If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

National Security Guard - NSG Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date9 Sep 2023
Closing Date19 Sep 2023
Tender Amount₹ 63,34,411 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and replacing glass cover in conservator tank oil level indicator including gaskets, accessories etc as required [All necessary tools, machinery spares, consumables to be provided by the contractor]

4

9016

2254

... More
Providing and replacing silica gel breather with oil cup containing 1 kg of silica gel (as per IS: 3401-1992) on existing 11/0.433kV transformers etc. as required. [All necessary tools, machinery spares, consumables to be provided by the contractor]

6

10140

1690

... More
Providing and replacing silica gel breather with oil cup containing 1/2 kg of silica gel (as per IS: 3401-1992) on existing 11/0.433kV transformers etc. as required. [All necessary tools, machinery spares, consumables to be provided by the contractor]

4

3728

932

... More
Providing testing of existing 11/0.433kV, 500 kva/ 800kva/ 1000kva transformers for Insulation resistance [HV to Body; LV to Body & HV to LV to be checked by suitable insulation resistance tester) Magnetic Balance, Winding resistance as per relevant IS standards etc complete with standard reports as required [All necessary tools, machinery spares, consumables to be provided by the contractor]

10

50710

5071

... More
Servicing and maintenance of the Air Circuit breaker/bus coupler of following ratings 3p/4p, 415V, 50 Hz from the MV Panel, cleaning the same, disassemling, decarbonizing the arching contacts & arcing chutes completely, cleaning the fixed and moving contacts with ctc, checking the control wiring for continuity, tightening the connections, replacement of minor parts like spring, nut bolts and washers, setting right the mechanism, lubricating the moving mechanical parts, measuring the contact resistance of fixed and moving contacts with Micro ohm meter, and rectification of faults and replacement of defective parts (If any), reassemling the ACB, checking and testing the tripping system and releases with the help of secondary injection test kit at minimum three settings of over current, earth fault current, reinstallation the ACB in MV Panel, commissioning i/c dismantling & disconnection etc as reqd. (Any major spares, if required, will be supplied by the department.)

-

-

-

... More
Above 800A and Upto 1600Amps

17

86207

5071

... More
Testing and checking of Bus bar Trunking including hot air blowing, chekcing of insulation (IR values), loose contacts' tightning,checking overlapping of segments, loading of mechanical supports (corrections if any) and recording of all parameters etc as required.

-

-

-

... More
Up to 800 A

4

22536

5634

... More
Above 800A and Upto 1600Amps

6

42258

7043

... More
Servicing and maintenance of 11 KV, 3 phase, 50 Hz Vaccum circuit breaker capacity upto 800 Amp from the H.T. Panel, disassembling the same, complete cleaning of the components, decarbonizing the arcing chambers, replacing the minior spare parts like springs, nut bolts and washers etc, setting right the mechanism, lubricating the moving parts, checking and testing the continuity and insulation of the wiring, tightening the connections, measuring the insulation resistances with H.T. insulation tester of various points, measuring the contact resistances of moving and fixed contacts with micro ohmmeter, and rectification of faults and replacement of defective parts (If any), reassemling the breaker, testing and commissioning /c dismantling & disconnection etc as per site requirement. (Any major spares, if required, will be supplied by the department.)

17

108953

6409

... More
Servicing and maintenance of 11kV, 400 Amp, 3 phase, 50 Hz Oil circuit breaker from the H.T. Panel, disassembling the same, complete cleaning of the components, decarbonizing the arcing chambers, replacing the minor spare parts like springs.nut bolts and washers etc, setting right the mechanism, lubricating the moving parts,checking and testing the continuity and insulation of the wiring, tightening the connections, measuring the insulation resistances with H.T.insulation tester of various points, measuring the contact resistances of moving and fixed contacts with micro ohmmeter, reassemling the breaker, and rectification of faults and replacement of defective parts (If any), testing and commissioning i/c dismantling & disconnection etc as per site requirement. (Any major spares, if required, will be supplied by the department.)

