Haryana Vidyut Prasaran Nigam Limited Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 40,23,000Document Cost
₹ 11,800Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_HBC_170016_1Bid Award Id
ViewTender No
EPC-D-21/PD and CTender Authority
Haryana Vidyut Prasaran Nigam Limited ViewPurchaser Address
-Website
http://http://www.hvpn.org.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
132kV DB type tower (K.R.R. Design)
29
-
-
+3 mtr. extn. Only
13
-
-
+6 mtr. extn. Only
3
-
-
i) 132kV DC type tower (K.R.R. Design)
17
-
-
+3 mtr. extn. only
7
-
-
+6m extn. Only
1
-
-
132kV DD type Tower (K.R.R. Design)
40
-
-
+3 mtr. extn. only
4
-
-
+6 mtr. extn. only
5
-
-
+9 mtr. extn. only
4
-
-
+12 mtr. extn. Only
2
-
-
+18 mtr. extn. only
2
-
-
Extra cross arm(Set of 3)
2
-
-
132kV D/C Gantry (K.R.R. Design)
6
-
-
Supply of earthing of Towers/ Gantry
Pipe type
170
-
-
Supply of following Tower accessories
Danger Plate
170
-
-
Number Plate
170
-
-
Phase Plate(set of 3)
114
-
-
Circuit Plate (set of 2)
195
-
-
Anti climbing device
170
-
-
Bird guard (set of 3)
92
-
-
Conductor: ACSR Zebra conductor
141
-
-
Conductor: ACSR Panther conductor
6.3
-
-
Earthwire: 7/3.15mm
24.05
-
-
A/F type Disc Insulator or 132 kV Silicon Rubber Polymer Insulator strings: 70 kN
305
-
-
120kN
692
-
-
132kV Post Insulators
16
-
-
Hardware Fittings of ACSR Zebra conductor
Single ‘I’ Suspension String
264
-
-
Single suspension pilot string
32
-
-
Single Tension string
532
-
-
Double tension string
50
-
-
Hardware Fittings of ACSR Panther conductor
Single ‘I’ Suspension String
6
-
-
Single suspension pilot string
3
-
-
Single Tension string
60
-
-
Conductor (ACSR Zebra) & Earth wire Accessories((7/ 3.15 mm)) Mid Span Compression Joint for conductor
94
-
-
Mid Span Compression Joint for earth wire(7/3.15mm)
16
-
-
Flexible copper bond
92
-
-
Repair sleeves for conductor
28
-
-
Repair sleeves for earthwire
6
-
-
Vibration damper for earthwire
272
-
-
Vibration damper for Zebra conductor
1692
-
-
Earth wire Tension Clamp for Earthwire (7/3.15mm)
78
-
-
Earth wire Suspension Clamp for Earthwire (7/3.15mm)
48
-
-
Conductor (ACSR Panther) & Earth wire Accessories((7/ 3.15 mm)) Mid Span Compression Joint for conductor
5
-
-
Repair sleeves for conductor
2
-
-
Vibration damper for Panther conductor
132
-
-
OPGW (24 Fiber) (DWSM, G.652D) (equivalent to Earth Wire: 7/3.15 mm in all respect)
27
-
-
Hardware Set for above 24 OPGW Fiber Optic (equivalent to Earth Wire: 7/3.15 mm in all respect) cabling including all cable fitting & accessories except joint box
27
-
-
FODP 48F: In door type, rack mounted with FCPC Coupling and pig tails (5mtrs, each)
5
-
-
Joint Box 24 Fiber OPGW to OPGW (as applicable) (Quantity may varies as per drum schedule of OPGW)
8
-
-
Joint Box 24 Fiber OPGW to FOAC
5
-
-
Fiber Optic Approach Cable, 24 fiber (DWSM) along with PLB HPE Ducts of suitable size & strength and all accessories
3
-
-
Wideband Communication equipment and spares Base/Telecom Equipment SDH Equipment (STM - 16 MADM upto 5 MSP protected directions) base Equipment (Common cards, Cross connect/control cards, optical base cards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc. fully equipped excluding (ii) & (iii) below
3
-
-
Optical Interface Cards/SFP S16.1 SFP (The quantities will be decided at the time of detailed engineering)
8
-
-
L16.2 SFP (The quantities will be decided at the time of detailed engineering)
8
-
-
S4.1 SFP (The quantities will be decided at the time of detailed engineering)
8
-
-
Tributary cards E1 Interface card ( Min. 32 interfaces per card)
6
-
-
Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card)
6
-
-
Gigabit Ethernet (Layer 2) Interface (min. 2 nos.)
3
-
-
Equipment Cabinet with DDF and all installation accessories
3
-
-
Network Manager System - Craft Terminal Hardware
2
-
-
Software
2
-
-
VOIP telephone instrument with one common switch(min. 8 port) compatible with SLDC
2
-
-
Integration of the Equipment with existing network
2
-
-
Mandatory Spares Telecom Equipment SDH Equipment (STM - 16 MADM up to 5 MSP protected directions) Optical Interface Cards SFPS16.1 SFP (The quantities will be decided at the time of detailed engineering)
4
-
-
L16.2 SFP (The quantities will be decided at the time of detailed engineering)
4
-
-
S4.1 SFP (The quantities will be decided at the time of detailed engineering)
4
-
-
Tributary cards E1 Interface card ( Min. 32 interfaces per card)
2
-
-
Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card)
2
-
-
Gigabit Ethernet (Layer 2) Interface (min. 2 nos.)
2
-
-
Pre Connectorized Optical Patch Cards (10Mtrs.) – Pack of six Patch Cards
2
-
-
DISMANTLEMENT & THEREAFTER ERECTION WORK TO BE INCLUDED IN ERECTION PART OF BOQ Dismantelement of existing earthwire of size 7/3.15mm of 220KV Bhadana-132KV Jhajjar complete with fiting and accessories for above portion of line and their transportation proper stacking at any dedicated store of HVPNL.
7
-
-
Detailed Survey
42.31
-
-
Furnishing bore log data
47
-
-
(A) Construction of tower foundations as per HVPNL Drgs & Specs for 0 to 6M extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. i) 132 kV D/C ‘DA’ type tower (KRR Design) classified as - Dry
32
-
-
Wet (w/out de-watering)
46
-
-
132 kV D/C ‘DB’ type tower (KRR Design) classified as - Dry
11
-
-
Wet (w/out de-watering)
18
-
-
132 kV D/C ‘DC’ type tower (KRR Design) classified as - Dry
9
-
-
Wet (w/out de-watering)
8
-
-
132 kV ‘DD’ type tower (KRR Design) classified as- - Dry
8
-
-
Wet (w/out de-watering)
24
-
-
Construction of tower foundations as per HVPNL Drgs & Specs for 9 to 25M extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. 132kV D/C ‘DD+18m extension type tower (KRR Design) classified as- Dry (Drwaing & Quantity as per Annexure-A)
2
-
-
Construction of tower foundations as per HVPNL Drgs & Specs for 9 to 25M extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. 132kV D/C ‘DD+9m, DD+12m extension type tower (KRR Design) classified as- Wet (w/out de-watering) (Drwaing & Quantity as per Annexure-A)
6
-
-
Dewatering of subsoil water for lowering of water table to enable excavation of earth, concreting for foundations/stub and backfilling, by boring of tube wells or deploying well point system so that continuous lowering of water table is made till completion of work, without disturbing the soil characteristics. The rate shall include all type of expenditure for required dewatering arrangements and irrespective of type of tower i/c extensions if any i.e. KRR design or TATA design
77
-
-
Construction of 132kV D/C gantry foundations as per KRR Desing one set of T-1 & T-2(3 no. of footings in one set ) including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect.(Drawing & Quantity as per Annexure -A)
6
-
-
Protection Measure Brick masonry in 1:4 cement sand mortar including excavation
7
-
-
Earth filling, compaction, leveling etc inside revetments
7
-
-
M-20 (1:1½ :3 mix) concrete for top seal cover, for revetment etc.
4
-
-
Lean concrete (1:4:8)
4
-
-
RCC 1:1.5:3 (M20) including all material, labour, excavation, cutting and placing of steel, centering & shuttering, concreting etc. complete in all respect.
16
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements