Karnal Smart City Limited Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Karnal Smart City Limited - KSCL Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date4 Mar 2022
Closing Date28 Mar 2022
Tender AmountRefer Documents 
Notes
Download

Costs

  • EMD

    ₹ 28,00,000
  • Document Cost

    ₹ 20,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
UPS DB's

6

-

5500

... More
Supply, installation, Testing and Commissioning of 3phase and Neutral 415V, 4 wire Free Standing, Floor mounted MV panel made out of 2mm thick CRCA sheet after seven tank process and Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A per Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit with standing capacity of minimum 50KA and consist of the switch gear as mentioned below. The panel shall be got fabricated from manufacturers with CPRI Test certificate only. The PCC shall have at least two spare cubicles of the maximum outgoing MCCB rating. The Panels shall be mounted on ISMC-75 including supply and fixing of the same. Every ACB shall be provided with ON/OFF/Trip Indication lamps of LED type. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely. All MCCBs shall be provided with microprocessor based releases & with Neutral link. The fault level indicated in the Schedule are the minimum ratings All Switchgear shall have Rotary Handles. All CTs shall be Cast Resin Type (CRT). NOTE.: ATLEAST 2NOS DUMMY CUBICLES SHALL BE PROVIDED SUITABLE FOR THE HIGHEST RATED OUTGOING MCCBs.All the Panels shall have provision for extending on both the sides.All Incomers Switchgears shall have 4NO + 4NC Auxilliary Contacts inbuilt.The panel shall be extendable type on both the sides.Note: Wiring from all energy meters RS485 ports & Auxiliary contacts of Switch gear shall be brought to a common terminal block with in panel for BMS Metering Monitoring /on/off/Trip status feedback.MAIN PCC PANELEB Incomer 1: 1250A 50KA,EDO FP ACB with Microprocessor based overload, Earth fault & Earth leakage releases with resin cast CBCT – 1setDG SYNC Panel Incomer 2: 1000A 50KA,EDO FP ACB with Microprocessor based overload, Earth fault & Earth leakage releases with resin cast CBCT – 1setBuscoupler : 1250A 50KA,EDO FP ACB with Microprocessor based releases – 1setBus bars : 1250A TPN Aluminium Bus bars with 100% neutral – 1SetOutgoings: 400A 50KA TPN MCCBs – 5nos250A 50KA TPN MCCBs- 2nos160A 50KA TPN MCCBs- 3nos125A 50KA TPN MCCBs- 5nos63A TPN MCCBs- 5nos160A,25KA TPN MCCB and 50KVAR 415V Delta connected MPP Capacitor Banks -1no63A 50KA FP MCCB with TVSS- 1NoNOTE: THE PANEL SHALL BE EXTENDABLE TYPE. Metering :LED Phase indication lamps with MCB and control with toggle switches- 3sets0-500V Digital Voltmeter with selector switch – 2sets 0-1250A Digital Ammeter with resin cast CTs of ratio 1250/5A, Class 1 Accuracy and 15VA burden and selector switch – 1set0-1000A Digital Ammeter with resin cast CTs of ratio 1000/5A, Class 1 Accuracy and 15VA burden and selector switch – 1set1250-600/5A, Class 1 Accuracy and 15VA CT in 'R' Phase for APFCR – 1setKW Transducers with required CT with 0-10V Output –2setsCT operated Digital Load Manger with RS 485 connectivity with suitable ratio & burden resin cast CT's– 2sets CT operated Digital Energy Meter with RS 485 connectivity with suitable ratio & burden resin cast CT's and Digital Ammeter with selecter switch – 1set CT operated Dual Source Electronic Digital Energy Meter with RS 485connectivity with suitable ratio & burden resin cast CT's and Digital Ammeter with selecter switch – 36sets Each Capacitor bank shall be provided with Auto/Manual selector switch, On/Off Push buttons for manual operation, On/Off Indication lamps, suitable range analogue Ammeter with resin cast CTs of 10VA burden and selector switch. The Capacitors shall be provided in the Panel itself with proper ventilation arrangementsNote: All Incoming & Outgoing Breakers shall have minimum 2NO+2NC Potential free contacts for BMS On/off/Control status indications.Note : PLC based Electrical Interlocking with auto change over to be provided for both the Incomers and Bus coupler.Note : Provision for DG AMF sensing to be made.

