National Security Guard Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 35,196Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NSG_814625_1Bid Award Id
ViewTender No
11/CS/2024-25/NSGTender Authority
National Security Guard ViewPurchaser Address
-Website
http://https://www.nsg.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
3-5 ton Cassettee Air Conditioner
10
10560
1056
Servicing and Testing of 4.0 Ton Ductable Type Air conditioning unit including lubricating all movable parts, i.e. all types of motors, washing the cooling coil, condenser coil with water and a non-acidic cleaning agent, cleaning of the filter, checking for all types of faults, cleaning of outer body, testing fan alignment of the blower motor, removing water leakage if any, etc. complete as required.
2
3662
1831
B. Gas charging and topup
Supplying and charging of R-22/ R-410A/R-32 suitable refrigerant Gas (as per manufacturer's recommendations) in the following type and capacity Air Conditioner including detecting and removing the leakage, brazing, pressure testing after removing the leakage, flashing, vacuumizing, testing etc. complete as reqd.
-
-
-
1.5/2.0 ton Split/Window/Cassettee Air Conditioner
100
263100
2631
3.0 to 5.0 Ton Split/Cassettee /ductable Air conditioner.
5
18330
3666
Supplying and toping up of suitable AC refrigerant gas (R- 22/R-32/R410A) in split type 1.5 ton /2 ton AC unit etc. complete as required.
70
66010
943
C. Compressor replacement and repair Replacement of the existing reciprocating/rotary compressor of the following capacities split air conditioner units, including cutting and joining the suction and discharge copper pipes,p brazing, and testing, including dismantling the old worn-out compressor, etc. The dismantled compressor will be kept by the contractor and the net rate will be quoted, reducing its value. (one year manufacturer's Warranty on new Compressor). (Makes-Carrier Totaline/ Emerson/ Hitachi/ LG/ Tecumseh/ kirloskar/ Voltas )
-
-
-
1.5 ton Split AC
10
119410
11941
2 ton Split / Cassettee Air Conditioner
10
141519
14151.99
3-5 ton Split / Cassettee Air Conditioner
1
25508
25508
D. Repair of Accessories Outdoor/ Indoor unit Providing and replacement of following spare part suitable for Split type AC unit of 1.5/2 TR capacity i/c dismantling the existing defective spare part, testing and commissioning of the same including credit for old scrap material which will be retained by the contractor. etc. complete as reqd. (Six months warranty will be provided on the repaced spares by the contractor)
-
-
-
Outdoor Fan Blade for 1.5 Ton /2 Ton capacity Split AC.
10
17350
1735
Condenser fan motor for 1.5 Ton /2 Ton capacity Split AC.
5
15475
3095
Indoor Blower Motor for 1.5 Ton /2 Ton capacity Split AC.
5
16920
3384
Split AC Indoor Swing Motor for 1.5 Ton /2 Ton capacity Split AC.
5
5490
1098
Indoor Blower Wheel for 1.5 Ton /2 Ton capacity Split AC.
5
14930
2986
Metal Jaali Cover for Outdoor Units' Fan. for 1.5 Ton /2 Ton capacity Split AC.
10
8320
832
Running capacitor 35 to 55 MFD for 1.5 Ton /2 Ton capacity Split AC.
30
18360
612
Capacitor 3 MFD to 6 MFD for 1.5 Ton /2 Ton capacity Split AC.
30
15060
502
AC Remote with batteries for 1.5 Ton /2 Ton capacity Split AC.
5
3525
705
Thermostatic expansion valve for 1.5 Ton /2 Ton capacity Split AC.
5
5535
1107
Temperature sensor for 1.5 Ton /2 Ton capacity Split AC.
5
3635
727
Copper condenser coil for 1.5 Ton Split AC
5
30425
6085
Copper condenser coil for 2.0 Ton Split AC
5
43445
8689
Condensate removal pumps in 1.5/2 TR Split/Cassettee AC
1
6818
6818
Providing and fixing of the OEM MADE/RECOMMENDED PCBs of existing fixed speed Split/Cassette ACs SIMILAR TO ONES ALREADY INSTALLED IN THE UNIT, including dismantling existing falulty PCB and including credit for old scrap PCB which will be retained by the contractor etc. as required with 6 months warranty.
-
-
-
1.5 ton Non invertor Split AC/ cassette AC
10
55830
5583
2 ton Non invertor Split / Cassettee Air Conditioner
4
28016
7004
Providing and fixing 1/2 inches dia nylon braided flexible drain pipe for split/cassettee air conditioners etc. as required.
100
11600
116
Providing extra copper tubing / piping for refrigerant, insulation and 3 core x 2.5 Sq. copper condutor cable for 1.5/2TR Split AC as per manufacturers specification , clamps, etc. complete as reqd. (two copper pipes one suction and one discharge line with wire and foam insulation tubing will be measured as one unit) .
30
39180
1306
Supplying and wrapping white/beige waterproof tape around existing refrigerant ac pipes, etc. complete as required. [Measurement shall be done linearly along length of pipe]
300
6000
20
Supplying and fixing of following sizes of PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible-multi stranded) industrial cable, 1100 Volt, conforming to IS 694 through conduits/walls etc. as required. (Make-Havells/Polycab/ RR Kable / Finolex )
-
-
-
4 c x 2.5 sqmm
100
20900
209
6 c x 2.5 sqmm
50
18200
364
Providing and fixing CPVC pipe 20 mm dia with all accessories e.g. elbows, unions, sockets, reducers, reducing tees, nipples etc., including fixing the pipe with clamps at 1.00 m spacing on wall / floor etc. as required. (Make-Ashirwad /Astral /Finolex/ Supreme/ Prayag )
50
8600
172
Supplying and fixing of heavy guage outdoor wall mounted bracket suitable for 1.5/ 2 ton split Air conditioner outdoor unit etc. complete as required.
5
5380
1076
Supplying and fixing of heavy guage outdoor floor mounted bracket suitable for 1.5/ 2 ton split Air conditioner outdoor unit etc. complete as required.
5
5380
1076
Supplying and fixing of nitrile rubber insulation for refrigerant copper pipe i/c sealing the joint with tape, removing damage insulation, including credit for old scrap material which will be retained by the contractor. etc. complete as required..
301
12943
43
Dismantling of existing of 1.5 ton /2.0 ton split air conditioner with indoor unit, out door unit and copper piping etc. complete as reqd.
10
8730
873
Installation testing and commissioning of 1.5 ton /2.0 ton split air conditioner with indoor unit, out door unit and copper piping etc. as required.
10
16590
1659
Supply, Installation, testing and commissioning of wall mounted type voltage stabilizer suitable for 1.5 Ton Split Air conditioner with High / Low voltage cut off, thermal overload relay and Time Delay Relay, WORKING VOLTAGE RANGE : 150-285 (minimum) Volts including connection etc. as required. (V-Guard/Totaline / Logicstat / Microtek/Luminous / Bluebird with minimum 3 year warranty.)
10
52540
5254
Supply, Installation, testing and commissioning of wall mounted type voltage stabilizer suitable for 2 Ton Split Air conditioner with High / Low voltage cut off, thermal overload relay and Time Delay Relay, WORKING VOLTAGE RANGE : 150-285 (minimum) Volts including connection etc. as required. (V-Guard/Totaline / Logicstat / Microtek/Luminous / Bluebird with minimum 3 year warranty.)
4
23404
5851
Supplying and fixing of following sizes of PVC trucking (Casing and Capping) along with accessories like elbow, coupling, tee in surface. etc. as required. (Make-Precision /Legrand / AKG / MK-Honeywell / Pressfit)
-
-
-
20 mm x 12 mm
50
2700
54
50 mm x 50mm
10
2530
253
100 mm x 100 mm
30
45840
1528
Checking and testing the following capacities air conditioning unit for any mechanical and/or electrical faults, troubleshooting i/c cleaning the filters and removing water leakage (if any) etc. complete as required.
-
-
-
1.5 ton / 2 ton Split/Cassettee/Window AC
30
18240
608
Providing Services of AC Mechanic (Grade-II) on as and when needed basis.Payment will be done for number of man-days served duly verified by department and 1 Man-day = 8 hrs of work shift as per labour laws
23
32453
1411
Supplying, installation, testing and commissioning of 1.5 Ton, Inverter type, 5 Star BEE rating, Air conditioner complete with all standard accessories ( Indoor Unit, Outdoor Unit, Inter-connecting kit with copper pipe wrapped with insulation, Drain pipe and connecting cable, remote control, user manual with warranty certificate as per OEM specifications). i) Refregirant pipe, insulation & Inter-connecting cabe length upto 3 mtrs.
ii)Warranty : 1 Year on complete Unit, 5 Years on PCB card and min 09 years on Compressor .
iii) Rated ISEER : minimum 5.0.
2
155158
77579
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.[For Fabricating frame ODUs of split AC -.Design/Shape will be decided by Engineer-in-charge]
100
13370
133.7
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
-
-
-
Two or more coats on new work
20
4525
226.25
Credit for old existing split AC etc complete as required
-
-
-
i) 1.5 TR
3
-15000
-5000
ii) 2.0 Ton
3
-16500
-5500
Credit for old dismantled copper refregirant pipe
30
-4500
-150
Credit for old dismantled ODU stands
5
-150
-30
Credit for old dismantled AC Stablizers
15
-3000
-200
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements