Haryana Vidyut Prasaran Nigam Limited Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Haryana Vidyut Prasaran Nigam Limited - HVPNL Tender

Works
Civil And Construction
Electrical Generators And Transformers
Building Construction
Electrical and Electronics
Eprocure
Opening Date11 Jun 2024
Closing Date29 Jul 2024
Tender AmountRefer Documents 
Notes
Download

Costs

  • EMD

    ₹ 32,96,589
  • Document Cost

    ₹ 11,800
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
132 kV Isolator with E/Switch

2

-

-

... More
132 kV Isolator without E/Switch

10

-

-

... More
132 kV Surge Arrestor

12

-

-

... More
132 kV Post Insulator

10

-

-

... More
132 kV CTs For Line & Bus Coupler (600-300-150/1-1-1 A)

9

-

-

... More
132 kV T/F CT (250-150-100/0.577-1-1-1 A)

6

-

-

... More
132 kV PT for line

6

-

-

... More
132kV C&R Panels a) Transformer Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS

2

-

-

... More
b) Line Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS

2

-

-

... More
c) Bus Coupler Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS

1

-

-

... More
Time synchronization equipment

1

-

-

... More
132 kV NCT (250-150-100/1)

2

-

-

... More
33 kV VCB for O/G line bays & C/bank(630A)

5

-

-

... More
33 kV T/F Incomer VCB (1250A)

2

-

-

... More
33 kV LA’s for lines, I/C T/F & C/Bank

21

-

-

... More
33kV C&R Panels a) 33kV Transformer I/C Protection and Circuit Breaker Panel with one no. Energy Meter (Without Auto Reclose). with SAS

2

-

-

... More
b) 33kV Line Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS

3

-

-

... More
c) 33 kV Capacitor Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS

2

-

-

... More
33kV Isolator for line, Station T/F & capacitor bank (630A)

6

-

-

... More
33kV Isolator for I/C 40/50 MVA, 20/25 MVA 132/33KV Transformer & for 33kV bus sectionalizer (1250A)

3

-

-

... More
33 kV L&E Switch for Line & capacitor bank (630A)

5

-

-

... More
33 kV PT for bus

6

-

-

... More
33 kV CT for Line and Capacitor Bank (600-300/5-1A)

15

-

-

... More
33 kV I/C T/F CT (1000-600-400/0.577-5-5-1A)

6

-

-

... More
33 kV NCT (1000-600-400/5A)

2

-

-

... More
1x10.872 MVAR 33kV Capacitor Bank along with Structure & allied equipment (i.e Series Reactor, NCT) as per specification

1

-

-

... More
1X 5.43 MVAR 33kV Capacitor Bank along with Str. & allied equipment (i.e Series Reactor, NCT) as per specification

1

-

-

... More
220 V 200 AH SAN Tubular Battery

1

-

-

... More
220 V 200 AH SMPS Based Battery charger

1

-

-

... More
220 V 200 AH D.C.D.B

1

-

-

... More
415 V LT AC Distribution Board 300 A

1

-

-

... More
33/0.4 kV Station T/F 200 KVA

1

-

-

... More
250TB Marshalling kiosk including mounting structure

5

-

-

... More
a) 1.1 kV Copper Control Cable (unarmoured for 132 kV bays) of sizes 7Cx4mm2, 4Cx4mm2, 2Cx4mm2, 2Cx6mm2, 16Cx2.5mm2, 10Cx2.5mm2, 7Cx2.5mm2 & 3Cx2.5mm2 including junction box etc. (Refer Section-6 for copper control cable specifications & Section-7 for Switchyard Erection)

1

-

-

... More
b) 1.1 kV Copper Control Cable (unarmoured for 33kV bays) of sizes 7Cx4mm2, 4Cx4mm2, 2Cx4mm2,2Cx6mm2, 16Cx2.5mm2, 10Cx2.5mm2, 7Cx2.5mm2 & 3Cx2.5mm2 including junction box etc. (Refer Section-6 for copper control cable specifications & Section-7 for Switchyard Erection).

1

-

-

... More
650/1100 Volts 3.5 core 240 mm2 aluminium power cable from Aux. T/F to ACDB

1

-

-

... More
650/1100 Volt 3.5 core 70 mm2 aluminium cable for oil filtration set.

1

-

-

... More
650/1100 Volt 4 core 16 mm2 copper power cable for MLDB and other cables required as per contract.

1

-

-

... More
Fire Fighting equipments as per section-6 as under: a) 22.5Kg Capacity FE CO2 type, Trolley Mounted

4

-

-

... More
b) 25Kg Capacity FE DCP type, Trolley Mounted

4

-

-

... More
c) DCP 9Kg Capacity , Wall Mounted

7

-

-

... More
d) FE CO2 6.5Kg Capacity, Wall Mounted

2

-

-

... More
e) DCP 6Kg Capacity , Wall Mounted

2

-

-

... More
f) Water CO2 9 Litre, Wall Mounted

2

-

-

... More
g) Fire Buckets (12 Nos. with stand in one set)

2

-

-

... More
Complete lighting of control room building, Switch yard area, road and street as per section 7 of the specification. a) Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area as per clause 16.0 of section 7 of the specifications.