1

-

2100000

... More
AUTOMATIC PF IMPROVEMENT PANEL (25KVAR)Incoming : 250A 50KA TPN MCCB with Neutral link – 1set

1

-

200000

... More
Control Panels (On each floors) : Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required,Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels. Incomer :315A FP MCCB - 1NOS Outgoing : 63A TPN MCB - 5NOS; 40A TPN MCB - 12NOS & 32A DP MCB's - 3nos Indication lamps (RYB) with control MCB - 03 Sets Danger notice plate Make : As listed in UHBVNL

4

-

125000

... More
STP (B1) : Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required,Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels. Incomer :100A FP MCCB - 1NOS Outgoing : 63A MPCB with S/D starters with water level controller,L/R selector switch, remote control for 10HP – 2Nos Indication lamps (RYB) with control MCB - 03 Sets Danger notice plate Make : As listed in UHBVNL

1

-

75000

... More
STP & Lifts (B1) : Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required, Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels. Incomer :125A FP MCCB - 1Nos Outgoing : 32A MPCB with S/D starters with water level controller,L/R selector switch – 6Nos Indication lamps (RYB) with control MCB - 03 Sets Danger notice plate Make : As listed in UHBVNL

1

-

100000

... More
Supply, laying and commissioning of following size 1.1KV grade XLPE insulated armored aluminum/Copper conductor under ground cable, in built up cable trench/already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 50mtr. interval and also at the turnings. The cable shall conform to IS 7098.3.5 core 300Sq.mm

200

-

910

... More
Supply, laying and commissioning of following size 1.1KV grade XLPE insulated armored aluminum/Copper conductor under ground cable, in built up cable trench/already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 50mtr. interval and also at the turnings. The cable shall conform to IS 7098.3.5 core 185Sq.mm

100

-

590

... More
Supply, laying and commissioning of following size 1.1KV grade XLPE insulated armored aluminum/Copper conductor under ground cable, in built up cable trench/already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 50mtr. interval and also at the turnings. The cable shall conform to IS 7098.3.5 core 150Sq.mm

100

-

490

... More
Supply, laying and commissioning of following size 1.1KV grade XLPE insulated armored aluminum/Copper conductor under ground cable, in built up cable trench/already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 50mtr. interval and also at the turnings. The cable shall conform to IS 7098.3.5 core 70Sq.mm

500

-

330

... More
Supply, laying and commissioning of following size 1.1KV grade XLPE insulated armored aluminum/Copper conductor under ground cable, in built up cable trench/already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 50mtr. interval and also at the turnings. The cable shall conform to IS 7098.3.5 core 50Sq.mm

300

-

295

... More
Supply, laying and commissioning of following size 1.1KV grade XLPE insulated armored aluminum/Copper conductor under ground cable, in built up cable trench/already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 50mtr. interval and also at the turnings. The cable shall conform to IS 7098.3.5 core 35Sq.mm

250

-

265

... More
Supply, laying and commissioning of following size 1.1KV grade XLPE insulated armored aluminum/Copper conductor under ground cable, in built up cable trench/already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 50mtr. interval and also at the turnings. The cable shall conform to IS 7098.4 core 16Sq.mm Al.Ar.Cable

1000

-

240

... More
Supply, laying and commissioning of following size 1.1KV grade XLPE insulated armored aluminum/Copper conductor under ground cable, in built up cable trench/already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 50mtr. interval and also at the turnings. The cable shall conform to IS 7098.4 core 10Sq.mm Al.Ar.Cable

700

-

220

... More
Supply, laying and commissioning of following size 1.1KV grade XLPE insulated armored aluminum/Copper conductor under ground cable, in built up cable trench/already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 50mtr. interval and also at the turnings. The cable shall conform to IS 7098.4 core 6Sq.mm Al.Ar.Cable

300

-

185

... More
Supply, laying and commissioning of following size 1.1KV grade XLPE insulated armored aluminum/Copper conductor under ground cable, in built up cable trench/already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 50mtr. interval and also at the turnings. The cable shall conform to IS 7098.4 core 6Sq.mm copper Ar.cable

800

-

220

... More
Supply, laying and commissioning of following size 1.1KV grade XLPE insulated armored aluminum/Copper conductor under ground cable, in built up cable trench/already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 50mtr. interval and also at the turnings. The cable shall conform to IS 7098.3core 2.5sq.mm Copper flex cable

