Haryana Vidyut Prasaran Nigam Limited Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 67,92,000Document Cost
₹ 11,800Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_HBC_223290_1Bid Award Id
ViewTender No
EPC-D-52/PD AND CTender Authority
Haryana Vidyut Prasaran Nigam Limited ViewPurchaser Address
-Website
http://http://www.hvpn.org.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
ii) +6m extn. Only
11
-
-
132kV D/C “DB” KRR Design type Tower
9
-
-
i) +3m extn. Only
5
-
-
ii) +6m extn. Only
2
-
-
132kV D/C “DC” KRR Design type Tower
1
-
-
i) +3m extn. Only
1
-
-
132kV D/C “DD” KRR Design type Tower
4
-
-
i) Extra Cross Arm Only (Set of 3)
2
-
-
66 kV D/C ‘DA’ (KRR Design)
33
-
-
i) +3m extn. Only
8
-
-
ii) +6m extn. Only
2
-
-
66 kV D/C ‘DB’ (KRR Design)
12
-
-
i) +3m extn. Only
2
-
-
ii) +6m extn. Only
2
-
-
66 kV D/C ‘DC’ (KRR Design)
4
-
-
i) +3m extn. Only
2
-
-
66 kV D/C ‘DD’ (KRR Design)
19
-
-
i) +3m extn. Only
4
-
-
ii) +6m extn. Only
2
-
-
iii) Aux-cross arm only (set of 3)
2
-
-
i) 66kV D/C Gantry (KRR Design)
6
-
-
220kV M/C 'MD' Special Extn tower KRR Design (+15m )
2
-
-
i) Aux-cross arm only (set of 6)
1
-
-
220kV DB+6 type Tower (TATA. Design)
1
-
-
220kV DD+6 type Tower (TATA. Design)
1
-
-
220kV DD+9 type Tower (TATA. Design)
1
-
-
Design, Fabrication, Supply, Erection & Commissioning of 66kV S/C Monopoles with Foundation (Raft/ Pier/ Pile) & bolts & nuts, step bolts, U-bolts, D-shackle etc. of Monopole shall be duly approved from CPRI/SERC/IITs.
(Bottom Cross-arm height/Availability of maximum space)
i) 66kV S/C PB_(20-150) complete set with all cross arm on one side i.e. same side as per site requirement (13m/2.5m)
1
-
-
ii) 66kV S/C PD_(300-600) complete set with all cross arm on one side i.e. same side as per site requirement (13m/2.5m)
1
-
-
iii) 66kV S/C PE_(600-900) complete set with all cross arm on one side i.e. same side as per site requirement (13m/2.5m)
1
-
-
Supply of Earthing of towers i) Pipe type
126
-
-
Supply of following Tower accessories i) Danger Plate
123
-
-
ii) Number Plate
123
-
-
iii) Phase Plate (set of 3)
143
-
-
iv) Phase Plate (set of 6)
14
-
-
v) Circuit Plate (set of 2)
120
-
-
v) Circuit Plate
134
-
-
vi) Bird Guard (set of 3)
162
-
-
vii) Anti climbing device
123
-
-
LINE MATERIAL Conductor (ACSR Zebra) (approx.)
120.3
-
-
Conductor (0.2 sq inch ACSR Panther)(approx.)
