-200 mm & ID-175 mm nominal)

6

548

3288

... More
Correction factor on existing items of DSR @0.973 as per CPWD office Memorandum 158/SE (TAS)/GST/2024/02-E DATED 8-8-2024 (U) i.e Rs. 13,54,868/- (DSR) + 13,548.68(L/Cess) + Rs. 86,620.78 (GST difference) + 41,070.40/- (DSR Civil) - 39,722.52 (Correction) = Rs. 14,56,385.34/-

1

-39322

-39322.4

... More
Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing.

-

-

-

... More
LED Indicator 240V AC/24 DC

72

12

864

... More
Checking and Testing of auxilliary relay in the HT Panel, cleaning the same with CTC solution, carrying out the secondary injection test to check the working of Bucholtz Relay, temperature alarm, high temperature trip, low oil level alarm, low oil level trip, incluing dismantling & disconnection, reinstalling etc., as per site requirement.

16

2398

38368

... More
Providing and refilling SF6 gas in RMU (up to the OEM pre scribed value) according to IEC/IS Standards relative pressure to ensure insulation and breaking functions, including repairing the steel gas tank and removing any leakage in the steel gas tank. The steel gas tank must be sealed for life and shall meet the "sealed pressure system" criteria in accord ance with the IEC 298 standard, including testing, commis sioning etc. as required .

1

17543

17543

... More
Providing and fixing following capacity 4 pole, 415 V, category AC-23A. On Load Change Over Switch, in open execution in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
CTs 200/5 A amps, 10VA with class 1.0 accuracy

3

654

1962

... More
CTs 100/5 A amps, 5VA with class 1.0 accuracy

3

631

1893

... More
3½ X 50 sq. mm

2

2478

4956

... More
3½ X 300 sq. mm

2

6107

12214

... More
3½ X 35 sq. mm

5

2478

12390

... More
Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)

0.5

1503

751.8

... More
90 mm dia (OD-90 mm & ID-76 mm nominal)

6

248

1488

... More
Supply, installation, testing, and commissioning of the following rating 11 KV CT in existing 11 KV VCB panel, including disconnection and removal of old CT, installation of new CT, including connection and matching the programming with the existing running system,etc., as required.

-

-

-

... More
Add Difference in GST of (18 & 12 %) by MF 0.0633 on DSR Elect i.e Rs. 13,54,868/- (DSR) + 13,548.68 (L/Cess) = 13,68,416.68/-

1

86620

86620.78

... More
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set, panel etc including form work etc as required.

0.2

7294

1458.94

... More
Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
250 Amps , TP, MCCB, 36 KA breaking capacity , Ics = 100% Icu with Adjustable overload and Adjustable short-circuit protection with Spreaders Terminals

2

21987

43974

... More
Providing and laying in position cement concrete of specified grade, excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (1cement: 2 coarse sand (ZONE-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size) derived from natural sources.

1

7878

7878.5

... More
Contact block for Push Button

6

12

72

... More
Servicing and maintenance 11kV VCB UNIT panel, loose connection (power & control) checking and tightening, CT & PT connection checking and tightening, bus bar connection checking and tightening, spout IR value checking and replacement if required, indication lamps are to be checked and if found faulty required to replaced, including testing of the complete system of HT panel for checking the actual working of the CTs, their wiring, connected IDMT relay, checking tripping coil of breaker and tripping supply and checking for any loose connection, checking tripping coil by primary injection method in all three phases & at each plug setting with suitable testing equipment and rectification of faults and replacement of defective parts (If any), including throughout checking/cleaning of the panel and if any hole is there then it will be closed /plugged by suitable means. Also checking IR value of PT, CT & Bulbar by suitable insulation resistance tester and to be recorded in the register. (Any major spares, if required, will be supplied by the department)

3

5277

15831

... More
90 mm dia (OD-90 mm & ID-76 mm nominal)

100

368

36800

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.

