National Security Guard Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

National Security Guard - NSG Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date31 Dec 2024
Closing Date7 Jan 2025
Tender Amount₹ 66,75,035 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and top-up transformer oil in existing transformers after filteration and Breakdown-Voltage strength test as per actual requirement of each transformer etc as required [All necessary tools, machinery spares, consumables to be provided by the contractor]

210

192

40320

... More
Providing testing of existing 630 kVA transformers for Insulation resistance [HV to Body; LV to Body & HV to LV to be checked by suitable insulation resistance tester) Magnetic Balance, Winding resistance as per relevant IS standards etc complete with standard reports as required [All necessary tools, machinery spares, consumables to be provided by the contractor]

1

5551

5551

... More
Servicing and testing LT Capacitor bank panel upto 400 kVAR including maintenance such as panel throughout checked/cleaned,all loose connection are to be checked and tightened, testing of each capacitor bank individually for efficient operation, setting of auto-control relay switch etc replacement of minor faulty accessories like nut bolts, springs, washers, connectors, sleeves/jackets, tags, and any other faulty major parts to be replaced (spare supplied by the deptt.) as per instruction of the site‐in‐charge.

2

5756

11512

... More
Testing and checking of Sandwiched type Bus bar Trunking including hot air blowing, checking of insulation (IR values), loose contacts' tightning,checking overlapping of segments, loading of mechanical supports (corrections if any) and recording of all parameters etc as required

-

-

-

... More
Above 1600A and Upto 3200Amps

2

7127

14254

... More
Servicing and maintenance of 11 KV, 3 phase, 50 Hz Vaccum circuit breaker capacity upto 800 Amp from the H.T. Panel, disassembling the same, complete cleaning of the components, decarbonizing the arcing chambers, replacing the minor spare parts like springs, nut bolts and washers etc, setting right the mechanism, lubricating the moving parts, checking and testing the continuity and insulation of the wiring, tightening the connections, measuring the insulation resistances with H.T. insulation tester of various points, measuring the contact resistances of moving and fixed contacts with micro ohmmeter, and rectification of faults and replacement of defective parts (If any), reassemling the breaker, testing and commissioning i/c dismantling & disconnection etc as per site requirement. (Any major spares, if required, shall be supplied on pro-rata bais .)

17

6236

106012

... More
Servicing and maintenance 11kV VCB UNIT panel maintenanane such as loose connection (power & control) checking and tightening, CT & PT connection checking and tightening, busbar connection checking and tightening, spout IR value checked/replaced if required , indication lamps are to be checked/replaced (Testing of the complete system of HT panel for checking the actual working of the CTs, their wiring, connected IDMT relay, tripping coil of breaker, tripping supply & for any loose connection by primary injection method in all three phases & at each plug setting with suitable testing equipment and rectification of faults and replacement of defective parts (If any), through out cheking/cleaning of the panel if any hole is there then it will be closed. Also IR value of PT, CT & Busbar checked by suitable insulation resistance tester and to be recorded in the register. (Any major spares, if required, will be supplied by the department)

4

6784

27136

... More
Checking and Testing of auxilliary relay in the HT Panel, cleaning the same with CTC solution, carrying out the secondary injection test to check the working of Bucholtz Relay, temperature alarm, high temperature trip, low oil level alarm, low oil level trip, incluing dismantling & disconnection, reinstalling etc., as per site requirement.

13

2399

31187

... More
Testing and calibration of microprocessor based numerical relay with overload, earth fault and short circuit protection relay by secondary injection method, setting of mechanism, cleaning of contacts i/c repairing, removing, & re-fixing of relays and testing of the complete tripping system by the primary & secondary injection method in all the three phases and different plug setting with suitable equipment including checking the wiring and repairing /replacement of any defective wiring if any complete etc as reqd as per terms condition & inventory.

16

2399

38384

... More
Preventive Maintenance and checking of 12KV SF6 based GIS Ring main unit (RMU) of ABB / C&S /Schnieder make comprising : thorough cleaning of dust particle, Tightness of bushings & busbars, Visual inspection, Checking of all hardware for it's tightness, replacing the minor spare parts like nut bolts and washers etc, all relay scanner checking & programming, padlocks, and rectification of faults and replacement of defective parts (If any), earthing etc., complete to set the RMU in operation as per OEM standards etc. (Any major spares, if required, will be supplied by the department.)