3

19227

6409

... More
Servicing and maintenance 11kV VCB UNIT panel maintenanane such as loose connection (power & control) checking and tightening, CT & PT connection checking and tightening, busbar connection checking and tightening, spout IR value checked/replaced if required , indication lamps are to be checked/replaced (Testing of the complete system of HT panel for checking the actual working of the CTs, their wiring, connected IDMT relay, tripping coil of breaker, tripping supply & for any loose connection by primary injection method in all three phases & at each plug setting with suitable testing equipment and rectification of faults and replacement of defective parts (If any), through out cheking/cleaning of the panel if any hole is there then it will be closed. Also IR value of PT, CT & Busbar checked by suitable insulation resistance tester and to be recorded in the register. (Any major spares, if required, will be supplied by the department)

3

16269

5423

... More
Servicing and maintenance 11kV OCB UNIT panel maintenanane such as loose connection (power & control) checking and tightening, CT & PT connection checking and tightening, busbar connection checking and tightening, spout IR value checked/replaced if required , indication lamps are to be checked/replaced (Testing of the complete system of HT panel for checking the actual working of the CTs, their wiring, connected IDMT relay, tripping coil of breaker, tripping supply & for any loose connection by primary injection method in all three phases & at each plug setting with suitable testing equipment and rectification of faults and replacement of defective parts (If any), through out cheking/cleaning of the panel if any hole is there then it will be closed. Also IR value of PT, CT & Busbar checked by suitable insulation resistance tester and to be recorded in the register. (Any major spares, if required, will be supplied by the department)

1

5423

5423

... More
Checking and Testing of auxilliary relay in the HT Panel, cleaning the same with CTC solution, carrying out the secondary injection test to check the working of Bucholtz Relay, temperature alarm, high temperature trip, low oil level alarm, low oil level trip, incluing dismantling & disconnection, reinstalling etc., as per site requirement.

10

24650

2465

... More
Testing and calibration of microprocessor based numerical relay with overload, earth fault and short circuit protection relay by secondary injection method, setting of mechanism, cleaning of contacts i/c repairing, removing, & re-fixing of relays and testing of the complete tripping system by the primary & secondary injection method in all the three phases and different plug setting with suitable equipment including checking the wiring and repairing /replacement of any defective wiring if any complete etc as reqd as per terms condition & inventory.

17

41905

2465

... More
Preventive Maintenance and checking of 12KV SF6 based GIS Ring main unit (RMU) of ABB / C&S /Schnieder make comprising : thorough cleaning of dust particle, Tightness of bushings & busbars, Visual inspection, Checking of all hardware for it's tightness, replacing the minor spare parts like nut bolts and washers etc, all relay scanner checking & programming, padlocks, and rectification of faults and replacement of defective parts (If any), earthing etc., complete to set the RMU in operation as per OEM standards etc. (Any major spares, if required, will be supplied by the department.)

1

7324

7324

... More
Providing and refilling SF6 gas in RMU (up to the OEM prescribed value) according to IEC/IS Standards relative pressure to ensure insulation and breaking functions, including repairing the steel gas tank and removing any leakage in the steel gas tank. The steel gas tank must be sealed for life and shall meet the "sealed pressure system" criteria in accordance with the IEC 298 standard, including testing, commissioning etc. as required.

1

18029

18029

... More
Providing the services of service engineer for preliminary inspection and testing of the 11 kV/.433 kV transformer, 11 KV HT panel, VCB, SF6 Ring main unit, LT installation and fault detection etc. as required as per the instruction of the engineer-in-charge as and when required.

10

42260

4226

... More
Providing and fixing following rating and breaking capacity and pole MCCB with Microprocessor release with overload, short circuit and earth fault protection and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
250 A, 36 KA, FP MCCB, Ics= 100% of Icu

2

89646

44823

... More
250 A, 50 KA, FP MCCB, Ics= 100% of Icu

1

47210

47210

... More
400 A, 50KA, FP MCCB, Ics= 100% of Icu

1

56169

56169

... More
630 A, 50KA, FP MCCB, Ics= 100% of Icu

2

132814

66407

... More
Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 11 KV (Earthed) grade Conforming to IS 7098 (Part-2) with upto date amendments of following size in the existing masonry open duct as required.