23

-

-

... More
b) Supply and installation of 35W LED tube on tubular steel poles along with the boundary wall at a distance of 30 meter as per clause 16.0 of section 7 of the specification

23

-

-

... More
c) Complete lighting of road and street by providing 90W LED lamps on tubular steel poles at a distance of 15meter along the roads and streets as per clause 16.0 of section 7 of the specification.

11

-

-

... More
d) Supply and installation of post top lantern 40W LED Lamps with all complete accessories at the entrance gate of sub-station.

4

-

-

... More
e) Supply and installation of 40W LED Lamps with all complete accessories on corners of control room building.

4

-

-

... More
Earthing Mat Material. The earth mat will be designed/ quoted for soil resistivity of 50Ώm. In case soil resistivity is more than 50Ώm then the earth mat will be designed for actual soil resistivity. The payment of extra material to be used for earth mat shall be made on pro rata basis. The approximate area of earth mat to be laid is given in the corresponding columns of the substations. However, item will remain a Lot item. Earthmat area 16895 m2 (approx.)

1

-

-

... More
Computer System:- Computer System SFF with intel core i5,9th genration processor, 8 GB RAM, 1 TB HDD, 19.5" Display with UPS.

1

-

-

... More
Mono chrome Multi-functional printer, A-4, 25PPM, wi-fi

1

-

-

... More
Complete Substation automation system for 132/33kV substations including hardware (along with transducers) and software along with associated equipment for the bays (bay as defined in the technical specification, sec-sub-station automation system) (as per technical specification) as under: Present Future 132kV 33kV 132kV 33kV T/F 2 2 (I/C) 1 1 (I/C) Line 2 3 2 5 B/C 1 0 0 0 Capacitor 0 2 0 0

1

-

-

... More
High wall type split AC unit of 2 Ton capacity for SCADA room and specifically C&R Panel room (as per technical specification)

4

-

-

... More
Testing of IUM System at NABL accredited lab

1

-

-

... More
132 kV bolted type single suspension string assembly with 9 numbers ANTI FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for single Zebra ACSR. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators

24

-

-

... More
132 kV bolted type single suspension string assembly with 9 numbers ANTI FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for twin Zebra ACSR. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators

9

-

-

... More
132 kV bolted type single tension string assembly with 10 numbers ANTI FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and tension clamp set suitable for single zebra ACSR. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators

24

-

-

... More
132 kV bolted type single tension string assembly with 10 numbers ANTI FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and tension clamp set suitable for twin zebra ACSR. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators

30

-

-

... More
33 kV bolted type Single tension string assembly with 3 numbers ANTI FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and tension clamp sets suitable for twin Zebra ACSR. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators

30

-

-

... More
33 kV bolted type Single suspension string assembly with 3 number ANTI FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and tension clamp sets suitable for twin Zebra ACSR. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators

9

-

-

... More
Bolt less C-Type Wedge connectors matching with conductor size for single/twin zebra.

1

-

-

... More
Copper lugs glands & PVC ferrules for control cabling.

1

-

-

... More
Fibre cleats, Aluminium clamps, bolts, nuts, washers etc., for fixing control cables in trenches

1

-

-

... More
Galvanised iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 150x25x2mm, 100x25x2mm and 75x25x2 mm and GI conduits of 50mm/100mm dia from equipment to main trench as per Section-7 of switchyard erection.

1

-

-

... More
ACSR Zebra Conductor

3068

-

-

... More
7/3.15 GS Earthwire

400

-

-

... More
U-bolt 20mm dia

1

-

-

... More
Spacers for Twin Zebra conductor

1

-

-

... More
Mandatory spares for hardware/mechanical/Electrical auxiliaries to be supplied. 10 % of the finally approved quantities for item mentioned from Sr. No. 60 to 65.

1

-

-

... More
2.5” dia HDD/PVC pipe for 4Cx4mm2 control cable from CTs, VT to metering system as per section-5, chapter-5.