2

7127

14254

... More
Providing and refilling SF6 gas in RMU (up to the OEM prescribed value) according to IEC/IS Standards relative pressure to ensure insulation and breaking functions, including repairing the steel gas tank and removing any leakage in the steel gas tank. The steel gas tank must be sealed for life and shall meet the "sealed pressure system" criteria in accordance with the IEC 298 standard, including testing, commissioning etc. as required.

1

17543

17543

... More
Providing the services of service engineer for preliminary inspection and testing of the 11 kV/.433 kV transformer, 11 KV HT panel, VCB, SF6 Ring main unit, LT installation and fault detection etc. as required as per the instruction of the engineer-in-charge as and when required.

10

3426

34260

... More
Providing complete preventive maintenance, inspection and testing of 1600 KVA, 11 KV /.433 kv VOLTAMP make dry type transformers including, terminations, earthing, bushing, blower cleaning, electrical contact cleaning, removal of unwanted dust/carbon, control cables, to ensure appropriate functioning of each component of the transformer as per relevant IS norms and OEM standards to the best of it's utilisation.It includes providing any consumables necessary items during preventive maintenace such as sealents, gaskets, rubber washers, chemical cleaning agents, screws, nut-bolts, washers etc. complete as required. Testing of the transformer for insulation resistance [HV to Body; LV to Body & HV to LV to be checked by suitable insulation resistance tester) Magnetic Balance, Winding resistance as per relevant IS standards etc complete with reports in standard industrial formats to be provided as required .

-

-

-

... More
Besides carrying out the above repair and maintenance work, the contractor will provide one or more additional visits ( as reqd ) by the service engineer during the contract period for carrying out preventive maintenance of the transformer, attending to complaints and rectification of defects during any breakdown within 24 hours of the intimation. The contractor will arrange all the necessary tools and machinery for checking, repairing and maintenance of the transformer, as well as gaskets, sealants, spares, and consumables for stopping leakages and cleaning the transformer.

2

13322

26644

... More
Providing complete preventive maintenance, inspection and testing of C&S make 630 KVA, 11 KV /.433 kv VOLTAMP make dry type transformers including, terminations, earthing, bushing, blower cleaning, electrical contact cleaning, removal of unwanted dust/carbon, control cables, to ensure appropriate functioning of each component of the transformer as per relevant IS norms and OEM standards to the best of it's utilisation.It includes providing any consumables necessary during preventive maintenace such as sealents, gaskets, rubber washers, chemical cleaning agents, screws, nut-bolts, washers etc. complete as required. Testing of the transformer for insulation resistance [HV to Body; LV to Body & HV to LV to be checked by suitable insulation resistance tester) Magnetic Balance, Winding resistance as per relevant IS standards etc complete with reports in standard industrial formats to be provided as required .

-

-

-

... More
Besides carrying out the above repair and maintenance work, the contractor will provide one or more additional visits ( as reqd ) additional visits by the service engineer during the contract period for carrying out preventive maintenance of the transformer, attending to complaints and rectification of defects during any breakdown within 24 hours of the intimation. The contractor will arrange all the necessary tools and machinery for checking, repairing and maintenance of the transformer, as well as gaskets, sealants, spares, and consumables for stopping leakages and cleaning the transformer.

1

7538

7538

... More
Providing and fixing following rating and breaking capacity and pole MCCB with Thermo-magnetic release with overload, short circuit and earth fault protection and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
250 A, 36 KA, FP MCCB, Ics= 100% of Icu

1

28277

28277

... More
250 A, 50 KA, FP MCCB, Ics= 100% of Icu

1

31932

31932

... More
400 A, 50KA, FP MCCB, Ics= 100% of Icu

1

37057

37057

... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
3½ X 95 sq. mm

2

3517

7034

... More
3½ X 120 sq. mm

2

4538

9076

... More
3½ X 150 sq. mm

2

4538

9076

... More
3½ X 185 sq. mm

1

4538

4538

... More
3½ X 240 sq. mm

1

4919

4919

... More
3½ X 300 sq. mm

1

6107

6107

... More
3½ X 400 sq. mm

1

7966

7966

... More
Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 11 KV (Earthed) grade Conforming to IS 7098 (Part-2) with upto date amendments of following size in the existing masonry open duct as required.

