Haryana Vidyut Prasaran Nigam Limited Tender
... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 16,27,000Document Cost
₹ 11,800Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_HBC_112883_1Bid Award Id
ViewTender No
EPC-D-277Tender Authority
Haryana Vidyut Prasaran Nigam Limited ViewPurchaser Address
-Website
http://http://www.hvpn.org.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
36kV, 2000A, single 3 – or three 1 –, Transmission line feeder circuit breaker bay modules, consisting of 2000A single 3 – or three 1 – SF6 gas insulated switchgears, each comprising of:-
i)2000A, One 3 – or three 1 –, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for outgoing feeder.
ii) Three, 2-core, single phase current transformers (2000-1000/5-1A) iii) 2000A, One 3 – or three 1 – , single pole, group operated isolator/disconnector with one, 3 – or three 1 – , single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.
iv) 2000A, One 3 – or three 1 – , single pole, group operated isolator/disconnector with one normal 3 – or three 1 – , single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms
v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.
vi) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.
vii) Interconnecting wiring/ piping.
viii) Grounding, support structures and platforms.
ix) Set of Surge Arrestors & Voltage Detectors
1
-
-
... More
36kV, 630A, single 3 – or three 1 –, Transmission line feeder circuit breaker bay modules, consisting of 630A single 3 – or three 1 – SF6 gas insulated switchgears, each comprising of:-
i) 630A, One 3 – or three 1 –, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for outgoing feeder.
ii) Three, 2-core, single phase current transformers (400-300/5-1A)
iii) 630A, One 3 – or three 1 – , single pole, group operated isolator/disconnector with one, 3 – or three 1 – , single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.
iv) 630A, One 3 – or three 1 – , single pole, group operated isolator/disconnector with one normal 3 – or three 1 – , single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms
v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.
vi) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.
vii) Interconnecting wiring/ piping.
viii) Grounding, support structures and platforms.
ix) Set of Surge Arrestors & Voltage Detectors
8
-
-
... More
36 kV, 630A, 31.5 kA for 3 sec, SF6 gas insulated Capacitor Bay Modules, consisting of 630A single 3 – or three 1 –, SF6 gas insulated switchgears, each comprising of:-
i) 630A, One 3 – or three 1 –, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for outgoing feeder.
ii) Three, 2-core, single phase current transformers (400-300/5-5A)
iii) 630A, One 3 – or three 1 – , single pole, group operated isolator/disconnector with one, 3 – or three 1 – , single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.
iv) 630A, One 3 – or three 1 – , single pole, group operated isolator/disconnector with one normal 3 – or three 1 – , single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.
v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.
vi) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc. vii) Interconnecting wiring/ piping.
viii) Grounding, support structures and platforms.
ix) Set of Surge Arrestors & Voltage Detectors
1
-
-
... More
36 kV, 630A, 31.5 kA for 3 sec, SF6 gas insulated S/Stn Transformer Bay Modules, consisting of 630A single 3 – or three 1 –, SF6 gas insulated switchgears, each comprising of:- i) 630A, One 3 – or three 1 –, SF6 gas insulated vaccum circuit breaker, complete with operating mechanism for outgoing feeder.
ii) Three, single phase 2-core current transformers (60-30/5-1A)
iii) 630A, One 3 – or three 1 – , single pole, group operated isolator/disconnector with one, 3 – or three 1 – , single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.
iv) 630A, One 3 – or three 1 – , single pole, group operated isolator/disconnector with one 3 – or three 1 – , single pole, group operated earthing switches complete with manual and motor driven operating mechanisms
v) Each GIS compartment with gas monitoring device, pressure switch etc. as required.
vi) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc. vii) Interconnecting wiring/ piping.
viii) Grounding, support structures and platforms.