-

-

-

... More
3 x 185 sq. mm

6

15774

2629

... More
3 x 240 sq. mm

6

18864

3144

... More
3 x 300 sq. mm

6

22176

3696

... More
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :

-

-

-

... More
240 sq. mm

1

41892

41892

... More
300 sq. mm

1

41892

41892

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required

-

-

-

... More
240 sq. mm

1

16249

16249

... More
300 sq. mm

1

16249

16249

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :

-

-

-

... More
240 sq. mm

1

22795

22795

... More
300 sq. mm

1

22795

22795

... More
Fabrications, supplying and fixing of covers of the required shape and size in the existing electrical cubical panel boards/distribution boards/ feeder pillars /pole box at different locations made out from 2 mm thick CRCA sheet with locking arrangement, hinges and matching with the existing doors of the panel including painting with an approved shade of two coats of synthetic enamel paint over an undercoat of steel primer etc., complete as required.

2

14040

7020

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (Minimum weight of copper earth plate plate 10.5 kg)

18

249084

13838

... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut,bolt, spring, washer excavation and re-filling etc. as required.

72

111672

1551

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

90

104580

1162

... More
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

4

27420

6855

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required.

8

2296

287

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

1556

65352

42

... More
Location, tracing and pin-pointing of faults in existing 1.1 KV and 11KV grade underground cables, including disconnection of the cable at both ends, finding the route of the cable, excavation at the fault point to make the fault point visible, making temporary joints ( in case of LT cable), testing the cable on load for three hours, including refilling the excavated trench and cleaning the site, etc. as required(Permamnent joints will be paid separately ).

10

100310

10031

... More
Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.

-

-

-

... More
3½ X 240 sq. mm

5

12545

2509

... More
3½ X 400 sq. mm

10

37450

3745

... More
Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
3½ X 240 sq. mm

48

113232

2359

... More
3½ X 400 sq. mm

680

2444600

3595

... More
Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of following size in the existing masonry open duct/along pole/loose for connections, etc. as required.

-

-

-

... More
3½ X 240 sq. mm

5

11680

2336

... More
3½ X 400 sq. mm

30

107160

3572

... More
The road crossings of power cable through trenchless boring. Trenchless horizontal boring using Manual/ Machine Moling technique at 0.75 metre below the ground level for following size pipes, including survey of under ground utilities, excavation of pits, moling with the hole size not exceeding 20% of the pipe dia, backfilling, compaction and restoration of the pits to original condition etc. as required. The rates for moling, as indicated are inclusive of excavation of pits, backfilling, compaction and restoration of the pits to original condition. Any damages occurred to other utilities during the Moling operation shall be immediately notified and rectified by the contractor without any cost implication to the Department. The length of the Hole (excluding the sizes of the pits on both ends) shall be considered for the measurement of Moling length. However, intermediate pits will consider in the moling length. i) Upto 200 mm dia DWC HDPE / G.I. /PVC

45

28485

633

... More
The road crossings of power cable through trenchless boring. Trenchless horizontal boring using Manual/ Machine Moling technique at 1.20 metre below the ground level for following size pipes, including survey of under ground utilities, excavation of pits, moling with the hole size not exceeding 20% of the pipe dia, backfilling, compaction and restoration of the pits to original condition etc. as required. The rates for moling, as indicated are inclusive of excavation of pits, backfilling, compaction and restoration of the pits to original condition. Any damages occurred to other utilities during the Moling operation shall be immediately notified and rectified by the contractor without any cost implication to the Department. The length of the Hole (excluding the sizes of the pits on both ends) shall be considered for the measurement of Moling length. However, intermediate pits will consider in the moling length. i) Upto 200 mm dia DWC HDPE / G.I. /PVC

10

11630

1163

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.

-

-

-

... More
160 mm dia (OD-160 mm & ID-135 mm nominal)

6

2166

361

... More
200 mm dia (OD-200 mm & ID-175 mm nominal)

6

3288

548

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
160 mm dia (OD-160 mm & ID-135 mm nominal)

40

19240

481

... More
200 mm dia (OD-200 mm & ID-175 mm nominal)

680

454240

668

... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required ( Zenith/TATA/Jindal-hisar/Prakash- Surya make)

-

-

-

... More
50 mm dia nominal bore

6

3925

654.2

... More
80 mm dia nominal bore

6

5514

919.1

... More
100 mm dia nominal bore

6

10836

1806

... More
150 mm dia nominal bore

36

98640

2740

... More
Supplying and laying of G.I. pipe of 50 mm dia.(nominal), medium class, ISI marked in wall / floor including cutting chase, and making good the wall/ floor and finishing with matching surface after housing G.I. pipe in chase. ( for protection of UG cable)

