Lala Lajpat Rai University Of Veterinary And Animal Sciences Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 17,100Document Cost
₹ 1,000Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_HRY_251098_1Bid Award Id
ViewTender No
UWD/2022/D/1878Tender Authority
Lala Lajpat Rai University Of Veterinary And Animal Sciences ViewPurchaser Address
-Website
http://https://haryana.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
HSR 30.27.1
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: 30.27 .1 One or more coats on old work
2466.51
-
47
... More
HSR 11.71.1
Wall painting on a cement plaster surface with acrylic emulsion paint of approved brand and manufacture to give an even shade : 11. 7.1 Two or more coats on new work
464.86
-
61
... More
HSR 11.58
Providing and applying two coats white cement based putty of approved sqm 26 10 36 brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete
2466.51
-
36
... More
HSR 22.104.1
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 22.104.1 15 mm nominal bore
(a) 15 mm nominal bore
5
-
387
... More
HSR 22.106.1
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
5
-
512
... More
HSR 21.84
Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1 :5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1 :2:4 benching 12mm thick cement plaster 1 :2 with a floating coat of 1 mm thick of neat cement R.C.C. 1 :2:4 slab 100 mm thick/cement concrete topping, 50mm thick: with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per 1.5.1. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 21.84.1 Size 450 mm X450 mm inside (with 455 mm x 455 mm cover each 3905 3905 and frame light duty single seal weighing 20 kg with C.C. topping
2
-
3905
... More
HSR 21.84.2
Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover each 5573 5573 and frame single seal pattern I weighing 38 kg with C.C. topping
2
-
5573
... More
(C ) Size 600 mm X900 mm inside (with 455 mm x 455 mm cover each 6090 6090 and frame light duty single seal weighing 20 kg with R.C.C. slab)
2
-
6090
... More
HSR 23.8.11
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect HSR No. HSR 23.8.11.1 5 amp 1 way switch
140
-
46
... More
HSR 23.8.11.4
15 amp 1 way switch
43
-
92
... More
HSR 23.8.11.5
5 amp. Socket
31
-
92
... More
HSR 23.8.11.7
15 amp 6 pin socket
43
-
139
... More
HSR 23.8.11.10 Blinking Plate
40
-
20
... More
HSR 23.22
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. HSR 23.22.1.3 TRIPLE POLE MCCB 16 to 100 Amp, 25 KA
2
-
5190
... More
HSR 23.22.4
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to to the entire satisfaction of the Engineer-in-Charge of the work
23.22.4.6 TPN DB Horizontal type Double Door 6 way ( 8 incoming 3phase*6 outgoing)
4
-
3669
... More
HSR 23.22.5
Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections: 23.22.5.1 6 amp to 32 amp Single pole
72
-
152
... More
HSR 23.5.1
Wiring only in 1.5 sqmm PVC insulated copper conductor cable for LIGHT/FAN/Call bell point in existing conduit pipe and MS boxes including cost of Bakelite cover for MS box, switch, wall socket, ceiling rose/connector etc. 23.5.1.2 Group B
109
-
327
... More
HSR 23.5.2
Wiring only in existing conduit and MS box for Twin control light point with 2 nos , 2-ways, 5 amp. switch in 1.5 sqmm FRLS PVC insulated copper conductor cable . 23.5.2.2 Group B
2
-
922
... More
HSR 23.5.4
Wiring in existing conduit and MS box for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch etc complete as required 23.5.4.2 Group B
31
-
450
... More
HSR 23.5.5
Wiring in existing conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch etc complete as required
23.5.5.2
Group B
43
-
774
... More
HSR 23.5.6
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required.
23.5.6.2
run of Size 2.50 Sqmm(1.1.80mm)
1600
-
87
... More
HSR 23.5.6.3
1 run of Size 4 Sqmm(1/2.24mm)
500
-
122
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements