Irrigation And Water Resources Department Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Irrigation And Water Resources Department - GoH Tender

Works
Machinery and Tools
Electrical and Electronics
Electrical Works
Eprocure
Opening Date15 Oct 2024
Closing Date4 Nov 2024
Tender Amount₹ 5,29,22,000 
Notes
Download

Costs

  • EMD

    ₹ 10,58,440
  • Document Cost

    ₹ 20,000
  • Tender Fee

    ₹ 1,180

Summary

Providing And Installation Of New 04 No. Pumps Of 20 Cs, 01 No. Pump Of 15 Cs, And 03 No. Pumps Of 10 Cs. Capacity Alongwith Allied Electro-mechanical Equipmets I.e Motor, Starter, Ltdb Panel, Pvc Alluminium Cable, Transformer, Acb Panel, Ismb .....

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply Installation & commissioning of 09/10 Cs. existing V.T. axial flow pump having lift 17.02’ RPM-1450, including MS Delivery pipe with all flange, y-body, bend, Syphon breaker valve with any left over items duly painted inner & outer site as per site requirement & specification approved by technical committee (Annexure-A) at pump houses. (PH SBD-4=2)

2

-

-

... More
Supply, Erection and commissioning of Solid shaft motor of capacity 120 HP, 980 RPM, 3 phase, 440/415 Volt suitable for 20 Cs. V.T. axial flow pump vertical flange mounted as per site and specification approved by technical committee at pump houses. (PH SBD-1=2, SBD-2=1, SBD-3=1)

4

-

-

... More
Supply, Erection and commissioning of Solid shaft motor of capacity 60 HP, 1450 RPM, 3 phase, 440/415 Volt suitable for 10 Cs. V.T. axial flow pump vertical flange mounted as per site and specification approved by technical committee at pump houses. (PH SBD-2=1, SBD-4=2)

3

-

-

... More
Supply, Erection and commissioning of Solid shaft motor of capacity 100 HP, 1450 RPM, 3 phase, 440/415 Volt suitable for 15 Cs. V.T. axial flow pump vertical flange mounted as per site and specification approved by technical committee at pump houses. (PH SBD-5=1)

1

-

-

... More
Supply, Erection and Commissioning of fully automatic ATS starter suitable for 120 HP motor with suitable contactor for main transformer/ start,alongwith capacitor banks of suitable size, interliking bush bar of suitable size complete in all respect with degree of protection IP 54 complete with small item like air cooled ATS, thimble, nut bolt, lugs etc. with the stand of MS angle (50x50x6 mm) of 1 feet height from floor level with allied accessories as per site and approved make and specificaion by irrigation and WR department Haryana. (PH SBD-1=2, SBD-2=1, SBD-3=1)

4

-

-

... More
Supply, Erection and Commissioning of fully automatic ATS starter suitable for 100 HP motor with suitable contactor for main transformer/ start,alongwith capacitor banks of suitable size, interliking bush bar of suitable size complete in all respect with dagree of protection IP 54 complete with small item like air cooled ATS, thimble, nut bolt, lugs etc. with the stand of MS angle (50x50x6 mm) of 1 feet height from floor level with allied accessories as per site and approved make and specificaion by irrigation and WR department Haryana. (PH SBD-5=1)

1

-

-

... More
Supply, Erection and Commissioning of fully automatic ATS starter suitable for 60 HP motor with suitable contactor for main transformer/ start,alongwith capacitor banks of suitable size interliking bush bar of suitable size complete in all respect with dagree of protection IP 54 complete with small item like air cooled ATS, thimble, nut bolt, lugs etc. with the stand of MS angle (50x50x6 mm) of 1 feet height from floor level with allied accessories as per site and approved make and specificaion by irrigation and WR department Haryana. (PH SBD-2=1, SBD-4=2)

3

-

-

... More
Supply erection and commissioning of LTDB 800 amp. capacity with 01 incomer of MCCB 800 amp., with 03 no. outgoing each of having 300 amp. MCB for lighting loads indicator, relays, meters, push buttons, bus bar of 100 HP with additional arrangement ON/OFF switch in front of motor for every starter with a stand of MS Channel (01 feet above from floor) as per site condition and as per specification approved by technical committee. (Annexure- C, D, F) (PH SBD-1 & SBD-2)

2

-

-

... More
Supply erection and commissioning of LTDB 400 amp. capacity with 01 incomer of MCCB 400 amp., with 03 no. outgoing each of having 125 amp. MCB for lighting loads indicator, relays, meters, push buttons, bus bar of 100 HP with additional arrangement ON/OFF switch in front of motor for every starter with a stand of MS Channel (01 feet above from floor) as per site condition and as per specification approved by technical committee. (Annexure- C, D, F) (PH SBD-3, SBD-4, SBD-5)

