Directorate Of Urban Local Bodies Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 53,40,000Document Cost
₹ 1,000Tender Fee
₹ 1,180
Summary
Rfp For Water Line Scada For The Entire Water Supply System By Providing A Central Monitoring And Control Station Located At Iccc Building At Faridabad Including Operation And Maintenance For 5 Years In Faridabad
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_HRY_148070_1Bid Award Id
ViewTender No
FSCL/2020/2729Tender Authority
Directorate Of Urban Local Bodies ViewPurchaser Address
-Website
http://https://ulbharyana.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
200mm
24
-
-
... More
250mm
25
-
-
... More
300mm
36
-
-
... More
350mm
19
-
-
... More
400mm
4
-
-
... More
450mm
2
-
-
... More
500mm
1
-
-
... More
600mm
9
-
-
... More
900mm
3
-
-
... More
Providing & Replacement of Old Flow convertors with new Flow Converters, Modbus output suitable for existing flow heads and Integration with SCADA system (Bidders shall visit the site for exploring the compatability of the flow converters with existing flow transmitters)
125
-
-
... More
DS Cable Supply & Erection for old Flow meters from Flow Converter to Flow Tube
1250
-
-
... More
Ultrasonic/Radar level transmitter Designing, Supplying, Installing, commissioning & testing of Ultrasonic /Radar type level transmitter with following technical parameters and Interfacing with PLC/RTU panel including mounting arrangement. Output-4-20 mA Power supply 24V DC ext. Range- 0 to 5m/0-10m as per site depth Accuracy - +/- 0.25% of Full Scale or better Enclosure- IP 67 at field locations and integration with PLC/RTU at Ranney well, MBS, IBS & SBS Locations of suitable depth. (detail specifications at Section – 7.2)
113
-
-
... More
Pressure Transmitter Designing, Supplying, Installing, commissioning & testing of pressure transmitter with following technical parameters and Interfacing with PLC/RTU panel including mounting arrangement. Output 4-20 mA Power supply - 24V DC Accuracy - +/- 0.1 % of full scale or better Enclosure- IP 67 at Individual Pumps & Common Header Points (detail specifications at Section – 7.2)
510
-
-
... More
Glyscerine Filled Pressure gauge Bourdon's type as IS 3624:1987 Mounting - direct bottom, stainless steel body, toughened glass window Pressure gauge 150 mm dia (black & red marking) at Individual Pumps & Common Header Points (detail specifications at Section – 7.2)
113
-
-
... More
Designing, Supplying, Installing, commissioning & testing of Energy Meter interfacing to PLC/RTU Panel with Modbus communication port , as per IEC 62053 and in the prescribed format including mounting arrangement complete in all respect. (detail specifications at Section – 7.2)
113
-
-
... More
Providing, installation, testing and commissioning of UPS (minimum size 2 KVA) with at least 4 Hrs backup at all the stations so as to control entire entire instrumentation, PLC/RTU etc. (detail specifications at Section – 7.2)
113
-
-
... More
Automation & Control Requirements
-
-
-
... More
Supply, Installation, Commissioining of Remote Terminal Units(RTU)/PLC sufficient AIOs and DIOs, with HMI 7" Screen with 65000 Colours, as might be necessary including , Panel Box IP54 rated, fitting and accessories including capability to communicate Central control room, MPS, Cables, JBs, Trays & Conduits etc. at Ranney wells so as to perform functionalities as per scope of work at Renny Well Locations Tentative AIODIO: DI-19,DO-10,AI-7, Modbus-1, Ethernet port -1 (detail specifications at Section – 7.2)
16
-
-
... More
Supply , Installation & Commissioining of Remote Terminal Units(RTU)/PLC with sufficient AIOs and DIOs, with HMI 7" Screen with 65000 Colours as might be necessary including , Panel Box IP54 rated, fitting and accessories including capability to communicate Central control room, MPS, Cables, JBs, Trays & Conduits etc, so as to perform functionalities as per scope of work for Controlling 12 Nos Motors Pumps set with required Instrumentation at MBS/IBS/SBS; Tentaive AIODIO: DI-58,DO-29,AI-17, Modbus-1, Ethernet port -1 (detail specifications at Section – 7.2)
3
-
-
... More