1

-

-

... More
Item for associated structure work ‘Lattice type steel structure for 132kV S/Stn. Sangroli. Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 132/33KV switchyard fabricated from steel conforming to IS:2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner. Main S/Stn. tower and beam a) Tower type BT-1

5

-

-

... More
b) Tower type BT-3

6

-

-

... More
c) Tower type BT-4

3

-

-

... More
d) Tower type BT-6

6

-

-

... More
e) Beam type BB-1

11

-

-

... More
f) Beam type BB-2

6

-

-

... More
g) Tower type DT-2

7

-

-

... More
h) Tower type DT-3

8

-

-

... More
i) Beam type DB-2

8

-

-

... More
Equipment Structure a) 132 kV CT drg. No. HHW/ST-67

15

-

-

... More
b) 132 kV PT/CVT drg. No. HHW/ST-67

6

-

-

... More
c) 132 kV Surge Arrestor drg. No. HSW/ST-63R

12

-

-

... More
d) 132kV Bus Post Insulator drg.No.HTD/ST-144

10

-

-

... More
e) 132 kV Isolator/L&E drg. No. HTD/ST-90 R3

12

-

-

... More
f) 132 kV NCT drg. No. HTD/ST-145

2

-

-

... More
g) 33 kV LA drg. HTD/ST-89R

21

-

-

... More
h) 33 kV CT drg. HTD/ST-88

21

-

-

... More
i) 33 kV Isolator/L&E drg. HTD/ST-110

14

-

-

... More
j) 33 kV NCT drg. HTD/ST-88

2

-

-

... More
k) 33 kV PT drg. HTD/ST-88

6

-

-

... More
EARTH WORK Earth filling with good earth (as per satisfaction of Engineer incharge), laying in layers (as per specification), dressing, including carriage, irrespective of lead, loading, unloading, watering and compaction in layers with roller including compensation of earth complete in all respect.

42000

-

-

... More
FOUNDATIONS Supply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications & drawings attached with the tender document including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc. and other items not mentioned herein but required for the completion of work. A. GANTRY TOWERS (NGL-FGL Difference upto 2.50M) i) BT-1

5

-

-

... More
ii) BT-3

6

-

-

... More
iii) BT-4

3

-

-

... More
iv) BT-6

6

-

-

... More
v) DT-2

5

-

-

... More
vi) DT-3

7

-

-

... More
B. EQUIPMENT 132kV side i) LA

12

-

-

... More
ii) CVT/PT

6

-

-

... More
iii)CT

15

-

-

... More
iv) Post Insulator

10

-

-

... More
v)Isolator & L&E

12

-

-

... More
vi) NCT

2

-

-

... More
33kV side i) LA

12

-

-

... More
ii) PT

6

-

-

... More
iii) CT

18

-

-

... More
iv) Isolator & L&E

11

-

-

... More
v) NCT

2

-

-

... More
Design engineering, supply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc. and other items not mentioned herein but required for the completion of work. A. GANTRY TOWERS (NGL-FGL Difference more than.50M) i) DT-2

2

-

-

... More
ii) DT-3

1

-

-

... More
B. Equipments (NGL-FGL Difference more than.50M) i) 33 kV LA

9

-

-

... More
ii) 33 kV CT

3

-

-

... More
iii) 33 kV Isolator & L&E

3

-

-

... More
BREAKER FOUNDATION Design, engineering, supply of labour, material for construction of breaker foundations including all associated works such as PCC, RCC, structural steel, steel reinforcement, form work etc. or any other items not specifically mentioned herein but required for completion of work as per approved equipment(s) and technical specifications. i. 132kV, SF-6 Breaker

5

-

-

... More
ii. 33kV VCB

7

-

-

... More
CAPACITOR BANK FOUNDATIONS Design, Engg. & supply of labour, material & construction of foundations for capacitor bank with capacitor unit & series Reactor etc. including chain link fencing 1.8M height around cap. bank complete in all respect including any other items not specifically mentioned herein but required for completion of job as per technical specification. i) 5.43 MVAR 33kV Capacitor Bank

1

-

-

... More
ii) 10.872 33 kV rating Capacitor bank foundation

1

-

-

... More
TRANSFORMER FOUNDATION Supply of labour, material and construction of T/F foundation including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications. In case additional foundation is/are required as per approved equipment drawing, the same shall be constructed by the successful bidder without any extra cost to HVPNL. Such drawing(s) shall, however, be got approved from HVPNL. i) 40/50MVA 132/33kV T/F foundation.

1

-

-

... More
ii) 20/25 MVA, 132/33kV T/F foundation.

1

-

-

... More
Design, Engg., supply of labour, T&P and material including RCC, PCC, Reinforcement steel, misc. structural steel & other item(s) not mentioned herein but required for the completion of work as per tech. specs. for construction of below mentioned foundations. 200KVA 33/0.4 KV Station T/F

1

-

-

... More
CABLE TRENCHES Supply of labour, material such as cement, reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works like Cable Trench Culverts crossings for roads and sumpit-cum-pump chamber with 2HP motor of reputed make, starter, volt meter, amp-meter etc. as per attached foundation & trench layout plan, HVPNL drgs. & tech. specs. complete in all respect. i) D-type Trench

275

-

-

... More
ii)E-type Trench

155

-

-

... More
iii) F-type Trench

26

-

-

... More
iv) G-type Trench

110

-

-

... More
v) H-type Trench

45

-

-

... More
vi) Road Crossing

1

-

-

... More
vii) Sump pit cum pump chamber

1

-

-

... More
SITE SURFACING i.Providing, supplying & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and supplying & spreading 100mm thick layer of 40mm nominal size uncrushed/ crushed/broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm single size uncrushed/ crushed /broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of engineer incharge.