84
-
-
Earthwire (7/3.15 mm)
0.25
-
-
Earthwire (7/2.5 mm)
0.31
-
-
*132KV Anti-Fog type Disc Insulator or 132KV Silicon Rubber Polymer Insulator strings i) 70 kN
324
-
-
ii) 90 kN
426
-
-
iii) 120 kN
144
-
-
132 kV post insulators
42
-
-
66kV Anti fog or Silicon Rubber Polymer Insulator strings *
i) 70kN
240
-
-
ii) 90kN
24
-
-
iii) 120kN
552
-
-
Hardware Fittings for ACSR Zebra Conductor
i. Single ‘I’ Suspension String
279
-
-
ii. Single Suspension Pilot String
51
-
-
iii. Single Tension String
612
-
-
iv. Double Tension String
42
-
-
Hardware Fittings for Panther Conductor (a) Single 'I' Suspension string
207
-
-
(b) Single Suspension pilot string
27
-
-
(c) Single Tension String
342
-
-
(d) Double Tension String
42
-
-
Conductor (ACSR Zebra) & Earth wire Accessories i) Mid Span Compression Joint for ACSR Zebra Conductor
80
-
-
ii) Repair sleeves for ACSR Zebra Conductor
24
-
-
iii) Vibration damper for ACSR Zebra Conductor
1878
-
-
iv) Flexible copper Bond
9
-
-
v) Vibration damper for earthwire
14
-
-
vi) Earth-wire Tension clamp
12
-
-
Conductor (ACSR Panther) Accessories i) Mid Span Compression Joint for conductor
57
-
-
ii) Repair Sleeves for conductor
18
-
-
iii) Vibration damper for conductor
1182
-
-
Hardware Fittings of HTLS Lavender type Conductor (size equivalent to ACSR Wolf Conductor) having current carrying capacity of about 600 Amp
(a) Single Tension string
14
-
-
(b) Double tension string
8
-
-
HTLS Lavender type conductor (size equivalent to ACSR Wolf Conductor) having current carrying capacity about 600A Accessories
i) Mid Span Compression Joint for conductor
2
-
-
ii) Repair sleeves for conductor
2
-
-
iii) Vibration damper for conductor
38
-
-
Earthwire (7/2.5mm) Accessories
i) Flexible Copper Bond
3
-
-
ii) Vibration Damper for Earth Wire
12
-
-
iii) Earth Wire Tension Clamp
6
-
-
C-Wedge Connector
12
-
-
OPGW (24 Fiber) (equivalent to Earth Wire: 7/3.15mm in all respect)
25.5
-
-
Hardware Set for above 24 OPGW Fiber Optic (equivalent to Earth Wire: 7/3.15mm in all respect) cabling including all cable fitting & accessories except joint box.
25.5
-
-
UGFO (Underground Fiber Optic) Cable (24 fiber) in DWSM along with GI ducts of suitable size & strength and all asseccories for underground portion of the line with suitable chamber & trenches.
2.5
-
-
FODP 48F: Indoor type, rack mounted with FCPC Coupling and pig tails (5mtrs, each) as applicable.
3
-
-
Joint Box 24 Fiber OPGW to OPGW (Quantity may varies as per drum schedule of OPGW)
9
-
-
Joint Box (24 fiber) OPGW to UGFO (as applicable) (Quantity may varies as per drum schedule of OPGW)
1
-
-
Joint Box 24 Fiber OPGW to FOAC
4
-
-
Fiber Optic Approach Cable, 24 fiber (DWSM) along with PLB HPE Ducts of suitable size & strength and all accessories
2.5
-
-
Wideband Communication equipment Telecom Equipment as required SDH Equipment (STM - 16 MADM upto 5 MSP protected directions)
Base Equipment (Common cards, Cross connect/control cards, optical base cards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc. fully equipped excluding (45.1) to (46.3) below to be installed.
2
-
-
Optical Interface Cards/SFP S16.1 SFP (The quantities will be decided at the time of detailed engineering)
4
-
-
S4.1 SFP (The quantities will be decided at the time of detailed engineering)
4
-
-
Tributary cards
E1 Interface card ( Min. 32 interfaces per card)
4
-
-
Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card)
4
-
-
Gigabit Ethernet (Layer 2) Interface (min. 2 nos.)
2
-
-
Equipment Cabinet with DDF and all installation accessories
2
-
-
Network Manager System - Craft Terminal
Hardware
2
-
-
Software
2
-
-
VOIP telephone instrument with one common switch (min. 8 port) compatible with SLDC
3
-
-
Integration of the Equipment with existing network
Note:- Above Quantities (Telecom equipments) covers the requirement of remote station as well.
3
-
-
Mandatory Spares:
Optical Interface Cards/SFP
S16.1 SFP (The quantities will be decided at the time of detailed engineering)
2
-
-
S4.1 SFP (The quantities will be decided at the time of detailed engineering)
2
-
-
Tributary cards
E1 Interface card (Min. 32 interfaces per card)
2
-
-
Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card)
2
-
-
Gigabit Ethernet (Layer 2) Interface (min. 2 nos.)
2
-
-
VOIP telephone instrument with one common switch (min. 8 port) compatible with SLDC
1
-
-
Pre Connectorized Optical Patch Cards (10Mtrs.) – Pack of six Patch Cards
2
-
-
Any other item/items left out but required to complete the work
2
-
-
Erection of HTLS lavender type conductor (size equivalent to ACSR Wolf conductor) having current carrying capacity of about 600 Amp
( HTLS lavender type conductor will be supplied by HVPNL)
0.93
-
-
DISMANTLEMENT WORK to be included in Erection Part of BOQ Dismantlement of towers and their transportation & proper stacking at any dedicated store of HVPNL. The dismantlement of tower shall also include dismantlement of Stub concrete up to a depth of 1M (one meter) from Natural Ground level, back filling, compaction and clearing the site of debris a)220kV D/C DA+6 type tower TATA Design
1
-
-
Dismantlement of existing ACSR Zebra conductor complete with fittings and accessories and their transportation proper stacking at any dedicated store of HVPNL.
1.5
-
-
Dismantlement of existing earthwire complete with fittings and accessories for above portion of line and their transportation proper stacking at any dedicated store of HVPNL.
0.25
-
-
DISMANTLEMENT WORK to be included in Erection Part of BOQ
i) Dismantlement of towers and their transportation & proper stacking at any dedicated store of HVPNL. The dismantlement of tower shall also include dismantlement of Stub concrete upto a depth of 1M (one meter) from Natural Ground level, back filling , compaction and clearing the site of debris 132kV S/C “C” type Tower (HSEB Design)
1
-
-
66kV S/C “C” type Tower (HSEB Design)
1
-
-
66kV S/C “A” type Tower (HSEB Design)
1
-
-
ii) Dismantlement of existing HTLS Conductor size equivalent to ACSR Wolf Conductor & Earthwire (7/2.5mm) complete with H/W fittings for above portion of line and their transportation proper stacking at any dedicated store of HVPNL.
0.31
-
-
Detailed Survey
27.7
-
-
Furnishing bore log data
28
-
-
Construction of tower foundations as per HVPNL Drgs& Specs for 0 to 6Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect.
i) 132kV D/C 'DA' type Tower (KRR Design) classified as - Wet (w/out de-watering)
27
-
-
ii) 132kV D/C 'DB' type Tower (KRR Design) classified as - Wet (w/out de-watering)
9
-
-
iii) 132kV D/C 'DC' type Tower (KRR Design) classified as - Wet (w/out de-watering)
1
-
-
iv) 132kV D/C 'DD' type Tower (KRR Design) classified as - Dry
2
-
-
- Wet (w/out de-watering)
2
-
-
Construction of tower foundations as per HVPNL Drgs& Specs for 0 to 09 Mtr. extn. including excavation, concreting, supply and placement of steel Reinforcement/Material and backfilling completed in all respect.
i) 66kV D/C 'DA' type Tower (KRR Design) classified as - Dry
10
-
-
- Wet (w/out de-watering)
23
-
-
ii) 66kV D/C 'DB' type Tower (KRR Design) classified as - Dry
4
-
-
- Wet (w/out de-watering)
8
-
-
iii) 66kV D/C 'DC' type Tower (KRR Design) classified as - Dry
2
-
-
- Wet (w/out de-watering)
2
-
-
iv) 66kV D/C 'DD' type Tower (KRR Design) classified as - Dry
10
-
-
- Wet (w/out de-watering)
9
-
-
Construction of 66kV D/C gantry foundation as per KRR Design (3 no. footings in one set ) including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect.
6
-
-
Construction of tower foundations as per HVPNL Drgs& Specs for above 06 Mtr. extn. including excavation, concreting, supply and placement of steel Reinforcement/Material and backfilling completed in all respect.
i) 220 kV MC 'MD+15 Mtr' type Tower (KRR Design) classified as - Wet (w/out de-watering)
2
-
-
Construction of tower foundations as per HVPNL Drgs & Specifications for 0 to 6Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect.
i) 220kV D/C 'DB' type Tower (TATA Design) classified as - Wet (w/out de-watering)
1
-
-
ii) 220kV D/C 'DD' type Tower (TATA Design) classified as - Wet (w/out de-watering)
1
-
-
Construction of tower foundations as per HVPNL Drgs & Specifications for above 06 Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect.
i) 220kV D/C 'DD' type Tower (TATA Design) classified as - Wet (w/out de-watering)
1
-
-
Dewatering of subsoil water for lowering of water table to enable excavation of earth, concreting for foundations/stub and backfilling, by boring of tube wells or deploying well point system so that continuous lowering of water table is made till completion of work, without disturbing the soil characteristics. The rate shall include all type of expenditure for required dewatering arrangements and irrespective of type of tower including extensions if any i.e. KRR design or TATA design.
7
-
-
Protection Measure Brick masonry in 1:4 cement sand mortar including excavation
8
-
-
Earth filling, compaction, leveling etc inside revetments
7
-
-
M-20 (1:1½ :3 mix) concrete for top seal cover, for revetment etc.
5
-
-
Lean concrete (1:3:6)
1
-
-
Lean concrete (1:4:8)
6
-
-
RCC 1:1.5:3 (M20) including all material, labour, excavation, cutting and placing of steel, centering & shuttering, concreting etc. complete in all respect.
14
-
-
Supply of 1200 mm2 aluminium Milliken conductor 66 KV XLPE cable as per technical specification
19136
-
-
Detailed Survey (tentative route length: 2322mtr.) Laying, Testing & Commissioning of Double Circuit 1200 mm2 aluminium Milliken conductor 66 KV XLPE cable including loops and riser in Trefoil formation (with FRP trefoil clamp) with one spare cable for each circuit (6+2) and Civil works complete in all respect including Manholes for jointing Bays as per site requirement, on through rate basis as per technical specification with open cut method of laying of cable in ground (tentative length of directly buried cable (2322m), length of loops and riser (20+10+15=45m) Total 2322+45=2367m)
18936
-
-
Detailed Survey (tentative route length: 25mtr.) Laying, Testing & Commissioning of Double Circuit 1200 mm2 aluminium Milliken conductor 66 KV XLPE cable with HDPE Pipe in Trefoil formation with one spare cable for each circuit (6+2) on through rate basis as per technical specification with trenchless method Note:-The erection/ laying of HDPE pipe is to be quoted at Sr. no 80) below for road crossing only
200
-
-
Supply and Erection /Laying of HDPE pipe required for various crossings as per detail at Sr. no. 79 above
200
-
-
Supply, Erection, Testing & Commissioning of Outdoor End Terminations as per technical specification suitable for above cable as per bidder’s standard design
8
-
-
Indicative quantity for supply, Erection, Testing & Commissioning of single phase Link Box with SVL for each cable (to be decided as per requirement)
8
-
-
Indicative quantity for supply, Erection, Testing & Commissioning of single phase Link Box with-out SVL for each cable (to be decided as per requirement)
8
-
-
Indicative quantity of Supply, Erection, Testing & Commissioning of 3 Phase Link Box at cross bonding point with SVL for each circuit (to be decided as per requirement)
1
-
-
Indicative quantity of Supply, Erection, Testing & Commissioning of 3 Phase Link Box at cross bonding point with-out SVL for each circuit (to be decided as per requirement)
1
-
-
Indicative quantity of Supply, Erection, Testing & Commissioning of 1 x 240mm2, Copper Conductor, PVC insulated, Unarmoured, 3.3 KV Sheath Bonding cable (to be decided as per requirement)
200
-
-
Supply, Erection, Testing & Commissioning of 60 kV Polymeric LAs with surge counter, earthing material complete in all respects as per Latest relevant standard and technical specification of HVPNL.
6
-
-
Supply, Erection, Testing & Commissioning of Straight Through Joints
24
-
-
Supply, Erection, Testing & Commissioning of Terminal Connectors including Hardware fittings for ACSR Zebra conductor etc.
6
-
-
Supply and Erection of Warning Tape
4644
-
-