-

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

1525

42

64050

... More
Contact block NO for Push Button

2

85

170

... More
Repairing of spring charging motor in Kirloskar make Type C-500, 630 A Vaccum circuit breaker, including repair of gear set, disassembling the same and fixing after reapir, including testing and commissioning, etc., including credit for old scrap material that will be retained by the contractor, etc., complete as required.

1

11444

11444

... More
Dismantling and disconnection of the following existing meters, accessorise, etc. from the panel, including depositing it in the MMC-1 store.

-

-

-

... More
3½ X 120 sq. mm

15

1468

22020

... More
Providing services of a suitable hydraulic crane with a capacity of 10 to 12 MT for material handling, shifting, and lifting of transformers, DG sets, and other heavy machinery as and when required, including all lubricants, spare parts, consumables, fuel (Diesel), operator, maintenance staff, etc. as required

3

2741

8223

... More
300 sq. mm

1

41892

41892

... More
Fabrications, supplying and fixing of covers of the required shape and size in the existing electrical cubical panel boards/distribution boards/ feeder pillars /pole box at different locations made out from 2 mm thick CRCA sheet with locking arrangement, hinges and matching with the existing doors of the panel including painting with an approved shade of two coats of synthetic enamel paint over an undercoat of steel primer etc., complete as required.

2

7144

14288

... More
Providing and fixing Spring Charging Motor in Kirloskar make Type C-500, 630 A Vaccum circuit breaker, including disassembling the same, removing old parts and assembling, testing and commissioning etc., as required.

2

36395

72790

... More
3½ X 240 sq. mm

325

2786

905450

... More
80 mm dia nominal bore

6

1041

6250.2

... More
Bituminous portion

2

5032

10064.5

... More
3½ X 400 sq. mm

5

4429

22145

... More
160 mm dia (OD-160 mm & ID-135 mm nominal)

325

481

156325

... More
2 X 25 sq. mm

2

2478

4956

... More
Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size in the existing masonry open duct/along pole/loose for connections, etc. as required.

-

-

-

... More
3½ X 35 sq. mm (32mm)

6

369

2214

... More
Push Button for START FH Green.

2

105

210

... More
240 sq. mm

1

41892

41892

... More
3½ X 35 sq. mm

5

522

2610

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lift.

1

196

196

... More
300 sq. mm

1

16249

16249

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set, panel etc including form work etc as required.

0.2

7878

1575.7

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

12

1162

13944

... More
3½ X 185 sq. mm (57mm)

2

875

1750

... More
200 mm dia (OD-200 mm & ID-175 mm nominal)

10

668

6680

... More
3½ X 70 sq. mm

5

3363

16815

... More
Providing and fixing Vacuum Interrupter in existing Kirloskar make Type C-500, 630 A Vaccum circuit breaker, including disassembling the same, removing old parts and assembling, testing and commissioning etc., as required.

3

15837

47511

... More
3½ X 95 sq. mm (45mm)

1

588

588

... More
3½ X 185 sq. mm

2

4538

9076

... More
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

8

6855

54840

... More
LED Indicator Red, 240V AC/24 DC. (L & T, Siemens, BCH, Telemecanique, Vaishnav, Legrand/ Kaypee)

24

153

3672

... More
Preventive maintenance and inspection of a 12kV SF6-based Gas-Insulated Switchgear (GIS) Ring Main Unit (RMU) shall include thorough cleaning of dust particles, vacuum cleaning of all components (e.g., motors and mechanisms), and visual inspection. The scope also encompasses checking all hardware for tightness and proper functionality, replacing minor spare parts (e.g., nuts, bolts, washers), testing protection relays using relay testing equipment and programming, performing CT/trip coil testing, rectifying faults, and replacing defective parts, if any. Additionally, the work shall ensure proper earthing and restore the RMU to full operational status per OEM standards. The maintenance shall include Insulation Resistance (IR) Testing to measure the insulation resistance of the breaker’s components (e.g., bushings, terminals) to ground, Contact Resistance Testing, and Operation Timing Testing to measure the circuit breaker’s opening and closing times using a timing device, with results compared to the manufacturer’s specifications. The scope excludes repairing the sealed steel gas tank. (Note: Major spare parts, if required, will be supplied by the department.)