3

-

-

... More
Providing & installation of Transformer capacity 400 KVA 11/.4 KV step down 3-phase 50 Hz outdoor (including ACSR conductor 50 sqmm (Rabbit), GSL 85WG GI Nuts and bolts of sizes, eye screw bolt wt. 0.483 kg, earthing rod wt. 6.175 kg GI pipe 40 mm dia 6 meter, long earthing set B class, GI strip 25x6mm 9 meter, for earthing wt. 10.80 kg, lightening arrestor 9 KV, HT XLPE cable 3 C* 50 sqmm with TR, termitation kit O/D 3 C* 50 sqmm, wooden gutkha GI channel 100x50x6 mm 2200 mm for holding fuse board, LT fuse board with bus bar and aluminium patti, fencing with gate and stone gravesl in switch yards area, plinth structure including PCC pole 11 meter long with half clamp weight 1.47 kg HVPN Drg. no. 2349, 11 KV polymeric pin with insulator, 11 kV polymeric disc insulator with fitting (T&C type), stay set 8 feet long complete with X-plate 460 m of angle 65x65x6 mm elbow & rod wt. 13.80 kg, stay wire 7/8 SWG, GI channel 75x40x6 mm 2200 mm for fuse unit wt. 15.708 kg, GI channel 100x50x6 mm 2200 mm for H-pole wt. 21.032 kg, 11 KV GO switch complete with handle, pipe and supporting channel, single core HT 630 sqmm cable with proper thimbling and any other left over items if any as per site requirement and specification approved by DHBVN department) all type of third party inspection charges i.e. Pre-Dispatch, Final inspection, M&P, CEI inspection, departmental inspection etc during any state inclusive of rate. .(PH SBD-1 to SBD-5= 5 No.)

5

-

-

... More
Supply, laying and installation of LT 1100 Volts Cable PVC XLPE armoured Aluminium Conductor of sizes as mentioned as per relevant IS specification & approved make as per annexure-c in technical specification of Haryana Irrigation Deptt. various sizes as below: (a) Single Core 630 Sq. MM

2000

-

-

... More
(b) 3.5 Core 185 Sq. MM

1200

-

-

... More
Providing and commissioning of LT ACB Panel of Capacity 800 Amps including all accessories as ACB 800 Amps and 01 No. 63 amp. MCB as outgoing for accessiores supply, indicators,alongwith capacitor banks of suitable size, relays, meters, push buttons,bus bars etc complete suitable for contorl of power supply in switch room with the stand of MS angle (50x50x6 mm) of 1 feet height from floor level with allied accessories as per requirement at site as per specification approved by Tech committee including power capacitor bank of pump houses as per site requirement (Annexure-C). (PH SBD-1, SBD-2)

2

-

-

... More
Providing and commissioning of LT ACB Panel of Capacity 400 Amps including all accessories as ACB 400 Amps and 01 No. 63 amp. MCB as outgoing for accessiores supply,alongwith capacitor banks of suitable size, indicators, relays, meters, push buttons,bus bars etc complete suitable for contorl of power supply in switch room with the stand of MS angle (50x50x6 mm) of 1 feet height from floor level with allied accessories as per requirement at site as per specification approved by Tech committee including power capacitor bank of pump houses as per site requirement (Annexure-C). (PH SBD-3, SBD-4, SBD-5)

3

-

-

... More
Fabrication including welding work of safety grating jaal, trash rack, safety grills, outer jaal etc. for fixing in bay gap of pumps inside pump house in different dimensions as per site requirement and as directed with material fabricated with MS Channel 150x75x5mm/100x50x5mm, MS flat 75x8 mm/32x5mm MS Angle 40x40x5mm, MS Chaquered sheet thickness 8 mm etc. Make:- Tata/ Jindal/ Sail/Vaizag. (PH SBD-1 to SBD-5= 2000 Kg. each.)

10000

-

-

... More
Structural steel work riveted bolted or welded in built up sections trusses and framed work including cutting hosting and fixing in position and applying a prime coat of approved steel primer. (Providing & fixing by making required size /length at site in pair of MS cross Girder (ISMB) in 2 run of length of size 300 mmx140mm for foundation of 20 CS VT Axial Flow pump including supply, fixing & welding One end of ISMB shall be grouted into wall by making arrangement of PCC block of suitable size as per weight of pump 20 Cs capacity and other end shall be welded with fixing of L. bracket and nut/bolts/washers etc into existing ISMB member. (MAKE: TATA/JINDAL/SAIL/VAIZAG) Providing and new installation of Girder for 20Cs capacity VT Axial Flow pump as per specification approved by technical committee.

400

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.