Lala Lajpat Rai University Of Veterinary And Animal Sciences Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 14,800Document Cost
₹ 1,000Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_HRY_251107_1Bid Award Id
ViewTender No
UWD/2022/D/1879Tender Authority
Lala Lajpat Rai University Of Veterinary And Animal Sciences ViewPurchaser Address
-Website
http://https://haryana.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Providing Aluminium Partitions and Mineral Fibre False Ceiling in VCC Department, LUVAS, HISAR
Providing Aluminium Partitions and Mineral Fibre False Ceiling in VCC Department, LUVAS, HISAR
BOQ Items
HSR 12.158 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade I Type II, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge HSR 12.1258.2 Pre-laminated particle board with decorative lamination on both sqm sides
41.22
-
883
HSR 12.160 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight up to 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
HSR 12.160.1 With stainless steel cover plate minimum 1.25 mm thickness
6
-
2282
HSR 12.164 Providing and fixing Brass 100mm mortice latch and lock with 6 levers each without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
3
-
359
HSR 12.167 Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge
HSR 12.167.1 Anodized (AC 15 ) aluminium
6
-
74
HSR 30.23 White washing with lime to give an even shade
HSR 30.23.1 Old work (two or more coats)
211.64
-
9
HSR 32.47 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance i!: 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L- shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main 'T'. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. HSR 32.47.2 With 20 mm thick bevelled tegular mineral fibre false ceiling tile (NRC 0.7)
75.01
-
1641
HSR 20.71.1 Supply,erection,testing of ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge. 48" (1200 mm)
6
-
2300
HSR 23.4.1 Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper HSR 23.4.1.3
Group c
24
-
795
HSR 23.4.4
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp
Modular type switch required GI Box ,modular face plate etc complete as required
HSR 23.4.4.3
Group C
10
-
1047
HSR 23.4.5 Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4
sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling ,
including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16
Amp Modular switch required GI Box , modular face plate etc complete as
required HSR 23.4.5.1
Group C
32
-
1447
HSR 23.5.6
Wiring main and sub mains in two single core for phase and neutral wire
and one single core for earth wire PVC insulated Copper conductor cable
1100 Volts grade in existing MS/PVC Conduit etc as required.
HSR 23.5.6.6
2 run of Size 1.50 Sqmm(1/1.40mm)
150
-
129
HSR 23.5.6.8 2 run of Size 4 Sqmm(1/2.24mm)
220
-
262
HSR 23.7.6
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. (TELEPHONE)
HSR 23.7.6.1
PVC pipe of 20mm dia
150
-
29
HSR 23.7.6.2
PVC pipe of 25mm dia
220
-
36
HSR 23.8.11
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. HSR 23.8.11.13
32A D.P. Main Switch With Key Ring Tag 2 Module
4
-
367
HSR 23.20. Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required
18
-
75
HSR 23.22
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. HSR 23.22.1
Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work.
HSR 23.22.1.9
4 pole MCCB 6 amp to 100 amp
1
-
6865
HSR 23.22.1.11
4 pole MCCB 200 to 250 amp
1
-
12104
HSR 23.22.2
MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings
HSR 23.22.2.1 MCCB up to 125 A FP
1
-
2032
HSR 23.22.2.2 MCCB up to 250 A FP
1
-
4515
HSR 23.22.4
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to to the entire satisfaction of the Engineer-in-Charge of the work
HSR 23.22.4.11
vertical TPN DB Double Door 8 way ( 8 incoming 3phase*8 outgoing)
1
-
9051
HSR 23.22.5
Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:
HSR 23.22.5.1
6 amp to 32 amp Single pole
24
-
162
HSR 23.22.5.6
40 amp to 63 amp. MCB's TRIPLE POLE
1
-
1162
HSR 23.22.6
Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. HSR 23.22.6.3
DP RCCB 30ma sensitivity , 63 A
1
-
2324
HSR 23.22.7
Supply and erection of blanking sheet in existing distribution board.
20
-
9
HSR 23.22.8
SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings
HSR 23.22.8.3
200 amp 415 volts
1
-
16751
HSR 23.23.3
Supply and erection of girder clamp for ceiling fan including painting (up to 15 cm section)
HSR 23.23.3.2
Girder clip complete for girder up to 300 mm deep
6
-
62
HSR 23.23.4
Providing and fixing fan hook made from 8 mm dia MS rod 75 cm long of required shape and size
6
-
81
HSR 23.24.2
Erection of Cubical type Electrical Panels/ Feeder Pillars including necessary mounting Frame made of suitable size I section of required size on existing foundation/platform etc as required HSR 23.24.2.1 Panels/Feeder Pillars having incomers up to Four pole 200 A , Base Mounting frame made of ISMC 100*50*5 mm
1
-
2800
EL-1
Supply and instalation, testing and commissioning of 36 watt 2*2, plano panel recess specification I/P voltage 160-240 v AC , tempreture -5700k, 50000Hr. Life with 100 lumens per watt
18
-
2350