National Security Guard Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

National Security Guard - NSG Tender

Works
Electrical and Electronics
Eprocure
Opening Date2 Dec 2019
Closing Date11 Dec 2019
Tender Amount₹ 54,10,965 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
VRF System shall be suitable for working on Ambient Temperature, with Refrigerant R-410A. Unit price shall be inclusive of full charge of Refrigerant Gas & Oil, Freight, Insurance, all Taxes & Duties etc. as applicable In INR. All inter-connecting piping, joints and U bends within the condensing unit shall be painted with two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution before installation. Make- Hitachi, O General, Mitsubishi, Toshiba, Carrier, Diakin (Manufacture Company)

-

-

-

... More
OUTDOOR UNITS VRF TYPE

-

-

-

... More
(24 HP) (1 Working )

1

-

460000

... More
40 HP (20+20 HP) (1 Working +1 Standby)

1

-

898000

... More
INDOOR UNITS AHU TYPE WITH VRF

-

-

-

... More
Supply, installation,testing and commissioning of double skin, double deck typeceiling suspended ahu , 43 mm thick PUF insulated air handling unit comprising of mixing box, prefilter section with 10 micron filters, freesh air / return air/ bleed air / coil bypass / supply air dampers, cooling coil section with min.4 row cooling coil, SS 304 insulated drain pan, Fan + motor section with Fan, Motor, drive package (as per specification/drawing) vibration isolators and other accessories as required to complete the installation, fine filter section with 5 micron filters, air discharge plenum. All the AHUs shall include D.O.L/Star-delta starter (upto 7.5HP DOL, above 7.5HP star delta), AHU starter panel to included starter for heaters, humidifiers, etc., as per connected load as indicated in the Heat load summaary sheet. Fresh air for all AHUs mentioned here under will be 5 ACPH of specified room volume and coils to be sized accordingly and all AHUs to be controlled with OT (control panel) remote controller, the quote should include complete with suitable DOL / Star Delta Electrical Panle, 15 RMT suitable electrical cabling, Earthing, control cabling etc., in total to make complete set AHU smooth operation Client will Provide single point 3 phase power supply at AHU starter panel location. Total Static pressure of the below ahus to be considered as 125mm. All 3-phase Unit shall be installed along with starter panel as per the description metioned below: All AHUs to be sized for 10% more CFM than specified below. (Suitable for Out door installation). All AHUs shall be BMS compatible.

-

-

-

... More
Static Presser 100-125

-

-

-

... More
SURGICAL -OT - 6.0 TR/3000CFM

1

-

265000

... More
MAIN- OT - 5.0 TR/ 2400 CFM

1

-

245000

... More
Minor OT - 3.0 TR / 1700 CFM

1

-

225000

... More
INDOOR UNITS CASSETTE TYPE WITH VRF

-

-

-

... More
4.0 TR Cassette for Passage Area

3

-

39900

... More
INDOOR UNITS HI WALL TYPE WITH VRF

-

-

-

... More
1.0 TR Hi Wall for Room

6

-

21900

... More
1.5 TR Hi Wall for Room

1

-

25800

... More
2.0 TR Hi Wall for Room

1

-

29300

... More
Supply, installation,testing and commissioning of Y- Joint

12

-

6000

... More
Supply, installation,testing and commissioning Manual Changeover Refrigerant Valve

4

-

18500

... More
Remort control for cassette AC unit

3

-

3500

... More
VRF Centralized control system

-

-

-

... More
Supply, Installation, testing & commissioning of Centralised Remote Controller (CRC) for the Entire Indoor and Outdoor Equipment Configuration for Above systems. Unit shall have provsion to ON/OFF entire VRF network, Temperature setpoint, Error detection on the screen (LCD screen with size not less than 10" x 5"), Emergency Stop, Schedule Program, Energy consumptio Kw/HP, % loading of VRF outdoor, Timer Extension, Schedule Program, Interlocking Control CRC shall have RS 485 port & shall be compatible with BMS. CRC shall Monitor & operate on a diagram by Layout view. Unit shall be compatible to interlocked or communicate with fire alaram signal. Note: CRC system shall not allow to trip entire VRV network if any of Indoor unit fails. CRC should always be inline with dedicated signals for both VRV units.

1

-

45000

... More
AHU Control Kit system

-

-

-

... More
SITC of Required AHU kit for connecting the Cooling coils with the VRF Outdoor unit complete with Electronic Expansion valve, Sensors, wired remote controller and PCB etc. as required.

3

-

59900

... More
Refrigerant pipe work

-

-

-

... More
Supply, fabrication, installation, testing of Interconnecting refrigerant pipe work with Armacell insulation (19 mm / 13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications,

-

-

-

... More
28.58 mm dia

50

-

1150

... More
25.40 mm dia

50

-

1050

... More
22.20 mm dia

50

-

950

... More
19.05 mm dia

75

-

850

... More
15.88 mm dia

75

-

750

... More
12.70 mm dia

75

-

650

... More
9.52 mm dia

75

-

550

... More
6.35 mm dia

75

-

450

... More
PVC drain piping with 9mm nitrile rubber insulation

-

-

-

30

-

180

50

-

150

50

-

120

... More
Electrical Work

-

-

-

... More
Providing & Fixing control cum transmission wiring of 2 core x 1.5 sq. mm copper in suitable conduit between Indoor and Outdoor unit.

300

-

120

... More
Providing & fixing wiring for indoor units from single phase power point provided by client. (3x2.5)

100

-

150

... More
Providing & fixing wiring for Outdoor units from three phase power point (16x4)

100

-

550

... More
Supplying & fixing of the 63A 4pole TPN With weather proof box.

2

-

6500

... More
Outdoor Stand

-

-

-

... More
Supply, Fabrication & fixing of MS iron works with painting complete as per approval & instruction.

3

-

6500

... More
Ducting detail ( Surgical , main OT & Minor OT)

-

-

-

... More
Supply,installation,testing and commissioning of Aluminium ducting with turning vanes, Aluminium supporting arrangement as per IS 655 and the detailed specification laid.

-

-

-

100

-

2150

100

-

1950

200

-

1850

... More
Duct Insulation & Accoustic

-

-

-

... More
Supply,installation,testing and commissioning of duct thermal insulation.

-

-

-

... More
19 mm thick Nitrile Rubber for indoor supply air ducting

200

-

1050

... More
Supply, installation, testing and commissioning of duct accoustic insulation with 15 mm thick

200

-

910

... More
Filter

-

-

-

... More
HEPA FILTER OT module made out of 16g aluminium sheets factory fabricated and fitted complete with minipleat filter of 99.97 % efficiency down to 0.3 micrron & 16g aluminium powder coated perforated Grille, OT module to be made out of 16 G aluminium in construction. Filters shall be considered as Minipleat ones with velocity ranging from 85 to 120 FPM with a minimum pressure drop not exceeding 25 mm wc, The module to be provided with aluminium low leakage volume control dampers at the inlet of the module, central opening for OT light pendents also to be considered. necessary GA drawings / technical specs to be approved before procurement. These modules to be suitable for ceiling suspension and necessary hooks / fitting arrangements to be provided to install these units along with Minipleat filters pressure testing, filter integrity testing ports.

-

-

-

... More
Size : 6ft. X 4ft.

2

-

33500

... More
OT Return air Risers (Floor mounted type) made out 20g Al Sheets and bottom filter, collar damer and perforated grill fixing arrangment, complete with pre filter of 20 micron, suitable filter removal arrangement, suitable for 450 to 650 cfm and each Riser height of 2.6 Mtr. The filter shall be flange type with outer dimension of 600 x 600 mm complete with 18g aluminium capsule perforated grills and grill fixing arrangement. Riser to be insulated with 13 mm thick nitrile rubber with suitable adhesive. necessary GA drawings / technical specs to be approved before procurement.

8

-

23500

... More
Damper, Diifuser & Grill

-

-

-

... More
Duct installation, flange type Strip heater boxes complete with strip heaters , power and control cabling, air stat, gyeserstat, humidistat (step type) suitble for re heating capacity ranging from 6 kW.

2

-

32500

... More
Defumigation arrangement for all OT ahus with interconnecting ducting, SISW Fan + Motor + Drive Package assembly, Dampers. SISW fan to size for 1800 CFM @ 25 mm static pressure, complete with DOL starter panel complete with BMS compatibiliy.

2

-

27500

... More
Supply, installation, testing and commissioing of OT pressure relief dampers (air pressure control valve) made out of SS 304, 18g suitable to maintain specified positive pressure in Ots and relief pressre when exceeded. (minimum size of 250 mm x 250 mm )

2

-

17500

... More
Extruded aluminium powder coated diffuser with aluminium collar dampers - Supply (Neck size-450x450)

6

-

9800

... More
Extruded aluminium powder coated diffuser without collar dampers - Return (Neck size-450x450)

6

-

9800

... More
Extruded aluminium powder coated Supply air grills with aluminium collar dampers - AC areas

3

-

7500

... More
Extruded aluminium powder coated Return air grills without collar dampers - AC areas

3

-

7500

... More
Extruded aluminium Fresh air / Exhaust air louver with bird screen

4

-

5500

... More
Aluminium 18g perforated Grills of 575 x 575 mm size (overall with 65% capsule perforation) for RA risers

6

-

11500

... More
Supply, installation, testing and commissioning of fire damper of suitable gauge as per specifications, standards and approved drawing (for supply air duct) to be integrated with the fire safety system and to switch off the AHU. Fusible Link type. Price of Fusible link to be included in the quoted price. ( Fire Dampers will be installed at each ahu supply and return air path).

6

-

9900

... More
Supply, installation, testing and commissioning of underdeck insulation with 50 mm thick PUF slabs fixed inner surface of concrete roof with addhesive approved by the manufacturer. (Underdeck insulation for exposed AC areas only)

100

-

950

... More
Canvas Connection

-

-

-

... More
Providing and fixing Fire retardant non porous double layer flexible connection between each Indoor unit and duct.

3

-

4550

... More
CIVIL WORKS

-

-

-

... More
Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from MS Sheet and galvanized with Zinc coating of 120gms/sqm ( both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide x 1.6 mm mm thick with flanges of 27mm and 37 mm at 1200 mm centre to centre one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6mm dia bolts, other flange of cleat fixed to angle hangers of 25 x 10 x 0.50 mm of requird size and other end of angle hanger fixed with intermediate GI channel 45 x 15 x 0.9 mm running at the spacing of 1200 mm centre to centre to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm at 450 mm centre to centre, shall be fixed in direction perpendicular to GI intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long GI wir at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall /partition with th help of rawl plugs at 450 mm entre with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making opening for lights fitting grill difussers cutout made with frame of perimter channel suitably fixed all complete as per drawing, specification and direction of the Engineers in charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum plain board conforming to IS :2095 (Part-I): 2011 (Board with BIS certification marks)

15

-

1117.6

... More
15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 ( 1 Cement : 4 sine sand)

20

-

307.9

... More
Demolishing R.B work manually / by mechanical means including stacking of steel bar and disposal of unserviceable materials within 50 meters lead as per direction of Engineer in charge

20

-

2267.15



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.