ix) Set of Surge Arrestors & Voltage Detectors
1
-
-
... More
33kV XLPE copper Cable 6X1C (1000mm2) for connecting 33kV side of each I/C of 220/33kV transformer with GIS with termination kit for both end for all Twelve cables. (two cables shall be used in each phase for each I/C, i.e. 2 Runs per phase x 3 no. Phase x 2no. I/C)
2100
-
-
... More
Single phase Termination kit for both end for 33kV XLPE copper Cable (1cx1000mm2)
12
-
-
... More
100 MVA 220/33 kV Power T/F along with10% extra T/F oil (will be provided by HVPNL)
1
-
-
... More
NIFPES for 220/33 kV Power T/F (will be provided by HVPNL)
1
-
-
... More
33kV XLPE copper Cable (3cx300m2) for connecting 33kV capacitor bank bay
250
-
-
... More
Three phase Termination kit for both end for 33kV XLPE copper Cable (3cx300mm2)
2
-
-
... More
33kV XLPE copper Cable (3cx95m2) for single ckt. for station transformer
150
-
-
... More
Three phase Termination kit for both end for 33kV XLPE copper Cable (3cx95m2)
2
-
-
... More
220 kV Surge Arrestor
3
-
-
... More
220 kV NCT (450-300/1A)
1
-
-
... More
33 kV Surge Arrestor
3
-
-
... More
33 kV NCT For 220/33kV T/F (2000-1000/5A)
1
-
-
... More
220 kV SF-6 Breaker along with 20% extra SF-6 Gas
1
-
-
... More
220kV Isolator without E/Switch
2
-
-
... More
220 kV Post Insulator
5
-
-
... More
220 kV CT for Transformer (450-300/0.577-1-1-1-1A)
3
-
-
... More
220kV C&R Panels
Transformer protection & Ckt breaker control Panel (without auto reclose ) (for both HV & LV side of 220/33kV T/F)
1
-
-
... More
200KVA 33/0.4kV Station T/F
1
-
-
... More
Stainless Steel MK (300TB)
1
-
-
... More
21.744 MVAR 33 kV rating Capacitor Bank with 33kV L&E Switch, NCTs and 33kV LA etc. with allied equipments and supporting structures as per technical specification
1
-
-
... More
1.1 kV Copper Control Cable Armoured for 220 kV bays of size 2CX6mm2, 7CX4mm2, 4CX4mm2, 2CX4mm2, 16CX2.5mm2, 10CX2.5mm2, 7CX2.5mm2, 3CX2.5mm2 including Junction box (as per section-6 of copper control cables specifications and Section-7, switchyard erection).
1
-
-
... More
1.1 kV Copper Control Cable Armoured (FRLS type) for 33 kV bays of size 2CX6mm2, 7CX4mm2, 4CX4mm2, 2CX4mm2, 16CX2.5mm2, 10CX2.5mm2, 7CX2.5mm2, 3CX2.5mm2 including Junction box (as per section-6 of copper control cables specifications and Section-7, switchyard erection).
1
-
-
... More
850/1100 Volt 4 core 16 mm2 armoured copper power cable for MLDB and other cable required as per contract for 220kV bays.
1
-
-
... More
850/1100 Volt 4 core 16 mm2 unarmoured copper power cable for MLDB and other cable required as per contract for 33kV bays.
1
-
-
... More
Laying & connection of earthing material with existing earthmat .
1
-
-
... More
Fire Fighting equipments as per section-6 22.5 Kg Capacity FE CO2 type, Trolley Mounted
2
-
-
... More
25 Kg Capacity FE DCP type, Trolley Mounted
2
-
-
... More
2Fire Buckets(12 No.s with stand in one set)
2
-
-
... More
Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area including all accessories, cables etc. as per clause 16.0 of section 7 of the specifications.
4
-
-
... More
Integration of existing substation automation system of 220/132/33 kV voltage levels including hardware (along with transducers) for 01 No. 220 kV bay & 14 No. 33 kV present bays as per scope of work and software (for present bays as well as future bays) along with associated equipment for the bay (bay as defined in the technical specification, sec sub-station automation system) as per technical specification.
1
-
-
... More
Testing of IUM System at NABL accredited lab
1
-
-
... More
Bolted type 220kV Single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connections and suspension clamp sets suitable for single Tarantula conductor.
6
-
-
... More
Bolted type 220kV Single Tension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connections and suspension clamp sets suitable for single Tarantula conductor.
6
-
-
... More
Bolted type 33 kV single tension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connection and tension clamp set suitable for twin Tarantula (string).
6
-
-
... More
Bolted type 33 kV Single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connections and suspension clamp sets suitable for single Tarantula conductor.
3
-
-
... More
Boltless C-Type Wedge connectors matching with conductor size.
1
-
-
... More
Copper lugs glands, PVC ferrules for control cabling.
1
-
-
... More
Fiber cleats, Aluminium clamps, bolts, nuts, washers etc for fixing control cables in trenches
1
-
-
... More
Galvanised iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 150x25x2 mm, 100x25x2 mm and 75x25x2 mm and G.I conduits of 50/100mm diameter from equipment to main trench as per Section-7 for Switchyard erection.
1
-
-
... More
2.5” dia HDD/PVC pipe for 4Cx4mm2 control cable from CT, VT to metering system as per Section-5, Chapter-5.
1
-
-
... More
AAC Tarantula Conductor
1000
-
-
... More
7/3.15 Earthwire
1
-
-
... More
Spacers for Twin Tarantula conductor
1
-
-
... More
U-bolt 20mm dia
1
-
-
... More
Item for associated structure work
Lattice type steel structure for 220 kV Substation HSIIDC Bawal. Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 220/132/33 kV switchyard fabricated from steel conforming to IS: 2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner.
Main S/Stn. Tower and beam
Tower type AT-1
1
-
-
... More
Beam type AB-1
1
-
-
... More
Tower type CT-4
1
-
-
... More
Tower type CT-5
1
-
-
... More
Beam type DD-2
1
-
-
... More
Equipment Supporting Structure
220 kV NCT drg. No. HTD/ST-150
1
-
-
... More
220 kV CT drawing No. HTD/ST-147
3
-
-
... More
220 kV surge arrestor drg.No.HTD/ST-93R
3
-
-
... More
220 kV Bus Post Insulator drawing No. HTD/ST-116
5
-
-
... More
220 kV Isolator/L&E drawing No. HTD/ST-170
2
-
-
... More
33 kV NCT Drg. No. HTD/ST-88 R
1
-
-
... More
33 kV Surge Arrestor Drg. No. HTD/ST-89
3
-
-
... More
Cable Support Structure (to be design by the bidder )for XLPE Cables
33kV
3
-
-
... More
Equipments for maintenance
Portable circuit breaker operation analyzer.
1
-
-
... More
Digital Micro-Ohm meter for contact resistance measurement Ranges (0-100 ohm)
(0-1 milliohm)
(0-1 milliohm)
1
-
-
... More
Dew Point meter
1
-
-
... More
Portable partial discharge monitoring system for GIS.
1
-
-
... More
Digital Earth resistance meter.
1
-
-
... More
5 kV Automated insulation resistance tester.
1
-
-
... More
Earth stick with lead suitable for use in 220/33kV Switchyard
2
-
-
... More
SF-6 Gas filling and evacuating plant
1
-
-
... More
SF-6 Gas leak detector (Portable)
1
-
-
... More
Tools for gas handling
1
-
-
... More
LT DC Leakage detector from control cabinets and LT cables
1
-
-
... More
Common Spares, Maintenance and Testing Tools (33 KV)
SF6 Gas pressure relief devices
3
-
-
... More
Pressure gauges (of each type) along with coupling device
1
-
-
... More
Rubber Gaskets, “ o” Rings and seals for SF6 Gas
1
-
-
... More
Molecular filter for SF6 Gas with filter bags
1
-
-
... More
Density Monitors for SF6 Gas
1
-
-
... More
All types of Control Valves for SF6 Gas
1
-
-
... More
SF6 Gas of total gas requirement 20%
1
-
-
... More
Enclosures, Insulators & main circuit to replace on each phase, any compartment of Busbar or bay
1
-
-
... More
Covers with all accessories necessary to close a compartment in case of dismantling of any part of the enclosure to ensure the sealing of this compartment (as applicable)
For 3 Phase Enclosure
2
-
-
... More
For Single phase enclosure
3
-
-
... More
Locking device to keep the Disconnectors (Isolators) and Earthing switches in close or open position in case of removal of the driving Mechanism
1
-
-
... More
Bus Support insulator of each type for 3 phase/single phase enclosure
1
-
-
... More
Pipe length (Copper or Steel as applicable) for SF6 Circuit of each type
1
-
-
... More
SF6 to air bushing (33 KV of each type & rating)
1
-
-
... More
CIRCUIT BREAKERS (33 KV)
Complete Circuit Breaker pole of each type & rating complete with interrupter, main circuit, enclosure and Marshalling Box with operating mechanism
3
-
-
... More
Fixed, moving and arcing contacts including insulating nozzles, (3 Nos. of each type)
1
-
-
... More
Rubber gaskets, `O' rings and seals for SF6 gas of each type
1
-
-
... More
Trip coil assembly with resistor as applicable, 3 Nos. of each type
2
-
-
... More
Closing coil assembly with resistor as applicable, 3 Nos. of each type
2
-
-
... More
Molecular filter for SF6 gas with filter bags
1
-
-
... More
SF6 Pressure gauge cum switch OR Density monitors and pressure switch as applicable, 3 Nos. of each type
1
-
-
... More
Coupling device for pressure gauge cum switch/ for connecting Gas handling plant, 3 Nos. of each type
1
-
-
... More
Relays, Power contactors, push buttons, timers & MCBs etc of each type & rating
1
-
-
... More
Closing assembly/ valve, 3 Nos. of each type Set
2
-
-
... More
Trip assembly/ valve, 3 Nos. of each type
2
-
-
... More
Auxiliary switch assembly, 3 Nos. of each type
1
-
-
... More
Spring operated closing mechanism, 1 No. of each type, if applicable
1
-
-
... More
Terminal Pad & connectors
1
-
-
... More
Isolators , E/Switch & High Speed E/Switch (33 KV)
Complete set of 3 nos. of single phase / one no. of 3-phase dis-connector including main circuit, enclosure, driving mechanism.