1200

-

140

... More
Supply, laying and commissioning of following size 1.1KV grade XLPE insulated armored aluminum/Copper conductor under ground cable, in built up cable trench/already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 50mtr. interval and also at the turnings. The cable shall conform to IS 7098.3core 4sq.mm Copper(for 5HP Motors)

200

-

165

... More
Supply, laying and commissioning of following size 1.1KV grade XLPE insulated armored aluminum/Copper conductor under ground cable, in built up cable trench/already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 50mtr. interval and also at the turnings. The cable shall conform to IS 7098.3core 6sq.mm Copper (For 7.5HP Motors)

200

-

185

... More
Supply, laying and commissioning of following size 1.1KV grade XLPE insulated armored aluminum/Copper conductor under ground cable, in built up cable trench/already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 50mtr. interval and also at the turnings. The cable shall conform to IS 7098.3core 1.5sq.mm Copper

300

-

115

... More
SITC of 20W LED Batten having Extruded aluminium housing fitted with Engg. Plastic end caps. With Opal diffuser.LED should be populated on FR4 PCB in which LED’s should be mounted & connection should be in series parallel.LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level)=110lumens/watt, Minimum system Lumens 4400 lm ±10%. Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500K ±500K, CRI=80, PF=0.9,THD10%, and Operating Temperature Range-10 deg C to +50deg C, IP20. Built in Surge Protection of 4KV and an operating Voltage Range of 140 to 300V AC,50Hz.The driver should be constant current driver.The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance.

155

-

1085

... More
SITC of LED recessed 18W Downlighter with a nominal system lumen output of 1800 lumens ±10% and a minimum system efficacy of 100 lm/W. The luminaire should have a color temperature of 5700K and CRI80. The luminaire shall meet IP20 rating with THD10% and PF 0.95. Built-in Surge protection of 2 kV, Maintenance of lumen output 50000 hrs.The luminaire housing should made of pressure die cast aluminium with a high efficiency diffuser.Bajaj Cat. Ref BZSLOS nxt 18L LED WH SD

56

-

1385

... More
SITC of recessed mounted LED 600x600mm fitting made of CRCA) sheet steel housing comprising of LED’s connected in series parallel,Opal diffuser fixed in separate white powder coated ,Opal diffuser frame is held in with housing by screws for easy maintenance. Fixture should have minimum efficacy at System level (Not Chip Level) =100lumens/watt, ,Minimum system Lumens 3600 lm ±10%Life of fixture 50000hrs@L70 Lumen maintenance, CCT up to 5700K±300K, CRI minimum 80, PF ≥0.95, THD 10% and an operating Voltage Range of 140 to 277V AC. Minimum Internal Surge Protection 2.5 kV. The fixture should comply with the other parameters as per IS10322 and specifications. Bajaj Cat. Ref BZSSLL 36W LED WH i

94

-

2800

... More
Supply of 40W LED industrial Weatherproof Batten having Extruded aluminium housing fitted with end caps. Luminaire should be Completely prewired with accessories up to terminal block and fixture should have minimum efficacy at System level (Not Chip Level)=120lumens/watt, Minimum system Lumens 4800 lm ±10%. Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500K ±500K, CRI=80, PF=0.9,THD10%, and Operating Temperature Range-10 deg C to +50deg C, IP65,IK07. Built in Surge Protection of 4KV and an operating Voltage Range of 140 to 300V AC,50Hz.The driver should be constant current driver. The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance. Bajaj Cat. Ref.BI PC 40W Pro LED SD or Equivalent.

10

-

2800

... More
SITC of 12" (300mm) Cabin fan.

8

-

1500

... More
SITC of 300mm swepp Light duty exhaust fan with metal blades etc complete

18

-

2000

... More
SITC of energy efficient fan, 1200 mm sweep, aluminium body, consuming 28 W, BEE 5 star rated, ceiling fan with Brush Less Direct Current(BLDC)motor, class of insulation: B, 3 no's blades, 30 cm long down rod, 2 no's canopies, suitable for 230V, 50 HZ, single phase AC supply, earthing etc., including all standard accessories etc., complete.