Supply, Installation & Commissioining of Remote Terminal Units(RTU)/PLC with sufficient AIOs and DIOs, with HMI 7" Screen with 65000 Colours as might be necessary including , Panel Box IP54 rated, fitting and accessories including capability to communicate Central control room, MPS, Cables, JBs, Trays & Conduits etc, so as to perform functionalities as per scope of work for Controlling 10 Nos Motors Pumps set with required Instrumentation at MBS/IBS/SBS; Tentative AIODIO : DI-48,DO-24,AI-14, Modbus-1, Ethernet port -1 (detail specifications at Section – 7.2)
7
-
-
... More
Supply, Installation & Commissioining of Remote Terminal Units(RTU)/PLC with sufficient AIOs and DIOs, with HMI 7" Screen with 65000 Colours as might be necessary including , Panel Box IP54 rated, fitting and accessories including capability to communicate Central control room, MPS, Cables, JBs, Trays & Conduits etc, so as to perform functionalities as per scope of work for Controlling 8 Nos Motors Pumps set with required Instrumentation; Tentative AIODIO: DI-38,DO-19,AI-12, Modbus-1, Ethernet port -1 (detail specifications at Section – 7.2)
18
-
-
... More
Supply, Installation & Commissioining of Remote Terminal Units(RTU)/PLC with sufficient AIOs and DIOs, with HMI 7" Screen with 65000 Colours as might be necessary including , Panel Box IP54 rated, fitting and accessories including capability to communicate Central control room, MPS, Cables, JBs, Trays & Conduits etc, so as to perform functionalities as per scope of work for Controlling 6 Nos Motors Pumps set with required Instrumentation at MBS/IBS/SBS, Tentative AIODIO : DI-29,DO-14,AI-10, Modbus-1, Ethernet port -1 (detail specifications at Section – 7.2)
24
-
-
... More
Supply, Installation & Commissioining of Remote Terminal Units(RTU)/PLC with sufficient AIOs and DIOs, with HMI 7" Screen with 65000 Colours as might be necessary including , Panel Box IP54 rated, fitting and accessories including capability to communicate Central control room, MPS, Cables, JBs, Trays & Conduits etc, so as to perform functionalities as per scope of work for Controlling 4 Nos Motors Pumps set with required Instrumentation at MBS/IBS/SBS, Tentative AIODIO: DI-19,DO-10,AI-7, Modbus-1, Ethernet port -1 (detail specifications at Section – 7.2)
25
-
-
... More
Supply, Installation & Commissioining of Remote Terminal Units(RTU)/PLC with sufficient AIOs and DIOs, with HMI 7" Screen with 65000 Colours as might be necessary including , Panel Box IP54 rated, fitting and accessories including capability to communicate Central control room, MPS, Cables, JBs, Trays & Conduits etc, so as to perform functionalities as per scope of work for Controlling 2 Nos Motors Pumps set with required Instrumentation at MBS/IBS/SBS Tentative AIODIO : DI-10,DO-5,AI-5, Modbus-1, Ethernet port -1 (detail specifications at Section – 7.2)
20
-
-
... More
Providing, Erecting commissioning & giving test and trial of the fully automatic gas Chlorination system confirmation to all applicable NEC and Compressed Gas Associations recommendations as per Specification (detail specifications at Section – 7.2)
7
-
-
... More
Integration of all Remote locations. i.e. Renney wells, Tube wells, MBS, IBS & SBS at Central control room with ICCC (ICCC Hardware & Software Requirement)
-
-
-
... More
Workstation with dual TFT Monitors (OWS)
2
-
-
... More
Developmental console with one TFT (EWS)
1
-
-
... More
Water SCADA software for entire water supply scheme as per scope of work requirement
1
-
-
... More
A4 size All in one Colour Laser printer
1
-
-
... More
GSM/GPRS Connectivity At all PLC Locations
113
-
-
... More
Motors, Pumps & MCC requirement(Replcement of exisitng Pumps & Motors by Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal
Centrifugal Split Casting pumps with motor , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. And Motor Horizontal FootMounted IE3 type 4 Pole TEFC, S1 duty, IP-55, 415 Volts Squirrel cage Enclosure confirming to protection IP55 suitable for operation on 415 +/- 10%V, 3 Phase 50 HZ +/- 5% AC supply with ambient 50C class F insulation with temperature rise limited to class B Induction Motors confirming to IS-325 & IS 12615 - 2011 with latestamendments. of the following rating complete with all respect. (detail specifications at Section – 7.2) The motor rating shall be worked out by considering following factors:- 1.Pump efficiency =75 %
2. Cupling efficiency =98 %
3.Motor Efficiency IE 3
(Attach the motor rating calculation sheet as per Annexure-11)
)
-
-
-
... More
Discharge 20 to 30 LPS and head 20 to 30 M
8
-
-
... More
Discharge 20 to 30 LPS and head 31 to 40 M
6
-
-
... More
Discharge 31 t0 40 LPS and head 20 to 30 M
4
-
-
... More
Discharge 41 t0 50 LPS and head 20 to 30 M
6
-
-
... More
Discharge 51 to 60 LPS and head 41 to 50 M
4
-
-
... More
Discharge 61to 70 LPS and head 51to 60 M
6
-
-
... More
Discharge 71 to 80 LPS and head 41 to 50 M
1
-
-
... More
Discharge 71 to 80 LPS and head 51 to 60 M
5
-
-
... More
Discharge 181 to 200 LPS and head 41 to 50 M
1
-
-
... More
Discharge 181 to 200 LPS and head 51 to 60 M
5
-
-
... More
Discharge 201 to 220 LPS and head 41 to 50 M
5
-
-
... More
Discharge 201 to 220 LPS and head 51 to 60 M
3
-
-
... More
Discharge 301 to 325 LPS and head 51 to 60 M
3
-
-
... More
Repalcement of Exisiting VT pumps by Providing, erecting, testing and commissioning Vertical Turbine pumps with motor, CI casing and SS 410 casing ring, SS 316 impeller, SS 410 shaft sleeve, coupling with guard, common base plate of each of 295 m3/hr Capacity 30m Head with Electromechanical works and all allied accessories including LT panels at Renny Well Location (detail specifications at Section – 7.2)
10
-
-
... More
Modification in Exisiting MCCs for PLC Compatibality
113
-
-
... More
Replacement of Exisiting old MCC Panels with new Panels (Soft Starter detail specification section 7.2) for new Pumps- Motor sets with PLC compatability
67
-
-
... More
Repalcement of old Contractors, MCBs & Isolater in Existing MCC
34
-
-
... More
Electrical & Allied Works (Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors,
suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. (detail specifications at Section – 7.2)
)
-
-
-
... More
100 mm width X 50 mm depth X 1.6 mm thickness meter
3060
-
-
... More
150 mm width X 50 mm depth X 1.6 mm thickness meter
512
-
-
... More
225 mm width X 50 mm depth X 1.6 mm thickness meter
300
-
-
... More
300 mm width X 50 mm depth X 1.6 mm thickness meter
150
-
-
... More
Providing and laying Stranded/ Flexible Annealed Bare copper conductor ,XLPE/PVC insulated suitably laid up together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wire overall PVC sheathed (ST-1) overall screened Pair armoured instrumentation Cables
generally confirming to PAS 5308- Part-2-2009.( detail specifications at Section – 7.2)
-
-
-
... More
1 pair
5100
-
-
... More
2 pair
1280
-
-
... More
4 pair
500
-
-
... More
Supplying and erecting XLPE / PVC, Aluminium conductor Three core, XLPE / PVC insulated & armoured Power cables for Motors & Electrical Power supply of Instruments, insulated, armoured cable 1100 V grade with ISI mark Three core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall / on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.
-
-
-
... More
3 Core 25 sq mm
220
-
-
... More
3 Core 35 sq mm
280
-
-
... More
3 Core 50 sq mm
140
-
-
... More
3 Core 70 sq mm
140
-
-
... More
3 Core 95 sq mm
100
-
-
... More
3 Core 120 sq mm
80
-
-
... More
3 Core 150 sq mm
200
-
-
... More
3 Core 185 sq mm
40
-
-
... More
3 Core 240 sq mm
80
-
-
... More
3 Core 300 sq mm
80
-
-
... More
3 Core 400 sq mm
120
-
-
... More
Providing Maintenance free chemical earthing Suitable for PLC & Instruments
113
-
-
... More
Comprehensive work for Internal improvement (dressing of exisiting cabling, switch board & wiring at Renney Wells, MBS, IBS & SBS’s) (Bidders has to visit the sites for assessment of the scope as payment will be made after entire satisfaction of engineer-in-charge site-wise as the works relates to propoer routing of cabeling, re-fixing of new panels etc.)
113
-
-
... More
Operation & Maintenance ( For 5 Years Inclusive of Defect Liability Period of 1 Year) for Instrumentation, Automation & Control & ICCC Requirements
-
-
-
... More
DLP Period For 1st Year including 1st year O&M
1
-
-
... More
O&M For 2nd Year
1
-
-
... More
O&M For 3rd Year
1
-
-
... More
O&M For 4th Year
1
-
-
... More
O&M For 5th Year
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements