Maharaja Agrasen Medical College Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 2,90,000Document Cost
₹ 15,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_HRY_228985_2Bid Award Id
ViewTender No
MAMC/Engg./347 Dated 06-07-2022Tender Authority
Maharaja Agrasen Medical College ViewPurchaser Address
-Website
http://https://www.mamc.edu.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Centering and shuttering including strutting, propping etc. and removal of form for: (HSR-21, 6.30)
Suspended floors, roofs, landings, balconies.(HSR-21, 6.30.3)
40
-
-
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level.
Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR-21, 6.34)
Thermo-Mechanically Treated bars of grade Fe-500D or more. (HSR-21, 6.34.6)
400
-
-
Brick work with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in :(HSR-21, 7.22)
Cement mortar 1:4 (1 cement: 4 coarse sand) (HSR-21, 7.22.1)
20
-
-
15 mm cement plaster on the rough side of single or half brick wall of mix : (HSR-21, 11.6)
1 :4 (1 cement: 4 fine sand) (HSR-21,11.6.1)
125
-
-
Providing and fixing hard drawn steel wire fabric 75 mm X 25 mm rectangular mesh with 3.25 mm dia wire fixed on steel windows of standard rolled sections with 3 mm thick flat iron cover moulding of 12.5 mm width fixed with machine screws welded complete in all respect. (HSR-21,13.18)
125
-
-
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.(HSR-21,13.29)
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (HSR-21,13.29.2)
1000
-
-
Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1 :3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1 :4 (1 cement : 4 coarse sand) : (HSR-21, 22.81)
100 mm dia (HSR-21,22.81.1)
200
-
-
75 mm dia
125
-
-
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. (HSR-21, 22.83)
60
-
-
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1 :4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1: 2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1 :3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : (HSR-21, 22.175)
With common burnt clay non-modular bricks of class designation
7.5 (HSR-21,175.1)
40
-
-
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(HSR-21, 22.181)
40000
-
-
Making holes by cutting cores of appropriate dia in RCC floors and roofs of thickness up to 6" (six inches) for passing drain pipe and repairing the hole after insertion of drain pipe etc. including finishing-complete so as to make it leak proof. (HSR-21,30.82)
Drain pipe of 150mm internal dia (HSR-21,30.82.1)
80
-
-
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 2850 lpm at 88 m Head (N.S.)
2
-
-
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2850 lpm at 88 m Head (N.S.)
1
-
-
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 88 m Head (N.S.)
2
-
-
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head (N.S)
4
-
-
CONTROL PANELS Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : Incomings
800A, 50kA 4 Pole MCCB, Ics=100% Icu Rating. Digital Voltmeter 0-500V with selector switch. Ammeter (0-800 A) with selector swtich & CTs etc.
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps
Set of Copper Bus Bar 1000Amps Outgoings
(Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)
Main Fire Pump
250 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation,
selector switch for local/remote, auto/manual/OFF operation. - 2 sets
Jockey Pump
125 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets
DIESEL ENGINE CONTROL
Control for diesel engine comprising -
Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode
Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter
All standard relays and accessories for automatic operation of diesel engine
System Controller
Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification
consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification. (N.S)
1
-
-
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150 mm. Dia (N.S.)
25
-
-
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (N.S.)
25 mm dia
4387
-
-
32 mm dia
927
-
-
40 mm dia
503
-
-
50 mm dia
360
-
-
65 mm dia
346
-
-
80 mm dia
439
-
-
100 mm dia
349
-
-
150 mm dia
363
-
-
200 mm dia (wall thickness 6.3 mm)
10
-
-
250 mm dia (wall thickness 6.3 mm)
10
-
-
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel (N.S.)
25
-
-
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel (N.S.)
25
-
-
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : (N.S)
50mm dia
8
-
-
65mm dia
2
-
-
80 mm dia
20
-
-
100 mm dia
9
-
-
150 mm dia
11
-
-
200 mm dia
5
-
-
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : (N.S)
100 mm dia
4
-
-
150 mm dia
4
-
-
200 mm dia
4
-
-
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. (N.S)
33
-
-
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : (N.S)
65 mm dia
5
-
-
80 mm dia
5
-
-
100 mm dia
9
-
-
150 mm dia
8
-
-
200 mm dia
4
-
-
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
200mm dia (N.S.)
3
-
-
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal (N.S.)
90
-
-
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
40 M length (N.S.)
33
-
-
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304) (N.S)
45
-
-
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe (N.S.)
4
-
-
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. (N.S)
4
-
-
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories: (N.S)
Pendant type
3150
-
-
Upright
650
-
-
Horizontal side wall sprinkler
65
-
-
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (N.S)
9
-
-
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.
150 mm dia (N.S.)
10
-
-
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150 mm dia (N.S.)
3
-
-
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
1000 mm (N.S.)
400
-
-
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required. (N.S)
400
-
-
Providing, installing, testing & commisioning of fire brigade draw out connection (fire department connection) with suction pipe MS class 'C' 100 mm dia. & 100 mm dia. foot valve & steel chain including wall mounted box M.S. construction with glass door to house the above mentioned componenets. (N.S)
1
-
-
Providing and fixing Air vessel 450 mm dia 8mm thick MS sheet 1800mm in height with air release valve on top & flanged connection to riser, drain arrangement with 25mm dia gunmetal wheel valves and the legs shall be provided MS plate size 75x75x5 mm at the bottom and grouted in CC foundation. with required accessories, pressure gauge & painting with synthetic enamel paint of approved shade as required. (N.S)
2
-
-
Providing and fixing dial type pressure gauge with isolation cock and pipe at hydrant station & sprinkler line. Dia 100 mm calibration 0-15 Kg. (N.S.)
12
-
-
Providing ,fixing and commissioning of 1.6mm thick MS door frame 900x2100 door capable of accommodating fire hose reel, landing valve, hose pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (as per Existing shaft). (N.S.)
33
-
-
Providing ,fixing and commissioning of 1.6mm thick M.S. fire hose cabinet (750x600x250mm) made out of 16 gauge M.S. sheet capable of accommodating landing valve, hose pipes, fittings & accessories. The box shall have a front glass door with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) - for external and roof hydrant. (N.S.)
23
-
-
S/F Fire man axe as reqd. (N.S.)
33
-
-
Providing and fixing portable fire extinguisher, dry powder type (gas cartridge) with cylinder initially fully charged with dry powder (ABC type) of 4 Kg. Complete with standard discharge valve with tube, CI bracket for wall mounting etc. conforming to IS: 115683. (N.S)
33
-
-
Providing and fixing portable fire extinguisher carbon dioxide type with cylinder initially fully charged with CO2 gas of 4.5 Kg. Capacity, complete with discharge valve, dishcarge tube, horn, CI bracket for wall mounting etc. conforming to IS: 15683. (N.S)
33
-
-
Providing and fixing of submersible non-clog, open impeller sump pump with vortex impeller 400/440 volts, 50 cycles AC supply of the following specifications:(3 Phase motor) with auto sequential change over with both pumps shut at low level, one pump working at mid level and both pump working and an alarm hooter at high level all pre set ,including 10 m pipe length and valve & fitting as required complete in all respects.
Discharge: 180 lpm
Head : 10 metre
HP : 2HP or As required.
Casing : Aluminium alloy /C.I
Impeller & Shaft: S.S. 410
Solid Handling Capacity: 40 mm
Length of water proof cable with each pump : 10 meter
Level controller Quantity : each set (1W+1SB) (N.S.)
1
-
-
Providing and fixing C.I. double acting air valves of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if reqd. will be paid separately) (N.S)