6

4962

827

... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

20

11700

585

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. [Make-Comet/Hex/Dowells/Jainson]

-

-

-

... More
3½ X 240 sq. mm (62mm)

2

2054

1027

... More
3½ X 400 sq. mm (82mm)

8

12448

1556

... More
Supply, installation, testing, and commissioning of a double-door, outdoor type, completely enclosed, dust and vermin proof, compartmentalized, pedestal mounted feeder pillar made of 2 mm CRCA sheet steel with fully openable front and back doors and required gaskets. The feeder pillar should have locking arrangements and a tapered top (roof), consisting of 400 Amps, 4 strip aluminium bus bars with heat-shrinkable coloured sleeves and including DMC/SMC bus bar supports at required intervals, cable alleys of suitable size, and suitable sized terminal blocks for incoming and outgoing cables, including providing and fixing interconnection from busbars to switch gears and up to terminal blocks with suitable sized solid aluminium strips and control wiring with suitable sized insulated copper conductor cable, including suitable size M.V. danger board fixed on feeder pillar, including detachable cable gland plates made of 3 mm thick CRCA sheet and powder-coated in an approved siemens grey shade after 7 tank treatment processes. The entire panel shall have one common aluminium/G.I. bar of size 25 mm x 5 mm at the rear with 2 earth studs/terminals. The feeder pillar should be complete with a mounting frame made of 50 mm x 50 mm x 6 mm angle iron with 900 mm long legs. The 4 legs of the feeder pillar shall be erected on a suitable size of 1:3:6 cement concrete (1:3:6 cement; 3 sand; 6 graded stones of 20 mm size) pedestal having 900mm of depth (600mm below ground & 300mm above ground). The feeder pillar shall have provision to accommodate the switch gears as per the item No 44 and drawing approved by the engineer-in-charge and with the required front area and a depth of a minimum of 600 mm. (drawing will be get approved before fabrication of panel)

3.52

178354

50669

... More
Providing and fixing following switch gears, meters and accessories in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
400 Amps , four pole, MCCB, 36 KA breaking capacity , Ics = 100% Icu with Microprocessor release with overload, short circuit and earth fault protection and terminal spreaders.

2

105508

52754

... More
4 pole, 415 V, 400 A, category AC-23A. On Load Change Over Switch, in open execution

1

23886

23886

... More
250 Amps , TP, MCCB, 36 KA breaking capacity , Ics = 100% Icu with Adjustable overload and Adjustable short-circuit protection with Spreaders Terminals

2

40706

20353

... More
125 Amps , TP, MCCB, 36 KA breaking capacity , Ics = 100% Icu with Adjustable overload and Adjustable short-circuit protection .

10

100570

10057

... More
3 ph Multifunction meter for the measurement of parameters voltage, current, power factor, frequency, KW and KWH Flush mounting type.

1

4294

4294

... More
CTs 400/5 A amps, 15VA with class 1.0 accuracy

3

1920

640

... More
LED Indicator Red, 240V AC/ 24 DC. (L & T, Siemens, BCH, Telemecanique, Vaishnav, Legrand/ Kaypee)

1

150

150

... More
LED Indicator yellow 240V AC/24 DC. (L & T, Siemens, BCH, Telemecanique, Vaishnav, Legrand/ Kaypee)

1

150

150

... More
LED Indicator Blue, 240V AC/24 DC. (L & T, Siemens, BCH, Telemecanique, Vaishnav, Legrand/ Kaypee)

1

241

241

... More
MCB SP 6A C-Curve 10KA

3

768

256

... More
Providing and fixing following switch gears, meters and accessories in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
3Ph LED Ammeter Cl 1 with Inbuilt selector switch for 3 phases. Flush mounting 96 x 96 mm. (Single Function Meters L&T WL131010OOOO or similar in Conzerv, AE, Rishab, Secure)

1

1480

1480

... More
3Ph LED Voltmeter Cl 1 (0-500V) with Inbuilt selector switch for 3 phases. Flush mounting 96 x 96 mm. (Single Function Meters. (L&T WL132010OOOO or similar in Conzerv, AE, Rishab, Secure)

1

1480

1480

... More
CTs 100/5 A amps, 5VA with class 1.0 accuracy

3

1920

640

... More
CTs 200/5 A amps, 10VA with class 1.0 accuracy

3

1992

664

... More
CTs 250/5 A amps, 10VA with class 1.0 accuracy

3

2202

734

... More
CTs 500/5 A amps, 15VA with class 1.0 accuracy

3

1920

640

... More
CTs 600/5 A amps, 15VA with class 1.0 accuracy

3

1920

640

... More
LED Indicator Red, 240V AC/ 24 DC. (L & T, Siemens, BCH, Telemecanique, Vaishnav, Legrand/ Kaypee)

24

3600

150

... More
LED Indicator Red, 240V AC/24 DC. (L & T, Siemens, BCH, Telemecanique, Vaishnav, Legrand/ Kaypee)

24

3600

150

... More
LED Indicator Blue, 240V AC/24 DC. (L & T, Siemens, BCH, Telemecanique, Vaishnav, Legrand/ Kaypee)

24

5784

241

... More
Panel Mounted Buzzer Ø 22.5 mm. (L & T, Siemens, BCH, Telemecanique, Vaishnav, Kaypee)

1

308

308

... More
Ammeter Selector Switches (ASS) 10 A.

3

1050

350

... More
Voltmeter Selector Switches (VSS) 10 A (Voltage between Phases with OFF)

3

960

320

... More
Push Button for START FH Green.

2

202

101

... More
Push button for STOP . FH Red.

2

202

101

... More
Contact block NO for Push Button

2

166

83

... More
Contact block NC for Push Button

2

166

83

... More
Providing and fixing 3 Phase Over Current and Earth Fault Numerical Relay in existing HT panel board including drilling holes in cubicle panel, making connections, testing etc. as required. (AVANA NPA-422 or similar in /ABB /AREVA / SIEMENS/ L&T)

1

22341

22341

... More
Providing and fixing following capacity 4 pole, 415 V, category AC-23A. On Load Change Over Switch, in open execution in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
315 A, four Pole.

1

16298

16298

... More
630 A, four pole.

1

27790

27790

... More
Supply, Installation, Testing and commissioning of outdoor type totally enclosed, dust and vermin proof, pedestal mounted INSPECTION BOX / JUNCTION BOX of a suitable size but not less than 600 mm wide X 600 mm height X 500 mm (deep) fabricated from 2 mm thick CRCA sheet steel having front and back openable doors with locking arrangement on both sides, tapered top (roof), including detachable cable gland plates made of 3 mm thick CRCA sheet, including pre-paint treatment, phosphating and powder coating by approved Siemens grey paint, consisting of 300 Amps 4 strip aluminium bus bars with heat-shrinkable coloured sleeves and including DMC / SMC bus bar supports at required intervals, etc. as required, suitable for operation on 433 volts, 50 Hz, 3-phase, 4-wire A.C. supply system, the entire panel shall have one common G.I. / aluminium bar of size 25 mm x 5 mm at the rear with 2 earth studs or terminals, a danger notice plate fixed, etc., complete as required. The feeder pillar should be complete with a mounting frame made of 50 mm x 50 mm x 6 mm angle iron with 900 mm long legs. The 4 legs of the feeder pillar shall be erected on a suitable size 1:3:6 cement concrete (1:3:6 cement; 3 sand; 6 graded stones of 20 mm size) pedestal having 900mm of depth (600mm below ground and 300mm above ground).

3

49077

16359

... More
Supply, Installation, Testing and commissioning of outdoor type totally enclosed, dust and vermin proof, pedestal mounted INSPECTION BOX / JUNCTION BOX of a suitable size but not less than 700 mm wide X 700 mm height X 600 mm (deep) fabricated from 2 mm thick CRCA sheet steel having front and back openable doors with locking arrangement on both sides, tapered top (roof), including detachable cable gland plates made of 3 mm thick CRCA sheet, including pre-paint treatment, phosphating and powder coating by approved Siemens grey paint, consisting of 500 Amps 4 strip aluminium bus bars with heat-shrinkable coloured sleeves and including DMC / SMC bus bar supports at required intervals, etc. as required, suitable for operation on 433 volts, 50 Hz, 3-phase, 4-wire A.C. supply system, the entire panel shall have one common G.I. / aluminium bar of size 25 mm x 5 mm at the rear with 2 earth studs or terminals, a danger notice plate fixed, etc., complete as required. The feeder pillar should be complete with a mounting frame made of 50 mm x 50 mm x 6 mm angle iron with 900 mm long legs. The 4 legs of the feeder pillar shall be erected on a suitable size 1:3:6 cement concrete (1:3:6 cement; 3 sand; 6 graded stones of 20 mm size) pedestal having 900mm of depth (600mm below ground and 300mm above ground).

1

22240

22240

... More
Providing services of a suitable hydraulic crane with a capacity of 10 to 12 MT for material handling, shifting, and lifting of transformers, DG sets, and other heavy machinery as and when required, including all lubricants, spare parts, consumables, fuel (Diesel), operator, maintenance staff, etc. as required

5

14085

2817

... More
Providing and fixing one 11 kV/0.433 kV, 800 KVA to 1000 KVA, three-phase, reputed make copper-wound oil-immersed/ dry transformer on a rental basis at Sub-station NSG campus Manesar, including loading and unloading of the transformer at NSG Campus Manesar and the workshop, and transformer transportation to and fro the workshop to NSG Campus Manesar. The contractor shall have to provide a duly tested and fully operational transformer conforming to the relevant I.S. specifications. If the transformer malfunctions at the site, it will be replaced immediately, for which no extra payment will be made. The transformer will be kept in excellent working condition throughout the hiring period, and the contractor will bear all maintenance and repair costs, including spare parts, consumables, etc., of the hired transformer, and nothing extra will be paid on this account.

30

74640

2488

... More
Providing and fixing Vacuum Interrupter in existing Kirloskar make Type C-500, 630 A Vaccum circuit breaker, including disassembling the same, removing old parts and assembling, testing and commissioning etc., as required.

3

48537

16179

... More
Providing and fixing Vacuum Housing in existing Kirloskar make Type C-500, 630 A Vaccum circuit breaker, including disassembling the same, removing old parts and assembling, testing and commissioning etc., as required.

3

31632

10544

... More
Providing and fixing Spring Charging Motor in Kirloskar make Type C-500, 630 A Vaccum circuit breaker, including disassembling the same, removing old parts and assembling, testing and commissioning etc., as required.

1

37307

37307

... More
Supply, installation, testing, and commissioning of the following rating 11 KV CT in existing 11 KV VCB panel, including disconnection and removal of old CT, installation of new CT, including connection and matching the programming with the existing running system,etc., as required.

-

-

-

... More
200-100/5A-5A ratio, 15 VA, class 5P10 for protection

3

33291

11097

... More
Supplying, installation, testing and commissioning of 11 KV CT of 200/5A ratio. accuracy class 0.2S, for metering, and Resin Cast type with IS :16227 in 11 KV HT existing Metering cubicle panel, including disconnection and removal of old CT, installation of new CTs and matching the programming with the existing running system, including connection, etc as required.

3

42216

14072

... More
Lettering in Hindi/ English on L.T./ H.T. Panel/ board with synthetic enamel paint of approved brand and manufacture of the required colour etc. as required. (synthetic enamel paint : Apcolite premium enamel paint of Asian paint or a similar of Berger or Nerolac)

400

2400

6

... More
Providing and laying in position cement concrete 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) for the repair of the road after cutting of road for cable repair and laying.

1

7365

7365.15

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

50

3910

78.2

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.

-

-

-

... More
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

2

4014

2007.1

... More
Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)

4

4958

1239.6

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set, panel etc including form work etc as required.

0.2

1473

7365.15

... More
Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing.

-

-

-

... More
1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

0.5

3891

7783.65

... More
Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.

-

-

-

... More
Bituminous portion

2

8315

4157.85

... More
Dismantling and disconnection of the following existing meters, accessorise, etc. from the panel, including depositing it in the MMC-1 store.

-

-

-

... More
Ammeter/ Voltmeter

1

23

23

... More
LED Indicator 240V AC/24 DC

72

864

12

... More
Voltmeter /Ammeter Selector Switches

6

72

12

... More
Push Button

6

72

12

... More
Contact block for Push Button

6

72

12

... More
CTs 100/5 A, to 600/5A amps 415 volt.

9

207

23

... More
Add 1.0633 multiplying factor for GST on DSR

1

87418

87418.83



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.