20

-

2800

... More
SITC of 25A Metal clad sockets for 2TR Air conditioner

10

-

2200

... More
Supply and installtion of 90W Streetlight to be mounted on 6mtr poles having Epoxy powder coated pressure die‐cast aluminium housing, Weatherproof gaskets should be provided for LEDs and control gear compartments. Luminaire should be suitable for Side entry mounting for max. 38mm OD pipe bracket. The LED driver access should be from top for easy maintenance. LEDs should be provided with non‐yellowing modular secondary lens optics .LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level)=120lumens/watt, Minimum system Lumens 18000 lm ±10%. Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 5665K ±355K, CRI=70, PF=0.9,THD10%, and Operating Temperature Range-5 deg C to +45deg C, IP66. Built in Surge Protection of 4KV & external surge protection of 10kVand an operating Voltage Range of 140 to 270V AC,50Hz.Luminaire Weight should not exceed 1.5kg.The driver used is specially designed to have built‐in surge voltage, open/short circuit protections. The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance. Make : Bajaj/Philips/Surya/VAK/Crompton

20

-

7500

... More
Suitable bracket to mount 9W flood light on 8mtr pole 1000mm Single arm bracket

20

-

1200

... More
Supply of following size XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part - I) 4C x 10sqmm Al Ar cable

400

-

122

... More
Street Lighting control Panel : Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required,Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels. Incomer :40A TPN MCB - 1NOS Outgoing : 25 TPN MCB's - 3nos Indication lamps (RYB) with control MCB - 03 Sets with Timer and Contactor Danger notice plate Make : As listed in UHBVNL

1

-

35000

... More
Supply Installation Testing and Commissioning and Interfacing of BMS software with Lighting, Fire Fighting, HVAC equiments, CCTV, STP, Pumps etc including providing of suitable monitors and training to O&M

1

-

4000000

... More
All Fire Extinguisher shall be HCFC, CFC and Halons free. The Fire Extinguisher Manufacturer/Supplier shall provide declaration, Technical Data Sheet/cutsheet of All type of Fire extinguisher to be installed. Providing and fixing ABC stored pressure dry chemical powder (mono ammonium phosphate) Fire Extinguisher IS : 15683 latest revision manufacturer and of CRCA sheet in welded construction, finish with High quality epoxy polyster powder coated complete with brass forged ball valve, gun metal cap and nozzle, including initial filled and wall suspension bracket (suitable for fighting in class 'A', B & 'C' that is wood, textile, flammable liquid, electric and gases). Capacity 6 Kg (IS : 15683 : 2006)

30

-

5491

... More
Supply, installation, testing and commissioning of Ceiling hung / Floor Mounted type Tube Axial flow fan having suitable mm WC Static Pressure of following capacity with powder coated G.S.S/M.S. casing and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller shall directly driven by TEFC induction motor (efficiency 1) having 'F' class insulation suitable for 3 Phase, 50 Hz, 415±10% Volt, AC supply, 1400 RPM , necessary fire retardant canvas conection etc. complete as required and as per specifications. Fan should be AMCA certified, Fan should be statically & dynamically balanced upto G 2.5 as per ISO 1940 & AMCA 204/3 standard. Tube Axial Flow Fans of 900 impeller dia with 18000 CFM capacity

8

-

65000

... More
Supply, installation, testing and commissioning of Ceiling hung / Floor Mounted type Tube Axial flow fan having suitable mm WC Static Pressure of following capacity with powder coated G.S.S/M.S. casing and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller shall directly driven by TEFC induction motor (efficiency 1) having 'F' class insulation suitable for 3 Phase, 50 Hz, 415±10% Volt, AC supply, 1400 RPM , necessary fire retardant canvas conection etc. complete as required and as per specifications. Fan should be AMCA certified, Fan should be statically & dynamically balanced upto G 2.5 as per ISO 1940 & AMCA 204/3 standard. Tube Axial Flow Fans of 1000 impeller dia with 19000 CFM capacity

4

-

60000

... More
Supply, installation, testing and commissioning of Ceiling hung / Floor Mounted type Tube Axial flow fan having suitable mm WC Static Pressure of following capacity with powder coated G.S.S/M.S. casing and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller shall directly driven by TEFC induction motor (efficiency 1) having 'F' class insulation suitable for 3 Phase, 50 Hz, 415±10% Volt, AC supply, 1400 RPM , necessary fire retardant canvas conection etc. complete as required and as per specifications. Fan should be AMCA certified, Fan should be statically & dynamically balanced upto G 2.5 as per ISO 1940 & AMCA 204/3 standard. Jet fans of approx 350 dia with 2600 CFM capacity

16

-

35000

... More
Supply, Installation, testing & commissioning of complete Security Systems(CCTV) including all accessories 2 MP Fixed Dome type camera

6500

-

12

... More
Supply, Installation, testing & commissioning of complete Security Systems(CCTV) including all accessories 2 MP Bullet Type camera

9500

-

12

... More
Supply, Installation, testing & commissioning of complete Security Systems(CCTV) including all accessories CC TV cable CAT 6

20

-

750

... More
Supply, Installation, testing & commissioning of complete Security Systems(CCTV) including all accessories G.I. Conduit for CAT 6 cable

70

-

750

... More
Supply, Installation, testing & commissioning of complete Security Systems(CCTV) including all accessories LCD monitor - 34 inch

55000

-

1

... More
Supply, Installation, testing & commissioning of complete Security Systems(CCTV) including all accessories DVR

65000

-

1

... More
Supply Installation Testing and Commissioning VRV based air conditionining system as per follwing: a. For Type 5-10sqmtr shops : 1x1TR split AC's b. For Type 10-12 sqmtr Shops : 1x1.5TR Split A.C’s c. For Type 12-14 Shops : 2x1TR Split A.C’s d. Along with related 18HP Outdoor units, Copper pipe and other accessories

3

-

1500000

... More
Supply,Installation,Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications asamended, consisting of Mono/PolyCrystalline silicon solarcells, netmetering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286/IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants / systems must be warranted for their output peakwatt capacity, which should not be less than 90% attheend of 10years and 80% at the end of 25 years. b)PowerConditioningUnit(PCU) of 350-800V DC Input voltage range and 400VAC, threephase, 4wire, 50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3 and suitable for ambient temperature from 0 to 50 degreeC. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories. d Fixing of Array junctionbox & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection. f)Connections & Interconnections by supplying &fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc.as required.

52.37

-

61060

... More
Providing & Installing of Gearless Passenger Elevator,Capacity 884 Kg / 13 person,speed 1.00 meter /sec,control high performance simplex full collective control system Drive: Ac VVVF Drive for more power saving,comfort & safe ride.Stops/opening :03 Stops/03 Opening,travel 18 meters approx,Gearless Machine Shall Be Placed within the shaft(MRL),S.S Hairline Finish Cabin, PVC Flooring on heavy duty M.S. Platform, Decorative False Ceiling WithCFL/LED Lighting, Blower/Rotor motor Fan.Clear Opening 800mm wide x 2000mm Height,Car door Center Opening Automatic Door ( SS Hairline Finish) Power Supply Three Ø 415 V AC, 50 Hz +/- 5% Single Ø 230 V AC, 50 Hz +/- 5%,These Components are generally confirmed as per Indian Standard Specification for Elevators orEscalators,SPECIAL FEATURES 1. Direction arrow with digital position indicators in car and at all landing ,2. Very attractive push buttons with illuminated call registration light in car and all landings ,3. Car emergency light, emergency alarm and emergency stop operation,4. Intercom communication system from car to ground floor & machine room.,5. Voice announcing system for car,6. Full length infrared door curtain safety for auto doors,7. Automatic rescue device in case of power failure or emergency landing (ARD),8. Fireman switch safety device as per elevator & escalator act.,9. Overload warning device (OLWD). All complete fitting as directed by engineer in charge.Make required Orbis,Jhonson,Kone,otis

1

-

1947750

... More
Providing & Installing of Gearless Passenger Elevator,Capacity 680kg/10 person,speed 1.00 meter /sec,control high performance simplex full collective control system Drive: Ac VVVF Drive for more power saving,comfort & safe ride.Stops/opening :03 Stops/03 Opening,travel 18 meters approx,Gearless Machine Shall Be Placed within the shaft(MRL),S.S Hairline Finish Cabin, PVC Flooring on heavy duty M.S. Platform, Decorative False Ceiling WithCFL/LED Lighting, Blower/Rotor motor Fan.Clear Opening 800mm wide x 2000mm Height,Car door Center Opening Automatic Door ( SS Hairline Finish) Power Supply Three Ø 415 V AC, 50 Hz +/- 5% Single Ø 230 V AC, 50 Hz +/- 5%,These Components are generally confirmed as per Indian Standard Specification for Elevators orEscalators,SPECIAL FEATURES 1. Direction arrow with digital position indicators in car and at all landing ,2. Very attractive push buttons with illuminated call registration light in car and all landings ,3. Car emergency light, emergency alarm and emergency stop operation,4. Intercom communication system from car to ground floor & machine room.,5. Voice announcing system for car,6. Full length infrared door curtain safety for auto doors,7. Automatic rescue device in case of power failure or emergency landing (ARD),8. Fireman switch safety device as per elevator & escalator act.,9. Overload warning device (OLWD). All complete fitting as directed by engineer in charge.Make required Orbis,Jhonson,Kone,Otis