-

-

-

... More
3 x 185 sq. mm

10

3058

30580

... More
3 x 240 sq. mm

10

3676

36760

... More
3 x 300 sq. mm

10

4322

43220

... More
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :

-

-

-

... More
185sq. mm

2

31096

62192

... More
240 sq. mm

2

41892

83784

... More
300 sq. mm

2

41892

83784

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required

-

-

-

... More
185 sq. mm

1

11329

11329

... More
240 sq. mm

1

16249

16249

... More
300 sq. mm

1

16249

16249

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :

-

-

-

... More
185 sq. mm

1

14575

14575

... More
240 sq. mm

1

22795

22795

... More
300 sq. mm

1

22795

22795

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

7472

29888

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

30

706

21180

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

30

244

7320

... More
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

6

6855

41130

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required.

60

287

17220

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

4260

42

178920

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

2

13838

27676

... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.

15

1551

23265

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

15

1162

17430

... More
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.

1

2113

2113

... More
Location, tracing and pin-pointing of faults in existing 1.1 KV and 11KV grade underground cables, including disconnection of the cable at both ends, finding the route of the cable, excavation at the fault point to make the fault point visible, making temporary joints ( in case of LT cable), testing the cable on load for three hours, including refilling the excavated trench and cleaning the site, etc. as required(Permamnent joints will be paid separately ).

10

10162

101620

... More
Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
3½ X 240 sq. mm

730

2780

2029400

... More
3½ X 300 sq. mm

250

3383

845750

... More
3½ X 400 sq. mm

300

4276

1282800

... More
Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size in the existing masonry open duct/along pole/loose for connections, etc. as required.

-

-

-

... More
3½ X 240 sq. mm

40

2756

110240

... More
3½ X 300 sq. mm

15

3359

50385

... More
3½ X 400 sq. mm

15

4252

63780

... More
The road crossings of power cable through trenchless boring. Trenchless horizontal boring using Manual/ Machine Moling technique at 0.75 metre below the ground level for following size pipes, including survey of under ground utilities, excavation of pits, moling with the hole size not exceeding 20% of the pipe dia, backfilling, compaction and restoration of the pits to original condition etc. as required. The rates for moling, as indicated are inclusive of excavation of pits, backfilling, compaction and restoration of the pits to original condition. Any damages occurred to other utilities during the Moling operation shall be immediately notified and rectified by the contractor without any cost implication to the Department. The length of the Hole (excluding the sizes of the pits on both ends) shall be considered for the measurement of Moling length. However, intermediate pits will consider in the moling length. i) Upto 200 mm dia DWC HDPE / G.I. /PVC

60

651

39060

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.

-

-

-

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

60

248

14880

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

1280

368

471040

... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required ( Zenith/TATA/Jindal-hisar/Prakash- Surya make)

-

-

-

... More
100 mm dia

5

1806

9030

... More
150 mm dia nominal bore

10

2740

27400

... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription (as per engineer-in-charge) duly engraved as required.

30

585

17550

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. [Make-Comet/Hex/Dowells/Jainson]

-

-

-

... More
3 X 95 sq. mm (38mm)

2

542

1084

... More
3½ X 120 sq. mm (45mm)

2

597

1194

... More
3½ X 150 sq. mm (50mm)

2

681

1362

... More
3½ X 240 sq. mm (62mm)

8

1027

8216

... More
3½ X 300 sq. mm (62mm)

4

1195

4780

... More
3½ X 400 sq. mm (82mm)

2

1556

3112

... More
Providing programming of existing SIEMENS make PLC unit installed in PCC panel in new-substation building at Shekhawat Complex, i/c testing & commissioning of complete PCC panel on programmed PLC etc complete as required.

1

13706

13706

... More
Providing and fixing following capacity 4 pole, 415 V, category AC-23A. On Load Change Over Switch, in open execution in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. ( Make:- L& T /Socomec / Legrand /ABB /Schneider/ Siemen)

-

-

-

... More
315 A, four Pole.

1

18586

18586

... More
Supply, Installation, Testing and commissioning of outdoor type totally enclosed, dust and vermin proof, pedestal mounted INSPECTION BOX / JUNCTION BOX of a suitable size but not less than 600 mm wide X 600 mm height X 450 mm (deep) fabricated from 2 mm thick CRCA sheet steel having front and back openable doors with locking arrangement on both sides, tapered top (roof), including detachable cable gland plates made of 3 mm thick CRCA sheet, including pre-paint treatment, phosphating and powder coating by approved Siemens grey paint, consisting of 500 Amps 4 strip aluminium bus bars with heat-shrinkable coloured sleeves and including DMC / SMC bus bar supports at required intervals, etc. as required

-

-

-

... More
suitable for operation on 433 volts, 50 Hz, 3-phase, 4-wire A.C. supply system, the entire panel shall have one common G.I. bar of size 25 mm x 5 mm at the rear with 2 earth studs or terminals, a danger notice plate fixed, etc., complete as required. The feeder pillar should be complete with a mounting frame made of 50 mm x 50 mm x 6 mm angle iron with 900 mm long legs. The 4 legs of the feeder pillar shall be erected on a suitable size 1:3:6 cement concrete (1:3:6 cement; 3 sand; 6 graded stones of 20 mm size) pedestal having 900mm of depth (600mm below ground and 300mm above ground)..

1

23232

23232

... More
Providing services of a suitable hydraulic crane with a capacity of 10 to 12 MT for material handling, shifting, and lifting of transformers, DG sets, and other heavy machinery as and when required, including all lubricants, spare parts, consumables, fuel (Diesel), operator, maintenance staff, etc. as required

5

2741

13705

... More
Lettering in Hindi/ English on L.T./ H.T. Panel/ board with synthetic enamel paint of approved brand and manufacture of the required colour etc. as required. (synthetic enamel paint : Apcolite premium enamel paint of Asian paint or a similar of Berger or Nerolac)

1000

6

6000

... More
Fabrication Supplying , Installation , testing and commissioning of LED based outdoor type display signage board in English/Hindi language and as per approved colour & design with router cutting of letters on 3 mm ACP and the pipe frame having depth of 2" . The pipe frame shall be covered from the back and side with 24 SWG GI Sheet and the front facia shall be covered by the ACP sheet fixed on the MS square pipe section with stiffners welded vertically and horizontally in the regular interval i.e. providing inside the letter LED Source OSRAM/GE/Samsung LED Modules on 5 Years Warranty & Water Proof Power Supply on 2 Years Warranty . The finished letter and other accessories to be fixed on aluminium composit panel (ACP) of 3 mm thick i/c wiring the entire board with power cables suitable for out door grade etc as required.

80

1860

148800

... More
ADD labour cess @1 % on DSR 2022 (Elect.) amount Rs. 12,20,162/-

1

12201

12201.62

... More
Add Difference in GST of (18 &12 %) by MF 0.0633 on DSR Elect i.e Rs. 12,20,162/- (DSR) + 12,201.62 (L/Cess) = 12,32,363.62/-

1

78008

78008.62

... More
Less COST INDEX on DSR(E) @ -2.73 % i.e Rs. 12,20,162/- (DSR) + 12,201.62(L/Cess) + Rs. 78,008.62 (GST difference) = Rs. 13,10,372.24/-

1

-35773

-35773.16

... More
Correction factor on existing items of DSR @0.973 as per CPWD office Memorandum 158/SE (TAS)/GST/2024/02-E DATED 8-8-2024 (U) i.e Rs. 12,20,162/- (DSR) + 12,201.62(L/Cess) + Rs. 78,008.62(GST difference) + 0.00 (DSR Civil) - 35,773.16 (Correction) = Rs. 12,74,599.08/-

1

-34414

-34414.18



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.