4200

-

-

... More
ii. Providing, supplying & laying 100mm thick in two layers of 50mm each of 20mm nominal size uncrushed/crushed/ broken stone pebbles gravel fill including dressing, rolling & compacting complete in all respects as per specs. & instructions of engineer incharge.

300

-

-

... More
ROADS & PCC PAVEMENT Supply of labour, material and construction of cement concrete roads and walkways/shoulders from NH/SH/etc. to Switch yard/Switch house building as per GELO/CLO as per sectional detail drawing no. HCD/SK-181 R1 and technical specification. i) 6.0M wide road (Near main gate of substation)

15

-

-

... More
ii) 3.66M wide road within substation

190

-

-

... More
iii) PCC in front and rear of parking area of SH Building as per tech. specification and drawing HCD/SK-172.

300

-

-

... More
ROAD CULVERTS Design, Engineering and const. of Pipe culvert(s) at suitable locations under the approach road (from main PWD/ HUDA/Municipal/Village road to the sub-station entry point) including, cost of labour, material complete in all respects as per I.R.C. Standards.

1

-

-

... More
BOUNDARY WALL Supply of labour, material and construction of front, C & U/C boundary walls above DPC including main gate foundations as per GELO/CLO, technical specifications. & HVPNL drg. HCD/TS-1176 R3 including DPC complete in all respect. i) 6 ft. high with GI barbed wire on angles at top.

595

-

-

... More
ii) 4½ ft. high front wall including providing with grill at top of wall and construction of gate pillars .

40

-

-

... More
iii) Supply of labour, T&P, material & construction of front, side & U/C boundary walls (brickwork below DPC level) as per GELO/CLO, tech. spec. & HVPNL drgs including excavation, PCC, back filling etc. complete in all respects.

1708

-

-

... More
U/C FENCING & GATES Providing & fixing chain link fencing including foundations, GI angle iron posts and gate(s) complete as per electrical layout & tech. spec. & as per drawing attached.

120

-

-

... More
CONTROL ROOM BUILDING Supply of labour, material, T&P and construction of control room building complete in all respect as per tech. specs. & approved drgs. attached with the bid/tendered drawings including exterior weather proof paint, interior emulsion, all internal services like water supply including supply & providing of 5000ltr. capacity double layer Sintex/Diplast PVC tank, Sewerage system, electrification including wiring, modular switches, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens, ceiling/exhaust fans, Finishing, Plinth protection, closed drain around the building (i.e RCC Pipe), Indoor trenches, Soakage pit near the switch house building, connection of sewerage system to Soakage pit/Sewerage system of local authorities (as applicable), connection to main water supply system of local authority, bore (Tubewell) (as applicable) etc. & any other item not mentioned herein but required for completion of works.

4743

-

-

... More
DRAINAGE–CUM-RAIN HARVESTING SYSTEM i. Supply of labour, material for construction of recharge structures with bore well(s) as per HVPN drawings & specs. complete in all respect. The location of recharge structures shall preferably be located on corner(s) of the substation and shall be got decided from the concerned XEN/Civil Works Division on the basis of surroundings of the substation(s). In case ground water table is less than 8m from FGL, rain harvesting well shall not be constructed (the drainage system with sump pit is to be constructed as per item mentioned below).

3

-

-

... More
ii. The successful bidder shall evolve design & drawing for drains, manholes with RCC covers and settlement tank including preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into respective bore well(s) in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be located on corner(s) of the s/stn. and shall be got decided from Engineer-incharge on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of sump-pit-cum-pump chamber as per HVPNL drgs. & provide one no. non clog pump(s) of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. (for each sump pit) for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer. i) Drain Section-1

350

-

-

... More
ii) Drain Section-2

200

-

-

... More
iii) Drain Section-3

100

-

-

... More
iv) Road Crossing

1

-

-

... More
v) Trench Crossing

1

-

-

... More
vi) Sump Pit Cum Pump Chamber

3

-

-

... More
RCC M-20 inclusive of labour, material, shuttering, Steel reinforcement etc. complete in all respects to compensate excess quantity required to be executed due to difference in existing natural ground level and the formation level to be fixed after contouring or difference on account of revised drawing issued at the time of construction and the tender drawing. However, the item of extra RCC shall not be applicable for the drawings which has to be evolved by the successful bidder.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.