1

-

1749000

... More
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. DIESEL ENGINE CONTROL Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification

2

-

245730

... More
Pumps: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 1620 lpm at 56 m Head

1

-

282515

... More
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2850 lpm at 56 m Head

1

-

510945

... More
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head

1

-

81196

... More
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads 450 lpm at 35 m Head

1

-

85291

... More
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. DIESEL ENGINE CONTROL Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification

1

-

245730

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizescomplete as required.200 mm. dia (wall thickness = 6.3 mm)

75

-

3169

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizescomplete as required.150 mm. Dia

250

-

2376

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia

1000

-

471

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :65 mm dia

30

-

1004

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia

30

-

1122

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia

350

-

40

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless Steel cap and chain as required:Single headed Gunmetal

10

-

7494

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :65 mm dia

8

-

4149

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :80 mm dia

20

-

4842

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 mm dia

8

-

6454

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :150 mm dia

6

-

8699

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :200 mm dia

5

-

14958

... More
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :40mm dia

8

-

5618

... More
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :50mm dia

8

-

7094

... More
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :150mm dia

5

-

22550

... More
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :200mm dia

5

-

39133

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required

10

-

1291

... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.80 mm dia

5

-

4573

... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia

5

-

10659

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun Metal

15

-

5188

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m

15

-

8413

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.

2

-

18009

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Pendent Sprinkler

350

-

484

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.

40

-

1508

... More
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 100mm dia

10

-

7362

... More
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 150mm dia

10

-

8869

... More
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm dia

1

-

47898

... More
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 700mm

35

-

1341

... More
Supplying, installation, testing & commissioning of deluge valve (to be used for sprinkler system) UL listed with wet pilot basic trim assembly for DVA with test and alarm, drip and drain valve with water motor gong complete as required. 150mm dia

1

-

114963

... More
Fire Hydrant single outlet gunmetal NB inlet brass spindle 63mm female instantanous/outlet with PVC blank cap and GI chain as per IS:5290 (ISI Marked) Single head gunmetal hydrant valve Short stainless steel branch pipe 63mm male intantanous inlet male threaded outlet fitted with 15mm bore nosle as per IS:903 (ISI Marked)

7

-

4685

... More
FBC CI Body having two nos. gunmetal 63mm male instantanous inlet coupling confirming to IS:903 fitted with non return valve flange outlet of 100mm dia complete with 25mm size gunmetal drain valve, two nos. rubber blanck caps and chainFour way gunmetal FBC connection

1

-

9462

... More
Sythetic fibre circular woven jackated rubber lined fire hose delivery having 38Kg. Per Cm. Sq. burst pressure, 28Kg. Per Cm. proof pressure, 14Kg. Per Cm. working pressure as per IS:636 (ISI Marked) Type A in 15 Meters length, 63mm dia duly copper via bounded two coupling pair of male female parts any duly intantanous type, 63mm size as per IS:903 (ISI Marked) RRL Hose with male female gunmetal coupling

20

-

3861

... More
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.

180

-

1141

... More
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.

85

-

462

... More
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.

6

-

184

... More
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.

18

-

545

... More
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.4 Zone

10

-

8468

... More
Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 10 Zone panel for fire alarm system 250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required - 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required -1 set. Amplifier change over switch for inter changing amplifier -1 No. Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch- 1 No. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos.12 volt, 60 AH each sealed maintenance free batteries -1 set.

1

-

69084

... More
INTELLIGENT FIRE ALARM SYSTEM Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Ten Loop Panel

1

-

454896

... More
PUBLIC ADDRESS SYSTEM Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.

1

-

126399

... More
PUBLIC ADDRESS SYSTEM Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.

72

-

1780

... More
PUBLIC ADDRESS SYSTEM Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required.

6

-

145780

... More
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.

600

-

328

... More
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Speaker cable Two pair, 2-core, 1.5 sqmm

600

-

85

... More
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.

650

-

50



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.