1
-
-
... More
3 nos. of single phase / one no. of 3-phase Earthing switch including main circuit, enclosure, driving mechanism.
1
-
-
... More
Copper contact fingers for dis-connector male & female contact – for one complete (3 phase) dis-connector of each type and rating.
1
-
-
... More
Copper contact fingers for earthing switch male & female contacts, for one complete (3 phase) earthing switch of each type and rating
1
-
-
... More
Open / Close contactor assembly, timers, key interlock for one complete (3 phase) dis-connector and (3 phase) earthing switch of each type and rating
1
-
-
... More
Push button switch.-each type, as applicable
1
-
-
... More
Limit switch and Aux. Switches for complete 3 phase equipment
For isolator
3
-
-
... More
For earth switch
1
-
-
... More
Rotor housing bearing assembly for complete 3 phase equipment
For isolator
2
-
-
... More
For earth switch
1
-
-
... More
Motor with gear assembly for complete 3 phase equipment
For isolator
3
-
-
... More
b) For earth switch
1
-
-
... More
Corona shield rings as applicable
1
-
-
... More
Hinge pins for complete 3 phase equipment
For isolator
3
-
-
... More
For earth switch
1
-
-
... More
Bearings for complete 3 phase equipment For isolator
5
-
-
... More
For earth switch
1
-
-
... More
Interlocking coil with resistors, timers, key interlock for complete 3 phase
1
-
-
... More
Relays, Power contactors, resistors, fuses, push buttons & MCBs
For isolator
3
-
-
... More
For earth switch
1
-
-
... More
Terminal pad and connectors (complete for one 3 phase equipment)
For isolator
2
-
-
... More
For earth switch
1
-
-
... More
Aux. switch assembly (complete) with 10 NO & 10 NC OR more contacts
1
-
-
... More
36 kV, 2500 A, 3 – f or 1 –f high speed fault making grounding switch, Internal parts complete with all necessary gaskets mounting hardware etc.
1
-
-
... More
36 kV, 2500 A, 3 – f or 1 –f high speed fault making grounding switch operating mechanism complete with all necessary gaskets connecting apparatus.
1
-
-
... More
Current Transformer (33kV)
33kV 1 ph CT ratio 2000-1000-/0.577-5-5-1A complete with all gaskets and mounting hardware
3
-
-
... More
33kV 1 ph CT ratio 400-300-/5-1A (line CT) complete with all gaskets and mounting hardware
6
-
-
... More
Voltage Transformer/PT(33kV)
33kV, 1-phase VT as per technical specifications complete with all gaskets and mounting hardware.
1
-
-
... More
Civil works
BREAKER FOUNDATION
Design, engineering, supply of labour, material for construction of breaker foundations including all associated works such as PCC, RCC, structural steel, steel reinforcement, form work etc. or any other items not specifically mentioned herein but required for completion of work as per approved equipment(s) and technical specifications.Surplus earth, if any shall be disposed of to a suitable undisputed place outside the substation without any extra cost.
220kV, SF-6 Breaker
1
-
-
... More
TRANSFORMER FOUNDATION
Design, engineering, supply of labour, material for Construction of transformer radiator foundation including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for completion of work as per technical specifications & drawing attached. In case extra foundation(s) has/have to be constructed (as per approved T/F drawing) to complete the job, nothing extra would be paid on this count.Surplus earth, if any shall be disposed of to a suitable undisputed place outside the substation without any extra cost.
100MVA 220/33kV T/F radiator foundation.
1
-
-
... More
CABLE TRENCHES
Supply of labour, material such as cement, Reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works approved Trench layout plan, HVPNL drgs. & tech. specs. complete in all respect.Surplus earth, if any shall be disposed of to a suitable undisputed place outside the substation without any extra cost.
1
-
-
... More
SITE SURFACING
Providing, supplying & laying two layers of uncrushed/crushed/broken stone/ pebbles gravel fill. The first layer after compaction shall make min. 50mm thickness course/layer of 40mm nominal size, including dressing, rolling & compaction complete as per specs., GELO and instructions of XEN/CWD.Surplus earth, if any shall be disposed of to a suitable undisputed place outside the substation without any extra cost.
1150
-
-