1

7127

7127

... More
Supplying and laying of G.I. pipe of 50 mm dia.(nominal), medium class, ISI marked in wall / floor including cutting chase, and making good the wall/ floor and finishing with matching surface after housing G.I. pipe in chase. ( for protection of UG cable)

6

843

5058

... More
3½ X 300 sq. mm (70mm)

2

1195

2390

... More
CTs 500/5 A amps, 15VA with class 1.0 accuracy

1

631

631

... More
3½ X 400 sq. mm

10

4282

42820

... More
125 Amps , TP, MCCB, 36 KA breaking capacity , Ics = 100% Icu with Adjustable overload and Adjustable short-circuit protection .

10

10670

106700

... More
3½ X 50 sq. mm (35mm)

2

413

826

... More
2 X 16 sq. mm (22mm)

3

256

768

... More
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

0.5

2434

1217.13

... More
3½ X 70 sq. mm (38mm)

3

468

1404

... More
3½ X 400 sq. mm (82mm)

3

1556

4668

... More
3½ X 240 sq. mm (62mm)

5

1027

5135

... More
3½ X 35 sq. mm

100

533

53300

... More
400 Amps , four pole, MCCB, 36 KA breaking capacity , Ics = 100% Icu with Microprocessor release with overload, short circuit and earth fault protection and terminal spreaders.

2

56349

112698

... More
CTs 600/5 A amps, 15VA with class 1.0 accuracy

1

631

631

... More
Providing and fixing Vacuum Housing in existing Kirloskar make Type C-500, 630 A Vaccum circuit breaker, including disassembling the same, removing old parts and assembling, testing and commissioning etc., as required.

3

10355

31065

... More
3½ X 120 sq. mm (45mm)

5

613

3065

... More
Supply, Installation, Testing and commissioning of outdoor type totally enclosed, dust and vermin proof, pedestal mounted INSPECTION BOX / JUNCTION BOX of a suitable size but not less than 700 mm wide X 700 mm height X 600 mm (deep) fabricated from 2 mm thick CRCA sheet steel having front and back openable doors with locking arrangement on both sides, tapered top (roof), including detachable cable gland plates made of 3 mm thick CRCA sheet, including pre-paint treatment, phosphating and powder coating by approved Siemens grey paint, consisting of 500 Amps 4 strip aluminium bus bars with heat-shrinkable coloured sleeves and including DMC / SMC bus bar supports at required intervals, etc. as required, suitable for operation on 433 volts, 50 Hz, 3-phase, 4-wire A.C. supply system, the entire panel shall have one common G.I. / aluminium bar of size 25 mm x 5 mm at the rear with 2 earth studs or terminals, a danger notice plate fixed, etc., complete as required. The feeder pillar should be complete with a mounting frame made of 50 mm x 50 mm x 6 mm angle iron with 900 mm long legs. The 4 legs of the feeder pillar shall be erected on a suitable size 1:3:6 cement concrete (1:3:6 cement; 3 sand; 6 graded stones of 20 mm size) pedestal having 900mm of depth (600mm below ground and 300mm above ground).

2

21640

43280

... More
400 A, 50KA, FP MCCB, Ics= 100% of Icu

1

60079

60079

... More
Providing and fixing following switch gears, meters and accessories in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required.

64

287

18368

... More
Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 11 KV (Earthed) grade Conforming to IS 7098 (Part-2) with upto date amendments of following size in the existing masonry open duct as required.

-

-

-

... More
3½ X 120 sq. mm

15

1639

24585

... More
2 X 25 sq. mm (22mm)

2

259

518

... More
300 sq. mm

1

22795

22795

... More
Lettering in Hindi/ English on L.T./ H.T. Panel/ board with synthetic enamel paint of approved brand and manufacture of the required colour etc. as required. (synthetic enamel paint : Apcolite premium enamel paint of Asian paint or a similar of Berger or Nerolac)

400

7

2800

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

6

248

1488

... More
3½ X 240 sq. mm

3

4919

14757



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.